Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compomers”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Effects of aging on repair of resin-modified glass-ionomer cements.

The effects of aging on the repair bond strengths of resin-modified glass-ionomer cements after different methods of surface conditioning were studied. Surface conditioning methods included the following: maleic acid; maleic acid with resin application; polyacrylic acid; polyacrylic acid with resin application. Shear bond testing between the aged and new material was carried out with an Instron Universal testing machine. Surface conditioning with maleic acid and resin application gave the highest repair bond strengths at 3 and 6 months. There was, however, no statistically significant difference in bond strengths between the different treatment groups after both 3 and 6 months storage. Intergroup comparisons revealed no significant difference in failure modes after both storage periods. For all treatment groups, no significant difference in repair bond strengths was noted between storage after 1 week, 3 and 6 months. There appears to be a general decrease in repair bond strengths for all treatment groups after 3 months storage. The clinical repair of resin-modified glass-ionomer cements after this period of time is therefore not recommended.

Acid Etching, Dental↗

Morphological interface between hybrid ionomers and dentin with and without smear-layer removal.

To evaluate the micromorphological interface between dentin and several hybrid ionomer restoratives, a flat dentin surface was obtained on the occlusal surfaces of extracted human molar teeth after sectioning the enamel with an Isomet saw. Three poly-acid-modified composite resins, Compoglass, Dyract and F2000, and two resin-modified glass-ionomer cements, Fuji II LC and Photac-Fil were applied to the dentin surface. A second section, 2 mm apical from the first one, was made to produce a dentin segment containing the tested materials. Each disc was then split fractured along the dentin/material interface. For the poly-acid-modified composites, one half of the disc was stored in 6 mol/L HCl for 48 h to remove the dentin. The other was gently decalcified and deprotenized at the interface between the hybrid ionomer and the dentin. Both halves were then sputtered with gold and examined using SEM. For resin-modified glass-ionomer, samples were only evaluated at the interface. The three poly-acid-modified composite resins showed the formation of hybrid layers and resin tags at the interface to the dentin. Removal of the smear layer significantly improves hybridization of these materials. Also, Fuji II LC produced a hybrid layer while the Photac-Fil showed no evidence of hybridization.

Compomers↗

Antibacterial properties of dentin bonding systems, polyacid-modified composite resins and composite resins.

This study examined the antibacterial activities of the bonding systems Syntac, EBS and Scotchbond 1, the polyacid-modified composite resins Hytac and Compoglass, and the composite resins Tetric, Z100 and Scalp-it. They were evaluated using the cariogenic bacteria Streptococcus mutans, Lactobacillus salivarius, Streptococcus sorbinus and Actinomyces viscosus in vitro with a modified cylinder drop plate agar diffusion assay. All adhesives of the dentin bonding systems and the polyacid-modified composite resins exhibited various degrees of antibacterial activity against all of the test bacteria. On the contrary, composite resins did not affect bacterial growth. The data suggest that the use of these adhesives and polyacid-modified composite resins may reduce the consequences of microleakage owing to their antibacterial properties.

Actinomyces viscosus↗

Direct tensile strength of visible light-cured restorative materials containing fluoride.

The purpose of this study was to compare the fluoride release and direct tensile strength at 24 h, 1 month, and 3 months of two conventional glass-ionomers, two visible light-cured resin-modified glass-ionomers, a polyacid resin composite and two resin composites. The results were statistically analysed using ANOVA and Fisher's PLSD at alpha=0.05. The data on fluoride release indicated that the immersion period (24 h, 1 month, and 3 months) significantly influenced the cumulative amount of fluoride released (P < 0.001). The direct tensile strengths after 1 month of storage were significantly higher than those after 24 h or 3 months of storage (P < 0.001). Thus, the cements and resins were not weakened by the loss of fluoride. Conventional glass-ionomer cement showed the lowest direct tensile strength. Resin-modified glass-ionomer behaved in between the resin composites and conventional glass-ionomers in terms of all three testing times, however, the polyacid resin composites most closely resembled the resin composites. The polyacid resin composites had greatly enhanced direct tensile strength, however, this material also reduced the fluoride availability.

