An approach to the surveying of radiation environments for radiation protection purposes.

Many of the inadequacies of the system presently used for surveying environments containing penetrating radiation stem from the impossibility of defining a radiation parameter which is additive, measurable and closely related to peak dose equivalent in the body. Many of the present conceptual difficulties would be eliminated if surveys were made in terms of a quantity 'dose equivalent ceiling' defined as the sum of the peak dose equivalents generated by all the components of the field if each were incident normally to the front face of an anthropomorphic phantom. 'Dose equivalent ceiling' is close to the quantity measured by existing instruments, is both additive and measurable, and can be rigorously related to primary radiation field quantities. It is always greater than peak dose equivalent in the body, and would be used to define an exposure period during which a given dose equivalent could not be exceeded. The dose to specific parts of the person's body would then be estimated by personal dosimetry. Fields of low penetrating radiation could continue to be surveyed in terms of dose to specific superficial organs. Dose equivalent ceiling, which corresponds to the instrumental measurement, exceeds dose equivalent index, an indication of peak dose equivalent in the body, by a factor which can be as large as six.

Gamma Rays↗

Saturation corrections for plane-parallel ionization chambers.

Experiments described in the literature lead to different formulae for saturation corrections in ionization chambers. To elucidate the differences, saturation curves of an extrapolation chamber irradiated with beta particles from 90Sr+90Y sources have been studied experimentally. The results could be described by one formula which was a combination of known formulae for charge collection losses due to volume recombination, initial recombination and diffusion.

Mathematics↗

Leakage testing of medical radium sources.

The results of leakage tests on approximately 2000 clinical radium sources in current use in several hospitals are presented. The tests were carried out using a liquid scintillation immersion method. Less than 1% of the sources leaked radon gas (222Rn) to an extent greater than 1 nCi/24 h. The consequences of a small leakage of radon from a source while implanted in tissue are considered and compared with the hazards and problems created when sources leak during storage. A leakage rate of 1 nCi/24 h is suggested as an appropriate limit beyond which sources should be removed from use.

Radiation Monitoring↗

Comparison of two independent methods for determining the neutron/gamma sensitivity of a dosemeter.

Results obtained with two independent methods for measuring the n/gamma sensitivity of non-hydrogenous dosemeters are compared for the neutron beam produced by 8.3 MeV deuterons on beryllium. In one method, a pure neutron field is simulated by taking the difference between measurements made at diffrent angles in a mixed field with an isotropic gamma-ray component. In the second method, the mixed (n+gamma) beam is purified by lead filtration. An assumption in the lead filtration method is that the background radiation is invariant under three different beam conditions. This assumption was found not be be valid in our experimental arrangement; and caused the values obtained for the n/gamma sensitivity to be systematically high. A modification was made in the lead filtration method so that the dosemeter response to background could be determined for each beam condition. Good agreement was obtained between the results of the spectral difference and modified lead filtration methods.

Air↗

A model to calculate the induced dose rate around an 18 MV ELEKTA linear accelerator.

The dose rate due to activity induced by (gamma, n) reactions around an ELEKTA Precise accelerator running at 18 MV is reported. A model to calculate the induced dose rate for a variety of working practices has been derived and compared to the measured values. From this model, the dose received by the staff using the machine can be estimated. From measured dose rates at the face of the linear accelerator for a 10 x 10 cm2 jaw setting at 18 MV an activation coefficient per MU was derived for each of the major activation products. The relative dose rates at points around the linac head, for different energy and jaw settings, were measured. Dose rates adjacent to the patient support system and portal imager were also measured. A model to calculate the dose rate at these points was derived, and compared to those measured over a typical working week. The model was then used to estimate the maximum dose to therapists for the current working schedule on this machine. Calculated dose rates at the linac face agreed to within +/- 12% of those measured over a week, with a typical dose rate of 4.5 microSv h(-1) 2 min after the beam has stopped. The estimated maximum annual whole body dose for a treatment therapist, with the machine treating at only 18 MV, for 60000 MUs per week was 2.5 mSv. This compares well with value of 2.9 mSv published for a Clinac 21EX. A model has been derived to calculate the dose from the four dominant activation products of an ELEKTA Precise 18 MV linear accelerator. This model is a useful tool to calculate the induced dose rate around the treatment head. The model can be used to estimate the dose to the staff for typical working patterns.

Computer Simulation↗

Monte Carlo evaluation of kerma in an HDR brachytherapy bunker.

