Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32Linked to original sources

Imaging wound healing using optical coherence tomography and multiphoton microscopy in an in vitro skin-equivalent tissue model.

Laser thermal injury and subsequent wound healing in organotypic, skin-equivalent tissue models were monitored using optical coherence tomography (OCT), multiphoton microscopy (MPM), and histopathology. The in vitro skin-equivalent raft tissue model was composed of dermis with type I collagen and fibroblast cells and epidermis of differentiated keratinocytes. Noninvasive optical imaging techniques were used for time-dependent, serial measurements of matrix destruction and reconstruction and compared with histopathology. The region of laser thermal injury was clearly delineated in OCT images by low signal intensity. High resolution MPM imaging using second-harmonic generation revealed alterations in collagen microstructure organization with subsequent matrix reconstruction. Fibroblast cell migration in response to injury was monitored by MPM using two-photon excited fluorescence. This study illustrates the complementary features of linear and nonlinear light-tissue interaction in intrinsic signal optical imaging and their use for noninvasive, serial monitoring of wound healing processes in biological tissues.

Burns↗

Optical probes and techniques for molecular contrast enhancement in coherence imaging.

Optics has played a key role in the rapidly developing field of molecular imaging. The spectroscopic nature and high-resolution imaging capabilities of light provide a means for probing biological morphology and function at the cellular and molecular levels. While the use of bioluminescent and fluorescent probes has become a mainstay in optical molecular imaging, a large number of other optical imaging modalities exist that can be included in this emerging field. In vivo imaging technologies such as optical coherence tomography and reflectance confocal microscopy have had limited use of molecular probes. In the last few years, novel nonfluorescent and nonbioluminescent molecular imaging probes have been developed that will initiate new directions in coherent optical molecular imaging. Classes of probes reviewed in this work include those that alter the local optical scattering or absorption properties of the tissue, those that modulate these local optical properties in a predictable manner, and those that are detected utilizing spectroscopic optical coherence tomography (OCT) principles. In addition to spectroscopic OCT, novel nonlinear interferometric imaging techniques have recently been developed to detect endogenous molecules. Probes and techniques designed for coherent molecular imaging are likely to improve the detection and diagnostic capabilities of OCT.

Animals↗

Optic nerve sheath meningiomas. Role of MR imaging.

Optic nerve meningiomas usually are seen in middle-aged and elderly women, and present as a slowly progressing axial proptosis and loss of vision. CT and MR imaging are the most valuable diagnostic tools to evaluate these tumors. This article reviews the MR imaging and CT characteristics of optic nerve sheath meningiomas and discusses features that may distinguish optic nerve sheath meningiomas from simulating lesions.

Aged↗

Cell uptake and tissue distribution of radioiodine labelled D-luciferin: implications for luciferase based gene imaging.

Optical luciferase gene imaging is emerging as a method to monitor gene expression in small animals. However, there is concern over how regional availability of exogenously administered substrate may affect photon emission. We thus synthesized [125I]iodo-D-luciferin, which demonstrated substrate characteristics for firefly luciferase, and investigated its cell uptake kinetics and in vivo biodistribution. Luminescence assays of luc gene transduced cells confirmed a linear decline in emitted light units with decreasing luciferin concentration. Both luc gene transduced and control cells demonstrated a low level of cellular uptake and rapid washout of [125I]iodo-D-luciferin, although early uptake was slightly higher for transduced cells (P < 0.005). Biodistribution in ICR mice demonstrated that early uptakes in liver, lung, myocardium and muscle were lower with intraperitoneal compared to intravenous administration. In view of the poor cell uptake, uptake levels (< 3%ID/g) suggest that substrate concentration may limit light emission rates in organs such as bone, muscle, myocardium, and particularly the brain. Thus, substrate availability should be considered as a potential limiting factor for photon emission efficiency in certain organs when attempting quantitative interpretation of optical luc gene imaging.

Animals↗

Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging.

Although optical absorption is strongly associated with the physiological status of biological tissue, existing high-resolution optical imaging modalities, including confocal microscopy, two-photon microscopy and optical coherence tomography, do not sense optical absorption directly. Furthermore, optical scattering prevents these methods from imaging deeper than approximately 1 mm below the tissue surface. Here we report functional photoacoustic microscopy (fPAM), which provides multiwavelength imaging of optical absorption and permits high spatial resolution beyond this depth limit with a ratio of maximum imaging depth to depth resolution greater than 100. Reflection mode, rather than orthogonal or transmission mode, is adopted because it is applicable to more anatomical sites than the others. fPAM is demonstrated with in vivo imaging of angiogenesis, melanoma, hemoglobin oxygen saturation (sO2) of single vessels in animals and total hemoglobin concentration in humans.

Anatomy, Cross-Sectional↗

Imaging of the optic disc and retinal nerve fiber layer: the effects of age, optic disc area, refractive error, and gender.

