Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Radius”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Minimally invasive reduction and osteosynthesis of articular fractures of the distal radius.

Treatment of displaced fractures of the distal radius has changed over the course of time. For many years, closed reduction with plaster immobilization was considered the treatment of choice. Subsequent use of pins and plaster, percutaneous pin fixation, and the development of external fixation devices all contributed to improving fracture stability. More recently a new generation of external fixation devices has been developed to permit distraction and palmar translation. In addition, over the past twenty years, we have seen the development of more sophisticated internal fixation devices for the treatment of displaced fractures of the distal radius. The indications for open reduction and internal fixation have been defined largely on the basis of numerous studies which support the concept that articular malreduction is predictive of traumatic arthritis and poor functional result. Knirk and Jupiter have reported poor results for intra-articular fractures of the distal radius having an articular step-off greater than 2 mm. More recently, wrist arthroscopy has been used to improve visualization of articular surfaces and aid fracture reduction. In addition, bone grafting techniques have been employed more frequently to accelerate fracture healing. With improvement in techniques, we are able to provide our patients with better functional results and return them to their activities of daily living and vocation more rapidly.

Arthroscopy↗

Augmented external fixation of distal radius fractures: a biomechanical analysis.

An in vitro model of an unstable extra-articular distal radius fracture was created in 8 fresh-frozen cadaveric specimens and stabilized with an external fixator. Rotation and translation kinematics of the distal radial fracture fragment were measured in relation to the proximal radius during physiologic loading, using infrared light-emitting diodes and a 3-dimensional motion-sensing device. The effect of supplemental single and combination Kirschner wire (K-wire) fixation on fracture fragment stability was assessed. Fixation of supplemental K-wires to the fixator frame via a custom-developed outrigger assembly was also analyzed. Significant reductions in sagittal plane (flexion/extension) rotation and neutral zone were recorded when the fracture fragment was stabilized with a single styloid or dorsal transfixion K-wire. Equivalent stability was afforded by attachment of a nontransfixion K-wire to the fixator frame via the outrigger assembly. The dorsal constructs compared favorably to the styloid constructs in reduction of the sagittal plane neutral zone and coronal (radioulnar) rotation. These data lend biomechanical support to the concept of augmentation of distal radius external fixation and provide a physiologic model to test fixation methods for other fracture patterns.

Bone Wires↗

In vivo measurement of radius calcium/phosphorus ratio by X-ray absorptiometry.

We describe a new method for assessing the skeletal Ca/P ratio in vivo using X-ray absorptiometry. By placing cerium (Ce) and samarium (Sm) filters in the X-ray beam from a commercial X-ray source (Norland), mean photon energies of 39 and 89 keV were obtained. The instrument was designed to take measurements of the forearm, at a site located at the distal 1/3 of the radius. The system was calibrated with three bone phantoms: Ca10(PO4)6(OH)2, Ca(HPO4)(H2O)2 and Ca(HPO4)2(H2O)). The precision for measuring the Ca/P ratio in the human radius was 2.3% CV for a skin dose to the forearm ranging from 0.3 to 0.4 mGy, depending on the width of the arm. The Ca/P ratio of the radius was significantly lower in patients with postmenopausal osteoporosis than in premenopausal controls.

Absorptiometry, Photon↗

Prediction of the viscosity radius and the size exclusion chromatography behavior of PEGylated proteins.

