Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Sequencing quality”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Controlling false-negative errors in microarray differential expression analysis: a PRIM approach.

MOTIVATION: Theoretical considerations suggest that current microarray screening algorithms may fail to detect many true differences in gene expression (Type II analytic errors). We assessed 'false negative' error rates in differential expression analyses by conventional linear statistical models (e.g. t-test), microarray-adapted variants (e.g. SAM, Cyber-T), and a novel strategy based on hold-out cross-validation. The latter approach employs the machine-learning algorithm Patient Rule Induction Method (PRIM) to infer minimum thresholds for reliable change in gene expression from Boolean conjunctions of fold-induction and raw fluorescence measurements. RESULTS: Monte Carlo analyses based on four empirical data sets show that conventional statistical models and their microarray-adapted variants overlook more than 50% of genes showing significant up-regulation. Conjoint PRIM prediction rules recover approximately twice as many differentially expressed transcripts while maintaining strong control over false-positive (Type I) errors. As a result, experimental replication rates increase and total analytic error rates decline. RT-PCR studies confirm that gene inductions detected by PRIM but overlooked by other methods represent true changes in mRNA levels. PRIM-based conjoint inference rules thus represent an improved strategy for high-sensitivity screening of DNA microarrays. AVAILABILITY: Freestanding JAVA application at http://microarray.crump.ucla.edu/focus

Algorithms↗

High fidelity SNP genotyping using sequence-specific primer elongation and fluorescence correlation spectroscopy.

Reliable, efficient and cost-effective modalities are urgently needed for mass screening of gene mutations. Previous reports have shown that SSCP or genechip methods require substantial time and monetary costs, thus limiting their appeal. Sequence Specific Primer Polymerase Chain Reaction (SSP-PCR) is a reliable and cost-effective method that utilizes the 3'-end discrimination properties of polymerase. However, the applicability of conventional SSP-PCR is limited due to the difficulties associated with determining optimal conditions and because mis-matched primers are amplified, resulting in signal noise during end-point assay. To overcome this problem, we eliminated the reverse primers from SSP-PCR, thus preventing amplification of mis-matched primers. We designated this method Sequence-Specific Primer Cycle Elongation (SSPCE). However, the detection of elongated sequence specific primers was difficult using conventional electrophoresis due to the small amounts of amplification product present. We therefore combined SSPCE and Fluorescence Correlation Spectroscopy, which is a novel technique used to determine the number and size of fluorophores at nano-molar concentrations, and designated the method SSPCE-FCS. We compared conventional SSP-PCR and SSPCE-FCS with regard to determining optimal conditions using two Mitochondrial SNPs (G --> A at position 1598, G --> A at position 12192). We were able to determine the optimal conditions for the SNP at position 1598 using either method. However, optimal conditions could only be determined for SSPCE-FCS with the 12192 mutation because non-specific amplification was observed at a wide range of annealing temperatures in SSP-PCR. We then applied this method to three other SNPs and the results were consistent with the results of sequencing data.

Base Sequence↗

Assessing the functional bias of commercial microarrays using the onto-compare database.

Microarrays are at the center of a revolution in biotechnology, allowing researchers to screen tens of thousands of genes simultaneously. Typically, they have been used in exploratory research to help formulate hypotheses. In most cases, this phase is followed by a more focused, hypothesis-driven stage in which certain specific biological processes and pathways are thought to be involved. Since a single biological process can still involve hundreds of genes, microarrays are still the preferred approach as proven by the availability of focused arrays from several manufacturers. Because focused arrays from different manufacturers use different sets of genes, each array will represent any given regulatory pathway to a different extent. We argue that a functional analysis of the arrays available should be the most important criterion used in the array selection. We developed Onto-Compare as a database that can provide this functionality, based on the Gene Ontology Consortium nomenclature. We used this tool to compare several arrays focused on apoptosis, oncogenes, and tumor suppressors. We considered arrays from BD Biosciences Clontech, PerkinElmer, Sigma-Genosys, and SuperArray. We showed that among the oncogene arrays, the PerkinElmer MICROMAX oncogene microarray has a better representation of oncogenesis, protein phosphorylation, and negative control of cell proliferation. The comparison of the apoptosis arrays showed that most apoptosis-related biological processes are equally well represented on the arrays considered. However, functional categories such as immune response, cell-cell signaling, cell-surface receptor linked signal transduction, and interleukins are better represented on the Sigma-Genoys Panorama human apoptosis array. At the same time, processes such as cell cycle control, oncogenesis, and negative control of cell proliferation are better represented on the BD Biosciences Clontech Atlas Select human apoptosis array.

