Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Angiography”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

Diagnostic accuracy of time-resolved 2D projection MR angiography for symptomatic infrapopliteal arterial occlusive disease.

OBJECTIVE: Our objective was to evaluate the diagnostic accuracy of time-resolved 2D projection MR angiography in detecting calf and pedal artery occlusive disease. MATERIALS AND METHODS: Time-resolved MR angiography of calf and pedal arteries was performed on 59 symptomatic legs of 52 patients using the head coil and bolus injections of 6 mL of gadolinium contrast medium. Selective X-ray digital subtraction angiography was performed within 30 days after MR angiography. Calf and pedal arteries were divided into 10 segments. X-ray digital subtraction angiography and MR angiography images were retrospectively interpreted by three expert observers, who graded segments as having no significant stenosis, significant stenosis (> 50%), or occlusion. The accuracy of MR angiography interpretations was compared with the accuracy of consensus X-ray digital subtraction angiography interpretations as the standard of reference. Arterial segments with discrepant grading on X-ray digital subtraction angiography and MR angiography were reviewed again to determine the reasons for disagreement. RESULTS: Arterial phase MR angiography images free of venous contamination were obtained in every case. The agreement between MR angiography and X-ray digital subtraction angiography in depicting infrapopliteal arterial disease was fair to good (kappa = 0.44-0.92). Overall sensitivity and specificity were 83% and 87%, respectively, for detecting significant stenosis of calf and pedal arteries and 86% and 93%, respectively, for detecting occlusions. Accuracy was higher in the larger vessels-for example, calf (84%) compared with foot (71%). In 21% (22/105) of the segments graded differently on MR angiography than on X-ray digital subtraction angiography, it was believed that MR angiography was more likely to be correct than X-ray digital subtraction angiography because of visualization of late-filling arteries on MR angiography that did not opacify on X-ray digital subtraction angiography. CONCLUSION: Time-resolved 2D projection MR angiography accurately evaluates calf and pedal arteries without degradation from venous contamination.

Adult↗

Carotid artery stenosis: prospective comparison of CT, three-dimensional gadolinium-enhanced MR, and conventional angiography.

PURPOSE: To prospectively compare gadolinium-enhanced magnetic resonance (MR) angiography and computed tomographic (CT) angiography with digital subtraction angiography (DSA) for use in detecting atheromatous stenosis and plaque morphology at the carotid bifurcation. MATERIALS AND METHODS: Forty-four carotid arteries (in 22 patients) were analyzed by using CT angiography, enhanced MR angiography, and DSA. CT and enhanced MR angiograms were reconstructed with maximum intensity projection and multiplanar volume reconstruction. The following four features were analyzed: degree of stenosis on the basis of North American Symptomatic Carotid Endarterectomy Trial criteria, length of stenosis, luminal surface, and presence of ulcers. RESULTS: There was significant correlation between CT angiography, enhanced MR angiography, and DSA for degree and length of stenosis. With enhanced MR angiography and CT angiography, degree of stenosis was underestimated in two of 44 cases. No case of overestimation with CT angiography was found. Severe internal carotid artery stenoses were detected with high sensitivity and specificity: 100% and 100%, respectively, with CT angiography; 93% and 100%, respectively, with enhanced MR angiography. Luminal surface irregularities were most frequently seen at CT angiography. With CT angiography and enhanced MR angiography, more ulceration was detected than with DSA. CONCLUSION: There was a significant correlation between CT angiography, enhanced MR angiography, and DSA in evaluation of carotid artery stenosis. Enhanced MR angiography or CT angiography can be used to adequately evaluate carotid stenosis.

Aged↗

Diagnosis of carotid artery disease: preliminary experience with maximum-intensity-projection spiral CT angiography.

