Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

A validated liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry method for quantitation of cocaine and benzoylecgonine in human plasma.

In order to support studies on various medication protocols for the treatment of cocaine abuse, an accurate, precise, and sensitive (2.5 to 750 ng/mL) liquid chromatography-tandem mass spectrometry assay was developed to determine cocaine and benzoylecgonine in human plasma. Cocaine-d3 and benzoylecgonine-d3 were added as internal standards and samples were subjected to solid-phase extraction. Cocaine recovery was 94.4% and benzoylecgonine was 80.3% at 2.5 ng/mL. The selected reaction monitoring of parent ions at m/z 304 and 290 resulted in strong fragments at m/z 182 and 168 for cocaine and benzoylecgonine, respectively. The method was fully validated. The mean measured concentration at the 2.5 ng/mL, the lower limit of quantitation, was within 10.8% of the target and the precision determined at the low (5 ng/mL), medium (50 ng/mL), and high (650 ng/mL) quality controls ranged from 0.9 to 6.2 %CV. Cocaine and benzoylecgonine concentrations in plasma treated with 1% NaF showed changes of less than 10% when maintained at room temperature for up to 7 h and no significant changes when subjected to three freeze-thaw cycles. The concentrations of cocaine and benzoylecgonine remained stable in plasma samples stored at -20 degrees C for up to 11 months. Methanolic stock solutions of both analytes are stable, staying within 2% of the freshly prepared stock solutions, when stored at -20 degrees C for up to 235 days. Both extracted analytes reconstituted in methanolic solutions are stable for up to seven days whether stored at -20 degrees C or at room temperature on the autosampler. The method is rugged, rapid, and robust and has been applied to the batch analysis of more than 700 samples during pharmacokinetic profiling to assess potential interactions between intravenous (i.v.) cocaine challenge and treament medications. Results from three of these subjects receiving 40 mg (i.v.) cocaine demonstrate the utility of the method.

Adolescent↗

Applicability of capillary electrophoresis to the analysis of trace rare earth elements in geological samples.

This study developed a methodology to analyze trace rare earth elements (REEs) in geological materials by capillary electrophoresis (CE). Changed from dilute HNO3 into a water medium by heating, REE ions are detectable at approximately 2 ng mL(-1). In the presence of coexisting elements from geological samples, REE separations were carried out. After sample fusion with Na2O2 and interference separation with ammonium pyrrolidinedithiocarbamate chelate, REE analytes were coprecipitated with Mg(OH)2 at pH 8.5, and then prepared into a water medium for CE determination. Using the standard addition method, this protocol was validated by analyses with better than 5% precision. This method was applied to geological materials; the REE results are in consistence with their certified values. With electrokinetic injection, internal standard (IS) selected among lanthanides is a prerequisite of high-quality REE data. An approach was proposed to derive the IS content for further correcting its contribution from unknown samples.

Journal Article↗

Optimization of the extraction of azo colorants used in toy products.

Azo dyes are widely used in formulations intended for children use. But their potential toxicity raised the need of an efficient and fast method of analysis. A study for the optimization of the extraction of some azo colorants used in toys was conducted. Several extraction methods for the selected analytes were evaluated and compared, i.e., supercritical fluid extraction (SFE), microwave-assisted extraction (MAE) and Soxhlet extraction. Poly(vinyl chloride) samples spiked with known quantities of the studied dyes were prepared. The influence of critical variables on analyte recoveries in SFE and MAE was investigated by using a full-level factorial design, where most significant parameters as well as order interactions were studied in each case. The analytes were subsequently detected by high-performance liquid chromatography with UV detection. The three extraction techniques were compared in terms of reproducibility, selectivity and analyte recoveries. MAE showed higher recoveries (above 98%), except for the diazo dye (nearly 60%). Reproducibilities were generally good for the three methods (relative standard deviation lower than 2.0%).

Azo Compounds↗

Novel stir bar sorptive extraction methods for environmental and biomedical analysis.

Stir bar sorptive extraction (SBSE) is sample preparation technique that involves the extraction and enrichment of organic compounds from a liquid sample. The technique is based on the principle of sorptive extraction. A large amount of extraction phase is coated on a stir bar. An analyte is extracted into the extraction phase, based on its octanol-water partitioning coefficient and the phase ratio. Recently, various methods involving SBSE were developed in order to further facilitate analysis and improve sensitivity. In this review, we focused on the novel methods that involve SBSE with in situ derivatization, SBSE with in situ de-conjugation, thermal desorption (TD) in the multi-shot mode and TD with in tube derivatization method. Those methods were applied successfully to the trace analysis of environmental and biological samples and extremely low detection limits were achieved.