Compomers↗

Effect of curing with a plasma light on the properties of polymerizable dental restorative materials.

Specimens of light-curable dental restoratives have been prepared using either a conventional dental curing lamp (for 20 or 30 s) or a plasma light (for 1 or 2 s). The specimens were then stored in water until their mass equilibrated, then dried to constant mass. Most specimens lost material in this process but the losses in all specimens cured with the plasma light were significantly greater than those cured with the conventional lights (P < 0.05). Longer cure times gave slightly reduced losses in water in most cases. The specimens were then returned to water and allowed to re-equilibrate and their equilibrium water uptake determined. There was no simple trend in this latter property because elution of loosely bound hydrophilic species may have resulted in a less hydrophilic specimen, whose equilibrium water content was therefore correspondingly lower. Overall, the losses through dissolution in water suggest that plasma curing is less effective for these materials than conventional light curing, as it probably results in material with lower molar mass. The losses for the resin-modified glass-ionomer were much greater than for other materials, and it was concluded that the more rapid polymerization with plasma light caused a significant inhibitation of the acid-base part of the setting process. These findings suggest that long-term durability of materials may be compromised by employing plasma light cure rather than a conventional cure system and further studies of this point are recommended.

Acids↗

Colour reproducibility of a photo-activated prosthetic composite with different thicknesses.

This study determined the colour accuracy of a photo-activated prosthetic composite with various thicknesses and shades for the purpose of evaluating the relationship between material thickness variation and colour reproducibility. Four light shades (A1, B1, C1 and D2) and four dark shades (A4, B4, C4 and D4) of a representative photo-activated prosthetic composite (Artglass) for body paste were assessed. The specimens were prepared with thicknesses of 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 mm. The L*a*b* colour parameter of each shade was measured using a dental colorimeter (ShadeEye) connected to a computer. The overall colour accuracy of groups of five specimens was compared by means of analysis of variance (ANOVA) and Scheffe's S multiple range test (P=0;05). In addition, L*a*b* colour difference (Delta E*) values between the 3.0 mm thickness and the other thicknesses were calculated. Three-factor ANOVA revealed that all colour parameters were influenced by the thickness as well as by the shade letter and shade tab (P < 0.05). The L* value consistently decreased for all shades as thickness increased, although there was no obvious correlation between the thickness of the material and either the a* or b* values. Among the Delta E* values, the values between the 2.5 and 3.0 mm thicknesses were the lowest, and values were found to be lower than 2.0 for all shades. The colour accuracy of the photo-activated prosthetic composite was related to the thickness of the material regardless of the shade. For acceptable colour reproducibility, a composite material thickness of at least 2.5 mm was found to be required.

Color↗

In vitro cytotoxicity of six dentin bonding agents.

The cytotoxicity of six dentin bonding agents (Syntac, Solobond, Bond 1, Scotchbond 1, Heliobond and F-2000) was tested against an established cell line, L929. Under aseptic conditions 3, 5 and 10 microL dentin bonding agents were placed in the centre of Petri dishes. Each dish was covered with a 5-mL suspension of fibroblasts at a concentration of 40 000 cells mL(-1). The cultures were incubated at 37 degrees C and cytotoxicity was assessed by a quantitative technique at 24 and 72 h. All the dentin bonding agents were found to be cytotoxic. Scotchbond 1 and F-2000 showed the highest cytotoxicity followed by Solobond and Bond 1. Heliobond and Syntac were the least toxic materials.

Acrylates↗

Fluoride release and uptake characteristics of aesthetic restorative materials.

