Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Inhalation Spacers”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Inhaled budesonide for chronic wheezing under 18 months of age.

The role of budesonide in controlling chest symptoms in infants was assessed. It was administered from a metered dose inhaler into a large volume spacer (Nebuhaler) with attached Laerdal mask. Twenty nine infants were recruited into a double blind crossover trial. Five defaulted. The remaining 24 (mean age 11 months) were assessed for the tolerance of the device, adverse effects, treatment failures, parental opinion, and daily symptom and treatment records. Twenty tolerated the modified Nebuhaler. One developed meningitis on placebo. Two experienced exacerbations on placebo. Eleven of 18 parents whose children completed the maximum treatment preferred budesonide to placebo and one preferred placebo. Mean symptom scores on budesonide were better than on placebo for the 15 children with complete symptom records. Fewer bronchodilator doses were used while taking budesonide. Our findings indicate that budesonide given in this way is an effective treatment for infants who may need prophylaxis for their wheezing.

Administration, Inhalation↗

A randomized, double-blind dose reduction study to compare the minimal effective dose of budesonide Turbuhaler and fluticasone propionate Diskhaler.

BACKGROUND: New inhaled glucocorticosteroids and inhalers are being developed. Their clinical equipotency is difficult to assess and is often discussed. OBJECTIVE: This study was carried out to compare the effect of budesonide Turbuhaler and fluticasone propionate (FP) Diskhaler in a dose reduction study in children (ages 5 to 16 years) with asthma. METHODS: Children treated with budesonide administered through a pressurized metered-dose inhaler with a large volume spacer had their budesonide dose gradually reduced to define the minimal effective dose with this delivery system. After this period, 217 children were randomly allocated to treatment with half the dose of either budesonide Turbukaler or FP Diskhaler for 5 weeks in a double-blind trial. If no deterioration in asthma control was seen, the dose was further reduced by 50% at 5-week intervals until deterioration in asthma control was seen. Throughout the study, morning and evening peak expiratory flow, symptoms, and use of rescue beta 2-agonist were recorded in diaries. Lung function tests and a standardized exercise test were performed at the clinic at the end of each treatment period. Urine cortisol excretion (24 hours) was measured before and after the first 5-week treatment period. Standardized criteria for deterioration in asthma control, based on diary card variables and exercise testing, were used to determine the minimal effective dose for each patient; and from this, the number of dose reduction steps was calculated. RESULTS: No statistically significant difference was seen in number of dose reduction steps from baseline or in minimal effective dose between the two treatments; mean reduction was 1.59 dose steps for budesonide Turbuhaler and 1.65 dose steps for FP Diskhaler (p = 0.52), and minimal effective dose was 188 micrograms for budesonide Turbuhaler and 180 micrograms for FP Diskhaler. After these dose reductions, the same level of asthma control was observed in the budesonide Turbuhaler and FP Diskhaler groups. Furthermore, no statistically significant differences between the two inhaler-drug combinations were seen in daytime or nighttime symptoms, morning and evening peak expiratory flow, use of rescue beta 2-agonist, lung functions at the clinic, exercise-induced fall in lung function, or 24-hour urinary cortisol excretion during the first 5-week period. CONCLUSION: Microgram for microgram, budesonide Turbuhaler and FP Diskhaler are equally effective in treatment of children with moderate asthma.

Administration, Inhalation↗

Special problems in aerosol delivery: neonatal and pediatric considerations.

