Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SPACE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

[Does the subdural space exist?].

A potential space between the dura mater and the arachnoides is thought to exist, occupied by a serous fluid and called the subdural space. Recent studies may change this classical concept, however. The dura-arachnoid complex from the epidural to the arachnoid space is formed by morphologically distinct layers: the dura mater, the subdural compartment and the arachnoid mater, which are made up of different cell types. The dura mater consists of greater and lesser laminae formed mainly of collagen fibers aligned differently. The subdural compartment is formed by a number of so-called "neurothelial cells", which are in close contact with the inner dural layers. These cells are flat and have long interlaced branches. The arachnoides are made of cells grouped in three different layers. The outer layer is the "barrier arachnoid layer". Located just inside the anterior cell plane, this layer is made of less flattened cells that form an epithelial-type tissue, with complex cell-cell junctures surrounded by collagen fibers. The middle layer is the reticular arachnoid, composed of irregularly interlaced cells alternating with collagen fibers and intercellular gaps of varying sizes. The innermost layer, the trabecular arachnoid, is in direct contact with the subarachnoid space. The cells of this layer form strands that contribute to the weblike pattern found in the subarachnoid space. Recently, special techniques for fixing and preparing samples, preserving in situ the anatomical relations between the arachnoides and the dura mater, have allowed us to examine the normal configuration of the subdural space. All samples examined revealed the presence of a cellular plane between the dura mater and the arachnoides, with no evidence of the classically described space. The zone of least resistance in the dura-arachnoid complex was the subdural compartment, which could be torn mainly along intercellular spaces, though cell rupture was also observed, affecting the cytoplasmic membranes of adjacent cells. The subdural space is opened by tearing the subdural compartment between neurothelial cells alongside the collagen fibers of the dura mater. Such a tear can be caused mechanically by injecting air or contrast media, which exert pressure on a laminar structure that tends to separate because it is weaker than neighboring ones.

Animals↗

NASA's Space Life Sciences Training Program.

The Space Life Sciences Training Program (SLSTP) is an intensive, six-week training program held every summer since 1985 at the Kennedy Space Center (KSC). A major goal of the SLSTP is to develop a cadre of qualified scientists and engineers to support future space life sciences and engineering challenges. Hand-picked, undergraduate college students participate in lectures, laboratory sessions, facility tours, and special projects: including work on actual Space Shuttle flight experiments and baseline data collection. At NASA Headquarters (HQ), the SLSTP is jointly sponsored by the Life Sciences Division and the Office of Equal Opportunity Programs: it has been very successful in attracting minority students and women to the fields of space science and engineering. In honor of the International Space Year (ISY), 17 international students participated in this summer's program. An SLSTP Symposium was held in Washington D.C., just prior to the World Space Congress. The Symposium attracted over 150 SLSTP graduates for a day of scientific discussions and briefings concerning educational and employment opportunities within NASA and the aerospace community. Future plans for the SLSTP include expansion to the Johnson Space Center in 1995.

Biological Science Disciplines↗

Physiology, medicine, long-duration space flight and the NSBRI.

The hazards of long-duration space flight are real and unacceptable. In order for humans to participate effectively in long-duration orbital missions or continue the exploration of space, we must first secure the health of the astronaut and the success of such missions by assessing in detail the biomedical risks of space flight and developing countermeasures to these hazards. Acquiring the understanding necessary for building a sound foundation for countermeasure development requires an integrated approach to research in physiology and medicine and a level of cooperative action uncommon in the biomedical sciences. The research program of the National Space Biomedical Research Institute (NSBRI) was designed to accomplish just such an integrated research goal, ameliorating or eliminating the biomedical risks of long-duration space flight and enabling safe and productive exploration of space. The fruits of these labors are not limited to the space program. We can also use the gained understanding of the effects and mechanisms of the physiological changes engendered in space and the applied preventive and rehabilitative methods developed to combat these changes to the benefit of those on Earth who are facing similar physiological and psychological difficulties. This paper will discuss the innovative approach the NSBRI has taken to integrated research management and will present some of the successes of this approach.

Academies and Institutes↗

Ensuring of long operation life of the orbiting station EVA space suit.

