Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Biodegradable Delivery Systems”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Development of a calcium phosphate co-precipitate/poly(lactide-co-glycolide) DNA delivery system: release kinetics and cellular transfection studies.

One of the most common non-viral methods for the introduction of foreign deoxyribonucleic acid (DNA) into cultured cells is calcium phosphate co-precipitate transfection. This technique involves the encapsulation of DNA within a calcium phosphate co-precipitate, particulate addition to in vitro cell culture, endocytosis of the co-precipitate, and exogenous DNA expression by the transfected cell. In this study, we fabricated a novel non-viral gene transfer system by adsorbing DNA, encapsulated in calcium phosphate (DNA/Ca-P) co-precipitates, to biodegradable two- and three-dimensional poly(lactide-co-glycolide) matrices (2D-DNA/Ca-P/PLAGA, 3D-DNA/Ca-P/PLAGA). Co-precipitate release studies demonstrated an initial burst release over the first 48 h. By day 7, approximately 96% of the initially adsorbed DNA/Ca-P co-precipitate had been released. This was followed by low levels of co-precipitate release for 42 days. Polymerase chain reaction was used to demonstrate the ability of the released DNA containing co-precipitates to transfect SaOS-2 cells cultured in vitro on the 3D-DNA/Ca-P/PLAGA matrix and maintenance of the structural integrity of the exogenous DNA. In summary, a promising system for the incorporation and controlled delivery of exogenous genes encapsulated within a calcium phosphate co-precipitate from biodegradable polymeric matrices has been developed and may have applicability to the delivery of therapeutic genes and the transfection of other cell types.

Adsorption↗

Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent.

AIM: The aim of this study was to assess technical feasibility, biocompatibility, and impact on coronary stenosis of a new biodegradable paclitaxel-loaded polylactide stent. Due to high rates of in-stent restenosis and permanent nature of metal stent implants, synthetic polymers have been proposed as surrogate materials for stents and local delivery systems for drugs. Paclitaxel was shown to inhibit vascular smooth muscle cell proliferation and migration. METHODS AND RESULTS: A novel biodegradable double-helical stent was manufactured using controlled expansion of saturated polymers (CESP) for the moulding of a bioresorbable poly(D,L)-lactic acid (PDLLA). A modified balloon catheter for stent deployment was developed according to the mechanical stent properties. Twelve paclitaxel-loaded (170 microg) polylactide stents, 12 unloaded polylactide stents, and 12 316L bare metal stents were deployed in porcine coronary arteries of 36 animals. Six pigs of each group were sacrificed after 3 weeks and 3 months, respectively, for every setting. Drug release kinetics as well as histomorphometrical and histopathological analyses were performed. A slow paclitaxel release kinetic for more than 2 months and therapeutic tissue concentrations were demonstrated. Coronary stenosis after implantation of paclitaxel-loaded stents (30+/-5% or 49+/-4%) was significantly inhibited compared to unloaded PDLLA stents (65+/-10%, P=0.021 or 71+/-4%, P=0.004) and metal stents (53+/-6% or 68+/-8%, P=0.029 and P=0.020) after 3 weeks or 3 months. Early complete endothelialisation was shown. Nevertheless, a local inflammatory response to the polylactide as a result of the polymer resorption process was observed. CONCLUSIONS: This novel polylactide stent showed sufficient mechanic stability, and by incorporation of paclitaxel, a significant potential to reduce restenosis development after vascular intervention was seen.

Animals↗

Poly(ethylene oxide)-modified poly(beta-amino ester) nanoparticles as a pH-sensitive system for tumor-targeted delivery of hydrophobic drugs. 1. In vitro evaluations.

