Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Dry Socket”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

GBR in human extraction sockets and ridge defects prior to implant placement: clinical results and histologic evidence of osteoblastic and osteoclastic activities in DFDBA.

This study evaluated new bone formation in 3 types of osseous defects following treatment with demineralized freeze-dried bone allografts (DFDBA) and cell-occlusive membranes. For 8 patients electing to receive implant treatment, a distinction was made among 3 clinical situations: (1) existing alveolar ridge defects; (2) extraction sockets with lost buccal plate; and (3) extraction sockets with an intact alveolus. Implants were placed a mean of 6 months after the regenerative procedure. Clinical examination of bone width and height at the time of implant placement showed sufficient augmentation or preservation, and implants were inserted without incident. Histologic examination of hard tissue biopsies obtained from the implant sites revealed no discernible differences among the 3 types of defects. Specifically, all sites demonstrated DFDBA particles surrounded by woven or lamellar bone. No fibrous encapsulation of DFDBA or inflammatory reaction was observed. Osteoblasts were found lining marrow spaces. Howeship's lacunae, with and without resident osteoclasts, were clearly seen in several DFDBA particles; this finding supports the belief that DFDBA undergoes osteoclasis in vivo. These results demonstrate that commercially available DFDBA has osteoconductive properties that lead to appositional new bone growth in both self-contained and non-self contained osseous defects.

Adult↗

A study on the development and the deodorizing capability of metal-phthalocyanine processed stump socks for amputees.

The socks which were treated with Metal-Phthalocyanine, a derivative of an artificial enzyme, were developed by the author and called Kobe Stump Socks(KSS). KSS was made of a cotton cloth that had undergone an ammonium salt cationization process and also a Metal-Phthalocyanine process. The study from a bacteriological view and the moisture absorption effect of KSS revealed that the mechanism of the deodorizing ability was bared on the decomposition function of Metal-Phthalocyanine, while the antibacterial function came from the cationization and also that the high water absorption speed and capacity further enhanced these two functions. In this report, the author studied the deodorizing capability of KSS. To measure the adherence of an odor substance, ammonia, a testing device that measured this adherence was used. As a result, the adherence of ammonia to KSS was more than three times that of an unprocessed cloth. KSS had been used as stump socks on the stumps of amputees who were using prosthetic limbs, and a snuff test on the difference of the odor strength inside the socket was done. Of 33 subjects, 32 recognized a deodorizing effect. From these facts, KSS was proven to dry and deodorize the limb surface with the moisture absorption effect and deodorizing capabilities due to the Metal-Phthalocyanine process. These characteristics were never recognized in other stump socks. These date mentioned above suggested that KSS was the best material to deodorize prosthetic limb sockets.

Amputation Stumps↗

Variations in bone regeneration adjacent to implants augmented with barrier membranes alone or with demineralized freeze-dried bone or autologous grafts: a study in dogs.

A study was performed in two large hound dogs to evaluate the bone-induction potential of demineralized freeze-dried bone (DFDBA) placed into defects adjacent to implants that were placed into extraction sockets. Two implants were untreated controls, two implants received only Gore-Tex Augmentation Membrane (GTAM), two implants received GTAM and autologous bone, and six sites received GTAM and DFDBA. DFDBA was prepared from the long bones of a dog of the same breed as the experimental dogs. P2, P3, and P4 were extracted bilaterally, and buccal defects were created and measured. Twelve commercially pure titanium Brånemark implants were placed. At 12 weeks, clinical measurements were taken and the dogs were sacrificed. The untreated control defects had a mean clinical bone fill of 1.75 mm (37%). Sites treated with autologous bone had a mean of 5.0 mm (95%) of clinical bone fill within the original defects. Sites treated with DFDBA and barriers had 3.8 mm (75%) of bone fill, while sites treated with membranes alone had a mean of 4.2 mm (80%) of bone fill. Histologic evaluation revealed that DFDBA sites had retained nonviable bone chips in 45.4% of the bone matrix, and only 8.3% was lamellar bone. Autologous graft sites had 26.2% retained bone chips within the bone matrix, and 61% percent of the matrix consisted of lamellar bone. For GTAM-only sites, 70.2% of the matrix was lamellar bone and 29.8% was woven bone. Retained DFDBA bone chips were nonviable, occasionally surrounded by woven bone, and appeared to break up and then remineralize without the presence of osteoclastic or osteoblastic activity. Retained autologous bone chips were surrounded and incorporated by the host bone. The autologous bone grafts and DFDBA implants were considered to be osteoconductive. For the three treatment groups, within the defects there were sparse bone-implant contacts. The results indicate that GTAM barriers alone or with autologous bone grafts produced the best clinical and histologic results. DFDBA did not appear to induce bone formation in any of the evaluated specimens.

