Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pitch Perception”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

The evoked K-complex: all-or-none phenomenon?

The functional significance and topographical variation of the different components of the evoked K-complex were examined. In the first experiment, the intensity of the stimulus (80 and 60 dB SPL) and its rise-and-fall time (2 and 20 milliseconds) were manipulated during nonrapid eye movement sleep. In the second experiment the tonal frequency (500, 1,000 and 2,000 Hz) of the stimulus was manipulated. In the first experiment, nine stimuli were presented every 10 seconds, whereas in the second, 20 consecutive stimuli were presented. The evoked K-complex consisted of two different negative components peaking at approximately 350 and 550 milliseconds, respectively, and followed by a positive component peaking at approximately 900 milliseconds. K-complexes were easier to elicit for high-intensity fast rise-and-fall time stimuli than for low-intensity slow rise-and-fall time stimuli. The probability of occurrence was not affected by the tonal frequency of the stimulus. When a K-complex was evoked, the amplitude and latency of N350, N550 and P900 remained invariant regardless of its intensity, rise-and-fall or its tonal frequency. The N550-P900 portion of the K-complex therefore appears to be an all-or-none phenomenon. On trials in which a K-complex could not be elicited, N350 was still visible although much attenuated. In these trials, its amplitude was further reduced when stimulus intensity was lowered. N350 might need to reach a certain critical threshold before the much larger N550-P900 complex is elicited.

Acoustic Stimulation↗

Human auditory steady state potentials.

The auditory steady state potentials may be an important technique in objective audiometry. The effects of stimulus rate, intensity, and tonal frequency on these potentials were investigated using both signal averaging and on-line Fourier analysis. Stimulus presentation rates of 40 to 45/sec result in a 40 Hz sinusoidal response which is about twice the amplitude of the 10 and 60/sec responses. No significant effects of subject age or sex were seen. The 40/sec response shows a linear decrease in amplitude and a linear increase in latency when stimulus intensity is decreased from 90 to 20 dB normal hearing level. This response is recordable to within a few decibels of behavioral threshold. Stimuli of different tonal frequency give similar amplitude/rate functions, with absolute amplitude decreasing with increasing tonal frequency. Signal averaging and Fourier analysis provide nearly identical amplitude/rate, amplitude/intensity, and latency/intensity functions. Both methods of analysis may be used, therefore, to record the 40 Hz steady state potential. Fourier analysis, however, may be the faster and less expensive method. Furthermore, techniques ("zoom") are available with Fourier analysis to study the effects of varying stimulus parameters on-line with the Fourier analysis procedure.

Acoustic Stimulation↗

Group amplification in schools for the hearing impaired.

In the present field study, ambient noise levels and the status of group FM-wireless amplification systems were examined in 19 classrooms for the hearing impaired. Classroom noise was judged to be unacceptably high thus justifying the need for group amplification devices. Physical inspection of the group systems revealed defects in approximately one-half of the 28 teacher and 89 student amplification units. The electroacoustic measurements showed wide variability in performance among systems. There also appeared to be no systematic relationship between the degree of hearing loss of the children and the amount of unit gain being employed by each specific amplification system.

Amplifiers, Electronic↗

Threshold prediction from the auditory 40-Hz evoked potential.

This is an investigation of the accuracy with which the 40-Hz evoked potential (EP) threshold can be used to predict low frequency behavioral audiometric thresholds. The EP thresholds for 500 and 1000 Hz tone bursts were compared with behavioral thresholds obtained from 40 hearing-impaired ears. Correlation coefficients (between EP and behavioral thresholds) of 0.79 and 0.87 were obtained for the 500 and 1000 Hz signals, respectively. Confidence intervals for EP estimates of behavioral thresholds were -10 to +30 dB for 500 Hz signals and -20 to +20 for 1000 Hz. Problems associated with the use of the EP for predicting behavioral thresholds are discussed.

Adolescent↗

Intracochlear pressure measurements related to cochlear tuning.

