Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polymethacrylic Acids”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Interactions of porphyrin covalently attached to poly(methacrylic acid) with liposomal membranes.

The interactions between the 5-(4-acryloyloxyphenyl)-10,15,20-tritolylporphyrin covalently attached to poly(methacrylic acid) chain (PMA-Po) and phosphatidylcholine liposomes in aqueous solution at different pH values were studied. The binding constants (K(b)) for the liposome- PMA-Po in solutions in the pH range from 6.5 to 9.2 were determined using fluorescence spectroscopy. The binding was found to be efficient. The acid-base properties of the porphyrin chromophores were also studied. Both pK values associated with imine-N protonation of the porphyrin core were found to be 6.4. The quantum yield (Phi(Delta)) of singlet oxygen production by Po in the lipid-PMA-Po system was found to be high (0.88 +/- 0.05).

Acrylates↗

Propranolol:methacrylic acid copolymer binding interaction.

The polyanionic form of methacrylic acid:methacrylic acid methyl ester copolymer reacts readily with propranolol.HCl to give a sparingly soluble complex at saturation equilibrium. Propranolol: methacrylic acid copolymer complex is characterized by differential thermal analysis, and IR and UV spectroscopic methods. Propranolol content is found to be 68% in the complex. The value of the Hill coefficient (1.5) indicates that there is a high degree of positive cooperative interaction between propranolol and the polymer.

Allosteric Regulation↗

The use of inverse gas chromatography to assess the acid-base contributions to surface energies of cefditoren pivoxil and methacrylate copolymers and possible links to instability.

It is known that acids and bases when mixed together have the potential to react, however, there is complexity when materials are in the solid state, as the surface of the solids may not have all functional groups of the molecule expressed in equal proportions. Conceptually a drug that is acidic when in solution could have a crystal surface that is largely basic (if the acid groups are aligned away from the surface). The interaction of cefditoren pivoxil (a basic drug when dissolved) and various Eudragit polymers was studied. The drug was chemically unstable with Eudragit EPO (basic) and stable with Eudragit L100 or S100 (both acidic). Thus, the hypothesis of this work was that the surface of these materials had a different nature to the dissolved molecules, such that solid state reactions do not proceed in line with the expectation from the solution state. Inverse phase gas chromatography (IGC) was used to investigate the cefditoren pivoxil and the Eudragits. The basic to acidic parameter ratios (K(D)/K(A)) on the powder surface of the samples by IGC revealed that surface nature was in keeping with the tendency to react, such that the incompatibility could be due to the acid-base interaction between any carbonyl groups having an amphoteric nature on the surface of cefditoren pivoxil crystal and dimethylaminoethyl groups having a basic nature on the powder surface of Eudragit EPO. This study indicated that IGC would be suitable to elucidate the cause of incompatibility between two different solids.

Anti-Bacterial Agents↗

Enzymes in polyelectrolyte complexes. The effect of phase transition on thermal stability.

Penicillin amidase, alpha-chymotrypsin and urease have been immobilized in water-soluble nonstoichiometric polyelectrolyte complexes (N-PEC). N-PEC are formed by modified poly(N-ethyl-4-vinyl-pyridinium bromide) (polycation) and excess poly(methylacrylic acid) (polyanion). N-PEC are a new class of polymers capable, characteristically, of phase transitions solution in equilibrium precipitate induced by slight change in pH or ionic strength. Neither the chemical structure of the carrier nor the number of cross-linkages between an enzyme and a carrier change on phase transition. That gives an unique opportunity to elucidate the difference between enzymes immobilized on water-soluble and water-insoluble supports. A detailed study of the phase transition effect on thermal stability of the enzymes and protein-protein interactions has been carried out. The following effects were found. Pronounced thermal stabilization of penicillin amidase and urease may be achieved on two conditions: the enzyme is in the precipitate; (b) the enzyme is linked to the N-PEC nucleus. Then the thermal stability of N-PEC-bound penicillin amidase increases 7-fold at pH 5.7, 60 degrees C, and 300-fold at pH 3.1, 25 degrees C, compared to the native enzyme. For urease, the thermal stabilization increases 20-fold at pH 5.0, 70 degrees C. The localization of enzyme on N-PEC has been established by titration of alpha-chymotrypsin bound to a polycation or polyanion with basic pancreatic trypsin inhibitor. Both in solution (pH 6.1) and in N-PEC precipitate (pH 5.7), an alpha-chymotrypsin molecule bound to a polyanion is fully exposed to the solution. If the enzyme is bound to a polycation, only 20% of alpha-chymotrypsin molecules in the precipitate and 40% in solution retain their ability for protein-protein interactions. This means that a polycation-bound enzyme is localized in the hydrophobic nucleus of the complex, whereas the polyanion-bound enzyme sits on the hydrophilic shell of the complex. On pH-induced phase transition (pH decreases from 6.1 to 5.7), there occurs a stepwise decrease in penicillin amidase activity which is due to a 9.8-fold increase in the Km for 2-nitro-4-phenylacetamidobenzoic acid. Change of the catalytic activity and thermal stability of N-PEC-bound penicillin amidase is fully reversible and reproducible. Such soluble-insoluble immobilized enzymes with controllable thermal stability and activity may be used for simulating events in vivo and in biotechnology.