A representative poly(beta-amino ester) (PbAE) with biodegradable and pH-sensitive properties was used to formulate a nanoparticle-based dosage form for tumor-targeted paclitaxel delivery. The polymer undergoes rapid dissolution when the pH of the medium is less than 6.5 and hence is expected to release its contents at once within the acidic tumor microenvironment and endo/lysosome compartments of cells. PbAE nanoparticles were prepared by solvent displacement method and characterized for particle size, charge, and surface morphology. Pluronic F-108, a triblock copolymer of poly(ethylene oxide) (PEO) and poly(propylene oxide) (PPO), was blended with PbAE to induce surface modification of the nanoparticles. In vitro cellular uptake of tritiated [(3)H]-paclitaxel in solution form and as a nanoparticulate formulation was studied in MDA-MB-231 human breast adenocarcinoma cells grown in 12-well plates. We also examined the intracellular degradation pattern of the formulations within the cells by estimating the drug release profile. Cytotoxicity assay was performed on the formulations at different doses and time intervals. Nanoparticles prepared from poly(epsilon-caprolactone) (PCL) that do not display pH-sensitive release behavior were used as control. Spherical nanoparticles having positive zeta potential ( approximately 40 mV) were obtained in the size range of 150-200 nm with PbAE. The PEO chains of the Pluronic were well-anchored within the nanomatrix as determined by electron spectroscopy for chemical analysis (ESCA). The intracellular accumulation of paclitaxel within tumor cells was significantly higher when administered in the nanoparticle formulations as compared to aqueous solution. Qualitative fluorescent microscopy confirmed the rapid release of the payload into the cytosol in the case of PbAE nanoparticles, while the integrity of the PCL nanoparticles remained intact. The cytotoxicity assay results showed significantly higher tumoricidal activity of paclitaxel when administered in the nanoparticle formulations. The cell-kill effect was maximal for paclitaxel-loaded PbAE nanoparticles when normalized with respect to intracellular drug concentrations. Thus, PEO-modified PbAE nanoparticles show tremendous potential as novel carriers of cytotoxic agents for achieving improved drug disposition and enhanced efficacy.

Cell Line, Tumor↗

Materials and biological aspects of synthetic polymers in controlled drug release systems: problems and challenges.

The physico-chemical and biological aspects of polymeric materials represent vital areas in the reliable, safe, and efficacious functioning of controlled drug-delivery devices. In the case of implantable systems, potential biological problems include incompatibility of the polymers and their degradation products with the physiological environment, adverse metabolic consequences of the degradation products, and occlusion of the drug conduits (catheters) with thrombi and/or drugs, (i.e., insulin aggregates). In the case of transcutaneous drug delivery systems, proper consideration must be given to avoid skin irritation and allergic responses as well as other toxic effects. With biodegradable systems that may follow simple hydrolysis and/or enzyme-catalyzed degradation of labile chemical side-chains that hold the drug molecule and/or the main polymer chain, increased attention must be given not only to the short-term but also the long-term metabolic consequences of the degradation products. Although the term "biodegradation" is often used for in vitro situations it should be reserved only for in vivo circumstances as, at the present time, no in vitro experiments can completely simulate the in vivo environment. The misuse of this term may lead to premature predictions as to the performance of a device in vivo, a situation that ought to be avoided. Appropriate attention must also be given to the effect of drugs on polymers as drug/polymer interactions may influence the stability of both the polymers and drugs and may result in altered therapeutic performance. Standards are needed to clearly differentiate between controlled drug delivery systems and older "sustained" and "time-release" preparations.

Biodegradation, Environmental↗

In vitro elution of antibiotic from antibiotic-impregnated biodegradable calcium alginate wound dressing.

OBJECTIVE: The authors investigated the calcium alginate dressing as a drug-delivery system for the treatment of various surgical infections. METHODS: Cytotoxicity of the calcium alginate dressing to fibroblasts and HeLa cells was evaluated by the 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H tetrazolium bromide (MITT) colorimetric assay. The calcium alginate dressing was mixed with vancomycin, and lyophilized or not lyophilized to form two types of antibiotic dressings. The antibiotic dressings were placed in 2 mL of phosphate buffered saline (PBS) or in PBS containing 0.01% calcium ions, and incubated at 37 degrees C. The PBS was changed daily, and the removed solutions were stored at -70 degrees C until the antibiotic concentration in each sample was determined by high performance liquid chromatography assay. RESULTS: The results suggested that the antibiotic dressings present no obvious toxic risk to their use as a drug-delivery system. The concentration of vancomycin in each sample was well above the breakpoint sensitivity concentration (the antibiotic concentration at the transition point between bacterial kill. ing and resistance to the antibiotic) for more than 14 days. The release was most marked during the first 48 hours. The concentration of calcium ions in PBS and the lyophilization of the manufacture process of antibiotic dressings prolonged the antibiotic diffusion duration. The diameter of the sample inhibition zone ranged from 10 to 11 mm, and the relative activity of vancomycin ranged from 62.88% to 92.18%. CONCLUSION: All antibiotic dressings released bactericidal concentrations of the antibiotics in vitro for the period of time needed to treat surgical infections. This study offers a convenient method to meet the specific antibiotic requirement for different patients.

