Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Ejection fraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

Cardiovascular features of heart failure with preserved ejection fraction versus nonfailing hypertensive left ventricular hypertrophy in the urban Baltimore community: the role of atrial remodeling/dysfunction.

OBJECTIVES: The purpose of this study was to identify cardiovascular features of patients with heart failure with preserved ejection fraction (HFpEF) that differ from those in individuals with hypertensive left ventricular hypertrophy (HLVH) of similar age, gender, and racial background but without failure. BACKGROUND: Heart failure with preserved ejection fraction often develops in HLVH patients and involves multiple abnormalities. Clarification of changes most specific to HFpEF may help elucidate underlying pathophysiology. METHODS: A cross-sectional study comparing HFpEF patients (n = 37), HLVH subjects without HF (n = 40), and normotensive control subjects without LVH (n = 56). All subjects had an EF of >50%, sinus rhythm, and insignificant valvular or active ischemic disease, and groups were matched for age, gender, and ethnicity. Comprehensive echo-Doppler and pressure analysis was performed. RESULTS: The HFpEF patients were predominantly African-American women with hypertension, LVH, and obesity. They had vascular and systolic-ventricular stiffening and abnormal diastolic function compared with the control subjects. However, most of these parameters either individually or combined were similarly abnormal in the HLVH group and poorly distinguished between these groups. The HFpEF group had quantitatively greater concentric LVH and estimated mean pulmonary artery wedge pressure (20 mm Hg vs. 16 mm Hg) and shorter isovolumic relaxation time than the HLVH group. They also had left atrial dilation/dysfunction unlike in HLVH and greater total epicardial volume. The product of LV mass index and maximal left atrial (LA) volume best identified HFpEF patients (84% sensitivity, 82% specificity). CONCLUSIONS: In an urban, principally African American, cohort, HFpEF patients share many abnormalities of systolic, diastolic, and vascular function with nonfailing HLVH subjects but display accentuated LVH and LA dilation/failure. These latter factors may help clarify pathophysiology and define an important HFpEF population for clinical trials.

Age Distribution↗

Effect of propranolol versus no propranolol on total mortality plus nonfatal myocardial infarction in older patients with prior myocardial infarction, congestive heart failure, and left ventricular ejection fraction > or = 40% treated with diuretics plus angiotensin-converting enzyme inhibitors.

At 32-month follow-up of older patients with prior myocardial infarction, congestive heart failure, and a left ventricular ejection fraction > or = 40% treated with diuretics plus angiotensin-converting enzyme inhibitors, and also with digoxin if atrial fibrillation was present, propranolol caused a 35% significant reduction in total mortality and a 37% significant decrease in total mortality plus nonfatal myocardial infarction compared with no propranolol. At 1-year follow-up, propranolol caused a significantly greater increase in left ventricular ejection fraction (6%) and a significantly greater reduction in left ventricular mass (34 g) than did no propranolol (2% and 20 g, respectively).

Adrenergic beta-Antagonists↗

Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic-gated 99mTc-tetrofosmin myocardial SPECT.

