Shade trees reduce building energy use and CO2 emissions from power plants.

Urban shade trees offer significant benefits in reducing building air-conditioning demand and improving urban air quality by reducing smog. The savings associated with these benefits vary by climate region and can be up to $200 per tree. The cost of planting trees and maintaining them can vary from $10 to $500 per tree. Tree-planting programs can be designed to have lower costs so that they offer potential savings to communities that plant trees. Our calculations suggest that urban trees play a major role in sequestering CO2 and thereby delay global warming. We estimate that a tree planted in Los Angeles avoids the combustion of 18 kg of carbon annually, even though it sequesters only 4.5-11 kg (as it would if growing in a forest). In this sense, one shade tree in Los Angeles is equivalent to three to five forest trees. In a recent analysis for Baton Rouge, Sacramento, and Salt Lake City, we estimated that planting an average of four shade trees per house (each with a top view cross section of 50 m2) would lead to an annual reduction in carbon emissions from power plants of 16,000, 41,000, and 9000 t, respectively (the per-tree reduction in carbon emissions is about 10-11 kg per year). These reductions only account for the direct reduction in the net cooling- and heating-energy use of buildings. Once the impact of the community cooling is included, these savings are increased by at least 25%.

Air Conditioning↗

Effects of aeration during growth of Bacillus stearothermophilus on proton pumping activity and change of terminal oxidases.

The effects of aeration during bacterial growth on the proton translocating activity of the respiratory chain of B. stearothermophilus ATCC 8005, which is stable enough for measurement of the H+/O ratio by an oxygen pulse method, were examined. For endogenous and ascorbate-N,N,N',N'-tetramethyl p-phenylene diamine (TMPD) respiration, H+/O ratios of around 6 and 2 were obtained using resting cells grown under highly aerated conditions. The values were about 4 and 0 when cells were grown under limited-air conditions. Spectrophotometric and enzyme kinetical analyses revealed that both cytochrome caa3 and pigment-432 (cytochrome cao) were acting as terminal oxidases, while cytochrome b-558 (corresponding to the "cytochrome o-type oxidase" of the thermophilic bacterium PS3 in the previous paper [Sone, N., Kutoh, E., & Sato, K. (1990) J. Biochem. 107, 597-602]) was mainly serving in the cells grown under limited-air conditions. Measurement of the pH change upon ferrocytochrome c pulse with proteoliposomes reconstituted from the membrane extract of vigorously aerated cells and that of limited-air cells suggested that both cytochrome caa3, and pigment-432 (cytochrome cao) pump protons, while cytochrome b-558 does not.

Air↗

[Bedroom thermal environment in Nagoya, Japan].

OBJECTIVES: The objective of this study was to estimate the indoor thermal environment and the air-conditioning pattern in bedrooms during sleeping time, and to evaluate the relationship between the indoor thermal environment and the dwelling characteristics in Nagoya, Japan. METHODS: Temperature, relative humidity and information on dwelling characteristics were obtained from 84 dwellings in summer and 100 dwellings in winter from 1995 to 2001. RESULTS: The mean percentage of bedrooms air-conditioned during sleeping time was 23% when cooled in summer and 7% when heated in winter. The mean temperature and relative humidity in bedrooms during sleeping time was 27.7 degrees C and 62% in summer, and 13.1 degrees C and 61% in winter, respectively. The temperatures in bedrooms during sleeping time were found to comply with the recommended values for an indoor thermal environment (24-28 degrees C in summer and 15-21 degrees C in winter) in 39% of the dwellings in summer and 24% of them in winter. The mean temperature in bedrooms during sleeping time was significantly higher in apartments than in separate houses (p < 0.01) in winter, although there was no significant difference of mean temperature between apartments and houses in summer. There was no significant difference in mean relative humidity between apartments and houses in both summer and winter. CONCLUSION: Although the mean temperature in bedrooms during sleeping time varied widely depending on the type of dwelling, there also appeared to be differences between apartments and houses with respect to the temperature in bedrooms during sleeping time in winter.

Air Conditioning↗

[Occupational exposure to enflurane and laughing gas in operating rooms].

