Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Refractometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Coupled plasmon-waveguide resonators: a new spectroscopic tool for probing proteolipid film structure and properties.

A variant of surface plasmon resonance (SPR) spectroscopy has been developed that involves a coupling of plasmon resonances in a thin metal film and waveguide modes in a dielectric overcoating. This new technique is referred to as coupled plasmon-waveguide resonance (CPWR) spectroscopy. It combines a greatly enhanced sensitivity (due to increased electromagnetic field intensities at the dielectric surface) and spectral resolution (due to decreased resonance linewidths), with the ability to directly measure anisotropies in refractive index and optical absorption coefficient in a dielectric film adsorbed onto the surface of the overcoating. Experimental data obtained with an egg phosphatidylcholine bilayer are presented to document these properties.

Anisotropy↗

Mapping fluorophore distributions in three dimensions by quantitative multiple angle-total internal reflection fluorescence microscopy.

The decay of evanescent field intensity beyond a dielectric interface depends upon beam incident angle, enabling the 3-d distribution of fluorophores to be deduced from total internal reflection fluorescence microscopy (TIRFM) images obtained at multiple incident angles. Instrumentation was constructed for computer-automated multiple angle-TIRFM (MA-TIRFM) using a right angle F2 glass prism (n(r) 1.632) to create the dielectric interface. A laser beam (488 nm) was attenuated by an acoustooptic modulator and directed onto a specified spot on the prism surface. Beam incident angle was set using three microstepper motors controlling two rotatable mirrors and a rotatable optical flat. TIRFM images were acquired by a cooled CCD camera in approximately 0.5 degree steps for >15 incident angles starting from the critical angle. For cell studies, cells were grown directly on the glass prisms (without refractive index-matching fluid) and positioned in the optical path. Images of the samples were acquired at multiple angles, and corrected for angle-dependent evanescent field intensity using "reference" images acquired with a fluorophore solution replacing the sample. A theory was developed to compute fluorophore z-distribution by inverse Laplace transform of angle-resolved intensity functions. The theory included analysis of multiple layers of different refractive index for cell studies, and the anisotropic emission from fluorophores near a dielectric interface. Instrument performance was validated by mapping the thickness of a film of dihexyloxacarbocyanine in DMSO/water (n(r) 1.463) between the F2 glass prism and a plano-convex silica lens (458 mm radius, n(r) 1.463); the MA-TIRFM map accurately reproduced the lens spherical surface. MA-TIRFM was used to compare with nanometer z-resolution the geometry of cell-substrate contact for BCECF-labeled 3T3 fibroblasts versus MDCK epithelial cells. These studies establish MA-TIRFM for measurement of submicroscopic distances between fluorescent probes and cell membranes.

3T3 Cells↗

Refractive indices of the collagen fibrils and extrafibrillar material of the corneal stroma.

Ultrastructural data from x-ray diffraction studies of the cornea were used to estimate the refractive indices of the collagen fibrils and extrafibrillar material of human, ox, trout, and rabbit corneas. X-ray diffraction measurements of the size and spacing of the collagen fibrils and the separation between the constituent molecules of the fibrils were taken from a previous species study. The tissue volume fractions occupied by the stromal components were estimated and their refractive indices were calculated using the Gladstone-Dale law of mixtures. For the fibrils and extrafibrillar material, the refractive indices in the human cornea were 1.411 and 1.365; for the ox 1.413 and 1.357; for the rabbit 1.416 and 1.357; and for the trout 1.418 and 1.364, respectively. An alternative estimate based on the physical properties and chemical composition of bovine cornea, accounting for interfibrillar type VI collagen and cellular water, produced similar estimates of 1.416 and 1.356 for the fibrils and extrafibrillar material, respectively.

Animals↗

Separation and quantification of alkylphosphocholines by reversed phase high performance liquid chromatography.