Bias↗

Polymerase chain reaction (PCR) and sequencing.

For sequence analysis of transfected genes there are two approaches which can be adopted. One is to derive a consensus sequence of the gene in question and this may, in addition to providing the basic sequence, provide limited information on the presence of variant sequences. In order to provide more extensive data on variant sequences a second approach has to be adopted and that is to subclone the transfected gene (or mRNA) and analyse the sequences of large numbers of the subclones. While there are few obstacles nowadays to deriving a consensus sequence, considerable care has to be exercised in interpreting sequence data derived after subcloning because of the possible introduction of laboratory artefacts.

Biotechnology↗

[Studies of image quality and dose in digital subtraction angiography].

METHODS: The dose needed for high image quality in l.a. DSA, was determined by investigation of the necessary relationship between dose and image quality. This method is based on measurements of the signal-to-noise ratio and of the contrast-detail detectability. It has been tested on two different systems (Philips integris V3000, Philips Diagnost 97). RESULTS: Our measurements prove that an image intensifier entrance dose of 1.1 microGy (image intensifier diameter 38 cm) is sufficient for high image quality in DSA. An increased dose value does not lead to an improvement in image information. For details larger than the pixel size the 512 matrix produces a higher signal-to-noise ratio with a higher contrast-detail detectability, whereas higher spatial resolution results by the use of a 1024 matrix. In rotational angiography, high image quality can be achieved at an image intensifier entrance dose of 1.1 microGy. In contrast to sequences without rotation, image quality is decreased through movement unsharpness. As the maximum exposure time 25 ms should be selected. The use of a 1024 matrix does not lead to a better spatial resolution in rotational angiography.

Angiography, Digital Subtraction↗

TempliPhi, phi29 DNA polymerase based rolling circle amplification of templates for DNA sequencing.

We have developed a novel, isothermal DNA amplification strategy that employs phi29 DNA polymerase and rolling circle amplification to generate high-quality templates for DNA sequencing reactions. The TempliPhi DNA amplification kits take advantage of the fact that cloned DNA is typically obtained in circular vectors, which are readily replicated in vitro using phi29 DNA polymerase by a rolling circle mechanism. This single subunit, proofreading DNA polymerase has excellent processivity and strand displacement properties for generation of multiple, tandem double-stranded copies of the circular DNA, generating as much as 10(7)-fold amplification. Large amounts of product (1-3 microg) can be obtained in as little as 4 hours. Input DNA can be as little as 0.01 ng of purified plasmid DNA, a single bacterial colony, or a 1 microL of a saturated overnight culture. Additionally, the presence of an associated proof reading function within the phi29 DNA polymerase ensures high-fidelity amplification. Once completed, the product DNA can be used directly in sequencing reactions. Additionally, the properties of phi29 DNA polymerase and its use in applications such as amplification ofhuman genomic DNA for genotyping studies is discussed.

Bacillus Phages↗

Shannon information theoretic computation of synonymous codon usage biases in coding regions of human and mouse genomes.