Russia has gained a lot of experience in operating the space suits (SS) during the extravehicular activities (EVA) by the crews of SALYUT-6, SALYUT-7 and MIR orbiting stations. A total of 21 Orlan-type space suits of various models were operated onboard the orbiting stations (OS) during almost 20 years period. Some of these space suits served up to 3 years in orbit. The paper reviews special features of long SS operation (without return to the Earth) onboard an orbiting station as well as the problems associated with SS repeated use by several crews. An analysis of measures to support solving of the problems of SS long stay and reliable operation onboard the orbiting station is made: selection of a corresponding SS type and separate elements design; selection of the materials; routine and preventive maintenance; development tests. The advantages of the space suit of a semi-rigid type for solving the above problems are shown. The paper includes a short analysis of space suits' operation onboard the Russian orbiting station MIR, and some restuts of inspection of the Orlan-DMA space suit returned to the Earth from orbit by STS-79 alter long operation in orbit. Recommendations on further improvement of the space suits for EVA operations in the International Space Station (ISS) are given.

Decompression Sickness↗

Dose measurements in space by the Hungarian Pille TLD system.

Exposure of crew, equipment, and experiments to the ambient space radiation environment in low Earth orbit poses one of the most significant problems to long-term space habitation. Accurate dose measurement has become increasingly important during the assembly (extravehicular activity (EVA)) and operation of space stations such as on Space Station Mir. Passive integrating detector systems such as thermoluminescent dosemeters (TLDs) are commonly used for dosimetry mapping and personal dosimetry on space vehicles. The well-known advantages of passive detector systems are their independence of power supply, small dimensions, high sensitivity, good stability, wide measuring range, resistance to environmental effects, and relatively low cost. Nevertheless, they have the general disadvantage that for evaluation purposes they need a laboratory or large--in mass and power consumption--terrestrial equipment, and consequently they cannot provide time-resolved dose data during long-term space flights. KFKI Atomic Energy Research Institute (KFKI AEKI) has developed and manufactured a series of thermoluminescent dosemeter systems for measuring cosmic radiation doses in the 10 microGy to 10 Gy range, consisting of a set of bulb dosemeters and a compact, self-contained, TLD reader suitable for on-board evaluation of the dosemeters. By means of such a system, highly accurate measurements were carried out on board the Salyut-6, -7 and Mir Space Stations as well as on the Space Shuttle. A detailed description of the system is given and the comprehensive results of these measurements are summarised.

Astronauts↗

Space Station Biological Research Project.

To meet NASA's objective of using the unique aspects of the space environment to expand fundamental knowledge in the biological sciences, the Space Station Biological Research Project at Ames Research Center is developing, or providing oversight, for two major suites of hardware which will be installed on the International Space Station (ISS). The first, the Gravitational Biology Facility, consists of Habitats to support plants, rodents, cells, aquatic specimens, avian and reptilian eggs, and insects and the Habitat Holding Rack in which to house them at microgravity; the second, the Centrifuge Facility, consists of a 2.5 m diameter centrifuge that will provide acceleration levels between 0.01 g and 2.0 g and a Life Sciences Glovebox. These two facilities will support the conduct of experiments to: 1) investigate the effect of microgravity on living systems; 2) what level of gravity is required to maintain normal form and function, and 3) study the use of artificial gravity as a countermeasure to the deleterious effects of microgravity observed in the crew. Upon completion, the ISS will have three complementary laboratory modules provided by NASA, the European Space Agency and the Japanese space agency, NASDA. Use of all facilities in each of the modules will be available to investigators from participating space agencies. With the advent of the ISS, space-based gravitational biology research will transition from 10-16 day short-duration Space Shuttle flights to 90-day-or-longer ISS increments.

Aerospace Medicine↗

Life sciences issues affecting space exploration.

