Feasibility of endocardial edge detection by using an inversion recovery artifact.

An inversion recovery (IR) artifact was used to delineate the blood/wall boundary in left ventricles. The artifact consisted of a hypointensity signal in pixels located at the boundary of two contiguous tissues with different T(1) relaxation times. The feasibility of measuring the ejection fraction using the artifact was tested in ten healthy volunteers, with two IR snapshot-FLASH sequences possessing different times of repetition (TR = 11msec and TR = 3.5msec) and appropriate times of inversion. The comparison with a cine-MRI sequence showed that ejection fraction measurements are feasible when performed with a snapshot-FLASH sequence that has a sufficiently short TR (3.5msec).

Adult↗

Metallic neurosurgical implants: evaluation of magnetic field interactions, heating, and artifacts at 1.5-Tesla.

The purpose of this study was to use ex vivo testing to determine the magnetic resonance imaging (MRI) safety aspects for seven different metallic neurosurgical implants in association with the 1.5-T MR environment. Ex vivo testing was performed using previously-described techniques for the evaluation of magnetic field interactions (deflection angle and torque), heating (gel-filled phantom and fluoroptic thermometry; 15 minutes of MRI at a specific absorption rate [SAR] of 1.4 W/kg), and artifacts (using T1-weighted, spin-echo and gradient-echo pulse sequences). None of the metallic implants displayed interactions with the magnetic field. The highest temperature change was +0.6 degrees C for the representative implant that was evaluated. Artifacts were relatively minor. The lack of magnetic field interactions and negligible heating indicate that MR procedures may be conducted safely in patients with these neurosurgical implants using MR systems with static magnetic fields of 1.5-T or less. Furthermore, these implants may be considered for use in interventional MR procedures insofar as the MR safe qualities and relatively small artifacts would likely be desirable for such procedures.

Artifacts↗

Pulsatile flow artifacts in two-dimensional time-of-flight MR angiography: initial studies in elastic models of human carotid arteries.

Initial experimental and numerical analysis of artifacts due to pulsatile flow in two-dimensional time-of-flight (2D-TOF) magnetic resonance (MR) angiography are presented. The experimental studies used elastic models of the carotid artery bifurcation cast from fresh cadavers and accurately reproducing the twisting and tapering of the human blood vessels, allowing direct comparison of images with and without flow. Prominent image artifacts, including periodic ghosts and signal loss, were produced by pulsatile flow even though flow-compensated gradient waveforms were used. The dependence of artifacts due to partial saturation on pulse sequence parameters (TR and flip angle) was investigated theoretically for a simple pulsatile velocity profile and compared with experimental results from a model of a normal carotid artery. Signal reduction was observed proximal and distal to the stenosis in a model with a 70% internal carotid artery (ICA) stenosis and a model with 90% stenoses in both the ICA and the external carotid artery. Although this study deals exclusively with 2D-TOF imaging, the methods can also be applied to evaluate other MR angiography techniques.

Artifacts↗

Reduction of ringing and blurring artifacts in fast spin-echo imaging.

A simple method was devised to reduce ringing and blurring artifacts caused by discontinuous T2 weighting of k-space data in fast spin-echo magnetic resonance (MR) imaging. The method demodulates the weighting function along the phase-encoding direction by using multiple T2 values derived from a set of non-phase-encoded echoes obtained from an extra excitation. The performance of this method was evaluated by computer simulations and experiments, which confirmed its capability of effectively reducing or, in some cases, even completely removing the ringing and blurring artifacts. The results also show that the proposed method produces better results than other artifact reduction methods. The method is particularly useful at high magnetic field strengths (7.1-9.4 T) and with strong gradients (> 20 G/cm) used in MR microscopy, in which the apparent T2 values are short for most tissues. The authors expect that the proposed method will find useful applications in various fast spin-echo pulse sequences.

Artifacts↗

Ex vivo evaluation of ferromagnetism and artifacts of cardiac occluders exposed to a 1.5-T MR system.