The aims of this study were firstly to investigate the fluoride-releasing characteristics of two composite resins (Tetric and Valux Plus), two polyacid-modified resin composites (Compoglass and Dyract), and conventional glass-ionomer cement (Ceramfil beta). The second aim was to assess the fluoride uptake and subsequent release from the same range of materials. Fifteen discs (6 mm diameter and 1.5 mm height) were prepared for each material. Each disc was immersed in 4 ML of deionized water within a plastic vial. The release of fluoride was measured daily at 1, 2, 3, 4, 5, 15, 30 and 60 days. After daily fluoride release was measured for 60 days, samples were refluoridated in 1000-ppm sodium fluoride (NaF) solutions (pH 6.6) for 10 min and fluoride release was measured daily for a total of 5 days. The release of fluoride from aesthetic restorative materials was measured by using specific fluoride electrode and an ionanalyser. Results were statistically analysed by two-way repeated measure ANOVA and Duncan's multiple range test. The results revealed that all fluoride-containing materials (Ceramfil beta, Compoglass, Dyract, Tetric) released fluoride initially and the release was greatest at the first day. At any time during the test period Ceramfil beta released the most and Valux Plus did not release any detectable fluoride (P < 0.01). Sample exposures to 1000 ppm NaF solution increased the 24-h fluoride release from all fluoride-containing materials. This difference lasted only 24-48 h after exposure. Ceramfil beta had a tendency to recharge not seen with the other materials (P < 0.05).

Analysis of Variance↗

Effect of storage media upon the surface micromorphology of resin-based restorative materials.

The aim of this study was to evaluate the effect of different storage media upon the surface micromorphology of resin-based restoratives. One resin-modified glass-ionomer (Fuji II LC Improved), one polyacid-modified composite resin (Dyract AP), one microfilled composite resin (Durafill VS), and one hybrid composite resin (Filtek Z250) were tested. For each material, 45 standardized cylindrical specimens were randomly made. After 24 h, samples were finished and polished, and their surface roughness measured to obtain Ra (micro m) baseline values (Bv). Fifteen specimens of each material were then stored at 37 +/- 1 degrees C, for 24 h, either in distilled deionized water or in artificial saliva, or else subjected to a pH-cycling regimen. At the end of 10 days of storage, final readings (Fv) of surface roughness were obtained. The Analysis of Covariance (alpha=0.05), considering the covariate Bv showed a significant interaction between restorative materials and storage media (P value=0.0000). Multiple comparison Tukey's test revealed that the surface roughness of resin-based restoratives subjected to a pH-cycling model was significantly higher compared with both distilled deionized water and artificial saliva. Micromorphological changes were noticed in a situation of acid challenge.

Acids↗

Marginal gap formation of composites in dentine: effect of water storage.

This study investigated the effects of water storage on the marginal adaptation of two composite resins (Spectrum TPH and Ariston AT), two polyacid-modified composite resins (Dyract AP and F2000) and a new PRG composite (Reactmer) to dentine over time. Two cylindrical dentine cavities (1.5 mm diameter and 1.5 mm deep) were prepared on the horizontally sectioned surfaces of freshly extracted teeth. In each tooth, one cavity was restored using composites with their respective bonding system and the other without the bonding system. The sample size for each material with/without bonding system was 6. The composites were placed in one increment, bulk-polymerized, immediately finished/polished with the Sof-lex discs system and fine polished on 30 microm silicon carbide/9 microm aluminium oxide lapping film discs in a microgrinding system. The specimens were then stored in distilled water at 37 degrees C and the maximum marginal gap width between the material and the dentine wall was determined at 24 h, 1 week, 2 weeks, 3 weeks and 4 weeks using a measurescope at x500 magnification. Results were subjected to statistical analysis using monva, anova/Scheffe's post hoc test and independent samples of t-test at significance level 0.05. At all time intervals, no significant difference in marginal gap formation was observed between materials. Where bonding systems were not used, a decrease in gap widths over time was observed with most materials but only Dyract AP exhibited a significant decrease. The latter was observed after 2 weeks storage in water. The use of bonding systems reduced dentine marginal gaps significantly and is therefore mandatory for all composites evaluated. Marginal gaps arising from polymerization contraction of conventional, polyacid-modified and PRG composites cannot be fully compensated by hydroscopic expansion. Clinical relevance Bonding systems are mandatory for all composites when bonding to dentin. In the event of a bond failure at placement, hygroscopic expansion of composites can reduce marginal gaps but not completely.