Size exclusion chromatography (SEC) was used to determine the viscosity radii of equivalent spheres for proteins covalently grafted with poly(ethylene glycol) (PEG). The viscosity radius of such PEGylated proteins was found to depend on the molecular weight of the native protein and the total weight of grafted PEG but not on PEG molecular weight, or PEG-to-protein molar grafting ratio. Results suggest grafted PEG's form a dynamic layer over the surface of proteins. The geometry of this layer results in a surface area-to-volume ratio approximately equal to that of a randomly coiled PEG molecule of equivalent total molecular weight. Two simple methods are given to predict the viscosity radius of PEGylated proteins. Both methods accurately predicted (3% absolute error) the viscosity radii of various PEG-proteins produced using three native proteins, alpha-lactalbumin (14.2 kDa MW), beta-lactoglobulin dimer (37.4 kDa MW), and bovine serum albumin (66.7 kDa MW), three PEG reagents (2400, 5600, and 22500 MW), and molar grafting ratios of 0 to 8. Accurate viscosity radius prediction allows calculation of the distribution coefficient, K(av), for PEG-proteins in SEC. The suitability of a given SEC step for the analytical or preparative fractionation of different PEGylated protein mixtures may therefore be assessed mathematically. The methods and results offer insight to several factors related to the production, purification, and uses of PEGylated proteins.

Chromatography, Gel↗

Implications of the contact radius to line step (CRLS) ratio in AFM for nanotribology measurements.

Investigating the mechanisms of defect generation and growth at surfaces on the nanometer scale typically requires high-resolution tools such as the atomic force microscope (AFM). To accurately assess the kinetics and activation parameters of defect production over a wide range of loads (F(z)), the AFM data should be properly conditioned. Generally, AFM wear trials are performed over an area defined by the length of the slow (L(sscan)) and fast scan axes. The ratio of L(sscan) to image resolution (res, lines per image) becomes an important experimental parameter in AFM wear trials because it defines the magnitude of the line step (LS = L(sscan)/res), the distance the AFM tip steps along the slow scan axis. Comparing the contact radius (a) to the line step (LS) indicates that the overlap of successive scans will result unless the contact radius-line step ratio (CRLS) is < or =(1)/(2). If this relationship is not considered, then the scan history (e.g., contact frequency) associated with a single scan is not equivalent at different loads owing to the scaling of contact radius with load (a proportional variant F(z)(1/3)). Here, we present a model in conjunction with empirical wear tests on muscovite mica to evaluate the effects of scan overlap on surface wear. Using the Hertz contact mechanics definition of a, the CRLS model shows that scan overlap pervades AFM wear trials even under low loads. Such findings indicate that simply counting the number of scans (N(scans)) in an experiment underestimates the full history conveyed to the surface by the tip and translates into an error in the actual extent to which a region on the surface is contacted. Utilizing the CRLS method described here provides an approach to account for image scan history accurately and to predict the extent of surface wear. This general model also has implications for any AFM measurement where one wishes to correlate scan-dependent history to image properties as well as feature resolution in scanned probe lithographies.

Journal Article↗

Monte Carlo calculations on polypeptide chains. VIII. Distribution functions for the end-to-end distance and radius of gyration for hard-sphere models of randomly coiling poly(glycine) and poly(L-alanine).

A Monte Carlo study of the distribution functions for the end-to-end distance and radius of gyration for hard-sphere models of poly(glycine) and poly(L-alanine) random coils has been conducted in the chain-length range n = 3 to 100 monomer units for both unperturbed chains and chains perturbed by long-range interactions (excluded volume effects). The distribution functions for the radius of gyration in all cases have been very precisely calculated, those for the perturbed end-to-end distance less precisely, and those for the unperturbed end-to-end distance least precisely. Empirical distribution functions of the form W(p) = ap-b exp(-cp-d) for the reduced end-to-end distance p = r/"r-2"-one-half and a similar form for the reduced radius of gyration could be least-squares fit to the Monte Carlo data. The expansion factors alpha-r and alpha-s were calculated vs. chain length and were used to test various versions of the two-parameter theory of the excluded volume effect. To be consistent with the chain-length dependence of alpha-r and alpha-s as determined by the Monte Carlo calculations, each of these theories required two different binary cluster integrals, a beta-r based on alpha-r and a beta-s based on alpha-s, both of which were strongly chain-length dependent. Both of these results suggest that the two-parameter theory is not applicable to the models used in this study. It was also found that, except for very short chain lengths, plots of ln alphs-r vs. ln n were linear, and thus that alpha-r could be estimated for long chain lengths. Comparison of these estimates with the experimental data on four polypeptide chains in one-earth solvents that the hard-sphere models used in this study yield expansion factors that do not seriously overestimate the magnitude of the excluded volume effect.

