Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “dynamic range”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32Linked to original sources

Chemiluminescence detection for hybridization assays on the flow-thru chip, a three-dimensional microchannel biochip.

Chemiluminescence (CL) detection is seldom used in two-dimensional solid support microarray platforms because adequate sensitivity and spatial resolution is difficult to achieve. The three-dimensional ordered microchannels of the Flow-thru Chip increase both the sensitivity and spatial resolution required for quantitative CL measurements on microarrays. Enzyme-catalyzed CL reactions for the detection of hybridizations on microchannel glass were imaged using a CCD camera. Signal uniformity, sensitivity, and dynamic range of the detection method were determined. The relative standard deviation of signal intensities across an array of 64 spots was 8.1%. A detection limit of 250 amol of target with a linear dynamic range of 3 orders of magnitude was obtained for a 3-h assay. Similar to two-color fluorescence measurements, multiple enzyme labels were employed to demonstrate two-channel chemiluminescence. A unique method for measuring the relaxation time of a chemiluminescent species is also described.

Calibration↗

Noise shaping in populations of coupled model neurons.

Biological information-processing systems, such as populations of sensory and motor neurons, may use correlations between the firings of individual elements to obtain lower noise levels and a systemwide performance improvement in the dynamic range or the signal-to-noise ratio. Here, we implement such correlations in networks of coupled integrate-and-fire neurons using inhibitory coupling and demonstrate that this can improve the system dynamic range and the signal-to-noise ratio in a population rate code. The improvement can surpass that expected for simple averaging of uncorrelated elements. A theory that predicts the resulting power spectrum is developed in terms of a stochastic point-process model in which the instantaneous population firing rate is modulated by the coupling between elements.

Mathematics↗

GABAergic inhibition and the effect of sound direction on rate-intensity functions of inferior collicular neurons of the big brown Bat, Eptesicus fuscus.

GABAergic inhibition shapes many auditory response properties of neurons in the inferior colliculus of the big brown bat, Eptesicus fuscus. This study examined the role of GABAergic inhibition on direction-dependent rate-intensity functions of bat inferior collicular neurons. When plotted at three sound directions (60 degrees contralateral, 0 degrees and 60 degrees ipsilateral relative to recording site), most collicular neurons had nonmonotonic and saturated rate-intensity functions at 60 degrees contralateral and 0 degrees but had monotonic rate-intensity functions at 60 degrees ipsilateral. The dynamic range of rate-intensity functions of majority (>90%) of collicular neurons significantly decreased as the sound direction changed from 60 degrees contralateral to 60 degrees ipsilateral. Bicuculline application increased or decreased the dynamic range of IC neurons in different degrees with sound direction and abolished direction-dependent intensity sensitivity of these IC neurons. Possible mechanisms for these observations are discussed.

Animals↗

Development of an Alu-based, real-time PCR method for quantitation of human DNA in forensic samples.

Determining the amount of human DNA extracted from a crime scene sample is an important step in DNA profiling. The forensic community relies almost entirely upon a technique (slot blot) to quantitate human DNA that is imprecise, time consuming, and labor intensive. We have previously described a method for quantitation of human DNA based on PCR amplification of a repetitive Alu sequence that uses a fluorescence plate reader. This manuscript describes and validates a variation of this assay using real-time PCR and SYBR Green I for quantitation. The advantages of the real-time assay over the plate reader assay are: reduced hands-on time, lower assay cost, and a greater dynamic range. The main disadvantage is the cost of the real-time instrument. However, for those forensic laboratories with access to a real-time instrument, this Alu-based assay has a dynamic range of 16 ng to 1 pg, is sensitive, specific, fast, quantitative, and uses only 2 microL of sample.

Alu Elements↗

Neurophysiology of nociception and pain in the spinal cord.

Our experiments on the primate spinothalamic tract cells are consistent with the traditional view that the spinothalamic tract in primates is the main pathway responsible for pain sensation. However, we have no evidence concerning the possible role of other pathways, either in pain sensation or in the motivational-affective or reflex responses to painful stimuli. At least two different classes of spinothalamic tract cells, the high-threshold and the wide-dynamic-range neurons, appear to be involved in nociception, although they may well play different roles. High-threshold spinothalamic cells seem well suited to signal stimulus location, as well as intensity. Wide-dynamic-range cells can signal intensity, but they are not likely to provide good spatial resolution of stimuli. On the contrary, they are well suited to explain such phenomena as referred pain and pain radiation.

Animals↗

Flat detectors and their clinical applications.