Exonic GC of human mRNA reference sequences (RefSeqs), as well as A, C, G, and T in codon position 3 are linearly correlated with genomic GC. These observations utilize information from the completed human genome sequence and a large, high-quality set of human and mouse coding sequences, and are in accord with similar determinations published by others. A Shannon Information Theoretic measure of bias in synonymous codon usage was developed. When applied to either human or mouse RefSeqs, this measure is nonlinearly correlated with genomic, exonic, and third codon position A, C, G, and T. Information values between orthologous mouse and human RefSeqs are linearly correlated: mouse = 0.092 + 0.55 human. Mouse genes were consistently placed in genomic regions whose GC content was closer to 50% than was the GC content of the human ortholog. Since the (nonlinear) information versus percent GC curve has a minimum at 50% GC and monotonically increases with increasing distance from 50% GC, this phenomenon directly results in the low slope of 0.55. This appears to be a manifestation of an evolutionary strategy for placement of genes in regions of the genome with a GC content that relates synonymous codon bias and protein folding.

Animals↗

A comprehensive comparison of multiple sequence alignment programs.

In recent years improvements to existing programs and the introduction of new iterative algorithms have changed the state-of-the-art in protein sequence alignment. This paper presents the first systematic study of the most commonly used alignment programs using BAliBASE benchmark alignments as test cases. Even below the 'twilight zone' at 10-20% residue identity, the best programs were capable of correctly aligning on average 47% of the residues. We show that iterative algorithms often offer improved alignment accuracy though at the expense of computation time. A notable exception was the effect of introducing a single divergent sequence into a set of closely related sequences, causing the iteration to diverge away from the best alignment. Global alignment programs generally performed better than local methods, except in the presence of large N/C-terminal extensions and internal insertions. In these cases, a local algorithm was more successful in identifying the most conserved motifs. This study enables us to propose appropriate alignment strategies, depending on the nature of a particular set of sequences. The employment of more than one program based on different alignment techniques should significantly improve the quality of automatic protein sequence alignment methods. The results also indicate guidelines for improvement of alignment algorithms.

Algorithms↗

High quality genome assemblies of African cattle breeds using PacBio HiFi sequencing.

Africa has a uniquely rich cattle diversity of ~150 breeds comprising the Bos taurus indicus sub-species, Bos taurus taurus, and their crosses. These represent ~23% of the global cattle population. However, high quality, representative assemblies are limited for African cattle and especially for indicine breeds. Here we built high quality de novo assemblies for five important African indigenous cattle breeds using PacBio HiFi sequencing: Lagune (Bos taurus taurus), Gudali, Iringa Red and Singida White (Bos taurus indicus), and Mpwapwa (Bos taurus taurus x Bos taurus indicus). These new assemblies are the most contiguous and complete African cattle assemblies produced so far, with genome sizes of 3.25-3.36 Gb, contiguity N50s ranging from 83.59 Mb to 97.87 Mb and scaffold N50s from 100.30 Mb to 113.37 Mb. BUSCO genome completeness scores were also higher than 99.68%, indicative of highly contiguous assemblies. These improved and highly contiguous genome assemblies are consequently a valuable resource for future African and global livestock genomic studies.

Animals↗

[MR-coronary angiography: comparison of SSFP and spoiled GRE sequence (bright blood technique) and a TSE sequence (black blood technique) in healthy volunteers].