Alanine↗

Radius and chirality dependent conformation of polymer molecule at nanotube interface.

Temperature-dependent conformations of linear polymer molecules adsorbed at carbon nanotube (CNT) interfaces are investigated through molecule dynamics simulations. Model polyethylene (PE) molecules are shown to have selective conformations on the CNT surface, controlled by atomic structures of the CNT lattice and geometric coiling energy. PE molecules form entropy driven assembly domains, and their preferred wrapping angles around large radius CNT (40, 40) reflect the molecule configurations with energy minimums on a graphite plane. While PE molecules prefer 0 degrees wrapping on small radius armchair CNT (5, 5) predominantly at low temperatures, their configurations are shifted to larger wrapping angle ones on a similar radius zigzag CNT (10, 0). A nematic transformation around 280 K is identified through the Landau-de Gennes theory, with molecule aligning along tube axis in extended conformations.

Adsorption↗

DFT studies of the methyl exchange reaction between Cp2M-CH3 or Cp*2M-CH3 (Cp = C5H5, Cp* = C5Me5, M = Y, Sc, Ln) and CH4. Does M ionic radius control the reaction?

The activation energies for the methyl exchange reactions between Cp2M-CH3 and H-CH3 have been calculated for M = Sc, Y and representative metals of the lanthanide family (La, Ce, Sm, Ho, Yb and Lu) with DFT(B3PW91) calculations with large-core pseudopotentials for M. The sigma-bond metathesis reactions are calculated to have lower activation energies for early lanthanides than for late lanthanides and any of group 3 metals. The relative activation barriers are analyzed using the NBO charge distributions in the reactant and in the transition states. It is shown that the methane needs to be polarized in the transition state as H((+delta))-CH3((-delta)) by the reactant, because this sigma-bond metathesis is best viewed as heterolytic cleavage of methane, leading to a proton transfer between two methyl groups in the field of an electropositive M metal. Early lanthanides, which are involved in strongly ionic metal-ligands bonds are thus associated with the lowest activation energies. The ionic radius and the steric effects influence the relative rates of reaction for the complexes of Sc, Y and Lu. In agreement with earlier works of Sherer et al., the experimental reactivity trends found by Tilley are reproduced best with Cp*2M-CH3 (Cp* = C5Me5) rather than Cp2M-CH3 (Cp = C5H5) because the steric bulk of C5Me5 deactivates most the complex where the metal has the smallest ionic radius (Sc). While the steric effects and the influence of the metal ionic radius cannot be neglected, these factors are not the only ones involved in determining the activation barriers of the sigma-bond metathesis reaction.

Journal Article↗

Phakometric measurement of ocular surface radius of curvature and alignment: evaluation of method with physical model eyes.

Ophthalmophakometric measurements of ocular surface radius of curvature and alignment were evaluated on physical model eyes encompassing a wide range of human ocular dimensions. The results indicated that defocus errors arising from imperfections in the ophthalmophakometer camera telecentricity and light source collimation were smaller than experimental errors. Reasonable estimates emerged for anterior lens surface radius of curvature (accuracy: 0.02-0.10 mm; precision 0.05-0.09 mm), posterior lens surface radius of curvature (accuracy: 0.10-0.55 mm; precision 0.06-0.20 mm), eye rotation (accuracy: 0.00-0.32 degrees; precision 0.06-0.25 degrees), lens tilt (accuracy: 0.00-0.33 degrees; precision 0.05-0.98 degrees) and lens decentration (accuracy: 0.00-0.07 mm; precision 0.00-0.07 mm).

Corneal Topography↗

Botulinum toxin type B (MYOBLOC) versus botulinum toxin type A (BOTOX) frontalis study: rate of onset and radius of diffusion.