Compomers↗

Cellular reactions to polylactide-based sponge and collagen gel in subcutaneous tissue.

Polylactide copolymer and collagen are now used as bio-absorbable scaffold materials for restoration of lost oral tissues. Polylactide caprolactone (PLCL) sponge and collagen gel were examined for their cellular reactions when implanted in 8-week-old Sprague-Dawley (SD) rats' subcutaneous tissues for up to 8 weeks. The PLCL sponges were slowly absorbed by a mild chronic inflammation process in which multinucleated giant cells covered and slowly captivated the sponge surfaces without thick encapsulation. On the other hand, collagen gel was surrounded by thick inflammatory reaction zones and infiltrated by acute inflammation cells including neutrophils, lymphocytes and macrophages, and disappeared more rapidly. Although the bio-absorption process differed, both materials, when combined, appear to be useful scaffold materials for tissue engineering therapy in future dental practice.

Absorbable Implants↗

The effect of saliva on shear bond strengths of hydrophilic bonding systems.

Failure of orthodontic bonded attachments and brackets is mostly attributed to contamination of the enamel surface. To overcome this problem, materials have been developed that purportedly overcome the moisture and contaminants present in the oral environment. This study compared the shear bond strengths of 2 lightcured hydrophilic bonding systems, Transbond XT with MIP (3M/Unitek, Monrovia, Calif) and Assure (Reliance Orthodontics, Itasca, Ill) with a hydrophobic bonding system, Transbond XT with XT primer (3M/Unitek). Comparison tests were conducted under 4 enamel surface conditions: (1) etched and dried; (2) etched and moistened with artificial saliva; (3) etched, primed, and moistened with artificial saliva; and (4) etched, primed, moistened with artificial saliva, and reprimed. In addition, an adhesive remnant index score was used to determine the amount of adhesive remaining on the tooth. Stainless steel brackets with mesh-backed pads (n = 144) were bonded to bovine teeth. Bond strength was then tested in shear using an Instron mechanical testing instrument. There were significant differences in the bond strengths among the products (P <.05), within surface treatments (P <.05), and among the different bonding materials in combination with various surface treatments (P <.05). Treatments 1 and 4 showed the highest mean bond strengths adhesive remnant index scores, whereas treatments 2 and 3 showed the lowest mean bond strengths and scores.

Acid Etching, Dental↗

Comparison of bond strength of three adhesives: composite resin, hybrid GIC, and glass-filled GIC.

The objective of this study was to compare 3 orthodontic adhesives in the areas of shear-peel bond strength, location of adhesive failure, and extent of enamel cracking before bonding and after debonding of orthodontic brackets. The adhesives included a composite resin control (Transbond XT; 3M/Unitek, St Paul, Minn), a resin-modified glass ionomer cement (Fuji Ortho LC; GC America Corp, Alsip, Ill), and a polyacid-modified composite resin under dry and saliva-contaminated conditions (Assure; Reliance Orthodontic Products Inc, Itasca, Ill). Metal brackets were bonded to the buccal surfaces of 160 (4 groups of 40) human premolars. The bonded teeth were stored in deionized water at 37 degrees C for 30 days and thermocycled for 24 hours before debonding with a Universal Instron (Instron Corp, Canton, Mass) testing machine. The extent of cracking in the buccal surfaces was evaluated under 16x magnification before bonding and after debonding. Although the bond strength of the composite resin control (20.19 MPa) was significantly greater (P <.05) than that of the adhesives in the other groups, clinically acceptable shear-peel bond strengths were found for all adhesives (Fuji Ortho LC = 13.57 MPa, Assure-dry = 10.74 MPa, Assure-wet = 10.99 MPa). The bond strength for the Assure adhesive was not significantly affected by saliva contamination. The sample of extracted premolars used in this study displayed a greater frequency of buccal surface enamel cracking (46.7%) than that reported in the literature for in vivo premolars (7.8%-10.2%), which was possibly due to the extraction process. The frequency of enamel cracking in a subset of this sample (n = 34) increased from 46.4% at prebonding to 62.4% at postdebonding as a result of the forces of debonding.

