Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Optical coherence tomography: an emerging technology for biomedical imaging and optical biopsy.

Optical coherence tomography (OCT) is an emerging technology for performing high-resolution cross-sectional imaging. OCT is analogous to ultrasound imaging, except that it uses light instead of sound. OCT can provide cross-sectional images of tissue structure on the micron scale in situ and in real time. Using OCT in combination with catheters and endoscopes enables high-resolution intraluminal imaging of organ systems. OCT can function as a type of optical biopsy and is a powerful imaging technology for medical diagnostics because unlike conventional histopathology which requires removal of a tissue specimen and processing for microscopic examination, OCT can provide images of tissue in situ and in real time. OCT can be used where standard excisional biopsy is hazardous or impossible, to reduce sampling errors associated with excisional biopsy, and to guide interventional procedures. In this paper, we review OCT technology and describe its potential biomedical and clinical applications.

Animals↗

Magnetic resonance imaging of optic gliomas.

We compared magnetic resonance imaging of the optic nerves and chiasm with computed tomography in four patients (a 17-year-old girl, a 14-year-old boy, a 13-year-old girl, and a 22-year-old woman) with biopsy-proven or suspected optic gliomas. Orbital abnormalities were effectively viewed by both techniques. Gliomatous and normal optic nerves had similar spin-echo magnetic resonance imaging characteristics. Magnetic resonance was superior to contrast-enhanced computed tomography for identification of the intracranial optic nerves, chiasm, and optic tracts, but computed tomography delineated orbital anatomic and spatial relationships better.

Adolescent↗

Analyzing Sub-Classifications of Glaucoma via SOM Based Clustering of Optic Nerve Images.

We present a data mining framework to cluster optic nerve images obtained by Confocal Scanning Laser Tomography (CSLT) in normal subjects and patients with glaucoma. We use self-organizing maps and expectation maximization methods to partition the data into clusters that provide insights into potential sub-classification of glaucoma based on morphological features. We conclude that our approach provides a first step towards a better understanding of morphological features in optic nerve images obtained from glaucoma patients and healthy controls.

Algorithms↗

The prospects for high resolution optical brain imaging: the magnetic resonance perspective.

Various analogs of NMR and MRI are now technically possible in optics; specifically, high-resolution laser-pulse shaping and complex pulse sequence generation with well-defined phase shifts has been demonstrated. Here we summarize this technology and discuss the potential for these methods to enhance optical functional imaging, competing with (and surpassing?) what is possible by functional MRI.

Brain↗

Coregistered tomographic x-ray and optical breast imaging: initial results.

We describe what is, to the best of our knowledge, the first pilot study of coregistered tomographic x-ray and optical breast imaging. The purpose of this pilot study is to develop both hardware and data processing algorithms for a multimodality imaging method that provides information that neither x-ray nor diffuse optical tomography (DOT) can provide alone. We present in detail the instrumentation and algorithms developed for this multimodality imaging. We also present results from our initial pilot clinical tests. These results demonstrate that strictly coregistered x-ray and optical images enable a detailed comparison of the two images. This comparison will ultimately lead to a better understanding of the relationship between the functional contrast afforded by optical imaging and the structural contrast provided by x-ray imaging.

Aged↗

Optical molecular imaging of lymph nodes using a targeted vascular contrast agent.

We develop a highly specific antibody-dye conjugate for optical imaging of peripheral lymph nodes. The contrast agent consists of the monoclonal antibody recognizing endothelial ligands for the lymphocyte homing receptor L-selectin, MECA-79, and a near-infrared (near-IR) fluorescent indotricarbocyanine dye. The targeting and biodistribution behavior of MECA-79 is studied after radio-iodination and intravenous injection into mice demonstrating specific uptake in lymph nodes and accumulation in high endothelial venules (HEV). After conjugation of MECA-79 with indotricarbocyanine dye, the fluorescence imaging properties of the MECA-79 dye conjugate are examined by intravenous injection in nude mice and laser-induced fluorescence whole-body imaging in vivo. The MECA-79 antibody-dye conjugate accumulates in peripheral lymph nodes, whereas an isotype antibody-dye conjugate does not. Specific lymph node near-IR fluorescent signals become detectable within minutes after injection, and stable imaging persists for more than 24 h. The results demonstrate that vascular targeting of endothelial expression of glyocproteins is feasible to visualize the accumulation of near-IR fluorescent MECA-79 in lymph nodes, making this technology potentially useful to characterize processes of inflammation.