OBJECTIVE: Spiral CT allows continuous data to be acquired rapidly, and if a correctly timed IV bolus of contrast material is given, spiral CT angiography can be performed. This study was designed to evaluate spiral CT angiography with maximum-intensity-projection reconstructions for assessing the degree of carotid artery stenosis. SUBJECTS AND METHODS: Spiral CT angiography (of 28 carotid bifurcations in 14 patients) was compared in a blinded fashion with conventional angiography (of 28 bifurcations) and with two-dimensional time-of-flight MR angiography (of 12 bifurcations) to assess degree of stenosis. A nonblinded comparison of the contour of the lumen at the site of stenosis was then made between conventional angiography, spiral CT angiography, and MR angiography. The degree of stenosis was measured in each internal carotid artery and categorized as mild (< 30%), moderate (30-69%), or severe (70-99%) stenosis or as occlusion. Maximum-intensity-projection images were used for the evaluations; however, if calcification was circumferential and the lumen of the carotid artery could not be analyzed in the area of the calcification, the axial source images were used. RESULTS: The results of CT angiography and conventional angiography agreed overall in 25 (89%) of 28 cases (r = .921, p = .05, Spearman rank correlation). The presence of severe stenosis or occlusion was correctly identified in seven of seven cases. In the moderate and mild stenosis categories, 18 (86%) of 21 were correctly identified (r = .802, p = .122). Three internal carotid arteries (11%) had circumferential calcification that necessitated evaluation of the axial source images, and the measurements obtained from the axial images agreed well with angiographic findings. MR angiography correlated well with the various categories of stenosis. However, when we compared MR angiography directly with CT angiography and conventional angiography, we found that the degree of stenosis was overestimated when MR angiography was used. CONCLUSION: Our results show that spiral CT angiography shows normal and abnormal carotid anatomy well when compared with conventional angiography. The short examination time and clear depiction of arterial caliber in areas of stenosis are significant advantages of spiral CT angiography compared with MR angiography.

Aged↗

Three-dimensional computerized tomography angiography-guided surgery of acutely ruptured cerebral aneurysms.

OBJECT: The aim of this study was to assess whether aneurysm surgery can be performed in patients with ruptured cerebral aneurysms by using three-dimensional computerized tomography (3D-CT) angiography alone, without conventional catheter angiography. METHODS: In a previous study, 60 patients with subarachnoid hemorrhage (SAH) from ruptured aneurysms were prospectively evaluated using both 3D-CT and conventional angiography, which resulted in a 100% accuracy for 3D-CT angiography in the diagnosis of ruptured aneurysms, and a 96% accuracy in the identification of associated unruptured aneurysms. The results led the authors to consider replacing conventional angiography with 3D-CT angiography for use in diagnosing ruptured aneurysms, and to perform surgery aided by 3D-CT angiography alone without conventional angiography. Based on the results, 100 consecutive patients with SAH who had undergone surgery in the acute stage based on 3D-CT angiography findings have been studied since December 1996. One hundred ruptured aneurysms, including 41 associated unruptured lesions, were detected using 3D-CT angiography. In seven of 100 ruptured aneurysms, which included four dissecting vertebral artery aneurysms, two basilar artery (BA) tip aneurysms, and one BA-superior cerebellar artery aneurysm, 3D-CT angiography was followed by conventional angiography to acquire diagnostic confirmation or information about the vein of Labbé, which was needed to guide the surgical approach for BA tip aneurysms. All of the ruptured aneurysms were confirmed at surgery and treated successfully. Ninety-three patients who underwent operation with the aid of 3D-CT angiography only had no complications related to the lack of information gathered by conventional angiography. The 3D-CT angiography studies provided the authors with the aneurysm location as well as surgically important information on the configuration of its sac and neck, the presence of calcification in the aneurysm wall, and its relationship to the adjacent vessels and bone structures. CONCLUSIONS: The authors believe that 3D-CT angiography can replace conventional angiography in the diagnosis of ruptured aneurysms and that surgery can be performed in almost all acutely ruptured aneurysms by using only 3D-CT angiography without conventional angiography.

Adult↗

Vascular surgical society of great britain and ireland: carotid angiography is used more selectively in the asymptomatic carotid surgery trial

BACKGROUND: The ongoing Asymptomatic Carotid Surgery Trial (ACST) has randomized more than 1900 patients to determine whether carotid endarterectomy prolongs stroke-free survival compared with best medical treatment alone. Previously the Asymptomatic Carotid Atherosclerosis Study demonstrated that preoperative angiography caused stroke or death in 1 per cent of patients, and many centres have now reduced or abandoned this practice. This study determined the changing practice of carotid angiography in the ACST. METHODS: Collaborating surgeons completed questionnaires annually on their use and method of angiography. Information on patients in the ACST who had angiography at randomization was also obtained. RESULTS: In 1993, 77 per cent of responding collaborators always performed preoperative angiography and 23 per cent used angiography selectively. This trend has reversed: by 1997, 26 per cent always used preoperative angiography, 70 per cent of respondents used preoperative angiography selectively and 4 per cent had abandoned angiography (P < 0.001, chi2 for trend). Information on carotid angiography at randomization has to date been obtained on 1141 patients in the ACST. Some 44 per cent (497 of 1141) had carotid angiography at randomization. Surgical patients had angiography more commonly than those in the medical group (49 versus 42 per cent; P < 0.03, chi2 test). Changes in carotid angiography were analysed by year of randomization. In 1993, 61 per cent of patients randomized had carotid angiography compared with 42 per cent in 1996 and 1997 (P < 0.001, chi2 for trend). The use of carotid angiography was not related to degree of stenosis estimated by Doppler ultrasonography. CONCLUSION: In the ongoing ACST, there is increasingly selective use of carotid angiography. Less than half the patients in this study had carotid angiography and the use of angiography is now decreasing. This has important implications for validation of carotid duplex in this trial and in future studies.

