Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Oligonucleotide Array Sequence Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

probeBase--an online resource for rRNA-targeted oligonucleotide probes: new features 2007.

probeBase is a curated database of annotated rRNA-targeted oligonucleotide probes and supporting information. Rapid access to probe, microarray and reference data is achieved by powerful search tools and via different lists that are based on selected categories such as functional or taxonomic properties of the target organism(s) or the hybridization format (fluorescence in situ hybridization or microarray) in which the probes were applied. Additional information on probe coverage and specificity is available through direct submissions of probe sequences from probeBase to RDP-II and Greengenes, two major rRNA sequence databases. A freely editable user comments field for each probe entry allows any user to add, modify or remove information or to report errors in real-time. probeBase entries increased from 700 to more than 1200 during the past three years. Several options for submission of single probes or entire probe sets, even prior to publication of newly developed probes, should further contribute to keeping probeBase an up-to-date and useful resource. probeBase is freely accessible at http://www.microbial-ecology.net/probebase. Email correspondence can be addressed to probebase@microbial-ecology.net.

Bacteria↗

Multiple primer extension by DNA polymerase on a novel plastic DNA array coated with a biocompatible polymer.

DNA microarrays are routinely used to monitor gene expression profiling and single nucleotide polymorphisms (SNPs). However, for practically useful high performance, the detection sensitivity is still not adequate, leaving low expression genes undetected. To resolve this issue, we have developed a new plastic S-BIO PrimeSurface with a biocompatible polymer; its surface chemistry offers an extraordinarily stable thermal property for a lack of pre-activated glass slide surface. The oligonucleotides immobilized on this substrate are robust in boiling water and show no significant loss of hybridization activity during dissociation treatment. This allowed us to hybridize the templates, extend the 3' end of the immobilized DNA primers on the S-Bio by DNA polymerase using deoxynucleotidyl triphosphates (dNTP) as extender units, release the templates by denaturalization and use the same templates for a second round of reactions similar to that of the PCR method. By repeating this cycle, the picomolar concentration range of the template oligonucleotide can be detected as stable signals via the incorporation of labeled dUTP into primers. This method of Multiple Primer EXtension (MPEX) could be further extended as an alternative route for producing DNA microarrays for SNP analyses via simple template preparation such as reverse transcript cDNA or restriction enzyme treatment of genome DNA.

DNA Primers↗

A computational framework for optimal masking in the synthesis of oligonucleotide microarrays.

High-throughput genomic technologies are revolutionizing modern biology. In particular, DNA microarrays have become one of the most powerful tools for profiling global mRNA expression in different tissues and environmental conditions, and for detecting single nucleotide polymorphisms. The broad applicability of gene expression profiling to the biological and medical realms has generated expanding demand for mass production of microarrays, which in turn has created considerable interest in improving the cost effectiveness of microarray fabrication techniques. We have developed the computational framework for an optimal synthesis strategy for oligonucleotide microarrays. The problem was introduced by Hubbell et al. Here, we formalize the problem, obtain precise bounds on its complexity and devise several computational solutions.

Algorithms↗

Optimized in situ construction of oligomers on an array surface.

Oligonucleotide arrays are powerful tools to study changes in gene expression for whole genomes. These arrays can be synthesized by adapting photolithographic techniques used in microelectronics. Using this method, oligonucleotides are built base by base directly on the array surface by numerous cycles of photodeprotection and nucleotide addition. In this paper we examine strategies to reduce the number of synthesis cycles required to construct oligonucleotide arrays. By computer modeling oligonucleotide synthesis, we found that the number of required synthesis cycles could be significantly reduced by focusing upon how oligonucleotides are chosen from within genes and upon the order in which nucleotides are deposited on the array. The methods described here could provide a more efficient strategy to produce oligonucleotide arrays.

Computer Simulation↗

Light-directed 5'-->3' synthesis of complex oligonucleotide microarrays.

