Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

On-chip proteolytic digestion and analysis using "wrong-way-round" electrospray time-of-flight mass spectrometry.

Rapid protein digestion and analysis using a hybrid microchip nanoelectrospray device and time-of-flight mass spectrometry detection are reported. The device consists of a planar glass chip with microfabricated channels coupled to a disposable nanospray emitter. Reactions between substrate and enzyme (trypsin), mixed off-chip and then immediately loaded into a sample reservoir on the device, are monitored in real time following the onset of electrospray. Protein cleavage products are determined at the optimum pH for generating tryptic fragments, directly from the digestion buffer using "wrong-way-round" electrospray, i.e., monitoring (MH)+ ions from basic solutions. Intense tryptic peptide ions are observed within a few minutes following sample loading on the microchip. Proteins were identified from low femtomole or even attomole quantities of analyte/spectrum using peptide mass fingerprinting, loading 0.1-2 pmol/microL of sample on the chip. The sequence coverage for analyzed proteins ranged from 70 to 95%. The rapid analysis of human hemoglobin is demonstrated using the technique.

Amino Acid Sequence↗

A polymeric microfluidic chip for CE/MS determination of small molecules.

A polymeric microfluidic chip made of Zeonor 1020 was fabricated using conventional embossing techniques to perform capillary electrophoresis for selected ion monitoring and selected reaction monitoring mass spectrometric detection of small molecules. A silicon master was microfabricated using photolithographic and dry etching processes. The microfluidic channel was embossed in the plastic from a silicon master. The embossed chip was thermally bonded with a Zeonor 1020 cover to form an enclosed channel. This channel (60-microm width, 20-microm depth, 2.0- and 3.5-cm length) provided capillary electrophoresis (CE) separation of polar small molecules without surface treatment of the polymer. A microsprayer coupled via a microliquid junction provided direct electrospray mass spectrometric detection of CE-separated components. An electric field of 0.5-2 kV/cm applied between the microsprayer and a separation buffer reservoir produced a separation of carnitine, acylcarnitine, and butylcarnitine with separation efficiencies ranging from 1,650 to 18,000 plates. Injection quantities of 0.2 nmol of these compounds produced a separation of the targeted polar small molecules without surface treatment of the polymer-abundant ion current signals and baseline separation of these compounds in less than 10 s. These results suggest the feasibility of polymeric chip-based devices for ion spray CE/MS applications.

Acetylcarnitine↗

Dielectrophoretic cell separation and gene expression profiling on microelectronic chip arrays.

Cell membrane dielectric properties of five different cultivated cell lines and human peripheral blood mononuclear cells (PBMC) were determined from dielectrophoretic crossover frequency measurements on a 5 x 5 microelectronic chip array. Based on distinct dielectric property differences between individual cell types, efficient cell separations were achieved by dielectrophoresis on this 5 x 5 array, which included separation of monocytic cells (U937) or human T cell leukemia virus type 1 (HTLV-1) tax-transformed cells (Ind-2) from PBMC, as well as separation of neuroblastoma cells (SH-SY5Y) from glioma cells (HTB). The purity of dielectrophoretically separated cells can be greater than 95%. Expression profiles of IL-1, TNF-alpha, and TGF-beta genes for U937 cells mixed with PBMC before and after the separation were determined by a means of electric field-facilitated hybridization on a 10 x 10 microelectronic chip array. By using the expression levels of pure U937 cells as a control, it was shown that the gene expression profiles of the postseparation cells were significantly different from those of the preseparation cell mixtures. The increase in gene expression levels for U937 cells upon lipopolysaccharide induction could be accurately determined only in the postseparation cells, while the preseparation samples masked these changes. Furthermore, by cultivating the separated HTB and SH-SY5Y cells and measuring expression of the stress-related gene c-fos, dielectrophoretic forces were shown to have little effect on cell survival and stress. The presented approach of using microelectronic chip arrays for both cell separation and gene expression profiling provides a great potential for accurate genetic analysis of specific cell subpopulations in heterogeneous samples.

Cell Line↗

A MutS-based protein chip for detection of DNA mutations.