Identification of the determinants of efficient aerosol delivery and the specific challenges of aerosol delivery to infants and children can facilitate a systematic approach to optimize aerosol delivery to this population. There are inherent anatomical, physiologic, pathophysiologic, and technical limitations of aerosol efficiency in infants and young children. Nevertheless, one can enhance aerosol efficiency through application of sound principles of aerosol delivery and by exerting control over factors that are amenable to intervention. Improvements in aerosol formulations and delivery systems are being made that will enhance efficiency, decrease risk, and reduce waste and cost. Attention to aerosol particle size (1-3 microm mass median aerodynamic diameter and geometric standard deviation < 2 microm), and the concentration of this respirable particle fraction produced by an aerosol system may enhance delivery through endotracheal tubes and to the lower respiratory tract in infants and children with low V(T) and low inspiratory rates. Attention to the choice of delivery system and to details of proper MDI technique (shaking, priming, immediate actuation, and avoiding multiple actuations prior to inhalation), choice of the aerosol spacer and patient interface (type of face mask, endotracheal tube, mouthpiece), spacer cleaning, and consideration of the medicine to be aerosolized (solution or suspension, viscosity) permit adjustment of the aerosol regimen to optimize delivery. All the patient-related, system-related, and operator-dependent considerations combined can greatly impact aerosol delivery efficacy and improve therapeutic response. Therefore, education and motivation of medical personnel, parents and caregivers, and patients regarding factors that influence aerosol efficiency and teaching of proper technique must be prioritized in order to improve aerosol delivery. Aerosol therapy to all patients, especially infants and young children, would be well served if we had a clear understanding of the efficiency and functional differences among the various drugs and devices. These are substantive issues with daily therapeutic impact that have received increasingly outspoken concern over the past decade by aerosol scientists and clinicians. These issues must be given due attention by drug and device manufacturers as well as by regulatory agencies. The medication, the device, and the conditions under which they are tested must be considered together and studied as thoroughly as the medications themselves with respect to total output and particle size distribution. As noted by Bisgaard, medication dose recommendations are useless unless the device and technique used are specified. Medication dose recommendation could be facilitated by setting equivalent standards for generic and brand-name medications and devices. In addition, standardization of in vitro models with better replicas of infants' and children's anatomy (oropharynx, upper airways), and better in vitro lung models, plus utilization of realistic breathing patterns of infants and children will improve in vitro prediction of the in vivo dose delivered to lower airways. This would greatly facilitate selection of delivery systems under specific circumstances for infants and children of various ages). Safety profile, therapeutic efficacy, and efficiency of aerosolized medications delivered to infants and children need to be rigorously studied. This is particularly true for medications with potentially great benefit but possible adverse effects, such as inhaled glucocorticoid therapy in extremely premature infants. Common sense, ethics, and due respect for the same high standard of approval requirements of adults and older children should motivate further research in understanding and improving aerosol delivery in infants and young children.

Aerosols↗

Significant variability in response to inhaled corticosteroids for persistent asthma.

BACKGROUND: A clinical model is needed to compare inhaled corticosteroids (ICSs) with respect to efficacy. OBJECTIVE: The purpose of this investigation was to compare the relative beneficial and systemic effects in a dose-response relationship for 2 ICSs. METHODS: A 24-week, parallel, open-label, multicenter trial examined the benefit-risk ratio of 2 ICSs in persistent asthma. Benefit was assessed by improvements in FEV(1) and PC(20); risk was assessed by overnight plasma cortisol suppression. Thirty subjects were randomized to either beclomethasone dipropionate (BDP) 168, 672, and 1344 microg/day (n = 15) or fluticasone propionate (FP) 88, 352, and 704 microg/day (n = 15), both administered by means of a metered dose inhaler (MDI) with chlorofluorocarbon propellant via a spacer, in 3 consecutive 6-week intervals; this was followed by 3 weeks of FP dry powder inhaler (DPI) 2000 microg/day. RESULTS: Maximum FEV(1) response occurred with the low dose for FP-MDI and the medium dose for BDP-MDI and was not further increased by treatment with FP-DPI. Near-maximum methacholine PC(20) improvement occurred with the low dose for FP-MDI and the medium dose for BDP-MDI. Both BDP-MDI and FP-MDI caused dose-dependent cortisol suppression. Responsiveness to ICS treatment was found to vary markedly among subjects. Good (>15%) FEV(1) response, in contrast to poor (<5%) response, was found to be associated with high exhaled nitric oxide (median, 17.6 vs 11.1 ppb), high bronchodilator reversibility (25.2% vs 8.8%), and a low FEV(1)/forced vital capacity ratio (0.63 vs 0.73) before treatment. Excellent (>3 doubling dilutions) improvement in PC(20), in contrast to poor (<1 doubling dilution) improvement, was found to be associated with high sputum eosinophil levels (3.4% vs 0.1%) and older age at onset of asthma (age, 20-29 years vs <10 years). CONCLUSIONS: Near-maximal FEV(1) and PC(20) effects occurred with low-medium dose for both ICSs in the subjects studied. High-dose ICS therapy did not significantly increase the efficacy measures that were evaluated, but it did increase the systemic effect measure, overnight cortisol secretion. Significant intersubject variability in response occurred with both ICSs. It is possible that higher doses of ICSs are necessary to manage more severe patients or to achieve goals of therapy not evaluated in this study, such as prevention of asthma exacerbations.