UNLABELLED: We compared the left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) as calculated by Cedars automated quantitative gated SPECT (QGS) to those determined by first-pass radionuclide angiography (FPRNA) and contrast left ventriculography (LVG) in a group of 21 patients (mean age 61.4 +/- 9.2 y). METHODS: A total of 740 MBq 99mTc-tetrofosmin was administered rapidly into the right cubital vein at rest, and FPRNA was performed using a multicrystal gamma camera. One hour after injection, QGS was performed with a temporal resolution of 10 frames per R-R interval. LVG was performed within 2 wk. RESULTS: The EDV, ESV and LVEF calculated by QGS were highly reproducible (intraobserver, r = 0.99, r = 0.99 and r = 0.99, respectively; interobserver, r = 0.99, r = 0.99 and r = 0.99, respectively; P < 0.01) and were more consistent than those determined by FPRNA (intraobserver, r = 0.97, r = 0.95 and r = 0.93, respectively; interobserver, r = 0.86, r = 0.96 and r = 0.91, respectively; P < 0.01). There was a good correlation between EDV, ESV and LVEF by FPRNA and those by LVG (r = 0.61, r = 0.72 and r = 0.91, respectively; P < 0.01), and there was an excellent correlation between QGS and LVG (r = 0.73, r = 0.83 and r = 0.87, respectively; P < 0.01). The mean EDV by QGS (100 +/- 11.3 mL) was significantly lower than by FPRNA (132 +/- 16.8 mL) or LVG (130 +/- 8.1 mL), and the mean ESV by QGS (53.8 +/- 9.3 mL) was lower than by FPRNA (73.0 +/- 13.3 mL). Ejection fraction values were highest by LVG (57.1% +/- 3.2%), then QGS (51.8% +/- 3.0%) and FPRNA (48.9% +/- 2.4%). CONCLUSION: QGS gave more reproducible results than FPRNA. LV volumes and LVEF calculated by QGS correlated well to those by LVG.

Adult↗

Comparison of fully automated and manual ejection fraction calculations: validation and pitfalls.

Resting multigated blood-pool studies were performed on 61 patients without arrhythmias and data were simultaneously acquired to two computer systems. Using one computer, manual ejection fraction (EF) was calculated by two trained observers. EF was also calculated from the other computer using a commercially available fully automated program; quality control (QC) images were routinely obtained to evaluate correct left-ventricular center location, background region assignment, or gross edge mispositioning. When errors were noted, the automated analysis was reprocessed with operator intervention. Forty-eight of the 61 studies (78%) produced adequate QC images. Operator redefinition of the left ventricular center and background of the 13 QC failures raised the automated success level to 92%. Correlation of the manual EF by two observers was excellent (r = 0.969). The automated EF measurements correlated well with the average observer's (r = 0.898). An improved version of software reduced the QC failures from 13 to 10. Operator assisted automated processing gave the success rate of 94%. The remaining 6% of patients required manual processing to obtain a correct ejection fraction. Our normal range for manual EF is greater than or equal to 0.50 and our corresponding normal range for this group of patients using the automated program was greater than or equal to 0.44. Based on greater than or equal to 0.44, four patients with a low manual EF had a normal automated EF. All four patients had cardiac disease but there was no evidence of abnormal cardiac function. The fully automated program provided good correlation with manual EF and can remove some of the subjectivity in manual edge determination. However, QC images must be carefully examined and the normal EF range for the automated program must be determined.

Adult↗

Comparison of two-dimensional echocardiographic tissue harmonic imaging and gated sestamibi single-photon emission computed tomographic left ventricular ejection fraction measurements.

There was good correlation between left ventricular ejection fraction (EF) measurements employing 2-dimensional echocardiography with tissue harmonic imaging and single-photon emission computed tomography using quantitative gated scintigraphy, although in most patients, echocardiographic EF was lower. There was a high degree of agreement between these 2 techniques in assignment of EF to the categories of normal, mildly, moderately, or severely decreased. However, when EF categories did differ, echocardiography always resulted in assignment to a lower category.

Aged↗

Automation of gated tomographic left ventricular ejection fraction.

BACKGROUND: The feasibility of determining left ventricular (LV) ejection fraction (EF) from 99mTc-labeled sestamibi gated tomography (GSPECT) is well established. To improve precision of measurement, rules used by observers in processing tomograms were encoded for automation. METHODS AND RESULTS: LV centers were estimated from activity centroids of time-difference images exceeding 50% of maximum counts. End diastole and end systole were defined by time-varying maximum count extremes. Endocardial borders were generated by fitting maximum locations with fifth-order two-dimensional harmonics, searching inward to predetermined thresholds, and reconciling endocardial with valve plane points. Regression analysis of GSPECT EF yielded r = 0.87 versus equilibrium gated blood pool in 75 patients and r = 0.87 versus gated first pass in 65 patients. GSPECT EF interobserver variability was r = 0.92 and intraobserver automatic versus manual linear correlation was r = 0.94. A subgroup of 25 studies was analyzed by six independent observers, for whom EF agreement with the core laboratory ranged from r = 0.93 to r = 0.96. Experienced observers judged it necessary to alter end-diastolic or end-systolic frames in 7% of patients, endocardial borders in 14%, and LV centers in 28%. CONCLUSION: Results of automated GSPECT LV EF correlated well with those of manual GSPECT and gated first-pass and equilibrium blood pool values and were highly reproducible.