Alveolar Process↗

Ridge preservation with freeze-dried bone allograft and a collagen membrane compared to extraction alone for implant site development: a clinical and histologic study in humans.

BACKGROUND: Tooth extraction typically leads to loss of ridge width and height. The primary aim of this 6-month randomized, controlled, blinded, clinical study was to determine whether ridge preservation would prevent post-extraction resorptive changes as assessed by clinical and histologic parameters. METHODS: Twenty-four patients, 10 males and 14 females, aged 28 to 76 (mean 51.5 +/- 13.6), requiring a non-molar extraction and delayed implant placement were randomly selected to receive either extraction alone (EXT) or ridge preservation (RP) using tetracycline hydrated freeze-dried bone allograft (FDBA) and a collagen membrane. A replaced flap, which did not completely cover the sockets, was used. Following extraction, horizontal and vertical ridge dimensions were determined using a modified digital caliper and an acrylic stent, respectively. Prior to implant placement, a 2.7 x 6.0 mm trephine core was obtained and preserved in formalin for histologic analysis. RESULTS: The width of the RP group decreased from 9.2 +/- 1.2 mm to 8.0 +/- 1.4 mm (P<0.05), while the width of the EXT group decreased from 9.1 +/- 1.0 mm to 6.4 +/- 2.2 mm (P<0.05), a difference of 1.6 mm. Both the EXT and RP groups lost ridge width, although an improved result was obtained in the RP group. Most of the resorption occurred from the buccal; maxillary sites lost more width than mandibular sites. The vertical change for the RP group was a gain of 1.3 +/- 2.0 mm versus a loss of 0.9 +/- 1.6 mm for the EXT group (P<0.05), a height difference of 2.2 mm. Histologic analysis revealed more bone in the RP group: about 65 +/- 10% versus 54 +/- 12% in the EXT group. The RP group included both vital bone (28%) and non-vital (37%) FDBA fragments. CONCLUSIONS: Ridge preservation using FDBA and a collagen membrane improved ridge height and width dimensions when compared to extraction alone. These dimensions may be more suitable for implant placement, especially in areas where loss of ridge height would compromise the esthetic result. The quantity of bone observed on histologic analysis was slightly greater in preservation sites, although these sites included both vital and non-vital bone. The most predictable maintenance of ridge width, height, and position was achieved when a ridge preservation procedure was employed.

Adult↗

Histological evaluation of freeze-dried dura mater (FDDMA) used in guided bone regeneration (GBR): a time course study in man.

In 26 patients freeze-dried dura mater (FDDMA) membranes were used in fenestrations and dehiscences around dental implants, in implants inserted into postextraction sockets, in vertical ridge augmentation and in sinus lifting procedures. A re-entry procedure was carried out after 6, 9 and 12 months. In all patients a small portion of the membrane was removed and examined. No inflammatory infiltrate was present in the tissues around the membranes. No cells were present inside the membranes and only in the most peripheral portions was it possible to observe a few cells positive to acid phosphatase. The FDDMA membranes appeared to resorb slowly, did not seem to elicit an inflammatory reaction, and at 12 months they still appeared to play a role in cell occlusion.

