Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ELECTRICITY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

The importance of restoration of the atmospheric electrical environment in closed Bioregenerative Life Supporting Systems.

Earth based Bioregenerative Life Supporting Systems (BLSS) are subject to 4 main physical factors: gravity, light, temperature and electrical environment. The first 3 are obvious to everyone, the Electrical Environment (EE) is not under the majority of prevailing conditions perceived directly by our senses. The EE is one of the important physical factors directly influencing some plants and in a less obvious way also the majority of plants. There are only two long range forces in nature: the electromagnetic and the gravitational forces. Gravity is very much weaker than the electromagnetic forces FG/FEL=10(-38), where FG is the gravitational Force and FEL are the electromagnetic Forces. The atmospheric electric field prevails all the time over the entire Earth with a mean intensity of 130 V/m. It is therefore a potent factor which may be used by some plants exposed throughout their entire life time to the atmospheric electric field. What effect should the normal atmospheric electric field have on plants? All living plants are good electrical conductors for electrostatic fields. The plants distort the normally vertical field lines, which have to be perpendicular to the plant tissue everywhere in order to avoid the extraction of energy from the field. The meristems concentrate the field lines, thus the electrically charged nutrients are supplied to the growing parts of the plant exposed to the field. This results in electrotropism in some plants. It is very well known that plants do have adaptive capabilities as compared to animals, it is important for their survival, because they cannot run away from trouble. It is found by careful observations of the behaviour of different plants that some plants do respond to the presence of the atmospheric electric field while other plants exposed to the same environment are indifferent to the atmospheric electric field. The plants growing in the Biosphere II were shielded by the metal structure of the Biosphere II. Because these plants which do make use of the atmospheric electric field are also to be found in the Biosphere II and must be deprived of this natural atmospheric electric field and in consequence of some of their natural nutrients. I have experimental evidence that at least some plants do respond to the atmospheric electric field. This effect is the most likely cause of the oxygen depletion and of the carbon dioxide accumulation in Biosphere II. Under the micro gravity encountered in space habitats the restoration of electric fields is even more important for plant growth than it is on the Earth.

Ecological Systems, Closed↗

Basic study of new diagnostic modality according to non-invasive measurement of the electrical conductivity of tissues.

The purposes of this study were to estimate the electrical conductivity of tissues by non-invasively measuring the electrical bio-impedance, to develop a new method for tissue diagnosis, i.e., electrical impedance tomography (EIT). Tissue models were first designed taking into consideration the distribution of the fat tissue, muscle and bone in the human forearm, and then the intra-tissue distributions of electrical potential and field, and the electrical impedance in the models was theoretically analyzed by the three-dimensional finite element method. The electrical impedance of both forearms was measured in healthy human subjects, and estimated the electrical conductivity of individual local tissues. The results of the analysis showed that the distributions of electrical potential and field were affected by the presence of fat tissue but not by the presence or absence of bone. In addition, as a result of calculation of the electrical resistance of the extracellular fluid (Re) in each model, it was found that the value of bio-impedance was influenced by the presence of fat tissue, and the value of bio-impedance was increased by the intervention of a fat layer. The electrical conductivity estimated by fitting the observed values to the values obtained by finite element analysis was 0.40 S/m and 0.15 S/m for male muscle and fat tissue, and 0.35 S/m and 0.11 S/m for female muscle and fat tissue, respectively. The sex difference in the slope of linear approximation in the estimation of electrical conductivity of the males and females was thought to be due to sex differences in the properties and structure of fat tissue. These results suggest that local tissues can be diagnosed differentially and electrically by percutaneous measurement of local bio-impedance and subsequent estimation of the electrical conductivity of each tissue.

Adult↗

Cardiac electrical stunning is a common feature of cardiac arrhythmias.

