Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “continuous space simulations”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Long term organ culture of human prostate tissue in a NASA-designed rotating wall bioreactor.

PURPOSE: To maintain ex vivo integral prostatic tissue including intact stromal and ductal elements using the NASA-designed Rotating Wall Vessel (RWV) which maintains colocalized cells in an environment that promotes both three-dimensional cellular interactions together with the uniform mass transfer of nutrients and metabolic wastes. MATERIALS AND METHODS: Samples of normal prostate were obtained as a byproduct of transurethral prostatectomy or needle biopsy. Prostatic tissue dissected into small 1 x 1 mm. blocks was cultured in the Rotating Wall Vessel (RWV) Bioreactor for various time periods and analyzed using histological, immunochemical, and total cell RNA assays. RESULTS: We report the long term maintenance of benign explanted human prostate tissue grown in simple culture medium, under the simulated microgravity conditions afforded by the RWV bioreactor. Mesenchymal stromal elements including blood vessels and architecturally preserved tubuloglandular acini were maintained for a minimum of 28 days. Cytokeratins, vimentin and TGF-beta2 receptor and ligand were preserved through the entire culture period as revealed by immunocytochemistry. Prostatic acid phosphatase (PAP) was continuously expressed during the culture period, although somewhat decreased. Prostatic specific antigen (PSA) and its transcript were down regulated over time of culture. Prostatic carcinoma cells from the TSU cell line were able to invade RWV-cultured benign prostate tissue explants. CONCLUSIONS: The RWV bioreactor represents an additional new technology for culturing prostate tissue for further investigations concerning the basic physiology and pathobiology of this clinically important tissue.

Bioreactors↗

Selection of artificial gravity by animals during suborbital rocket flights.

White rats selected preferred artificial gravity levels by locomotion in centrifuges consisting of two runways mounted in the nose of sounding rockets. Roll rate of the Aerobee 150A rocket was designed to produce an angular velocity of 45 r.p.m. during 5 min of free-fall, providing a gravity range range from 0.3 to 1.5 G depending on a subject's runway position. One animal was released at the high and one at the low gravity position in each flight. Animal positions were continuously recorded. Flight subjects were selected from about 100 trained animals adapted to the simulated launch environment for several months. In two flights excessive rollrates produced gravity ranges above the designed limits. In two other flights the desired range was produced. Locomotion patterns during these flights were similar. All four animals explored the entire available G-range. One rat settled at 0.4 G after 2 min; the others crossed the 1-G location in progressively narrower excursions and were near earth gravity at the end of the test period. Data were more varible than in laboratory tests above 1 G and the observation periods were necessarily few and short. Tentatively, however, the data suggest that normal earth-reared rats select earth gravity when available magnitudes include values above and below 1 B. Modification of gravity preference by prolonged exposure to higher or lower levels remains a possibility.

Animals↗

Effects of prolonged bed rest on the total peripheral resistance baroreflex.

Orthostatic intolerance following prolonged exposure to microgravity continues to be a primary concern of the human space program. Reduced autonomic tone has been demonstrated to contribute to this phenomenon, and the heart rate baroreflex, in particular, has been repeatedly shown to be impaired. However, only the works of Yelle et al. have attempted to address the role of the total peripheral resistance (TPR) baroreflex, a potentially more significant contributor to blood pressure regulation. We applied a previously developed method for estimating the static gains of both the arterial and cardiopulmonary TPR baroreflexes to data obtained before and after 16-day bed rest. Reductions in the estimated static gains of the arterial (statistically significant) and cardiopulmonary TPR baroreflexes were found after bed rest. This study supports the works of Yelle et al, which imply that the TPR baroreflex is reduced after spaceflight.

Adult↗

Pollutant dispersion in a large indoor space. Part 2: Computational fluid dynamics predictions and comparison with a scale model experiment for isothermal flow.