Magnetic resonance (MR) procedures are contraindicated for patients with certain ferromagnetic biomedical implants, primarily owing to the risk of movement or dislodgment of the implants by the static magnetic field. An additional concern is the amount of artifact that the implant produces, which can affect image quality and interpretation of the examination. Therefore, an ex vivo assessment of ferromagnetism and artifact was conducted for 12 different occluders used to treat patients with patent ductus arteriosus, atrial septal defects, and ventricular septal defects, in a 1.5-T MR system. Seven of the occluders, made of 304 stainless steel, were ferromagnetic and displayed deflection forces of 248-299 dynes. Five of the implants, made of MP35n, were nonferromagnetic. Artifacts were variable and depended primarily on the type and amount of metal used to construct the implant. The authors conclude that patients with ferromagnetic cardiac occluders may undergo MR procedures approximately 6 weeks after placement of these devices, to allow tissue growth to provide additional retentive force. After this time, it is highly unlikely that the magnetic fields associated with a 1.5-T MR system are capable of moving or dislodging any of these cardiac occluders.

Alloys↗

Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography.

Partial-volume artifacts reduce vessel contrast and continuity (especially in small vessels) in magnetic resonance (MR) angiography. The authors applied zero-filled (band-limited) interpolation to three-dimensional (3D) MR angiograms to reduce partial-volume artifacts. They demonstrated that zero-filled interpolation can also be implemented by means of voxel shifting in real space. Voxel-shifted interpolation is much less computer memory intensive than conventional zero-filled interpolation. They numerically simulated the contrast loss due to partial-volume artifacts and contrast recovery obtained with zero-filled interpolation. Zero-filled interpolation in all three orthogonal directions was applied to 3D MR angiography data sets from 29 human studies. These studies were obtained with the three commonly used 3D MR angiography techniques: 3D time of flight, multislab 3D time of flight, and 3D phase contrast. A substantial improvement in vessel contrast and vessel continuity was observed in all cases.

Adult↗

Biopsy needles and devices: assessment of ferromagnetism and artifacts during exposure to a 1.5-T MR system.

Forty-eight biopsy devices (needles, stylets, guide wires, biopsy guns, etc) were evaluated for ferromagnetism (n = 48) and artifacts (n = 43) in a 1.5-T magnetic resonance (MR) system, with previously described techniques. Forty-five of the 48 devices were found to be ferromagnetic. Artifacts varied, depending on the type and size of the component material(s) of the device. Most of the commercially available biopsy devices are not useful for MR imaging-guided biopsy procedures because of the presence of ferromagnetism and associated artifacts.

Artifacts↗

Hybrid ordered phase encoding (HOPE): an improved approach for respiratory artifact reduction.

Respiration causes continuous change in cardiac position, which leads to image degradation. Phase-encode reordering methods are often used to reduce these artifacts. An improved method for suppressing motion artifacts by reordering the acquisition of k space has been developed that is less sensitive to change of breathing patterns and bulk movement. We describe the theory behind the new approach and compare its results with those of existing methods by use of a phantom with simulated and actual acquired breathing patterns. The comparison was also made in vivo; cardiac scans were performed in 15 subjects with image planes that are known to be particularly susceptible to respiratory artifact. A significant improvement in image quality was achieved compared with conventional nonreordered and existing reordering methods.

Algorithms↗

Artifacts and pitfalls in diffusion MRI.

Although over the last 20 years diffusion MRI has become an established technique with a great impact on health care and neurosciences, like any other MRI technique it remains subject to artifacts and pitfalls. In addition to common MRI artifacts, there are specific problems that one may encounter when using MRI scanner gradient hardware for diffusion MRI, especially in terms of eddy currents and sensitivity to motion. In this article we review those artifacts and pitfalls on a qualitative basis, and introduce possible strategies that have been developed to mitigate or overcome them.

Artifacts↗

Origin and minimization of residual motion-related artifacts in navigator-corrected segmented diffusion-weighted EPI of the human brain.