Journal Article↗

Renal MR angiography at 1.0 T: three-dimensional (3D) phase-contrast techniques versus gadolinium-enhanced 3D fast low-angle shot breath-hold imaging.

OBJECTIVE: The purpose of this study was to evaluate the diagnostic usefulness of three different MR angiographic techniques at 1.0 T. SUBJECTS AND METHODS: In 22 patients with renal artery stenosis confirmed at intraarterial catheter angiography, we also performed unenhanced and gadolinium-enhanced three-dimensional phase-contrast MR angiography and gadolinium-enhanced single breath-hold three-dimensional fast low-angle shot MR angiography. We determined circulation time to optimize signal acquisition in gadolinium-enhanced breath-hold MR angiography after bolus injection of contrast material. RESULTS: Sensitivity, defined as the detection of a hemodynamically significant stenosis (>50% luminal narrowing), was 85% for enhanced phase-contrast MR angiography, 91% for gadolinium-enhanced MR angiography, and 95% for unenhanced phase-contrast MR angiography. The combination of unenhanced phase-contrast MR angiography and gadolinium-enhanced MR angiography yielded 100% sensitivity for hilar artery stenoses. There were 13 false-positive findings with unenhanced phase-contrast MR angiography, 10 with enhanced phase-contrast MR angiography, and four with gadolinium-enhanced MR angiography (specificity: 38%, 52%, and 79%, respectively). Accessory renal arteries were not seen on unenhanced or enhanced phase-contrast MR angiography (0/8 patients) but were detected with gadolinium-enhanced MR angiography in five of the eight patients. Interobserver agreement (kappa = .62) was best with gadolinium-enhanced MR angiography. The quality of the images was unsatisfactory for adequate evaluation of segmental renal arteries with all three MR angiographic techniques. CONCLUSION: A combination of unenhanced phase-contrast MR angiography and gadolinium-enhanced MR angiography at 1.0 T proved useful as a screening protocol for renal artery stenosis.

Adult↗

Efficacy of targeted CT angiography in evaluation of intracranial internal carotid artery disease.

RATIONALE AND OBJECTIVES: This study evaluated the efficacy of targeted computed tomographic (CT) angiography in the diagnosis of intracranial internal carotid artery (ICA) disease and compared the results of routine and targeted CT angiography. MATERIALS AND METHODS: Fifty-four patients (24 male and 30 female patients aged 2 months to 87 years) were examined with CT angiography. Digital subtraction angiography (DSA) was performed in 42. CT angiograms were reconstructed with the maximum-intensity projection (MIP) algorithm. Targeted CT angiography was performed by individually reconstructing a single ICA territory. Each ICA was divided into four segments, and findings of routine MIP CT angiography, routine MIP plus targeted CT angiography, and DSA were reviewed independently by two neuroradiologists for vascular lesions involving each segment. Routine and targeted CT angiograms were also evaluated to determine how well both ICAs were visualized. RESULTS: Routine CT angiography was rated good or excellent for ICA visualization in 64% of cases, compared with 81% for targeted CT angiography (P = .0005). The overall agreement between routine CT angiography and DSA and between routine plus targeted CT angiography and DSA was 92% and 94%, respectively. There was no statistically significant difference between the percentages of vascular lesions detected with routine CT angiography alone and with routine plus targeted CT angiography. Both methods tended to show false-positive findings of steno-occlusive disease, but targeted CT angiography showed details of aneurysms and stenotic lesions that were easily overlooked with routine CT angiography alone. CONCLUSION: Routine plus targeted CT angiography, while providing superior image quality, did not have much clinical effect; further assessment may be needed.

Adolescent↗

Carotid artery stenosis: accuracy of contrast-enhanced MR angiography for diagnosis.