PURPOSE: Comparison of a free breathing steady-state free precession (SSFP), a spoiled gradient-echo (GRE) and a turbo spin-echo sequence (TSE) for imaging of the coronary arteries (MRCA) in healthy volunteers. MATERIALS AND METHODS: Twenty-two healthy volunteers were imaged with a standard clinical scanner (1.5 T, Intera, Philips), with the right coronary system imaged in 11 and the left coronary system in the other 11 volunteers. Images were obtained with a 3D-SSFP (balanced TFE, TR 6.2 ms, TE 3.1 ms, alpha 65 degrees ), a 3D-GRE (TFE, TR 7.2 ms, TE 2.2 ms, alpha 30 degrees ) and a 2D-TSE (Dual-IR, TR 2RR, TE 25 ms) sequence. The in plane resolution was 0.7 x 0.8 mm for both the SSFP and GRE sequence with an effective slice thickness of 1.5 mm. For the TSE sequence, an in-plane resolution of 0.7 x 0.9 mm and a slice thickness of 3.0 mm were used. All investigations were performed using prospective navigator gating and slice-following technique. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the blood pool to myocardium and blood pool to epicardial fat were calculated. Image quality and measurement artifacts were assessed for all sequences by 5 independent investigators using a 4- and 5-point grading scale. RESULTS: CNR was significantly higher for the GRE sequence compared with the SSFP sequence and TSE sequence (mean 20.8 +/- 4.8 vs. 14.6 +/- 5.0 and 10.1 +/- 3.7 for blood pool to myocardium; mean 27.5 +/- 6.3 vs. 16.4 +/- 5.4 and 18.1 +/- 5.7 for blood pool to fat). The SNR revealed no significant differences between the SSFP and GRE sequences. The SSFP and the TSE sequences showed significantly more artefacts than the spoiled GRE sequence. Image quality was graded slightly higher for the GRE than for the SSFP sequence for the right coronary system, while there was no substantial difference in the left coronary system (median 2.1 +/- 0.6 and 2.5 +/- 0.6 vs. 2.5 +/- 0.8 and 2.6 +/- 0.7 for the right and left coronary system). In comparison, image quality was lower with the TSE sequence (median 2.9 +/- 0.5 for the right coronary system with p < 0.05 vs. GRE sequence and 3.0 +/- 0.3 for the left coronary system). CONCLUSION: For the scan parameters chosen in this study, the GRE-sequence represents the most robust technique for imaging of the coronary arteries. Currently, the TSE sequence is no alternative.

Adult↗

An application for assessing quality of RNA hybridized to Affymetrix GeneChips.

UNLABELLED: This paper describes a stand-alone application for estimating the 3' to 5' ratio by fitting a mixed effects model to the interior pixel intensities of perfect match probes for selected control probe sets from an Affymetrix *.DAT file. The effectiveness of this method was demonstrated previously by an application of the method to two microarray datasets for which external verification of RNA quality was known. This application provides a more objective assessment of sample quality in that both a point estimate and 95% confidence interval about the 3' to 5' ratio are provided. AVAILABILITY: The software and installation instructions are freely available for download at http://www.people.vcu.edu/~kjarcher/Research/Data.htm

Algorithms↗

Improved substrate specificity of water-soluble pyrroloquinoline quinone glucose dehydrogenase by a peptide ligand.

A new approach in altering the substrate specificity of enzyme is proposed using glucose dehydrogenase, with pyrroroquinoine quinone (PQQGDH) as co-factor, as the model. This approach is based on the selection of random peptide phage displayed library. Using an M13 phage-display random peptide library, we have selected peptide ligands. Among the peptide ligands, a 7-mer peptide, composed of Thr-Thr-Ala-Thr-Glu-Tyr-Ser, caused PQQGDH substrate specificity to decrease significantly toward disaccharides, such as maltose and lactose, while a smaller effect was observed toward glucose. Consequently, this peptide narrowed the substrate specificity of PQQGDH, without a significant loss of the enzyme activity.

Amino Acid Sequence↗

Using multiple interdependency to separate functional from phylogenetic correlations in protein alignments.

MOTIVATION: Multiple sequence alignments of homologous proteins are useful for inferring their phylogenetic history and to reveal functionally important regions in the proteins. Functional constraints may lead to co-variation of two or more amino acids in the sequence, such that a substitution at one site is accompanied by compensatory substitutions at another site. It is not sufficient to find the statistical correlations between sites in the alignment because these may be the result of several undetermined causes. In particular, phylogenetic clustering will lead to many strong correlations. RESULTS: A procedure is developed to detect statistical correlations stemming from functional interaction by removing the strong phylogenetic signal that leads to the correlations of each site with many others in the sequence. Our method relies upon the accuracy of the alignment but it does not require any assumptions about the phylogeny or the substitution process. The effectiveness of the method was verified using computer simulations and then applied to predict functional interactions between amino acids in the Pfam database of alignments.

