Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostic performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

[Serum markers of non-invasive fibrosis in chronic hepatitis C virus infection].

MATTER: Liver biopsy is recommended for the management of patients infected by hepatitis C virus (HCV) and is currently the gold standard in assessing liver histology. It's an invasive test prone to complications with a morbidity rate of 0.3 to 0.6% and a mortality rate up to 0.05%. Since the last decade, researchers developed non invasifs biomarkers of liver fibrosis as an alternative to liver biopsy. These scores are based on different algorithms with various combinations of biomarkers issued from extra-cellular matrix, serum and cells. CURRENT EVENTS: The diagnostic performance of these scores, estimated by the AUROC for significant fibrosis (>F2), in patients with chronic hepatitis C reach 0.78 to 0.90 for the most accurate. In HIV-HCV co-infected patients and patients with hepatitis C cirrhosis the diagnostic performance of these scores reach 0.74 to 0.88 and 0.73 to 0.97 respectively. PERSPECTIVES: Liver fibrosis biomarkers constitutes an alternative to liver biopsy due to their non invasive approach, their easy reproducibility and accuracy. However, these scores must be used only after a validation in multicentric independent studies. The future is based on the comparison and validation of these scores after laboratory methods standardization.

Alanine Transaminase↗

Experience-related differences in diagnosis from medical images displayed on monitors.

OBJECTIVE: To compare diagnostic accuracy using conventional versus monitor-displayed medical images in order to determine if years of experience as a board-certified clinician influences diagnostic performance in either modality. MATERIALS AND METHODS: In separate observer performance studies, six radiologists and six pathologists differing in years of experience viewed clinical images, once in the conventional modality (X-ray film or light microscopy) and once using a monitor display. Readers also were surveyed regarding their experience with digital/video display systems. RESULTS: In both studies, performance was similar for conventional and monitor modalities. For the conventional displays, there was a positive correlation between years of clinical experience and performance. For the monitor displays, however, there was a strong negative correlation between years of clinical experience and performance. Performance using the monitor displays correlated highly with experience using digital/video systems in general. CONCLUSION: More exposure to and use of monitor displays, such as recreational video games and computers, may influence positively the clinician-monitor display system interaction and improve diagnostic performance.

Data Display↗

Interpretation of renal angiography by radiologists.

OBJECTIVE: Different radiologists may show considerable variation in their interpretation of renal angiograms. We therefore wished to establish the reliability of their interpretation. DESIGN: Assessment of the intra- and inter-observer agreement of the interpretation of renal angiograms. SETTING: Tertiary referral university hospital. PATIENTS: Hypertensive patients suspected of renovascular hypertension on clinical grounds or on the basis of renography. INTERVENTIONS: Patients were prospectively selected to undergo a renal angiography via the femoral approach. MAIN OUTCOME MEASURES: Intra- and inter-observer agreement of the degree and site of stenosis. RESULTS: The difference between two estimates of the degree of stenosis ranged from 0 to 65% for the individual readers and from 0 to 75% between two readers. When the site of greatest stenosis was in the origin of the renal artery, the intra-observer agreement kappa ranged from 0.54-0.71, the inter-observer agreement across multiple readers being 0.43. In a post hoc analysis using two different cut-off points of stenosis (50 or 70%), the intra- and inter-observer agreement was better at the 70% cut-off-point. In a subset of patients with stenosis and a renin ratio greater than 1.5, both the intra- and inter-observer agreement were much better than when all angiograms were considered. CONCLUSIONS: Assessment of the diagnostic performance of three experienced radiologists in their interpretation of renal artery angiograms indicates that the intra- and inter-observer agreement with respect to their estimates of the degree of stenosis and the site of greatest stenosis are rather poor but their diagnostic performance improves in patients with stenosis and a renin ratio greater than 1.5. There is a need for more objective assessment of renal artery lesions.

Angiography↗

Cartilage MR imaging at 3.0 versus that at 1.5 T: preliminary results in a porcine model.