Animals↗

Tomographic optical breast imaging guided by three-dimensional mammography.

We introduce a modified Tikhonov regularization method to include three-dimensional x-ray mammography as a prior in the diffuse optical tomography reconstruction. With simulations we show that the optical image reconstruction resolution and contrast are improved by implementing this x-ray-guided spatial constraint. We suggest an approach to find the optimal regularization parameters. The presented preliminary clinical result indicates the utility of the method.

Breast↗

Magnetic resonance imaging of optic perineuritis.

Optic perineuritis, an uncommon variant of orbital pseudotumor, may be clinically indistinguishable from retrobulbar optic neuritis. Because treatment and prognosis for these two entities are different, early diagnosis is important. We report a case of a 47 year-old woman with clinical findings suggestive of retrobulbar optic neuritis, but whose magnetic resonance images suggested optic perineuritis. A dramatic clinical response to oral corticosteroids was observed. Optic perineuritis should be considered in cases of presumed retrobulbar optic neuritis. MRI may differentiate these two entities in the acute stage, and should be considered before treatment is decided.

Contrast Media↗

Hertel exophthalmometry versus computed tomography and optical 3D imaging for the determination of the globe position in zygomatic fractures.

It has been the aim of the present study, to introduce the combination of computed tomography and optical 3D imaging to exophthalmometry and to compare the resulting data to the classic Hertel method. Twenty patients without orbital pathology and 12 patients were included in the study, who were subjected to a preoperative computed tomography. Optical 3D images of the facial surface were assessed and Hertel exophthalmometry was carried out to determine protrusion. In patients with zygomatic fractures the assessment of optical 3D images and Hertel values was repeated 5 days after surgery. Preoperative axial CT slices and postoperative optical contours through the globes were superimposed and the change in protrusion was determined. The protrusion values assessed either by CT, Hertel exophthalmometry or optical 3D imaging for patients without orbital pathology did not show any statistically significant differences between each other. For zygomatic fractures, Hertel exophthalmometry revealed more pronounced protrusion data in four of five cases of a posterolaterally dislocated lateral orbital rim and a higher degree of enophthalmos in cases without dislocation of the lateral orbital rim than it could be proved in the CT slices. The differences between optical measurements and CT data were minimal in patients with zygomatic fractures. The combination of computed tomography as baseline measurement and optical 3D imaging for the follow-up examinations reveal more realistic data in cases of zygomatic fractures than Hertel measurements and should be preferred.

Adult↗

Processing of medical images using real-time optical Fourier processing.

Optical image processing techniques are inherently fast in view of parallel processing. A self-adaptive optical Fourier processing system using photoinduced dichroism in a bacteriorhodopsin film was experimentally demonstrated for medical image processing. Application of this powerful analog all-optical interactive technique for cancer diagnostics is illustrated with two mammograms and a Pap smear. Microcalcification clusters buried in surrounding tissue showed up clearly in the processed image. By playing with one knob, which rotates the analyzer in the optical system, either the microcalcification clusters or the surrounding dense tissue can be selectively displayed. Bacteriorhodopsin films are stable up to 140 degrees C and environmentally friendly. As no interference is involved in the experiments, vibration isolation and even a coherent light source are not required. It may be possible to develop a low-cost rugged battery operated portable signal-enhancing magnifier.

Bacteriorhodopsins↗

Deconvolution of adaptive optics retinal images.

We quantitatively demonstrate the improvement to adaptively corrected retinal images by using deconvolution to remove the residual wave-front aberrations. Qualitatively, deconvolution improves the contrast of the adaptive optics images. In this work we demonstrate that quantitative information is also increased by investigation of the improvement to cone classification due to the reduction in confusion of adjacent cones because of the extended wings of the point-spread function. The results show that the error in classification between the L and M cones is reduced by a factor of 2, thereby reducing the number of images required by a factor of 4.