Alkylphosphocholines represent a new class of drugs with remarkable antineoplastic and antiprotozoal activity. For instance, hexadecylphosphocholine has been approved for the topical treatment of skin metastasis. In addition, it was successfully studied in India for the treatment of leishmaniasis. Different phase-I and phase-II-trials resulted in cure rates of more than 97%. To optimize antitumor or antiprotozoal activity, we have prepared alkylphosphocholines differing in chain length and unsaturation. For the qualitative and quantitative analysis of these longer chain analogues, we have used isocratic high performance liquid chromatography. The separation of the alkylphosphocholines with different chain lengths in this reversed phase HPLC system was achieved on a YMC-TMS column with a mobile phase consisting of methanol-water (85:15; v/v) at a flow rate of 1.0 ml/min. Furthermore the cis-/trans-isomers such as oleylphosphocholine and elaidylphosphocholine were clearly separated on a YMC-C8 column with a methanol-water mixture (80:20; v/v) as mobile phase. In the described reversed phase HPLC systems simple refractive index detection and UV detection allow the sensitive and quantitative determination of alkylphosphocholines. These methods are very important for reproducible identification and quantitative determination of saturated and mono-unsaturated alkylphosphocholines with alkyl residues containing up to 25 carbon atoms.

Chromatography, High Pressure Liquid↗

Determination of alpha-amylase using 4-O-beta-D-galactopyranosylmaltotetraose (Gal-G4) as a substrate.

A new substrate, 4-O-beta-D-galactopyranosylmaltotetraose (Gal-G4) is applied for the determination of alpha-amylase in serum and urine in a coupled assay with alpha-glucosidase (EC 3.2.1.20), glucokinase (EC 2.7.1.2) and glucose-6-phosphate dehydrogenase (EC 1.1.1.49) as auxiliary enzymes. Gal-G4 having a 4-position of the non-reducing-end glucose residue modified by a beta-galactopyranose group is resistant for degradation by alpha-glucosidase as auxiliary enzyme. Moreover, this substrate is hydrolyzed at just one position by alpha-amylase in serum and urine. More than 99% of the products generated from Gal-G4 by alpha-amylase are identified 4-O-beta-D-galactopyranosylmaltose (Gal-G2), maltose, respectively. Glucose and maltose do not interfere the value of alpha-amylase activity at least up to 0.056 mmol/l (1 g/dl) glucose and 0.027 mmol/l (1 g/dl) maltose, respectively. We are now carrying out this work under the authority of The Enzyme committee of Japanese Society of Clinical Chemistry (JSCC) as a standard method for determination of alpha-amylase in clinical chemistry.

Carbohydrate Conformation↗

Correlation between changes in morphology, electrical properties, and angiotensin-converting enzyme activity in the failing heart.

Evidence is available that morphologic and electrophysiologic abnormalities are present in the failing heart. In the present work, the progressive changes in electrical properties and morphology of the failing heart of Syrian cardiomyopathic hamsters (TO2) were investigated at different stages of the pathological process, and the possible role of the renin-angiotensin system was studied. Cardiomyopathic hamsters 2 and 11 months of age were used. Age-matched normal hamsters (F1B) were utilized as controls. Measurements of membrane potential, conduction velocity and refractoriness were made with conventional intracellular electrodes connected to a high impedance DC amplifier. Serum and cardiac angiotensin-converting enzyme (ACE) activities were measured in controls and cardiomyopathic animals. The results indicated that interstitial fibrosis and calcification were present in the heart of 2-month old Syrian cardiomyopathic hamsters. Measurements of the resting potential performed in the isolated right ventricle of 2-month old Syrian cardiomyopathic hamsters indicated an average value of -66.7 +/- 0.96 mV (n = 25); in the controls of the same age was -78.5 +/- 1 mV (n = 25, P < 0.05); and in 11-month old cardiomyopathic hamsters was -67.8 +/- 0.83 mV (n = 10). The duration of the action potential measured at 50 and 90% of repolarization in 2-month old hamsters was well above the controls. The conduction velocity measured in the isolated right ventricle of 2-month old Syrian cardiomyopathic hamsters (44.2 +/- 1.6 cm/s, n = 12) was not different from the control (43.7 +/- 1.1 cm/s, n = 7, P > 0.05) but was significantly larger than that recorded from the ventricle of 11-month old animals (37.8 +/- 2.9 cm/s, n = 11, P < 0.05). ACE activity was 0.26 +/- 0.01 nmol/mg x min in the heart of controls at 2 months of age and did not change with age. Although in the 2-month old cardiomyopathic hamsters the enzyme activity (0.28 +/- 0.04 nmol/mg x min) was not different from the controls (P > 0.05), in myopathic animals at 11 months of age, the enzyme activity (0.56 +/- 0.027 nmol/mg x min) was greater than controls (P < 0.05). The ACE activity in plasma followed the same pattern. The conclusion from these experiments is, that some parameters like resting potential, action potential duration, and morphological abnormalities appeared quite early in the failing process. The decline in conduction velocity, however, appeared later on, concurrently with the activation of plasma and cardiac renin-angiotensin systems.

