The Australian Incident Monitoring Study. Problems with ventilation: an analysis of 2000 incident reports.

A review of the first 2000 incidents reported to the Australian Incident Monitoring Study found 317 incidents which involved problems with ventilation. The major portion (47%) were disconnections; 61% of these were detected by a monitor. Monitor detection was by a low circuit pressure alarm in 37% but this alarm failed to warn of non-ventilation in 12 incidents (in 6 because it was not switched "on" and in 6 because of a failure to detect the disconnection). Failure of detection was usually with ventilator bellows descending in expiration. Complete failure to ventilate occurred in 143 incidents, most commonly because of a disconnection. Disconnection was associated, in one-third of the cases, with interference to the anaesthetic circuit by a third party and in nearly half with surgery on the head and neck. Leaks affected ventilation in 129 incidents, but in only 19 was ventilation totally lost; leaks associated with seal failure of the absorber were common. Misconnections occurred in 36 incidents, most commonly involving the scavenging system. The frequency of a complete failure to check an anaesthetic machine was greater when an induction room was involved than when only the operating theatre was the site of the incident. These incidents suggest that meticulous checking and monitoring for failure of ventilation, preferably using at least two separate, self-activating systems is highly desirable. The Australian and New Zealand College of Anaesthetists' policy on low circuit pressure alarms, oximetry and capnography is vindicated by these reports.

Accidents↗

The Australian Incident Monitoring Study. Air embolism--an analysis of 2000 incident reports.

There were 19 cases of air embolism (1%) among the first 2000 incidents reported to the Australian Incident Monitoring Study. No embolism-induced fatalities were reported. Serious acute systemic effects occurred in 14 incidents; one circulatory arrest required electrical counter-shock. The surgical field was the entry route for the air in 63% of the incidents; 47% of the cases occurred during head and neck surgery. Capnography was the most successful first detector (26%) and it confirmed the diagnosis in another 26%. Invasive blood pressure monitoring, the electrocardiograph and the pulse oximeter played a useful role in detecting and/or confirming air embolism. Doppler monitoring was not reported in this series. A successful first response for management included head-down posture, manual ventilation, 100% oxygen and control of the air entry site. Cerebral arterial gas embolism may induce vascular endothelial damage and possible delayed neurological sequelae; hyperbaric oxygen therapy should be considered.

Anesthesia↗

The Australian Incident Monitoring Study. Paediatric incidents in anaesthesia: an analysis of 2000 incident reports.

The first 2000 incidents reported to the Australian Incident Monitoring Study (AIMS) were analysed to compare anaesthetic incidents in infants and children with those in adults. Of the 2000, 1790 (90%) involved adults, 151 (7%) children and 56 (3%) infants. Healthy children (ASA I) generated a greater proportion of incidents in this group than adults and infants, emphasizing the need for maintaining the same standards for children in this group as for infants and higher risk groups. The AIMS results are similar to those of the United States (US) paediatric "closed claims" studies; the paediatric subset in both the US study and AIMS made up 10% of the total. Also, in both studies, incidents involving the respiratory and breathing circuit systems accounted for nearly half the problems, and cardiovascular problems and problems with the anaesthetic machine each accounted for 10-14% of incidents. In the AIMS study procedures on the head and neck yielded proportionately more incidents in the infant/child group than in the adult group, as did incidents involving the respiratory and breathing circuit systems. Incidents in the child group were often detected clinically; however, there were no differences between the three age groups in the way monitors were used or performed; hence the same monitoring recommendations apply to all groups. Combined oximetry and capnography would have detected nearly 90% of all applicable problems in the AIMS study and could have prevented nearly 90% of the claims arising from inadequate ventilation in the US "closed claims" study.(ABSTRACT TRUNCATED AT 250 WORDS)

Accidents↗

Disconnect alarm failure in detection of common gas outlet disconnection.