Motion sensitivity in diffusion-weighted imaging (DWI) can be effectively suppressed using single-shot echo-planar imaging (EPI). However, segmented (multishot) EPI is often used to increase resolution and reduce spatial distortions, which in turn increases susceptibility to brain motion. The sources of these residual motion artifacts in navigator-echo-corrected segmented EPI images of the brain were investigated. The results indicate that the dominant source of these artifacts is cardiac pulsation with occasional involuntary movement of the subject. The relationship between the cardiac cycle and motion artifacts shows that optimum timing for the data acquisition is possible. In addition it is shown that the effects of involuntary motion can be removed by swapping k-space data between redundant datasets.

Artifacts↗

Using UNFOLD to remove artifacts in parallel imaging and in partial-Fourier imaging.

In dynamic MRI, it is often difficult to achieve the acquisition speed required to resolve or freeze the temporal variations of the imaged object. Several MRI methods aim at speeding up the image acquisition process. Through assumptions and/or prior knowledge, these dynamic MRI methods allow part of the needed data to be calculated instead of acquired. For example, partial-Fourier imaging assumes that phase varies smoothly within the object, and parallel imaging (e.g., simultaneous acquisition of spatial harmonics (SMASH) and sensitivity encoding (SENSE)) uses prior knowledge about receiver-coil sensitivity. While these methods accelerate acquisition, they can introduce artifacts or amplify noise in doing so. The present work aims at accelerating image acquisition significantly, while introducing almost no artifacts or noise amplification. It is shown here that new, extra information is gained if dynamic MRI methods are modified so that the sampling function changes in specific ways from time-frame to time-frame. In other words, the set of k-space locations that are acquired (instead of calculated) changes with time. The present temporal strategy, based on the UNaliasing by Fourier-encoding the Overlaps in the temporaL Dimension (UNFOLD) method, can be incorporated into common dynamic MRI methods. Results with partial-Fourier, SMASH, and SENSE imaging are presented here, where UNFOLD's contribution is to very significantly reduce the artifact and/or amplified noise content. Used in this way, UNFOLD contributes indirectly, rather than directly to the improvement in image acquisition speed, as it allows companion methods to operate properly at greater acceleration settings than would otherwise be feasible.

Artifacts↗

Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency.

The presence of resonance frequency offsets often causes artifacts in images acquired with true fast imaging with steady-state precession (true-FISP). One source of resonance offsets is a suboptimal setting of the synthesizer frequency. The goal of this work was to demonstrate that shifting the synthesizer frequency could minimize the off-resonance related image artifacts in true-FISP. A simple scouting method was developed to estimate the optimal synthesizer frequency for the volume of interest (VOI). To improve fat suppression, a similar scouting method was also developed to determine the optimal frequency offset for the fat saturation pulse. Coronary artery imaging was performed in healthy subjects using a 3D true-FISP sequence to validate the effectiveness of the frequency corrections. Substantial reduction in image artifacts and improvement in fat suppression were observed by using the water and fat frequencies estimated by the scouting scans. Frequency shifting is a useful and practical method for improving coronary artery imaging using true-FISP.

Adult↗

Artifact due to B(0) fluctuations in fMRI: correction using the k-space central line.

Magnetic resonance experiments require the main magnetic field, B(0), to remain very stable. Several external sources, such as moving ferromagnetic objects and/or changing electromagnetic fields, can significantly change the value of B(0) over time. This work describes an apparent displacement along the phase-encoding axis caused by a variation in B(0). This artifact was observed in fMRI images acquired with EPI. The effect was characterized and tested using an immobile phantom. The image displacement motion along the phase-encoding axis closely followed the changes in B(0). The phase of the central line in the Fourier space was successfully used to correct this artifact. Fluctuations in B(0) may result in artifacts that mimic subject head motion, and must be appropriately corrected. Magn Reson Med 46:198-201, 2001.

Algorithms↗

IMPACT: image-based physiological artifacts estimation and correction technique for functional MRI.