Administration, Inhalation↗

In vitro comparison of salbutamol hydrofluoroalkane (Airomir) metered dose inhaler aerosols inhaled during pediatric tidal breathing from five valved holding chambers.

Amounts of salbutamol delivered from chlorofluorocarbon (CFC)-free metered dose inhalers (MDIs) (Airomir; 3M, St. Paul, MN) in particle sizes appropriate for inhalational treatment with five common holding chambers (NES [or Nebuchamber] spacer [Astra Draco AB, Lund, Sweden], AeroChamber [Trudell Medical, London, Ontario, Canada], OptiChamber [Health-scan Products, Cedar Grove, NJ], Vent170 spacer [Nordac Design, Waterloo, Ontario, Canada], and E-Z Spacer [WE Pharmaceuticals, Ramona, CA]) when used under simulated pediatric tidal breathing conditions were determined. Five devices of each type were tested with Airomir hydrofluoroalkane (HFA) inhalers (100 micrograms of salbutamol). Each device was connected to face replicas representative of 7-month-old (infant) and 2-year-old (toddler) children, and aerosol was also inhaled into an Andersen cascade impactor (Graseby Andersen, Smyrna, GA) using a valve system and simulated tidal breathing patterns representative of children of these ages. Amounts of drug inhaled in fine particles with the HFA formulation are significantly less (up to 46% less) with the E-Z Spacer (P < 0.01) compared with amounts inhaled in previous studies with the CFC formulation but are nearly the same with other holding chamber types (e.g., differing by < 6% for the AeroChamber). With the HFA formulation, the metal NES spacer delivered significantly more salbutamol in fine particles (P < 0.01) than any of the other holding chambers. Amounts of salbutamol inhaled in fine particles during pediatric tidal breathing from valved holding chambers with Airomir varies considerably between holding chamber types.

Aerosols↗

The effects of static charge in spacer devices on glucocorticosteroid aerosol deposition in asthmatic patients.

Electrostatic charge in plastic spacer devices has been shown in vitro to reduce delivery of asthma medications intended for inhalation, but the effect of static charge on in vivo drug deposition is unknown. A six-way randomized crossover study was conducted in 10 mild asthmatic patients. Two plastic spacers (Nebuhaler and Volumatic) and one metal spacer (Nebuchamber) were tested. The spacers were used either "primed" or "unprimed". Priming was performed by firing 20 doses of placebo aerosol into a new spacer, hence coating the inner surface with surfactant and minimizing static charge. Unprimed spacers were new and were not treated. Pressurized aerosol canisters delivering budesonide (200 microg Pulmicort) were radiolabelled with the radionuclide 99mTc and lung deposition was measured by gamma scintigraphy. The radiolabel was shown to be a valid marker for the drug substance prior to the clinical phase of the study. Priming significantly increased mean whole lung deposition following inhalation from plastic spacers (Nebuhaler primed 37.7% and unprimed 26.7%, p=0.01; Volumatic primed 32.0% and unprimed 22.1%, p=0.02). Priming had no effect on the mean whole lung deposition following inhalation from the Nebuchamber (primed 33.5% and unprimed 32.9%). Lung deposition in vivo from plastic spacer devices will vary according to the electrostatic charge on the spacer walls. Priming reduces retention of drug on plastic spacer devices and increases lung deposition. Metal spacers are not susceptible to static charge, which should result in more predictable lung deposition.