Algorithms↗

In vivo optical reflectance imaging of spreading depression waves in rat brain with and without focal cerebral ischemia.

Spreading depression (SD) waves occur in focal cerebral ischemia of the brain. Optical reflectance imaging at 550 +/- 10-nm wavelength using a charge-coupled device (CCD) camera, called optical intrinsic signal imaging (OISI) in the neuroscience community, provides high resolution imaging of SD waves based on changes in blood perfusion. We present optical images of SD waves in normal rat brain induced by a pinprick, and the spontaneous SD waves that follow middle cerebral artery occlusion (MCAO). The images of change in reflectance are calculated as A = (I-I(o))I(o), where I is pixel intensity as some timepoint and I(o) is the initial intensity just prior to an SD wave. Difference images B = [I(i)-I(i-1)]I(o), where I(i) is the image at time i and I(i-1) is the previous image at time i-1 (a 6.4-s interval), significantly sharpen the boundaries between leading and trailing edges of the SD wave. Maximum rate-of-change images C = max(B) display the maximum pixel value of B within the duration of a single SD wave, and provide an image that visualizes the entire penumbra. The penumbra appear bright due to a rapid drop in perfusion, while the normal brain and infarct area appear dark.

Animals↗

Time-dependent speckle in holographic optical coherence imaging and the health of tumor tissue.

Holographic optical coherence imaging acquires en face images from successive depths inside scattering tissue. In a study of multicellular tumor spheroids the holographic features recorded from a fixed depth are observed to be time dependent, and they may be classified as variable or persistent. The ratio of variable to persistent features, as well as speckle correlation times, provides quantitative measures of the health of the tissue. Studies of rat osteogenic sarcoma tumor spheroids that have been subjected to metabolic and cross-polymerizing poisons provide quantitative differentiation among healthy, necrotic, and poisoned tissue. Organelle motility in healthy tissue appears as super-Brownian laser speckle, whereas chemically fixed tissue exhibits static speckle.

Animals↗

Holographic optical coherence imaging of rat osteogenic sarcoma tumor spheroids.

Holographic optical coherence imaging is a full-frame variant of coherence-domain imaging. An optoelectronic semiconductor holographic film functions as a coherence filter placed before a conventional digital video camera that passes coherent (structure-bearing) light to the camera during holographic readout while preferentially rejecting scattered light. The data are acquired as a succession of en face images at increasing depth inside the sample in a fly-through acquisition. The samples of living tissue were rat osteogenic sarcoma multicellular tumor spheroids that were grown from a single osteoblast cell line in a bioreactor. Tumor spheroids are nearly spherical and have radial symmetry, presenting a simple geometry for analysis. The tumors investigated ranged in diameter from several hundred micrometers to over 1 mm. Holographic features from the tumors were observed in reflection to depths of 500-600 microm with a total tissue path length of approximately 14 mean free paths. The volumetric data from the tumor spheroids reveal heterogeneous structure, presumably caused by necrosis and microcalcifications characteristic of some human avascular tumors.

Animals↗

A multicompartment vascular model for inferring baseline and functional changes in cerebral oxygen metabolism and arterial dilation.

Functional hemodynamic responses are the composite results of underlying variations in cerebral oxygen consumption and the dilation of arterial vessels after neuronal activity. The development of biophysically based models of the cerebral vasculature allows the separation of the neuro-metabolic and neuro-vascular influences on measurable hemodynamic signals such as functional magnetic resonance imaging or optical imaging. We describe a multicompartment model of the vascular and oxygen transport dynamics associated with stimulus-driven neuronal activation. Our model offers several unique features compared with previous formulations such as the ability to estimate baseline blood flow, volume, and oxygen consumption from functional data. In addition, we introduce a capillary compliance model, arterial and venous oxygen permeability, and model the dynamics of extravascular tissue oxygenation. We apply this model to multimodal optical spectroscopic and laser speckle imaging of the rat somato-sensory cortex during nine conditions of whisker stimulation. By fitting the model using a psuedo-Bayesian framework to incorporate multimodal observations, we estimate baseline blood flow to be 94 (+/-15) mL/100 g min and baseline oxygen consumption to be 6.7 (+/-1.3) mL O(2)/100 g min. We calculate parametric, linear increases in arterial dilation (R(2)=0.96) and CMRO(2) (R(2)=0.87) responses over the nine conditions. Other parameters estimated by the model include vascular transit time and volume reserve, oxygen content, saturation, diffusivity rate constants, and partial pressure of oxygen in the vascular compartments and in the extravascular tissue. Finally, we compare this model to earlier work and find that the multicompartment model more accurately describes the observed oxygenation changes when compared with a single compartment version.