Algorithms↗

In vivo stability of in vitro labelled 99Tcm-red blood cells for radionuclide determination of left ventricular ejection fractions and volumes.

Serial determination of radionuclide left ventricular ejection fraction and volumes require a label that remains highly stable after introduction into the human circulation. We have evaluated the in vivo stability of 99Tcm-red blood cells (99Tcm-RBC) labelled in vitro by preparation with small amounts of a stannous agent in 19 patients with coronary artery disease. The distribution volume of 99Tcm-RBC was virtually identical to that of RBC labelled with 51Cr. Labelling efficiency expressed as the cell bound/total activity was more than 95% and remained high throughout 1 h after injection of the label. The effective in vivo half-times (T1/2) calculated from venous blood activity and externally recorded left ventricular end-diastolic frame activity were 342 +/- 103 min (mean +/- S.D.) and 306 +/- 92 min, respectively. A significant correlation, r = 0.86 (p less than 0.01) was found between the T1/2 values calculated from the two methods. Thus, a high in vivo stability of the label was demonstrated with considerable inter-patient variation. The labelling procedure seems suitable for serial performance of radionuclide cardiography within an hour after injection of 99Tcm-RBC. However, serial volume determination necessitates individual calculation of in vivo tracer decay from either venous blood or externally recorded activity in the left ventricular area during steady conditions.

Aged↗

Royal College Lecture, 1976. Preoperative left ventricular ejection fraction and survival after coronary artery surgery.

A preoperative ejection fraction (EF) of less than 0.30 slightly increases the immediate risk of myocardial revascularization. This risk can be greatly reduced by better myocardial protection and complete revascularization of the coronary lesions during surgery. Poor ventricular function, however, greatly influences the patient's long-term survival, especially when the EF is less than 0.30. In patients with coronary artery disease, in whom there are clinical and angiographic indications of an aortocoronary shunt and the EF, when measured in the right anterior oblique plane, is equal to or greater than 0.30, surgery may be performed with an acceptable surgical risk (3.9%) and satisfactory long-term (4- to 5-yr) survival (85%). When the EF is less than 0.30 it is necessary (before refusing operation) to conduct additional studies of venticular function such as biplane ventriculography, venticulography following the administration of nitroglycerin, epinephrine or after an artificially induced extrasystole. Isotope studies may also be considered, as they can reveal the presence of viable myocardial cells in the hypo- or akinetic segments.

Cardiac Output↗

Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction.

UNLABELLED: The combination of myocardial perfusion and poststress ejection fraction (EF) provides incremental prognostic information. This study assessed predictors of nonfatal myocardial infarction (MI) versus cardiac death (CD) by gated myocardial SPECT and examined the value of integrating the amount of ischemia and poststress EF data in risk stratification. METHODS: We identified 2,686 patients who underwent resting (201)Tl/stress (99m)Tc-sestamibi gated SPECT and were monitored for >1 y. Patients who underwent revascularization < or = 60 d after the nuclear test were censored from the prognostic analysis. Visual scoring of perfusion images used 20 segments and a scale of 0--4. Poststress EF was automatically generated. RESULTS: Cox regression analysis showed that after adjusting for prescan data, the most powerful predictor of CD was poststress EF, whereas the best predictor of MI was the amount of ischemia (summed difference score [SDS]). Integration of the EF and SDS yielded effective stratification of patients into low-, intermediate-, and high-risk subgroups. Patients with EF >50% and a large amount of ischemia were at intermediate risk (2%--3%), whereas those with mild or moderate ischemia were at low risk of CD (<1%/y). Patients with EF between 30% and 50% were at intermediate risk even in the presence of only mild or moderate ischemia. In patients with EF <30%, the CD rate was high (>4%/y) irrespective of the amount of ischemia. CONCLUSION: Poststress EF is the best predictor of CD, whereas the amount of ischemia is the best predictor of nonfatal MI. Integration of perfusion and function data improves stratification of patients into low, intermediate, and high risk of CD.

