UNEVEN VENTILATION IN PULMONARY TUBERCULOSIS.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Levodropropizine is a recently developed, peripherally active antitussive agent which is widely used in clinical practice. In order to obtain further information on the spectrum of activity of this compound in experimental clinical models, a double-blind controlled study was carried out to evaluate the potential effect of the drug against cough and bronchoconstriction induced by inhalation of an ultrasonically nebulized solution of distilled water in patients with obstructive lung disease. Twenty patients were randomly divided into two groups, which received levodropropizine (60 mg t.i.d.) or placebo respectively for 7 consecutive days. Parameters evaluated at baseline and on the last day of treatment included (i) results of respiratory function tests (FEV1, IVC, FVC, TIFF, PEF, MEF75, MEF50, MEF25) performed before the stimulation test with nebulized water; (ii) total number of coughs during a 2-hour period after the stimulation test; (iii) bronchial responsiveness, quantified by calculating the volume of nebulized water required to induce a 20% reduction of FEV1 below the basal level. At pretreatment, the tussive response was very similar in the two groups. A significant decrease in number of coughs (from 34.4 +/- 8.4 at baseline to 15.6 +/- 4.9 post-treatment, p less than 0.01) was observed after administration of levodropropizine, whereas placebo treatment produced no significant effect (number of coughs: 29.6 +/- 4.9 at baseline vs 24.8 +/- 9.6 post-treatment, N.S.). Bronchial responsiveness decreased significantly (compared to baseline) in both treatment groups, without any significant difference between drug and placebo. Respiratory function tests were not significantly affected by either treatment.(ABSTRACT TRUNCATED AT 250 WORDS)
BACKGROUND: The effects of a local anesthetic delivered through a catheter inserted in the extrapleural region by a surgeon and an analgesic agent given systemically on pain after thoracotomy were assessed. METHODS: The patients in group I (n = 25) had a catheter inserted between the parietal pleura and the endothoracic fascia by a surgeon, and 0.5% bupivacaine was given through this catheter. Another 25 patients (group II) had metamizol given intravenously. Respiratory function tests, arterial blood gases, range of shoulder motion, and postoperative pain were evaluated for each group. Bupivacaine and metamizol were given just before finishing the thoracotomy and then repeated every 4 hours for 3 days. RESULTS: There was no statistical difference in arterial blood gases between the groups (P >.05). There were statistically significant differences in the respiratory function tests, range of shoulder motion, and visual analogue scale (P <.05) between the groups. Group I had fewer complications than group II. There was no mortality in either group. CONCLUSIONS: Bupivacaine given through a catheter to the extrapleural region before finishing thoracotomy is substantially beneficial for the prevention of postoperative pain and reduction of postoperative complications.
The design of a microcomputer-controlled ventilator for automatic performance of lung function and circulatory tests has been described. It incorporates the characteristics of normal mechanical ventilation and also allows one to perform a multitude of test procedures for lung function and circulatory studies in paralyzed animals. The major components of the setup are a pump assembly with solenoid valves to direct gas flow, an electromechanical servo system, and a MS-DOS microcomputer system. The pump assembly has been constructed as a relatively simple device. Great versatility is created by the use of a microcomputer for the control of the ventilator. The software can be easily adapted to several other types of experimental studies. Besides the keyboard input the ventilator can be controlled by a remote computer system. This allows one to run an experimental protocol automatically and to use it in closed-loop servo ventilation. The flexibility in the choice of the respiratory parameters makes the ventilator suitable for lung function and circulatory studies during artificial ventilation. The ventilator has been successfully used in different animal studies during the last 6 yr.
The strength of the respiratory muscles can be evaluated from static measurements (maximal inspiratory and expiratory pressures, MIP and MEP) or inferred from dynamic maneuvers (maximal voluntary ventilation, MVV). Although these data could be suitable for a number of clinical and research applications, no previous studies have provided reference values for such tests using a healthy, randomly selected sample of the adult Brazilian population. With this main purpose, we prospectively evaluated 100 non-smoking subjects (50 males and 50 females), 20 to 80 years old, selected from more than 8,000 individuals. Gender-specific linear prediction equations for MIP, MEP and MVV were developed by multiple regression analysis: age and, secondarily, anthropometric measurements explained up to 56% of the variability of the dependent variables. The most cited previous studies using either Caucasian or non-Caucasian samples systematically underestimated the observed values of MIP (P < 0.05). Interestingly, the self-reported level of regular physical activity and maximum aerobic power correlates strongly with both respiratory and peripheral muscular strength (knee extensor peak torque) (P < 0.01). Our results, therefore, provide a new frame of reference to evaluate the normalcy of some useful indexes of respiratory muscle strength in Brazilian males and females aged 20 to 80.
Respiratory function tests have been performed on schoolchildren in Zaria, Nigeria, to determine normal values among healthy children. Three hundred and eighty-eight students, comprising 257 male and 131 female children, from the Government Day Secondary School were included in this study. The forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV1), forced mid-expiratory flow (FMF 25-75%) and forced expiratory flow were measured using the vitalograph apparatus. It was observed from the results that the mean values of respiratory function tests in boys were significantly higher (P less than 0.01) than the mean values matched for age, height and weight in female children. It was also observed that the values obtained in the present study were lower than those for Caucasian children. However, it was observed that FVC, FEV1 and FMF 25-75% correlated significantly with age, height, weight and body surface area.
Explore the source record for details and available documents.
Oxygen saturation (SaO2) during sleep and pulmonary functions were evaluated in 19 infants with congenital heart disease, aged 6 +/- 4 months, and in 11 normal infants, aged 8 +/- 5 months, to determine whether infants with congenital heart disease have more frequent oxygen desaturation during sleep and, if so, its relationship to underlying pulmonary function. Infants with congenital heart disease were classified as acyanotic (n = 11) or cyanotic (n = 8) on the basis of their aortic SaO2 at the time of cardiac catheterization (greater or less than 90% SaO2). Pulmonary function tests included respiratory rate, functional residual capacity, total respiratory system compliance, and maximal flows at functional residual capacity. Significant differences were found in the values for the lowest SaO2 of each 5-minute epoch (SaO2L) averaged during the entire sleep time (normal 94% +/- 2%, acyanotic 90% +/- 3%, and cyanotic 74% +/- 4%; p less than 0.01). The three groups also differed significantly in frequency distributions of percentage of total sleep time with SaO2L less than 90% (SaO2%T) (normal 10% +/- 17%, acyanotic 36% +/- 34%, and cyanotic 97% +/- 4%; p less than 0.05). Compared with the control group, the acyanotic group had a higher respiratory rate (66 +/- 19 breaths/min vs 35 +/- 6 breaths/min; p less than 0.01), a lower tidal volume (65% +/- 29% predicted vs 105% +/- 18% predicted; p less than 0.01), and a lower total respiratory compliance (59% +/- 18% predicted vs 106% +/- 30% predicted; p less than 0.01). A negative correlation existed between SaO2%T and aortic SaO2 (R2 = 0.64; p less than 0.01). We conclude that oxygen desaturation occurs during sleep in infants with congenital heart disease; the presence of desaturation appears to be related to the initial degree of hypoxemia and the presence of abnormal pulmonary function.
Explore the source record for details and available documents.
Explore the source record for details and available documents.