Diagnostic and interventional flat detector X-ray systems are penetrating the market in all application segments. First introduced in radiography and mammography, they have conquered cardiac and general angiography and are getting increasing attention in fluoroscopy. Two flat detector technologies prevail. The dominating method is based on an indirect X-ray conversion process, using cesium iodide scintillators. It offers considerable advantages in radiography, angiography and fluoroscopy. The other method employs a direct converter such as selenium which is particularly suitable for mammography. Both flat detector technologies are based on amorphous silicon active pixel matrices. Flat detectors facilitate the clinical workflow in radiographic rooms, foster improved image quality and provide the potential to reduce dose. This added value is based on their large dynamic range, their high sensitivity to X-rays and the instant availability of the image. Advanced image processing is instrumental in these improvements and expand the range of conventional diagnostic methods. In angiography and fluoroscopy the transition from image intensifiers to flat detectors is facilitated by ample advantages they offer, such as distortion-free images, excellent coarse contrast, large dynamic range and high X-ray sensitivity. These characteristics and their compatibility with strong magnetic fields are the basis for improved diagnostic methods and innovative interventional applications.

Absorption↗

Comparison of detection methods for liquid chromatographic determination of 3-nitro-L-tyrosine.

A liquid chromatographic method has been developed for the determination of 3-nitro-L-tyrosine. Different detection methods, including UV, oxidative and redox electrochemistry, and postcolumn photolysis followed by electrochemical detection, have been optimized and compared in terms of analysis time, detection limit and dynamic range. It was demonstrated that liquid chromatography with postcolumn photolysis followed by electrochemical detection is the most effective method, with an analysis time of 5 min, detection limit of 0.01 pmol, and a linear dynamic range from 2 nM to 100 microM.

Animals↗

Quantitation of HTLV-I and II proviral load using real-time quantitative PCR with SYBR Green chemistry.

BACKGROUND: Human T-lymphotropic virus type I (HTLV-I) is linked etiologically with adult T cell leukemia/lymphoma and HTLV-I-associated myelopathy/tropical spastic paraparsis (HAM/TSP). Human T-lymphotropic virus type II (HTLV-II) is associated with HAM/TSP and, in HIV coinfected patients only, rare cases of cutaneous T cell lymphoma. Proviral load may be important in the pathogenesis of HTLV-associated disease. MATERIALS AND METHODS: A real time quantitative PCR assay using SYBR Green intercalation was established. Primers targeting the tax region were standardized against MT2 and MOT cell line DNA for HTLV-I and HTLV-II, respectively. HTLV-I/II copy number was normalized to the amount of cellular DNA by quantitation of the HLA-DQ alpha gene. We measured proviral load in peripheral blood mononuclear cells (PBMCs) in a large cohort of 120 HTLV-I and 335 HTLV-II seropositive former blood donors. We also assessed the intra- and inter-assay reproducibility of the assay. RESULTS: Proviral load for HTLV-I infected patients ranged from 3.1 x 10(0) to 1.8 x 10(5)copies/10(6) PBMCs with a mean of 1.6 x 10(4) and a median of 3.0 x 10(3). HTLV-I was undetectable in 7 of 120 cases (5.8%). Proviral load for HTLV-II infected patients ranged from 1.1 x 10(0) to 1.0 x 10(6)copies/10(6) PBMCs with a mean of 2.8 x 10(4) and a median of 5.0 x 10(2). HTLV-II was undetectable in 31 out of 335 cases (9.3%). CONCLUSION: The assay has excellent dynamic range from 10(6) to 10(0)copies/reaction, good intra- and inter-assay reproducibility, and a lower limit of detection of a single copy per reaction. The sensitivity and high dynamic range allow determination of a broad range of HTLV-I/II proviral load in clinical subjects. This assay will facilitate the study of the relationship between proviral load and pathogenesis.

Benzothiazoles↗

Behavior of a polypyrrole solid contact pH-selective electrode based on tertiary amine ionophores containing different alkyl chain lengths between nitrogen and a phenyl group.