Current scientific evidence suggests that chronic exposure to trace concentrations of anaesthetic gases may result in various forms of untoward health responses in operating room personnel. Although there are no clear dose-effect-relationships, in Germany threshold values (MAK-values) exist for nitrous oxide of 100 ppm and for enflurane of 20 ppm. Aim of this investigation was, to determine the exposure of the operating room personnel under modern working conditions using a standardized anaesthetic procedure. By means of a direct-reading, high sensitive gas monitor trace concentrations of nitrous oxide and enflurane were measured at three personnel-related (surgeon, anaesthetist, auxiliary nurse) and a potential leakage source (patient's mouth). The calculation and assessment of the measured concentrations followed the prescriptions of the technical rules for hazardous substances 402 and 403 (TRGS 402 and 403). The personnel-related concentrations were clearly under the MAK-values of 100 ppm nitrous oxide and/or 20 ppm enflurane. The time weighted averages were for the personnel-related measurement points, indicated in ppm for nitrous oxide and enflurane, respectively: "surgeon" 28.3/0.25, "anaesthetist" 39.3/0.34 and "auxiliary nurse" 64.6/0.57. At the leakage source "patient's mouth" time weighted averages of 317 ppm nitrous oxide and 3.79 ppm enflurane were measured. Under air-conditioning with a high air change rate, a central scavenging system and low leakage anaesthesia machine low trace concentrations of anaesthetic gases were measured. Despite an average contamination of approx. 300 ppm nitrous oxide at the "patient's mouth" personnel-related values remained clearly under the MAK-values. Outside the mainstream of the air-conditioning system the group "auxiliary nurse" had an approximately 30% higher exposure than the other groups. Under the described conditions, the working environment "operating room" can be classified as a low exposure working area.

Air Pollutants, Occupational↗

Effects of engine speed and accessory load on idling emissions from heavy-duty diesel truck engines.

A nontrivial portion of heavy-duty vehicle emissions of NOx and particulate matter (PM) occurs during idling. Regulators and the environmental community are interested in curtailing truck idling emissions, but current emissions models do not characterize them accurately, and little quantitative data exist to evaluate the relative effectiveness of various policies. The objectives of this study were to quantify the effect of accessory loading and engine speed on idling emissions from a properly functioning, modern, heavy-duty diesel truck and to compare these results with data from earlier model year vehicles. It was found that emissions during idling varied greatly as a function of engine model year, engine speed, and accessory load conditions. For the 1999 model year Class 8 truck tested, raising the engine speed from 600 to 1050 rpm and turning on the air conditioning resulted in a 2.5-fold increase in NOx emissions in grams per hour, a 2-fold increase in CO2 emissions, and a 5-fold increase in CO emissions while idling. On a grams per gallon fuel basis, NOx emissions while idling were approximately twice as high as those at 55 mph. The CO2 emissions at the two conditions were closer. The NOx emissions from the 1999 truck while idling with air conditioning running were slightly more than those of two 1990 model year trucks under equivalent conditions, and the hydrocarbon (HC) and CO emissions were significantly lower. It was found that the NOx emissions used in the California Air Resources Board's (CARB) EMFAC2000 and the U.S. Environmental Protection Agency's (EPA) MOBILE5b emissions inventory models were lower than those measured in all of the idling conditions tested on the 1999 truck.

Engineering↗

Metabolite production of yeasts on a strawberry-agar during storage at 7 degrees C in air and low oxygen atmosphere.

Changes of different quality factors of strawberries have been described until now from a physiological point of view. Possible effects on quality caused by yeast proliferation have not been described. To elucidate the metabolic activity of yeasts (i.e. Debaryomyces melissophilus, Rhodotorula glutinis, Cryptococcus laurentii), isolated from strawberries, they were inoculated on a simulation medium of strawberries (strawberry-agar). Their activity was measured by analysing and correlating microbiological counts, metabolite concentration in the headspace as well as in the medium, and sugar consumption. The isolated yeasts from strawberries could grow on the strawberry-agar, both under air conditions and modified atmosphere (MA) conditions. The maximum count for the yeasts reached 7.5-8.5 log cfu cm(-2) (air conditions) and 5.6-6.4 log cfu cm(-2) (MA conditions). Production or consumption of a number of compounds could be detected when microbial counts reached levels between 4.7 log cfu cm(-2) and 8.5 log cfu cm(-2) depending on species and atmospheric conditions. A range of volatile organic compounds, produced by the yeasts, was detected: acetone, ethyl acetate, ethanol, isopropyl acetate, ethyl butyrate, 1-propanol, 2-methyl-1-propanol, 1-butanol, 2-methyl-1-butanol, 3-methyl-1-butanol, 1-hexanol and hexyl acetate. These compounds are able to influence the sensory properties of strawberries. A simultaneous decrease in sugar concentrations (sucrose, glucose, fructose) was observed. When ethanol reached high concentrations, ethyl acetate and ethyl butyrate were produced. This production can be attributed to a detoxification of ethanol by yeasts. The fermentative metabolism of yeasts during aerobic conditions could be explained by the Crabtree effect. As the detected volatile organic compounds produced by yeasts are also found in fresh strawberries, it can be concluded that these compounds are produced both by microbiological and physiological processes.

Colony Count, Microbial↗

[Condensation water drainage of cooling systems in cold storage rooms--a problem of hygiene].