This paper describes a new protein chip method for detection of single-base mismatches and unpaired bases of DNA, using a genetic fusion molecular system Trx-His6-Linker peptide-Strep-tagII-Linker peptide-MutS (THLSLM). The THLSLM coding sequence was constructed by attaching Strep-tag II and mutS gene to pET32a (+) sequentially with insertion of a linker peptide coding sequence before and behind Strep-tagII gene, respectively. THLSLM was expressed in E. coli AD494 (DE3) and purified using Ni(2+)-chelation affinity resin. THLSLM retained both mismatch recognition activity and streptavidin binding affinity. THLSLM was then immobilized on the chip matrix coated with streptavidin through the Strep-tag II-streptavidin binding reaction. The resulting protein chip was used to detect the mismatched and unpaired mutations in the synthesized oligonucleotides, as well as a single-base mutation in rpoB gene from Mycobacterium tuberculosis, with high specificity. The method could potentially serve as a platform to develop the high-throughput technology for screening and analysis of genetic mutations.

Adenosine Triphosphatases↗

A chip system for size separation of macromolecules and particles by hydrodynamic chromatography.

For the first time, a miniaturized hydrodynamic chromatography chip system has been developed and tested on separation of fluorescent nanospheres and macromolecules. The device can be applied to size characterization of synthetic polymers, biopolymers, and particles, as an attractive alternative to the classical separation methods such as size exclusion chromatography or field-flow fractionation. The main advantages are fast analysis, high separation efficiency, negligible solvent consumption, and easy temperature control. The prototype chip contains a rectangular flat separation channel with dimensions of 1 microm deep and 1000 microm wide, integrated with a 300-pL injector on a silicon substrate. The silicon microtechnology provides precisely defined geometry, high rigidity, and compatibility with organic solvents or high temperature. All flows are pressure driven, and a specific injection system is employed to avoid excessive sample loading times, demonstrating an alternative way of lab-on-a-chip design. Separations obtained in 3 min show the high performance of the device and are also the first demonstration of flat channel hydrodynamic chromatography in practice.

Chromatography, Liquid↗

Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry.

Quantitative bioanalysis by direct nanoelectrospray infusion coupled to tandem mass spectrometry has been achieved using an automated liquid sampler integrated with an array of microfabricated electrospray nozzles allowing rapid, serial sample introduction (1 min/ sample). Standard curves prepared in human plasma for verapamil (r2 = 0.999) and its metabolite norverapamil (r2 = 0.998) were linear over a range of 2.5-500 ng/ mL. Based on the observed precision and accuracy, a lower limit of quantitation of 5 ng/mL was assigned for both analytes. Sample preparation consisted of protein precipitation with an organic solvent containing the structural analogue gallopamil as an internal standard. Protein precipitation was selected both to maximize throughput and to test the robustness of direct nanoelectrospray infusion. Aliquots of supernatant (10 pL) were transferred to the back plane of the chip using disposable, conductive pipet tips for direct infusion at a flow rate of 300 nL/min. Electrospray ionization occurred from the etched nozzles (30-microm o.d.) on the front of the chip, initiated by a voltage applied to the liquid through the pipet tip. The chip was positioned near the API sampling orifice of a triple quadrupole mass spectrometer, which was operated in selected reaction monitoring mode. Results are presented that document the complete elimination of system carry-over, attributed to lack of a redundant fluid path. This technology offers potential advantages for MS-based screening applications in drug discovery by reducing the time for methods development and sample analysis.

Drug Monitoring↗

DNA hybridization and discrimination of single-nucleotide mismatches using chip-based microbead arrays.

The development of a chip-based sensor array composed of individually addressable agarose microbeads has been demonstrated for the rapid detection of DNA oligonucleotides. Here, a "plug and play" approach allows for the simple incorporation of various biotinylated DNA capture probes into the bead-microreactors, which are derivatized in each case with avidin docking sites. The DNA capture probe containing microbeads are selectively arranged in micromachined cavities localized on silicon wafers. The microcavities possess trans-wafer openings, which allow for both fluid flow through the microreactors/analysis chambers and optical access to the chemically sensitive microbeads. Collectively, these features allow the identification and quantitation of target DNA analytes to occur in near real time using fluorescence changes that accompany binding of the target sample. The unique three-dimensional microenvironment within the agarose bead and the microfluidics capabilities of the chip structure afford a fully integrated package that fosters rapid analyses of solutions containing complex mixtures of DNA oligomers. These analyses can be completed at room temperature through the use of appropriate hybridization buffers. For applications requiring analysis of < or = 10(2) different DNA sequences, the hybridization times and point mutation selectivity factors exhibited by this bead array method exceed in many respects the operational characteristics of the commonly utilized planar DNA chip technologies. The power and utility of this microbead array DNA detection methodology is demonstrated here for the analysis of fluids containing a variety of similar 18-base oligonucleotides. Hybridization times on the order of minutes with point mutation selectivity factors greater than 10000 and limit of detection values of approximately 10(-13) M are obtained readily with this microbead array system.