The U.S. space program is undertaking a serious examination of new initiatives in human space exploration involving permanent colonies on the Moon and an outpost on Mars. Life scientists have major responsibilities to the crew, to assure their health, productivity, and safety throughout the mission and the postflight rehabilitation period; to the mission, to provide a productive working environment; and to the scientific community, to advance knowledge and understanding of human adaptation to the space environment. Critical areas essential to the support of human exploration include protection from the radiation hazards of the space environment, reduced gravity countermeasures, artificial gravity, medical care, life support systems, and behavior, performance, and human factors in an extraterrestrial environment. Developing solutions to these concerns is at the heart of the NASA Life Sciences ground-based and flight research programs. Facilities analogous to planetary outposts are being considered in Antarctica and other remote settings. Closed ecological life support systems will be tested on Earth and Space Station. For short-duration simulations and tests, the Space Shuttle and Spacelab will be used. Space Station Freedom will provide the essential scientific and technological research in areas that require long exposures to reduced gravity conditions. In preparation for Mars missions, research on the Moon will be vital. As the challenges of sustaining humans on space are resolved, advances in fundamental science, medicine and technology will follow.

Adaptation, Physiological↗

The International Space Life Sciences Working Group.

The International Space Life Sciences Working Group (ISLSWG) is made up of representatives from five space agencies: the National Aeronautics and Space Administration (NASA), the European Space Agency (ESA), the Canadian Space Agency (CSA), the Centre National d'Etudes Spatiale (CNES), the Deutsches Zentrum fur Luft- und Raumfahrt (DLR, formerly the Deutsche Agentur fur Raumfahrtangelegenheiten or DARA), and the National Space Development Agency of Japan (NASDA). The group met for the first time in 1989, and since that time has developed a Strategic Plan and has taken concrete steps to implement this plan. The result is a closely coordinated international program of Space Life Sciences which will enable optimal utilization of space flight opportunities.

Biological Science Disciplines↗

Diagnostic accuracy of a bedside D-dimer assay and alveolar dead-space measurement for rapid exclusion of pulmonary embolism: a multicenter study.

CONTEXT: A previous study suggested that the combination of a normal D-dimer assay and normal alveolar dead-space fraction is a highly sensitive screening test for pulmonary embolism (PE). OBJECTIVE: To determine if the combination of a normal alveolar dead-space fraction (volume of alveolar dead space/tidal volume </=20%) and a normal whole-blood agglutination D-dimer assay can exclude PE in emergency department (ED) patients. DESIGN: Prospective, noninterventional study conducted in 1998-1999. Study data were obtained prior to standard testing for PE, consisting of radionuclide lung scanning or contrast-enhanced computed tomography and 6-month follow-up plus selective use of venous ultrasonography and pulmonary angiography. Imaging studies were interpreted by blinded observers. SETTING: Six urban teaching hospitals in the United States. PATIENTS: A total of 380 hemodynamically stable ED patients aged 18 years or older with suspected acute PE. MAIN OUTCOME MEASURES: Sensitivity and specificity for PE with a positive test defined as having either alveolar dead-space fraction or D-dimer assay results abnormal. Alveolar dead-space fraction was determined by subtracting airway dead space from physiological dead space (determined using the modified Bohr equation) and D-dimer assay, assayed at bedside using 20 microL of arterial blood. RESULTS: Pulmonary embolism was diagnosed in 64 patients (16.8%), of those 20 had an abnormal D-dimer assay result, 3 had an abnormal alveolar dead-space fraction, 40 had abnormal results in both, and 1 had normal results for both tests. The sensitivity for diagnosis of PE was 98.4% (95% confidence interval [CI], 91.6%-100.0%). Among the 316 patients without PE, both D-dimer and dead-space results were normal in 163, for a specificity of 51.6% (95% CI, 46.1%-57.1%). Posterior probability of PE with normal results on both tests was 0.75% (95% CI, 0%-3.4%). CONCLUSION: In this multicenter study of ED patients, a normal D-dimer assay result plus a normal alveolar dead-space fraction was associated with a low prevalence of PE.

Adult↗

Small fiber diameter fibro-porous meshes: tissue response sensitivity to fiber spacing.