There are many published papers focused on the topic of atrial electrical remodeling, which defined as the shortening and dispersion of effective refractory period (ERP) in patients with paroxysmal or persistent tachyarrhythmias or in animals with long-term rapid atrial pacing. Heart failure could produce the electrical remodeling of sinus node, manifesting the prolongation of corrected sinus node recovery time and sinus cycle length. It might be attributed to decreased hyperpolarization-activated cyclic nucleotide expression of sinus node. Rapid atrial pacing for only 10-15 min, simulating transient atrial tachyarrhythmias, alters sinus node function in human. Termination of atrial flutter by ablation induces reversible changes in sinus node function. After atrial fibrillation (AF) ablation, there was a significant improvement of sinus node function, with an increase in the mean heart rate, maximal heart rate and heart rate range significantly. Reverse electrical remodeling of the ERP occurs at different rates in different regions of the atrium. Previous experiments showed that electrical remodeling of atrial myocardium could be induced by autonomic nervous transmitters and suggested that autonomic nerve activity was an important factor to promote AF episodes. We postulated that electrical remodeling and reverse electrical remodeling are common features of the heart, including atrium, ventricle, sinus node, and conductive system. Inappropriate very rapid or slow electrical depolarization may cause electrical remodeling of the heart, but appropriate rates of electrical depolarization and cessation of rapid stimulation may contribute to the reverse electrical remodeling. So, we forward that a concept defined as cardiac electrical stunning, including electrical remodeling and reverse electrical remodeling, should be a common characteristic and mechanism of cardiac arrhythmias.

Animals↗

Modern concepts of treatment and prevention of electrical burns.

Electric injuries account for 1,000 deaths in the United States, with a mortality rate of 3--15%. As the widespread use of electricity and injuries from it increase, all health professionals involved in burn care must appreciate its physiological and pathological effects as well as management of electrical current injury. Electric current exists in two forms: alternating current and direct current. The effects of electricity on the body are determined by seven factors: (1) type of current, (2) amount of current, (3) pathway of current, (4) duration of current, (5) area of contact, (6) resistance of the body, and (7) voltage. Electrical accidents can be divided into less than 1,000 V (low-voltage accidents) and greater than 1,000 V (high-voltage accidents). In any electrical accident, the witness must turn off the power source and initiate treatment at the scene of the injury. Low-voltage electric burns almost exclusively involve either the hands or oral cavity. Surgical treatment will vary with the severity of the injury. Burns caused by contact with a high-voltage alternating electric circuit conforms to two types: burns from an electric arc and burns from an electric current. High-voltage electric current injuries have a wide variety of systemic manifestations, including neurologic complications, cardiovascular and pulmonary manifestations, vascular damage, and abdominal, bone, eye and joint complications. An organized approach to the management of these complications is outlined in this article. The best treatment of burn injuries remains prevention. Because the majority of burn injuries are due to occupational electrical injuries, the regional burn centers must work effectively with industry to prevent these potentially life-threatening accidents.

Anti-Bacterial Agents↗

[A study on expression of caspase-8 in organs of rats after electrical injury at antemortem or postmortem].

OBJECTIVE: This study was conducted to detect the expression of caspase-8 in organs of rats after The electrical injury so as to elucidate whether caspase-8 is useful in identifying electrical lesion. METHODS: experiment included two parts. In the first part (the antemortem electrical injury part), thirty-five healthy male SD rats were randomly divided into seven groups (n = 5 per group), i. e. the group of rats subjected to instantaneous electrothanasia; the groups of rats subjected to cervical dislocation at 1 h, 2 h, 4 h, 8 h after electrical injury; the sham group and the normal control group. In the second part (the postmortem electrical injury part), twenty-five healthy male SD rats wererandomly divided into five groups (n=5 per group), i. e. the groups of rats electrically injured just after death, and at 15 min, 30 min, 60 min after death; and the postmortem sham group. All experimental rats were given respectively an electric shock with two metal clamps that were connected with two poles of 220 V alternating current by clamping the rats' left hind limbs and right forelimbs. The rats of sham group after death were clamped but not electrified. The brain, lung, heart, liver, spleen, kidney, the muscle of electrified limb, the cutis of electrified limb of all experimental rats and those organs of control groups were dissected to detect the expression of caspase-8 by immunohistochemistry staining, and the staining intensities were assessed by image analysis system. RESULTS: In the antemortem electrical injury groups, the expression of caspase-8 was positive in brain, heart, liver and kidney; the strongest staining intensity appeard at 4 h after electrical injury and decreased at 8 h after electrical injury. In the group of rats electrically injuryed just after death, the expression of caspase-8 was faint, and the expression of caspase-8 in spleen, lung, muscle and cutis was negative in the other groups. The expression of caspase-8 in all detected organs was negative in the other rats that were electrified after death. CONCLUSION: Caspase-8 can be regarded as an index in identifying electrical injury and distinguishing between antemortem and postmortem electrical injuryies.