Animals↗

Fully automated 96-well liquid-liquid extraction for analysis of biological samples by liquid chromatography with tandem mass spectrometry.

A fully automated high-throughput liquid-liquid extraction (LLE) methodology has been developed for preparation of biological samples using a 96-well LLE plate and a 96-channel robotic liquid handling workstation. The 96-well LLE plate is made of a 96-well filter plate filled with inert diatomaceous earth particles, allowing continuous and efficient extraction of analytes between the aqueous biological sample and the organic extraction solvent. Two carboxylic acid-based protease inhibitor compounds with high and low levels of plasma protein binding were chosen for the development and application of the automated methodology. The LLE extracts of the plasma samples of the two compounds were analyzed by high-performance liquid chromatography with electrospray (ESI) tandem mass spectrometry (LC-MS/MS). The LC-MS/MS method was developed using a rapid gradient LC separation, followed by sample introduction through an ionspray interface in the negative ion mode and tandem mass spectrometric detection with selected reaction monitoring. In the optimized LLE method, a formate buffer solution was first loaded into a 96-well filter plate packed with inert diatomaceous earth material. Then crude plasma samples and a water-immiscible organic solvent, methyl ethyl ketone, were sequentially added to the LLE plate so that LLE would occur in the interface between the two liquid phases on the surface of individual particles in each well. The organic eluate containing extracted analytes was evaporated and reconstituted for LC-MS/MS analysis. This fully automated LLE methodology avoids several disjointed steps involved in a manual or semiautomated LLE method, leading to significantly reduced sample preparation time, increased sample throughput, and clean sample extracts for improved ESI-MS/MS detection. The automated LLE methodology is universal and can be employed for sample preparation of other biological fluids. The complete bioanalytical method, based on the automated LLE and fast gradient LC-MS/MS, was validated and successfully applied to the quantitative analysis of protease inhibitors in rat plasma.

Animals↗

Preparative ion-exchange high-performance liquid chromatography of bacterial ribosomal proteins.

We have developed analytical and preparative ion-exchange HPLC methods for the separation of bacterial ribosomal proteins. Proteins separated by the TSK SP-5-PW column were identified with reverse-phase HPLC and gel electrophoresis. The 21 proteins of the small ribosomal subunit were resolved into 18 peaks, and the 32 large ribosomal subunit proteins produced 25 distinct peaks. All peaks containing more than one protein were resolved using reverse-phase HPLC. Peak volumes were typically a few milliliters. Separation times were 90 min for analytical and 5 h for preparative columns. Preparative-scale sample loads ranged from 100 to 400 mg. Overall recovery efficiency for 30S and 50S subunit proteins was approximately 100%. 30S ribosomal subunit proteins purified by this method were shown to be fully capable of participating in vitro reassembly to form intact, active ribosomal subunits.

Bacterial Proteins↗

Rapid gas chromatographic method for simultaneous determination of cholesterol and alpha-tocopherol in eggs.

A new method was developed for simultaneous determination of cholesterol and alpha-tocopherol in eggs. It involves rapid and simple sample preparation accomplished in one tube and chromatographic separation that does not require derivatization of analytes. Total analysis time per sample is 40 min. Labor, cost, and use of hazardous chemicals are minimized. To ensure selectivity, accuracy, and precision, critical analytical parameters were investigated. Overall recoveries were 98.8 and 99.2% for cholesterol and alpha-tocopherol, respectively. Linearity was acceptable for both analytes (r = 0.9964 for cholesterol and 0.9996 for alpha-tocopherol) in the fortification range examined. Precision data based on within-day and between-days variation gave overall relative standard deviations of 2.0% for cholesterol and 7.0% for alpha-tocopherol. The method was applied successfully for quantitation of cholesterol and alpha-tocopherol in eggs.

Calibration↗

Quantitation of dolastatin-10 using HPLC/electrospray ionization mass spectrometry: application in a phase I clinical trial.