Chymotrypsin↗

A hematoxylin and eosin-like stain for glycol methacrylate embedded tissue sections.

A staining procedure is described for use with glycol methacrylate embedded tissue sections which does not stain the plastic embedment or remove the sections from the glass slides. The basic dye is celestine blue B. It is prepared by treating 1 g of the dye with 0.5 ml concentrated sulfuric acid. It is then dissolved with the following solution. Add 14 ml glycerine to 100 ml 2.5% ferric ammonium sulfate and warm the solution to 50 C. Finally adjust the pH to 0.8 to 0.9 The acid staining solution consists of 0.075% ponceau de xylidine and 0.025% acid fuchsin in 10% acetic acid. Slides containing the dried plastic sections are immersed in the celestine blue solution for five minutes and in the ponceau-fuchsin solution for ten minutes with an intervening water rinse. After a final wash, the sections are air dried and coverslipped. This staining procedure colors the tissues nearly the same as hematoxylin and eosin procedures.

Animals↗

[Study of a high molecular copolymer HFMC in vaginal irrigation for contraception in mice].

A vaginal spermicide of high molecular copolymer, ethyl methacrylate-methacrylic acid-hydroxyethyl methacrylate (HFMC), was introduced through a small tube into the mouse's vagina and made to adhere to it's wall, causing a pH alteration in the vaginal environment. Matching experiments showed that the sperms were killed or/and lost their mobility and vitality owing to the infertile acidic environment. The fertility could be restored when the HFMC dissolved gradually. But the delivering time was delayed for about 112-118 days versus the control (P less than 0.001). The fertility could also be restored artificially by flushing out the copolymer with solvent DMSO. In this case the delivering time was consistent with the control (P greater than 0.05).

Acrylates↗

Effect of pH on Porphyromonas gingivalis endotoxin affinity for resins.

This study evaluated the effect of pH on Porphyromonas gingivalis lipopolysaccharide (LPS) affinity for polymethyl methacrylate, polyethyl methacrylate, and polyethyl and polyisobutyl methacrylate resins. Specimens were exposed to 1,010 endotoxin units LPS in potassium phosphate buffer at pH 6, pH 7, or pH 8. Control specimens were incubated in LPS-free water. Sequence I evaluated LPS uptake and release from resin when exposure and elution pH were identical, whereas Sequence II evaluated LPS release from resin when elution pH differed from exposure pH. A slightly acidic pH decreased LPS affinity for all resins compared to pH 7. A slightly alkaline pH increased LPS affinity for the polyethyl methacrylate resin but decreased LPS affinity for the others compared to pH 7. The pH may affect resin-LPS affinity by altering LPS molecular charge.

Analysis of Variance↗

Novel mode of contraception using polymeric hydrogels. I.

A new method of fertility control has been proposed and tested. The technique involves the use of the polymer, which when injected into the vas deferens lowers the pH sufficiently so as to kill the spermatozoa passing through. The polymer provides an acidic environment for a prolonged time and slowly erodes. The fertility may be restored after complete solubility of the polymer itself over a period of time or by flushing it with a suitable solvent. This method of male contraception is nonsurgical, nonocclusive, and reversible.

Contraception↗

pH-responsive polymeric micelles of poly(ethylene glycol)-b-poly(alkyl(meth)acrylate-co-methacrylic acid): influence of the copolymer composition on self-assembling properties and release of candesartan cilexetil.