Administration, Inhalation↗

Bronchodilators for the prevention and treatment of chronic lung disease in preterm infants.

BACKGROUND: Chronic lung disease (CLD) occurs frequently in preterm infants (< 37 weeks gestational age) and has a multifactorial etiology. Bronchodilators have the potential effect of dilating small airways with muscle hypertrophy. Increase in compliance and tidal volume and decrease in pulmonary resistance have been documented with use of bronchodilators in short term studies of pulmonary mechanics in infants with CLD. Therefore it is possible that bronchodilators might have a role in the prevention and treatment of CLD. OBJECTIVES: To evaluate the effect of bronchodilators, given prophylactically or as treatment for chronic lung disease, on mortality and other complications of preterm births. SEARCH STRATEGY: The search strategy used to identify studies was according to the guidelines of the Cochrane Neonatal Review Group. Searches were made of MEDLINE 1966 to December 2000, EMBASE 1980 to January 2001, CINAHL 1982 to December 2000, the Cochrane Library Issue 1, 2001, personal files and reference lists of identified trials. The following terms were used: bronchopulmonary dysplasia, chronic lung disease, bronchodilator agents, adrenergic agents, anticholinergic agents, albuterol, aminophylline, atropine, caffeine, clenbuterol, cromakalim, ephedrine, epinephrine, fenoterol, hexoprenaline, ipratropium, isoetharine, isoproterenol, orciprenaline, procaterol, terbutaline, theophylline, tretoquinol. LIMITS: newborn, infant; human, clinical trial or controlled clinical trial, meta analysis, multicenter study or randomised controlled trial. No language restrictions were applied. SELECTION CRITERIA: Randomised controlled clinical trials involving preterm infants. Initiation of bronchodilator therapy had to occur within two weeks of birth for prevention of CLD. For treatment of CLD treatment should have been initiated before discharge from the neonatal unit. The intervention had to include the randomised administration of a bronchodilator either by nebulisation, metered dose inhaler with or without a spacer device, intravenously or orally, versus placebo or no intervention. Eligible studies had to include at least one of the following outcomes: mortality, CLD at 28 days or at 36 weeks corrected GA, number of days on oxygen, number of days on ventilator, patent ductus arteriosus (PDA), pulmonary interstitial emphysema (PIE), pneumothorax, any grade of intraventricular haemorrhage, necrotizing enterocolitis (NEC), sepsis and adverse effects of bronchodilators. DATA COLLECTION AND ANALYSIS: We used the standard method for the Cochrane Collaboration as described in the Cochrane Collaboration handbook. Two investigators (GN, AO) extracted and assessed all data for each study. Any disagreement was resolved by discussion. Relative risk (RR) and risk difference (RD) with 95% confidence intervals (CI) are reported for dichotomous outcomes and mean difference (WMD) for continuous data. MAIN RESULTS: One eligible study was found dealing with prevention of CLD; this study used salbutamol and enrolled 173 infants. No eligible studies were found dealing with treatment of CLD. Prophylaxis with salbutamol did not show a statistically significant difference in mortality [RR 1.08 (95% CI 0.50, 2.31); RD 0.01 (95% CI -0.09, 0.11)], CLD (mild, moderate or severe) [RR 1.03 (95% CI 0.78, 1.37); RD 0.02 (95% CI -0.13, 0.17)], need for iv dexamethasone [RR 0.77 (95% CI 0.49, 1.19); RD -0.08 (95% CI -0.22, 0.05)], respiratory infections [RR 0.61 (95% CI 0.27, 1.39); RD -0.06 (95% CI -0.16, 0.04)] or positive blood culture [RR 1.06 (95% CI 0.54, 2.06); RD 0.01 (95% CI -0.10, 0.12)]. There was no statistically significant difference in duration of ventilatory support [MD -1.63 days (95% CI -5.63, 2.37)], duration of oxygen supply [MD -2.82 days (95% CI -11.91, 6.27)] or age of weaning from respiratory support (defined as assisted ventilation or oxygen supplementation) [MD -2.87 days (95% CI -11.28, 5.54)]. No side effects due to salbutamol were commented on in this study. REVIEWER'S CONCLUSIONS: There are insufficient data to reliably assess the use of salbutamol for the prevention of CLD. Further clinical trials are necessary to assess the role of salbutamol or other bronchodilator agents in prophylaxis or treatment of CLD.