Adult↗

Effects of salmon calcitonin on growth of teeth and on extraction socket healing in young rats.

The influence of salmon calcitonin on the growth of teeth and alveolar bone, and on the healing of alveolar sockets has been studied in young male rats. The experimental animals received daily injections of salmon calcitonin 0.5 MRC-U/kg body weight, whereas the control group received the vehicle. The rats were sacrificed at 14 and 28 days after the tooth extractions. Salmon calcitonin had no effect on the dry weight, calcium concentration and mineralization of the maxillary molars and the alveolar bone. Neither were there any significant effects of the hormone on the healing alveolar sockets. All sockets were healed after 4 weeks. The mineralization rate of molar teeth was only a quarter of that of tibiae, which was used as a reference.

Alveolar Process↗

Technical considerations of cemented acetabular components: a 30-year evaluation.

The effect of porosity reduction cementing techniques with respect to radiolucent lines in Zone 1 and failure in acetabular components was studied in 2,237 consecutive cemented acetabular components done between 1970 and 1998. The minimum followup was 2 years. Radiolucencies in Zone 1 on initial radiographs obtained postoperatively were tabulated for five groups of patients based on cementing techniques. The percentage of loose or revised cups was calculated for six groups based on type of prosthesis used. The lowest percentage of Zone 1 radiolucencies was in a group in which bowl mixing was used. The lowest failure rate was in the group that received Charnley prostheses in which simple first generation cement techniques were used. Porosity reduction techniques did not reduce the incidence of Zone 1 radiolucencies. For the acetabular side of a total hip replacement, the biology of the bone and the techniques of cement insertion that include a dry cancellous bone bed, perforation and removal of peripheral sclerotic areas, pressurization of the entire cement mantle in the socket at one time, and complete burying of the acetabular component within the boundary of the bony acetabulum are the essential factors, not porosity reduction in the cement.

Acetabulum↗

Qualitative and quantitative comparative study on different filling materials used in bone tissue regeneration: a controlled clinical study.

This study compared, in a human model, the ability of (1) expanded polytetrafluorethylene (e-PTFE) membranes plus bone-chip autografts, (2) e-PTFE membranes plus demineralized freeze-dried bone, (3) e-PTFE membranes plus a new form of demineralized allograft bone tissue, and (4) e-PTFE membranes alone to enhance bone regeneration around dental implants placed into recent extraction sockets. The histologic results demonstrated that, in humans, guided tissue regeneration techniques are capable of producing new bone osseointegrated with titanium dental implants. Among the graft materials, autogenous bone provided the densest and the greatest amount of bone formation, but use of demineralized freeze-dried bone and a new form of de-mineralized allogenic bone matrix also improved bone regeneration compared to membranes alone after 6 months of healing.

Alveolar Bone Loss↗

Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding.

In recent years, there is an increasing utilization and demand to use magnetic fields in bioengineering applications due to its beneficial effects. Although in the last decade more attention has been given by tribologists to the electromagnetic processes taking place between sliding surfaces, which influence the tribological behaviors, but no attention has been concern with the sliding surfaces of the artificial implant joints. Therefore, the present work aims to elucidate the tribological behavior of an artificial joint implant under the effect of magnetic fields. Experimental investigation was carried out on a specially designed and constructed hip simulator on which the variations in the coefficients of friction and wear rates of the sliding surfaces were evaluated under the influence of a medium strength magnetic field suitable to apply in the human body. A realistic Ti-alloy implanted stem was used with an inserted head made from surgical grade stainless steel. This head was allowed to rub against UHMWPE sockets. The utilized type of prosthesis was "The JRI Modular Muller Standard-Total Hip Design". The performed experimental tests were conducted under both dry and lubricated sliding conditions using physiological saline solution. The designed simulator allows the coefficients of friction and the wear rates to be evaluated under realistic physiological loading and motion cycles encountered during normal walking of the human body. Comparative results are presented between the artificial joint performance in the presence and absence of the applied magnetic field. The experimental results have indicated that the presence of a medium strength magnetic field of 270 Gauss strength between rubbing surfaces resulted in high beneficial reductions in friction and wear rate of UHMWPE sliding on stainless steel either under dry or saline lubricating conditions. Therefore recommendation was forward to subject artificial implants made of stainless steel/UHMWPE combination of material to such medium strength magnetic field in animal clinical trials aiming to prolong the implant life. Scanning investigation of rubbing surfaces has revealed that the transfer of polymer to the counterface plays a dominant role in dictating the frictional and wear behaviors under dry sliding condition. Smooth molecular profile of the polymer-transferred leads to progressive reductions in friction and wear while the lumpy polymer transfer, formed at the beginning of sliding, increases both friction coefficient and wear. Two action mechanisms dominate the sliding process; adhesive and abrasive mechanisms. The presence of saline lubricant retards the formation of the beneficial polymer transfer thus leading to faster abrasion of the polymeric counterface which explains the relatively rapid and progressive increases in friction and wear.