The objective of the present study was to investigate the influence of chemical structure and molecular weight of pH-sensitive block copolymers on their self-assembling properties, the loading and the release of candesartan cilexetil (CDN). Block copolymers of poly(ethylene glycol) and t-butyl methacrylate, iso-butyl acrylate, n-butyl acrylate or propyl methacrylate were synthesized by atom transfer radical polymerization. pH-sensitivity was obtained by hydrolysis of t-butyl groups. The poorly water-soluble drug CDN was incorporated in the micelles and the in vitro drug release was evaluated as a function of pH. The critical aggregation concentration of hydrolyzed copolymers (pK(a)=6.2-6.6) was higher compared to the unhydrolyzed ones. Dynamic light scattering studies and atomic force microscopy images revealed uniform size micelles with aggregation numbers ranging from 60 to 160. The entrapment efficiency of CDN was generally found to be above 90%, with drug loading levels reaching approximately 20% (w/w). Differential scanning calorimetry studies showed the amorphous nature of entrapped CDN. The release of CDN from pH-sensitive micelles was triggered upon an increase in pH from 1.2 to 7.2. These findings suggest that the PEG-b-poly(alkyl(meth)acrylate-co-methacrylic acid)s can self-assemble to form micelles which exhibit high loading capacities for CDN and release the drug in a pH-dependent fashion.

Angiotensin II Type 1 Receptor Blockers↗

Surface energy characteristics of adhesive monomers.

OBJECTIVES: The aim of the investigation was to determine the surface free-energy components of potentially adhesive monomer mixtures. METHODS: Four liquids with known components of surface free-energy were used as reference. Small drops of the liquids were placed on the polished surfaces of four types of solid (metal, porcelain, resin composite and hydrocarbon), and the contact angles were measured. By means of the fundamental equations for wetting, the three components of the surface free-energy of the four solids were calculated. Small drops of various monomeric mixtures were then placed on the four solid surfaces, and on the basis of the previously calculated components of surface free-energy of the solids, the surface energy characteristics of the monomeric mixtures were determined. The relationships between contact angles and composition, and between surface tension and composition, were studied by regression analyses. Comparisons between values were carried out by means of Neuman-Keuls' multiple range test at a level of statistical significance of p = 0.05. RESULTS: Statistically significant differences between the monomeric mixtures as regards the wetting of the four solids were observed. These differences reflected differences in the acid or base component of the surface free-energy of the monomers. In particular, monomeric mixtures containing HEMA, MAN or 4-META exhibited a significant acid component of the surface free-energy. SIGNIFICANCE: Knowledge of the surface free-energy components of monomers throws light on the mechanisms associated with the adhesion of resin composites, including resin cements. A better understanding of the interfacial interactions may act as guide in a research aimed at developing resin materials of increased adhesion to metal, porcelain or resin composite.

Adhesives↗

Influence of NaOCl deproteinization on shear bond strength in function of dentin depth.

PURPOSE: To determine the influence of NaOCl application on shear bond strengths (SBS) to superficial and deep dentin, using Prime & Bond 2.1. MATERIALS AND METHODS: Superficial and deep dentin was exposed in 40 extracted third molars by sectioning the occlusal surface immediately under the enamel-dentin junction or close to the pulp chamber. After polishing the dentin disks (600-grit SiC), they were assigned to two groups: (1) 36% orthophosphoric acid for 15 seconds, or (2): 36% orthophosphoric acid for 15 seconds followed by 5% sodium hypochlorite (NaOCl) for 2 minutes. The dentin adhesive was applied as per manufacturer's instructions, followed by TPH resin-based composite. The specimens were stored in water for 24 hours at 37 degrees C and thermocycled x500 and SBS were determined. Data were statistically analyzed with ANOVA and Student's t-test. RESULTS: For acid-etched specimens, superficial dentin resulted in statistically higher mean SBS than deep dentin. After NaOCl application, deep and superficial dentin resulted in statistically similar mean SBS. Collagen removal did not affect mean SBS on superficial dentin, while SBS values on deep dentin were increased.

Acetone↗

Evaluation of a new coated charcoal for hemoperfusion in uremia.