UNLABELLED: This paper reports on an investigation of the adequacy of computational fluid dynamics (CFD), using a standard Reynolds Averaged Navier-Stokes (RANS) model, for predicting dispersion of neutrally buoyant gas in a large indoor space. We used CFD to predict pollutant (dye) concentration distribution in a water-filled scale model of an atrium with a continuous pollutant source in the absence of furniture and occupants. Predictions from the RANS formulation are comparable with an ensemble average of independent identical experiments. Model results were compared with pollutant concentration data in a horizontal plane from experiments in a scale model atrium. Predictions were made for steady-state (fully developed) and transient (developing) pollutant concentrations. Agreement between CFD predictions and ensemble averaged experimental measurements is quantified using the ratios of CFD-predicted and experimentally measured dye concentration at a large number of points in the measurement plane. Agreement is considered good if these ratios fall between 0.5 and 2.0 at all points in the plane. The standard k-epsilon two-equation turbulence model obtains this level of agreement and predicts pollutant arrival time to the measurement plane within a few seconds. These results suggest that this modeling approach is adequate for predicting isothermal pollutant transport in a large room with simple geometry. PRACTICAL IMPLICATIONS: CFD modeling of pollutant transport is becoming increasingly common but high quality comparisons between CFD and experiment remain rare. Our results provide such a comparison. We demonstrate that the standard k-epsilon model provides good predictions for both transient and fully developed pollutant concentrations for an isothermal large space where furnishings are unimportant. This model is less computationally intensive than a large eddy simulation or low Reynolds number k-epsilon model.

Air Movements↗

Using EMG to anticipate head motion for virtual-environment applications.

In virtual environment (VE) applications, where virtual objects are presented in a see-through head-mounted display, virtual images must be continuously stabilized in space in response to user's head motion. Time delays in head-motion compensation cause virtual objects to "swim" around instead of being stable in space which results in misalignment errors when overlaying virtual and real objects. Visual update delays are a critical technical obstacle for implementing head-mounted displays in applications such as battlefield simulation/training, telerobotics, and telemedicine. Head motion is currently measurable by a head-mounted 6-degrees-of-freedom inertial measurement unit. However, even given this information, overall VE-system latencies cannot be reduced under about 25 ms. We present a novel approach to eliminating latencies, which is premised on the fact that myoelectric signals from a muscle precede its exertion of force, thereby limb or head acceleration. We thus suggest utilizing neck-muscles' myoelectric signals to anticipate head motion. We trained a neural network to map such signals onto equivalent time-advanced inertial outputs. The resulting network can achieve time advances of up to 70 ms.

Adult↗

Light transport in two-layer tissues.

We study theoretically light backscattered by tissues using the radiative transport equation. In particular we consider a two-layered medium in which a finite slab is situated on top of a half space. We solve the one-dimensional problem in which a plane wave is incident normally on the top layer and is the only source of light. The solution to this problem is obtained formally by imposing continuity between the solutions for the upper and lower layers. However, we are interested solely in probing the top layer. Assuming that the optical properties in the lower layer are known, we remove it from the problem yielding a finite slab problem by prescribing an alternate boundary condition. This boundary condition is derived using the theory of Green's functions and is exact. Hence, one needs only to solve the transport equation in a finite slab using this alternate boundary condition. We derive an asymptotic solution for the case when the slab is optically thin. We extend these results to the three-dimensional problem using Fourier transforms. These results are validated by comparisons with numerical solutions for the entire two-layered problem.

Biological Transport↗

The experimental evaluation of a prototype rotating slat collimator for planar gamma camera imaging.

A collimator consisting of a series of parallel slats has been constructed and used in conjunction with a conventional gamma camera to collect one-dimensional projections of the radioisotope distribution being imaged. With the camera remaining stationary, the collimator was made to rotate continuously over the face of the detector and the projections acquired were used to reconstruct a planar image by the theory of computed tomography. The propagation of noise on image reconstruction was largely offset by the increased geometric efficiency that resulted from the enlarged solid angle of acceptance afforded by the slat collimator. For a uniform disc of activity the signal to noise ratio (SNR) at a point in an image reconstructed by convolution and backprojection is shown to be given by [formula:see text] and Q1(xi) is the one-dimensional filter function in Fourier space. Improved noise behaviour was observed for images acquired with the slat collimator compared to those acquired with a low-energy high-resolution (LEHR) collimator for small distributions of activity. Spatial resolution with the slat collimator was approximately equal to that obtained with an LEHR collimator and improved contrast was observed in images of small hot regions.

Biophysical Phenomena↗

Stromal elements for tumor diagnosis: a brief review of diagnostic electron microscopic features.