PURPOSE: To compare 1.5- and 3.0-T magnetic resonance (MR) images of porcine knee specimens containing artificial cartilage lesions in terms of accuracy of lesion depiction, image quality, and signal-to-noise ratio (SNR). MATERIALS AND METHODS: This Health Insurance Portability and Accountability Act-compliant study had institutional review board approval, and informed consent was obtained from the human volunteers. Two fat-saturated cartilage MR imaging sequences (an intermediate-weighted fast spin-echo [SE] sequence and a spoiled gradient-echo [GRE] sequence) were optimized for imaging at 3.0 T in two human volunteers and then used to image 10 porcine knees in which 29 artificial cartilage lesions had been created. Corresponding sequences were used at 1.5 T for all specimens. Images were assessed by two radiologists in consensus, and diagnostic performance in lesion depiction was determined by using macroscopic findings in specimen slices as a reference standard. SNRs were also calculated. For statistical analysis, the McNemar test of discordant pairs was used with a level of significance of P < .05. RESULTS: The best diagnostic performance for both the intermediate-weighted fast SE and the spoiled GRE sequences was achieved at 3.0 T. With use of corresponding fat-saturated intermediate-weighted fast SE sequences with an identical acquisition time (9 minutes 44 seconds), 26 (90%) of 29 lesions were detected at 3.0 T, while 18 (62%) were detected at 1.5 T. With use of fat-saturated spoiled GRE sequences, 24 (83%) of 29 lesions were detected at 3.0 T (acquisition time, 8 minutes 48 seconds), and 23 (79%) lesions were detected at 1.5 T (acquisition time, 11 minutes 14 seconds). The rate of correct lesion grade assessment was 65% (17 of 26 lesions) at 3.0 T and 61% (11 of 18 lesions) at 1.5 T with the intermediate-weighted fast SE sequences and 83% (20 of 24 lesions) at 3.0 T and 70% (16 of 23 lesions) at 1.5 T with the spoiled GRE sequences. Both subjective evaluation of image quality and SNR values were significantly higher at 3.0 T (P < .05). CONCLUSION: In this animal model, MR imaging at 3.0 T increased the accuracy of cartilage lesion assessment when compared with imaging at 1.5 T. Image quality and SNR were highest at 3.0 T.

Animals↗

[The value of contrast in stress echocardiography].

Stress echocardiography is a well validated method of diagnosing myocardial ischaemia and viability. Its limitations are also well known, related to a subjective interpretation and lack of reproducibility. One of the solutions suggested to improve its diagnostic performance is the use of ultrasonic contrast agents which presents many advantages. In difficult patients, the left ventricular chamber may be opacified, both at rest and at peak effort with a significant improvement in the detection of the endocardial contour and in the reproducibility of the interpretation of the images. The diagnostic performance of stress echocardiography with contrast is less dependent on the conditions of observation. In addition, recent technical advances enable the same ultrasonic contrast agents to be used for the study of myocardial perfusion. The first clinical studies using these techniques report the feasibility of simultaneous analysis of wall motion abnormalities and myocardial perfusion on exercise. Further progress is expected to facilitate the interpretation and quantification of these investigations which should further increase the diagnostic value of stress echocardiography.

Contrast Media↗

A statistical approach to the evaluation of covariate effects on the receiver operating characteristic curves of diagnostic tests in glaucoma.