Age Factors↗

Colloid osmotic pressure of steer crystallins: implications for the origin of the refractive index gradient and transparency of the lens.

The osmotic behavior of soluble cortical and nuclear steer lens crystallins was characterized by secondary osmometry for several ionic strength and pH conditions. Osmotic pressure versus protein concentration relationships were measured for pressures up to 1.15 x 10(6) dyn cm-2. At low concentrations (< 0.2 g ml-1), the osmotic pressure increased linearly with pressure, whereas for concentrations above 0.2 g ml-1, the pressure rose more sharply, giving progressively larger changes in osmotic pressure with increasing crystallin concentration. At a given ionic strength and applied osmotic pressure, the nuclear proteins attained a higher protein concentration than did the cortical proteins. For example, at the highest osmotic pressure of 1.15 x 10(6) dyn cm-2 at pH 7.6 and 0.1 M ionic strength, the observed protein concentrations were 0.43 g ml-1 for the cortical proteins and 0.52 g ml-1 for the nuclear proteins. For both cortical and nuclear steer crystallins, the pressure rose more steeply with concentration than do pressures for calf crystallins described in the literature. The impact of these developmental differences in osmotic pressure on lens transparency is discussed. Both the nuclear and cortical crystallins exhibited ionic strength-dependent shifts in their pressure-concentration behavior. At 0.02 M ionic strength, higher pressures were observed, whereas at 0.4 M ionic strength lower pressures were observed for a given protein concentration. The crystallins were also found to equilibrate to different protein concentrations at a constant osmotic pressure and 0.1 M ionic strength over a pH range of 4-9, with a maximum concentration around pH 5 for the cortical crystallins and pH 6 for the nuclear crystallins. Thus, the adult bovine cortical and nuclear soluble lens extracts are different in their osmotic properties, reflecting underlying differences in protein composition. The results of the ionic strength and pH experiments suggest that hard-sphere, electrostatic, and Donnan forces contribute to the total colloid osmotic pressure of the lens crystallins. However, near physiologic pH and ionic strength the charges of the proteins are screened to the extent that the colloid osmotic pressure exhibits only minor changes for large changes in ionic conditions. The differences in the osmotic behavior of the cortical and nuclear proteins are consistent with a model where regional variations in the colloid osmotic properties of the proteins across the lens help support the radial refractive index gradient that is present in vertebrate lenses. The importance of a radial concentration gradient of metabolites is also discussed.

Aging↗

Differential strain measurement using multiplexed fiber Bragg grating sensors.

We investigate differential measurement of strain using fiber Bragg gratings and spatial demultiplexing methods. Differential measurement is shown to improve strain resolution in the presence of noise by an average of 34% compared to absolute measurements of the Bragg wavelengths. Spatial demultiplexing of the gratings provides potentially high-resolution sensing without calculating the sensor wavelengths. The differential method is still temperature dependent. We apply the differential technique to the problem of oil-water boundary detection in production columns, with promising preliminary results.

Algorithms↗

Using a differential refractive index detector as a pressure transducer for online viscometry in exclusion chromatography.

A differential refractive index (DRI) detector was tested as a pressure transducer for single capillary online viscometry in exclusion chromatography. The relationship between the detector response and pressure is linear, in agreement with the theoretically expected influence of pressure on refractive index and its dependence on temperature is negligible. Whole polymer and local intrinsic viscosities were determined and compared for narrow and, respectively, broad molecular weight distribution polymer samples. Considering that the detection system described can be improved, the results suggest that modern DRI detectors are susceptible to satisfy the requirements for a suitable pressure transducer in this application.