We cross-sectionally examined the relationship between age, optic disc area, refraction, and gender and optic disc topography and retinal nerve fiber layer (RNFL) measurements, using optical imaging techniques. One eye from each of 155 Caucasian subjects (age range 23.0-80.8 y) without ocular pathology was included. Measurements were obtained by using the Heidelberg Retina Tomography (HRT), the GDx Nerve Fiber Analyzer, and the Optical Coherence Tomograph (OCT). The effects of age were small (R2 < 17%) and were limited to specific HRT, GDx, and OCT parameters. Disc area was significantly associated with most HRT parameters and isolated GDx and OCT parameters. Refraction and gender were not significantly associated with any optic disc or RNFL parameters. Although effects of age on the optic disc and RNFL are small, they should be considered in monitoring ocular disease. Optic disc area should be considered when cross-sectionally evaluating disc topography and, to a lesser extent, RNFL thickness.

Adult↗

Simulation study of magnetic resonance imaging-guided cortically constrained diffuse optical tomography of human brain function.

Diffuse optical imaging can measure brain activity noninvasively in humans through the scalp and skull by measuring the light intensity modulation arising from localized-activity-induced absorption changes within the cortex. Spatial resolution and localization accuracy are currently limited by measurement geometry to approximately 3 cm in the plane parallel to the scalp. Depth resolution is a more significant challenge owing to the limited angle tomography permitted by reflectance-only measurements. We combine previously established concepts for improving image quality and demonstrate, through simulation studies, their application for improving the image quality of adult human brain function. We show in a three-dimensional human head model that localization accuracy is significantly improved by the addition of measurements that provide overlapping samples of brain tissue. However, the reconstructed absorption contrast is significantly underestimated because its depth is underestimated. We show that the absorption contrast amplitude accuracy can be significantly improved by providing a cortical spatial constraint in the image reconstruction to obtain a better depth localization. The cortical constraint makes physiological sense since the brain-activity-induced absorption changes are occurring in the cortex and not in the scalp, skull, and cerebral spinal fluid. This spatial constraint is provided by segmentation of coregistered structural magnetic resonance imaging (MRI). However, the absorption contrast deep within the cortex is reconstructed superficially, resulting in an underestimation of the absorption contrast. The synthesis of techniques described here indicates that multimodality imaging of brain function with diffuse optical imaging and MRI has the potential to provide more quantitative estimates of the total and deoxyhemoglobin response to brain activation, which is currently not provided by either method independently. However, issues of depth resolution within the cortex remain to be resolved.

Algorithms↗

Arranging optical fibres for the spatial resolution improvement of topographical images.

Optical topography is a method for visualization of conical activity. Ways of improving the spatial resolution of the topographical image with three arrangements of optical fibres are discussed. A distribution of sensitivity is obtained from the phantom experiment, and used to reconstruct topographical images of an activation area of the brain with the fibres in each arrangement. The correlations between the activated area and the corresponding topographical images are obtained, and the effective arrangement of the optical fibres for improved resolution is discussed.

Brain↗

Long time echo stir sequence magnetic resonance imaging of optic nerves in optic neuritis.

Magnetic resonance imaging of optic nerves was obtained in 13 patients with acute optic neuritis and in 13 patients with a previous history of optic neuritis (ON), assessed by clinical, visual fields and visual evoked potentials evaluations. Results of the conventional short tau inversion recovery (STIR) sequence obtained with short time echo (STE-STIR: 22 ms) were compared with long time echo (LTE-STIR: 80 ms) sequence. The conventional STE-STIR sequence revealed lesions in 78.5% of acute ON and in 58.8% of optic nerves affected by previous ON. The LTE-STIR sequence was diagnostic in 92.8% of acutely symptomatic nerves, in 94.1% of nerves with previous ON. The calculated length of optic nerve lesions was significantly longer in imaging obtained with the LTE-STIR sequence than with the conventional STE-STIR sequences, both in acute and previous ON.

Adult↗

Long time echo STIR sequence magnetic resonance imaging of optic nerves in optic neuritis.

Magnetic resonance images of optic nerves were obtained in 20 patients with acute optic neuritis (ON), and assessed by means of clinical, visual field and visual evoked potential evaluations; the imaging was repeated 1 year later. The results of the conventional Short Tau Inversion Recovery (STIR) sequence obtained using short time echo (STE-STIR: 22 msec) were compared with those of the long time echo sequence (LTE-STIR: 80 msec). The conventional STE-STIR sequence revealed lesions in 57.2% cases of acute ON and in 42.9% of the optic nerves affected by previous ON; the LTE-STIR sequence was diagnostic in 95.2% of acute ON cases and in 85% of patients with previous ON. The calculated length of the optic nerve lesions was significantly longer in the images obtained using the LTE-STIR sequence than in those obtained using conventional STE-STIR sequences.