Base Pair Mismatch↗

A robust technique for assembly of nucleic acid hybridization chips based on electrochemically templated chitosan.

A nucleic acid hybridization assay was assembled onto a robust and readily addressable silicon-based chip using polysaccharide chitosan as a scaffold for the covalent coupling of probe DNA to the chip's surface. Chitosan is a unique polymer, ideally suited for this application because its net charge and solubility are pH dependent. Specifically in this work, gold-patterned electrodes were created using standard photolithographic techniques, chitosan was electrodeposited in a spatially resolved manner onto the polarized electrodes, probe DNA was covalently assembled onto the chitosan, and both DNA:DNA and DNA:mRNA hybridization detection schemes were evaluated. Hybridization of target nucleic acid was quantifiable, reproducible, and robust; the surface was regenerated and rehybridized up to eight times without loss of signal. Finally, transcriptional upregulation of the Escherichia coli chaperone, DnaK, which is an indicator of cellular stress, was observed using the hybridization chip sandwich assay. Thus, this method enables rapid and facile monitoring of gene expression in a format that is reusable and requires minimal reagent quantities.

Chitin↗

High-throughput nanoliter sample introduction microfluidic chip-based flow injection analysis system with gravity-driven flows.

In this work, a simple, robust, and automated microfluidic chip-based FIA system with gravity-driven flows and liquid-core waveguide (LCW) spectrometric detection was developed. The high-throughput sample introduction system was composed of a capillary sampling probe and an array of horizontally positioned microsample vials with a slot fabricated on the bottom of each vial. FI sample loading and injection were performed by linearly moving the array of vials filled alternately with 50-microL samples and carrier, allowing the probe inlet to enter the solutions in the vials through the slots sequentially and the sample and carrier solution to be introduced into the chip driven by gravity. The performance of the system was demonstrated using the complexation of o-phenanthroline with Fe(II) as a model reaction. A 20-mm-long Teflon AF 2400 capillary (50-microm i.d., 375-microm o.d.) was connected to the chip to function as a LCW detection flow cell with a cell volume of 40 nL and effective path length of 1.7 cm. Linear absorbance response was obtained in the range of 1.0-100 microM Fe(II) (r2=0.9967), and a good reproducibility of 0.6% RSD (n=18) was achieved. The sensitivity was comparable with that obtained using conventional FIA systems, which typically consume 10,000-fold more sample. The highest sampling throughput of 1000 h-1 was obtained by using injection times of 0.08 and 3.4 s for sample and carrier solution, respectively, with a sample consumption of only 0.6 nL for each cycle.

Journal Article↗

Microfluidic chip toward cellular ATP and ATP-conjugated metabolic analysis with bioluminescence detection.

In this article, a microfluidic platform integrating capillary electrophoresis and bioluminescence (BL) detection that was fabricated in poly(dimethylsiloxane) (PDMS) with lab-on-a-chip technology was demonstrated for cellular metabolic analyses. A microchannels network, "cross combining with Y", was designed to perform on-chip sample preparation, separation, and BL detection of ATP and ATP-conjugated metabolites, using firefly luciferin-luciferase BL system. A dynamic modification of the channel wall of PDMS proved to be crucial to reverse the direction of electroosmotic flow (EOF), which was uniquely achieved by a prewash cycle with a cationic surfactant didodecyldimethylammonium bromide. The influences of surfactant on the EOF and BL reaction were also investigated. Quantitative analyses revealed a dynamic linear range over 2 orders of magnitude for ATP, with a detection limit down to submicromolar (midattomole). The method was validated by measuring cellular ATP of E. coli. with direct on-chip cell lysis. Further work was emphasized on ATP-conjugated metabolite analysis, using galactose as an example. Assays of galactose in human urine samples confirmed the reliability of the protocol, which revealed good prospect of this platform for ATP-conjugated submetabolomic profiling.

