Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Motion”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Durability of regenerated articular cartilage produced by free autogenous periosteal grafts in major full-thickness defects in joint surfaces under the influence of continuous passive motion. A follow-up report at one year.

An autogenous graft of tibial periosteum was sutured (with its cambium layer facing into the joint) to the base of a five by ten-millimeter full-thickness defect in the patellar groove of each of forty-five adolescent rabbits. The rabbits were randomly treated postoperatively by either four weeks of immobilization in a cast, intermittent active motion in a cage, or two weeks of continuous passive motion. One year postoperatively, the regenerated tissue from each rabbit was analyzed macroscopically, histologically, histochemically, and biochemically. Gross degenerative changes were seen in 57 per cent of the rabbits that had been immobilized in a cast, in 73 per cent of the rabbits that had been allowed intermittent active motion, and in 22 per cent of the rabbits that had been subjected to continuous passive motion (p less than 0.05). Out of a possible score of 7.0 points for the nature of the regenerated tissue, the scores for the three groups were: immobilization in a cast, 4.1 points; intermittent active motion, 4.0 points; and continuous passive motion, 5.9 points (p greater than 0.05). Out of a possible perfect combined score of 10.0 points for the structural characteristics of the regenerated tissue, the cast-immobilization group scored 3.8 points; the intermittent active-motion group, 2.5 points; and the continuous passive-motion group, 6.4 points (p less than 0.001). The total scores for freedom from cellular changes of degeneration, a perfect score being 5.0 points, were: immobilization in a cast, 2.4 points; intermittent active motion, 2.3 points; and continuous passive motion, 3.9 points (p less than 0.01). Degenerative changes in the adjacent cartilage, which were noted in 42 and 46 per cent of the knees in the immobilization and intermittent active-motion groups, respectively, were not found in the knees that had been subjected to continuous passive motion (p less than 0.05). The total indices, which were derived by combining the scores for all categories (maximum, 24.0 points), revealed that the index for the continuous passive-motion group was significantly better than the index for either of the other two groups: immobilization in a cast, 12.9 points; intermittent active motion, 11.2 points; and continuous passive motion, 19.2 points (p less than 0.0005).(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Movement-induced motion signal distributions in outdoor scenes.

The movement of an observer generates a characteristic field of velocity vectors on the retina (Gibson 1950). Because such optic flow-fields are useful for navigation, many theoretical, psychophysical and physiological studies have addressed the question how ego-motion parameters such as direction of heading can be estimated from optic flow. Little is known, however, about the structure of optic flow under natural conditions. To address this issue, we recorded sequences of panoramic images along accurately defined paths in a variety of outdoor locations and used these sequences as input to a two-dimensional array of correlation-based motion detectors (2DMD). We find that (a) motion signal distributions are sparse and noisy with respect to local motion directions; (b) motion signal distributions contain patches (motion streaks) which are systematically oriented along the principal flow-field directions; (c) motion signal distributions show a distinct, dorso-ventral topography, reflecting the distance anisotropy of terrestrial environments; (d) the spatiotemporal tuning of the local motion detector we used has little influence on the structure of motion signal distributions, at least for the range of conditions we tested; and (e) environmental motion is locally noisy throughout the visual field, with little spatial or temporal correlation; it can therefore be removed by temporal averaging and is largely over-ridden by image motion caused by observer movement. Our results suggest that spatial or temporal integration is important to retrieve reliable information on the local direction and size of motion vectors, because the structure of optic flow is clearly detectable in the temporal average of motion signal distributions. Ego-motion parameters can be reliably retrieved from such averaged distributions under a range of environmental conditions. These observations raise a number of questions about the role of specific environmental and computational constraints in the processing of natural optic flow.

Environment↗

Recognition of dynamic video contents with global probabilistic models of visual motion.