Tumor diagnosis mainly depends on the appearance of the tumor cells in recapitulating the appearance of primordial cells from which they arise. However, certain tumors may present with specific stromal changes that may assist/enhance the diagnosis. In this presentation, diagnostic stromal features have been reviewed. The cytoplasm is enclosed by a unit membrane, which serves as a barrier to, as well as an interface with, surrounding structures. Epithelial cells usually show characteristic basal-apical orientation. In mesenchymal tissue, different types of interface can be found in different types of mesenchymal tissue. External lamina can be defined as an anatomic structure, which encloses anatomic functional units. In epithelial tissue, cells in a functional unit are enclosed within a well-defined external lamina (EL). In malignant epithelial tumors, EL can become increasingly indistinct as tumors become less differentiated, and one has to look for it diligently. Within the external lamina, epithelial cells are closely packed with closely apposed cell membranes and cell attachment junctions. In contrast to epithelial tissue, mesenchymal tissue is usually characterized by the stromal elements they produce. Individual cells are embedded in the stroma, and individual mesenchymal cells represent the functional unit. Vascular endothelial cells are an exception since their relationship to stroma resembles to that of epithelial cells. Thus, tumors deriving from mesenchymal cells known to have external lamina such as muscle cells and Schwann cells tend to show total enclosure of cells by external lamina. In malignant muscle tumors, external lamina production can be focally present and found only by diligent search. In Schwann cell tumors, the presence of EL is prominent in low-grade tumors and more irregular and variable in malignant tumors. In the latter, stromal aggregation of scrolls of external lamina can be characteristic. Similar features are seen in ossifying fibromyxoid tumors. Fibronexus junctions (composed of extracellular fibronectin fillements linking intracellular 5-nm filaments) is claimed to be typical of myofbroblasts. Finding them in spindle cell tumors justifies a diagnosis of myofibroblastomas. There have been several stromal changes diagnostic for certain tumors found only by electron microscopy. Fibrous long-spaced collagen (known as Luse bodies) is diagnostic for peripheral nerve sheath tumors, but they can rarely be found in other tumors. Luse bodies usually appear as focally as crystallized aggregates apart from the regular collagenous interstitial stroma. They should be distinguished from other nonspecific long-spaced collagen changes. The changes are diffusely stromal in contrast to Luse bodies. Spiny collagen and amianthoid fibers are interesting collagen fibrils and their diagnostic value is questionable. Skeinoid fibers (SF) are short-spaced collagen of 41- to 45-nm banding so-named because of their peculiar appearance by electron microscopy simulating skeins of yarn. They were originally described in neurogenic tumors and small intestinal stromal tumors with features of gastrointestinal autonomic nerve tumors (GANT). Although there have been a few sporadic case reports of the presence of skeinoid fibers in nonneurogenic tumors, the frequent presence of SF in spindle cell tumors signifies their neurogenic nature in this authors' experience. An exception to this is that SF can be a constant element of rare ciliary body tumors known as ciliary mesectodermal leiomyomas, in which tumor cells show some resemblance to smooth muscle as well as Schwann cells. In addition to SF, several other types of peculiar crystallized collagen were observed in GANT tumors, particularly those with multiple tumor syndromes such as neurofibromatosis and Carney's triad. They simulate the appearance of railroad tracks or centrosomes. The reason for this is not known. The authors speculate that such collagen crystallization may be caused by genetic alterations involving collagenosis. Further studies will be necessary to clarify their pathogenesis. Another peculiar stromal change is electron-dense stromal filamentous aggregates with extra-long banding of > 250-nm periodicity previously described in Ewing sarcomas. This stromal change simulating a tiger skin pattern is also seen in primitive neuroectodermal tumors and malignant melanomas. In view of continually new discoveries of stromal changes that can be used for the differential diagnosis of tumors, the importance of close evaluation of stromal elements of tumors, and diligent application of electron microscopy in tumor diagnosis cannot be overemphasized.

Cytoplasm↗

Changes in size and compliance of the calf after 30 days of simulated microgravity.

Increased leg venous compliance may contribute to postflight orthostatic intolerance in astronauts. We reported that leg compliance was inversely related to the size of the muscle compartment. The purpose of this study was to test the hypothesis that reduced muscle compartment after long-duration exposure to microgravity would cause increased leg compliance. Eight men, 31-45 yr old, were measured for vascular compliance of the calf and serial circumferences of the calf before and after 30 days of continuous 6 degrees head-down bed rest. Cross-sectional areas (CSA) of muscle, fat, and bone compartments in the calf were determined before and after bed rest by computed tomography. From before to after bed rest, calculated calf volume (cm3) decreased (P less than 0.05) from 1,682 +/- 83 to 1,516 +/- 76. Calf muscle compartment CSA (cm2) also decreased (P less than 0.05) from 74.2 +/- 3.6 to 70.6 +/- 3.4; calf compliance (ml.100 ml-1.mmHg-1.100) increased (P less than 0.05) from 3.9 +/- .7 to 4.9 +/- .5. The percent change in calf compliance after bed rest was significantly correlated with changes in calf muscle compartment CSA (r = 0.72, P less than 0.05). The increased leg compliance observed after exposure to simulated microgravity can be partially explained by reduced muscle compartment. Countermeasures designed to minimize muscle atrophy in the lower extremities may be effective in ameliorating increased venous compliance and orthostatic intolerance after spaceflight.