Light-directed synthesis of high-density microarrays is currently performed in the 3'-->5' direction due to constraints in existing synthesis chemistry. This results in the probes being unavailable for many common types of enzymatic modification. Arrays that are synthesized in the 5'-->3' direction could be utilized to perform parallel genotyping and resequencing directly on the array surface, dramatically increasing the throughput and reducing the cost relative to existing techniques. In this report we demonstrate the use of photoprotected phosphoramidite monomers for light-directed array synthesis in the 5'-->3' direction, using maskless array synthesis technology. These arrays have a dynamic range of >2.5 orders of magnitude, sensitivity below 1 pM and a coefficient of variance of <10% across the array surface. Arrays containing >150,000 probe sequences were hybridized to labeled mouse cRNA producing highly concordant data (average R(2) = 0.998). We have also shown that the 3' ends of array probes are available for sequence-specific primer extension and ligation reactions.

Molecular Structure↗

Impact of surface chemistry and blocking strategies on DNA microarrays.

The surfaces and immobilization chemistries of DNA microarrays are the foundation for high quality gene expression data. Four surface modification chemistries, poly-L-lysine (PLL), 3-glycidoxypropyltrimethoxysilane (GPS), DAB-AM-poly(propyleminime hexadecaamine) dendrimer (DAB) and 3-aminopropyltrimethoxysilane (APS), were evaluated using cDNA and oligonucleotide sub-arrays. Two un-silanized glass surfaces, RCA-cleaned and immersed in Tris-EDTA buffer were also studied. DNA on amine-modified surfaces was fixed by UV (90 mJ/cm(2)), while DNA on GPS-modified surfaces was immobilized by covalent coupling. Arrays were blocked with either succinic anhydride (SA), bovine serum albumin (BSA) or left unblocked prior to hybridization with labeled PCR product. Quality factors evaluated were surface affinity for cDNA versus oligonucleotides, spot and background intensity, spotting concentration and blocking chemistry. Contact angle measurements and atomic force microscopy were preformed to characterize surface wettability and morphology. The GPS surface exhibited the lowest background intensity regardless of blocking method. Blocking the arrays did not affect raw spot intensity, but affected background intensity on amine surfaces, BSA blocking being the lowest. Oligonucleotides and cDNA on unblocked GPS-modified slides gave the best signal (spot-to-background intensity ratio). Under the conditions evaluated, the unblocked GPS surface along with amine covalent coupling was the most appropriate for both cDNA and oligonucleotide microarrays.

DNA, Complementary↗

A microarray-based high throughput molecular marker genotyping method: the tagged microarray marker (TAM) approach.

A microarray-based method has been developed for scoring thousands of DNAs for a co-dominant molecular marker on a glass slide. The approach was developed to detect insertional polymorphism of transposons and works well with single nucleotide polymorphism (SNP) markers. Biotin- terminated allele-specific PCR products are spotted unpurified onto streptavidin-coated glass slides and visualised by hybridisation of fluorescent detector oligonucleotides to tags attached to the allele- specific PCR primers. Two tagged primer oligonucleotides are used per locus and each tag is detected by hybridisation to a concatameric DNA probe labelled with multiple fluorochromes.

Biotinylation↗

Functionalization of poly(methyl methacrylate) (PMMA) as a substrate for DNA microarrays.

A chemical procedure was developed to functionalize poly(methyl methacrylate) (PMMA) substrates. PMMA is reacted with hexamethylene diamine to yield an aminated surface for immobilizing DNA in microarrays. The density of primary NH2 groups was 0.29 nmol/cm2. The availability of these primary amines was confirmed by the immobilization of DNA probes and hybridization with a complementary DNA strand. The hybridization signal and the hybridization efficiency of the chemically aminated PMMA slides were comparable to the hybridization signal and the hybridization efficiency obtained from differently chemically modified PMMA slides, silanized glass, commercial silylated glass and commercial plastic Euray trade mark slides. Immobilized and hybridized densities of 10 and 0.75 pmol/cm2, respectively, were observed for microarrays on chemically aminated PMMA. The immobilized probes were heat stable since the hybridization performance of microarrays subjected to 20 PCR heat cycles was only reduced by 4%. In conclusion, this new strategy to modify PMMA provides a robust procedure to immobilize DNA, which is a very useful substrate for fabricating single use diagnostics devices with integrated functions, like sample preparation, treatment and detection using microfabrication and microelectronic techniques.