This laboratory study was prompted by two paediatric cases where low pressure alarms and capnography failed to detect common gas outlet disconnection when using a T-piece pump ventilator. A carbon dioxide producing model lung was ventilated using the Clare ventilator (a T-piece pump type ventilator) via an Ayres T-piece. The T-piece used has 3 mm diameter fresh gas tubing. Common gas outlet disconnects were carried out using varying fresh gas flows and ventilatory patterns. At fresh gas flows of less than 8 l/min, the low pressure alarm of the Clare ventilator failed to sound following common gas outlet disconnection. Oxygraphy showed a rapid rise in inspired oxygen. End-tidal CO2 rose, whilst inspired CO2 remained at zero. This experiment demonstrates that the Clare ventilator's low pressure alarm detects common gas outlet disconnection poorly when used with an Ayres T-piece with narrow fresh gas tubing. Graphical representation of airway oxygen content has merit as an alerting monitor for common gas outlet disconnection.

Anesthesiology↗

Clinical evaluation of an instrument to measure carbon dioxide tension at the oxygenator gas outlet in cardiopulmonary bypass.

This paper presents the clinical testing of a new capnograph designed to measure the carbon dioxide tension at the oxygenator exhaust outlet in cardiopulmonary bypass (CPB). During CPB, there is a need for reliable, accurate and instant estimates of the arterial blood CO2 tension (PaCO2) in the patient. Currently, the standard practice for measuring PaCO2 involves the manual collection of intermittent blood samples, followed by a separate analysis performed by a blood gas analyser. Probes for inline blood gas measurement exist, but they are expensive and, thus, unsuitable for routine use. A well-known method is to measure PexCO2, ie, the partial pressure of CO2 in the exhaust gas output from the oxygenator and use this as an indirect estimate for PaCO2. Based on a commercially available CO2 sensor circuit board, a laminar flow capnograph was developed. A standard sample line with integrated water trap was connected to the oxygenator exhaust port. Fifty patients were divided into six different groups with respect to oxygenator type and temperature range. Both arterial and venous blood gas samples were drawn from the CPB circuit at various temperatures. Alfa-stat corrected pCO2 values were obtained by running a linear regression for each group based on the arterial temperature and then correcting the PexCO2 accordingly. The accuracy of the six groups was found to be (+/- SD): +/- 4.3, +/- 4.8, +/- 5.7, +/- 1.0, +/- 3.7 and +/- 2.1%. These results suggest that oxygenator exhaust capnography is a simple, inexpensive and reliable method of estimating the PaCO2 in both adult and pediatric patients at all relevant-temperatures.

Blood Gas Analysis↗

Ketamine-midazolam versus meperidine-midazolam for painful procedures in pediatric oncology patients.

PURPOSE: To compare the efficacy, characteristics of onset/recovery, and safety of ketamine/atropine/midazolam with meperidine/midazolam used as premedication for painful procedures in children with cancer. METHODS: A randomized, double-blind crossover trial for two successive painful procedures (bone marrow aspiration or biopsy, lumbar puncture, or combined procedures) was performed at a referral-based pediatric hematology-oncology clinic and associated inpatient service of a university teaching hospital. Twenty-two children, aged 24 to 178 months, were enrolled and 18 (81.8%) completed the double-blind, crossover trial. Each child received intravenous premedication with either meperidine 2 mg/kg and midazolam 0.1 mg/kg (MM) or atropine 0.01 mg/kg, midazolam 0.05 mg/kg, and ketamine 1.5 mg/kg (KM) on one occasion followed by the alternative regimen on a second occasion. The initial premedication regimen was chosen by random assignment. RESULTS: Efficacy was assessed by a trained observer using the Observational Scale of Behavioral Distress-Revised (OSBD-R). Operator, nurse, parent, and patient opinions of efficacy were recorded on a visual analog scale (VAS). Side effects were monitored by pulse oximetry, nasal end-tidal capnography, and serial blood pressure measurements. Use of KM resulted in significantly less procedural distress than MM (1.37 +/- 2.20 v 7.04 +/- 8.06 OSBD-R units; P < .05). Both operators and nurses rated KM more effective than MM. KM use was associated with earlier readiness for the procedure (19.2 v 24.0 minutes) and more rapid recovery (39.3 v 74.6 minutes for removal of monitoring devices and 58.5 v 87.1 minutes for discharge). Procedures undertaken after ketamine sedation were associated with fewer side effects than observed with MM sedation (hypoxia, 17.7% v 82.4%; hypotension, 16.6% v 55.6%; reduced respiratory rate, 0% v 38.9%). The incidence of emergence reactions or behavioral abnormalities within 24 hours postprocedure was similar in both treatment groups. At 7 days postprocedure, no child had persistent behavioral abnormalities and all children had amnesia for the procedure. Parents and children expressed a preference for KM over MM in 12 of 18 cases (P < .05). CONCLUSION: A premedication regimen of KM produced superior sedation with a faster onset and recovery and fewer side effects than a MM combination.