Animals↗

Electrical stimulation at traditional acupuncture sites in periphery produces brain opioid-receptor-mediated antinociception in rats.

Previous studies in rats measuring latency to tail flick with radiant heat have shown that the antinociceptive effect induced by electrical stimulation of different frequencies at traditional acupuncture sites is mediated via different opioid receptors in the spinal cord. The present study was designed to observe (1) whether electrical stimulation at such sites could produce antinociceptive effects in the cold water tail-flick (CWT) test; (2) whether the antinociceptive effects could be blocked by s.c. injection of the opioid receptor antagonist naloxone and (3) whether i.c.v. injection of selective antagonists for mu (cyclic D-Phe-Cys-Tyr-D-Trp-Arg-Thr-Pen-Thr-NH2, CTAP), delta (naltrindole) or kappa (nor-binaltorphimine) opioid receptors would block the antinociceptive effect produced by electrical stimulation. Sprague-Dawley rats were stimulated at frequencies of 2, 30 or 100 Hz with acupuncture needles inserted into acupoints Zusanli and Sanyinjiao in the hind leg for 30 min. Antinociception was assayed in the CWT. The results showed that (1) a significant, frequency-related increase in threshold in the CWT was observed in all electrical stimulation groups as compared with the placebo group and the antinociceptive effect lasted about 30 min poststimulation; (2) naloxone (s.c.) antagonized the antinociceptive effect induced by 2 Hz, 30 Hz or 100 Hz electrical stimulation and (3) either CTAP or naltrindole (i.c.v.) almost completely blocked the antinociceptive effect induced by 2 Hz or 30 Hz electrical stimulation, but was less effective in blocking antinociception induced by 100 Hz electrical stimulation; nor-binaltorphimine (i.c.v.) greatly reduced antinociception induced by 30 Hz or 100 Hz electrical stimulation, but not by 2 Hz electrical stimulation. These results indicate that the antinociception induced by 2 Hz electrical stimulation is mediated by both mu and delta opioid receptors; the antinociception induced by 100 Hz electrical stimulation is mediated primarily by the kappa receptor; and the antinociception induced by 30 Hz electrical stimulation is mediated by all three opioid receptor types. Thus, the antinociceptive effect induced by peripheral electrical stimulation, as measured by the CWT, involves opioid receptors in the rat brain.

Acupuncture Therapy↗

Effect of electric load impedances on the performance of sandwich piezoelectric transducers.

Based on the electromechanical equivalent circuit, the sandwich piezoelectric transducer with adjustable resonance frequency is studied. The underlying theory of frequency adjustment is its piezoelectric effect. In this paper, the influence of electric load impedance (including electric resistance, electric inductance, and electric capacitance) on the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient is analyzed theoretically and experimentally. It is demonstrated that the electric load impedance can change the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient. When the electric load resistance is increased, the resonance frequency and the antiresonance frequency are increased; the effective electromechanical coupling coefficient has a maximum value when the electric load resistance changes. When the electric load resistance becomes large, the effect of the electric load resistance on the effective electromechanical coupling coefficient is negligible. When the electric load inductance is increased, the resonance frequency and the antiresonance frequency are decreased, whereas the effective electromechanical coupling coefficient is increased. When the electric load capacitance is increased, the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient are all decreased. It should be noted that when the electric load impedance becomes large, the effect of the electric load impedance on the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient of a sandwich piezoelectric transducer becomes negligible.

Journal Article↗

Effects of preventing reinnervation on axotomized spinal motoneurons in the cat. I. Motoneuron electrical properties.