Base Sequence↗

Construction of oligonucleotide arrays on a glass surface using a heterobifunctional reagent, N-(2-trifluoroethanesulfonatoethyl)-N-(methyl)-triethoxysilylpropyl-3-amine (NTMTA).

A rapid method for construction of oligonucleotide arrays on a glass surface, using a novel heterobifunctional reagent, N-(2-trifluoroethanesulfonatoethyl)-N-(methyl)-triethoxysilylpropyl-3-amine (NTMTA), has been described. The heterobifunctional reagent, NTMTA, carries two different thermoreactive groups. The triethoxysilyl group on one end is specific towards silanol functions on the virgin glass surface, while the trifluoroethanesulfonyl (tresyl) group on the other end of the reagent reacts specifically with aminoalkyl- or mercaptoalkyl- functionalized oligonucleotides. Immobilization of oligonucleotides on a glass surface has been realized via two routes. In the first one (A), 5'- aminoalkyl- or mercaptoalkyl-functionalized oligonucleotides were allowed to react with NTMTA to form a oligonucleotide-triethoxysilyl conjugate which, in a subsequent reaction with unmodified (virgin) glass microslide, results in surface-bound oligonucleotides. In the second route (B), the NTMTA reagent reacts first with a glass microslide whereby it generates trifluoroethanesulfonate ester functions on it, which in a subsequent step react with 5'-aminoalkyl or mercaptoalkyl oligonucleotides to generate support-bound oligonucleotides. Subsequently, the oligonucleotide arrays prepared by both routes were analyzed by hybridization experiments with complementary oligonucleotides. The constructed microarrays were successfully used in single and multiple nucleotide mismatch detection by hybridizing these with fluorescein-labeled complementary oligonucleotides. Further more, the proposed method was compared with the existing methods with respect to immobilization efficiency of oligonucleotides.

Base Pair Mismatch↗

A microarray configuration to quantify expression levels and relative abundance of splice variants.

Over the past decade, alternative RNA splicing has raised a great interest appearing to be of high importance in the generation of expression diversity. This regulatory process plays a critical role in the normal development and its impact on the initiation and development of human disorders as well as on the pharmacological properties of drugs is increasingly being recognized. Only few studies describe specific alternative splicing expression profiling. Microarray strategies have been conceived to address alternative splicing events but with very few experimental data related to their abilities to provide true quantification values. We have developed a specific microarray configuration relying on a few, well optimized probes per splice event. Basically, five probes of 24mer are used to fully characterize a splice event. These probes are of two types, exon probes and junction probes, and are either specific to a splice event or not. The performances of such a 'splice array' were validated on synthetic model systems and on complex biological materials. The results indicate that DNA chips based on this design combining exon and junction derived probes enable the detection and, absolute and relative quantification of splice variants. In addition, this strategy is compatible with all the microarrays that use oligonucleotide probes.

Alternative Splicing↗

Diagnostic application of padlock probes--multiplex detection of plant pathogens using universal microarrays.

Padlock probes (PLPs) are long oligonucleotides, whose ends are complementary to adjacent target sequences. Upon hybridization to the target, the two ends are brought into contact, allowing PLP circularization by ligation. PLPs provide extremely specific target recognition, which is followed by universal amplification and microarray detection. Since target recognition is separated from downstream processing, PLPs enable the development of flexible and extendable diagnostic systems, targeting diverse organisms. To adapt padlock technology for diagnostic purposes, we optimized PLP design to ensure high specificity and eliminating ligation on non-target sequences under real-world assay conditions. We designed and tested 11 PLPs to target various plant pathogens at the genus, species and subspecies levels, and developed a prototype PLP-based plant health chip. Excellent specificity was demonstrated toward the target organisms. Assay background was determined for each hybridization using a no-target reference sample, which provided reliable and sensitive identification of positive samples. A sensitivity of 5 pg genomic DNA and a dynamic range of detection of 100 were observed. The developed multiplex diagnostic system was validated using genomic DNAs of characterized isolates and artificial mixtures thereof. The demonstrated system is adaptable to a wide variety of applications ranging from pest management to environmental microbiology.

