Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Failure”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Infection after total hip arthroplasty. A study of the treatment of one hundred and six infections.

We evaluated the results of treatment for ninety-seven patients (106 infections in ninety-eight hips) who had had either an infection after a total hip arthroplasty or positive intraoperative cultures of specimens obtained during revision of a total hip arthroplasty for presumed aseptic loosening. The patients were managed according to various protocols on the basis of the clinical setting (positive intraoperative cultures, early postoperative infection, late chronic infection, or acute hematogenous infection). Aerobic gram-positive cocci accounted for 109 (74 per cent) of the 147 microbial isolates; gram-negative bacilli, for twenty-one (14 per cent); and anaerobes, for twelve (8 per cent). The white blood-cell count and erythrocyte sedimentation rate were elevated in association with seventeen (16 per cent) and sixty-seven (63 per cent) of the 106 infections, respectively. The mean duration of follow-up was 3.8 years (range, 0.3 to eleven years). A good result was noted after the initial treatment of twenty-eight (90 per cent) of the thirty-one infections that had been diagnosed on the basis of positive intraoperative cultures at the time of the revision, twenty-five (71 per cent) of the thirty-five early postoperative infections, twenty-nine (85 per cent) of the thirty-four late chronic infections, and three of the six acute hematogenous infections. Of the twenty++-one infections for which the initial therapy failed, twelve eventually were eradicated after additional treatment and the hip had a functional prosthesis at the time of follow-up. Of the ninety-seven infections that were treated successfully (there was a functional retained or exchange prosthesis in place at the time of the most recent follow-up and infection had not recurred at least two years after the discontinuation of antibiotic therapy), nine were associated with subsequent aseptic loosening of the prosthesis. The factors associated with recurrent infection were retained bone cement, the number of previous operations, potential immunocompromise, and early postoperative infection after arthroplasty without cement.

Acute Disease↗

Revision of the acetabular component of a total hip arthroplasty with a massive structural allograft. Study with a minimum five-year follow-up.

The results of the placement of a massive structural acetabular allograft in conjunction with a revision total hip arthroplasty in thirty-two patients (thirty-tree hips) were evaluated at a minimum of five years. The graft supported more than 50 percent of the cup in all of the patients. The goals of a revision operation in a hip that has massive loss of bone are to provide support for the cup, to approximate the normal anatomy, to restore the length of the lower limb, and to restore bone stock should a future revision be necessary. Clinical and radiographic review at an average of seven years (range, five to eleven years) after the revision revealed that eighteen hips had needed no additional operation, seven hips had needed a repeat revision but the structural allograft was intact and had been used to support the cup at the repeat revision, and eight hips had had failure of both the prosthesis and the allograft. The result was considered a clinical and radiographic success when the hip score had increased at least 20 points, the cup was stable, the allograft had united, and no additional operation was necessary. According to these criteria, the rate of success was 55 percent (eighteen of thirty-three hips.) The only factor that was found to be clinically important with respect to outcome was the method of reconstruction. Seven of the eight hips that had been reconstructed with use of a roof-reinforcement ring and a structural allograft had a successful result at an average of 7.5 years (range, five to eleven years). The findings of the present study support the use of a structural allograft in the presence of massive loss of bone in order to achieve the goals of a revision hip replacement. Because of the high rate of success with acetabular reinforcement rings, we now use this method of reconstruction whenever a massive allograft is employed on the acetabular side.

Acetabulum↗

Revision of the acetabular component without cement after total hip arthroplasty. A follow-up note regarding results at seven to eleven years.

The results of revision of the acetabular component without cement, performed for aseptic loosening, were reported previously after a mean of forty-four months for 138 hips (132 patients). After an additional mean duration of follow-up of almost five years, twelve patients (twelve hips) had died before they could be followed long enough for the later study and nine patients (eleven hips) had been lost to follow-up; thus, a total of 111 patients (115 hips) were available for follow-up at a mean of 100 months (range, seventy-eight to 135 months). Between the earlier and later times of follow-up, six additional acetabuli had had a repeat revision: one, for recurrent dislocation; two, for infection; and three (which were stable), at the time of a revision of the femoral stem. No revision of the acetabular cup was performed because of aseptic loosening, and no cup was noted to have migrated. Radiographs were available for 105 patients (109 hips) at a mean of ninety-eight months (range, seventy-eight to 135 months). Five (5 per cent) of the 109 cups were surrounded by a complete radiolucent line and three (3 per cent), by a partial progressive radio-lucent line. A radiolucent line adjacent to a screw was seen in association with two cups (2 per cent), and osteolysis was noted at the margin of four cups (4 per cent). Revision of the acetabular component with a porous-coated, nearly hemispherical fiber-metal component inserted without cement was associated with a high rate of excellent results at the seven to eleven-year follow-up examination.

Acetabulum↗

Direct-exchange arthroplasty for the treatment of infection after total hip replacement. An average ten-year follow-up.