A highly sensitive and specific assay for the quantitation of the anticancer agent dolastatin-10 (DOL-10) in human plasma is described. The method was based on the use of electrospray ionization-high-performance liquid chromatography/mass spectrometry (ESP-LC/MS). The analytical procedure involved extraction of plasma samples containing DOL-10 and the internal standard (DOL-15) with n-butyl chloride, which was then evaporated under nitrogen. The residue was dissolved in 50 microl mobile phase and 10 microl was subjected to ESP-LC/MS analysis using a C18 microbore column. A linear gradient using water/acetonitrile was used to keep the retention times of the analytes of interest under 5 min. The method exhibited a linear range from 0.005 to 50 ng/ml with a lower limit of quantitation (LLQ) at 0.005 ng/ml. Absolute recoveries of extracted samples in the 85-90% range were obtained. The method's accuracy (< or =5% relative error) and precision (< or =10% CV) were well within industry standards. The analytical procedure was applied to extract DOL-10 metabolites from samples obtained following incubation of the drug with an activated S9 rat liver preparation. Two metabolic products were detected and were tentatively identified as a N-demethyl-DOL-10 and hydroxy-DOL-10. Structural assignments were made based on the fragmentation patterns obtained using the electrospray source to produce collision-induced dissociation (CID). The method was also applied to the measurement of DOL-10 in the plasma of patients treated with this drug. Preliminary investigation of the pharmacokinetics suggested that drug distribution and elimination may be best described by a three-compartment model with t1/2alpha = 0.087 h, t1/2beta = 0.69 h and t1/2gamma = 8.0 h. Plasma clearance was 3.7 l/h per m2.

Antineoplastic Agents↗

A field method for sampling benzene in end-exhaled air.

A simple and reliable field method is presented for sampling and analysis of benzene in end-exhaled air. The sample is collected directly on an adsorbent tube while the subject exhales through a sampling device consisting of a modified peak expiratory flow meter. To ensure sampling of end-exhaled air, the temperature of the breath is monitored during expiration. The analytes subsequently are thermally desorbed and analyzed by gas chromatography. No sample preparation before analysis is needed, and therefore sample loss is minimized, shipping is easy, storage is possible, and clean up is unnecessary. All these steps have been major problems in earlier methods for breath analysis. The presented method has been applied to the monitoring of benzene. The separation of benzene from other components of exhaled air was good and the detection limit low (0.5 microgram/m3), and therefore benzene could be monitored in occupationally nonexposed nonsmokers. No carry-over in the sampling device or breakthrough could be detected. The samples were stable for at least a week. The combined precision in sampling and analysis was excellent, with a coefficient of variation of 13%.

Adsorption↗

Solid-phase extraction and direct high-performance liquid chromatographic determination of metoprolol enantiomers in plasma.

A method is described by which underivatized metoprolol enantiomers in plasma can be quantitated by high-performance liquid chromatography with fluorescence detection. Samples are prepared for injection using a simple solid-phase extraction procedure which is essentially 100% efficient for all analytes. The metoprolol enantiomers are resolved using a cellulose tris(3,5-dimethylphenylcarbamate) chiral stationary phase and a hexane-ethanol-diethylamine mobile phase. Samples were tested for adaptability to autoinjection and found to be stable for at least 16 h after reconstitution in mobile phase. The automated method was determined to be precise and accurate for enantiomer concentrations as low as 10 ng base per ml and was successfully employed in a pharmacokinetic investigation.

Chromatography, High Pressure Liquid↗

Rapid determination of solanesol in tobacco by high-performance liquid chromatography with evaporative light scattering detection following microwave-assisted extraction.

Solanesol is the starting material for many high-value biochemicals, including coenzyme Q(10) and Vitamin-K analogues. The aim of the current study was to develop a reliable and fast analytical procedure for the determination of solanesol in tobacco using high-performance liquid chromatography (HPLC) with evaporative light scattering detection (ELSD) coupled with microwave-assisted extraction (MAE) as an efficient sample preparation technique. The HPLC conditions were Agilent C18 column using acetonitrile-isopropanol (60:40, v/v) as mobile phase at a flow rate of 1 ml/min. ELSD conditions were optimized at nebulizer-gas flow rate of 1.5 l/min and drift tube temperature of 65 degrees C. The method was validated to achieve the satisfactory precision and recovery, and the calibration range was 0.1-1.5 mg/ml. The developed analytical procedure was successfully applied to determine solanesol content in tobacco samples from different growing regions in China.