Adenosine Triphosphate↗

Microfluidic chip for peptide analysis with an integrated HPLC column, sample enrichment column, and nanoelectrospray tip.

Current nano-LC/MS systems require the use of an enrichment column, a separation column, a nanospray tip, and the fittings needed to connect these parts together. In this paper, we present a microfabricated approach to nano-LC, which integrates these components on a single LC chip, eliminating the need for conventional LC connections. The chip was fabricated by laminating polyimide films with laser-ablated channels, ports, and frit structures. The enrichment and separation columns were packed using conventional reversed-phase chromatography particles. A face-seal rotary valve provided a means for switching between sample loading and separation configurations with minimum dead and delay volumes while allowing high-pressure operation. The LC chip and valve assembly were mounted within a custom electrospray source on an ion-trap mass spectrometer. The overall system performance was demonstrated through reversed-phase gradient separations of tryptic protein digests at flow rates between 100 and 400 nL/min. Microfluidic integration of the nano-LC components enabled separations with subfemtomole detection sensitivity, minimal carryover, and robust and stable electrospray throughout the LC solvent gradient.

Chromatography, High Pressure Liquid↗

Bonding of glass microfluidic chips at room temperatures.

A simple, room-temperature bonding process was developed for the fabrication of glass microfluidic chips. High-quality bonding with high yields (>95%) was achieved without the requirement of clean room facilities, programmed high-temperature furnaces, pressurized water sources, adhesives, or pressurizing weights. The plates to be bonded were sequentially prewashed with acetone, detergent, high-flow-rate (10-20 m/s) tap water, and absolute ethyl alcohol and were soaked in concentrated sulfuric acid for 8-12 h. The plates were again washed in high-flow-rate tap water for 5 min and, finally, with demineralized water. The plates were bonded by bringing the cleaned surfaces into close contact under a continuous flow of demineralized water and air-dried at room temperature for more than 3 h. This bonding process features simple operation, good smoothness of the plate surface, and high bonding yield. The procedures can be readily applied in any routine laboratory. The bonding strength of glass chips thus produced, measured using a shear force testing procedure, was higher than 6 kg/cm(2). The mechanism for the strong bonding strength is presumably related to the formation of a hydrolyzed layer on the plate surfaces after soaking the substrates in acid or water for extended periods. Microfluidic chips bonded by the above procedure were tested in the CE separation of fluorescein isothiocyanate-labeled amino acids.

Journal Article↗

Detection and quantification of on-chip phosphorylated peptides by surface plasmon resonance imaging techniques using a phosphate capture molecule.

We describe herein a detection and quantification system for on-chip phosphorylation of peptides by surface plasmon resonance (SPR) imaging techniques using a newly synthesized phosphate capture molecule (i.e., biotinylated zinc(II) complex). The biotinylated compound is a dinuclear zinc(II) complex that is suitable for accessing phosphate anions as a bridging ligand on the two zinc(II) ions. The compound was exposed on the peptide array and detected with streptavidin (SA) via a biotin-SA interaction by SPR imaging. In the conventional method using antibody, both anti-phosphoserine and anti-phosphotyrosine antibodies were required for phosphoserine and phosphotyrosine detection, respectively. Detection of the phosphate group by the zinc(II) complex, however, was independent of the phosphorylated amino acid residues. The calibration curve for the phosphorylation ratios was established with a calibration chip, on which phosphoserine-containing peptide probes were immobilized. The peptide probes, which were phosphorylated on the surface by protein kinase A, were detected and quantified by SPR imaging using the zinc(II) complex, SA, and anti-SA antibody. The reaction rate and the kinetics of on-chip phosphorylation were also evaluated with the peptide array. The phosphorylation ratio was saturated at approximately 20% in 2 h in this study.

Microchip Analytical Procedures↗

Chip-based on-line nanospray MS method enabling study of the kinetics of isocyanate derivatization reactions.

The reaction of propyl isocyanate (2), benzyl isocyanate (3), and toluene-2,4-diisocyanate (4) with 4-nitro-7-piperazino-2,1,3-benzoxadiazole (1) to yield the corresponding urea derivatives 5 was carried out in a continuous flow glass microfluidics chip. Real-time monitoring of the derivatization reactions was done by electrospray ionization mass spectrometry, making use of a recently reported modular chip-MS interface. Rate constants of 1.5 x 10(4), 5.2 x 10(4), and 2.4 x 10(4) M(-1) min(-1) were determined for 2, 3, and 4, respectively. Using macroscale batch conditions, the rate constants are 3-4 times lower. The faster on-chip kinetics is attributed to the more efficient molecular diffusion in the micrometer-sized channel.