1. The intent of this study was to determine the effect on the electrical properties of axotomized spinal motoneurons when motor axons are allowed to regenerate but are denied the opportunity to reinnervate muscle. 2. The nerve supplying the medial gastrocnemius (MG) muscle in cats was served close to its entry into the muscle and sutured onto the surface of the lateral gastrocnemius (LG) muscle. The MG muscle was excised to prevent availability of vacant end-plates to the regenerating MG axons. The electrical properties of antidromically identified MG motoneurons were studied using intracellular recording at various postoperative intervals. 3. In 9 of 12 experimental animals, no sign of functional innervation by MG axons of the LG muscle could be detected. In three experimental animals, electrical and contraction activity in the LG muscle was observed following electrical stimulation of the transplanted MG nerve. The observed electrical and contraction activity was, however, negligible compared to the effects of electrical stimulation of the intact LG-soleus nerve. 4. At the earliest postoperative interval studied (20 days), MG motoneuron electrical properties [input resistance, afterhyperpolarization (AHP) duration, conduction velocity, time constant, rheobase current, and sag] exhibited significant changes that were nearly identical to those described for spinal motoneurons following section of ventral roots or motor nerves or in the earliest stages of reinnervation. 5. At the 44-60 day postoperative (DPO) intervals, several motoneuron electrical properties showed signs of recovery to control levels. At 44 DPO, average values of input resistance, time constant, and AHP duration declined from the significant increases observed at 20 DPO and could not be distinguished statistically from control mean values. 6. These indications of an early recovery of normal electrical properties were not sustained. At subsequent postoperative intervals (90, 120, and 150-180 DPO), average values of motoneuron electrical properties tended to be similar to those observed at 20 DPO. 7. Correlations observed among control motoneuron electrical properties were weakened and the pattern of correlation was disrupted at all postoperative intervals. 8. In conjunction with previous results demonstrating recovery of normal electrical properties following reinnervation (Foehring et al. 1986b), our findings suggest that functional contact with muscle is required for the full expression of the normal range of motoneuron electrical properties.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

The electric organ discharges of the gymnotiform fishes: II. Eigenmannia.

We present detailed measurements of the electric organ discharge of the weakly electric fish, Eigenmannia sp. These maps illuminate, with high resolution in both space and time, the electric organ discharge potential and electric field patterns in the water about the fish and on the skin surface itself. The results demonstrate that the electric organ discharge of Eigenmannia approximates a simple oscillating dipole, which confirms previous descriptions and assumptions, but is in contrast to the electric organ discharges of several other gymnotiform species. Over each cycle of Eigenmannia's electric organ discharge, the electric field amplitude measured at any point near the fish oscillates from positive to negative, but the field vector remains nearly constant in direction. This electric organ discharge pattern is correlated with known anatomical and physiological features of the fish's electric organ, and confirms that the activation of electrocytes comprising the organ is well synchronized. As a result, the relatively simple electric organ discharge leads to a fairly uniform pattern of electrosensory stimuli along the body surface, which may facilitate central processing of electrosensory images. Electric organ discharge maps and animations resulting from this series of studies are available via the Internet (http:@www.bbb.caltech.edu/ElectricFish, or www.fiu.edu/ approximately stoddard/electricfish.html).

Animals↗

Release of noradrenaline and ATP by electrical stimulation and nicotine in guinea-pig vas deferens.