Bronchodilator Agents↗

Delivery of micronized budesonide suspension by metered dose inhaler and jet nebulizer into a neonatal ventilator circuit.

We compared the delivery of a micronized suspension of budesonide by a metered dose inhaler (MDI) with two different spacers (Aerochamber and Aerovent) and by two jet nebulizers (MAD2 and Ultravent) to a ventilated neonatal test-lung using a standard neonatal ventilator circuit. The combination of MDI and Aerochamber was significantly better at delivering budesonide to a filter in front of the test lung (14.2% of aerosolized dose) than were either the MDI and Aerovent (3.6%) or the Ultravent or MAD2 jet nebulizers (0.02% and 0.68% of initial reservoir dose). Of the droplets emerging from the MDI, Aerochamber, and ET tube, 18% of the initial dose was in droplets less than 4.7 microns. Assuming that the test-lung model accurately reflects in vivo deposition, the combination of MDI and Aerochamber appears to be an extremely effective way of delivering budesonide aerosol to ventilated newborn infants.

Aerosols↗

[Role of Bronchodual in the long-term treatment of asthma in children].

Bronchodual is a combination of two bronchodilators, a beta-2 adrenergic substance (fenoterol, 50 micrograms per dose), and an anticholinergic substance (ipratropium bromide, 20 micrograms per dose), administered by metered aerosol. According to different studies carried out with adults and children, the bronchodilating action of this combination is greatly superior to that obtained with each substance individually; the beta-2 adrenergic substance can be spared; its action is longer and involves a decrease in the number of drug intake and lastly its tolerance is excellent. A French multicentre study was performed with 74 children (7 to 15 years old, mean: 11.8 +/- 2.6 years), 53 boys and 21 girls with allergic or non-allergic asthma: 41 children presented a moderate asthma (one crisis per month) and 33 children moderately severe asthma (one crisis per week). These children had been given no corticosteroid therapy (per os or inhaled) for at least 15 days, their usual long-term treatment (cromoglycate, anti H1, theophylline LP, antibiotics) was given as normal. Their FVC was > or = 80% of predicted values and they presented an intercritical airway obstruction. Hypoxemia was noted in 41.2% of the children. A reversibility test was performed with Bronchodual: 68 of 74 children (i.e. 91.9%) were responders, ie after two doses of Bronchodual at least one of the FEFs had increased by at least 15% when compared with the initial values. The responders were given a 2 month treatment with two inhalations 3 times/day with a spacer. Fifty-seven patients were considered for the final evaluation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

The incidence of airflow obstruction in bronchial carcinoma, its relation to breathlessness, and response to bronchodilator therapy.