The exploitation of video data requires methods able to extract high-level information from the images. Video summarization, video retrieval, or video surveillance are examples of applications. In this paper, we tackle the challenging problem of recognizing dynamic video contents from low-level motion features. We adopt a statistical approach involving modeling, (supervised) learning, and classification issues. Because of the diversity of video content (even for a given class of events), we have to design appropriate models of visual motion and learn them from videos. We have defined original parsimonious global probabilistic motion models, both for the dominant image motion (assumed to be due to the camera motion) and the residual image motion (related to scene motion). Motion measurements include affine motion models to capture the camera motion and low-level local motion features to account for scene motion. Motion learning and recognition are solved using maximum likelihood criteria. To validate the interest of the proposed motion modeling and recognition framework, we report dynamic content recognition results on sports videos.

Algorithms↗

Normal mode analysis of macromolecular motions in a database framework: developing mode concentration as a useful classifying statistic.

We investigated protein motions using normal modes within a database framework, determining on a large sample the degree to which normal modes anticipate the direction of the observed motion and were useful for motions classification. As a starting point for our analysis, we identified a large number of examples of protein flexibility from a comprehensive set of structural alignments of the proteins in the PDB. Each example consisted of a pair of proteins that were considerably different in structure given their sequence similarity. On each pair, we performed geometric comparisons and adiabatic-mapping interpolations in a high-throughput pipeline, arriving at a final list of 3,814 putative motions and standardized statistics for each. We then computed the normal modes of each motion in this list, determining the linear combination of modes that best approximated the direction of the observed motion. We integrated our new motions and normal mode calculations in the Macromolecular Motions Database, through a new ranking interface at http://molmovdb.org. Based on the normal mode calculations and the interpolations, we identified a new statistic, mode concentration, related to the mathematical concept of information content, which describes the degree to which the direction of the observed motion can be summarized by a few modes. Using this statistic, we were able to determine the fraction of the 3,814 motions where one could anticipate the direction of the actual motion from only a few modes. We also investigated mode concentration in comparison to related statistics on combinations of normal modes and correlated it with quantities characterizing protein flexibility (e.g., maximum backbone displacement or number of mobile atoms). Finally, we evaluated the ability of mode concentration to automatically classify motions into a variety of simple categories (e.g., whether or not they are "fragment-like"), in comparison to motion statistics. This involved the application of decision trees and feature selection (particular machine-learning techniques) to training and testing sets derived from merging the "list" of motions with manually classified ones.

Databases, Protein↗

Motion transparency and coherence in plaids: the role of end-stopped cells.

Humans do not confound the motion of shadows cast upon a surface with the motion of the surface itself, although schemes that propose recombination of orientation-selective motion signals into a rigid motion percept of two-dimensional patterns would predict that they should do so. We propose a simple scheme that avoids recombination and instead attributes perception of two-dimensional pattern motion to the activation of orientation-selective end-stopped units that operate on the logarithm of the luminance. The proposed units respond to the change of contrast along a line, which typically occurs at an intersection. They are not active, however, when a shadow border intersects the edge of an object, because contrast does not change along either of these edges. Thus, end-stopped units signal the motion of transparent intersections weakly or not at all, and the independent motions of the shadow border and the object prevail. We tested two implications of this scheme, using plaids with variable intersection luminance. First, when the intersection luminance was such that it kept the contrast along the intersecting lines nearly constant, the sensitivity for the rigid plaid's direction of motion was minimal, and the sliding motion of the components prevailed. This occurred for light bars on dark backgrounds and for dark bars on light backgrounds. Thus, the effect of the intersection's luminance on the balance between the percepts of rigid-plaid motion and the motion of sliding components was independent of contrast inversion of bar and background. Secondly, when thin lines with the same luminance as the bars covered the borders of the intersection, the intersection's luminance did not affect the rigid-plaid motion percept very much, even when it corresponded to a transparent intersection. This indicates that, when the edges of the intersection and those of the bars were not collinear, the nulling of the end-stopped units did not occur. This result is in line with physiological studies, which showed that the response of an end-stopped cell to a line is only partially inhibited when a similar line is presented non-collinearly with the first in the inhibitory end-zone of its receptive field. Our results are consistent with a scheme in which a second stage of motion detectors combines signals of orientation-selective end-free and orientation-selective end-stopped units for perception of the rigid motion of two-dimensional patterns.