Adenosine↗

[Clinical significance of right ventricular ejection fraction in cases with atrial septal defect].

Right ventricular ejection fraction (RVEF) assessed by cardiac radionuclide angiography has been applied to evaluate right ventricular function such as ischemic, valvular and congenital heart disease. Using this modality, previous reports also suggest that there is good correlation between RVEF and mean pulmonary arterial pressure (mPA) from catheterization findings in mitral valvular disease and chronic obstructive lung disease. In this study, cardiac RI angiography were performed on 33 adult patients with atrial septal defect (ASD), RVEF is not so good correlation (r = -0.42) with mPA, but in cases within pulmonary to systemic ratio (Qp/Qs) less than 2.0 limits, there is good correlation between RVEF and mPA (n = 9, r = -0.71). As a conclusion, in ASD, both afterload assessed by mPA and preload assessed by Qp/Qs decrease RVEF.

Adult↗

Multiple-hospital survey of ejection-fraction variability using a cardiac phantom.

A dynamic cardiac phantom was used to provide identical input data at 11 different nuclear medicine laboratories throughout the Philadelphia area, and the variability in the resulting calculations of ejection fraction (EF) was assessed. The variability observed between different operators using the same computer system averaged 3 EF units, which was similar to that between different observers using different types of computers. In the range of low ejection fractions, however, there was a suggestion that EFs calculated with an MDS computer were slightly lower than those from a DEC computer.

Cardiac Output↗

[Regional ejection fractions to determine left ventricular function. Comparison of first-radionuclide-pass and equilibrium-radionuclide-ventriculography with the results of cineventriculography].

An analysis of regional left ventricular pump function by regional ejection fractions (rAF) may be done employing First Pass techniques or Equilibrium Radionuclide Ventriculography (MUGA). The ventricle was intersected orthogonally into 5 divisions. This technique was applied to 15 hearts with regular wall motion and to 26 hearts with wall motion abnormalities. The discrimination for wall motion abnormalities of the anterior wall by MUGA was better than using steps of asynergy (normo-, hypo-, dys- and asynergy). With rAF, decrease of regional pump function could be detected (10% of the investigated hearts) even when there was a regular global ejection fraction. Due to the different projection angles for First Pass and MUGA (app. 70 degrees difference), correlation coefficients for anatomically similar divisions of the left ventricle, assessed with both techniques (n = 41) were rather low with the exception of the section belonging to the apex. Assessing the wall motion of the posterior wall, with MUGA isolated wall motion abnormalities could be detected only in 2 out of 6 cases. With First Pass, wall motion abnormalities could be detected in all cases. Therefore, to determine motion and function of the posterior wall, First Pass or even better First Pass and MUGA should be employed since the latter case, the ventricle may be evaluated from two projections in one examination only.

Cardiac Output↗

Effects of reperfusion on left ventricular ejection fraction and volume after acute myocardial infarction.