Biocompatible Materials↗

Clinical and histologic observations of sites implanted with intraoral autologous bone grafts or allografts. 15 human case reports.

The cases reported in this paper were treated at 7 different clinical centers and present clinical and histologic observations from 15 patients and 21 human biopsies. The biopsies were taken from extraction sockets or dental implant sites which were grafted with either autologous intra-oral bone (6 sites), demineralized freeze-dried bone (DFDBA) (7 sites), or mineralized freeze-dried bone (MFDBA) (7 sites), or a combination of autologous bone, DFDBA and a barrier membrane (1 site). Six sites were grafted with DFDBA and augmented with expanded polytetrafluoroethylene (ePTFE) barrier membranes. Biopsies for histological evaluation were taken 4 to 13 months after implantation. A bone scoring system of 0 to 4 was used to evaluate the sections for dead implanted particles or the presence of vital bone. A bone score of 3 indicated the presence of dead implant material, blood vessels, islands of cartilage, osteoblasts, and new bone formation. A score of 4 indicated total replacement of the implanted material by the host bone. The average bone score for sites which received autologous bone was 2.33; for DFDBA sites, 0.98; and MFDBA was 0.18. The over-riding histologic characteristic of sites implanted with DFDBA or MFDBA was retention of non-vital graft particles within fibrous connective tissue. Biopsies taken adjacent to the host bed demonstrated incorporation of the allografts (osteoconduction). Sites grafted with autologous bone chips also demonstrated non-vital bone chips surrounded by vital host bone (osteoconduction). Sites which received barrier membranes did not appear to improve or impair bone healing of the augmented sites. Autologous bone chips harvested from within the oral cavity as well as allografts may serve as biologic fillers, but do not apparently contribute to osteoinduction. Autologous bone will eventually be resorbed and replaced by the host. DFDBA and MFDBA are resorbed very slowly and apparently do not contribute to osteoinduction. Allografts apparently are not resorbed by osteoclasts and therefore their continued use around dental implants is questioned.

Adult↗

The friction of explanted hip prostheses.

Charnley prostheses, retrieved at revision surgery, were studied to assess the effects of friction on the total hip replacement procedure. Frictional resistance was measured using the Durham hip function simulator under both dry and lubricated conditions. The friction factor values (f) for the explanted prostheses were found to have a non-Gaussian distribution with medians of 0.13 [inter-quartile range (IQR) 0.10-0.16] and 0.06 (IQR 0.005-0.08) for dry and lubricated (n = 0.01 Pa s) regimes, respectively. New Charnley prostheses had values of f equal to 0.11 +/- 0.025 and 0.04 +/- 0.01 under the same conditions, and showed no large deviation from a Gaussian distribution. There was found to be a statistically significant difference in the medians of the friction factors for new and retrieved prostheses in the lubricated regime. Ingression of cement into the worn region of the cup was found to increase the friction factor significantly under dry conditions. There was no evidence of an increase in the friction factor or torque for those joints that had a loose socket with respect to those that were fixed at revision. A decrease in the frictional torque against number of cycles undergone by the joint in vivo may indicate that a fatigue-type process may have a role in the loosening of the socket. However, this relationship was found not to be significant for friction measured under lubricated conditions and it seems unlikely that the frictional torque generated in this type of prosthesis will contribute significantly to the long-term loosening of the socket.