Pressure in turn one of the scala tympani (s.t.) was measured close to the basilar membrane (b.m.) and at additional positions as the pressure sensor approached and/or withdrew from the b.m. The s.t. pressure measured within about 100 microm of the b.m. varied rapidly in space at frequencies around the region's best frequency. Very close to the b.m. the s.t. pressure was tuned and scaled nonlinearly with sound level. The scala vestibuli (s.v.) pressure was measured at one position close to the stapes within seconds of the s.t. pressure and served primarily as a reference pressure. The driving pressure across the organ of Corti and the b.m. velocity were derived from the pressure data. Both were tuned and nonlinear. Therefore, their ratio, the specific acoustic impedance of the organ of Corti complex, was relatively untuned, and only subtly nonlinear. The impedance was inspected specifically for negative resistance (amplification) and resonance. Both were detected in some instances; taken as a whole, the current results constrain the possibilities for these qualities.

Acoustic Impedance Tests↗

Effects of low pass filtering on the intelligibility of speech in noise for people with and without dead regions at high frequencies.

People with high-frequency sensorineural hearing loss differ in the benefit they gain from amplification of high frequencies when listening to speech. Using vowel-consonant-vowel (VCV) stimuli in quiet that were amplified and then low pass filtered with various cutoff frequencies, Vickers et aL [J. Acoust. Soc. Am. 110, 1164-1175 (2001)] found that the benefit from amplification of high-frequency components was related to the presence or absence of a cochlear dead region at high frequencies. For hearing-impaired subjects without dead regions, performance improved with increasing cutoff frequency up to 7.5 kHz (the highest value tested). Subjects with high-frequency dead regions showed no improvement when the cutoff frequency was increased above about 1.7 times the edge frequency of the dead region. The present study was similar to that of Vickers et al. but used VCV stimuli presented in background noise. Ten subjects with high-frequency hearing loss, including eight from the study of Vickers et al., were tested. Five had dead regions starting below 2 kHz, and five had no dead regions. Speech stimuli at a nominal level of 65 dB were mixed with spectrally matched noise, amplified according to the "Cambridge" prescriptive formula for each subject and then low pass filtered. The noise level was chosen separately for each subject to give a moderate reduction in intelligibility relative to listening in quiet. For subjects without dead regions, performance generally improved with increasing cutoff frequency up to 7.5 kHz, on average more so in noise than in quiet. For most subjects with dead regions, performance improved with cutoff frequency up to 1.5-2 times the edge frequency of the dead region, but hardly changed with further increases. Calculations of speech audibility using a modified version of the articulation index showed that application of the Cambridge formula was at least partially successful in making high-frequency components of the speech audible for subjects with dead regions, and that such subjects often failed to benefit from increased audibility of the speech at high frequencies.

Aged↗

Perception of the low pitch of frequency-shifted complexes.

When all of the components in a harmonic complex tone are shifted in frequency by delta f, the pitch of the complex shifts roughly in proportion to delta f. For tones with a small number of components, the shift is usually somewhat larger than predicted from pitch theories, which has been attributed to the influence of combination tones [Smoorenburg, J. Acoust. Soc. Am. 48, 924-941 (1970)]. Experiment 1 assessed whether combination tones influence the pitch of complex tones with more than five harmonics, by using noise to mask the combination tones. The matching stimulus was a harmonic complex. Test complexes were bandpass filtered with passbands centered on harmonic numbers 5 (resolved), 11 (intermediate), or 16 (unresolved) and fundamental frequencies (FOs) were 100, 200, or 400 Hz. For the intermediate and unresolved conditions, the matching stimuli were filtered with the same passband to minimize differences in the excitation patterns of the test and matching stimuli. For the resolved condition, the matching stimulus had a passband centered above that of the test stimulus, to avoid common partials. For resolved and intermediate conditions, pitch shifts were observed that could generally be predicted from the frequencies of the partials. The shifts were unaffected by addition of noise to mask combination tones. For the unresolved condition, no pitch shift was observed, which suggests that pitch is not based on temporal fine structure for stimuli containing only high unresolved harmonics. Experiment 2 used three-component complexes resembling those of Schouten [J. Acoust. Soc. Am. 34, 1418-1424 (1962)]. Nominal harmonic numbers were 3, 4, 5 (resolved), 8, 9, 10 (intermediate), or 13, 14, 15 (unresolved) and F0s were 50, 100, 200, or 400 Hz. Clear shifts in the matches were found for all conditions, including unresolved. For the latter, subjects may have matched the "center of gravity" of the excitation patterns of the test and matching stimuli.