BACKGROUND: Botulinum toxin types A and B can improve the appearance of facial wrinkles. Differences in the time until onset and the degree of diffusion have been observed anecdotally, but no direct comparative studies have been done. OBJECTIVE: To compare the rate of onset and the radius of diffusion of botulinum toxin types A and B in the rhytides of the forehead. METHODS: Adults with symmetrical moderate to severe forehead wrinkles at full contracture received botulinum toxin type A (BOTOX; 5 U) on one side of the forehead and type B (MYOBLOC; 500 U) on the other side. Photographs taken at rest and full frontalis contracture were analyzed by computer, and a time-lapse motion picture was created. Radius of diffusion and time until full effect were measured. RESULTS: Botulinum toxin type B had a slightly faster onset of action than type A. All patients responded to type B quickly, whereas some had a delayed response to type A. A greater radius of diffusion was consistently observed with botulinum toxin type B, as measured by the greater area of wrinkle reduction at the doses used. CONCLUSIONS: In this comparative study of patients with symmetrical forehead wrinkles, botulinum toxin type B produced a greater area of diffusion and a more rapid onset of action than type A.

Adult↗

[Results of corrective osteotomy of malunited extension fractures of the radius at the usual site].

BACKGROUND: There is an increasing interest in the corrective osteotomy for the malunited distal radius fracture. Already in the seventies we developed an operative technique for the correction of the malunited Colles' fracture. The technique is based on a special plate, which facilitates precise restoration of the angulation of the joint surface and the length of the radius. The purpose of our study is to investigate the results of our method and to compare them with results in the literature. PATIENTS AND METHODS: We examined retrospectively the patients with a malunited Colles' fracture corrected by our technique until August 1996. The investigated criteria were range of motion, grip strength, pain relief, and X-ray findings. RESULTS: Until August 1996, we have performed 124 corrective osteotomies for malunited Colles' fractures; 115 were carried out by our technique; 91 of them could be examined. The mean follow-up time was 4.5 years. The range of motion has improved in all planes, especially for flexion. Grip strength increased but still remained below the level of the opposite side. On X-ray, average dorsal tilt of the radiocarpal joint was 24 degrees preoperatively and was reduced to an almost normal palmar tilt of 7 degrees. Ulnar-plus variance was reduced from 6 mm to less than 1 mm. CONCLUSION: Corrective osteotomy of the distal radius is of great benefit and leads to improved hand function and diminished pain. The use of our special plate facilitates this ambitious operation considerably.

Adult↗

Dependence of center radius on temporal frequency for the receptive fields of X retinal ganglion cells of cat.

We examined the dependence of the center radius of X cells on temporal frequency and found that at temporal frequencies above 40 Hz the radius increases in a monotonic fashion, reaching a size approximately 30% larger at 70 Hz. This kind of spatial expansion has been predicted with cable models of receptive fields where inductive elements are included in modeling the neuronal membranes. Hence, the expansion of the center radius is clearly important for modeling X cell receptive fields. On the other hand, we feel that it might be of only minor functional significance, since the responsivity of X cells is attenuated at these high temporal frequencies and the signal-to-noise ratio is considerably worse than at low and midrange temporal frequencies.

Animals↗

Wavelengths for port wine stain laser treatment: influence of vessel radius and skin anatomy.

Recent Monte Carlo computations in realistic port wine stain (PWS) models containing numerous uniformly distributed vessels suggest equal depth of vascular injury at wavelengths of 577 and 585 nm. This finding contradicts clinical experience and previous theory. From a skin model containing normal and PWS vessels in separate dermal layers, we estimate analytically the average volumetric heat production in the deepest targeted PWS vessel. The fluence rate distribution is approximated by Beer's law, which depends upon the tissue's effective attenuation coefficient, and includes a homogeneous fractional volumetric blood concentration corrected for finite-size blood vessels. The model predicts 585-587 nm wavelengths are optimal in adult PWSs containing at least one layer of small-radius blood vessels. In superficial PWSs, typically in young children with small-radius vessels, 577-580 nm wavelengths are optimal. Wavelength-independent results similar to those from Monte Carlo models are valid in single-layered PWSs of large-radius vessels. In conclusion, the volumetric heat production in the deepest targeted PWS blood vessel can be maximized on an individual patient basis. However, absorption of 585-587 nm wavelengths is sufficiently high in superficial lesions, so we hypothesize that these wavelengths may be considered adequate for the treatment of any PWS.