Twenty consecutive patients who had a direct-exchange total hip arthroplasty, performed by one surgeon between October 1979 and July 1990, were prospectively followed and data were collected. The most common infecting organism was Staphylococcus epidermidis (nine patients), followed by Streptococcus species and Staphylococcus aureus (five patients each). Three patients (15 per cent) had a draining sinus tract at the time of the operation. The operation and the postoperative management included meticulous débridement, administration of appropriate systemic antibiotic therapy, and use of antibiotic-loaded cement. By an average of 9.9 years (range, 3.5 to 17.1 years) postoperatively, no patient had had recurrence of the infection. Two patients had a revision for aseptic loosening nine and seventeen years after the direct exchange. Although the present series is relatively small, our experience has shown that direct exchange, which is associated with less morbidity and is less expensive than delayed exchange, can be successful in carefully selected patients.

Adult↗

Total hip arthroplasty with cement in patients who have rheumatoid arthritis. A minimum ten-year follow-up study.

One hundred and six consecutive total hip arthroplasties with cement were performed by one surgeon, at least ten years before the time of the present clinical and radiographic review, in seventy-five patients who had adult-onset rheumatoid arthritis. Two patients (three hips) were lost to follow-up. Seven (7 per cent) of the remaining 103 hips were revised. The revisions were performed because of infection (three hips), dislocation (two hips), or aseptic loosening (two hips). Of the ninety-eight hips that were not lost to follow-up or revised because of infection or dislocation, eight (8 per cent) had radiographic loosening of the acetabular component and two (2 per cent) had radiographic loosening of the femoral component. Although the prevalence of radiographic loosening of the acetabular component was four times greater than the prevalence of radiographic loosening of the femoral component, the prevalence of revision because of aseptic loosening of the acetabular component was identical to that for the femoral component (one component each). These results compared favorably with those of total hip arthroplasty with cement, performed by the same surgeon, for the treatment of other diagnoses. Loosening of the acetabular component was significantly associated with a younger age at the time of the index operation (p = 0.03) and with acetabular osteolysis (p = 0.0006). Of forty-eight hips in thirty-two patients who survived for at least ten years, 96 per cent (forty-six hips) were considered by the patients to have a satisfactory result. At the time of the latest follow-up, twenty-four (75 per cent) of the patients had no pain in the hip. Although eighteen patients (56 per cent) could walk without support at a minimum of ten years after the operation, we found that the functional results for patients who had rheumatoid arthritis were inferior to those observed for patients who had had a total hip arthroplasty with cement, performed by the same surgeon, for the treatment of other diagnoses.

Acetabulum↗

Hydroxyapatite-coated Schanz pins in external fixators used for distraction osteogenesis : a randomized, controlled trial.

BACKGROUND: Complications of external fixation include loosening of the fixation pins and pin-track infection. Laboratory studies and clinical trials have suggested that hydroxyapatite coating improves the osteointegration of various orthopaedic implants. The purpose of this study was to determine whether the prevalence of pin-related complications can be reduced by the use of hydroxyapatite-coated pins in fixators applied for distraction osteogenesis. METHODS: Forty-six consecutive patients undergoing segmental transport or lengthening of the tibia were randomized to the use of either standard titanium Schanz pins or hydroxyapatite-coated stainless-steel Schanz pins. The fixators were used for an average of thirty-eight weeks (range, fourteen to seventy-two weeks). All patients were closely monitored for pin loosening and infection, and digitized radiographs were assessed for bone resorption around all pins. When the external fixator was removed, the torque required to extract the pins was determined with use of an electronic torque wrench. RESULTS: In the control group (titanium pins), twenty-two pins (13%) loosened and an infection occurred at the site of twenty pins. An extensive infection of the canal developed in one patient. Twenty-two pins were removed or replaced because of these complications. In the hydroxyapatite group, no clinical or radiographic signs of pin loosening or infection were observed and no pins required early removal or exchange. The mean torque (and standard deviation) required to remove the hydroxyapatite-coated pins was 0.43 0.18 N-m compared with 0.10 0.09 N-m for the uncoated pins (p < 0.001). CONCLUSION: Coating pins with hydroxyapatite increases their fixation to bone and reduces the rate of infection and loosening during external fixation for distraction osteogenesis. Use of hydroxyapatite-coated pins should be considered in clinical situations requiring prolonged external fixation.

Adolescent↗

Primary Souter-Strathclyde total elbow prosthesis in rheumatoid arthritis.

BACKGROUND: Total elbow arthroplasty is a well-established treatment for the painful elbow joint in patients with rheumatoid arthritis. We present the results of what we believe to be the first prospective study of the Souter-Strathclyde total elbow prosthesis. METHODS: Between June 1982 and December 2000, 204 primary total elbow prostheses were inserted in 166 patients who had rheumatoid arthritis. No patient was lost to follow-up. The mean duration of follow-up was 6.4 years. All patients were examined preoperatively, at one and two years postoperatively, and at regular intervals thereafter. RESULTS: Six of the 204 elbows had pain at rest at the time of the latest follow-up. Ten patients (ten elbows) without previous neurological symptoms had development of paresthesias in the distribution of the ulnar nerve postoperatively. Patients who had pain at rest or at night and those who had ulnar nerve symptoms preoperatively were found to have a significant chance of having the same complaints postoperatively. Pain at rest or at night and a decrease in function during the follow-up period were associated with humeral loosening. Twenty-four elbows had revision of the total elbow prosthesis because of loosening of the humeral component (ten), loosening after fracture (six), dislocation (four), infection (two), restricted range of motion (one), or fracture of the middle part of the humeral shaft, proximal to the prosthesis (one). One prosthesis was removed because of humeral loosening, and eight were removed because of deep infection. Another five prostheses were radiographically loose at the time of the latest follow-up. The rate of implant survival, according to the method of Kaplan-Meier, was 77.4% after ten years and 65.2% after eighteen years. CONCLUSIONS: Total elbow replacement is associated with a high complication rate and therefore may be warranted only for seriously disabled patients. Currently, the results associated with the Souter-Strathclyde total elbow prosthesis are comparable with the results associated with other prostheses, but loosening of the humeral component remains a concern. LEVEL OF EVIDENCE: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.