PURPOSE: To assess accuracy of contrast material-enhanced magnetic resonance (MR) angiography as compared with three-dimensional (3D) time-of-flight (TOF) MR angiography and reference digital subtraction angiography (DSA) in diagnosis of carotid artery stenosis. MATERIALS AND METHODS: Enhanced and 3D TOF MR angiography and DSA were performed in 51 consecutive patients suspected of having carotid artery stenosis at duplex ultrasonography. Stenoses were measured by two independent observers blinded to clinical information and other test results. Pearson correlation coefficients were used, and kappa for interobserver variabilities was estimated. Sensitivity and specificity of enhanced and 3D TOF MR angiography were calculated and compared with those of DSA. RESULTS: Pearson correlation coefficients were 0.94 (P <.01) for enhanced angiography versus DSA, 0.92 (P <.01) for 3D TOF angiography versus DSA, and 0.93 (P <.01) for enhanced versus 3D TOF angiography for observer 1 and 0.94 (P <.01), 0.95 (P <.01), and 0.94 (P <.01), respectively, for observer 2. kappa statistics were 0.81 for enhanced angiography, 0.79 for 3D TOF angiography, and 0.78 for DSA. Stenosis measurements of observer 1 at enhanced MR angiography, with inclusion of carotid arteries on the symptomatic side only, compared with those of DSA yielded a sensitivity of 90% (95% CI: 68%, 99%) and a specificity of 77% (95% CI: 55%, 92%). 3D TOF angiography yielded a sensitivity of 86% (95% CI: 67%, 97%) and a specificity of 73% (95% CI: 50%, 89%) compared with those of DSA. For observer 2, sensitivity and specificity for enhanced angiography were 91% (95% CI: 70%, 99%) and 76% (95% CI: 52%, 91%), respectively, and 90% (95% CI: 68%, 99%) and 77% (95% CI: 51%, 92%), respectively, for 3D TOF angiography. CONCLUSION: Accuracy of enhanced MR angiography in diagnosis of severe stenosis is similar to that of 3D TOF MR angiography.

Adult↗

Vascularization of head and neck paragangliomas: comparison of three MR angiographic techniques with digital subtraction angiography.

BACKGROUND AND PURPOSE: MR angiography of the head and neck region has been studied widely, but few studies have been performed concerning the efficacy of MR angiography for the identification of the specific vascular supply of the highly vascular head and neck paragangliomas. In this study, we compared three MR angiography techniques with respect to visualization of branch arteries in the neck and identification of tumor feeders in patients with paragangliomas. METHODS: Fourteen patients with 29 paragangliomas were examined at 1.5 T using 3D phase-contrast (PC), 2D time-of-flight (2D TOF), and multi-slab 3D TOF MR angiography. In the first part of the study, two radiologists independently evaluated the visibility of first-, second-, and third-order branch arteries in the neck. In the second part of the study, the number of feeding arteries for every paraganglioma was determined and compared with digital subtraction angiography (DSA), the standard of reference in this study. RESULTS: Three-dimensional TOF angiography was superior to the other MR angiography techniques studied (P < .05) for depicting branch arteries of the external carotid artery in the neck, but only first- and second-order vessels were reliably shown. DSA showed a total of 78 feeding arteries in the group of patients with 29 paragangliomas, which was superior to what was revealed by all MR angiography techniques studied. More tumor feeders were identified with 3D TOF and 2D TOF angiography than with 3D PC MR angiography (P < .05), with a sensitivity/specificity of 61%/98%, 54%/95%, and 31%/95%, respectively. Sensitivity was lowest for carotid body tumors. CONCLUSION: Compared with intra-arterial DSA, the 3D TOF MR angiography technique was superior to 3D PC and 2D TOF MR angiography for identifying the first- and second-order vessels in the neck. With 3D TOF angiography, more tumor feeders were identified than with the other MR angiography techniques studied. The sensitivity of MR angiography, however, is not high enough to reveal important vascularization. The sensitivity of MR angiography is too low to replace DSA, especially in the presence of carotid body tumors.

Adult↗

In a managed care setting, are there sex differences in the use of coronary angiography after acute myocardial infarction?