Adult↗

Bone grafting and guided bone regeneration for immediate dental implants in humans.

This study evaluated bone regeneration and osseointegration of hydroxyapatite (HA) coated and titanium plasma sprayed (TPS) implants placed in sockets immediately after extraction in 36 adults, mean age 55.2 years (range 26 to 81 years). Twelve TPS and 10 HA-coated implants in 20 patients were grafted with demineralized freeze-dried bone allograft (DFDBA), covered with a barrier material, and the facial flap coronally positioned to attain primary closure (experimental). The remaining 11 TPS and 10 HA-coated implants were placed similarly, except that no DFDBA was used (control). Osseous structures were measured at the initial placement and 6-month re-entry surgeries. At the 6-month re-entry, all implants placed were clinically osseointegrated. Bone resorption at the most coronal socket crest was -1.53 mm for the grafted group and -1.59 mm for the control group. Crestal bone apposition of 1.39 mm was noted at the most apical socket crest (ASC) for the grafted group, whereas crestal resorption of -0.11 mm was noted in the ungrafted control group (P < 0.02). Bone fill from the base of the deepest osseous defect was 5.68 mm for the grafted group and 3.18 mm for the control group (P < 0.04). Complete resolution of osseous defects occurred at 15 of 22 sites in the grafted group and at 9 of 21 sites in the control group. Clinical exposure of the barrier material and a subsequent inflammatory response at 27 of 43 sites, requires removal of the material prior to the 6-month re-entry and was associated with significantly more bone loss at the ASC sites (P < 0.01). There was no significant difference for any of the parameters when comparing the TPS with the HA-coated implants.

Adult↗

Changes in alveolar bone height and width following post-extraction ridge augmentation using a fixed bioabsorbable membrane and demineralized freeze-dried bone osteoinductive graft.

BACKGROUND: It has been shown that the amount of healed bone following guided bone regeneration (GBR) with demineralized freeze-dried bone allograft (DFDBA) and a bioabsorbable membrane is significantly less than the initial quantity. A study was designed to determine if the amount of GBR would be affected by using an osteoinductive DFDBA and bioabsorbable membrane and membrane stabilization. METHODS: Eleven extraction sites (10 patients) were treated with DFDBA and bioabsorbable membrane before placing endosseous implants. Standardized alveolar height and width measurements were taken after extraction, GBR, and 4 months postoperatively, at predetermined measurement points (sites midpoint and 3 mm mesial and distal from the midpoint) and classified as augmented (<1 mm increase of GBR height or width) or grafted (>1 mm increase). Five membranes were stabilized. RESULTS: Three mm from the crest, augmented points exhibited a complete loss of augmented width. There was also some loss of pre-GBR bone width (ranging from 4.7% to 20%) at augmented and grafted points. Five mm from the crest, augmented points lost 83.3% to 92.3% of augmented width and grafted points lost 12.9% to 18% of pre-GBR width. Loss of augmented height ranged from 93.5% to 100%. Augmented (except distal) and grafted measurement points lost 2.1% to 12% of pre-GBR height. Comparing tacked and non-tacked sites, the former manifested less loss of augmented bone width, the latter augmented bone height. CONCLUSIONS: Results indicate a complete loss of augmented width 3 mm from the crest and almost complete loss in height and width 5 mm from the crest. Membrane stabilization appeared beneficial.

Absorbable Implants↗

Alumina ceramic bearings for hip endoprostheses: the Austrian experiences.