Adult↗

Perceived naturalness of spectrally distorted speech and music.

We determined how the perceived naturalness of music and speech (male and female talkers) signals was affected by various forms of linear filtering, some of which were intended to mimic the spectral "distortions" introduced by transducers such as microphones, loudspeakers, and earphones. The filters introduced spectral tilts and ripples of various types, variations in upper and lower cutoff frequency, and combinations of these. All of the differently filtered signals (168 conditions) were intermixed in random order within one block of trials. Levels were adjusted to give approximately equal loudness in all conditions. Listeners were required to judge the perceptual quality (naturalness) of the filtered signals on a scale from 1 to 10. For spectral ripples, perceived quality decreased with increasing ripple density up to 0.2 ripple/ERB(N) and with increasing ripple depth. Spectral tilts also degraded quality, and the effects were similar for positive and negative tilts. Ripples and/or tilts degraded quality more when they extended over a wide frequency range (87-6981 Hz) than when they extended over subranges. Low- and mid-frequency ranges were roughly equally important for music, but the mid-range was most important for speech. For music, the highest quality was obtained for the broadband signal (55-16,854 Hz). Increasing the lower cutoff frequency from 55 Hz resulted in a clear degradation of quality. There was also a distinct degradation as the upper cutoff frequency was decreased from 16,845 Hz. For speech, there was a marked degradation when the lower cutoff frequency was increased from 123 to 208 Hz and when the upper cutoff frequency was decreased from 10,869 Hz. Typical telephone bandwidth (313 to 3547 Hz) gave very poor quality.

Adolescent↗

Intensity discrimination and increment detection in cochlear-implant users.

Intensity difference limens (DLs) were measured in users of the Nucleus 22 and Clarion v1.2 cochlear implants and in normal-hearing listeners to better understand mechanisms of intensity discrimination in electric and acoustic hearing and to evaluate the possible role of neural adaptation. Intensity DLs were measured for three modes of presentation: gated (intensity increments gated synchronously with the pedestal), fringe (intensity increments delayed 250 or 650 ms relative to the onset of the pedestal), and continuous (intensity increments occur in the presence of a pedestal that is played throughout the experimental run). Stimuli for cochlear-implant listeners were trains of biphasic pulses; stimuli for normal-hearing listeners were a 1-kHz tone and a wideband noise. Clarion cochlear-implant listeners showed level-dependent effects of presentation mode. At low pedestal levels, gated thresholds were generally similar to thresholds obtained in the fringe and continuous conditions. At higher pedestal levels, however, the fringe and continuous conditions produced smaller intensity DLs than the gated condition, similar to the gated-continuous difference in intensity DLs observed in acoustic hearing. Nucleus cochlear-implant listeners did not show consistent threshold differences for the gated and fringe conditions, and were not tested in the continuous condition. It is not clear why a difference between gated and fringe thresholds occurred for the Clarion but not the Nucleus subjects. Normal-hearing listeners showed improved thresholds for the continuous condition relative to the gated condition, but the effect was larger for the 1-kHz tonal carrier than for the noise carrier. Findings suggest that adaptation occurring central to the inner hair cell synapse mediates the gated-continuous difference observed in Clarion cochlear-implant listeners and may also contribute to the gated-continuous difference in acoustic hearing.

Acoustic Stimulation↗

Effectiveness of narrow-band versus tonal off-frequency maskers.