Effects of electrical stimulation and nicotine on ATP and tritium outflow and smooth muscle tension were studied in the guinea-pig isolated vas deferens preincubated with [3H]-noradrenaline. ATP was measured using the luciferase technique. Electrical stimulation caused biphasic contractions and an acceleration of ATP and tritium outflow. The contraction amplitude and the overflow of ATP increased markedly, whereas the overflow of tritium increased only slightly with the frequency of stimulation (1-10 Hz; constant number of 60 pulses). The contraction amplitude did not increase with an increase in pulse number (20-540 pulses; constant frequency of 5 Hz), whereas the overflow of ATP increased slightly, and that of tritium markedly. Nicotine caused monophasic, transient contractions and, again, an acceleration of ATP and tritium outflow. Contractions, ATP and tritium overflow increased with the concentration of nicotine (56-320 mumol/l) in an approximately parallel manner. The influence of some drugs on responses to electrical stimulation (60 pulses, 5 Hz) and nicotine (180 mumol/l) was investigated. Tetrodotoxin blocked all effects of electrical stimulation but did not change those of nicotine. The reverse was true for hexamethonium. Neither electrical stimulation nor nicotine caused contraction or an increase in ATP outflow after pretreatment with 6-hydroxydopamine. The main effects of prazosin 0.3 mumol/l were to reduce electrically evoked contractions (above all second phase) as well as nicotine-evoked contractions and the nicotine-evoked overflow of ATP (the latter by about 81%). Prazosin also tended to diminish the electrically evoked overflow of ATP. alpha,beta-Methylene-ATP 10 mumol/l elicited a transient contraction and ATP overflow on its own. The main change in the subsequent state of desensitization was a decrease of the first phase of electrically evoked contractions. The main effects of prazosin combined with desensitization by alpha,beta-methylene-ATP were marked decreases of electrically evoked contractions (by 94%), the electrically evoked overflow ATP (by 66%), nicotine-evoked contractions (by 97%) and the nicotine-evoked overflow of ATP (by 70%). It is concluded that both electrical stimulation and nicotine release noradrenaline and ATP in guinea-pig vas deferens. Only part of the evoked overflow of ATP (about 32%) is neural in origin. Another part probably originates from smooth muscle cells where it is released by neurogenic noradrenaline acting at alpha 1-adrenoceptors. Corelease leads to cotransmission: electrically as well as nicotine-evoked contractions consist of adrenergic and purinergic components. Varying types of stimulation release cotransmitter mixtures of varying composition.(ABSTRACT TRUNCATED AT 400 WORDS)

Adenosine Triphosphate↗

Electrical stimulation-induced contraction to reduce blood stasis during arthroplasty.

Deep venous thrombosis and subsequent pulmonary embolism due to venous pooling/stasis commonly occur in patients during hip and/or knee arthroplasty (i.e., replacement). This problem may be alleviated by using techniques to promote lower limb blood flow. Electrical stimulation-induced contractions have been shown to activate the skeletal muscle pump, promote limb blood flow, and may be effective for reducing venous pooling/stasis and edema. Therefore, electrical stimulation may reduce the incidence of deep venous thrombosis (DVT) and pulmonary embolism (PE) during and following surgery. The overall goal of this project was to evaluate the clinical efficacy of sequential electrical stimulation-induced leg muscle contractions on the venous blood flow during surgery. The degree of venous pooling/stasis was monitored via electrical impedance changes in the thorax. The changes in the patient's central hemodynamics were then calculated. Thirty patients were recruited and randomly assigned to either a control group (n = 15, mean age = 66.4 +/- 7.3) or experimental group (n = 15, age = 60.7 +/- 9.7). Both groups received the standard medical treatment for prevention of DVT (i.e., coumadin, heparin, etc.) and compression stockings (TED, Kendall). The control group used the sequential compression device (SCD + TED) and the experimental group used electrical stimulation (ES + TED). Electrical stimulation was applied via surface electrodes to the lower-limb muscles (tibialis anterior and gastrocnemius) and upper limb muscles (quadriceps femoris and hamstrings). These muscles contracted sequentially, using an eight-channel electrical stimulator. Four seconds of calf (contraction/compression) were followed by 7-s of calf and thigh (contraction/compression) interspersed by 60-s rest period during both electrical stimulation or sequential compression device. This cycle continued throughout the surgery (60-75 min) for both groups. At 15 min intervals, venous return was monitored by impedance cardiograph. Physiologic responses including ventricular stroke volume (SV), cardiac output (CO), heart rate (HR), total peripheral resistance (TPR), as well as mean arterial pressure (MAP) were monitored. These responses were statistically analyzed and compared throughout the surgery within each group and between the two groups. The results show stroke volume and cardiac output to be higher throughout surgery in the electrical stimulation group as compared with the sequential compression device group. The heart rate was consistently lower during electrical stimulation for both groups. Total peripheral resistance did not change in the electrical stimulation group; but increased in the sequential compression device group. The data suggest that continuous electrical stimulation-induced contractions could improve lower leg circulation by eliciting the physiologic muscle pump. This will lead to improved venous circulation and reduction of blood stasis during total hip and/or knee surgery. This technique may offer greater protection against DVT and PE during surgery than the commonly used sequential compression device.