PURPOSE: To describe an approach for the evaluation of covariate effects on receiver operating characteristic (ROC) curves and to apply this methodology to the investigation of the effects of disease severity and age on the diagnostic performance of frequency doubling technology (FDT) and standard automated perimetry (SAP) visual function tests for glaucoma detection. METHODS: The study included 370 eyes of 211 participants, with 174 eyes of 110 patients having glaucomatous optic neuropathy and 196 eyes of 101 subjects being normal. All patients underwent visual function testing with FDT 24-2 Humphrey Matrix and SAP SITA (Carl Zeiss Meditec, Inc., Dublin, CA). Disease severity was evaluated by the amount of neuroretinal rim loss assessed by confocal scanning laser ophthalmoscopy. An ROC regression model was fitted to evaluate the influence of disease severity and age on the diagnostic performance of the pattern SD (PSD) index from FDT 24-2 and SAP SITA. RESULTS: After adjustment for age, the areas under the ROC curves (AUCs) for SAP SITA PSD for 10%, 30%, 50%, and 70% loss of neuroretinal rim area were 0.638, 0.756, 0.852, and 0.920, respectively. Corresponding values for FDT 24-2 PSD were 0.766, 0.857, 0.922, and 0.962. For 10% and 30% rim loss, FDT 24-2 PSD had a significantly larger AUC than did SAP SITA PSD. CONCLUSIONS: A regression methodology to evaluate covariate effects on ROC curves can be useful for assessment of diagnostic tests in glaucoma. Using the proposed methodology, a significantly better performance of FDT 24-2 compared to SAP SITA for diagnosis of early glaucoma was demonstrated.

Age Factors↗

A new scoring system to differentiate benign from malignant adnexal masses.

OBJECTIVE: The purpose of this study was to develop and cross-validate a new sonographic scoring system for differentiation between benign and malignant adnexal masses. STUDY DESIGN: This study was conducted in a tertiary care university hospital. In the first part of the study, we used a multivariate logistic regression analysis to develop a scoring system that was based on morphologic and Doppler sonographic data for 705 adnexal masses in 665 patients who were diagnosed and treated at our institution from January 1995 to June 2001. The scoring system was designed to use only those parameters that are found to be independent predictors of malignancy. In the second part of the study, we prospectively cross-validated this scoring system in a series of 90 adnexal masses in 86 patients between July 2001 and March 2002. With the use of the area under the curve of the respective ROC curves, we compared the new scoring system with other scoring systems. RESULTS: Multivariate logistic regression analysis revealed that the only independent predictor parameters were thick papillary projections, solid areas, central flow, and velocimetric features of high velocity and low resistance. In the prospective cross-validation study, our scoring system had the best diagnostic performance (area under the curve, 0.98) compared with Sassone (area under the curve, 0.89; P =.017), De Priest (area under the curve, 0.92; P =.048), and Ferrazzi (area under the curve, 0.90; P =.013) scoring systems. CONCLUSION: Our new sonographic scoring system had a better diagnostic performance than three previously published scoring systems.

Adnexa Uteri↗

Determining the optimal number of specimens to obtain with needle biopsy of the pleura.

The aim of this study was to define the number of pleural biopsy samples necessary for optimum diagnostic performance and determine to what extent they are complementary. Eighty-four closed pleural biopsies were performed in our department between June 1996 and January 1998 on 55 males and 29 females with an average age of 64.4 +/- 16.7 years. The study of the pleural fluid included: pH, biochemical testing of pleura/serum (proteins, lactate dehydrogenase, glucose, cholesterol, triglycerides, albumin and adenosine deaminase), haemogram, cytology and microbiological testing (Gram-staining, aerobes, anaerobes and mycobacteriae cultures). The biopsies were performed using a Cope needle, with a total of five biopsies for each patient: four for pathological examination (taken numerically in the order in which they were performed: D1, D2, D3 and D4) and one for microbiological testing. In those cases in which the diagnosis was uncertain or effusion persisted, a thoracoscopy or thoracotomy was performed. There were no significant differences in the diagnostic yield of each individual sample (D1, D2, D3 and D4), but there were differences in the sum of the samples, depending on the number of biopsies performed.This was true for total group and the group with carcinomas, but not for the group with tuberculosis. The increase in diagnostic yield with the number of biopsies was more remarkable in the carcinoma cases, where it increased by 35% when four biopsies were performed (54% with one biopsy versus 89% with four biopsies, P < 0.002). In conclusion, the diagnostic yield increased with the number of biopsy samples in the total group and the group with malignancy but not in the group with tuberculous effusions. The best diagnostic performance for malignant pathology was obtained with four samples. In pleural tuberculosis, the diagnostic yield did not increase with more biopsy samples. One high quality sample should be enough to obtain a diagnosis.