Anesthetics↗

High-frequency chest wall oscillation in ALS: an exploratory randomized, controlled trial.

OBJECTIVES: To evaluate changes in respiratory function in patients with ALS after using high-frequency chest wall oscillation (HFCWO). METHODS: This was a 12-week randomized, controlled trial of HFCWO in patients with probable or definite ALS, an Amyotrophic Lateral Sclerosis Functional Rating Scale respiratory subscale score < or = 11 and > or = 5, and forced vital capacity (FVC) > or = 40% predicted. RESULTS: We enrolled 46 patients (58.0 +/- 9.8 years; 21 men, 25 women); 22 used HFCWO and 24 were untreated. Thirty-five completed the trial: 19 used HFCWO and 16 untreated. HFCWO users had less breathlessness (p = 0.021) and coughed more at night (p = 0.048) at 12 weeks compared to baseline. At 12 weeks, HFCWO users reported a decline in breathlessness (p = 0.048); nonusers reported more noise when breathing (p = 0.027). There were no significant differences in FVC change, peak expiratory flow, capnography, oxygen saturation, fatigue, or transitional dyspnea index. When patients with FVC between 40 and 70% predicted were analyzed, FVC showed a significant mean decrease in untreated patients but not in HFCWO patients; HFCWO patients had significantly less increased fatigue and breathlessness. Satisfaction with HFCWO was 79%. CONCLUSION: High-frequency chest wall oscillation was well tolerated, considered helpful by a majority of patients, and decreased symptoms of breathlessness. In patients with impaired breathing, high-frequency chest wall oscillation decreased fatigue and showed a trend toward slowing the decline of forced vital capacity.

Aged↗

Respiratory frequency and artifact affect the capnographic baseline in infants.

We sought to determine the effect of rebreathing on the capnographic waveform baseline. In anesthetized infants, we studied the effect of respiratory frequency (f) and breathing circuit type (Bain, n = 6, and pediatric circle, n = 4) on capnography of respiratory gas aspirated from the circuit for mass spectrometry (PCO2asp) and flowing through an infrared analyzer (PCO2f-t). As f increased, measured values of PiCO2asp and PiCO2f-t increased in both Bain and circle groups, with the exception of PiCO2f-t values that remained zero in the circle group. PETCO2 decreased as f increased in the circle groups, but remained constant in the Bain groups. These data suggest that artifact, most likely due to parabolic distortion of CO2 plugs traversing long sampling catheters, makes up a significant percentage (8%-36%) of the aspiration capnographic baseline elevation depending on f and breathing circuit type. Despite increases in PiCO2 as f increased, PETCO2 does not increase in Bain circuits due primarily to an increase in minute ventilation (Ve) that offsets the increase in the PiCO2 to provide balance in the CO2 mass relationship (PETCO2 approximately VCO2/Ve+PiCO2). These findings are useful in the correct interpretation of elevated capnographic baseline in infants.

Anesthesia, Closed-Circuit↗

Magnetic orotracheal intubation: a new technique.