A new coated charcoal for hemoperfusion in uremia was investigated in 14 patients with end stage renal disease who underwent hemoperfusion or combined hemodialysis-hemoperfusion (39 seances). Investigations concerned removal of small molecules, coagulation and hematological status and amino acids and some hormones equilibrium. Clinical observations were also made in all patients. The methacrylate-coated charcoal enabled the removal of "toxins" up to 5000 daltons and the total solute removal did not significantly differ from previous hemoperfusion systems. However, the new coating membrane showed improved biocompatibility, in terms of clinical side effects and/or platelet and fibrinogen alterations.

Biocompatible Materials↗

Effect of removal of surface collagen fibrils on resin-dentin bonding.

OBJECTIVES: The aim of this study was to evaluate the effects of NaOCl at removing the demineralized layer by examining the morphology of the hybrid layer and measuring shear bond strengths after different dentin treatments. METHODS: Dentin disks were treated with: (1) 35% phosphoric acid (PA) 20 s; (2) PA treatment followed by 1.5% NaOCl, 2 min; (3) PA treatment, followed by a 10% NaOCl immersion for 120 h. SEM was used to analyze the morphology of dentin and its interface with dentin bonding agents (DBAs), while shear bond strength tests were used to measure adhesion. All specimens were then fractured into two halves: One half was inspected under SEM; the other half was sequentially placed in 10% PA followed by 12.5% NaOCl for 70 h, to remove all dentin from the resin replica of the original bonded interface. RESULTS: SEM observations showed that collagen fibrils were completely removed from the acid-etched surface by NaOCl treatment. The diameter and the size of dentinal tubules and the number of lateral branches of the tubules were increased following NaOCl treatment. NaOCl applied on dentin smear layers did not significantly modify their SEM morphology. Resin tags were larger in diameter after phosphoric acid/NaOCl treatment than after only phosphoric acid treatment. Resin-infiltrated dentin-layers were only observed after the single phosphoric acid (i.e. conventional etching) procedure, and were not observed after combined phosphoric acid/NaOCl treatment. Etched/NaOCl samples showed a lower bond strength using Scotchbond MP and 3M Single Bond, but were higher in Optibond FL and unmodified in Prime & Bond 2.0 groups when compared with acid-etched controls. Treatment of etched dentin with NaOCl for 120 h produced an unusual type of resin infiltration of mineralized dentin that could be called a "reverse hybrid layer" which may explain the mechanism of resin bonding to NaOCl treated dentin. SIGNIFICANCE: The use of acidic conditioners for exposure of the collagen matrix exposes a soft delicate mesh that can collapse, thereby interfering with resin infiltration. If acid-etching is followed by NaOCl treatment, high bond strengths can be achieved via "reverse hybrid layer" formation, a proposed new mechanism of micromechanical resin retention. This mechanism is not yet recommended for clinical use but demonstrates a new type of resin retention.

Adolescent↗

Allergic contact dermatitis to artificial fingernails prepared from UV light-cured acrylates.

BACKGROUND: Contact dermatitis from artificial nails made from self-curing acrylic resins is occasionally reported. Recently, UV light-cured products introducing new acrylics have become available. OBJECTIVE: Our purpose was to identify relevant allergens in commercial light-curing products by patch tests and to evaluate the efficacy of "hypoallergenic" products by inclusion into the test series. METHODS: Patients wearing photobonded acrylic nails who had perionychial and subonychial eczema were patch tested with an acrylate battery and "hypoallergenic" commercial products. RESULTS: Triethyleneglycol dimethacrylate, hydroxyfunctional methacrylates, and (meth)-acrylated urethanes proved to be relevant allergens in photobonded nail preparations. Methacrylated epoxy resin sensitization was not observed. All "hypoallergenic" products provoked positive reactions. CONCLUSION: The omission of irritant methacrylic acid in UV-curable products does not reduce the high sensitizing potential of new acrylates. In contrast to the manufacturers' declarations, all "hypoallergenic" products continue to include acrylate functional monomers and therefore continue to cause allergic sensitization.

Acrylates↗

Long-term fluoride release from a glass ionomer cement, a compomer, and from experimental resin composites.