Chromatography, Gel↗

Determination of inulin in meat products by high-performance liquid chromatography with refractive index detection.

Inulin is a naturally occurring carbohydrate with beneficial nutritional and technological properties. A high-performance liquid chromatographic (HPLC) method was developed for the quantitative determination of these beta-fructans in meat products, containing this type of additive. The method includes extraction of inulin with hot water, followed by hydrolysis with inulinase enzyme, and determination of the released fructose by HPLC with refractive index detection. An internal standard of rhamnose was used to quantify fructose. The method incorporates a sample blank (without inulinase hydrolysis) for each specimen to subtract contributions of free fructose and fructose from sucrose. The results showed good precision with average RSDs of 2.4% for repeatability and 5.2% for reproducibility. Analytical recovery ranged from 102 to 106%. Satisfactory linearity (r=0.999) was obtained.

Chromatography, High Pressure Liquid↗

On-column refractive index detector for flash chromatography.

A universal detector for on-column analysis in flash chromatography is reported. The detection scheme takes advantage of refractive index changes as analytes move through an illuminated region of the column. The column packing material is a diffuse scattering medium when the refractive index of the solvent is significantly different than that of the packing material. The magnitude of the 'signal' depends on the degree to which the refractive index mismatch is changed. An empirical model that qualitatively accounts for the observed trends is presented. This detection scheme provides a simple, inexpensive means to monitor the end of a flash chromatography column in order to determine the exit time of the species of interest, thus greatly reducing the post-column analysis time. Additionally, the detector is movable along the length of the column, offering the potential to monitor separations as they occur.

Calibration↗

Training software for high-performance liquid chromatography.

A computer simulation program of reversed-phase high-performance liquid chromatography was developed for training purposes. Experimental retention values of 75 organic compounds on a reversed-phase column at four different percentages of organic modifiers were reduced to a two-parameter retention model with the modifier content as variable. Modifiers used were acetonitrile, methanol and tetrahydrofuran. Isocratic and programmed solvent composition were included together with the usual experimental parameters available in modern HPLC equipment, such as UV diode array and refractive index detection. Instrument specifications were made variable within wide ranges. Detailed dispersion data were made available as tabulated output.

Chromatography, High Pressure Liquid↗

Identification and quantification of molecular species of diacyl glyceryl ether by reversed-phase high-performance liquid chromatography with refractive index detection and mass spectrometry.

We have developed a method to identify and quantify the molecular species of diacyl glyceryl ether (DAGE) using high-performance liquid chromatography (HPLC) equipped with a refractive index detector and an electrospray ionization and time of flight mass spectrometer (LC-RI-MS). An octadecyl silica column with a mixture of acetonitrile and dichloromethane (65:35, v/v) as an eluant was used for the HPLC. When the LC-RI-MS method was applied to a mixture of synthetic DAGEs; 1-O-hexadecyl-2,3-dioleoylglycerol (O-16:0-18:1-18:18:1), 1-O-octadecyl-2,3-dioleoylglycerol (O-18:0-18:1-18:1), 1-O-octadecenyl-2,3-dioleoylglycerol (O-18:1-18:1-18:1), 1-O-octadecyl-2,3-didocodahexaenoylglycerol (O-18:0-22:6-22:6), and 1-O-octadecenyl-2,3-didocosahexaenoylglycerol (O-18:1-22:6-22:6), good separation and quantification were obtained on the refractive index chromatogram. A pseudo-molecular ion [M+NH4]+ and a monoacyl glyceryl ether ion [M-RCO2] + were observed for all synthetic DAGEs on the mass spectrum. It was found that the fatty acids and glyceryl ether in DAGE could be easily identified by these mass spectra. When this LC-RI-MS method was applied to the DAGEs extracted from muscle of Stromateus stellatus, approximately 18 peaks were observed on LC-RI-MS chromatograms and the major molecular species of DAGEs were identified as O-16:0-18:1-18:1.

Animals↗