Journal Article↗

Detection of 100 aM fluorophores using a high-sensitivity on-chip CE system and transient isotachophoresis.

We present a highly sensitive capillary electrophoresis (CE) assay that combines transient, single-interface on-chip isotachophoresis (ITP) and a laser-induced confocal fluorescence detection setup. We performed experimental parametric studies to show the effects of microscope objective specifications and intensity of excitation laser on optimization of a high-sensitivity on-chip CE detection system. Using the optimized detection system, single-molecule detection of Alexa Fluor 488 was demonstrated, and signal data were validated with autocorrelation analysis. We also demonstrated a separation and detection of 100 aM fluorophores (Alexa Fluor 488 and bodipy) in a fast assay using a high-sensitivity on-chip CE detection system and an ITP/CE protocol with no manual buffer exchange steps. This is, to the knowledge of the authors, the highest electrophoretic separation sensitivity ever reported.

Journal Article↗

Transport, manipulation, and reaction of biological cells on-chip using electrokinetic effects.

A microfluidic system was fabricated on a glass chip to study mobilization of biological cells on-chip. Electroosmotic and/or electrophoretic pumping were used to drive the cell transport within a network of capillary channels. Whole cells such as Saccharomyces cerevisiae, canine erythrocyte, and Escherichia coli were employed in this work. Photographs are presented to illustrate how cells are selected and transported from one location to another within the capillary network, with velocities up to about 0.5 mm/s in capillaries with a 15- x 55-microns cross section. The mixing of canine erythrocytes with the lysing agent sodium dodecyl sulfate, at an intersection within the chip, was performed to demonstrate that cell selection and subsequent reaction can be accomplished within the microchip.

Animals↗

Analysis of biosensor chips for identification of nucleic acids.

Two novel DNA-sequencing methods are described that use DNA hybridization biosensor chips. These two techniques involve either labeling the free nucleic acid with enriched stable isotopes or hybridizing DNA without labels to immobilized peptide nucleic acid (PNA) and detecting the phosphorus present in the DNA but not in the PNA. Sputter-initiated resonance ionization microprobe analysis was used to detect the presence of enriched tin isotope-labeled DNA and of phosphorus in natural DNA as a means to identify the presence of DNA after hybridization to oligodeoxynucleotides (ODNs) or PNAs, respectively, immobilized on a biosensor chip. The data clearly demonstrate that excellent discrimination between complementary and noncomplementary sequences can be obtained during hybridization of DNA to either ODNs or PNAs. The capability to detect different enriched stable isotope-labeled DNAs simultaneously allows high degrees of multiplexing which may be very advantageous for hybridization kinetics studies in complex systems, as well as significantly increasing the speed of analysis. Alternatively, by using natural DNA with PNA biosensor chips, discrimination for single-point mutation could be increased because of improved hybridization kinetics and direct analysis of genomic DNA may become possible without amplification. Both methods have the potential to provide a rapid method for DNA/RNA sequencing, diagnostics, and mapping.

Biosensing Techniques↗

Isolation of cultured cervical carcinoma cells mixed with peripheral blood cells on a bioelectronic chip.

The separation and subsequent isolation of the metastatic human cervical carcinoma cell line (HeLa cells) from normal human peripheral blood cells has been achieved by exploiting their differential dielectric properties. The isolation process is carried out on a silicon chip containing a five-by-five array of microlocations. These microlocations contain underlying circular platinum electrodes with 80-micron diameters and center-to-center spacing of 200 microns. The surfaces of the electrodes and nonmetallized areas have been coated with a permeation layer to prevent the direct contact of cells with the electrode and also to minimize the nonspecific adhesion of the cells to the chip surface. An inhomogenous ac field is applied to the electrodes to create the conditions for dielectrophoretic separation of cells. Cell separation using dielectrophoresis as well as electronic lysis on a silicon chip would provide essential sample-processing steps which may be combined with a later multiplex electronic hybridization step in an integrated assay system.

Blood Cells↗