The present study was a follow-up to a pilot study in which it was found that a 500-Hz-wide narrow-band noise (NBN) masker produced more masking than a tonal (T) masker for signal frequencies both above and below the masker frequency. The aim of the present study was to determine to what extent these results were influenced by an interaction of the relatively rapid temporal envelope fluctuations of the NBN and the short (10-ms) duration of the signal. In the first experiment, the masking produced by a regular NBN, a low-noise noise (LNN), and a T was compared. The LNN produced less masking than the NBN, and about as much as the T, suggesting that the inherent amplitude fluctuations in the NBN were largely responsible for the greater masking produced by that masker. In the second experiment, the masking produced by a regular NBN was compared with that by a T for a signal duration of 10 or 200 ms. The difference in masking between the two maskers was reduced or eliminated when the signal duration was 200 ms, because the threshold in the presence of the NBN masker decreased more with increasing signal duration. This could reflect a decreased "confusion" between the signal and the inherent fluctuations of the NBN masker.

Acoustic Stimulation↗

Cochlear compression estimates from measurements of distortion-product otoacoustic emissions.

Evidence of the compressive growth of basilar-membrane displacement can be seen in distortion-product otoacoustic emission (DPOAE) levels measured as a function of stimulus level. When the levels of the two stimulus tones (f1 and f2) are related by the formula L1 = 39 dB + 0.4 x L2 [Kummer et al., J. Acoust. Soc. Am. 103, 3431-3444 (1998)] the shape of the function relating DPOAE level to L2 is similar (up to an L2 of 70 dB SPL) to the classic Fletcher and Munson [J. Acoust. Soc. Am. 9, 1-10 (1933)] loudness function when plotted on a logarithmic scale. Explicit estimates of compression have been derived based on recent DPOAE measurements from the laboratory. If DPOAE growth rate is defined as the slope of the DPOAE I/O function (in dB/dB), then a cogent definition of compression is the reciprocal of the growth rate. In humans with normal hearing, compression varies from about 1 at threshold to about 4 at 70 dB SPL. With hearing loss, compression is still about 1 at threshold, but grows more slowly above threshold. Median DPOAE I/O data from ears with normal hearing, mild loss, and moderate loss are each well fit by log functions. When the I/O function is logarithmic, then the corresponding compression is a linear function of stimulus level. Evidence of cochlear compression also exists in DPOAE suppression tuning curves, which indicate the level of a third stimulus tone (f3) that reduces DPOAE level by 3 dB. All three stimulus tones generate compressive growth within the cochlea; however, only the relative compression (RC) of the primary and suppressor responses is observable in DPOAE suppression data. An RC value of 1 indicates that the cochlear responses to the primary and suppressor components grow at the same rate. In normal ears, RC rises to 4, when f3 is an octave below f2. The similarities between DPOAE and loudness compression estimates suggest the possibility of predicting loudness growth from DPOAEs; however, intersubject variability makes such predictions difficult at this time.

Auditory Threshold↗

Robustness of spatial average equalization: a statistical reverberation model approach.

Traditionally, multiple listener room equalization is performed to improve sound quality at all listeners, during audio playback, in a multiple listener environment (e.g., movie theaters, automobiles, etc.). A typical way of doing multiple listener equalization is through spatial averaging, where the room responses are averaged spatially between positions and an inverse equalization filter is found from the spatially averaged result. However, the equalization performance, will be affected if there is a mismatch between the position of the microphones (which are used for measuring the room responses for designing the equalization filter) and the actual center of listener head position (during playback). In this paper, we will present results on the effects of microphone-listener mismatch on spatial average equalization performance. The results indicate that, for the analyzed rectangular configuration, the region of effective equalization depends on (i) the distance of a listener from the source, (ii) the amount of mismatch between the responses, and (iii) the frequency of the audio signal. We also present some convergence analysis to interpret the results.

Architecture↗

Perception of amplitude modulation by hearing-impaired listeners: the audibility of component modulation and detection of phase change in three-component modulators.