OBJECTIVES: The goal of this study was to examine sex differences in the use of coronary angiography after acute myocardial infarction in managed care facilities by using the American College of Cardiology/American Heart Association (ACC/AHA) practice guidelines (which incorporate clinical information on infarct complications, severity of illness, and comorbidity). BACKGROUND: Although sex differences in the use of coronary angiography after acute myocardial infarction have been previously explored, the effects of indications for coronary angiography and common health insurance coverage on the sex and coronary angiography use relation have not been previously examined. METHODS: This historical prospective study analyzed data collected from a random sample of 1133 patients (377 women, 756 men) from among 2740 patients hospitalized with validated acute myocardial infarction between Jan. 1, 1990, and Dec. 31, 1992, from seven of 16 Northern California Kaiser Facilities (three with high procedure rates for coronary angiography, four with low rates relative to the average region-wide utilization rate). In accordance with the guidelines, use of coronary angiography was determined for the in-hospital and "0 to 8 weeks" postdischarge periods. Patients were assigned time specific ACC/AHA classes for coronary angiography indications (I = highly indicated, IIA = probably indicated, IIB = not harmful, III = not indicated). The independent impact of ACC/AHA class, age, race, and facility on the sex and use of coronary angiography relation was examined by the Cox proportional hazard model. RESULTS: Accounting only for ACC/AHA class, fewer women underwent coronary angiography compared with men among the "highly indicated" class I patients during the in-hospital period (43% vs 35%; p < 0.05), but not after discharge. Use of coronary angiography between the sexes was not statistically different among classes IIA, IIB, and III for both periods. After adjusting for differences in age, race, facility, and ACC/AHA class, we found no sex difference in in-hospital use of coronary angiography (hazard ratio (HR) = 1.02; 95% confidence interval [CI], 0.82 to 1.26), but among those discharged without receiving coronary angiography, women probably received fewer angiograms than did men (HR = 0.61; 95% CI, 0.37 to 1.00). For both periods, no significant sex difference in use of coronary angiography was found within ACC/AHA classes after adjustments. CONCLUSION: In a setting where health insurance is prepaid and after controlling for ACC/AHA classification for coronary angiography indications, age, race, and facility, use of coronary angiography after myocardial infarction was similar among men and women during hospitalization, but was lower among women after discharge. Likely explanations for these differences in use of coronary angiography may include effects of physician judgment, patient decision, other social factors, or clinical information not captured in the practice guidelines.

Adult↗

Current role of cerebral angiography in the diagnosis of cerebrovascular diseases.

The role of cerebral angiography in the diagnosis of cerebrovascular disease is currently being questioned because of the increasing availability of MR angiography. The purpose of this essay is to place the use of cerebral angiography in perspective in light of these new developments. In patients with atherosclerotic cerebrovascular disease, MR angiography can almost entirely supplant cerebral angiography as a screening procedure in the evaluation of the carotid bifurcation. However, detection of "pseudoocclusion" still requires cerebral angiography for accurate diagnosis. Atherosclerotic stenosis or occlusion of the major intracranial vessels at the base of the brain can be detected with MR angiography, but not as accurately as with cerebral angiography. Furthermore, for detection of more distal occlusions, cerebral angiography is still needed. A number of erroneous concepts about the risks and value of cerebral angiography have prevented its optimal use for patients with cerebrovascular disease. These myths can be countered by applying several rules to optimize the use of cerebral angiography. Subarachnoid hemorrhage is best evaluated with CT followed by detailed cerebral angiography, although MR angiography can be used as a screening test for aneurysms 3 mm or larger. Cerebral angiography is still necessary to confirm the diagnosis of cerebrovascular malformations, although MR angiography is a useful screening test. Cerebral angiography is required for the definitive diagnosis of arteritis, arterial dissection, or fibromuscular dysplasia.

Cerebral Angiography↗

Evaluation of classic 2D time-of-flight MR angiography in the depiction of severe carotid stenosis.

OBJECTIVE: The purpose of this study is to determine the sensitivity, specificity, and clinical utility of classic 2D time-of-flight MR angiography (acquired with derated gradients) as an aid to predicting severe carotid stenosis. SUBJECTS AND METHODS: Our study population was composed of 68 patients, yielding 133 carotid bifurcations for analysis. A 2D time-of-flight MR angiography pulse sequence was modified to provide greater sensitivity for carotid stenosis, which resulted in visualization of a carotid stenosis with a 70% or greater diameter as a signal void. Contrast-enhanced MR angiography was performed with the elliptical centric view order. Multiple overlapping thin-slab acquisition (MOTSA) MR angiography was performed in select patients. Digital subtraction angiography was performed in 51 patients, and the findings were used as the gold standard. In the remaining patients, findings on carotid duplex Doppler sonography and at surgery and clinical follow-up were used as the gold standard. RESULTS: In 51 patients for whom a digital subtraction angiogram was available, we found that the sensitivity of classic 2D time-of-flight MR angiography for prediction of carotid stenosis with a 70% or greater diameter was 94%, and the specificity of the technique was 97%. In three patients with severe carotid stenosis, the stenoses that appeared as signal voids on the classic 2D time-of-flight MR angiography were underestimated on contrast-enhanced MR angiography. Severe stenosis was confirmed by subsequent digital subtraction angiography, surgical results, or both. Discrepancies between findings on MOTSA MR angiography and contrast-enhanced MR angiography were resolved with classic 2D time-of-flight MR angiography. Classic 2D time-of-flight MR angiography increased diagnostic confidence of a severe stenosis in three patients with focal internal carotid artery stenosis. CONCLUSION: Classic 2D time-of-flight MR angiography has a high sensitivity and specificity for predicting carotid bifurcation stenosis of 70% or greater diameter. These probability measures allowed the detection of three significant stenoses that would have been missed on contrast-enhanced MR angiography and provided greater diagnostic confidence than contrast-enhanced or MOTSA MR angiography alone.