Activities of Daily Living↗

The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years.

BACKGROUND: Osteolysis and increased polyethylene wear have been reported in association with several designs of modular total knee prostheses. The purpose of the present study was to evaluate a modular posterior stabilized prosthesis to determine its clinical performance as well as the rates of component loosening and osteolysis. METHODS: We performed a prospective, consecutive study of 193 knees in 131 patients who were managed with the modular Insall-Burstein II posterior stabilized total knee prosthesis by one surgeon. The mean age of the patients at the time of surgery was sixty-eight years, and the mean duration of follow-up was seven years (range, five to fourteen years). Clinical evaluation was performed with use of standard knee-scoring systems. Radiographs were evaluated for the presence of radiolucent lines, osteolysis, and loosening. RESULTS: The overall result (as determined with the Hospital for Special Surgery scoring system) was rated as excellent for 112 knees, good for sixty, fair for fifteen, and poor for six. The mean postoperative flexion was 112 degrees. No clinical or radiographic loosening of the tibial component was noted. Eight knees had osteolytic lesions of the tibia. Thin, incomplete, nonprogressive radiolucent lines were noted around thirty tibial components (16%). There were three reoperations. CONCLUSIONS: Despite previous reports of osteolysis, polyethylene wear, and loosening in association with some modular total knee implant designs, there was no loosening in this series of posterior stabilized total knee replacements and only eight knees had tibial osteolysis after a mean duration of follow-up of seven years. We believe that total knee arthroplasties that are performed with use of cemented modular posterior stabilized components can have a high rate of intermediate-term success. LEVEL OF EVIDENCE: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.

Activities of Daily Living↗

Retrievable Günther Tulip filter complicated by sepsis and retroperitoneal hemorrhage: successful management by filter retrieval.

We encountered complications of septic shock and retroperitoneal hemorrhage which occurred after implantation of a retrievable Günther Tulip filter. A 79-year-old woman was diagnosed as right femoral vein thrombosis, and a retrievable Günther Tulip filter was deployed prior to a total knee replacement surgery. However, the patient developed septicemia due to Citrobacter freundii, followed by thrombocytopenia and retroperitoneal hemorrhage. A large hematoma was formed along the lateral side of the filter struts. We considered that the filter should be removed to control retroperitoneal hemorrhage and prevent secondary infection of the hematoma. Removal of the retrievable filter was effective in managing these complications.

Aged↗

Complications of hip arthroplasty causing periprosthetic radiolucency on plain radiographs.

The technique of hip arthroplasty is at least 30 years old and currently is performed 120,000 times per year in the United States [1]. Changes in materials and surgical techniques have markedly decreased the prevalence of infection and aseptic loosening. At the same time, other complications such as stress shielding and aggressive granulomatosis have become increasingly important complications of joint replacement [2]. All four of these entities manifest radiographically as periprosthetic lucency (Fig. 1.). The purpose of this essay is to illustrate the plain film findings of each of these complications.

Adult↗

Detection of infection in loosened hip prostheses: efficacy of sonography.

OBJECTIVE: The purpose of this study was to determine the efficacy of sonography in the detection of infection in loosened hip prostheses. MATERIALS AND METHODS: The normal capsular morphology in 15 asymptomatic patients with total hip replacements was studied sonographically. Sonograms were then obtained in 33 patients who had pain in the hip after arthroplasty and radiologic findings of loosening of the prosthesis. These patients subsequently underwent aspiration and arthrography of the hip. Six of the 33 symptomatic patients proved to have prosthetic joint infection. RESULTS: On sonograms, the normal pseudocapsule is adherent to the proximal part of the anterior femoral cortex, and the capsule-to-bone distance is less than 3.2 mm (average, 2.6 mm). No hips with a capsule-to-bone distance less than 3.2 mm were infected. Sonograms in the six patients with infection showed marked intraarticular effusion with a mean capsule-to-bone distance of 10.2 mm. Five of these six had extracapsular fluid collections. Two patients with hip dislocations and four with aseptic loosening of the prosthesis had capsular distension on sonograms and cultures of aspirated material that showed no growth. CONCLUSION: Sonography can be used to diagnose infection around loosened hip prostheses. All patients who had an intraarticular effusion with extraarticular extension seen on sonograms had infection.

Aged↗