Humans↗

Poor encoding of position by contrast-defined motion.

Second-order (contrast-defined) motion stimuli lead to poor performance on a number of tasks, including discriminating form from motion and visual search. To investigate this deficiency, we tested the ability of human observers to monitor multiple regions for motion, to code the relative positions of shapes defined by motion, and to simultaneously encode motion direction and location. Performance with shapes from contrast-defined motion was compared with that obtained from luminance-defined (first-order) stimuli. When the position of coherent motion was uncertain, direction-discrimination thresholds were elevated similarly for both luminance-defined and contrast-defined motion, compared to when the stimulus location was known. The motion of both luminance- and contrast-defined structure can be monitored in multiple visual field locations. Only under conditions that greatly advantaged contrast-defined motion, were observers able to discriminate the positional offset of shapes defined by either type of motion. When shapes from contrast-defined and luminance-defined motion were presented under comparable conditions, the positional accuracy of contrast-defined motion was found to be poorer than its luminance-defined counterpart. These results may explain some, but possibly not all, of the deficits found previously with second-order motion.

Cognition↗

The properties of the motion-detecting mechanisms mediating perceived direction in stochastic displays.

Previous studies [e.g. Baker & Hess, 1998. Vision Research, 38, 1211-1222] have shown that perceived direction in displays composed of multiple, limited-lifetime, Gabor micropatterns (G) is influenced by movement both at the fine spatial scale of the internal luminance modulation (first-order motion) and the coarse spatial scale of the Gaussian, contrast window (second-order motion). However it is presently indeterminate as to whether this pattern of results is indicative of the processes by which first-order and second-order motion signals interact within the visual system per se or those by which motion information, irrespective of how it is defined, is utilised across different spatial scales. To address this issue, and more generally the properties of the mechanisms that analyse motion in such displays, we employed stochastic motion sequences composed of either G, G added to a static carrier (G + C) or G multiplied with a carrier (G*C). Crucially G*C, unlike both G and G + C, micropatterns contain no net first-order motion and second-order motion only at the scale of the internal contrast modulation. For small displacements perceived direction in all cases showed a dependence on the internal sinusoidal spatial structure of the micropatterns and characteristic oscillations were typically observed, consistent with models in which first-order motion and second-order motion are encoded on the basis of similar low-level mechanisms. Importantly for larger displacements, and also when the internal spatial structure was randomised on successive exposures (so that motion at this spatial scale was unreliable), performance tended to be veridical for all types of micropattern, even though under these conditions displacements of the G*C micropatterns should have been invisible to current, low-level, motion-detecting schemes. This suggests that both low-level motion sensors and mechanisms utilising a different motion-detecting strategy such as high-level, attentive, feature-tracking may mediate perceptual judgements in stochastic displays.

Humans↗

Motion coherence affects human perception and pursuit similarly.

Pursuit and perception both require accurate information about the motion of objects. Recovering the motion of objects by integrating the motion of their components is a difficult visual task. Successful integration produces coherent global object motion, while a failure to integrate leaves the incoherent local motions of the components unlinked. We compared the ability of perception and pursuit to perform motion integration by measuring direction judgments and the concomitant eye-movement responses to line-figure parallelograms moving behind stationary rectangular apertures. The apertures were constructed such that only the line segments corresponding to the parallelogram's sides were visible; thus, recovering global motion required the integration of the local segment motion. We investigated several potential motion-integration rules by using stimuli with different object, vector-average, and line-segment terminator-motion directions. We used an oculometric decision rule to directly compare direction discrimination for pursuit and perception. For visible apertures, the percept was a coherent object, and both the pursuit and perceptual performance were close to the object-motion prediction. For invisible apertures, the percept was incoherently moving segments, and both the pursuit and perceptual performance were close to the terminator-motion prediction. Furthermore, both psychometric and oculometric direction thresholds were much higher for invisible apertures than for visible apertures. We constructed a model in which both perception and pursuit are driven by a shared motion-processing stage, with perception having an additional input from an independent static-processing stage. Model simulations were consistent with our perceptual and oculomotor data. Based on these results, we propose the use of pursuit as an objective and continuous measure of perceptual coherence. Our results support the view that pursuit and perception share a common motion-integration stage, perhaps within areas MT or MST.