The effects of reperfusion on left ventricular (LV) function and volume were studied in patients with evolving acute myocardial infarction (AMI). We analyzed the LV ejection fraction and volume in patients who had been admitted within 24 h of the onset of their first AMI with culprit lesion of #6, #7 and #1 (American Heart Association classification). Sixty-five patients (Re group) received successful reperfusion therapy within 6 h after the AMI. The other 60 patients (Oc group), who were admitted from 6 to 24 h after the AMI, received conservative therapy. Patients with re-obstruction of the culprit lesion after reperfusion therapy were excluded from the Re group. Patients with spontaneous recanalization following conservative therapy were excluded from the Oc group. The LV ejection fraction (LVEF), LV end-systolic volume index (LVESVI), and LV end-diastolic volume index (LVEDVI) were measured using a modified Dodge's formula by left ventriculography performed 4 weeks after the AMI. LVEF in the Re group was significantly greater than in the Oc group (57 +/- 12 vs 49 +/- 11%) (mean +/- SD, p less than 0.01). LVESVI in the Re group was significantly smaller than in the Oc group (30 +/- 13 vs 38 +/- 16 ml/m2, p less than 0.01). Although LVEDVI was not significantly different between the 2 groups, in patients with a responsible coronary lesion of segment #6, LVEDVI in the Re group was significantly smaller than in the Oc group (67 +/- 14 vs 77 +/- 18 ml/m2, p less than 0.05). Although LVEF and LV volume correlated in both groups, the correlation was weak (r = 0.40-0.42), suggesting that LV volume was not dependent solely on LV functional recovery. The incidence of ventricular aneurysm in the Re group was significantly lower than in the Oc group (15.4 vs 45.0%, p less than 0.01). Multivariate analysis selected reperfusion of the responsible coronary artery as one of the factors significantly associated with a reduction of LVEDVI, LVESVI, an improvement of LVEF, and a decrease in the rate of aneurysm formation. In summary, our results indicated that reperfusion improved EF, reduced LV volume, and decreased the rate of aneurysm formation as compared to non-reperfusion, which suggests that reperfusion therapy is beneficial for both functional recovery and ventricular remodeling.

Adult↗

Late potentials and ejection fraction at hospital discharge: prognostic value in thrombolyzed and non-thrombolyzed patients. A preliminary report. The Belgian Working Group for Signal Averaging.

The prognostic value of the use of thrombolytic therapy (TL), the ejection fraction (EF) and the presence of late potentials (LP) in the signal-averaged ECG (filter less than 40 Hz) at the time of hospital discharge was assessed in a multicenter prospective study. This report presents the follow-up at 4 months of the first 263 patients. Thrombolytic therapy was given to 41%. The mean ejection fraction was 45%. The average duration of the high frequency QRS complex (HFQRS) was 104 ms. The mean duration of the terminal signal under 40 microV (D40) was 31 ms. The combination of both HFQRS greater than 110 ms and a D40 greater than 40 ms was considered as presence of LP. The cardiac mortality at 4 months was 5.7% (15 patients). Late ventricular tachycardia or fibrillation occurred in 2.3% (6 patients). The relative risk (RR) for cardiac death or late events was 5.14 with a 95% confidence interval (CI) of 1.2 to 22.0 when no thrombolytic therapy was used. The RR was 3.39 (CI: 1.4 to 8.4) for patients with an EF lower than 30%. The single most important electrocardiographic parameter was a D40 greater than 40 ms (RR: 3.14, CI: 1.3 to 7.8). The presence of LP had a RR of 4.28 (CI: 1.7 to 10.5). With stepwise regression analysis it was evident that cardiac function and information obtained by signal averaging offered independent prognostic information. The presence of LP at hospital discharge after acute infarction offers additional prognostic information to EF for the risk of later cardiac death, especially in patients without thrombolysis.

Aged↗

Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: a comparison with magnetic resonance imaging.