Arteries↗

Long-term voltage-sensitive dye imaging reveals cortical dynamics in behaving monkeys.

A novel method of chronic optical imaging based on new voltage-sensitive dyes (VSDs) was developed to facilitate the explorations of the spatial and temporal patterns underlying higher cognitive functions in the neocortex of behaving monkeys. Using this system, we were able to explore cortical dynamics, with high spatial and temporal resolution, over period of <or=1 yr from the same patch of cortex. The visual cortices of trained macaques were stained one to three times a week, and immediately after each staining session, the monkey started to perform the behavioral task, while the primary and secondary visual areas (V1 and V2) were imaged with a fast optical imaging system. Long-term repeated VSD imaging (VSDI) from the same cortical area did not disrupt the normal cortical architecture as confirmed repeatedly by optical imaging based on intrinsic signals. The spatial patterns of functional maps obtained by VSDI were essentially identical to those obtained from the same patch of cortex by imaging based on intrinsic signals. On comparing the relative amplitudes of the evoked signals and differential map obtained using these two different imaging methodologies, we found that VSDI emphasizes subthreshold activity more than imaging based on intrinsic signals, that emphasized more spiking activity. The latency of the VSD-evoked response in V1 ranged from 46 to 68 ms in the different monkeys. The amplitude of the V2 response was only 20-60% of that in V1. As expected from the anatomy, the retinotopic responses to local visual stimuli spread laterally across the cortical surface at a spreading velocity of 0.15-0.19 m/s over a larger area than that expected by the classical magnification factor, reaching its maximal anisotropic spatial extent within approximately 40 ms. We correlated the observed dynamics of cortical activation patterns with the monkey's saccadic eye movements and found that due to the slow offset of the cortical response relative to its onset, there was a short period of simultaneous activation of two distinct patches of cortex following a saccade to the visual stimulus. We also found that a saccade to a small stimulus was followed by direct transient activation of a cortical region in areas of V1 and V2, located retinotopically within the saccadic trajectory.

Animals↗

Imaging in breast cancer: diffuse optics in breast cancer: detecting tumors in pre-menopausal women and monitoring neoadjuvant chemotherapy.

Diffuse optical spectroscopy (DOS) and diffuse optical imaging (DOI) are non-invasive diagnostic techniques that employ near-infrared (NIR) light to quantitatively characterize the optical properties of centimeter-thick, multiple-scattering tissues. Although NIR was first applied to breast diaphanography more than 70 years ago, quantitative optical methods employing time- or frequency-domain 'photon migration' technologies have only recently been used for breast imaging. Because their performance is not limited by mammographic density, optical methods can provide new insight regarding tissue functional changes associated with the appearance, progression, and treatment of breast cancer, particularly for younger women and high-risk subjects who may not benefit from conventional imaging methods. This paper reviews the principles of diffuse optics and describes the development of broadband DOS for quantitatively measuring the optical and physiological properties of thick tissues. Clinical results are shown highlighting the sensitivity of diffuse optics to malignant breast tumors in 12 pre-menopausal subjects ranging in age from 30 to 39 years and a patient undergoing neoadjuvant chemotherapy for locally advanced breast cancer. Significant contrast was observed between normal and tumor regions of tissue for deoxy-hemoglobin (p = 0.005), oxy-hemoglobin (p = 0.002), water (p = 0.014), and lipids (p = 0.0003). Tissue hemoglobin saturation was not found to be a reliable parameter for distinguishing between tumor and normal tissues. Optical data were converted into a tissue optical index that decreased 50% within 1 week in response to neoadjuvant chemotherapy. These results suggest a potential role for diffuse optics as a bedside monitoring tool that could aid the development of new strategies for individualized patient care.

Adult↗