Functional MRI (fMRI) signal variation induced by respiratory and cardiac motion affects the activation signal and limits the accuracy of analysis. Current physiological motion correction methods require either synchronization with external monitoring of respiration and heartbeat, specialized pulse sequence design, or k-space data. The IMage-based Physiological Artifacts estimation and Correction Technique (IMPACT), which is free from these constraints, is described. When images are acquired fast enough to sample physiological motion without aliasing, respiratory and cardiac signals can be directly estimated from magnitude images. Physiological artifacts are removed by reordering images according to the estimated respiratory and cardiac phases and then subtracting the Fourier-fitted variation from magnitude images. Compared with the k-space-based method, this method can efficiently and effectively reduce the overall signal fluctuation in the brain and increase the activated area. With this new technique, physiological artifacts can be reduced using traditional fMRI pulse sequences, and existing data can be corrected and reanalyzed without additional experiments.

Adult↗

FLAIR imaging using nonselective inversion pulses combined with slice excitation order cycling and k-space reordering to reduce flow artifacts.

High-signal artifacts produced by cerebrospinal fluid (CSF) flow can adversely affect fluid-attenuated inversion recovery (FLAIR) imaging of the brain and spinal cord. This study explores the use of a nonslice-selective inversion pulse to eliminate CSF flow artifacts together with a technique called "K-space Reordered by Inversion-time for each Slice Position" (KRISP) to achieve constant contrast in a multislice acquisition. Theory shows that with this method the CSF point spread function (PSF) has a minimum at the center and attenuated side lobes, providing CSF suppression, but residual edge signals remain. The PSF for brain is only mildly attenuated and signals for extended regions are not attenuated. KRISP FLAIR sequences were assessed in 15 patients (10 brain and five spinal cord cases). The images showed reduced CSF and blood flow artifacts and higher conspicuity of the cortex, meninges, ventricular system, brainstem, and cerebellum when compared with conventional FLAIR sequences.

Adult↗

Elimination of oblique flow artifacts in magnetic resonance imaging.

We present an analysis of how flow oblique to the frequency-encoding direction generates displacement artifacts in MR imaging and show that for flow which has constant velocity between the start of the phase encoding and the center of the echo it is possible to eliminate these artifacts by gradient moment nulling in the phase-encoding direction. However, unlike the standard moment nulling calculations for flow compensating the frequency-encode and slice-selection gradients, the phase-encoding first moment must be nulled specifically with respect to the echo center. Limitations of this method imposed by finite gradient strengths are analyzed. In 3D volume acquisitions with two axes phase encoded it is possible to correct for oblique flow in all directions, and this is demonstrated in images of a human volunteer. Correction for oblique flow displacement artifacts may be particularly useful in quantitative flow and angiographic applications.

Artifacts↗

Artifacts and signal loss due to flow in the presence of B(o) inhomogeneity.

An in vitro study was performed to investigate the effects of B(o) inhomogeneity on magnetic resonance images of flow. Controlled inhomogeneity gradients (Gi) were applied and the magnitude of the artifacts produced was quantified for different echo delay times (TE). Both steady and pulsatile flows were examined. In the presence of an inhomogeneity gradient, signal loss is apparent if the flow is pulsatile and/or if the slice thickness is large. The signal loss increases with increasing TE and Gi. With pulsatile flow, ghosting artifacts are also generated. These increase in intensity with increasing TE and Gi. In vivo, field inhomogeneity due to susceptibility variations is large enough to produce these effects. Representative time-of-flight images obtained of a normal volunteer with two different TEs demonstrate the effect in vivo. Flow-related signal loss and artifacts, therefore, increase with increasing TE independent of the moments of the applied gradients.

Artifacts↗

A forward-subtraction procedure for removing hyperfine artifacts in electron paramagnetic resonance imaging.

The potential for using electron paramagnetic resonance (EPR) imaging in biological applications has been limited by the lack of ideal single-line imaging probes. The commonly used nitroxides exhibit multiple lines, causing either hyperfine-based limitations in the maximum obtainable image resolution or hyperfine-based artifacts in the reconstructed image. The application of a numerical method, based on forward-subtraction principles for removing hyperfine artifacts in the measured projections is reported. It is demonstrated by using computer simulations, imaging of phantoms, and imaging of rat hearts, that marked enhancement in image quality and resolution can be obtained by removing the hyperfine-imposed limit on the gradient magnitude and performing postacquisition corrections for removing hyperfine artifacts in the image.

Animals↗