The purpose of this research was to determine if fiber spacing for small fiber diameter fibro-porous meshes affected tissue response in vivo. Disk-shaped polyurethane meshes, with mean fiber diameters of 7.6 microm and fiber spacing between 6 and 68 microm, were implanted in rat subcutaneous dorsum for 5-week intervals and then prepared for light microscopy and morphological analysis. Results showed that implants with 12- to 68-microm spacing had no histologically apparent fibrous capsule around the perimeter, a result different from that for 6-microm spacing samples that had a capsule around a mean of 34.2% of the perimeter. For the 12- to 68-microm spacing range, a mean of 21.0% of individual fibers within the meshes were encapsulated. Qualitatively, it appeared that larger fibers were encapsulated more frequently than smaller ones. When nodeless or baggy meshes were implanted, cells tended to cluster three or more fibers into groups and then encapsulate each group. Over the 6- to 68-microm spacing range, cell nuclei volume fraction within the meshes increased from the 6- to the 29-microm spacing (p = 0.000) and then decreased from the 29- to the 68-microm spacing (p = 0.015). There was a trend of an increase in local vessel volume fraction with spacing over the 6- to 68-microm range, though the relationship was weak. The results indicate that the reason for the lack of encapsulation of small-fiber fibro-porous meshes is not exclusively a pore boundary explanation, as is proposed for small-pore porous meshes.

Biocompatible Materials↗

Dynamic k-space filling for bolus chase 3D MR digital subtraction angiography.

A bolus chase three-dimensional (3D) MR digital subtraction angiography (MRDSA) technique was implemented using dynamic k-space filling. This technique permits rapid 3D arterial imaging of the entire lower extremity at multiple stations using a single intravenous injection. Image acquisition at the first (most proximal) station starts from the edge of k-space and ends in the center of k-space (edge-center order). Image acquisition for middle stations starts from the edge of k-space, arrives at the center of k-space at the middle of data acquisition, and ends at the edge of k-space (edge-center-edge order). Image acquisition for the last station starts from the center of k-space and ends at the edge of k-space (center-edge order). This dynamic k-space filling minimizes contrast dose and motion artifacts. Bolus chase 3D MRDSA was performed on four normal volunteers and three patients using a multiple-phase 3D fast gradient-echo sequence, 25-ml gadolinium dose, and a prototype stepping table. Total bolus chase 3D acquisition time was 46 s. Mask subtraction using both complex and magnitude subtraction was performed. Complex subtraction was found to be necessary for proper delineation of arteries below the aortic bifurcation. Diagnostic results were consistently obtained for all subjects.

Adult↗

Deriving shape space parameters from immunological data.

We present a method for deriving shape space parameters that are consistent with immunological data, and illustrate the method by deriving shape space parameters for a model of cross-reactive memory. Cross-reactive memory responses occur when the immune system is primed by one strain of a pathogen and challenged with a related, but different, strain. Much of the nature of a cross-reactive response is determined by the quantity and distribution of the memory cells, raised to the primary antigen, that cross-react with the secondary antigen. B cells with above threshold affinity for an antigen lie in a region of shape space that we call a ball of stimulation. In a cross-reactive response, the intersection of the balls of stimulation of the primary and secondary antigens contains the cross-reactive B cells and thus determines the degree of cross-reactivity between the antigens. We derive formulas for the volume of intersection of balls of stimulation in different shape spaces and show that the parameters of shape space, such as its dimensionality, have a large impact on the number of B cells in the intersection. The application of our method for driving shape space parameters indicates that, for Hamming shape spaces, 20 to 25 dimensions, a three or four letter alphabet, and balls of stimulation of radius five or six, are choices that match the experimental data. For Euclidean shape spaces, five to eight dimensions and balls of stimulation with radius about 20% of the radius of the whole space, match the experimental data.

Antigens↗

Ocular exploration of space as a function of neck proprioceptive and vestibular input--observations in normal subjects and patients with spatial neglect after parietal lesions.