Acid Etching, Dental↗

A comparison of fluoride release by resin-modified GIC and polyacid-modified composite resin.

The objective of this study was to compare the fluoride release of 2 fluoride-containing orthodontic adhesives from bracketed teeth and adhesive disks, a resin-modified glass ionomer cement (Fuji Ortho LC, encapsulated; GC America Corp, Aslip, Ill) and a polyacid-modified composite resin (Assure; Reliance Orthodontic Products, Itasca, Ill). A composite resin without fluoride (Transbond XT; 3M Unitek, Monrovia, Calif) was used as a reference control. Metal brackets were bonded to the buccal surfaces of 120 human premolars (40 teeth per adhesive), and disks were made from each adhesive. The deionized storage water was changed, and fluoride release was measured at specified intervals up to 28 days for the bracketed teeth and up to 150 days for the disks. Fuji Ortho LC released 75% more accumulated fluoride than Assure (6.61 microg/bracket vs 3.77 microg/bracket) from bracketed teeth over the 28-day observation period. Assure released more fluoride per day than did Fuji Ortho LC from the disks during the first 3 months. For the rest of the 150-day period, Fuji Ortho LC released more fluoride per day than did Assure. The amount of fluoride released by these materials varied dramatically with different water-changing protocols. The large discrepancy between fluoride released from disks compared with that released from bracketed teeth suggests that caution must be used in extrapolating fluoride-release levels of adhesive disks to in vivo treatment conditions.

Acrylic Resins↗

A review of orthodontic cements and adhesives.

Dental cements and resins are used intraorally to secure fixed orthodontic devices. Although cements are still used, the popularity of resin and resin-cement hybrid materials is increasing because of their improved physical properties and low solubility in oral fluids. Some cements bond chemically to enamel, but bond strengths are low because cements are brittle and fracture cohesively. Resin adhesives penetrate micropores in etched enamel and mechanical retentions in orthodontic devices, resulting in higher bond strengths because resins are more fracture resistant than cements. Resins, however, do not bond well in the presence of moisture, and their attachment to surfaces is primarily mechanical. Hybridized materials combine the advantages of cements and resins but also have certain disadvantages. Optimal material selection and application require an understanding of the chemical differences and physical limitations of today's orthodontic cements, resins, and hybrid materials.

Acid Etching, Dental↗

Fluoride release from new light-cured orthodontic bonding agents.

The purpose of this study was to compare the rates of fluoride release with time from 1 nonfluoridated and 3 fluoride-containing orthodontic bonding materials in distilled water and artificial saliva. Materials tested were Assure (Reliance Orthodontic Products, Itasca, Ill), Fuji Ortho LC (GC, Tokyo, Japan), Python (TP Orthodontics, LaPorte, Ind), and Transbond XT (3M Dental Products, Monrovia, Calif). Ten specimens of each material type were stored in distilled water, and 10 of each type were stored in artificial saliva at 37 degrees C. Fluoride release was measured with an ion-specific electrode. Readings were taken periodically for a total time period of 6 months. At day 1, Assure released the most fluoride into distilled water (66.2 microg/cm(2)) and into artificial saliva (65.8 microg/cm(2)), followed by Fuji Ortho LC (25.9 microg/cm(2); 18.8 microg/cm(2)), Python (6.3 microg/cm(2); 4.2 microg/cm(2)), and Transbond (0.1 microg/cm(2); 0.1 microg/cm(2)). The fluoride release rates were highest during the first days of testing, declining to lower but more stable levels. At the end of 6 months, Fuji Ortho LC released the most fluoride (3.8 microg/cm(2); 3.5 microg/cm(2)) followed by Assure (3.1 microg/cm(2); 2.8 microg/cm(2)), Python (2.6 microg/cm(2); 1.7 microg/cm(2)), and Transbond (0.1 microg/cm(2); 0.1 microg/cm(2)). The type of storage medium did not dramatically affect fluoride release. The second part of the study, undertaken after a year of sample storage, tested the 20 samples of Assure for a further 2-week period, after exposure to running and still distilled water. Although fluoride release rates declined with time, they were still higher than the 1.5 microg/cm(2) level that is referenced as inhibiting decalcification of enamel in a clinical environment. Release rates were similar in running and still water at all time points. Throughout the 6-month period, all 3 fluoride-containing materials had rates of fluoride release that could theoretically inhibit decalcification of enamel.