We sought to determine the effectiveness of a magnet placed over the thyroid cartilage in the neck to guide an endotracheal tube into the trachea. Forty patients aged 18 to 60 yr with normal airway anatomy (ASA grade I) who required general anesthesia with an endotracheal tube and paralysis for their surgery were chosen and informed consents were obtained. The tip of the epiglottis was exposed with a No. 3 MacIntosh laryngoscope, and a magnet was held over the thyroid cartilage. A catheter with stylet was placed behind the epiglottis allowing the magnet to pull the stylet and catheter close to the glottic opening. The catheter was advanced into the trachea over the stylet and its position was confirmed by auscultating the lungs and by capnography. An extension tube was connected to the catheter, and the endotracheal tube was guided into the trachea over the catheter. The tracheas of 37 patients were intubated on the first attempt with the magnet. The tracheas of the remaining three patients could not be intubated on the first attempt but were successfully intubated without complications on the second attempt. An additional five patients with an anterior larynx whose tracheas could not be intubated with direct laryngoscopy also had tracheal intubation with a magnet. This magnet-guided technique can be used when it is difficult to expose a patient's larynx. It is noninvasive, simple, and can be used without any delay when expensive flexible fiberoptic endoscopes are not readily available. The procedure takes an average of 1 to 2 min.

Adult↗

A novel molecule (frakefamide) with peripheral opioid properties: the effects on resting ventilation compared with morphine and placebo.

In animal models frakefamide (FF) is a potent analgesic that acts as a peripheral active mu-selective receptor agonist. In this double-blind, randomized, double dummy four-way crossover study in 12 healthy male subjects, we investigated the effects on resting ventilation of FF and 2 dose levels of morphine compared with placebo. Each drug was infused for 6 h. The subjects received 1.22 mg/kg FF, 0.43 mg/kg morphine (M-large), and 0.11 mg/kg morphine (M-small). Sodium chloride 9 mg/mL was used as placebo. Ventilation was measured by pneumotachography and inline capnography. Blood was collected and plasma concentrations of FF and morphine and its metabolites were analyzed. Within 15 min after administration of FF all subjects complained of a transient myalgia, which disappeared within 30 min. At target measurement (335 min), there were no differences in tidal volume among the groups. Respiratory rates were, however, slower in the two M-groups (P < 0.05 in M-small and P < 0.001 in M-large) compared with FF and placebo. Minute volume was significantly less in the M-large group compared with the FF (P < 0.01) and placebo (P < 0.01) groups. This difference was reflected by an elevated ETco(2) in the M-large group (P < 0.01). We conclude that, during resting ventilation, FF, unlike morphine, did not cause central respiratory depression. This suggests that FF has only peripheral mu-opioid agonist activity in humans.

Adolescent↗

Optimization of endotracheal tube cuff filling by continuous upper airway carbon dioxide monitoring.

UNLABELLED: Inappropriate cuff filling is responsible for various complications related to the use of an endotracheal tube (ETT). In this study, we evaluated an objective, noninvasive method for continuous assessment of leak around the ETT cuff by monitoring carbon dioxide pressure (P(CO2) in the upper airway. P(CO2) levels were measured by capnography simultaneously between the ETT cuff and the vocal cords, at the oropharynx, and in the nares of the nose. Cuff filling was regulated by an electronic controller to achieve the minimal pressure needed to prevent CO2 leak. Feasibility of the method was assessed in a human simulator and in a porcine model. Clinical function was evaluated in 60 patients undergoing surgery, comparing the method to the standard anesthesiologist evaluation. Linear correlations were observed between the ETT cuff pressure and P(CO2) level in the human simulator (R2 = 0.954, P < 0.0001) and in the porcine model (R2 > 0.98, P < 0.0001). Iodine leak around the ETT cuff, in the porcine model, occurred only when P(CO2) levels were >2 mm Hg. In the surgery patients, the mean ETT cuff pressure determined clinically by the anesthesiologist was significantly higher than the optimal cuff pressure assessed by P(CO2) (25.2 +/- 3.6 versus 18.2 +/- 7.8 mm Hg, respectively; P < 0.001). According to these findings, optimal ETT cuff filling pressure can be identified by monitoring P(CO2) at the nares or the oropharynx. IMPLICATIONS: A new, objective, noninvasive method for optimizing endotracheal tube cuff filling based on monitoring carbon dioxide levels in the upper airways can be used to identify the minimal cuff pressure necessary to eliminate leak and prevent aspiration.