Aged↗

A proposal of new ocular items in Sjögren's syndrome classification criteria.

OBJECTIVE: To verify whether ocular surface tests other than those included in primary Sjögren's syndrome (SS-I) classification criteria (Schirmer I, Break up Time, vital dye staining) may contribute to SS I diagnosis. METHODS: Two hundred and sixty-two patients (78 SS-1, 91 non-SS autoimmune diseases, 93 Sicca syndrome) filled a validated questionnaire on symptoms and were evaluated by Schirmer test without (Schirmer I) and with (Jones test) topical anaesthesia, Break Up Time (BUT), corneal aesthesiometry, tear clearance rate, vital dye (lissamine green) staining, impression conjunctival cytology, concentration of tear lysozyme and lactoferrin. Thresholds were selected from Receiver Operating Curves; sensitivity, specificity, likelihood ratio (LR+), predictive values were calculated for each test. A logistic regression model was constructed representing the best diagnostic index for SS. RESULTS: Data showed a poor diagnostic performance of Schirmer test I (LR+ 1.38) and BUT (LR+ 1.05); results from lissamine green staining may be unreliable due to incorporation bias. Tear lactoferrin (LR+ 4.52), Jones test (LR+ 6.24), tear lysozyme (LR+ 8.0), symptom questionnaire (LR+ 8.62), tear clearance rate (LR+ 18.73) and corneal aesthesiometry (LR+ 20.96) exhibited high diagnostic performance also taken together in the regression model. CONCLUSION: Because many of the tests we have screened in this study can be carried out by a trained ophthalmologist in any clinical setting, we recommend that ocular surface impairment is studied with the combination of tests proved to be helpful for the SS I diagnosis.

Aged↗

Improved immunoglobulin M serodiagnosis in Lyme borreliosis by using a mu-capture enzyme-linked immunosorbent assay with biotinylated Borrelia burgdorferi flagella.

A mu-capture enzyme-linked immunosorbent assay (ELISA) for detection of serum immunoglobulin M (IgM) antibodies to Borrelia burgdorferi by using biotinylated purified B. burgdorferi flagella was developed. The diagnostic performance of the mu-capture ELISA was compared with that of a conventional indirect ELISA. Sera from untreated patients with erythema migrans (n = 50), neuroborreliosis (n = 100), and acrodermatitis chronica atrophicans (ACA; n = 48) were investigated. The cutoff of the ELISAs was adjusted to a diagnostic specificity of 98% on the basis of examination of 200 serum specimens from healthy controls. The mu-capture ELISA increased the diagnostic sensitivity in patients with erythema migrans from 32 to 48% (P less than 0.01) and in patients with neuroborreliosis from 37 to 57% (P less than 0.001). Because of an increased signal/noise ratio, the mu-capture ELISA yielded a significantly better quantitative discrimination of individual positive measurements from the cutoff (P less than 0.001). The increased signal/noise ratio was most likely a consequence of the elimination of IgG competition for the test antigen. This may also explain why 12% of patients with ACA showed significantly increased specific IgM levels only by the mu-capture ELISA. Of patients with ACA, 27% had IgM rheumatoid factor. The mu-capture principle with a directly labeled antigen showed no interference with IgM rheumatoid factor, in contrast to the indirect ELISA. The high diagnostic performance and ease of this three-step mu-capture ELISA make it suitable for routine anti-B. burgdorferi IgM serodiagnosis.

Adolescent↗

Monte Carlo study of grid performance in diagnostic radiology: task dependent optimization for screen-film imaging.