Alginates↗

Influence of manufacturing parameters on development of contraceptive steroid loaded injectable microspheres.

The main objective of this work was to develop a system consisting of polymeric microspheres loaded with steroid drugs. The drugs were encapsulated using biodegradable poly(lactide-co-glycolide) (PLG) and poly(epsilon-caprolactone) (PCL) by double emulsion solvent evaporation method. The lipophilic drugs, levonorgestrel and ethinylestradiol were made soluble by adding ethanol/water mixture. The effects of parameters like polymer concentration and stabilizer concentration were studied on the size, size distribution, surface properties and loading efficiencies of microspheres. The formulated microspheres were smooth, spherical and uniform in shape and size. Fourier transformed infrared spectroscopy and differential scanning calorimetry studies seemed to confirm the absence of chemical interaction between the drugs and the polymers, while the drugs were dispersed in the polymer. The increase in polymer concentrations increased the size as well as the loading efficiency of microspheres. Data obtained in this study demonstrated that the PLG/PCL microspheres may be a suitable polymeric carrier for long acting injectable drug delivery.

Biodegradation, Environmental↗

Controlled release of gentamicin from calcium phosphate-poly(lactic acid-co-glycolic acid) composite bone cement.

Modification of a self setting bone cement with biodegradable microspheres to achieve controlled local release of antibiotics without compromising mechanical properties was investigated. Different biodegradable microsphere batches were prepared from poly(lactic-co-glycolic acid) (PLGA) using a spray-drying technique to encapsulate gentamicin crobefate varying PLGA composition and drug loading. Microsphere properties such as surface morphology, particle size and antibiotic drug release profiles were characterized. Microspheres were mixed with an apatitic calcium phosphate bone cement to generate an antibiotic drug delivery system for treatment of bone defects. All batches of cement/microsphere composites showed an unchanged compressive strength of 60 MPa and no increase in setting time. Antibiotic release increased with increasing drug loading of the microspheres up to 30% (w/w). Drug burst of gentamicin crobefate in the microspheres was abolished in cement/microsphere composites yielding nearly zero order release profiles. Modification of calcium phosphate cements using biodegradable microspheres proved to be an efficient drug delivery system allowing a broad range of 10-30% drug loading with uncompromised mechanical properties.

Animals↗

Control of blood glucose by novel GLP-1 delivery using biodegradable triblock copolymer of PLGA-PEG-PLGA in type 2 diabetic rats.

PURPOSE: The incretin hormone glucagon-like peptide-1 (GLP-1) is a promising candidate for treatment of type 2 diabetes mellitus. However, plasma half-life of GLP-1 is extremely short, thus multiple injections or continuous infusion is required for therapeutic use of GLP-1. Therefore, we investigated a new delivery system as a feasible approach to achieve sustained GLP-1 release for a 2-week period. METHODS: A water-soluble, biodegradable triblock copolymer of poly [(DL-lactide-co-glycolide)-b-ethylene glycol-b-(DL-lactide-coglycolide)] (ReGel) was used in this study as an injectable formulation for controlled release of GLP-1. GLP-1 was formulated into ReGel as insoluble zinc complex to stabilize GLP-1 against aggregation and slow down release. The GLP-1 release profile was monitored in vitro and in vivo. Zucker Diabetic Fatty rats were administered subcutaneously with the GLP-1 formulation. The concentration of GLP-1, insulin, and glucose was monitored every day after the GLP-1 administration. RESULTS: The GLP-1 release from ReGel formulation in vitro and in vivo showed no initial burst and constant release for 2 weeks. Animal study demonstrated that the plasma insulin level was increased, and the blood glucose level was controlled for 2 weeks by one injection of ReGel/ ZnGLP-1 formulation. CONCLUSIONS: It is concluded that one injection of zinc-complexed GLP-1 loaded ReGel can be used for delivery of bioactive GLP-1 during a 2-week period. Because this new delivery system is biocompatible and requires twice-a-month injection, it can improve patient compliance and cost-effectiveness.