Animals↗

A novel molecule with peripheral opioid properties: the effects on hypercarbic and hypoxic ventilation at steady-state compared with morphine and placebo.

Frakefamide (FF), is a new peripherally acting mu-opioid receptor agonist. The aim of this double-blind, randomized, double-dummy, four-way, crossover study was to investigate FF effects on hypercarbic and hypoxic ventilation at steady-state after a 6-h infusion. We compared the effect with 2 clinical doses of morphine (M-small and M-large) and placebo in 12 healthy men. The subjects received 1.22 mg/kg of FF, 0.44 mg/kg of M-large, and 0.11 mg/kg of M-small. Sodium chloride 9 mg/mL was used as placebo. Ventilation was studied by pneumotachography and in-line capnography. There were no ventilatory effects caused by FF or placebo. As expected, large doses of morphine influenced both hypercarbic and hypoxic ventilatory responses. We conclude that there were no signs of central respiratory depression caused by FF after 6 h of constant infusion, which supports a peripheral action of the compound. However, morphine caused a dose-dependent central depression during the hypercarbic ventilatory response and a mild depression of hypoxic ventilatory response.

Adolescent↗

Remote anesthetic monitoring using satellite telecommunications and the Internet.

Remote collaboration for anesthesia requires considerable sharing of physiologic data, audio, and images on a consistent data platform. A low-bandwidth connection between Ecuador and the United States supported effective joint management of operative plan, airway, intraoperative decisions, and recovery. Transmission with a 64-Kbps InMarSat satellite telephone (Thrane & Thrane, Denmark) connection from hospitals in Macas and Sucúa, Ecuador, to Richmond, Virginia, included preoperative patient evaluations, video of endotracheal intubations, electrocardiogram waveforms, pulse oximetry measurements, arterial blood pressure readings, capnography readings, and auscultation of breath sounds.

Anesthesia↗

Periodic breathing imitating hyperventilation syndrome.

We report a male patient who developed an unusual periodic breathing. At presentation, the differential diagnosis at bedside between Cheyne-Stokes and primary hyperventilation syndrome was laborious, and the final verification was based on the result of capnography.

Cheyne-Stokes Respiration↗

Sleep and nocturnal mouthpiece IPPV efficiency in postpoliomyelitis ventilator users.

STUDY OBJECTIVE: Intermittent positive pressure ventilation (IPPV) can be delivered via various oral, nasal, or oronasal interfaces as an alternative to tracheostomy for up to 24 h of ventilatory support. Nocturnal nasal IPPV is often associated with frequent transient but at times severe oxyhemoglobin desaturations (dSaO2s) and sleep fragmentation. The purpose of this study was to determine if nocturnal mouthpiece IPPV is also associated with dSaO2s and sleep disruption. DESIGN: Twenty-seven postpolio ventilator-assisted individuals (VAIs) using mouthpiece IPPV with little or no ventilator-free breathing time (VFBT) underwent nocturnal oxyhemoglobin saturation (SaO2) monitoring. In addition, 15 underwent nocturnal capnography and 13 underwent polysomnography. RESULTS: Mean nocturnal SaO2 was normal in 22 of 27 and maximum end-tidal PCO2 was normal in 12 of 15 VAIs. Use of lipseal retention for nocturnal mouthpiece IPPV significantly improved blood gas values during sleep. The polysomnography results demonstrated relatively normal sleep efficiency. CONCLUSIONS: Nocturnal mouthpiece IPPV is most effective with lipseal retention. It can provide normal alveolar ventilation and SaO2 during sleep for VAIs with little or no measurable vital capacity or VFBT. Because transient dSaO2s can be eliminated with lipseal retention, it may disrupt sleep less than nasal IPPV.

Carbon Dioxide↗

What intraoperative monitoring makes sense?