Algorithms↗

Non-linear normalization and background correction in one-channel cDNA microarray studies.

MOTIVATION: Data from one-channel cDNA microarray studies may exhibit poor reproducibility due to spatial heterogeneity, non-linear array-to-array variation and problems in correcting for background. Uncorrected, these phenomena can give rise to misleading conclusions. RESULTS: Spatial heterogeneity may be corrected using two-dimensional loess smoothing (Colantuoni et al., 2002). Non-linear between-array variation may be corrected using an iterative application of one-dimensional loess smoothing. A method for background correction using a smoothing function rather than simple subtraction is described. These techniques promote within-array spatial uniformity and between-array reproducibility. Their application is illustrated using data from a study of the effects of an insulin sensitizer, rosiglitazone, on gene expression in white adipose tissue in diabetic db/db mice. They may also be useful with data from two-channel cDNA microarrays and from oligonucleotide arrays. AVAILABILITY: R functions for the methods described are available on request from the author.

Adipose Tissue↗

A study of inter-lab and inter-platform agreement of DNA microarray data.

As gene expression profile data from DNA microarrays accumulate rapidly, there is a natural need to compare data across labs and platforms. Comparisons of microarray data can be quite challenging due to data complexity and variability. Different labs may adopt different technology platforms. One may ask about the degree of agreement we can expect from different labs and different platforms. To address this question, we conducted a study of inter-lab and inter-platform agreement of microarray data across three platforms and three labs. The statistical measures of consistency and agreement used in this paper are the Pearson correlation, intraclass correlation, kappa coefficients, and a measure of intra-transcript correlation. The three platforms used in the present paper were Affymetrix GeneChip, custom cDNA arrays, and custom oligo arrays. Using the within-platform variability as a benchmark, we found that these technology platforms exhibited an acceptable level of agreement, but the agreement between two technologies within the same lab was greater than that between two labs using the same technology. The consistency of replicates in each experiment varies from lab to lab. When there is high consistency among replicates, different technologies show good agreement within and across labs using the same RNA samples. On the other hand, the lab effect, especially when confounded with the RNA sample effect, plays a bigger role than the platform effect on data agreement.

Animals↗

Modeling three-dimensional protein structures for amino acid sequences of the CASP3 experiment using sequence-derived predictions.

Homology or comparative modeling is aimed at modeling the three-dimensional structure of a target sequence of unknown structure using the framework of an already known fold. Traditionally, homology modeling has been applied to targets with clear sequence similarity to proteins of known structure. Because methods to identify increasingly distant relationships have been developed, homology models can now be built for a wider range of targets. The first challenge in homology modeling is to obtain an initial, accurate, sequence-structure alignment with the most compatible fold. In CASP3, the abilities of fold-recognition methods to fulfill this challenge were evaluated with a number of target sequences of unknown structure. Sequence-structure alignments for 33 of the CASP3 targets using the fold-recognition method SDP were submitted (Fischer and Eisenberg, Protein Sci 1996; 5:947-955). After the three-dimensional structures of the sequences were subsequently released, the quality of the predictions were evaluated. Here I describe three of the predictions for targets with little sequence similarity to proteins of known structure that were judged by the assessors to be of higher quality. For two of these predictions, the sequence-structure alignment corresponded perfectly to the structural alignment (zero average shift), and for the third, the average shift was 0.1. This alignment accuracy entails an ideal starting point for homology modeling.

Amino Acid Sequence↗

Broadband heteronuclear Hartmann-Hahn sequences with short cycle times.

For some applications, broadband heteronuclear Hartmann-Hahn sequences with very short cycle times are required. A quality factor is presented that makes it possible to assess the relative sizes of cycle time, bandwidth, and maximum RF amplitude for any given multiple-pulse sequence. This quality factor is determined for multiple-pulse sequences that are commonly used in HEHAHA experiments and for some favorable sequences that were so far only discussed in the context of heteronuclear decoupling.

Magnetic Resonance Spectroscopy↗