Animals↗

Structural properties of biodegradable polyesters and rheological behaviour of their dispersions and films.

This paper focuses on the dependence of the rheological properties of PLA-PEG and PLGA dispersions and films on the polymer structural properties, in order to obtain useful information to predict and explain the performance of polyester films as drug-delivery systems. In this study, one PLA-PEG and three PLGA polymers of different molecular mass were synthesized and characterized by NMR, GPC, DSC and TGA-FT-IR. To characterize the viscoelastic behaviour of concentrated solutions in dichloromethane and of the films obtained by a solvent-casting technique, oscillatory shear rheometry was used. The polymer dispersions showed a characteristic Newtonian viscous behaviour, but with different consistency index depending on the nature of the polymer. Freshly prepared, PLGA and PLA-PEG films had elastic modulus (G') greater than viscous modulus (G"). The decrease in both moduli caused by an increase in temperature from 25 to 37 degrees C was especially marked for the polymers with T(g) below or around 25 degrees C (PLGA 27 kDa and PLA-PEG 27 kDa). After being immersed in pH 7.4 aqueous solution for one week, PLGA films showed a significant increase in both G' and G", due to the promotion of polymer-polymer interactions in a non-solvent medium. In contrast, the PLA-PEG film became softer and more hydrated, due to the amphiphilic character of the polymer. The water taken up by the film acted as a plasticizer and induced the softening of the system. These results suggest that the presence of PEG chains exerts a strong influence on the mechanical properties of polyesters films and, possibly, the performance as coating or matrices of drug-delivery systems.

Biodegradation, Environmental↗

Biodegradable dextran-based microspheres for delivery of anticancer drug mitomycin C.

The purpose of this work was to develop a biodegradable microsphere (MS) system for delivering mitomycin C (MMC). Various dextran-based MS systems were investigated for their loading and release characteristics, including nonionic MS, sulfopropyl dextran microspheres (SP-MS) with low or high cross-linking density, oxidized SP-MS (Ox-MS), and hydrophobically modified SP-MS. SP-MS were chemically modified by oxidation with sodium periodate or by reaction with anhydride. The chemical structure of modified SP-MS and MMC-loaded MS (MMC-MS) were examined using Fourier transform infrared (FTIR) and solid-state nuclear magnetic resonance (NMR) spectrophotometry. Drug release was conducted at 37 degrees C in aqueous solutions of 0.15 m phosphate buffer solution. The kinetics of drug absorption and release and the stability of MMC after loading and release were determined by spectrophotometry and high-performance liquid chromatography. Ionic SP-MS exhibited a higher drug-loading rate and capacity when compared to nonionic MS, while hydrophobically modified SP-MS showed an even greater loading capacity than SP-MS. These results suggest that both ionic complexation and hydrophobic interaction were important factors in MMC loading. The Ox-MS system demonstrated higher drug-loading capacity, more fractional drug release and a longer time to reach release equilibrium as compared to other investigated MS systems. Under optimized reaction and loading conditions, MMC released from Ox-MS was found to be unaltered. This work demonstrates that the Ox-MS system is a potentially useful system for the delivery of MMC.

Absorbable Implants↗

Induction of anti-idiotypic humoral and cellular immune responses by a murine monoclonal antibody recognizing the ovarian carcinoma antigen CA125 encapsulated in biodegradable microspheres.