There has been accumulation of water and of dusty dirt in many condensation water containers of cooling systems in cold-storage rooms. Random but thorough microbiological testing of these accumulations in hospital kitchens proved the presence of possible agents that promote spoiling of food, pathogens of infections and food poisons. This is due to technical and hygienic flaws particularly as far as maintenance and condensation drainage are concerned. There are no regulations for technical and hygienic standards in cold-storage rooms e.g. according to DIN, ISO or VDI. However, such regulations are essential. Cooling systems should be included in the DIN 1986 prescriptions (air-conditioned systems) or receive their own regulations. On account of the present findings air-condition systems require specification and extension of the existing standards esp. in the area of condensation drainage and regular disinfectant cleaning.

Drainage, Sanitary↗

The effectiveness of stand alone air cleaners for shelter-in-place.

UNLABELLED: Stand-alone air cleaners may be efficient for rapid removal of indoor fine particles and have potential use for shelter-in-place (SIP) strategies following acts of bioterrorism. A screening model was employed to ascertain the potential significance of size-resolved particle (0.1-2 microm) removal using portable high efficiency particle arresting (HEPA) air cleaners in residential buildings following an outdoor release of particles. The number of stand-alone air cleaners, air exchange rate, volumetric flow rate through the heating, ventilating and air-conditioning (HVAC) system, and size-resolved particle removal efficiency in the HVAC filter were varied. The effectiveness of air cleaners for SIP was evaluated in terms of the outdoor and the indoor particle concentration with air cleaner(s) relative to the indoor concentration without air cleaners. Through transient and steady-state analysis of the model it was determined that one to three portable HEPA air cleaners can be effective for SIP following outdoor bioaerosol releases, with maximum reductions in particle concentrations as high as 90% relative to conditions in which an air cleaner is not employed. The relative effectiveness of HEPA air cleaners vs. other removal mechanisms was predicted to decrease with increasing particle size, because of increasing competition by particle deposition with indoor surfaces and removal to HVAC filters. However, the effect of particle size was relatively small for most scenarios considered here. PRACTICAL IMPLICATIONS: The results of a screening analysis suggest that stand-alone (portable) air cleaners that contain high efficiency particle arresting (HEPA) filters can be effective for reducing indoor fine particle concentrations in residential dwellings during outdoor releases of biological warfare agents. The relative effectiveness of stand-alone air cleaners for reducing occupants' exposure to particles of outdoor origin depends on several factors, including the type of heating, ventilating and air-conditioning (HVAC) filter, HVAC operation, building air exchange rate, particle size, and duration of elevated outdoor particle concentration. Maximum particle reductions, relative to no stand-alone air cleaners, of 90% are predicted when three stand-alone air cleaners are employed.

Aerosols↗

Legionella spp. in Puerto Rico cooling towers.

Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10(5) cells per ml, which is within the range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.

Air Conditioning↗

[Humidifier lung].

Breathing air from a humidifier or an air conditioning unit contaminated by various microorganisms can cause an acute lung disease involving fever, cough and dyspnea, termed "humidifier fever". This type of hypersensitivity pneumonitis was first described in 1959 by PESTALOZZI in the Swiss literature and subsequently by BANASZAK et al. in the Anglo-American. Here a chronic form of this disease which led to pulmonary fibrosis is described: A 37-year-old woman who works in a cheese shop presented with dyspnea which had been progressive over two years, weight loss, a diffuse reticular pattern radiographically and a severe restrictive defect in lung function tests. Open lung biopsy revealed chronic interstitial and alveolar inflammation with non-caseating granulomas and fibrotic changes. Circulating immune complexes and precipitins against the contaminated humidifier water and cheese mites were found, but no antibodies suggesting legionnaires' disease. Two out of five otherwise healthy employees of this cheese shop, where a new humidifying system had been installed 7 years earlier, also had precipitins against the contaminated water from the humidifier and the cheese mites. Despite ending of exposure and longterm steroid and immunosuppressive therapy, the signs and symptoms of pulmonary fibrosis persisted. Contrary to the acute disease, this chronic form is termed "humidifier lung". The importance is stressed of investigating the possibility of exposure to contaminated humidifiers or air conditioning units in all cases of newly detected pulmonary fibrosis.

Adult↗

The effects of alternative smoking policies on indoor air quality in 27 office buildings.

The effect of alternative smoking policies, which prohibited or restricted smoking, on indoor air quality was studied in 27 air-conditioned office buildings. Carbon monoxide, carbon dioxide, respirable particulates, formaldehyde, ultraviolet particulate matter (u.v.PM), nicotine, air temperature, relative humidity and illumination were measured at eight sample sites in each building. Smoking policy had no effect on carbon monoxide, carbon dioxide, relative humidity, formaldehyde, air temperature or illumination for open office areas. It did have an effect on levels of respirable suspended particulates, ultraviolet particulate matter and nicotine.

Air Conditioning↗

Preventing airborne contamination.