Bandages↗

Latency of effects evoked by electrical and magnetic brain stimulation in lower limb motoneurones in man.

1. The latency of effects in the tibialis anterior (TA) and soleus (Sol) muscles evoked by electrical and magnetic stimulation of the motor cortex was evaluated in human subjects by H reflex testing. Post-stimulus time histograms (PSTHs) were established for the discharge of single voluntarily activated motor units and motor-evoked potentials (MEPs) in the surface electromyogram. 2. At rest both electrical and magnetic stimulation evoked an inhibition of the Sol H reflex at the lowest intensities of stimulation. In some subjects a facilitation with an earlier onset was seen when increasing the stimulation strength. When the anode for the electrical stimulation was placed at the vertex directly above the leg motor area, the inhibition or facilitation often had the same latency as when evoked by magnetic stimulation. However, when the anode was placed 2-3 cm lateral to the vertex, effects evoked by the electrical stimulus often occurred 1-2 ms earlier. 3. Short-latency peaks in the PSTH of the discharges of single TA motor units also tended to occur earlier when evoked by electrical stimulation with the anode lateral to the vertex than when evoked by magnetic stimulation or electrical stimulation with the anode at the vertex. 4. In one subject, near-maximal electrical stimulation evoked MEPs with a latency corresponding to that seen following stimulation of the brainstem by electrodes placed bilaterally over the mastoid processes approximately 16 cm more distal. Maximal magnetic stimulation, in contrast, never resulted in responses with a latency shorter than that seen with the weakest electrical stimuli at the vertex. 5. The initial facilitation of the Sol H reflex evoked by magnetic stimulation and by electrical anodal stimulation at the vertex increased when the subject performed a voluntary plantarflexion. In contrast, the earlier facilitation evoked by electrical anodal stimulation 2-3 cm lateral to the vertex had the same size both at rest and during contraction. 6. We suggest that magnetic stimulation and electrical anodal stimulation at the vertex may preferentially activate descending cortical cells at, or close to, the cell soma. The initial responses evoked by these two stimuli may therefore be influenced by the excitability of the cortical cells. On the other hand, electrical stimulation with the anode 2-3 cm lateral to the vertex seems to often activate the axons at a deeper level. The initial responses evoked by this type of stimulation may therefore not be influenced by the excitability of the cortical cells.

Adult↗

Acoustically derived auditory nerve action potential evoked by electrical stimulation: an estimation of the waveform of single unit contribution.

An experimental study of the electrical stimulation of the guinea pig cochlea is made using an electrode on the round window for both stimulation and recording. The neural response is separated from the electrical artifact with a masking procedure combined with a low amplification, "statistical" averaging method [Charlet de Sauvage et al., Hear. Res. 2, 343-346 (1980)]. The high electrical impedance required for recording physiological responses implies the use of a current pulse generator. Monitoring of evoked potentials from the auditory cortex provides evidence that the effects of electrical stimulation (and of masking noise) are of auditory origin. The electrically evoked round window response is of very short latency (less than 0.2 ms). There is a response threshold for both electrical stimulus and masking noise. The response amplitude varies monotonically as a function of masking noise or electrical stimulus intensity. Experiments with high-pass noise masking suggest that the electrical stimulus is mainly acting on basal fibers. The response latency and waveform are independent of electrical stimulus intensity, repetition rate, masker level, or spectrum. Little intersubject variation is noted. Our experiments (reciprocal forward masking by electrical and acoustic stimuli) suggest that a direct, instantaneous electrical stimulation of the fibers occurs. We believe that this response to electrical stimulation represents the mean unit response of the auditory nerve fibers. This approach may be useful in the separate study of cochlear and VIIIth nerve functions and in the analysis (deconvolution) of the acoustically evoked compound AP.