The aqueous phase of glass ionomer cements enables fluoride ions to diffuse and to be released from the material. The matrix of resin composites is much less hydrophilic, and fluoride incorporated in the material is only released in small amounts. It was the purpose of the present work to study the influence of resin matrix formulation on the fluoride release from experimental, fluoride-containing resin composites. The resin composites were based on methacrylate monomers and the adduct of maleic anhydride and HEMA (2-hydroxyethyl methacrylate). The resin composites contained 1 w% or 5 w% of AlF3*3H2O. A glass ionomer cement and a compomer were used as controls. Five disks of each material were stored in distilled water at room temperature. By means of a fluoride sensitive electrode, the fluoride release from disk-shaped specimens was determined periodically over 3 years. The glass ionomer cement released the most fluoride (1.54 +/- 4 microg/cm2 after 1 year and 248 +/- 7 microg/cm2 after 3 years). The compomer released relatively little fluoride during the 1st year (30 +/- 1 microg/cm2) but after this time the rate of fluoride release became equal to that of the glass ionomer cement, resulting in a release of 122 +/- 8 microg/cm2 after 3 years. Regarding the resin composites, the fluoride release increased with the hydrophilicity and the acid character of the polymer matrix. The release, however, was significantly lower than that from the glass ionomer cement and the compomer and ranged from 1.2 +/- 0.07 to 42 +/- 3.9 microg/cm2 at 1 year and from 2.3 +/- 0.16 to 79 +/- 6 microg/cm2 at 3 years.

Aluminum Compounds↗

Class V restorations utilizing a new compomer material: a case presentation.

Restorative materials used in the anterior cervical region should be able to restore the affected area in an aesthetic manner, require only a minimal amount of tooth structure removal, and provide protection from further cervical decalcification. The latest generation of restorative materials have combined the qualities of composite resins and glass-ionomers. Some of these materials incorporate resin components into glass-ionomer systems and are termed resin-modified glass-ionomers; others add glass-ionomer particles to acidic polymerizable monomers in a resin matrix and are commonly called "compomers." The learning objective of this case report is to present a step-by-step clinical procedure for restoration of a Class V defect in the maxillary anterior region, using a recently introduced "compomer."

Adult↗

Adverse surface interactions between one-bottle light-cured adhesives and chemical-cured composites.

OBJECTIVES: This study examined the effect of one-bottle adhesives with different acidities on bonding to chemical-cured and light-cured resin composites. METHODS: Twenty-four non-carious human third molars were divided into eight groups. A flat dentin surface was created for each tooth. Acid-conditioned dentin surfaces were bonded with Prime&Bond NT (Dentsply), OptiBond SOLO (Kerr), Single Bond (3M) or One-Step (Bisco). Each adhesive group was covered with composite buildups, using either a light-cured (Z100, 3M) or a chemical-cured composite (BisFil 2, Bisco). Specimens were vertically sectioned into 0.9x0.9 mm beams. Microtensile bond strengths were recorded and failure modes were classified using a stereoscopical microscope. Four representative beams from each group were further prepared for SEM examination. RESULTS: Two-way ANOVA showed that the effect of adhesive types, composite curing modes and their interaction were statistically significant (P<0.001). Multiple comparison tests revealed no statistically significant difference in the bond strength of the four adhesives with the light-cured composite (P>0.05). However, they were significantly lower when used with the chemical-cured composite (P<0.01). A positive correlation was observed between the acidity of adhesives and the bond strengths of the chemical-cured composite. Failure occurred predominantly along the composite-adhesive interface, with microporosities on the adhesive surface and voids within the chemical-cured composite. SIGNIFICANCE: Air incorporated during mixing of chemical-cured composites only contributed partially to the decreased bond strength observed in simplified-step adhesives. Ultrastructural observations suggested the presence of a surface interaction between the uncured, acidic resin monomers from the oxygen inhibition layer of the adhesive and the initiator components in the chemical-cured composite.

Acrylic Resins↗

A comparative study of fluoride-releasing adhesive resin materials.

One of the most important and exciting properties of recently introduced dental restorative materials is their ability to release fluoride ions, as this has several advantageous effects on tooth structures. They have been extensively used as fluoride-releasing filling and luting materials. Recently, fluoride-releasing adhesive resins and fluoride-releasing adhesive resin cement have been developed and introduced for clinical use. The purpose of this study was to evaluate the fluoride release from these adhesive resins and the fluoride uptake by both enamel and dentin, as well as the acid-resistance of these tooth structures. Based on our results, we conclude that fluoride-releasing adhesive resins and luting cements are useful for the prevention of initial or secondary caries, especially along the margins of restorations.

Cariostatic Agents↗