Breathlessness is a common symptom in patients with primary bronchial carcinoma and is often not well-controlled. Most patients are ex- or current smokers, and therefore are at high risk for co-existing chronic obstructive pulmonary disease (COPD). The incidence of airflow obstruction in patients with bronchial carcinoma, its relation to breathlessness, and response to bronchodilator therapy was examined prospectively. Fifty-seven consecutive patients attending our outpatient clinic with bronchial carcinoma diagnosed in the preceding 12 months were studied (22 female, 35 male, mean age 68.4 years). Spirometry was performed and breathlessness rated. Those with airflow obstruction (FEV1:FVC < 65% and FEV1 < 70% predicted) and who judged themselves to have moderate or severe breathlessness, were offered a trial of bronchodilator therapy. The response to regular inhaled fenoterol and ipratropium bromide by metered dose inhaler (MDI) and large volume spacer, and to regular nebulized salbutamol and ipratropium bromide was assessed by home peak flow recordings, spirometry and two subjective scores: (a) rating of breathlessness on a simple four-point scale, and (b) activity score of the St George's Respiratory Questionnaire. There was very strong association between airflow obstruction and breathlessness. Twenty-eight patients (49%) had airflow obstruction, and we had breathlessness ratings on 26 of these patients of whom 18 (69%) had rated it as moderate or severe. Only four of the patients with airflow obstruction and breathlessness were using bronchodilator therapy. There was no significant difference in the mean age, time from diagnosis, tumour site, or smoking history between the groups with, and without, airflow obstruction. There was no association between cell type and the presence of airflow obstruction.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Aerosol characterization of three corticosteroid metered dose inhalers with volumatic holding chambers and metered dose inhalers alone at two inspiratory flow rates.

Inhaled corticosteroids are first-choice drugs in the treatment of chronic asthma. A metered dose inhaler (MDI) equipped with a spacer device is easier to use for patients with a poor inhalatory technique; it favors a reduction in the size of the particles delivered to the patient and thus a reduction in the incidence of local and systemic side effects of these drugs. The aim of this study was to determine the particle characteristics of fluticasone propionate (FP), flunisolide (FLUN), and beclomethasone dipropionate (BDP), each administered at a rate of 250 micrograms per puff and at inspiratory flow rates of 30 and 60 L/min in vitro, to estimate the particle characteristics of these drugs aspirated via an MDI alone and via a large-volume holding chamber (Volumatic). Compared with the MDI alone, at 30 L/min, the Volumatic (Glaxo Wellcome, Ware, UK) significantly reduced the mass median aerodynamic diameter (MMAD) and increased the fine particles (< 5 microns and < 2 microns) generated by all three drugs. At 60 L/min, the MMAD increased and the generation of fine particles decreased with both devices. These data suggest that the inspiratory flow applied by means of the devices may be a determinant for the deposition of the drug in the lower airways in that by increasing the inspiratory flow, the MMAD increases and the percentage of fine particles decreases, probably because of the reaggregation favored by the higher flows.

Aerosols↗

Determinants of aerosolized albuterol delivery to mechanically ventilated infants.

An in-vitro lung model and a volume ventilator were used to evaluate the delivery of aerosolized albuterol through an infant ventilator circuit. We compared the following: continuous nebulization (CNA) and intermittent nebulization (INA); various nebulizer gas flows, 5.0, 6.5,and 8.0 L/min; and duty cycle of 33% and 50%. The efficiency and consistency of aerosol delivery by metered-dose inhaler (MDI) with four different spacer devices and by nebulizer positioned at the manifold and at the same position as the MDI were also evaluated. A volume ventilator (Servo 900B) was used with settings selected to reflect those of a moderately to severely ill 4-kg infant. A 3.5-mm endotracheal tube was used in all experiments. A specific type of nebulizer used (Airlife Misty Neb; Baxter; Valencia, Calif) and several spacers were studied (Aerochamber and Aerovent, Monaghan Medical Corporation in Plattsburgh, NY [corrected]; ACE, Diemolding Healthcare Division in Canastota, NY [corrected]; and an in-line MDI adapter, Instrumentation Industries Inc, Pittsburgh). CNA delivered significantly more aerosol to the lung model (4.8 +/- 0.6% of the starting dose) than INA (3.8 +/- 0.3%; p<0.01). There was a significant stepwise decrease in aerosol delivery with increasing nebulizer flow (4.8 +/- 1.3% at 5.0 L/min; 3.7 +/- 1.1% at 6.5 L/min; and 2.7 +/- 1.1% at 8.0 L/min). Increasing duty cycle did not significantly affeet delivery. Overall the spacers with MDI were more efficient than the nebulizer in either position delivering about twice the percentage of the starting dose than the nebulizers. All modes of delivery, except the Aerochamber, demonstrated a marked degree of variability. Most of the starting dose of albuterol either remained in the nebulizer (30.4 +/- 6.0% at 5.0 L/min and 25.3 +/- 4.1% at 8.0 L/min) or was deposited in the inspiratory tubing (34.7 +/- 0.7% at 5.0 L/min and 43.7+/- 4.9% at 8.0 L/min) in our system. In conclusion, we have confirmed that aerosol delivery depends on the mode of delivery and the operating conditions. Although delivery with an MDI and spacer is more efficient than a nebulizer, both methods may produce high variability depending on the method or spacer used.