Acoustic Stimulation↗

A quantitative analysis of passive electrolocation behavior in electric fish.

Weakly electric fish of the families Gymnotidae and Hypopomidae (Gymnotiformes) are able to locate the electric discharges from conspecifics or from dipole electrodes, and they demonstrate this by making rapid, well-directed approaches toward these electrical sources. A video tracking system was used to follow the movements of electric fish in a large tank and an analytic method was used for computing the direction and magnitude of the electric field anywhere within the cylindrical test tank. Using a static analysis method, we describe the posture of test fish relative to the electric fields during their approaches to stationary or moving electrical stimuli. Using a dynamic analysis, we examine the movements of the fish including the sign and magnitude of velocity and bending in response to electric fields. Electric fish seek to maintain a zero error angle between their body orientation and the local electric field. They do so by bending their body in the direction of the local electric field. The response has a delay of approximately 0.5 s. Swimming in reverse inverts the direction of the bend. These fish also use 'V-turns' to redirect their swim directions when encountering rapidly-changing electric fields.

Animals↗

Comparison of coupling of humans to electric and magnetic fields with frequencies between 100 Hz and 100 kHz.

Recent laboratory and epidemiological results have stimulated interest in the hypothesis that human beings may exhibit biological responses to magnetic and/or electric field transients with frequencies in the range between 100 Hz and 100 kHz. Much can be learned about the response of a system to a transient stimulation by understanding its response to sinusoidal disturbances over the entire frequency range of interest. Thus, the main effort of this paper was to compare the strengths of the electric fields induced in homogeneous ellipsoidal models by uniform 100 Hz through 100 kHz electric and magnetic fields. Over this frequency range, external electric fields of about 25-2000 V/m (depending primarily on the orientation of the body relative to the field) are required to induce electric fields inside models of adults and children that are similar in strength to those induced by an external 1 microT magnetic field. Additional analysis indicates that electric fields induced by uniform external electric and magnetic fields and by the nonuniform electric and magnetic fields produced by idealized point sources will not differ by more than a factor of two until the sources are brought close to the body. Published data on electric and magnetic field transients in residential environments indicate that, for most field orientations, the magnetic component will induce stronger electric fields inside adults and children than the electric component. This conclusion is also true for the currents induced in humans by typical levels of 60 Hz electric and magnetic fields in U.S. residences.

Adult↗

Design features for electric communication.

How do the communication discharges produced by electric fish evolve to accommodate the unique design features for the modality? Two design features are considered: first, the limited range of signaling imposed on the electric modality by the physics of signal transmission from dipole sources; and second, the absence of signal echoes and reverberations for electric discharges, which are non-propagating electrostatic fields. Electrostatic theory predicts that electric discharges from fish will have a short range because of the inverse cube law of geometric spreading around an electrostatic dipole. From this, one predicts that the costs of signaling will be high when fish attempt to signal over a large distance. Electric fish may economize in signal production whenever possible. For example, some gymnotiform fish appear to be impedance-matched to the resistivity of the water; others modulate the amplitude of their discharge seasonally and diurnally. The fact that electric signals do not propagate, but exist as electrostatic fields, means that, unlike sound signals, electric organ discharges produce no echoes or reverberations. Because temporal information is preserved during signal transmission, receivers may pay close attention to the temporal details of electric signals. As a consequence, electric organs have evolved with mechanisms for controlling the fine structure of electric discharge waveforms.

Animal Communication↗

Electrical potential changes, H+ translocation and phosphorylation induced by short flash excitation in Rhodopseudomonas sphaeroides chromatophores.