The current authors review clinical and retrieval experiences with hemispheric monolithic alumina ceramic sockets (Group 1), implanted between 1976 and 1979, and similar modular titanium sockets with alumina ceramic inlays (Group 2), implanted between 1990 and 1995. Both cementless sockets articulated with alumina ceramic femoral ball heads for total hip joint replacements. Clinical followup of patients with hemispheric monolithic alumina ceramic sockets (Group 1, 138 sockets) resulted in a total failure rate of 19.6% after 5 to 20 years. Radiologic analysis of eight stable sockets showed migration of 0.2 mm to 2.89 mm, but in four sockets at risk for late aseptic failure after an average followup of 12.5 years as much as 13.4 mm of migration was seen. Histologic evaluation revealed pseudosynovial membranes as thick as 1 mm with fine birefringent wear particles within mononuclear macrophages around two stable retrieved sockets. The membranes around four loose sockets were 6 to 10 mm thick and also heavily loaded with larger alumina wear particles. After 7 years followup clinical analysis of patients with modular titanium sockets with alumina ceramic inlays (Group 2, 30 sockets) resulted in four revisions, compared with one revision of 50 identical sockets (control group) with polyethylene instead of alumina ceramic inlays. Wear particle analyses in scanning electron microscopy showed significantly more particles (x 10(9) +/- standard deviation/g dry tissue) from the control group (4.26+/-6.38), compared with alumina ceramic bearings of Group 1 (0.70+/-0.79), and of Group 2 (1.62+/-2.13). The alumina particle sizes ranged between 0.13 and 78.38 microm. The mean annual linear wear of 38.8 microm was calculated for the bearings in Group 1, and of 26.94 microm for bearings in Group 2. These results support the good tribologic and biologic performance of alumina ceramic bearings for total hip arthroplasty.

Aluminum Oxide↗

The effects of guided bone regeneration and grafting on implants placed into immediate extraction sockets. An experimental study in dogs.

Guided bone regeneration (gbr) for the treatment of insufficient bone volume around implants can be performed using membranes with or without grafting materials (i.e., autogenous, allogenous, xenogenous, or alloplastic grafts). A possible way to evaluate the quality of implant osseointegration is the torque necessary to remove implants from their bony housing. The aim of this study was to compare the torques necessary to remove dental implants from implant beds reconstructed with different bone substitutes and GBR or GBR alone in 6 adult mongrel dogs. All mandibular premolars were extracted and 3 extraction sockets on each side were enlarged using a trephine bur. A 13 mm titanium screw-type dental implant (3.75 mm diameter) was placed in each enlarged extraction socket so that only the apical 3 to 4 mm were engaged in bone. The 3 defects were then randomly treated with either 1) canine demineralized freeze-dried bone allograft (DFDBA) plus GBR using an expanded polytetrafluoroethylene membrane (DFDBA+GTAM); 2) bioabsorbable hydroxyapatite and GBR (HA+GTAM); or 3) GBR (GTAM alone). After 6 months, the torque to remove the implants was measured in 4 animals and analyzed using ANOVA. There were no statistically significant differences between the 3 groups (GTAM alone: 46.37+/-16.41 Ncm; HA+GTAM: 46.00+/-16.59 Ncm; DFDBA+ GTAM: 52.15+/-29.24 Ncm). In addition, the influence of early removal of barriers on the torque values was evaluated with the t-test. Comparing exposed versus retained membranes by treatment modality, the only statistically significant difference was found in the DFDBA+GTAM group. When the torque values of all implants with exposed and retrieved membranes were compared to all those with retained membranes a significant difference could be detected. Histologic sections were prepared from the 2 dogs not included in the removal torque testing. In the histometric analysis the GTAM alone group showed a mean mineralized bone-to-implant-contact of 27.1%, the DFDBA+GTAM group of 34.6%, and the HA+GTAM of 39.3%. The mineralized bone-to-implant-contact of the HA+GTAM group was significantly higher than that of the GTAM alone group. In addition, the mineralized bone-to-implant-contact was divided into an apical and coronal part using the apical seventh thread as the dividing landmark. In the apical region, there was no significant difference between the groups regarding mineralized bone-to-implant-contact. In the coronal part the mineralized bone-to-implant-contact of the GTAM alone group was significantly lower compared to the other 2 groups. Within the limits of this investigation, it can be concluded that the type of grafting material will not influence torque removal values, but that early membrane exposure and removal will negatively influence the torque measurements. The combination of GBR with a bone substitute increased the mineralized bone-to-implant contact.