Adult↗

Surgeon-specific factors in the acquisition of laparoscopic surgical skills.

BACKGROUND: Training and experience vary widely among surgeons performing laparoscopic surgery (LS). Visual perceptual demands are greater for LS than for traditional surgery, necessitating greater understanding of surgeon variables in skill acquisition and performance. METHODS: During an LS skills course incorporating didactic and simulator-based instruction, 94 surgeons completed an experience/demographic questionnaire, a test of course-specific knowledge acquisition, 10 trials of three dexterity drills, 15 suturing trials using course-specific methods, and 3 standardized tests of visual perception. RESULTS: Age, years posttraining, and visual perception correlated significantly with time required to complete drills and suturing trials (Pearson correlations ranged from r = 0.21, P <0.05, to r = 0.51, P <0.001) even after statistically controlling for variations in knowledge acquisition, which correlated (r = 0.30, P <0.01) with suturing speed. CONCLUSIONS: Surgeon variables play a significant role in speed of acquisition and performance of LS skills. Further studies need to elucidate their role in quality of LS performance.

Adult↗

Can interstitial glucose assessment replace blood glucose measurements?

Current treatment regiments for individuals depending on exogenous insulin are based on measurements of blood glucose obtained through painful finger sticks. The shift to minimal or noninvasive continuous glucose monitoring primarily involves a shift from blood glucose measurements to devices measuring subcutaneous interstitial fluid (ISF) glucose. As the development of these devices progresses, details of the dynamic relationship between blood glucose and interstitial glucose dynamics need to be firmly established. This is a challenging task insofar as direct measures of ISF glucose are not readily available. The current article investigated the dynamic relationship between plasma and ISF glucose using a model-based approach. A two-compartment model system previously validated on data obtained with the MiniMed Continuous Glucose Monitoring System (CGMS) is reviewed and predictions from the original two-compartment model were confirmed using new data analysis of glucose dynamics in plasma and hindlimb lymph (lymph is derived from ISF) in the anesthetized dog. From these data sets, the time delay between plasma and ISF glucose in dogs was established (5-12 minutes) and a simulation study was performed to estimate the errors introduced if ISF is taken as a surrogate for blood. From the simulation study, the error component resulting from the differences in plasma and ISF glucose was estimated to be < 6% during normal day-to-day use in an individual with diabetes (error component calculated as the standard deviation of the ISF/plasma glucose differences under conditions where the maximal time delay was used). This difference is most likely within the variance between arterial and venous blood glucose. We conclude that the differences between plasma and ISF glucose will not be a significant obstacle in advancing the use of ISF as an alternative to blood glucose measurements.

Biosensing Techniques↗

Potential application of a triaxial three-dimensional fabric (3-DF) as an implant.

Various three-dimensional fabrics (3-DFs) woven with a triaxial three-dimensional (3A-3D) structure in which the warps, wefts and vertical fibres are three-dimensionally orientated with orthogonal, off-angle, cylindrical or complex fibre alignments using a single long fibre, which may be one of several kinds of fibres, have been developed. The physical strengths and behaviour of these fabrics under different external forces were measured for such stress-strain relationships as compressive, tensile and cyclic bending, compressing torsional and compressive tensile systems to evaluate the effect of the continuous loading caused by living body movements over a long period of time. The 3-DFs led to downward convex 'J'-shaped curves in stress-strain profiles, because they were markedly flexible at low strain levels, but became rigid as strain increased. In this behaviour they reflected the behaviour of natural cartilage rather than that of conventional artificial biomaterials. There were also some 3-DFs that showed hysteresis loss curves with quite similar mechanical strengths and behaviour to natural intervertebral discs with regard to the compressive-tensile cyclic stress and showed little variation from the first 'J'-shaped hysteresis profile even after 100,000 deformation cycles. Accordingly, it has been shown that, without a doubt, 3-DFs can be effective implants possessing both design and mechanical biocompatibilities as well as the durability necessary for long-term implantation in the living body. The surface of bioinert linear low-density polyethylene coating on multifilaments of ultra-high molecular weight polyethylene, a constructional fibre of 3A-3D weaving, was modified by treatment with corona-discharge and spray-coating of unsintered hydroxyapatite powder to impart chemical (surface) compatibility and biological activity, respectively. Since the modified surface of the 3-DF was ascertained to have affinity and activity with simulated body fluid, an orthogonal 3-DF block was implanted in the tibia of a rabbit. Sufficient surrounding tissues entering into the textural space of the 3-DF could be observed at 4 weeks after implantation and the load necessary to break the block away from the bone reached a high value at 8 weeks. These results decisively showed that the 3-DFs could also acquire chemical (surface) and biological biocompatibilities and bonding capacity with bone and soft tissues through modification of the surface of the constructional fibre. The 3-DFs have definite potential in such applications as novel and effective artificial articular cartilages, intervertebral discs, menisci and materials for osteosynthesis and prosthesis, and the like.