We recently argued that the specific compensation of spatial neglect by manipulating neck proprioceptive and vestibular input is due to a central "correction" of the disturbed neural transformation process converting the afferent input coordinates from the peripheral sensory organs into a central representation of egocentric space. Both types of stimulation were proposed to induce a reorientation of the deviated or distorted egocentric spatial reference frame. The aim of the present study was to observe this process of reorientation under a condition in which no visual stimulus can attract the subject's attention and thus influence exploration behaviour from outside. We recorded eye movements of normal subjects and of three patients with spatial neglect after right parietal lesions while searching for a non-existent target in complete darkness. It was assumed that the area of the outer space that subjects spontaneously explore under this condition is a direct function of the subject's representation of egocentric space. Ocular space exploration was biased and confined almost entirely to the right side of the midsagittal plane in patients with neglect. This spatial distribution of exploratory eye movements changed remarkably with left-sided neck muscle vibration as well as with left-sided vestibular stimulation using ice water calorics. The spatial area of exploration was significantly enlarged to the contralesional side and the exploration maximum shifted in the same direction. Whereas with both types of stimulation space exploration of patients with neglect was similar to that of normal subjects when not being stimulated, neck proprioceptive and vestibular stimulation in normal subjects induced a quasi neglect-like exploration pattern, i.e. a bias to one side of the objective midsagittal plane. If ocular space exploration was, however, related to the subjectively perceived position of the midsagittal plane in space, eye movements were symmetrically distributed and carried out to both sides of subjective "straight ahead" in all experimental conditions, in normal subjects as well as in patients with neglect. The present results support the above hypothesis and indicate that neck proprioceptive as well as vestibular input directly contribute to the computation of the subject's central representation of egocentric space used for localizing body orientation and for guiding motor behaviour in space.

Adult↗

Anatomic bases for anterior spinal surgery: surgical anatomy of the cervical vertebral body and disc space.

Twenty adult cadaveric cervical spines were sectioned longitudinally through the midline to display longitudinal sections of the vertebral bodies and disc spaces from C3 to T1. Computer-assisted anatomic images were obtained for measurements of the disc spaces and vertebral bodies. Anteroposterior (AP) depth gradually increased from 16.56 +/- 2.21 mm at C3 to 19.32 +/- 2.30 mm at C7. Greater values of AP depth at the inferior endplate were found at C5 (20.75 +/- 2.87 mm) and C6 (20.56 +/- 2.31 mm) compared with the values at C3 (18.26 +/- 1.82 mm), C4 (19.27 +/- 2.88 mm) and C7 (19.21 +/- 3.22 mm). The AP depth at the superior endplate was greater than that at the inferior endplate. The height of the disc space was found to be lowest at the posterior disc space from C2-3 to C7-T1 (2.95 +/- 0.86 mm at C2-3, 2.78 +/- 0.93 mm at C3-4, 2.45 +/- 0.79 mm at C4-5, 2.92 +/- 0.64 mm at C5-6, 2.46 +/- 0.59 mm at C6-7, 2.93 +/- 1.05 mm at C7-T1), when compared to the height of the disc space at the anterior disc space from C2-3 to C7-T1 (4.07 +/- 0.85 mm at C2-3, 4.34 +/- 1.18 mm at C3-4, 3.95 +/- 1.37 mm at C4-5, 3.55 +/- 1.37 mm at C5-6, 3.55 +/- 0.76 mm at C6-7, 3.67 +/- 1.17 mm at C7-T1). The mid-axis of the disc space was situated at approximately 3 mm above the anterior midpoint of the annulus fibrosus at the level of the lower cervical spine. To reach the posterior portion of the disc space from the anterior midpoint of the annulus fibrosus, a 5 degrees cephalad angulation of the drill relative to the mid-axis of the disc space is necessary. All these original data from cadavers may be helpful during anterior approach for discectomy, vertebrectomy and anterior screw-plate placement.

Aged↗

The clinoidal space: anatomical review and surgical implications.

This study describes the anatomy of the clinoidal space exposed after the anterior clinoid process (ACP) is removed. Five cadaver heads injected with colored latex in the arterial and venous systems were used. Each was cut in half to provide ten specimens for inspection. The bone that covered the medial side of the cavernous and clinoidal internal carotid artery (ICA) was removed. The ACP was removed and its dural layers were preserved. The removal of the ACP establishes an area called the clinoidal space. In this space, the clinoidal ICA is exposed. This space is delimited by two dural rings that anchors the clinoidal ICA. Most of the clinoidal space is located anterolateral to the artery where the ACP is found, but there is a small triangular space posterior to the artery and another space anteromedial to it. The clinoidal ICA is completely encased by connective tissue in this space. The clinoidal space is extracavernous, therefore, bleeding occurs only if the connective tissue layer is broken.