Humans↗

Processing of first- and second-order motion signals by neurons in area MT of the macaque monkey.

Extrastriate cortical area MT is thought to process behaviorally important visual motion signals. Psychophysical studies suggest that visual motion signals may be analyzed by multiple mechanisms, a "first-order" one based on luminance, and a "second-order" one based upon higher level cues (e.g. contrast, flicker). Second-order motion is visible to human observers, but should be invisible to first-order motion sensors. To learn if area MT is involved in the analysis of second-order motion, we measured responses to first- and second-order gratings of single neurons in area MT (and in one experiment, in area V1) in anesthetized, paralyzed macaque monkeys. For each neuron, we measured directional and spatio-temporal tuning with conventional first-order gratings and with second-order gratings created by spatial modulation of the flicker rate of a random texture. A minority of MT and V1 neurons exhibited significant selectivity for direction or orientation of second-order gratings. In nearly all cells, response to second-order motion was weaker than response to first-order motion. MT cells with significant selectivity for second-order motion tended to be more responsive and more sensitive to luminance contrast, but were in other respects similar to the remaining MT neurons; they did not appear to represent a distinct subpopulation. For those cells selective for second-order motion, we found a correlation between the preferred directions of first- and second-order motion, and weak correlations in preferred spatial frequency. These cells preferred lower temporal frequencies for second-order motion than for first-order motion. A small proportion of MT cells seemed to remain selective and responsive for second-order motion. None of our small sample of V1 cells did. Cells in this small population, but not others, may perform "form-cue invariant" motion processing (Albright, 1992).

Animals↗

Neural correlates of implied motion.

Current views of the visual system assume that the primate brain analyses form and motion along largely independent pathways; they provide no insight into why form is sometimes interpreted as motion. In a series of psychophysical and electrophysiological experiments in humans and macaques, here we show that some form information is processed in the prototypical motion areas of the superior temporal sulcus (STS). First, we show that STS cells respond to dynamic Glass patterns, which contain no coherent motion but suggest a path of motion. Second, we show that when motion signals conflict with form signals suggesting a different path of motion, both humans and monkeys perceive motion in a compromised direction. This compromise also has a correlate in the responses of STS cells, which alter their direction preferences in the presence of conflicting implied motion information. We conclude that cells in the prototypical motion areas in the dorsal visual cortex process form that implies motion. Estimating motion by combining motion cues with form cues may be a strategy to deal with the complexities of motion perception in our natural environment.

Animals↗

Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation.

There has been some concern that organ motion, especially intra-fraction organ motion due to breathing, can negate the potential merit of intensity-modulated radiotherapy (IMRT). We wanted to find out whether this concern is justified. Specifically, we wanted to investigate whether IMRT delivery techniques with moving parts, e.g., with a multileaf collimator (MLC), are particularly sensitive to organ motion due to the interplay between organ motion and leaf motion. We also wanted to know if, and by how much, fractionation of the treatment can reduce the effects. We performed a statistical analysis and calculated the expected dose values and dose variances for volume elements of organs that move during the delivery of the IMRT. We looked at the overall influence of organ motion during the course of a fractionated treatment. A linear-quadratic model was used to consider fractionation effects. Furthermore, we developed software to simulate motion effects for IMRT delivery with an MLC, with compensators, and with a scanning beam. For the simulation we assumed a sinusoidal motion in an isocentric plane. We found that the expected dose value is independent of the treatment technique. It is just a weighted average over the path of motion of the dose distribution without motion. If the treatment is delivered in several fractions, the distribution of the dose around the expected value is close to a Gaussian. For a typical treatment with 30 fractions, the standard deviation is generally within 1% of the expected value for MLC delivery if one assumes a typical motion amplitude of 5 mm (1 cm peak to peak). The standard deviation is generally even smaller for the compensator but bigger for scanning beam delivery. For the latter it can be reduced through multiple deliveries ('paintings') of the same field. In conclusion, the main effect of organ motion in IMRT is an averaging of the dose distribution without motion over the path of the motion. This is the same as for treatments with conventional beams. Additional effects that are specific to the IMRT delivery technique appear to be relatively small, except for the scanning beam.