Animals↗

A mathematical and experimental simulation of the hematological response to weightlessness.

Two ground-based methods of weightlessness simulation--a computer model of erythropoiesis feedback regulation and bedrest--were used to investigate the mechanisms which lead to loss of red cell mass during spaceflight. Both methods were used to simulate the first Skylab mission of 28 days. Human bedrest subjects lose red cell mass linearly with time and in this study the loss was 6.7% at the end of four weeks (compared to 14% in Skylab). Postbedrest recovery of red cell mass was delayed for two weeks during which time a further decline in this quantity was noted. This is consistent with the first Skylab mission but not with the two longer flights of two and three months. Hemoconcentration, observed early in the study, was essentially maintained despite red cell loss because of continued loss of plasma volume. The computer model, using the time-varying hematocrit data to estimate red cell production rates, predicted dynamic behavior of plasma volume and red cell mass that was in close agreement with the measured values. The results support the hypothesis that red cell loss during supine bedrest is a normal physiological feedback process in response to hemoconcentration enhanced tissue oxygenation and suppression of red cell production. In contrast, the delayed postbedrest recovery of red cell mass was more difficult to explain, especially in the light of enhanced reticulocyte indices observed at the onset on ambulation. Model simulation suggested the possibilities, still to be experimentally demonstrated, that this period was marked by some combination of increased oxygen-hemoglobin affinity, small reductions in mean red cell life span, ineffective erythropoiesis, or abnormal reticulocytosis. The question of whether hemoconcentration is the sole contributor to spaceflight red cell losses also remains to be resolved.

Bed Rest↗

Numerical analysis of blood flow in the clearance regions of a continuous flow artificial heart pump.

The CFVAD3 is the third prototype of a continuous flow ventricular assist device being developed for implantation in humans. The pump consists of a fully shrouded 4-blade impeller supported by magnetic bearings. On either side of this suspended rotating impeller is a small clearance region through which the blood flows. The spacing and geometry of these clearance regions are very important to the successful operation of this blood pump. Computational fluid dynamics (CFD) solutions for this flow were obtained using TascFlow, a software package available from AEA Technology, U.K. Flow in these clearance regions was studied parametrically by varying the size of the clearance, the blood flow rate into the pump, and the rotational speed of the pump. The numerical solutions yield the direction and magnitude of the flow and the dynamic pressure. Experimentally measured pump flow rates are compared to the numerical study. The results of the study provide guidance for improving pump efficiency. It is determined that current clearances can be significantly reduced to improve pump efficiency without negative impacts.

Computer Simulation↗

"Smart" baroreception along the aortic arch, with reference to essential hypertension.

Beat-to-beat regulation of heart rate is dependent upon sensing of local stretching or local "disortion" by aortic baroreceptors. Distortions of the aortic wall are due mainly to left ventricular output and to reflected waves arising from the arterial tree. Distortions are generally believed to be useful in cardiac control since stretch receptors or aortic baroreceptors embedded in the adventitia of the aortic wall, transduce the distortions to cardiovascular neural reflex pathways responsible for beat-to-beat regulation of heart rate. Aortic neuroanatomy studies have also found a continuous strip of mechanosensory neurites spread along the aortic inner arch. Although their purpose is now unknown, such a combined sensing capacity would allow measurement of the space and time dependence of inner arch wall distortions due, among other things, to traveling waves associated with pulsatile flow in an elastic tube. We call this sensing capability--"smart baroreception." In this paper we use an arterial tree model to show that the cumulative effects of wave reflections, from many sites far downstream, have a surprisingly pronounced effect on the pressure distribution in the root segment of the tree. By this mechanism global hemodynamics can be focused by wave reflections back to the aortic arch, where they can rapidly impact cardiac control via smart baroreception. Such sensing is likely important to maintain efficient heart function. However, alterations in the arterial tree due to aging and other natural processes can lead in such a system to altered cardiac control and essential hypertension.