We compared the slopes of the EMF responses and the response range of a solid contact electrode based on a tribenzylamine ionophore with those based on a tris(2-phenylethyl)amine ionophore and a tris(3-phenylpropyl)amine ionophore. Their slopes of the EMF responses showed, respectively, 57.7, 58.1, 59.0 mV pH(-1) (at 20 +/- 0.2 degrees C). Also, the linear pH response dynamic ranges were 2.74-10.63 for tribenzylamine-based SCEs, pH 4.47-12.59 for tris(2-phenylethyl)amine, and pH 4.60-13.24 for tris(3-phenylpropyl)amine. When the slopes of the EMF responses and the response range were considered, as the length of the replaced alkyl chain increased between the nitrogen atom and the phenyl group in the ionophore, though the dynamic range and the slopes of the EMF responses of these electrodes did not show any particularly different results, their response ranges moved toward the alkali range (shifted to pH 14). When it was directly applied to cow's milk (in pH range of 6.0-8.5), we could obtain the same satisfying results. This electrode continuously contacted a Tris 7.50 buffered solution as well as cow's milk for one month without any loss of performance. Also, especially, these electrodes showed very good results, such as stabilization of the base potential as well as the best reproducibility and response time (< 10 s).

Journal Article↗

Simultaneous spectrofluorimetric and spectrophotometric determination of melatonin and pyridoxine in pharmaceutical preparations by multivariate calibration methods.

Partial least-squares (PLS) calibration and principal component regression (PCR) methods were utilized for the simultaneous spectrofluorimetric and spectrophotometric determination of pyridoxine (PY) and melatonin (MT). Since emission and adsorption spectra of these drugs overlap, PY and MT cannot be directly determined by fluorimetric nor by spectrophotometric methods. Full-spectrum multivariate calibration PLS and PCR methods were developed for both fluorimetry and spectrophotometry. The conditions were optimized for fluorimetric as well as for spectrophotometric determination of both drugs. The simultaneous determination of PY and MT was carried out in mixtures by recording the emission fluorescence spectrum between 324 and 500 nm (lambda(ex) 285 nm) for fluorimetry, and by recording the absorption spectrum between 250 and 350 nm for spectrophotometry (lambda(max(PY)) 310 nm, lambda(max(MT)) 278 nm). The experimental calibration matrixes were designed orthogonally. At the optimum conditions, dynamic ranges were 0.04-1.3 and 0.1-4 microg ml(-1) for fluorimetry and 1-22 and 1-24 microg ml(-1) for spectrophotometry for MT and PY, respectively. The calibration concentrations were prepared in the dynamic ranges. The parameters of the chemometrics procedure for the simultaneous determination of MT and PY were optimized, and the proposed methods were validated with prediction set. Finally the procedures were successfully applied to simultaneous spectrofluorimetric and spectrophotometric determination of PY and MT in synthetic mixtures and in a pharmaceutical formulation.

Chemistry, Pharmaceutical↗

Development of an electrochemical immunosensor for direct detection of interferon-gamma at the attomolar level.

An electrochemical immunosensor for direct detection of the 15.5-kDa protein interferon-gamma (IFN-gamma) at attomolar level has been developed. Self-assembled monolayers (SAMs) of cysteine or acetylcysteine are formed on electropolished polycrystalline Au electrodes. IFN-gamma adsorbs physically to each of these SAMs. With injections of 100 mM KCl, IFN-gamma can be removed in the flow without damaging the acetylcysteine SAM. However, the cysteine SAM is affected by these KCl injections. In an on-line procedure in the flow, a specific antibody (MD-2) against IFN-gamma is covalently attached following carbodiimide/succinimide activation of the SAM. The activation of the carboxylic groups, attachment of MD-2, and deactivation of the remaining succinimide groups with ethanolamine are monitored impedimetrically at a frequency of 113 Hz, a potential of +0.2 V versus SCE, and an ac modulation amplitude of 10 mV. Plots of the real (Z') and imaginary (Z") component of the impedance versus time provide the information to control these processes. In the thermostated setup (23.0 degrees C), samples of unlabeled IFN-gamma (in phosphate buffer pH 7.4) are injected and the binding with immobilized MD-2 is monitored with ac impedance or potential-step methods. While the chronoamperometric results are rather poor, the ac impedance approach provides unsurpassed detection limits, as low as 0.02 fg mL-1 (approximately 1 aM) IFN-gamma. From a calibration curve (i.e. Z" versus the amount injected), recorded by multiple 50-microL injections of 2 pg mL(-1) of IFN-gamma, a dynamic range of 0-12 pg mL(-1) could be derived. However, when nonspecific adsorption is taken into account, which has been found to be largely reduced through injections of 100 mM KCl, a much smaller dynamic range of 0-0.14 fg mL(-1) remains. The immunosensor can be regenerated by using a sequence of potential pulses in the flow by which the SAM with attached MD-2 and bound IFN-gamma is completely removed. When the developed procedures described above are repeated, the response of the immunosensor is reproducible within 10%.