Computer Simulation↗

Sacroiliac motion for extreme hip positions. A fresh cadaver study.

STUDY DESIGN: This study placed fresh cadavers in different hip positions and obtained sacroiliac kinematics. The magnitudes and directions of angular and linear sacroiliac motion are reported. OBJECTIVES: To determine the three-dimensional motion at the left and right sacroiliac joints and to explore the mechanical structure of the sacroiliac joint. SUMMARY OF BACKGROUND DATA: Previous in vivo and in vitro studies have reported various amounts of motion at the sacroiliac joints, ranging from no motion to 18 degrees. The results of previous studies have typically not been reported as data in classic engineering terms, and three-dimensional analyses are sparse. Importantly, previous studies have not used external hip positions to elucidate the full range of sacroiliac motion. METHODS: Radiopaque markers were placed in the sacrum and each innominate bone before standardized performance of computed tomography scans at 3-mm intervals, with the fresh cadaver stabilized in the side-lying position on a specially constructed pallet. Computed tomography images were stored on magnetic tape, from which coordinates for centroids of the markers were obtained and subsequent mechanical analyses performed. The intersubchondral lines on the images were traced and reconstructed using computer technology to obtain the thickness of the intersubchondral joint space and the general configuration of the sacroiliac joints. RESULTS: The methods used in this study were validated. The largest amount of sacroiliac motion occurred in the sagittal plane (7 degrees on left and 8 degrees on the right, with a range of 3 degrees to 17 degrees). Definite trends in the direction of angular sacroiliac motion occurred with respect to both bilateral and reciprocal hip joint positions. The translation or linear motion of the posterior superior iliac spines with respect to the sacrum ranged from 4 to 8 mm. This motion tended to occur in all directions, with no detectable trends. The average intersubchondral thickness of the sacroiliac joint was 1.2 mm and the shape of the joint resembled that of an airplane propeller. CONCLUSIONS: Even though the subjects in this study were elderly, considerable angular and linear motion was in evidence. As such, it appears that extreme hip positions are necessary to elucidate full range of motion at the sacroiliac joint. The magnitude and direction of demonstrated sacroiliac motion appears to be sufficient to complement hip joint motion and influence motion at the lumbosacral junction and, thus, low back pain in both the direct and indirect sense.

Aged↗

Meta-analysis of normative cervical motion.

STUDY DESIGN: Meta-analysis of normative cervical range of motion literature performed by applying summary statistics to range of motion and reliability values reported among studies. OBJECTIVES: To identify reliable and valid methods for measuring active and passive cervical range of motion and to estimate normative values. SUMMARY OF BACKGROUND DATA: Range of motion studies use a variety of measuring instruments and statistical analyses, making it difficult to select the most suitable instruments, procedures, and normative values for clinical application. Reviews of the literature, being limited in scope, have not quantitatively synthesized the literature. METHODS: Range of motion and reliability data were grouped by technology and types of motion, then summarized by deriving means and variabilities. Clinical validity was assessed by examining discrepancies, variabilities, and correlations. Change in range of motion as a function of age was determined by comparing range of motion ratios (fourth:third and seventh:third decades). RESULTS: Nine technologies were identified. Overall, passive motion was greater than active motion, and range of motion decreased as age increased, with women exhibiting greater range of motion than men. Variations within each technology were as large as or larger than those between technologies, indicating that clinical procedures are as important as the accuracy and precision of the technology itself. Reliability has not been adequately tested for the majority of technologies. CONCLUSIONS: Clinical procedures appear to be as important as accuracy and precision in determining the reported range of motion values. Further research is needed to establish a gold standard for normative values and to identify an instrument that is reliable for all motions.

Adult↗

Intervertebral motion between flexion and extension in asymptomatic individuals.