Adult↗

Nodule detection in digital chest radiography: summary of the RADIUS chest trial.

As a part of the Europe-wide research project 'Unification of physical and clinical requirements for medical X-ray imaging'-governed by the Radiological Imaging Unification Strategies (RADIUS) Group-a major image quality trial was conducted by members of the group. The RADIUS chest trial aimed at thoroughly examining various aspects of nodule detection in digital chest radiography, such as the effects of nodule location, system noise, anatomical noise, and anatomical background. The main findings of the RADIUS chest trial concerning the detection of a lung nodule with a size in the order of 10 mm can be summarised as: (1) the detectability of the nodule is largely dependent on its location in the chest, (2) the system noise has a minor impact on the detectability at the dose levels used today, (3) the disturbance of the anatomical noise is larger than that of the system noise but smaller than that of the anatomical background and (4) the anatomical background acts as noise to a large extent and is the major image component affecting the detectability of the nodule.

Artifacts↗

Computation of the solvent-accessible surface area of monomer nonionic contrast media. Consequences for used probe radius in the study of hydrophilic characteristics.

RATIONALE AND OBJECTIVES: The solvent-accessible surface areas of different monomer nonionic contrast media were calculated for different probe radii. By correlating these areas with an experimental (octanol/water partition coefficient) and a calculated parameter (COMB-C), implications for the radius of the probe volume are pointed out. METHODS: The solvent-accessible surface areas of seven monomer nonionic iodinated contrast media were calculated with GEPOL (a program able to calculate various molecular surfaces and volumes) for a wide range of probe radii of the solvent. These areas were correlated with the octanol/ water partition coefficient and COMB-C, a parameter describing the spatial distribution of the hydrophilic elements of a molecule. RESULTS: The correlation coefficients of the solvent-accessible surface areas (determined with the different probe radii) with the octanol/water partition coefficient and of the solvent-accessible surface areas (determined with the same probe radii) with COMB-C were good. This correlation was better for probe raddi of 3 A or more. CONCLUSIONS: COMB-C, a parameter designed earlier, correlated well with the hydrophilia of a monomer nonionic contrast molecule. It was shown that a probe radius of at least 3 A should be used when correlations with hydrophilic characteristics are studied, rather than a probe radius of 1.5 A, which is generally used in assessment of solubilities of molecules in biologic environment. Implications are discussed.

Computer Systems↗

High axial length/corneal radius ratio as a risk factor in the development of myopia.

Results of refractive component measurements have shown that eyes of Melanesian schoolchildren living in Vanuatu, almost all of whom are emmetropic, have relatively short axial lengths and relatively flat corneas in comparison to emmetropic eyes of children examined in England. Evidence is presented to suggest that the relation between the axial length of the eye and corneal radius--the axial length/corneal radius (AL/CR) ratio--may be a useful predictor of future refractive state. Mean axial length/corneal radius ratios for 6- to 19-year-old Melanesian school children were found to be 2.88 for boys and 2.86 for girls, as compared to mean AL/CR ratios for 6- to 19-year-old British schoolchildren of 3.05 for boys and 3.04 for girls. It is proposed that an eye having a high AL/CR ratio is at risk for the development of myopia, and that such an eye has maintained its state of emmetropia by virtue of a compensatory flattening of the crystalline lens. In order to test the proposition that an increase in axial length occurs as a precursor to the development of myopia, a prospective longitudinal study of a group of 6- to 7-year-old schoolchildren is proposed.

Adolescent↗

Compensatory spinopelvic balance over the hip axis and better reliability in measuring lordosis to the pelvic radius on standing lateral radiographs of adult volunteers and patients.