The use of biodegradable poly(DL-lactic-co-glycolic acid) microspheres as a cancer vaccine delivery system for induction of anti-idiotypic responses was investigated using a murine monoclonal antibody B43.13 that recognizes the human ovarian cancer antigen CA125. Immunization of mice with mAb B43.13 encapsulated in poly(DL-lactic-co-glycolic acid) microspheres resulted in enhanced humoral and cellular immune responses compared with mAb B43.13 alone or mAb B43.13 mixed with microspheres. The antibody responses could be further enhanced by the co-encapsulation of mAb B43.13 with monophosphoryl lipid A, a non-toxic adjuvant, in microspheres. Anti-idiotypic humoral responses were shown to result in Ab2 antibodies mimicking the nominal antigen CA125 and Ab3 antibodies recognizing CA125. Further, microsphere delivery of mAb B43.13 also resulted in induction of T cell responses involving T2 cells reactive with mAb B43.13 epitopes and T3 cells recognizing CA125. These results indicate that microsphere delivery of Abl can induce both humoral and cellular anti-idiotypic responses relevant to cancer antigens. This raises the possibility of the use of such formulations for anti-idiotypic induction immunotherapy for cancer.

Animals↗

Subgingival controlled release of antimicrobial agents in the treatment of periodontal disease.

Local drug delivery of antimicrobics by sustained release delivery systems can be used to treat periodontal disease. Advantages of these systems may include biodegradation of the system, maintaining high levels of antibiotic in the gingival crevicular fluid (GCF) for a sustained period of time and ease of use with high patient acceptance. This review will identify human in vivo clinical and microbiological studies. Sustained release formulations, application methods, clinical results and microbiological effects are discussed.

Anti-Infective Agents↗

Use of encapsulated single chain antibodies for induction of anti-idiotypic humoral and cellular immune responses.

The use of biodegradable poly(lactic-co-glycolic acid) (PLGA) microspheres as a cancer vaccine delivery system for induction of anti-idiotypic responses has been investigated using a single chain antibody scFv-pDL10, which recognizes the human ovarian cancer antigen CA125. Immunization of mice with scFv-pDL10 encapsulated in PLGA microspheres resulted in enhanced humoral and cellular immune responses when compared to scFv-pDL10 alone. Induced anti-idiotypic antibodies (Ab2) which mimic the original antigen CA125 compete with CA125 for the epitope. A cellular response (T2 induction) was also observed. These results raise the possibility of anti-idiotypic antibody induction by a single chain antibody, encapsulated in biodegradeble microspheres, as a potential vaccine for ovarian carcinoma.

Animals↗

Localized adenovirus gene delivery using antiviral IgG complexation.

Gene therapy with viral vectors has progressed to clinical trials. However, the localization of viral vector delivery to diseased target sites remains a challenge. We tested the hypothesis that an adenoviral vector could be successfully delivered by complexation with a specific antibody that is bound to a biodegradable matrix designed for achieving localized gene transduction. We report the first successful delivery system based upon antibody immobilization of virions in a type I collagen-avidin gel using a polyclonal biotinylated IgG specific for the adenovirus hexon. In vitro stability studies demonstrated retention of viral vector activity with antibody-complexed adenovirus collagen gel preparations, in comparison to loss of vector activity from collagen gels prepared with nonspecific biotinylated IgG. Cell culture investigations using this antibody-controlled release system for adenoviral vector transduction of rat aortic smooth muscle cells (A10) demonstrated a significantly more localized reporter expression (beta-galactosidase) compared with non-antibody-complexed controls. Herpes simplex thymidine kinase (HSVtk) adenoviral vectors were immobilized on avidin-collagen gels via this antibody-complexation approach, and ganciclovir was added to rat smooth muscle cells (A10) in culture with the gels. With complexed HSVtk adenovirus, only cells either in contact with the virus-containing gel or within 50 microm were killed. By comparison, at the same adenovirus and ganciclovir dose, non-antibody-complexed HSVtk adenoviral delivery with ganciclovir resulted in the death of virtually all cells. Myocardial gene transfer studies in pigs demonstrated significantly more efficient right ventricular adenoviral GFP expression with anti-hexon antibody-complexed matrix injections, compared with direct vector injections. Thus, our results show that matrix formulations based on antibody-complexation delivery of adenovirus resulted in site-specific localization of transgene expression that enhances the efficiency of therapeutic vector strategies and provides a potent means for localization, to avoid distal side-effects. This approach has therapeutic potential as an implantable preparation that through the means of antibody-complexation, can localize and optimize viral vector gene therapy.