Acetylcysteine↗

Comparison of the Chiron Quantiplex branched DNA (bDNA) assay and the Abbott Genostics solution hybridization assay for quantification of hepatitis B viral DNA.

Several assays for quantification of DNA have been developed and are currently used in research and clinical laboratories. However, comparison of assay results has been difficult owing to the use of different standards and units of measurements as well as differences between assays in dynamic range and quantification limits. Although a few studies have compared results generated by different assays, there has been no consensus on conversion factors and thorough analysis has been precluded by small sample size and limited dynamic range studied. In this study, we have compared the Chiron branched DNA (bDNA) and Abbott liquid hybridization assays for quantification of hepatitis B virus (HBV) DNA in clinical specimens and have derived conversion factors to facilitate comparison of assay results. Additivity and variance stabilizing (AVAS) regression, a form of non-linear regression analysis, was performed on assay results for specimens from HBV clinical trials. Our results show that there is a strong linear relationship (R2 = 0.96) between log Chiron and log Abbott assay results. Conversion factors derived from regression analyses were found to be non-constant and ranged from 6-40. Analysis of paired assay results below and above each assay's limit of quantification (LOQ) indicated that a significantly (P < 0.01) larger proportion of observations were below the Abbott assay LOQ but above the Chiron assay LOQ, indicating that the Chiron assay is significantly more sensitive than the Abbott assay. Testing of replicate specimens showed that the Chiron assay consistently yielded lower per cent coefficients of variance (% CVs) than the Abbott assay, indicating that the Chiron assay provides superior precision.

DNA, Viral↗

Corticofugal modulation of midbrain sound processing in the house mouse.

An understanding of the neural mechanisms responsible for auditory information processing is incomplete without a careful examination of substantial descending pathways. This study focuses on the functional role of corticofugal projections. Our work with the house mouse reveals that the focal electrical stimulation of the primary auditory cortex leads to profound changes in auditory response properties in the central nucleus of the inferior colliculus of the midbrain. Cortical stimulation does not impact on the collicular best frequencies when the best frequencies of stimulated cortical neurons and recorded collicular neurons are similar. Rather, collicular best frequencies are shifted toward the stimulated cortical best frequencies when cortical and collicular frequencies are different. Such a shift is unrelated to the differences in minimum thresholds between cortical and collicular neurons. In addition to frequency-specific shifts in collicular best frequencies, cortical stimulation elevates collicular minimum thresholds and reduces both dynamic ranges and response magnitudes if cortical and collicular best frequencies are different. If cortical and collicular best frequencies are similar but minimum thresholds are different, collicular minimum thresholds are shifted toward the stimulated cortical thresholds; dynamic ranges and response magnitudes may either increase or decrease in this scenario. Our results suggest that the corticofugal adjustment has a centre-surround organization with regard to both cortical best frequencies and cortical minimum thresholds. The midbrain processing of sound components in the centre of cortical feedback is largely enhanced while processing in the surround is suppressed.

Acoustic Stimulation↗

[Examination of the constancy of the medium optical density of conventional chest radiographs].

PURPOSE: To determine whether the medium optical density of conventional chest radiographs is constant. MATERIALS AND METHODS: 47 PA chest radiographs were digitized to measure the optical density and its dynamic range of normal and pathologically altered lungs. RESULTS: For constant exposure factors and a correctly positioned region of interest, the medium optical density deviates only minimal despite differences in AP chest diameter, entry dose and dynamic range, and is largely independent of the pathologic pulmonary findings. CONCLUSION: Digitization of the radiograph enables the determination of the physical parameters used to operate the imaging system, such as medium optical density, image contrast, image latitude and density distribution, in accordance to the guidelines of the German Medical Association. If the region of interest encompasses the clinically relevant region of the lung, the measured value of the optical density corresponds with only minor variation to the average value of the entire lung region.

Absorptiometry, Photon↗

Comparison of real-time polymerase chain reaction and end-point polymerase chain reaction for the analysis of gene expression in preimplantation embryos.