STUDY DESIGN: Measure and analyze variation in intervertebral motion in asymptomatic subjects. OBJECTIVES: Gain further insight into intervertebral motion during flexion and extension in asymptomatic individuals, identify factors that contribute to variation in motion, and establish a quantitative database using a clinically practical imaging tool. SUMMARY OF BACKGROUND DATA: Several authors have reported on normal values for intervertebral motion during flexion and extension of the cervical spine. However, the sources of the wide variations in intervertebral motion are poorly understood. METHODS: Fluoroscopic images of the cervical spine in maximum flexion and extension were analyzed for 140 asymptomatic volunteers using a validated and clinically applicable image analysis system. Several independent variables were analyzed for their contribution to variation in motion. The dependent variables studied included sagittal plane rotation and translation, and displacements between vertebrae measured at the anterior and posterior aspects of each motion segment. RESULTS: There was considerable variation in measured intervertebral motion. Intervertebral level and total gross rotation between C2 and C6 significantly affected all measures of intervertebral motion. The intervertebral motion measures were all interrelated. After adjusting for differences in gross motion between C2 and C6, intervertebral levels and the three displacement measures could be used to explain almost 90% of the variation in sagittal plane intervertebral rotations. In addition, the data suggest that currently accepted clinical guidelines for shear should be raised at all levels except C6-C7. CONCLUSIONS: A database describing intervertebral motion in asymptomatic subjects representing both sexes and a wide age range was established that should aid in interpreting intervertebral motion in patients. Evaluating various aspects of intervertebral motion may improve the clinical efficacy of radiographic flexion-extension studies of the cervical spine.

Adolescent↗

Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography based on 3-D image registration.

Image processing was used as a fundamental tool to derive motion information from magnetic resonance (MR) images, which was fed back into prospective respiratory motion correction during subsequent data acquisition to improve image quality in coronary MR angiography (CMRA) scans. This reduces motion artifacts in the images and, in addition, enables the usage of a broader gating window than commonly used today to increase the scan efficiency. The aim of the study reported in this paper was to find a suitable motion model to be used for respiratory motion correction in cardiac imaging and to develop a calibration procedure to adapt the motion model to the individual patient. At first, the performance of three motion models [one-dimensional translation in feet-head (FH) direction, three-dimensional (3-D) translation, and 3-D affine transformation] was tested in a small volunteer study. An elastic image registration algorithm was applied to 3-D MR images of the coronary vessels obtained at different respiratory levels. A strong intersubject variability was observed. The 3-D translation and affine transformation model were found to be superior over the conventional FH translation model used today. Furthermore, a new approach is presented, which utilizes a fast model-based image registration to extract motion information from time series of low-resolution 3-D MR images, which reflects the respiratory motion of the heart. The registration is based on a selectable global 3-D motion model (translation, rigid, or affine transformation). All 3-D MR images were registered with respect to end expiration. The resulting time series of model parameters were analyzed in combination with additionally acquired motion information from a diaphragmatic MR pencil-beam navigator to calibrate the respiratory motion model. To demonstrate the potential of a calibrated motion model for prospective motion correction in coronary imaging, the approach was tested in CMRA examinations in five volunteers.

Adult↗

Contributions of human long-wave and middle-wave cones to motion detection.