Chemical Fractionation↗

Electroanalytical method for determination of the pesticide dichlorvos using gold-disk microelectrodes.

This paper reports the use of laboratory-prepared gold microelectrodes and square-wave voltammetry for analytical determination of low concentrations of the pesticide dichlorvos in pure and natural water samples. After optimization of the experimental and voltammetric conditions, the best voltammetric responses-current intensity and voltammetric profile-were obtained in 0.1 mol L(-1) NaClO4 with f=100 s(-1), a=50 mV, and DeltaE(s)=2 mV. The observed detection and quantification limits in pure water were 7.8 and 26.0 microg L(-1), respectively. The reproducibility and repeatability of the method were also determined; the results were 1.4% (n=5) and 1.2% (n=10), respectively. Possible interfering effects were evaluated in natural water samples collected at different points with different levels of contamination from agricultural, domestic, or industrial waste from an urban stream. Results showed that the detection and quantification limits increased as a function of the quantity of organic matter present in the samples. Nonetheless, the values observed for these method characteristics were below the maximum value allowed by the Brazilian code for organophosphorus pesticides in water samples. Recovery curves constructed using the standard addition method were shown to be satisfactory compared with those obtained from high-performance liquid chromatography, confirming the suitability of the method for analysis of natural water samples. Finally, when the method was used to determine dichlorvos in spiked cows' milk samples, satisfactory recovery and relative standard deviations were obtained.

Animals↗

Preliminary investigation of near-infrared spectroscopic measurements of urea, creatinine, glucose, protein, and ketone in urine.

OBJECTIVE: We investigated the use of near-infrared spectroscopy as an analytical tool to quantify concentrations of urea, creatinine, glucose, ketone, and protein in urine. DESIGN AND METHODS: FT-IR spectroscopy in conjunction with a polynomial based spectral smoothing method was applied to urine specimens. A partial factorial experimental design was employed to collect spectra using normal and spiked urine samples. RESULTS: Our results show that the spectral signatures of urea, creatinine, glucose, ketone, and protein in the 1350 to 1800 nm and 2050 to 2375 nm range are sufficiently strong and unique for accurate measurements. CONCLUSIONS: The accuracy of near infrared for quantifying concentrations of urea and creatinine is only slightly less than our selected reference methods. Glucose, ketone and protein are sufficiently accurate to be useful as a screening tool for wellness. The method successfully accounts for biologic matrix variation. The advantages of near-infrared analysis are (1) no reagents, (2) ease of sample preparation, (3) speed, and (4) the ability to quantify multiple analytes with one spectra.

Calibration↗

Comparison of packed-column supercritical fluid chromatography--tandem mass spectrometry with liquid chromatography--tandem mass spectrometry for bioanalytical determination of (R)- and (S)-ketoprofen in human plasma following automated 96-well solid-phase extraction.

The popularity of packed-column supercritical fluid, subcritical fluid, and enhanced fluidity liquid chromatographies (pcSFC) for enantiomeric separations has increased steadily over the past few years. The addition of a significant amount (typically 20-95%) of a viscosity lowering agent, such as carbon dioxide, to the mobile phase provides a number of advantages for chiral separations. For example, higher mobile-phase flow rates can often be attained without a concomitant loss in chromatographic efficiency since diffusion coefficients, and optimum velocities, are typically higher in pcSFC. Ultratrace enantioselective quantitation of drugs in biomatrixes is an ideal application for these chromatographic attributes. To demonstrate the utility of this approach, a pcSFC tandem mass spectrometry (pcSFC-MS/MS) method was compared to a LC-MS/MS method for quantitation of the (R)- and (S)-enantiomers of ketoprofen (kt), a potent nonsteroidal, anti-inflammatory drug, in human plasma. After preparation using automated solid-phase extraction in the 96-well format, kt enantiomers were separated on a Chirex 3005 analytical column using isocratic conditions. Validation data and study sample data from patients dosed with either orally or topically administered ketoprofen were generated using both pcSFC and LC as the chromatographic methods to compare and contrast these analytical approaches. Generally, most analytical attributes, including specificity, linearity, sensitivity, accuracy, precision, and ruggedness, for both of these methods were comparable with the exception that the pcSFC separation provided a roughly 3-fold reduction in analysis time. A 2.3-min pcSFC separation and a 6.5-min LC separation provided equivalent, near-baseline-resolved peaks, demonstrating a significant time savings for analysis of large batch pharmacokinetic samples using pcSFC.