Absorbable Implants↗

Tissue regeneration in bone defects adjacent to endosseous implants: an experimental pilot study.

Extraction socket defects or alveolar ridge defects may limit or restrict placement of implants. The present study assessed the efficacy of inducing bone formation with demineralized freeze-dried bone (DFDB), osteoinduction with hydroxyapatite (HA), and guided bone regeneration with expanded polytetrafluoroethylene (e-PTFE) in bone defects adjacent to endosseous implants in an animal model. Twenty-four implants were placed in the long bones of 3 pigs. After preparation of 24 cylindric acute defects adjacent to the coronal 5 mm of each implant, 18 of the defects were treated by DFDB, HA, or e-PTFE. The 6 remaining defects healed spontaneously with no treatment (controls). In each pig, one tibia received 4 commercially pure titanium screw implants (3.75 mm x 15 mm), while the contralateral tibia received 4 HA-coated cylindric implants (3.25 mm x 15 mm). Bone formation in response to the 3 treatments and control cases was evaluated using computer-assisted densitometric image analysis. The results showed that a higher density of tissue formed under e-PTFE membranes. A significantly greater increase in bone density was noticed in bone defects treated with an e-PTFE membrane vs DFDB (P = 0.04), in e-PTFE vs control sites (P = 0.04), and in defects treated with HA vs DFDB (P = 0.04) in HA-coated implants. In titanium implants the differences observed were not significant. It was also observed that bone regeneration in defects treated with HA differs with the type of implant used (titanium vs HA-coated implants), but such differences were not significant.

Analysis of Variance↗

Freeze-dried dura mater for guided tissue regeneration in post-extraction dental implants: a clinical and histologic study.

Soft membranes were used in 69 patients for bone regeneration around implants (blades and screws, submerged and non-submerged) placed into extraction sockets. In about 10% of the patients a prosthetic restoration was completed immediately, while in the remaining patients the prostheses were connected after a healing period of 3 to 6 months; follow-up ranged from 6 to 30 months. In 22 patients a re-entry procedure was done to evaluate the membrane and in 4 patients a bone biopsy was taken from 3 to 6 months after the placement of the membrane. In all cases the peri-implant tissues appeared clinically healthy and it was possible to see radiographically that the newly formed bone closely adapted to the implants. In most cases it was possible at 6 months re-entry to see the membrane and detach it from the underlying tissues. There was a partial dehiscence of the membrane in only 4% of the cases. After 3 months the tissue under the membrane presented macroscopical features similar to mature bone, and bone biopsies in all cases showed a spongious lamellar bone with a high level of activity and a wide band of osteoid tissue.

Adult↗

[Tooth grafts in the dog: effect at mid-term of preservation of the periodontal ligament on root and alveolar remnants].

This work was undertaken to study at middle term (5 months) the behaviour of radicular grafts implanted in newly formed sockets. In some of the grafts, the remnants of the periodontal membrane were carefully preserved in a wet medium while in the others the root surface was curetted and dried. Preservation of the periodontal tissues allowed the organization of a periodontal space. This new periodontal ligament was occasionally functional with fibres in continuity from cementum to bone. Generally it was not functional with the fibres laying parallel to cementum and bone surfaces. Early "surface resorption" of the root was prevented as well as ankylosis leading to replacement of root with bone. The extent of ankylosis was reduced. It was localized to the buccal and lingual aspects of the roots where the periodontal ligament was disorganized during the extraction procedure. In the non preserved roots, ankylosis was almost total. Roots were in part replaced with bone. At 5 months, this process was still in progress.

Alveolar Process↗