The air in a hospital contains a variety of contaminants originating from outdoor air, but also significant concentrations of compounds emitted indoors. All of these are transferred and distributed via the central heating, ventilation and air conditioning (HVAC) systems unless protective measures are taken.

Air Conditioning↗

Indoor air quality investigations at five classrooms.

Five classrooms, air-conditioned or naturally ventilated, at five different schools were chosen for comparison of indoor and outdoor air quality. Temperature, relative humidity (RH), carbon dioxide (CO2), sulphur dioxide (SO2), nitric oxide (NO), nitrogen dioxide (NO2), particulate matter with diameter less than 10 microns (PM10), formaldehyde (HCHO), and total bacteria counts were monitored at indoor and outdoor locations simultaneously. Respirable particulate matter was found to be the worst among parameters measured in this study. The indoor and outdoor average PM10 concentrations exceeded the Hong Kong standards, and the maximum indoor PM10 level was even at 472 micrograms/m3. Air cleaners could be used in classrooms to reduce the high PM10 concentration. Indoor CO2 concentrations often exceeded 1,000 microliters/l indicating inadequate ventilation. Lowering the occupancy and increasing breaks between classes could alleviate the high CO2 concentrations. Though the maximum indoor CO2 level reached 5,900 microliters/l during class at one of the sites, CO2 concentrations were still at levels that pose no health threats.

Air Conditioning↗

Prevalence of anti-Legionella pneumophila antibodies in various groups with different risk factors in Seville (Spain).

A study was undertaken to establish the background prevalence of antibodies to L. pneumophila in 324 persons from the area of Seville, Spain. The serum specimens were obtained from healthy volunteers divided into groups with different risk factors. The results were as follows: a prevalence of 1.96% in 51 persons working in a cooling-tower air conditioned building (group A), a prevalence of 25% in 36 persons working in a dry-heat air conditioned building (group B), a prevalence of 16% in 87 underground construction workers (group C) and a prevalence of 1.2% in 150 healthy blood donors with none of the above risk factors (group D). There is statistical significance between D and B and C.

Adolescent↗

Oxygen-induced retinopathy in newborn rats: orthograde axonal transport changes in optic pathways.

The aim of this study was to evaluate axonal transport along the optic pathways of neonatal rats in which oxygen-induced retinopathy had been experimentally produced. One group of 116 rats was exposed to an FiO2 of 80% for the first 5 days of life and then kept under room-air conditions for the following 10 days. A second group of 108 rats was maintained under room-air conditions for the first 15 days of life. On the 16th day of life, 1.5 microliter of [35S]taurine was injected into the vitreous of the right eye of each animal and radioactivity was measured, at various intervals from the injection, in the right optic nerve, the chiasma and the left optic tract. Statistically significant reductions in axonal transport were observed in all three segments of the optic pathways of the oxygen-supplemented animals compared with the control group. The authors discuss various explanations for their findings and hypothesize that the alterations observed in this study may have significant and more or less long-term effects on the normal maturation of the visual system.

Animals↗

[Effect of selected weather conditions and air pollution on the number of emergency service calls in Cracow].

The paper presents the results of statistical research into the connection between the weather and aerosanitary conditions on the one hand, and on the other hand the number of the emergency service calls in the selected Emergency Wards and kinds of diseases treated during those calls. There seems to be a strong correlation between the number of emergency calls and the appearance of atmospheric fronts and the concentration of dust and sulphur dioxide in the air.

Adult↗

Stability of meropenem in normal saline solution after storage at room temperature.

The bactericidal activity of meropenem is determined by the time that concentrations in tissue and serum are above the MIC for the pathogens during the dosing interval. Thus, the most effective mode of administering of meropenem is continuous infusion. However, the stability of meropenem reconstituted in solution is influenced by the storage temperature. Until now we have had no data to evaluate the stability of this drug during continuous infusion in a tropical country. The objective of this study was to provide such data. Meropenem 0.5 g and 100 ml normal saline solution were mixed together and stored at room temperature for 8 hours. Half of the solution was stored in a room with air conditioning at 20 degrees C and the other half of the solution was stored in a room without air conditioning at 32 degrees-37 degrees C. The concentrations of meropenem in the solution were measured at 0, 1, 2, 3, 4, 6 and 8 hours after the drug was reconstituted. Twelve lots of (0.5 g meropenem in normal saline) solution were evaluated in each temperature condition. The mean meropenem concentrations reconstituted in normal saline solution decreased 1.66%, 3.31% and 5.80% after 2, 4 and 8 hours storage at 20 degrees C, respectively. Drug concentrations decreased 3.14%, 5.86% and 11.85% after 2, 4 and 8 hours storage at 32 degrees-37 degrees C, respectively. Therefore, we conclude that this agent should not be administered by 8-hour continuous infusion at room temperature in a tropical country.

Anti-Bacterial Agents↗