OBJECTIVES: We evaluated the accuracy and reproducibility of contrast echocardiography versus tissue harmonic imaging for measurements of left ventricular (LV) volumes and ejection fraction (EF) compared to magnetic resonance imaging (MRI). METHODS: Digital echo recordings of apical LV views before and after intravenous contrast were collected from 110 consecutive patients. Magnetic resonance imaging of multiple short-axis LV sections was performed with a 1.5-T scanner. Left ventricular volumes and EF were calculated offline by method of discs. Thirty randomly selected patients were reanalyzed for intraobserver and interobserver variability. RESULTS: Compared with baseline, contrast echo increased feasibility for single-plane and biplane volume analysis from 87% to 100% and from 79% to 95%, respectively. The Bland-Altman analysis demonstrated volume underestimation by echo, but much less pronounced with contrast. Limits of agreement between echo and MRI narrowed significantly with contrast: from -18.1% to 8.3% to -7.7% to 4.1% (EF), from -98.2 to -11.7 ml to -59.0 to 10.7 ml (end-diastolic volume), and from -58.8 to 21.8 ml to -38.6 to 23.9 ml (end-systolic volume). Ejection fraction from precontrast echo and MRI differed by > or =10% (EF units) in 23 patients versus 0 after contrast (p < 0.001). At intraobserver and interobserver analysis, limits of agreement for EF narrowed significantly with contrast. CONCLUSIONS: The two-dimensional echocardiographic evaluation of LV volumes and EF in non-selected cardiac patients was found to be more accurate and reproducible when adding an intravenous contrast agent.

Adult↗

Detection of early abnormalities of left ventricular function by hemodynamic, echo-tissue Doppler imaging, and mitral Doppler flow techniques in patients with coronary artery disease and normal ejection fraction.

We have investigated the possibility of detecting early abnormalities of left ventricular function at the initial phase of ischemic cardiomyopathy. Sixteen normotensive patients with coronary artery disease and normal left ventricular ejection fraction and 6 control patients were studied by invasive hemodynamic techniques in combination with transmitral Doppler flow or with echo-tissue Doppler imaging. The extent of the percentage of left ventricular longitudinal shortening and the systolic peak velocity at echo-tissue Doppler were significantly higher in the control patients than in patients with ischemic cardiomyopathy (P <.01). Left ventricular end-diastolic pressure was higher (P <.05), whereas mean values of isovolumic contraction and relaxation indexes (dP/dt/P: P <.05; +dP/dt: P <.05; -dP/dt: P <.01) were lower in patients with ischemic cardiomyopathy. Tau was significantly longer in ischemic patients (42.7 +/- 8.8 versus 34.5 +/- 3.7 ms, P <.05). In the control patients, the aortic valve closure to peak E interval by transmitral Doppler flow was significantly longer than that measured by echo-tissue Doppler (P <.001), whereas in patients with ischemic cardiomyopathy, this interval difference was still present and significantly shorter (P <.05). In patients with coronary artery disease and normal ejection fraction, minor and early abnormalities of left ventricular function related to isovolumic contraction and relaxation as well as to longitudinal shortening could be detected. In addition, a suction-like effect, detected during early filling evaluation with echo-tissue Doppler, is significantly decreased but not abolished during the early stages of coronary artery disease.

Adult↗

Clinical assessment of left ventricular regional contraction patterns and ejection fraction by high-resolution gated scintigraphy.

An improved, noninvasive, radionuclidic, gated blood-pool imaging technique has been developed for clinical analysis of regional contraction abnormalities of the left ventricle and determination of ejection fraction. The principal innovations include high-resolution collimation, higher information density, improved method for dynamic aortic-mitral-diaphragmatic border delineation, accurate selection of the endsystolic gating interval through the use of the phonocardiogram, and accurate end-diastole by on-line gating immediately following the electrocardiographic QRS. The results of scintigraphic studies were compared with selective radiopaque cineangiographic findings in 27 patients with cardiac disease; excellent correlations of ejection fractions (r = 0.93) and abnormal contraction patterns (17/17 patients) were demonstrated. In addition, the clinical usefulness in evaluating ventricular performance was demonstrated in 79 patients with acute and chronic coronary artery disease. This radionuclidic technique allowed assessment of reversibility of segmental dyssynergy by the response to nitroglycerin in 20 patients. These findings demonstrate the validity of this improved radionuclidic technique in the atraumatic quantification of ventricular function and suggest its usefulness in a variety of clinical conditions.

Acute Disease↗