STUDY DESIGN: Sagittal alignments, including lumbar lordosis and spinopelvic balance (measured from C7, S1, and hip axis reference points for the relative positions of the spine and sacropelvis over the hips), were studied on standing 36-in. lateral radiographs of adult volunteers (control subjects) and patients who had specific spinal disorders. OBJECTIVES: To determine the most reliable methods for measuring lumbopelvic lordosis and to define significant spinopelvic compensations for sagittal balance. SUMMARY OF BACKGROUND DATA: Measurements for standing sagittal balance, obtained using a C7 plumb line, and segmental angulations of the spinal vertebrae, including lordosis to the sacrum, have been reported. Absolute values, even for normative data, have had wide variation and limited clinical usefulness. Correlations of sagittal balance with the reported spinopelvic angulations (spinal vertebral and sacropelvic angulations) have not been well defined. In addition, determinates of balance (spinal and pelvic) have not been studied for reliability, and compensatory mechanisms for maintenance of balance have not been carefully evaluated. Better recognition of the correlations and more reliable methods to measure lordosis and balance and the spinopelvic compensations for its maintenance may be beneficial in treating patients who have spinal disorders. METHODS: Measurements on standing 36-in. lateral radiographs were made for sagittal alignments in adult volunteers (n = 50) and in adult patients who had symptomatic degenerative lumbar disc disease (n = 50), low grade L5-S1 isthmic (lytic) spondylolisthesis (n = 30), and idiopathic or degenerative scoliosis (n = 30). All participants exhibited clinical compensation for balance. Data were analyzed for significant correlations within each group to determine compensatory correlations of spinopelvic balance with the other sagittal alignments. Intraobserver and interobserver reliability for the parameters evaluated were calculated. This included two methods for determining lordosis (S1 end-plate and pelvic radius techniques). RESULTS: Plumb line measurements for balance from the S1 and hip axis reference points, as defined, were similar in all four groups. However, the groups appeared to adjust for balance by using common and distinctive spinopelvic compensations that resulted in significantly and characteristically different angular alignments among the four groups. Lordosis and balance measurements were closely correlated, and the correlation was characterized by pelvic rotation and translation around the hip axis. The subjects with less lordosis typically stood with the C7 plumb line anterior to and at a longer distance from the sacral reference point. This was primarily because of posterior sacropelvic translation around the hip axis and not because the sagittal plumb line initially moved anteriorly away from the sacrum. This was true in all four groups and gave the appearance that the sacropelvis was less well balanced over the hips in the subjects with less lordosis. Even small differences in lordosis appeared to be associated with considerable adjustments in the other spinopelvic alignments. Therefore, it was important to determine that lordosis was lumbopelvic more reliably measured by the pelvic radius technique. CONCLUSIONS: Lower lumbar lordosis, by the pelvic radius technique, and compensatory sacropelvic translation around a hip axis, in addition to measurements from this axis to the C7 plumb line, were the primary determinates and most reliable radiographic assessments for sagittal balance. Understanding the common and characteristically different compensations that occur with balance in these patients who had specific spinal disorders may help to improve their care.

Adult↗

The pi plate: an implant for unstable extension fractures of the distal radius in patients with osteoporotic bone.

Extension fractures of the distal radius are very common injuries in elderly women caused by moderate energy trauma. Nevertheless there is no consensus about how these fractures should be treated. Anatomic reduction of the distal radius is necessary to achieve good functional results. In particular, the elderly patient, who may have to use crutches or a walker, will need a pain-free wrist under axial load. The pi plate is designed for distal radius fractures. It has been widely criticized for causing irritation and/or rupture of the extensor tendons. Most complications of the implant can be avoided with a careful operative technique. To prevent ruptures of the extensor tendon implant removal after 4 to 6 months is recommended. In osteoporotic bone the pi plate guarantees good stability with minimal postoperative loss of reduction. The operative technique is described in detail and common complications are discussed.

Journal Article↗