An optimization of anti-scatter grid design using Monte Carlo techniques in diagnostic radiology is presented. The criterion for optimization was to find the combinations of the grid parameters (lead strip width, grid ratio and strip density) and tube potential which result in the lowest mean absorbed dose in the patient at fixed image contrast. The optimization was performed in three irradiation geometries, representing different scattering conditions (paediatric examinations, and two adult lumbar spine examinations) and was restricted to grids using fibre materials in covers and interspaces. Grid designs currently available were studied, as were designs which use thinner strips (< 30 microns) and higher grid ratios (> 18). It was found that grids with widely different strip densities (strips cm-1) and grid ratios can have good performance provided that they are used with appropriate strip width and tube potential. With increasing amounts of scatter, the optimal grid requires thicker strips and higher grid ratios. Increasing the strip density and using thinner strips and higher grid ratios are generally required. Grids with low strip density (25 strips cm-1) were found to be less sensitive to alterations in strip width. Optimal grids for paediatric radiology require thinner strips (10-20 microns) than those in currently available grids. Grids on the market are best suited for examinations of the adult body in anteroposterior (AP) view. In the adult lateral view, representing the largest scattering volume, higher grid ratios (> 18) than those in existing grids would be optimal. Examples of good grid designs are given for each examination.

Adult↗

Computerized tomography colonography.

First introduced a decade ago, computerized tomography (CT) colonography (virtual colonoscopy) is emerging as an important radiologic investigation for colorectal neoplasia, with diagnostic performance likely exceeding barium enema and comparable with optical colonoscopy. Employing state-of-the-art multislice technology, CT colonography allows a complete examination of the colon and surrounding organs in less than 30 seconds. This article reviews current techniques, indications, comparison with existing technologies, and diagnostic performance. Although already widely disseminated, important future developments, such as prepless bowel cleansing (laxative free) and computer-aided diagnosis, may establish CT colonography as the preferred first-line, whole-colon investigation.

Accreditation↗

Evaluation of white blood cell concentration, plasma fibrinogen concentration, and an agar gel immunodiffusion test for early identification of foals with Rhodococcus equi pneumonia.

OBJECTIVE: To evaluate WBC concentration, plasma fibrinogen concentration, and an agar gel immunodiffusion (AGID) test for early identification of Rhodococcus equi-infected foals. DESIGN: Prospective study. ANIMALS: 162 foals from a farm with enzootic R equi infection. PROCEDURE: Blood samples were obtained from each foal at 4-week intervals for measurement of WBC and plasma fibrinogen concentrations and at 2-week intervals for detection of anti-R equi antibody by an AGID assay. Diagnostic performance of WBC and fibrinogen concentrations was assessed by use of receiver operating characteristic curve analysis. For each assay, sensitivity, specificity, and predictive values were calculated at various cutoff points; bacteriologic culture of R equi from a tracheobronchial aspirate was used as the reference standard test. RESULTS: Diagnostic performance of WBC concentration was significantly higher than that of fibrinogen concentration. Sensitivity and specificity of measurement of WBC concentration at a cutoff of 13,000 cells/microL were 95.2 and 61.2%, respectively; at a cutoff of 15,000 cells/microL, sensitivity was 78.6% and specificity was 90.8%. When a positive test result was used as the cutoff, sensitivity of the AGID assay was 62.5% and specificity was 53.8%. CONCLUSION AND CLINICAL RELEVANCE: Monitoring WBC concentration is a useful approach for early detection of infected foals on farms with a high prevalence of R equi pneumonia. In contrast, serologic surveillance by use of an AGID assay is of little benefit for that purpose.

Actinomycetales Infections↗

A self-report scale to help make psychiatric diagnoses: the Psychiatric Diagnostic Screening Questionnaire.