Cadaver↗

The pre-styloid compartment of the parapharyngeal space: a three-dimensional digitized model based on the Chinese Visible Human.

To build a digitized visible model of the parapharyngeal space of the Chinese Visible Human and to provide a sectional anatomic basis for radiological and clinical diagnosis of the parapharyngeal space, sectional anatomy data of the parapharyngeal space were selected from the Chinese Visible Human male and female to compare with MR imaging findings in the axial planes. From these data the parapharyngeal space and surrounding structures were segmented. They were then reconstructed in three dimensions on PC. In the axial planes of the sectional anatomy and MR imaging, the shape, content and relations of the parapharyngeal space were clearly displayed and the dominant plane for showing the parapharyngeal space was elicited. The three-dimensional reconstructed images displayed perfectly the anatomic relationships of the parapharyngeal space, parotid, muscles, mandible and vessels. All reconstructed structures can be displayed singly, in groups or as a whole; any diameter or angle of the reconstructed structures can be easily measured. The Chinese Visible Human male and female data set can provide complete and accurate data. The digitized model of the parapharyngeal space and its surroundings offers unique insights into the complex anatomy of the area, providing morphologic data for imaging diagnosis and surgery of the parapharyngeal space.

Anatomy, Cross-Sectional↗

In vivo serial joint space measurements during dynamic loading in a canine model of osteoarthritis.

OBJECTIVE: To devise a reliable, sensitive method to measure joint space in vivo during dynamic loading. Additionally, to determine if dynamic joint space changes were related to the severity of long-term cartilage damage. DESIGN: Subjects were 23 adult foxhounds (18 experimental, 5 control). Experimental subjects had surgically transected cranial cruciate ligaments (CCL). Dynamic joint space was serially measured in vivo over 2 years using a unique high speed stereo radiographic system in combination with subject-specific computed tomography reconstructions. RESULTS: Dynamic joint space was measured in vivo with a within-day precision of 0.09 mm. Half of the experimental subjects developed minor articular cartilage damage and the other half developed severe articular cartilage damage in the medial knee compartment. Joint space during treadmill running increased significantly in the minor damage group in both the medial (+0.61 mm, P = 0.036) and lateral (+0.84 mm, P = 0.002) compartments of the knee. Dynamic joint space in the severe damage group did not increase significantly on either the medial (+0.27 mm, P = 0.408) or lateral (+0.44 mm, P = 0.199) side. The majority of the change in joint space occurred the first year after CCL transection. Medial meniscus damage was related to severity of medial articular cartilage damage (tau = 0.447, P = 0.003). The minor damage group developed 73% of all osteophytes noted at dissection. CONCLUSIONS: This technique is a precise tool for measuring joint space serially in vivo under dynamic loading conditions. The data suggest decreased severity in long-term articular cartilage damage is related to: osteophyte formation, less severe medial meniscus damage and increased joint space the first 12 months after injury.

Animals↗

The Talairach coordinate of a point in the MNI space: how to interpret it.

To perform group studies using functional imaging data, the individual brain images are usually transformed into a common coordinate space. The two most widely used spaces in the neuroscience community are the Talairach space and the Montreal Neurological Institute (MNI) space. The Talairach coordinate system has become the standard reference for reporting the brain locations in scientific publication, even when the data have been spatially transformed into different brain templates (e.g., MNI space). When expressed in terms of individual subjects, the mapping of a coordinate in MNI space to the Talairach space generates distinct coordinates for different subjects. In this paper, we describe two approaches to derive the Talairach coordinates from the MNI space, which is based on the ICBM152 template from the International Consortium of Brain Mapping. One approach is the Talairach Method of Piecewise Linear Scaling (TMPLS) as implemented in the AFNI software package; and the other is a template-matching approach using the linear transformation in SPM99. The uncertainty measurements of the mapping results are presented. This may allow researchers to better interpret results reporting in the Talairach coordinates obtained from the MNI space. This study also examines the discrepancy between the derived Talairach coordinates and those obtained from the mni2tal script, a tool commonly used by the neuroimaging community. Large discrepancies are found in the inferior regions, superior frontal and occipital regions.

Adult↗