In recent years, the use of high dose rate (HDR) after-loader machines has greatly increased due to the shift from traditional Cs-137/Ir-192 low dose rate (LDR) to HDR brachytherapy. The method used to calculate the required concrete and, where appropriate, lead shielding in the door is based on analytical methods provided by documents published by the ICRP, the IAEA and the NCRP. The purpose of this study is to perform a more realistic kerma evaluation at the entrance maze door of an HDR bunker using the Monte Carlo code GEANT4. The Monte Carlo results were validated experimentally. The spectrum at the maze entrance door, obtained with Monte Carlo, has an average energy of about 110 keV, maintaining a similar value along the length of the maze. The comparison of results from the aforementioned values with the Monte Carlo ones shows that results obtained using the albedo coefficient from the ICRP document more closely match those given by the Monte Carlo method, although the maximum value given by MC calculations is 30% greater.

Brachytherapy↗

A radio-frequency system for in vivo pilot experiments aimed at the studies on biological effects of electromagnetic fields.

An exposure system consisting of two long transversal electromagnetic (TEM) cells, operating at a frequency of 900 MHz, is presented and discussed. The set-up allows simultaneous exposure of a significant number of animals (up to 12 mice per cell) in a blind way to a uniform plane wave at a frequency of 900 MHz, for investigating possible biological effects of exposure to electromagnetic fields produced by wireless communication systems. A heating/refrigerating system has also been designed for maintaining comfortable environmental conditions within the TEM cells during experiments. An accurate dosimetric study has been performed both numerically and by means of direct measurements on phantoms and living mice. The results have shown that good homogeneity of exposure and adequate power efficiency, in terms of whole-body specific absorption rate (SAR) per 1 W of input power, are achievable for the biological target.

Electromagnetic Fields↗

On the safety assessment of human exposure in the proximity of cellular communications base-station antennas at 900, 1800 and 2170 MHz.

In this work, the procedures for safety assessment in the close proximity of cellular communications base-station antennas at three different frequencies (900, 1800 and 2170 MHz) are analysed. For each operating frequency, we have obtained and compared the distances to the antenna from the exposure places where electromagnetic fields are below reference levels and the distances where the specific absorption rate (SAR) values in an exposed person are below the basic restrictions, according to the European safety guidelines. A high-resolution human body model has been located, in front of each base-station antenna as a worst case, at different distances, to compute whole body averaged SAR and maximum 10 g averaged SAR inside the exposed body. The finite-difference time-domain method has been used for both electromagnetic fields and SAR calculations. This paper shows that, for antenna-body distances in the near zone of the antenna, the fact that averaged field values be below the reference levels could, at certain frequencies, not guarantee guidelines compliance based on basic restrictions.

Algorithms↗

Evaluation of stray radiofrequency radiation emitted by electrosurgical devices.

Electrosurgery refers to the passage of a high-frequency, high-voltage electrical current through the body to achieve the desired surgical effects. At the same time, these procedures are accompanied by a general increase of the electromagnetic field in an operating room that may expose both patients and personnel to relatively high levels of radiofrequency radiation. In the first part of this study, we have taken into account the radiation emitted by different monopolar electrosurgical devices, evaluating the electromagnetic field strength delivered by an electrosurgical handle and straying from units and other electrosurgical accessories. As a summary, in the worst case a surgeon's hands are exposed to a continuous and pulsed RF wave whose magnetic field strength is 0.75 A m(-1) (E-field 400 V m(-1)). Occasionally stray radiation may exceed ICNIRP's occupational exposure guidelines, especially close to the patient return plate. In the second part of this paper, we have analysed areas of particular concern to prevent electromagnetic interference with some life-support devices (ventilators and electrocardiographic devices), which have failed to operate correctly. Most clinically relevant interference occurred when an electrosurgery device was used within 0.3 m of medical equipment. In the appendix, we suggest some practical recommendations intended to minimize the potential for electromagnetic hazards due to therapeutic application of RF energy.

Electrocardiography↗

Variability among polysulphone calibration curves.

Within an epidemiological study regarding the correlation between skin pathologies and personal ultraviolet (UV) exposure due to solar radiation, 14 field campaigns using polysulphone (PS) dosemeters were carried out at three different Italian sites (urban, semi-rural and rural) in every season of the year. A polysulphone calibration curve for each field experiment was obtained by measuring the ambient UV dose under almost clear sky conditions and the corresponding change in the PS film absorbance, prior and post exposure. Ambient UV doses were measured by well-calibrated broad-band radiometers and by electronic dosemeters. The dose-response relation was represented by the typical best fit to a third-degree polynomial and it was parameterized by a coefficient multiplying a cubic polynomial function. It was observed that the fit curves differed from each other in the coefficient only. It was assessed that the multiplying coefficient was affected by the solar UV spectrum at the Earth's surface whilst the polynomial factor depended on the photoinduced reaction of the polysulphone film. The mismatch between the polysulphone spectral curve and the CIE erythemal action spectrum was responsible for the variability among polysulphone calibration curves. The variability of the coefficient was related to the total ozone amount and the solar zenith angle. A mathematical explanation of such a parameterization was also discussed.