BACKGROUND: The Psychiatric Diagnostic Screening Questionnaire (PDSQ) is a brief, psychometrically strong, self-report scale designed to screen for the most common DSM-IV Axis I disorders encountered in outpatient mental health settings. In the present report, we describe the diagnostic performance (sensitivity, specificity, and positive and negative predictive values) of the PDSQ in an outpatient setting. METHODS: Six hundred thirty psychiatric outpatients presenting for treatment were evaluated with the Structured Clinical Interview for DSM-IV after completing the PDSQ. Patients arrived approximately 20 minutes before the scheduled time of the appointment to complete the scale. Diagnostic raters were blind to responses on the scale. RESULTS: The PDSQ's subscales' diagnostic performance varied in a predictable manner according to the cutoff score-as the threshold for case identification increased, subscale sensitivity decreased and specificity increased. Mean subscale sensitivities of 80%, 85%, and 90% resulted in mean subscale specificities of 78%, 73%, and 66%, respectively, and negative predictive values of 95%, 96%, and 97%. Receiver operating curves were determined for each subscale and all areas under the curve were significant. CONCLUSIONS: The PDSQ is a diagnostic aid designed to be used in clinical practice to facilitate the efficiency of conducting initial diagnostic evaluations. From a clinical perspective, it is most important that a diagnostic aid have good sensitivity, so that most cases are detected, and high negative predictive value, so that most noncases on the measure are indeed noncases. Our results indicate that most of the PDSQ subscales were able to achieve this goal.

Adult↗

Coronary angiogram and intervention through transulnar approach.

BACKGROUND: This study was conducted to assess the safety and feasibility of a transulnar approach in performing diagnostic and interventional percutaneous coronary procedures. METHODS AND RESULTS: In the year 2004, a total of 100 patients underwent diagnostic angiography (n=64) and percutaneous coronary interventions (n=36) through transulnar approach. The patients' age ranged from 40 to 70 years and male to female ratio was 7.3:1. The cases of percutaneous coronary interventions were mostly elective procedures and emergency intervention was done in only 2 patients. The procedure was successful in 95 (95%) patients and unsuccessful in 5 (4 diagnostic and 1 percutaneous coronary intervention). The procedure was done through right ulnar artery in all except one patient in whom it was done through left ulnar artery. The total procedure time ranged between 25-45 min. Among the cases of percutaneous coronary interventions, single vessel angioplasty was performed in 23 (65.7%) patients, double vessel in 11 (31.4%) patients and triple vessel in 1 (3%) patient. All percutaneous coronary intervention patients received aspirin, clopidogrel and intravenous enoxaparin. Glycoprotein IIb/IIIa inhibitors were used in 7 patients. Complications such as local hematoma, ulnar artery perforation and reversible parasthesia occurred in one patient each. CONCLUSIONS: Tansulnar approach is a safe and easy alternative technique to perform diagnostic and therapeutic coronary interventions.

Adult↗

Diagnosis and management of blunt small bowel injury: a survey of the membership of the American Association for the Surgery of Trauma.

BACKGROUND: Blunt small bowel injury (SBI) may be difficult to diagnose accurately. Diagnostic delays are associated with increased morbidity and mortality. METHODS: A cross-sectional survey of members of the American Association for the Surgery of Trauma was conducted. A Likert-type multiple-choice scale was used to evaluate use and usefulness of diagnostic and laboratory tests. Data were analyzed by using univariate and multivariate techniques. RESULTS: A total of 461 of the 702 members (68%) surveyed responded, of which 133 members (29%) were excluded because they did not currently manage adult SBI. Of the remaining 328 respondents, 244 members (74%) reported prior experience as the most important influence on their current practice of diagnosing blunt SBI. None of the standard laboratory tests were reported as useful. Seventy-seven percent of respondents use computed tomographic (CT) scan most or all of the time for diagnosis (p < 0.05 compared with other modalities). Most respondents estimated their annual incidence of SBI at 5% with a >15% frequency of delay in diagnosis. Forty-four percent of the respondents estimated the mortality associated with a delay in diagnosis at < or =5%. Respondents varied significantly in their management of the patient with an unreliable abdominal exam and a CT scan finding of isolated free fluid. In patients with head injuries, 28% observe, 12% repeat the CT scan, 42% perform diagnostic peritoneal lavage, and 16% operate. For intoxicated patients, 51% observe, 11% repeat the CT scan, 26% perform diagnostic peritoneal lavage, and 10% operate. A more aggressive approach with diagnostic and operative intervention was significantly (p < 0.05) advocated by respondents practicing without residents, more than 15 years out from residency, or by those with a perception of higher morbidity and mortality from delays in diagnosis. CONCLUSION: There is significant variation in the diagnostic approach to the patient with suspected SBI. The perceived mortality of delayed diagnosis is much less than reported. Those surgeons with more experience or perception of greater morbidity and mortality from a delayed diagnosis are more aggressive. Further investigation into the diagnosis and treatment of this injury is needed.