1. The basal decay of the carotenoid shift of chromatophores from photosynthetic bacteria following short flash excitation is approximately biphasic. The decay indicates the dissipation of the transmembrane electrical potential. 2. The H+ efflux following rapid H+ binding after a flash, measured from the colour change of added cresol red, shows very similar kinetics to the carotenoid shift decay suggesting that the dissipation of the electric potential decay is a consequence of the H+ efflux. 3. The electric potential decay is stimulated when the chromatophore suspension is supplemented with ADP and Pi (in either the presence or absence of antimycin A). 4. The stimulated electric potential decay by ADP and Pi has a similar pH dependence to that of phosphorylation in continuous light. 5. The stimulation of the electric potential decay by ADP and Pi is reversed, by aurovertin, an antibiotic which inhibits phosphorylation. 6. The stimulation of the electric potential decay by ADP+Pi is also reversed by the inhibitors oligomycin and venturicidin. These inhibitors, but not aurovertin, also inhibit the fast phase of the decay under non-phosphorylating conditions. 7. Valinomycin accelerates the overall rate of decay of the electric potential, inhibits the ADP and Pi stimulated electric potential decay, and inhibits the flash-induced phosphorylation. The decay rate of the H+ efflux however, is slower in the presence of this ionophore. 8. Nigericin-type ionophores accelerate the overall decay rate of the H+ efflux and inhibit the ADP and Pi stimulated electric potential decay. The basal rate of the electric potential decay is unaffected by treatment with these ionophores. 9. When a coupling factor associated with the chromatophore ATPase is removed from the membrane, both the stimulation of the electric potential decay by ADP and Pi and ADP phosphorylation are inhibtied. Both reactions are completely restored after reconstitution with the crude coupling factor extract. The basal electric potential decay rate is not affected by the removal of coupling factor.

Adenosine Diphosphate↗

Biliary, pancreatic, and sphincter of Oddi electrical and mechanical signals recorded during ERCP.

Measurements of biliary tract motility have focused on radiologic and pressure measurements to quantify biliary motility rather than measurements of electrical activity of the biliary tract. We previously reported the recording of biliary electrical signals during ERCP and now report on the continued development and validation of a system to measure biliary tract electrical activity as well as biliary mechanical activity. In 26 patients presenting with a variety of clinical indications, we recorded measurements of electrical activity from the common bile duct sphincter (16 patients), pancreatic duct sphincter (eight patients), and/or sphincter of Oddi (eight patients). Electrical recordings were performed with a specially modified ERCP catheter, using two circular electrodes as well as a custom catheter that measured both electrical and mechanical activity. Electrical activity of the biliary tract was successfully recorded in 25 of 26 patients (96%), including the common bile duct sphincter (16 patients, 62%), pancreatic duct sphincter (eight patients, 31%) and sphincter of Oddi (eight patients, 31%). Along with the electrical recordings, common bile duct sphincter mechanical activity was recorded in 12 patients (67%), pancreatic duct sphincter mechanical activity in six patients (33%), and sphincter of Oddi mechanical activity in six patients (33%). Frequency analysis of electrical signals revealed a mean frequency (cycles/min) of 4.7 +/- 0.5 in the common bile duct sphincter, 4.1 +/- 0.6 in the pancreatic duct sphincter, and 4.9 +/- 0.7 in the sphincter of Oddi. Phasic mechanical frequency in cycles per minute was recorded at a frequency of 4.8 +/- 0.5 in common bile duct sphincter, 4.0 +/- 0.6 in pancreatic duct sphincter, and 5.3 +/- 0.9 in sphincter of Oddi. Tonic pressure (averaged 12.1 +/- 1.5 mm Hg) in common bile duct sphincter, 12.4 +/- 1.4 mm Hg in pancreatic duct sphincter, and 15.0 +/- 5.1 mm Hg in sphincter of Oddi. Analysis of wave form propagations (noted as percentage antegrade, retrograde, or indeterminant) revealed 50% antegrade, 23% retrograde, and 27% indeterminant). One patient was recorded on two occasions via ERCP; the same patient had an intraoperative recording. All three recordings showed similarities. We conclude that measurements of biliary, pancreatic, and sphincter of Oddi electrical and mechanical activity are feasible and can be done as part of ERCP. There was good correlation between biliary tract electrical and mechanical events and different wave form characteristics were noted for different parts of the biliary tree. Further studies are warranted to evaluate the potential usefulness of measurement of biliary tract electrical activity, and to confirm its correlation with mechanical events in the pancreato-biliary tree.

Adult↗