Aged↗

[Study of the liver and the portal venous system with digital rotational angiography].

PURPOSE: Digital subtraction angiography is of common clinical use for the evaluation of vascular disease. The rotation of the X-ray tube around the patient's body during contrast medium injection was first proposed in the early seventies in the neuroradiologic field; only recently it has been applied to the evaluation of vascular structures and abdominal parenchymatous organs. We investigated the potential clinical value of digital rotational subtraction angiography in the evaluation of the hepatic arteries and of the portal venous system. MATERIALS AND METHODS: Digital rotational subtraction angiography was performed in 46 patients (34 males and 12 females), mean age 59.3 years (range: 43-72). All the patients underwent digital rotational subtraction angiography after ultrasonographic, CT and/or MRI imaging for evaluation of hepatocellular carcinoma (31 patients) prior to trans-arterial chemoembolization, hepatic metastases from gastrointestinal cancer (9 patients) and pre-surgical study in portal hypertension (6 patients). Digital rotational subtraction angiography was performed using the following technical parameters: a maximum frame rate of 10 views per second, a 1024 x 1024 matrix, a rotation time of 5 seconds, a rotational arch of 90 degrees with a speed of 30 degrees/second. Digital rotational subtraction angiography of the liver was carried out after positioning of a Cobra angiographic catheter in the proper hepatic artery or in the left or right hepatic artery, and subsequent injection of 20-30 ml on contrast medium at a flow rate of 4-7 ml/sec. Conversely, in the portal study the catheter was placed in the splenic or superior mesenteric artery and contrast was administered at 10 ml/sec for an amount of 40-60 ml. Conventional, non-rotational angiography was always obtained with the same catheter and less contrast medium (15-25 at 4-7 ml/sec in the hepatic study, 25-40 ml at 5-7 ml/sec in the portal study). We have evaluated the diagnostic quality (rated as equal, superior or inferior) and the presence of image noise of digital rotational subtraction angiography when compared to digital non-rotational subtraction angiography. We also evaluated the tolerability and the mean time to perform the examination. RESULTS: Compared to non-rotational digital subtraction angiography, the diagnostic quality of digital rotational subtraction angiography was superior in 26 cases, equal in 20 and never inferior: these results are particularly evident in cine-mode. Diagnostic efficacy was similar in the arterial phase and generally better in the venous phase. Image noise was always perceptible, mostly in lateral and oblique views and is related to the patient's size. Noise especially hindered evaluation of the portal venous phase. Digital rotational subtraction angiography was well tolerated by all patients, although its most significative drawback was the prolonged apnea time required (about 8 seconds per single rotation) which can sometimes be difficult for elderly patients. Examination duration is about 5 to 10 minutes. Contrast medium doses required never exceeded 20-60 ml. DISCUSSION: Current evaluation of an hepatic lesion requires injections and multiple views to fully delineate arterial anatomy. This requires the radiologist to create a mental 3-D rendering based upon a 2-D view, obtained on the basis of the radiologist's experience. Rotational angiography, when reviewed in cine-loop, allows a better 3-D rendering than conventional angiography, increasing the advantages of the multiple views obtained from a single angiographic run and allowing an exact imaging of the course and direction of the hepatic arterial branching, making selective catheterization during trans-arterial chemoembolization or other interventional procedures easier. Magnification further improves the evaluation of a mass and of the arterial tree. In hepatic surgery, the most important problem is the precise knowledge of the segment involved and the position of the lesion inside the segment, since a mass in the middle of the segment requires a segmentectomy while a mass near the borders is treated by a larger resection. Digital rotational subtraction angiography improves the visibility of vascular anatomy, allows a better knowledge of hepatic artery branches and improves the angiographic investigation of the liver, permitting a correct spatial assessment. CONCLUSION: Digital rotational subtraction angiography is a useful tool for the evaluation of the liver as well as for transarterial chemoembolization or other interventional procedures. Images are obtained during a single contrast injection, with a better 3-D rendering of the hepatic artery and the portal venous system: no other method provides as complete a visualization of liver vascular anatomy after a single injection of contrast medium in one examination series. (ABSTRACT TRUNCATED)

Adult↗

[Usefulness of CO2 US angiography in treating hepatocellular carcinoma].