Abdominal Injuries↗

Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris.

OBJECTIVES: This study was designed to prospectively evaluate the diagnostic performance of multislice spiral computed tomography (MSCT) coronary angiography for the detection of significant lesions in all segments of the coronary tree potentially suitable for revascularization. BACKGROUND: Noninvasive MSCT coronary angiography is a promising coronary imaging technique. METHODS: Sixteen-row MSCT coronary angiography was performed in 128 patients (89% men, mean age 58.9 +/- 11.7 years) in sinus rhythm with stable angina pectoris scheduled for conventional coronary angiography. Sixty percent (77 of 128) of patients received pre-scan oral beta-blockers, resulting in a mean heart rate of 57.7 +/- 7.7 beats/min. The diagnostic performance of MSCT for detection of significant lesions (> or =50% diameter reduction) was compared with that of quantitative coronary angiography (QCA). RESULTS: The sensitivity of MSCT for detection of significant lesions was 92% (216 of 234, 95% confidence interval [CI]: 88 to 95). Specificity was 95% (1,092 of 1,150, 95% CI: 93 to 96), positive predictive value 79% (216 of 274, 95% CI: 73 to 88), and negative predictive value 98% (1,092 of 1,110, 95% CI: 97 to 99). Two > or =50% lesions were missed because of motion artifacts and two because of severe coronary calcifications. The rest (78%, 14 of 18) were detected but incorrectly classified as <50% obstructions. All patients with and 86% (18 of 21) of patients without significant lesions on QCA were correctly classified by MSCT. All patients with significant left main disease or total occlusions were correctly identified on MSCT. CONCLUSIONS: Sixteen-row MSCT coronary angiography permits reliable detection of significant obstructive coronary artery disease in patients with stable angina in sinus rhythm.

Aged↗

What is the most sensitive non-invasive imaging strategy for the diagnosis of intracranial aneurysms?

OBJECTIVES: To determine whether combining non-invasive tests for intracranial aneurysms together would significantly improve aneurysm detection over individual tests. METHODS: 114 patients undergoing intra-arterial digital subtraction angiography to confirm or exclude an intracranial aneurysm were also examined by CT angiography, MR angiography, and transcranial power Doppler ultrasound. The reviewers and ultrasonographers were blinded to the angiogram result, other imaging results and all clinical information. RESULTS: The combination of non-invasive tests did improve diagnostic performance on a per patient basis. The combination of power Doppler and CT angiography had the greatest sensitivity for aneurysm detection (0.83; 05% confidence interval (95% CI) 0.66-0.93) and the level of agreement for this strategy with the reference angiographic standard was excellent (kappa 0.84; 95% CI 0.72-0.95). The improvement in sensitivity of adding power Doppler to CT angiography was not significant (p=0.55) but the improvement in the level of agreement with the reference standard was substantial. However, even the most sensitive combination strategy performed poorly in the detection of small (3-5 mm) and very small (<3 mm) aneurysms with a sensitivity of 0.43 (95% CI 0.23-0.66) and 0.00 (95% CI 0.00-0.31) respectively. CONCLUSIONS: The addition of transcranial power Doppler ultrasound to either CT angiography or MR angiography does improve diagnostic performance on a per patient basis but aneurysms of 5 mm or smaller can still not be reliably identified by current standard clinical non-invasive imaging modalities.

Adult↗