Anti-Inflammatory Agents, Non-Steroidal↗

Determination of Salvinorin A in body fluids by high performance liquid chromatography-atmospheric pressure chemical ionization.

Salvinorin A was quantitated in human and rhesus monkey plasma, rhesus monkey cerebrospinal fluid, and human urine by negative ion LC-MS/APCI. The method for Salvinorin A has been fully validated, the LLOQ using FDA guidelines is 2 ng/mL for 0.5 mL plasma samples. The linear range was from 2 to 1000 ng/mL. Several derivatives in the Salvinorin family can also be analyzed by this method; d(3)-Salvinorin A was prepared and used as internal standard. The metabolite Salvinorin B can be semi quantitatively determined. The method has been used to establish that Salvinorin B is the principal metabolite of Salvinorin A ex vivo and to establish the analytical method to study in vivo samples.

Animals↗

Tackling matrix effects during development of a liquid chromatographic-electrospray ionisation tandem mass spectrometric analysis of nine basic pharmaceuticals in aqueous environmental samples.

When developing an LC-MS/MS-method matrix effects are a major issue. The effect of co-eluting compounds arising from the matrix can result in signal enhancement or suppression. During method development much attention should be paid to diminish matrix effects as much as possible. The present work evaluates matrix effects from aqueous environmental samples in the simultaneous analysis of a group of nine specific pharmaceuticals with LC-ESI/MS/MS: flubendazole, propiconazole, pipamperone, cinnarizine, ketoconazole, miconazole, rabeprazole, itraconazole and domperidone. Solutions to diminish signal suppression were examined: optimisation of the sample preparation, decrease of the flow rate, and the use of appropriate internal standards. Several SPE-stationary phases were tested in view of retention of the analytes: Oasis HLB, C8, Phenyl, Strata X-polymer RP sorbent and Strata X-polymeric SCX/RP sorbent. Oasis HLB showed the best retention for all analytes. The Oasis HLB SPE-method was optimised, but analyses showed high matrix suppression. Therefore, a second SPE-method, on a phenyl stationary phase (the second best option), was also optimised. A comparison of the matrix effect was made between the two procedures: the phenyl-method was less subject to matrix effects, however, the average matrix effect (ME%) of 46% indicated that matrix effects where still present. Several optimisation options for the phenyl-method were evaluated: addition of a ferric nitrate solution before extraction, application of an alkaline wash step, and use of a second SPE-cartridge, either a NH2-column or a florisil column. A more efficient sample clean-up was achieved by applying the extract after extraction on the phenyl column and after dilution with chloroform, onto a NH2-column (average ME%: 53%). In addition, applying a post-column split (1:5), further reduced matrix effects (average ME%: 65%). Labelled internal standards are the best way to tackle matrix effects, but no such internal standards were commercially available for the analytes of interest. The thorough search and application of four internal standards (structural analogues) was beneficial and compensates the matrix effect partially (average ME%: 83%). In an attempt to reduce the analysis time Speedisk phenyl columns were applied. Under these conditions matrix effects decreased even more while recoveries were between 91 and 109%. Different kinds of surface water samples were analyzed, and different matrix effects were observed. For this reason, standard addition will be used to perform quantitative analysis.

Chromatography, Liquid↗

Separations of basic amino acid benzyl esters by pH-zone-refining counter-current chromatography.

pH-Zone-refining counter-current chromatography was applied to the separation of basic amino acid benzyl esters. The method uses a retainer base in the stationary phase to retain analytes in the column and an eluent acid to elute the analytes in the decreasing order of pKa and hydrophilicity. The preparative capability of the method is demonstrated in the separation of a 10-g quantity of the sample.

Amino Acids↗

High-performance liquid chromatographic assay for amiodarone N-deethylation in microsomes of rat liver.

A reversed-phase high-performance liquid chromatographic assay using ultraviolet detection is described for determining the production of the major N-dealkylated metabolite of amiodarone in rat liver microsomes. The principal advantages of this method are its simple sample preparation (protein precipitation by acetonitrile), low detection limit for N-desethylamiodarone (0.05 mumol/l) and relatively short analysis time (16 min). Its analytical applicability is demonstrated by the comparison of the kinetic parameters (maximum velocity and Michaelis-Menten constant) between Sprague-Dawley and Dark-Agouti rats.

Amiodarone↗