A randomized trial of an antibiotic- and antiseptic-coated central venous catheter in the prevention of catheter-related infections.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
OBJECTIVE: To test the efficacy of the ARROWgard (Arrow International Inc, Reading, Pa) central venous catheter (CVC) coated with silver sulfadiazine and chlorhexidine (A-CVC) in the prevention of CVC-related infections. DESIGN: Prospective, randomized trial. SETTING: A tertiary care medical center. PATIENTS AND INTERVENTION: Two hundred eighty-two patients who required CVC placement were evaluated in this study. Patients were prospectively randomized to receive either a standard CVC (S-CVC) or the A-CVC. Only fresh-stick double- and triple-lumen catheters were studied. MAIN OUTCOME MEASURES: Patients were evaluated for catheter site inflammation, catheter site colonization, local catheter-related infection, and catheter-related septicemia. RESULTS: The 2 groups were matched for age, percentage in the intensive care unit, percentage receiving total parenteral nutrition, percentage with triple-lumen catheters, and duration of catheterization. Rates of catheter site inflammation in the 2 groups were similar (12% vs 10%, S-CVC group and A-CVC group, respectively). The A-CVC was associated with a significantly decreased catheter site colonization rate (49% vs 28%; 43% reduction; P<.001) and local catheter-related infection rate (22.4% vs 5.8%; 74% reduction; P<.001). Rates of catheter-related septicemia were reduced by 41% in the A-CVC group (6.4% vs 3.8%, S-CVC group and A-CVC group, respectively), but this was not statistically significant. CONCLUSIONS: Despite a marked decrease in catheter site colonization and catheter-related infection rates, the A-CVC did not significantly reduce the incidence of catheter-related septicemia. This may be due to a greater pathogenic dependence on catheter hub contamination rather than catheter site colonization or local catheter-related infection, or the relatively short (5.2 days) duration of catheterization in this study.
Explore the source record for details and available documents.
CONTEXT: Central venous catheters impregnated with chlorhexidine and silver sulfadiazine have recently been introduced for the prevention of catheter-related infections. However, there remains some uncertainty regarding the efficacy of these catheters because of conflicting reports in the literature. OBJECTIVE: To evaluate the efficacy of chlorhexidine-silver sulfadiazine-impregnated central venous catheters in the prevention of catheter-related bloodstream infection. DATA SOURCES: Studies identified from a computerized search of the MEDLINE database from January 1966 to January 1998, reference lists of identified articles, and queries of principal investigators and the catheter manufacturer. STUDY SELECTION: Randomized trials comparing chlorhexidine-silver sulfadiazine-impregnated central venous catheters with nonimpregnated catheters were included. The outcomes assessed were catheter colonization and catheter-related bloodstream infection confirmed by catheter culture. DATA EXTRACTION: Twelve studies met the inclusion criteria for catheter colonization and included a total of 2611 catheters. Eleven studies with a total of 2603 catheters met the inclusion criteria for catheter-related bloodstream infection. Most patients in these studies were from groups considered to be at high risk for catheter-related infections. Summary statistics were calculated using Mantel-Haenszel methods under a fixed-effects model. DATA SYNTHESIS: The summary odds ratio for catheter colonization was 0.44 (95% confidence interval [CI], 0.36-0.54; P<.001), indicating a significant decrease in catheter colonization associated with impregnated catheters. The studies examining the outcome of primary interest, catheter-related bloodstream infection, had a summary odds ratio of 0.56 (95% CI, 0.37-0.84; P = .005). CONCLUSIONS: Central venous catheters impregnated with a combination of chlorhexidine and silver sulfadiazine appear to be effective in reducing the incidence of both catheter colonization and catheter-related bloodstream infection in patients at high risk for catheter-related infections.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Species of Proteus, Serratia, and Pseudomonas became resistant to chlorhexidine after five to eight transfers in vitro. Cross-resistance to benzalkonium chloride also was detected. Resistance to povidone-iodine was not encountered. Chlorhexidine resistance was stable after drug-free transfers of Serratia and Pseudomonas but was transitory for Proteus.
To assess how the permeability of phenol is altered by thermal injury, it was first necessary to have baselines of comparison on normal skin. Using in vitro diffusion cells and the skin of the hairless mouse, [14C]phenol was applied to skin in an aqueous medium with a reference copermeating species, [3H]methanol, and 37 degrees permeability coefficients of the pair were evaluated as functions of animal age, skin hydration, stripping of the skin, dermis isolation, and phenol concentration. Age proved to be of little consequence to permeability over a wide age range. Prolonged aqueous soaking of the skins was also without much effect. Stripping of the skin and isolating the dermis by soaking techniques allowed assessment of individual skin strata diffusion resistances. When applied to skin in trace radiochemical concentrations, phenol behaved diffusionally as an alkanol with a chain length of six. But at concentrations greater than 2% w/v, phenol facilitated the permeation rates of itself and methanol; the effect was markedly concentration sensitive and only fractionally reversible. Concentration studies using silicone rubber membranes proved that the effects on the skin were the results of destroyed barrier integrity. At 6% phenol concentration there was an essentially instantaneous, 10-fold increase in the phenol permeability coefficient, raising it to two-thirds that observed with fully stripped skin. Overall, the data suggest that the stratum corneum is proportionally impaired as the phenol concentration is increased.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The activity of chlorhexidine, acetic, lactic and mandelic acids were examined against biofilms of Escherichia coli established on silicone discs and against the test strain growing in suspension in urine. The results showed that the concentrations of chlorhexidine and acetic acid normally used for bladder instillations to control infections in patients with indwelling catheters failed to eliminate cells from the biofilm in exposure periods of up to 2 h. Lactic acid (1% v/v) had a bactericidal effect on planktonic cells but poor activity against cells in the biofilm. Mandelic acid (1% v/v), and mandelic (1% v/v) and lactic acid (1% v/v) mixtures eliminated organisms from both suspensions and biofilms. It is suggested that these solutions be considered as alternatives to acetic acid and chlorhexidine for the washing of catheterized bladders.
The activity of chlorhexidine, mandelic acid and a mandelic/lactic mixture were tested against biofilms of four species of gram-negative nosocomial organisms that commonly infect the catheterized urinary tract. Cells growing on silicone discs were exposed to concentrations of agents used in bladder instillation. Citrobacter diversus biofilms proved to be sensitive to all three agents. Pseudomonas aeruginosa, Proteus mirabilis and Klebsiella pneumoniae all survived well in chlorhexidine but their viability was significantly reduced by the mandelic acid formulations. These results suggest that bladder instillations of mandelic acid or mandelic/lactic acids would be more effective than chlorhexidine in eliminating biofilms from catheter surfaces.
A short historical review and pharmacological data indicating the suitability of cycloserine for long-term low-dose prophylaxis of urinary tract infection are presented.
Explore the source record for details and available documents.