Animals↗

Role of cation gradients in hypercontracture of myocytes during simulated ischemia and reperfusion.

We examined the relationship between transsarcolemmal cation gradients and hypercontracture of cardiac myocytes in ischemia and reperfusion using adult rat ventricular myocytes superfused with buffer mimicking normal or ischemic extracellular fluid. Contractile performance of electrically stimulated cells was recorded by an optical video system simultaneously with measurements of intracellular Ca2+ concentration ([Ca2+]i) using fura-2 or intracellular pH (pHi) using 2',7'-bis(2-carboxyethyl)-5(6)-carboxyfluorescein. While cells were exposed to simulated ischemia buffer, the transsarcolemmal H+ gradient was abolished, [Ca2+]i transient stopped, and twitch contraction of myocytes ceased. Upon reperfusion with normal buffer, H+ gradient was quickly restored, Ca2+ transients restarted with transient increase in systolic Ca2+, and twitch contraction restarted with development of hypercontracture, which continued after [Ca2+]i returned to preischemic level even in the presence of near-normal concentrations of high-energy phosphates. When the transsarcolemmal proton, Na+, and Ca2+ gradients were altered so that Na+ entry via Na(+)-H+ exchange and Ca2+ entry via Ca(2+)-Na+ exchange were made less favorable, the transient systolic overshoot of Ca2+ at reperfusion and development of hypercontracture was largely avoided. These results suggest that Na+ and then Ca2+ entry via the Na(+)-H+ and Na(+)-Ca2+ exchangers, respectively, probably contribute to the increase in [Ca2+]i and hypercontracture of myocytes at time of reperfusion in this model.

Acidosis↗

A mathematical study of anterior dental relations: Part II, Incisor and canine overjet.

A mathematical model of anterior inter-arch relations was described in a previous article. This model is modified and manipulated and, using hypothetical dental measurements, results are generated and presented. The present work continues the two-dimensional examination of anterior dental relations in the first article, the emphasis remaining on incisor and canine overjet. Other authors have started by observing ideal occlusions, then have worked backwards to gain ratios of preferred maxillary to mandibular teeth widths; this restricts their studies to Class I occlusions with complete anterior dentitions and similar anterior form of both arches. This paper has no premise of normal or initial ratios. Incorporation of multiple factors allows forming and testing of hypotheses of anterior dental relations. Many factors influence anterior dental relations in varying degrees. Some dental measurement changes examined here are: the sum of teeth widths in each arch; spacing; crowding; angle of the arc of each arch and the antero-posterior buccal relation. Summary tables are presented to aid the prediction of the direction of inter-arch response to change in a dental measurement. Some inferences are discussed and are presented as a series of principles considered valid for this model. The principles may warrant testing with other arch form models.

Computer Simulation↗

Decompression sickness and bubble formation in females exposed to a simulated 7.8 psia suit environment.

The purpose of this study was to measure female susceptibility to decompression sickness (DCS) during simulated extravehicular activity (EVA) at a candidate (7.8 psia) suit pressure. Thirty female volunteer subjects, in groups of three, were exposed to three consecutive daily EVA simulations at 7.8 psia (5,031 m altitude equivalent) continuously for 6 h. During each altitude exposure, the subjects breathed a gas mixture of 50% oxygen/50% nitrogen, and participated in exercise workloads similar to those expected to be experienced by astronauts during a typical EVA scenario. Precordial Doppler bubble monitoring was accomplished after each cycle of exercise workload simulations. During at least 1 of the 3 days (d) of exposure, 43% of the subjects experienced intravenous bubbling. Of the 30 subjects, 17 (57%) did not experience detectable bubbling on any of the 3 d of exposure and 5 (17%) developed decompression sickness (DCS) during the study. Two cases were delayed, occurring after recompression to ground level; and three subjects required hyperbaric oxygen treatment. The results of this study suggest that female subjects may suffer more delayed DCS symptoms, necessitating hyperbaric oxygen treatment, than their male counterparts under the same experimental conditions. Female subjects did not experience intravenous bubbling as frequently as male subjects when exposed to these study conditions.

Adult↗