1. It has been suggested that motion may be best detected by the luminance mechanism. If this is the most sensitive mechanism, motion thresholds may be used to isolate the luminance mechanism and study its properties. 2. A moving (1 cycle deg-1), vertical, heterochromatic (red-plus-green), foveal grating was presented on a bright yellow (577 nm wavelength) field. Detection and motion (direction identification: left versus right) thresholds were measured for different amplitude ratios of the red and green components spatially summed in phase or in antiphase. Threshold contours plotted in cone-contrast co-ordinates (L',M') for the long-wave (L) and middle-wave (M) cones, revealed two motion mechanisms: a luminance mechanism that responds to a weighted sum of L and M contrasts, and a spectrally opponent mechanism that responds to a weighted difference. 3. Detection and motion thresholds, measured at 1-4 Hz, were identical for luminance gratings, having equal cone contrasts, L' and M', of the same sign. For chromatic gratings, with L' and M' of opposite sign, motion thresholds were higher than detection thresholds. A red-green hue mechanism may mediate chromatic detection, and a separate spectrally opponent motion mechanism may mediate motion. 4. The red-green hue mechanism was assessed from 1 to 15 Hz with an explicit hue criterion. The detection contour had a constant slope of one, implying equal L' and M' contributions of opposite sign. For motion identification, L' and M' contributed equally at 1 Hz, but the M' contribution was attenuated at higher velocities. 5. The cone-contrast metric provides a physiologically relevant comparison of sensitivities of the two motion mechanisms. At 1 Hz, the spectrally opponent motion mechanism is approximately 4 times more sensitive than the luminance mechanism. As temporal frequency is increased, the relative sensitivities change so that the luminance mechanism is more sensitive above 9 Hz. 6. The less sensitive motion mechanism was isolated with a quadrature phase protocol, using a pair of heterochromatic red-plus-green gratings, counterphase flickering in spatial and temporal quadrature phase with respect to each other. One grating was set slightly suprathreshold and oriented in cone contrast (L',M') so as to potentiate a single motion mechanism, the sensitivity of which was probed with the second grating, which was varied in (L',M'). This allowed us to measure the motion detection contour of the less sensitive luminance mechanism at low velocities.(ABSTRACT TRUNCATED AT 400 WORDS)

Color↗

Kinematic analysis and simulation of vertebral motion under static load-part I: kinematic analysis.

The paper presents the kinematic analysis of motion segments of ten, humanlumbar spines. In order to achieve this objective, a spine fixture and a linkage transducer were designed. The spine fixture is capable of holding the motion segment in a prescribed plane of loading. With the designed fixture it becomes possible to apply three types of shear loads, and three types of bending loads. In addition, if desired, a compressive preload may be applied to a motion segment. The linkage transducer consists of six rotary potentiometers connected by seven rigid links. The transducer is capable of measuring all possible components of vertebral motion. The motion data in the motion segments of ten lumbar spine were collected under the influence of combined shear and bending loads applied in an incremental manner. Maximum shear load was 35.6 N and maximum bending load was 6780 N. mm. The motion segments did not show any appreciable difference in their motion beyond these loads. The motion segments were not subjected to any compressive preload. The range of motion data were collected in twelve loading planes 15 deg. apart. The characteristic vertebral motion may be described in terms of range of motion, its components, and the parameters associated with the screw motion. The paper presents data in the chart form to describe the kinematic characteristics of the lumbar motion segment.

Humans↗

Motion mechanisms in macaque MT.

The macaque middle temporal area (MT) is exquisitely sensitive to visual motion and there is a large amount of evidence that neural activity in MT is tightly correlated with the perception of motion. The mechanisms by which MT neurons achieve their directional selectivity, however, have received considerably less attention. We investigated the motion-energy model as a description of motion mechanisms in macaque MT. We first confirmed one of the predictions of the motion-energy model; macaques-just like humans-perceive a reversed direction of motion when a stimulus reverses contrast with every displacement (reverse-phi). This reversal of perceived direction had a clear correlate in the neural responses of MT cells, which were predictive of the monkey's behavioral decisions. Second, we investigated how multiple motion-energy components are combined. Psychophysical data have been used to argue that motion-energy components representing opposite directions are subtracted from each other. Our data show, however, that the interactions among motion-energy components are more complex. In particular, we found that the influence of a given component on the response to a stimulus consisting of multiple components depends on factors other than the response to that component alone. This suggests that there are subthreshold nonlinear interactions among multiple motion-energy components; these could take place within MT or in earlier stages of the motion network such as V1. We propose a model that captures the complexity of these component interactions by means of a competitive interaction among the components. This provides a better description of the MT responses than the subtractive motion opponency envisaged in the motion-energy model, even when the latter is combined with a gain-control mechanism. The competitive interaction extends the dynamic range of the cells and allows them to provide information on more subtle changes in motion patterns, including changes that are not purely directional.

Animals↗