The aim of the present study was to compare real-time polymerase chain reaction (PCR) and end-point PCR with respect to their suitability for the analysis of gene expression in samples in which the number of cells is limited; for example, in studies of preimplantation embryonic development and to determine the variability of the real-time reverse transcription-PCR assay. The sensitivity, dynamic range and precision of both PCR systems were compared using a single mouse liver cDNA standard. The real-time system was 100-fold more sensitive than the end-point system and had a dynamic range of more than four orders of magnitude. The linear range for end-point PCR extended for two orders of magnitude using a fixed end-point of 31 cycles. The percentage standard error of the mean based on 30 replicates was 0.14% of the threshold cycle (Ct) value for the real-time system and 6.8% for the end-point fluorescence intensity. The coefficients of variation (CV) for reverse transcription combined with real-time analysis and the complete gene expression protocol consisting of mRNA isolation, reverse transcription and real-time PCR analysis were 0.6% and 1.4% of the Ct values, respectively. The present paper details, for the first time, measurement of the biological variation of individual mammalian oocytes. The CV was 1.8% of the Ct value for expression analysis of six bovine oocytes. The results are discussed in relation to the analysis of gene expression in preimplantation embryo development.

Animals↗

Pseudo-polar drive patterns for brain electrical impedance tomography.

Brain electrical impedance tomography (EIT) is a difficult task as brain tissues are enclosed by the skull of high resistance and cerebrospinal fluid (CSF) of low resistance, which makes internal resistivity information more difficult to extract. In order to seek a single source drive pattern that is more suitable for brain EIT, we built a more realistic experimental setting that simulates a head with the resistivity of the scalp, skull, CSF and brain, and compared the performance of adjacent, cross, polar and pseudo-polar drive patterns in terms of the boundary voltage dynamic range, independent measurement number, total boundary voltage changes and anti-noise performance based on it. The results demonstrate that the pseudo-polar drive pattern is optimal in all the aspects except for the dynamic range. The polar and cross drive patterns come next, and the adjacent drive pattern is the worst. Therefore, the pseudo-polar drive pattern should be chosen for brain EIT.

Brain↗

Auditory cortical responses to electrical stimulation of the inferior colliculus: implications for an auditory midbrain implant.

The success and limitations of cochlear implants (CIs) along with recent advances in deep brain stimulation and neural engineering have motivated the development of a central auditory prosthesis. In this study, we investigated the effects of electrical stimulation of the inferior colliculus central nucleus (ICC) on primary auditory cortex (A1) activity to determine the potential benefits of an auditory midbrain implant (AMI). We recorded multiunit activity in A1 of ketamine-anesthetized guinea pigs in response to single-pulse (200 micros/phase) monopolar stimulation of the ICC using multisite silicon-substrate probes. We then compared measures of threshold, dynamic range, and tonotopic spread of activation for ICC stimulation with that of published data for CI stimulation. Our results showed that compared with cochlear stimulation, ICC stimulation achieved: 1) thresholds about 8 dB lower; 2) dynamic ranges > or = 4 dB greater; and 3) more localized, frequency-specific activation, even though frequency specificity was partially lost at higher stimulus levels for low-frequency ICC regions. Our results also showed that stimulation of rostral ICC regions elicited lower thresholds but with greater activation spread along the tonotopic gradient of A1 than did stimulation of more caudal regions. These results suggest that an AMI may improve frequency and level coding with lower energy requirements compared with CIs. However, a trade-off between lower perceptual thresholds and better frequency discrimination may exist that depends on location of stimulation along the caudorostral dimension of the ICC. Overall, this study provides the foundation for future AMI research and development.

Acoustic Stimulation↗

A gene expression system offering multiple levels of regulation: the Dual Drug Control (DDC) system.

BACKGROUND: Whether for cell culture studies of protein function, construction of mouse models to enable in vivo analysis of disease epidemiology, or ultimately gene therapy of human diseases, a critical enabling step is the ability to achieve finely controlled regulation of gene expression. Previous efforts to achieve this goal have explored inducible drug regulation of gene expression, and construction of synthetic promoters based on two-hybrid paradigms, among others. RESULTS: In this report, we describe the combination of dimerizer-regulated two-hybrid and tetracycline regulatory elements in an ordered cascade, placing expression of endpoint reporters under the control of two distinct drugs. In this Dual Drug Control (DDC) system, a first plasmid expresses fusion proteins to DBD and AD, which interact only in the presence of a small molecule dimerizer; a second plasmid encodes a cassette transcriptionally responsive to the first DBD, directing expression of the Tet-OFF protein; and a third plasmid encodes a reporter gene transcriptionally responsive to binding by Tet-OFF. We evaluate the dynamic range and specificity of this system in comparison to other available systems. CONCLUSION: This study demonstrates the feasibility of combining two discrete drug-regulated expression systems in a temporally sequential cascade, without loss of dynamic range of signal induction. The efficient layering of control levels allowed by this combination of elements provides the potential for the generation of complex control circuitry that may advance ability to regulate gene expression in vivo.

Animals↗