Two experiments were conducted to assess whether hearing-impaired listeners have a reduced ability to process suprathreshold complex patterns of modulation applied to a 4-kHz sinusoidal carrier. Experiment 1 examined the ability to "hear out" the modulation frequency of the central component of a three-component modulator, using the method described by Sek and Moore [J. Acoust. Soc. Am. 113, 2801-2811 (2003)]. Scores were around 70-80% correct when the components in the three-component modulator were widely spaced and when the frequencies of the target and comparison different sufficiently, but decreased when the components in the modulator were closely spaced. Experiment 2 examined the ability to hear a change in the relative phase of the components in a three-component modulator with harmonically spaced components. The frequency of the central component, f, was either 50 or 100 Hz. Scores were about 70% correct when the component spacing was < or = 0.5fc, but decreased markedly for greater spacings. Performance was only slightly impaired by randomizing the overall modulation depth from one stimulus to the next. For both experiments, performance was only slightly worse than for normally hearing listeners, indicating that cochlear hearing loss does not markedly affect the ability to process suprathreshold complex patterns of modulation.

Acoustic Stimulation↗

Speech recognition in a special case of low-frequency hearing loss.

Recognition of speech stimuli consisting of monosyllabic words, sentences, and nonsense syllables was tested in normal subjects and in a subject with a low-frequency sensorineural hearing loss characterized by an absence of functioning sensory units in the apical region of the cochlea, as determined in a previous experiment [C. W. Turner, E. M. Burns, and D. A. Nelson, J. Acoust. Soc. Am. 73, 966-975 (1983)]. Performance of all subjects was close to 100% correct for all stimuli presented unfiltered at a moderate intensity level. When stimuli were low-pass filtered, performance of the hearing-impaired subject fell below that of the normals, but was still considerably above chance. A further diminution in the impaired subject's recognition of nonsense syllables resulted from the addition of a high-pass masking noise, indicating that his performance in the filtered quiet condition was attributable in large part to the contribution of sensory units in basal and midcochlear regions. Normals' performance was also somewhat decreased by the masker, suggesting that they also may have been extracting some low-frequency speech cues from responses of sensory units located in the base of the cochlea.

Adult↗

On the relations of intensity jnd's to loudness and neural noise.

It is shown experimentally that, in contradiction of the fundamental concept of Fechner's law, the intensity jnd for auditory sinusoidal signals follows loudness, rather than its derivative with respect to sound intensity. The evidence is obtained by comparing the jnd's of a population with normal hearing to those of a population with hearing loss accompanied by loudness recruitment. Although the recruitment increases the slope of the loudness function, the jnd's of both populations were found to be practically equal when the loudness were equal. The phenomenon is accounted for mathematically by assuming that psychophysically relevant neural noise depends not only on the magnitude of loudness, but also on its derivative with respect to sound intensity. A related derivation accounts for the near miss to Weber's law.

Adult↗

Spatial mapping of intracranial auditory events for various degrees of interaural coherence.

The broadening and splitting of auditory events in dichotic listening conditions with various degrees of interaural coherence are discussed. By using a psychoacoustical mapping method, it has been possible to observe broadening and splitting for a wide range of stimuli, including broadband pink noise as well as bandpass noises with different relative bandwidths and center frequencies. The spatial extents of the auditory events decrease with increasing center frequencies for bandpass stimuli of constant relative bandwidth. The number of partial events for bandpass stimuli decreases with increasing degrees of interaural coherence. These results are, for example, of interest with respect to auditory spaciousness in architectural acoustics.

Attention↗

Informational processing of complex sound. II. Cross-dimensional analysis.

A series of experiments investigated listeners' ability simultaneously to process information across different acoustic dimensions. On each trial, the listener heard a pair of brief n-tone sequences (n = 1 to 12). The frequency, intensity, and duration of each tone in the sequence varied randomly from trial to trial. On average, the values of these three parameters were greater for one sequence, the target, than the other, the nontarget. The listener's task was to identify the target on each trial. For an ideal observer in this task, d' performance grows as the square root n. Obtained d' grew at a rate slightly less than the square root of n. Close to cube root of n growth was observed when the average difference occurred in only one of the three tone parameter values within a block of trials. Although performance fell short of ideal, optimum weights were consistently given to each tone and each parameter. The results are consistent with a model in which performance depends predominantly on the information content of the sounds regardless of how the information is "packaged" in the stimulus. Transmitted information is estimated to be 0.9-2.0 bits within a single acoustic dimension, 2.1-3.0 bits when distributed across dimensions.

Adult↗