Acrylic Resins↗

Comparison of fluoride release protocols for in-vitro testing of 3 orthodontic adhesives.

The objective of this study was to compare the fluoride release of 3 orthodontic adhesives using disks and bracketed teeth with different storage protocols. The adhesives used were a resin-modified glass ionomer (RMGI) (Fuji Ortho LC; GC America, Aslip, Ill), a polyacid-modified composite resin (PMCR)(Assure; Reliance Orthodontic Products, Itasca, Ill), and a composite control, Transbond XT (3M Unitek, Monrovia, Calif). Metal brackets were bonded to the buccal and lingual surfaces of 120 extracted human premolars. Five plastic containers holding 4 teeth (8 brackets) were used for each adhesive protocol. The samples were stored in containers holding 4 mL of deionized water at 37 degrees C for 28 and 84 days for the brackets and disks, respectively. The bracketed samples released larger initial amounts of fluoride compared with the disk samples during the first 5 to 6 days for both fluoride-releasing adhesives. The PMCR (Assure) released more fluoride (mg/cm(2)/day) than did the RMGI (Fuji Ortho LC) in all protocols with the exception of daily protocols when values diminished below the RMGI values near the 24th day and between the 56th and the 70th days for the bracketed and disk samples, respectively. Inconsistent values for fluoride release were noted in the bracket and disk samples when compared with daily versus cumulative water changes. Daily water changes revealed higher fluoride release levels (brackets), but this trend was not evident in the disk samples. Daily water changes may yield more clinically relevant data on fluoride release.

Acrylic Resins↗

Bond strength comparison of moisture-insensitive primers.

The objective of this in vitro bonding study was to evaluate the effectiveness of 2 moisture-insensitive primers, Assure (Reliance Orthodontic Products, Itasca, Ill) and MIP (3M Unitek, Monrovia, Calif) compared with a control hydrophobic primer, Transbond XT (3M Unitek). Six groups of 40 premolars were acid etched and bonded using metal orthodontic brackets with the following in vitro protocols: (1) Transbond XT primer and adhesive applied to a noncontaminated surface; (2) Assure primer applied after saliva contamination; (3) MIP primer applied after saliva contamination; (4) Assure primer reapplied after saliva contamination; (5) MIP reapplied after saliva contamination; and (6) Assure adhesive applied after saliva contamination of the primer. All bonded specimens were stored in deionized water at 37 degrees C for 30 days and thermocycled for 24 hours before debonding. Brackets were debonded using a shear-peel load on a testing machine, bond strength was measured in megapascals, and bond failure was analyzed by using the adhesive remnant index. In vitro shear-peel bond strengths were acceptable for all groups, and the bond strengths for Assure and MIP were not significantly affected by saliva contamination. The mean shear-peel bond strength of the control (14.82 MPa) was significantly higher (P <.001) than the contaminated groups with the exception of MIP group 5 (14.02 MPa). The values of the Assure primer and adhesive were less than the MIP primer and its respective adhesive; however, the hydrophilic Assure adhesive resin applied to a saliva-contaminated surface had acceptable bond strength. Bond failure analysis (adhesive remnant index) mainly showed adhesive bond failures. An increased frequency of enamel fractures at debond was noted, with the control group (1) and the MIP groups (3 and 5) having 22.5%, 12.5%, and 15%, respectively. The Assure groups had no enamel fractures.

Acid Etching, Dental↗