The routine practice of monitoring oxygenation, ventilation, circulation, and temperature during surgery is now the standard of care. However, with the possible exception of pulse oximetry and capnography, extensive physiologic monitoring has not been shown to reduce the incidence of adverse anesthetic-related events. Monitors are useful adjuncts, but they alone cannot replace careful observation by a vigilant anesthesiologist.

Anesthesia↗

Trials of miscellaneous interventions to wean from mechanical ventilation.

We found eight randomized controlled trials (RCTs) of miscellaneous interventions that were designed to facilitate the process of weaning from mechanical ventilation. The two RCTs of high-fat/low-carbohydrate enteral nutrition found favorable physiologic effects on CO2 production and respiratory quotient, rendering this type of nutrition potentially useful in patients with impaired ventilatory reserve; however, no conclusions can be made about the outcomes of the duration of ventilation and weaning success. The two RCTs of postextubation use of noninvasive ventilation are conflicting, showing potential short-term physiologic benefit in one study, but no benefit in terms of reintubation rates or other morbidity. These RCTs are less promising than other applications of noninvasive ventilation such as those in patients with COPD exacerbations. One RCT showed no improvement in success of weaning with exogenous growth hormone administration. In the setting of very frequent baseline blood gas analyses, one RCT of oximetry and capnography was associated with significantly fewer blood gas analyses. Biofeedback to enhance safe and rapid weaning showed a dramatically lower duration of ventilation in one RCT that did not report the weaning methods used. One RCT of preextubation acupuncture showed lower rates of laryngospasm in the acupuncture group. Overall, these studies were underpowered for clinically important outcomes. Multidisciplinary, patient-centered, holistic, and non-pulmonary approaches to weaning may provide additional safe, effective adjunctive methods of hastening liberation from mechanical ventilation.

Acupuncture↗

Supplemental oxygen impairs detection of hypoventilation by pulse oximetry.

STUDY OBJECTIVE: This two-part study was designed to determine the effect of supplemental oxygen on the detection of hypoventilation, evidenced by a decline in oxygen saturation (Spo(2)) with pulse oximetry. DESIGN: Phase 1 was a prospective, patient-controlled, clinical trial. Phase 2 was a prospective, randomized, clinical trial. SETTING: Phase 1 took place in the operating room. Phase 2 took place in the postanesthesia care unit (PACU). PATIENTS: In phase 1, 45 patients underwent abdominal, gynecologic, urologic, and lower-extremity vascular operations. In phase 2, 288 patients were recovering from anesthesia. INTERVENTIONS: In phase 1, modeling of deliberate hypoventilation entailed decreasing by 50% the minute ventilation of patients receiving general anesthesia. Patients breathing a fraction of inspired oxygen (Fio(2)) of 0.21 (n = 25) underwent hypoventilation for up to 5 min. Patients with an Fio(2) of 0.25 (n = 10) or 0.30 (n = 10) underwent hypoventilation for 10 min. In phase 2, spontaneously breathing patients were randomized to breathe room air (n = 155) or to receive supplemental oxygen (n = 133) on arrival in the PACU. MEASUREMENTS AND RESULTS: In phase 1, end-tidal carbon dioxide and Spo(2) were measured during deliberate hypoventilation. A decrease in Spo(2) occurred only in patients who breathed room air. No decline occurred in patients with Fio(2) levels of 0.25 and 0.30. In phase 2, Spo(2) was recorded every min for up to 40 min in the PACU. Arterial desaturation (Spo(2) < 90%) was fourfold higher in patients who breathed room air than in patients who breathed supplemental oxygen (9.0% vs 2.3%, p = 0.02). CONCLUSION: Hypoventilation can be detected reliably by pulse oximetry only when patients breathe room air. In patients with spontaneous ventilation, supplemental oxygen often masked the ability to detect abnormalities in respiratory function in the PACU. Without the need for capnography and arterial blood gas analysis, pulse oximetry is a useful tool to assess ventilatory abnormalities, but only in the absence of supplemental inspired oxygen.

Aged↗