We evaluated the usefulness of CO2 US angiography in the detectability of and the effectiveness of TAE and/or PEIT for hepatocellular carcinoma (HCC). Twenty-three patients with HCC underwent CO2 angiography during the interventional procedure to treat HCC after examination of CT and conventional US. CO2 US angiography was observed on the US monitor by injecting CO2 microbubbles through a catheter placed in the hepatic artery. Contrast materials for CO2 US angiography were 3 ml of CO2 microbubbles prepared by vigorously mixing 3 ml of normal saline with 3 ml of 20% Intralipid, 3 ml of 20% albumin or 3 ml of the patient's own blood. In all patients, CO2 US angiography revealed equal or superior tumor detectability as compared with CT, conventional US and angiography. For demonstrating the inner structure of HCC, the image of CO2 microbubbles mixed with Intralipid was better than that of CO2 microbubbles mixed with albumin. In 9 of 23 patients, CO2 US angiography depicted nodules that had not been seen in the other images. TAE was performed in 21 patients with HCC who showed hypervascularity. In one patient in whom it was difficult to clearly depict the small lesion of HCC by conventional angiography and US, PEIT was successful under CO2 US angiography. The detectability of HCC was higher in CO2 US angiography than in CT, conventional US or angiography. The distribution of blood supply to HCC was observed easily by CO2 US angiography. In TAE of HCC, CO2 US angiography was useful to determine the dose of embolization materials without having to perform repeated angiography. It was possible to perform PEIT easily for non-detectable tumors without CO2 US angiography. CO2 US angiography was useful to evaluate the stage of HCC and to perform TAE and PEIT.

Aged↗

In vivo evaluation of patency and in-stent stenoses after implantation of nitinol stents in iliac arteries using MR angiography.

OBJECTIVE: Our study was a prospective in vivo study to evaluate whether MR angiography is suitable for assessing stent patency and grading in-stent stenoses and to examine whether the accuracy of MR angiography changes with time after stent implantation. SUBJECTS AND METHODS: In a prospective study, 34 iliac stenoses in 27 patients were treated by implantation of 35 nitinol stents. MR angiography was performed immediately after stent placement for 32 stents, and both digital subtraction angiography (DSA) and MR angiography were repeated at the 6-month follow-up for 23 stents. Three blinded observers assessed stent patency and the degree of in-stent stenoses on MR angiography and DSA (the standard of reference) images. The difference between the observers' grading of stenoses on DSA and on MR angiography was determined. Statistical analysis was performed using the Student's t test for paired samples. RESULTS: Stent patency was assessed correctly for all stents and both sets of MR angiography images. Evaluation of DSA 1 images (obtained at end of implantation procedure) revealed that 96.9% of in-stent stenoses were less than 50%. On DSA 2 images (obtained at follow-up), 95.7% of in-stent stenoses were graded as less than 50%. The difference between grading of stenoses on DSA and MR angiography images was 15.0% +/- 16.0% (minimum, 0.0%; maximum, 63.3%) for DSA 1 versus MR angiography 1 (statistically significant, p = 0.037) and 9.8% +/- 13.5% (minimum, 0.0%; maximum, 63.3%) for MR angiography 2 versus DSA 2 (not statistically significant, p = 0.355). CONCLUSION: Patency was correctly assessed for all stents on MR angiography. The quality of MR angiography regarding characterization of in-stent stenoses improved with time after stent placement. However, discrepancies of more than 60% between grading of lumen narrowing on DSA and MR angiography images occurred even at the 6-month follow-up. Thus, MR angiography is not yet a reliable technique for characterization of in-stent stenoses.

Adult↗

MR angiography in children with cerebral neurovascular diseases: findings in 31 cases.