Aerosols↗

Equivalence of continuous flow nebulizer and metered-dose inhaler with reservoir bag for treatment of acute airflow obstruction.

Traditionally, patients with acute airflow obstruction are treated with bronchodilator aerosols delivered by continuous flow nebulizers. While bronchodilator administration with the metered dose inhaler (MDI) and reservoir or spacer attachment is as effective as administration with the nebulizer in most settings, the former has not been widely accepted for treatment of acute airway obstruction in the emergency room. We compared the efficacy of the continuous flow nebulizer to that of the MDI with InspirEase (reservoir spacer) in 75 patients (45 men and 30 women), ages 18-73 (chi 44 years) who presented to the emergency room with acute asthma and COPD. Subjects in each group (22 COPD and 53 asthma) were randomly assigned to treatment with three puffs of metaproterenol (0.65 mg/puff) via the MDI with InspirEase plus nebulizer with placebo, or placebo MDI with InspirEase plus nebulizer with 15 mg metaproterenol in double blind fashion. Either treatment was given three times at 30 min intervals. The FEV1 and dyspnea scores according to the Borg scale were measured at baseline, 30 min after the first treatment, and 30 min after the third. There was no significant outcome difference between the two treatments in either diagnostic group. There also was no significant outcome difference for patients with baseline FEV1 less than 0.9L. Serum theophylline levels, the need for concomitant therapy with corticosteroids, or additional emergency room therapy after the study, hospitalizations and treatment side effects did not differ between treatment groups. We conclude that there is no demonstrable advantage of a continuous flow nebulizer over an MDI with InspirEase for the treatment of acute airflow obstruction.

Adult↗

[Asthma in children below 5 years of age: diagnosis and treatment].

Asthma is the most frequent chronic disease in pediatrics and the increase in its prevalence is a major public health problem. Diagnosis may be difficult in the young child, symptomatology most often occurring following a viral infection. It is important not to ignore a foreign body in the airways or fibrocystic disease and asthma remains, particularly in infants, a diagnosis of elimination. Misdiagnosis or insufficient treatment of asthma may risk the development of irreversible histological lesions and also could compromise pulmonary growth and the child's lung reserve. Spacer devices and nebulisers enable inhaled therapy to be administered to very young children. The value of early diagnosis is to institute appropriate treatment notably in severe asthma with inhaled corticosteroid therapy, the aim being to reduce remodelling lesions of the airways. The minimal effective dose should be defined to minimalize side-effects. The treatment of asthma is not restricted to pharmacotherapy: attempts should be made to reduce intercurrent viral infections, domestic pollution (including smoking) and allergenic concentrations. However, as for all chronic diseases, the clinician will encounter poor compliance. The work of education and support of health professionals is fundamental to the management of asthma.

Asthma↗

[Asthma and the child below 5 years of age: diagnosis and treatment].