Animals↗

Multiplex amplification enabled by selective circularization of large sets of genomic DNA fragments.

We present a method to specifically select large sets of DNA sequences for parallel amplification by PCR using target-specific oligonucleotide constructs, so-called selectors. The selectors are oligonucleotide duplexes with single-stranded target-complementary end-sequences that are linked by a general sequence motif. In the selection process, a pool of selectors is combined with denatured restriction digested DNA. Each selector hybridizes to its respective target, forming individual circular complexes that are covalently closed by enzymatic ligation. Non-circularized fragments are removed by exonucleolysis, enriching for the selected fragments. The general sequence that is introduced into the circularized fragments allows them to be amplified in parallel using a universal primer pair. The procedure avoids amplification artifacts associated with conventional multiplex PCR where two primers are used for each target, thereby reducing the number of amplification reactions needed for investigating large sets of DNA sequences. We demonstrate the specificity, reproducibility and flexibility of this process by performing a 96-plex amplification of an arbitrary set of specific DNA sequences, followed by hybridization to a cDNA microarray. Eighty-nine percent of the selectors generated PCR products that hybridized to the expected positions on the array, while little or no amplification artifacts were observed.

Base Sequence↗

In situ oligonucleotide synthesis on poly(dimethylsiloxane): a flexible substrate for microarray fabrication.

In this paper, we demonstrate in situ synthesis of oligonucleotide probes on poly(dimethylsiloxane) (PDMS) microchannels through use of conventional phosphoramidite chemistry. PDMS polymer was moulded into a series of microchannels using standard soft lithography (micro-moulding), with dimensions <100 microm. The surface of the PDMS was derivatized by exposure to ultraviolet/ozone followed by vapour phase deposition of glycidoxypropyltrimethoxysilane and reaction with poly(ethylene glycol) spacer, resulting in a reactive surface for oligonucleotide coupling. High, reproducible yields were achieved for both 6mer and 21mer probes as assessed by hybridization to fluorescent oligonucleotides. Oligonucleotide surface density was comparable with that obtained on glass substrates. These results suggest PDMS as a stable and flexible alternative to glass as a suitable substrate in the fabrication and synthesis of DNA microarrays.

Dimethylpolysiloxanes↗

Molecular beacons with a homo-DNA stem: improving target selectivity.

Molecular beacons (MBs) are stem-loop DNA probes used for identifying and reporting the presence and localization of nucleic acid targets in vitro and in vivo via target-dependent dequenching of fluorescence. A drawback of conventional MB design is present in the stem sequence that is necessary to keep the MBs in a closed conformation in the absence of a target, but that can participate in target binding in the open (target-on) conformation, giving rise to the possibility of false-positive results. In order to circumvent these problems, we designed MBs in which the stem was replaced by an orthogonal DNA analog that does not cross-pair with natural nucleic acids. Homo-DNA seemed to be specially suited, as it forms stable adenine-adenine base pairs of the reversed Hoogsteen type, potentially reducing the number of necessary building blocks for stem design to one. We found that MBs in which the stem part was replaced by homo-adenylate residues can easily be synthesized using conventional automated DNA synthesis. As conventional MBs, such hybrid MBs show cooperative hairpin to coil transitions in the absence of a DNA target, indicating stable homo-DNA base pair formation in the closed conformation. Furthermore, our results show that the homo-adenylate stem is excluded from DNA target binding, which leads to a significant increase in target binding selectivity.

Base Pairing↗

Using a microfluidic device for 1 microl DNA microarray hybridization in 500 s.