Biocompatible Materials↗

Characterization of the electromagnetic near-field absorption in layered biological tissue in the frequency range from 30 MHz to 6,000 MHz.

Currently, standards for the compliance testing of wireless devices are being extended to cover a wider frequency band and different usage patterns of mobile phones as well as of novel body-worn and handheld devices. As a consequence, not only the head but also strongly varying tissue distributions of the body are exposed to electromagnetic radiation. Several authors have reported changes in the SAR absorption of body tissue due to the presence of a low permittivity fat layer. This paper identifies two different effects which can lead to increased SAR in layered tissue in comparison to the SAR assessed using homogeneous tissue simulating liquid: (1) for larger distances between the tissue and the antenna, standing wave effects occur depending on the frequency and fat layer thickness. (2) In the very close near-field (distances approximately lambda/40), reactive E-field components lead to high local absorption in the skin. The latter effect occurs at lower frequencies and depends on the antenna type. Modification of the parameters of the homogeneous liquids cannot compensate for these effects. However, a conservative exposure estimate can be obtained by applying a multiplication factor between 1 and 3 to the values assessed using current experimental dosimetric techniques.

Absorption↗

Helical tomotherapy shielding calculation for an existing LINAC treatment room: sample calculation and cautions.

This paper reports a step-by-step shielding calculation recipe for a helical tomotherapy unit (TomoTherapy Inc., Madison, WI, USA), recently installed in an existing Varian 600C treatment room. Both primary and secondary radiations (leakage and scatter) are explicitly considered. A typical patient load is assumed. Use factor is calculated based on an analytical formula derived from the tomotherapy rotational beam delivery geometry. Leakage and scatter are included in the calculation based on corresponding measurement data as documented by TomoTherapy Inc. Our calculation result shows that, except for a small area by the therapists' console, most of the existing Varian 600C shielding is sufficient for the new tomotherapy unit. This work cautions other institutions facing the similar situation, where an HT unit is considered for an existing LINAC treatment room, more secondary shielding might be considered at some locations, due to the significantly increased secondary shielding requirement by HT.

Equipment Design↗

Simultaneous determination of equivalent dose to organs and tissues of the patient and of the physician in interventional radiology using the Monte Carlo method.

This study presents the results of computations of organ equivalent doses and effective doses for the patient and the primary physician during an interventional cardiological examination. The simulations were carried out for seven x-ray spectra (between 60 kVp and 120 kVp) using the Monte Carlo code MCNP. The voxel-based whole-body model VIP-Man was employed to represent both the patient and the physician, the former lying on the operation table while the latter standing 15 cm from the patient at about waist level behind a lead apron. The x-rays, which were generated by a point source positioned around the table and were directed with a conical distribution, irradiated the patient's heart under five major projections used in a coronary angiography examination. The mean effective doses under LAO45, PA, RAO30, LAO45/CAUD30 and LLAT irradiation conditions were calculated as 0.092, 0.163, 0.161, 0.133 and 0.118 mSv/(Gy cm2) for the patient and 1.153, 0.159, 0.145, 0.164 and 0.027 microSv/(Gy cm2) for the shielded physician. The effective doses for the patient determined in this study were usually lower than the literature data obtained through measurements and/or calculations and the discrepancies could be attributed to the fact that this study computes the effective doses specific to the VIP-Man body model, which lacks an ovarian contribution to the gonadal equivalent dose. The effective doses for the physician agreed reasonably well with the literature data.

Adult↗

Strategy for population protection and area rehabilitation in Russia in the remote period after the Chernobyl accident.

The report presents the history of the development of criteria for radiation and social protection of the Russian population residing in the areas contaminated with radionuclides after the Chernobyl accident, in the remote time periods after the accident. The tendencies for reduction of standards with time are shown, and their causes are analysed. It is noted that the optimization principle was not applied in the explicit form for population protection. The current radiation situation in the contaminated areas of Russia is described, and the future situation is forecast. Main pathways of external and internal population exposure are described. Modern possibilities for reduction of the population exposure dose are discussed. The authors propose promising criteria and methods for population protection and rehabilitation of contaminated areas in Russia.

Health Physics↗