Asthma is the most frequent chronic disease in pediatrics and the increase in its prevalence is a major public health problem. Diagnosis may be difficult in the young child, symptomatology most often occurring following a viral infection. It is important not to ignore a foreign body in the airways or fibrocystic disease and asthma remains, particularly in infants, a diagnosis of elimination. Misdiagnosis or insufficient treatment of asthma may risk the development of irreversible histological lesions and also could compromise pulmonary growth and the child's lung reserve. Spacer devices and nebulisers enable inhaled therapy to be administered to very young children. The value of early diagnosis is to institute appropriate treatment notably in severe asthma with inhaled corticosteroid therapy, the aim being to reduce remodelling lesions of the airways. The minimal effective dose should be defined to minimalise side-effects. The treatment of asthma is not restricted to pharmacotherapy: attempts should be made to reduce intercurrent viral infections, domestic pollution (including smoking) and allergenic concentrations. However, as for all chronic diseases, the clinician will encounter poor compliance. The work of education and support of health professionals is fundamental to the management of asthma.

Age Factors↗

Postoperative administration of aerosolized medications: Part I--The basics.

Based on the content of this article, the reader should be able to (1) describe the advantages and disadvantages of instituting drug delivery using the inhalation route; (2) verbalize factors that impact on aerosol deposition within the lung; (3) list the various types of aerosol-generating devices; (4) describe the benefits of incorporating a spacer device with the metered dose inhaler; and (5) identify and be familiar with the major categories of aerosolizable agents.

Aerosols↗

[Survey about Barcelona Health Center General Practitioners' therapeutic attitude and control criteria of patients with respiratory chronic diseases].

OBJECTIVE: To determine the level of conditions to be found in general medicine in the Basic Health Areas (BHA) of Barcelona and metropolitan area, with respect to the diagnosis and control of asthma and POCD. Also, to determine the level of clinical knowledge of the doctors in terms of diagnosis, control and treatment of these pathologies. DESIGN: Cross-sectional study by questionnaire. SETTING: The BHA's of Barcelona and metropolitan area. PARTICIPANTS: General practitioners (GP's) within the above-mentioned BHA's. INTERVENTIONS: Questionnaire consisting of 20 questions and divided into 4 parts: personal information, control and health education, diagnosis and bronchodilatory treatment (BD). MEASUREMENTS AND MAIN RESULTS: 43% of the GP's had a Peak-Flow Metre (PFM), while 21% had never had one. 36% of the doctors required a respiratory functions test (RFT) of all their patients. 15% always prescribed the spacer chamber (SC) when giving inhaled corticoids (IC). 69% had not diagnosed asthma. The B2 agonists are preferred out of all BD for EPOC and asthma. There was no difference between the centres (p < 0.07), nor between the BHA with or without teaching (p < 0.06). CONCLUSIONS: There is insufficient use of the PFR, including the PFM. SC with IC is rather infrequent. Asthma is the least diagnosed case, and is most confused with EPOC. A higher level of training is needed for GP doctors in the BHA's, and the setting of minimum criteria for action in the case of asthma and POCD.

Asthma↗

The importance of a pause between the inhalation of two puffs of terbutaline from a pressurized aerosol with a tube spacer.

In a double-blind crossover study, 16 children with asthma were treated with two puffs of terbutaline (0.25 mg per puff)/placebo from a pressurized aerosol with a tube spacer. The puffs of terbutaline were taken either immediately after each other (TT) or with a pause of 3 minutes (3TT) or 10 minutes (10TT) between the two puffs. All active treatments compared with placebo resulted in a significant bronchodilation, both under normal day-to-day conditions and during acute attacks of bronchoconstriction (p less than 0.01). Under basic conditions there was no statistically significant difference in increase in FEV1 after TT, 3TT, and 10TT treatments (22%, 24%, and 25%, respectively). During attacks of acute wheeze, however, a pause between the two puffs of terbutaline improved bronchodilation significantly from 49% (TT), to 68% (3TT), and 78% (10TT) (p less than 0.01). There was no statistically significant difference between 3TT and 10TT treatments. It is concluded that pauses between the doses of inhaled terbutaline is likely to improve bronchodilation during episodes of wheeze or poor control of symptoms, whereas there appears to be no need to recommend pauses between the puffs in the routine day-to-day management of children with moderate asthma.

Adolescent↗