OBJECTIVE: We evaluated the suitability of MR angiography for routine use in children with suspected intracranial vascular disease. SUBJECTS AND METHODS: Thirty-one children, 6 months to 14 years old, with intracranial lesions or clinically suspected vascular malformations were studied prospectively with conventional MR imaging and time-of-flight MR angiography. In nine cases, MR angiographic findings were verified with digital subtraction angiography or conventional angiography. All MR studies were performed on a 1.5-T MR system using a circularly polarized head coil. RESULTS: Arterial MR angiography, performed in 24 cases, revealed congenital abnormalities of the arterial vessels in 20 cases. Vessel stenosis was observed in nine patients, and displacement of intracranial arteries due to tumors could be seen in 10 patients. Seven children had no abnormal findings. Venous MR angiography was performed in seven children, with depiction of sinus thrombosis in six cases. The comparative analysis of MR angiography and digital subtraction angiography showed equivalent results in nine patients; in one patient the degree of stenosis was overestimated with MR angiography. CONCLUSION: MR angiography, when combined with MR imaging, reveals information about soft-tissue and vascular structures in a single setting. At this point, MR angiography can replace invasive conventional angiography or digital subtraction angiography only in selected cases because of software and hardware limitations. Arterial or venous MR angiography can be helpful as an additional scan in MR examinations of children with suspected cerebral neurovascular diseases, and its noninvasive nature makes it well suited for routine use in children.

Adolescent↗

Multi-section CT angiography for detection of cerebral aneurysms.

BACKGROUND AND PURPOSE: Multi-section CT has great potential for use in vascular studies. Our purpose was to determine the accuracy of multi-section CT angiography in detecting cerebral aneurysms compared with digital subtraction angiography or surgery. METHODS: One hundred consecutive patients who underwent multi-section CT angiography and either digital subtraction angiography or surgery were included in the study. Multi-section CT angiography and digital subtraction angiography results were evaluated independently by different neuroradiologists who performed aneurysm detection, quantitation, and characterization by using 2D multiplanar reconstructions, 3D maximum intensity projection, and volume-rendered techniques. RESULTS: When using intra-arterial digital subtraction angiography or surgery, 113 aneurysms (true positives and false negatives) were detected in 83 of the 100 patients. A total of 106 aneurysms (true positives) were confirmed by using digital subtraction angiography or surgery, or both. Seven aneurysms were missed when using multi-section CT angiography. Eight aneurysms were not confirmed by digital subtraction angiography and were considered to be false positive evaluations. The sensitivity for detecting aneurysms < 4 mm, 4 to 10 mm, and > 10 mm on a per-aneurysm basis was 0.84 (95% confidence interval: 0.72, 0.92), 0.97 (95% confidence interval: 0.91, 0.99), and 1.00 (95% confidence interval: 0.88, 1.00), respectively. The sensitivity, specificity, and accuracy of multi-section CT angiography for detecting aneurysms on a per-patient basis were 0.99 (95% confidence interval: 0.96, 1.00), 0.88 (95% confidence interval: 0.69, 0.94), and 0.98 (95% confidence interval: 0.95, 1.00), respectively. CONCLUSION: Multi-section CT angiography has a high sensitivity in detecting aneurysms (especially aneurysms > 3 mm). However, CT angiography is currently not sensitive enough to replace digital subtraction angiography.

Adult↗

Comparison of multistation MR angiography with integrated parallel acquisition technique versus conventional technique with a dedicated phased-array coil system in peripheral vascular disease.

PURPOSE: To assess the impact of integrated parallel acquisition technique (iPAT) on signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), venous contamination, and overall image interpretability for peripheral magnetic resonance (MR) angiography with use of a dedicated phased-array coil system. MATERIALS AND METHODS: Three-dimensional contrast material-enhanced conventional MR angiography and iPAT peripheral MR angiography was performed at three stations (pelvis, thigh, calf) in 38 consecutive patients on a 1.5-T high-performance cardiovascular system (conventional MR angiography, n=19; iPAT MR angiography, n=19). A total of 29 vessel segments per patient were analyzed. For each segment, arterial, muscle, and background signal were measured; SNR and CNR were calculated; and repeated-measures analysis of variance was performed. For each of the three stations, the degree of venous contamination and the overall confidence of interpretability were analyzed with use of ordinal logistic regression analysis accounting for correlated outcome data. RESULTS: A total of 1,018 vessel segments were available for analysis (477 with conventional MR angiography, 541 with iPAT MR angiography). Compared with conventional MR angiography, iPAT MR angiography resulted in decreased SNR and CNR in the pelvis and thigh stations but no change in the calf station. The difference in the pelvis was statistically significant (P<.007 for SNR and P<0.01 for CNR). Venous contamination in the calf station was significantly less on iPAT MR angiography (P<.003), with no significant differences in the other stations. The overall confidence of interpretability with iPAT MR angiography was significantly better on the lower station (P<.008). CONCLUSIONS: iPAT MR angiography leads to reduced SNR and CNR in the pelvis and thigh, but this does not affect interpretability of images obtained at these stations. The temporal gain results in significantly increased interpretability as a result of less venous contamination in the calf station. iPAT MR angiography is superior to conventional MR angiography for peripheral imaging.

Adolescent↗