This work describes a novel and simple modification of the current microarray format. It reduces the sample/reagent volume to 1 microl and the hybridization time to 500 s. Both 20mer and 80mer oligonucleotide probes and singly labeled 20mer and 80mer targets, representative of the T-cell acute lymphocytic leukemia 1 (TAL1) gene, have been used to elucidate the performance of this hybridization approach. In this format, called shuttle hybridization, a conventional flat glass DNA microarray is integrated with a PMMA microfluidic chip to reduce the sample and reagent consumption to 1/100 of that associated with the conventional format. A serpentine microtrench is designed and fabricated on a PMMA chip using a widely available CO2 laser scriber. The trench spacing is compatible with the inter-spot distance in standard microarrays. The microtrench chip and microarray chip are easily aligned and assembled manually so that the microarray is integrated with a microfluidic channel. Discrete sample plugs are employed in the microchannel for hybridization. Flowing through the microchannel with alternating depths and widths scrambles continuous sample plug into discrete short plugs. These plugs are shuttled back and forth along the channel, sweeping over microarray probes while re-circulation mixing occurs inside the plugs. Integrating the microarrays into the microfluidic channel reduces the DNA-DNA hybridization time from 18 h to 500 s. Additionally, the enhancement of DNA hybridization reaction by the microfluidic device is investigated by determining the coefficient of variation (CV), the growth rate of the hybridization signal and the ability to discriminate single-base mismatch. Detection limit of 19 amol was obtained for shuttle hybridization. A 1 mul target was used to hybridize with an array that can hold 5000 probes.

Basic Helix-Loop-Helix Proteins↗

Cell-type-specific transcriptomics in chimeric models using transcriptome-based masks.

Regulatory networks involving different cell types control inflammation, morphogenesis and tissue homeostasis. Cell-type-specific transcriptional profiling offers a powerful tool for analyzing such cross-talk but is often hampered by mingling of cells within a tissue. Here, we present a novel method that performs cell-type-specific expression measurements without prior cell separation. This involves inter-species transplantation or chimeric co-culture models among which the human mouse system is frequently used. Here, we exploit the sufficiently divergent transcriptomes of human and mouse in conjunction with high-density oligonucleotide arrays. This required a masking procedure based on transcriptome databases and exhaustive fuzzy mapping of oligonucleotide probes onto these data. The approach was tested in a human-mouse experiment, demonstrating that we can efficiently measure species-specific transcriptional profiles in chimeric RNA samples without physically separating cells. Our results stress the importance of transcriptome databases with accurate 3' mRNA termination for computational prediction of accurate probe masks. We find that most human and mouse 3'-untranslated region contain unique stretches to allow for an effective control of cross-hybridization between the two species. This approach can be applied to xenograft models studying tumor-host interactions, morphogenesis or immune responses.

Animals↗

DNA microarrays on nanoscale-controlled surface.

We have developed new surface to ensure a proper spacing between immobilized biomolecules. While DNA microarray on this surface provided each probe DNA with ample space for hybridization with incoming target DNAs, the microarray showed enhanced discrimination efficiency for various types of single nucleotide polymorphism. The high discrimination efficiency holds for all tested cases (100:<1 for internal mismatched cases; 100:<28 for terminal mismatched ones). In addition, by investigating influence of hybridization temperature and washing condition on the fluorescence intensity and the discrimination efficiency with and without controlled mesospacing, it was observed that the nanoscale-controlled surface showed good discrimination efficiency in a wide range of temperature (37-50 degrees C), and hybridization behavior on the surface was in agreement with the solution one. Intriguingly, it was found that washing process after the hybridization was critical for the high discrimination efficiency. For the particular case, washing process was so efficient that only 30 s washing was sufficient to reach the optimal discrimination ratio.

Anthracenes↗

Electrochemically directed synthesis of oligonucleotides for DNA microarray fabrication.

We demonstrate a new method for making oligonucleotide microarrays by synthesis in situ. The method uses conventional DNA synthesis chemistry with an electrochemical deblocking step. Acid is delivered to specific regions on a glass slide, thus allowing nucleotide addition only at chosen sites. The acid is produced by electrochemical oxidation controlled by an array of independent microelectrodes. Deblocking is complete in a few seconds, when competing side-product reactions are minimal. We demonstrate the successful synthesis of 17mers and discrimination of single base pair mismatched hybrids. Features generated in this study are 40 mum wide, with sharply defined edges. The synthetic technique may be applicable to fabrication of other molecular arrays.

Acids↗