Adenoviridae↗

Tissue engineering in the twenty-first century.

In the 20th century, free tissue transfers have been successfully introduced using microvascular anastomosis techniques. Transplants not only include whole organs such as the kidney, liver and lung, but also bone, muscle and skin. However, there are a limited number of organs available for transplantation. This leads to the patient not only suffering from the malfunctioning tissue or organ, but also from the psychological trauma of an indefinite waiting period. The rapidly evolving field of tissue engineering is beginning to have an impact on free tissue transfers including organ. Small biopsy specimens can be grown into a large number of cells. These cultured cells can then be seeded onto biodegradable polymers, which serve several purposes. Firstly, the polymers function as a cell delivery system that enables the transplantation of a large numbers of cells into an organism. Secondly, they create a three-dimensional space for cell growth and serve as a template, thereby providing a structure for the extracellular matrix. These approaches have been demonstrated as practical strategies for the reconstruction of many tissues such as the liver, intestines, heart valve leaflets, bone and cartilage.

Animals↗

[Some interactions of natural and synthetic anionic polymers with biologically active substances].

Anionic polymers are nowadays extensively used in drug form technology, especially in drug delivery and drug targeting. Development of proper drug and macromolecular excipient composition allows controlled drug delivery in the term of the drug concentration in blood or other tissues, and in the term of the action-time. Between anionic polymers most frequently carbopols, eudragits, alginates and pectins are used. Application of anionic polymers in drug form technology is an up to date problem. According to new synthesis methods and new anionic polymers, new drug delivery systems would be researched. Most selective and safe devices should be developed, concerning biodegradation aspects.

Acrylic Resins↗

Polyalkylcyanoacrylates as colloidal drug carriers.

A considerable amount of energy has been spent in creating new colloidal drug delivery systems that are acceptable for general systemic use. Among these new systems, nanoparticles made with biodegradable polymers are gaining more and more interest. The aim of this paper is to describe the preparation and characterization of these nanoparticles and their in vivo behavior and to show the possibilities of using them in various fields of human medicine. The interaction of polyalkylcyanoacrylate nanoparticles with cells in culture is also discussed, as well as the possibility of improving the specificity of the carrier by coating it with monoclonal antibodies.

Antibodies, Monoclonal↗

Pharmacokinetic and toxicity investigations of a new intraocular lens with a dexamethasone drug delivery system: a pilot study.

AIM: To investigate the short-term safety and pharmacokinetic behavior of a new intraocular lens containing a dexamethasone drug delivery system (IOL-DDS) in rabbit eyes. METHODS: A modified polymethylmethacrylate IOL containing a biodegradable dexamethasone DDS was implanted into the posterior chamber of the right eyes of 9 New Zealand white rabbits. Serial slitlamp and indirect ophthalmoscopic examinations (including grading of intraocular inflammation) were performed. After 3, 6 and 9 days, the rabbits were euthanized and the globes were removed for histological examination and for determination of dexamethasone levels in the aqueous humor and in the vitreous. Analysis of dexamethasone concentrations was performed by ELISA. RESULTS: Therapeutic concentrations of dexamethasone were detectable in the aqueous and vitreous of the study eyes throughout the 9-day period in all tested animals. The mean aqueous dexamethasone concentration (ng/ml, +/- SD) was 1,015.42 (+/- 43.05), 970.11 (+/- 32.47) and 757.58 (+/- 30.19) and the mean vitreous concentration (ng/ml, +/- SD) was 399.82 (+/- 38.05), 287.38 (+/-34.47) and 268.15 (+/- 32.00) at 3, 6 and 9 days after the surgical procedure, respectively. No corneal or retinal histological changes were observed during the study period. CONCLUSION: The IOL-DDS is effective in delivering therapeutic concentrations of dexamethasone to the aqueous and vitreous, without acute damage to the cornea and retina. Further controlled studies in the same animal model are under way to determine the potential value of this lens in the prevention and treatment of inflammation following cataract surgery.

Animals↗