Adult↗

Imaging the optic nerve in multiple sclerosis.

Although multiple sclerosis (MS) frequently involves the optic nerves, imaging this structure is not yet performed routinely in clinical practice. The recent improvement of magnetic resonance (MR) technology and the development of new MR strategies, capable of providing an, in vivo, overall assessment of MS pathology has allowed objective metrics to be obtained for monitoring disease evolution, essentially in the brain. However, despite this progress, the correlation between brain MR metrics of the disease and clinical disability are still disappointing. An objective and accurate estimate of the presence and extent of optic nerve involvement might help to overcome this clinical/MRI paradox. This review summarizes the main results obtained from the application of conventional and modern MR-based techniques for the evaluation of optic nerve damage in MS.

Atrophy↗

Three-dimensional optical tomographic imaging of breast in a human subject.

We present for the first time a full three-dimensional (3-D) reconstruction of absorption images of breast from continuous-wave (cw) measurements performed on a premenopausal woman. Our 3-D optical images clearly reveal a large primary tumor as well as a small secondary tumor in a separate location of the breast. The multiple tumors identified by our 3-D optical imaging have been confirmed by the subsequent biopsy examination of the breast. Quantitative information of the optical images obtained is provided in terms of the location, size, and absorption coefficient of the tumors.

Biopsy↗

Optical tomographic imaging of small animals.

Diffuse optical tomography is emerging as a viable new biomedical imaging modality. Using visible and near-infrared light this technique can probe the absorption and scattering properties of biological tissues. The main applications are currently in brain, breast, limb and joint imaging; however, optical tomographic imaging of small animals is attracting increasing attention. This interest is fuelled by recent advances in the transgenic manipulation of small animals that has led to many models of human disease. In addition, an ever increasing number of optically reactive biochemical markers has become available, which allow diseases to be detected at the molecular level long before macroscopic symptoms appear. The past three years have seen an array of novel technological developments that have led to the first optical tomographic studies of small animals in the areas of cerebral ischemia and cancer.

Animals↗

Task-based optimization and performance assessment in optical coherence imaging.

Optimization of an optical coherence imaging (OCI) system on the basis of task performance is a challenging undertaking. We present a mathematical framework based on task performance that uses statistical decision theory for the optimization and assessment of such a system. Specifically, we apply the framework to a relatively simple OCI system combined with a specimen model for a detection task and a resolution task. We consider three theoretical Gaussian sources of coherence lengths of 2, 20, and 40 microm. For each of these coherence lengths we establish a benchmark performance that specifies the smallest change in index of refraction that can be detected by the system. We also quantify the dependence of the resolution performance on the specimen model being imaged.

Algorithms↗

Signal degradation by multiple scattering in optical coherence tomography of dense tissue: a Monte Carlo study towards optical clearing of biotissues.

Multiple scattering is a major source that limits light penetration into biotissues, thereby preventing visualization of the deep microstructures for high-resolution optical imaging techniques. The optical clearing approach is a new adventure in biomedical optics for manipulating the optical properties of tissue; for example, the scattering coefficient and the degree of forward scattering of photons, by the use of the chemical administration method in order to improve the optical imaging depth, particularly for the recently developed optical coherence tomography (OCT). This paper investigates systematically how the multiple scattering affects signal attenuation and localization in general, and how the alterations of optical properties of tissue enhance the optical imaging depth and signal localization in particular, by the use of Monte Carlo simulations through the separate considerations of the least scattered photons (LSP) and multiple scattered photons (MSP). The LSP are those photons that contribute to the precise OCT signal, i.e. localization, and the MSP are those that degrade the OCT signal. It is shown that with either the reduction of the scattering coefficient or the increase of the degree of forward scattering, signal localization and imaging depth for OCT is enhanced. Whilst the increase of the anisotropic factor of the medium is more efficient in improving signal localization, it introduces more scattering events for the photons travelling within the tissue for both the LSP and MSP. It is also found that the OCT imaging resolution is almost reduced exponentially with the increase of the probing depth as opposed to the claimed system resolution. We demonstrate that optical clearing could be a useful tool to improve the imaging resolution when the light progressively penetrates the high scattering medium. Experimental results are also presented to show intuitively how multiple scattering affects OCT signal profiles by the use of intralipid solution and healthy human whole blood, representing moderately and highly scattering media respectively.

Anisotropy↗

Biomedical applications of fluorescence imaging in vivo.

Optical imaging can advance knowledge of cellular biology and disease at the molecular level in vitro and, more recently, in vivo. In vivo optical imaging has enabled real-time study to track cell movement, cell growth, and even some cell functions. Thus, it can be used in intact animals for disease detection, screening, diagnosis, drug development, and treatment evaluation. This review includes a brief introduction to fluorescence imaging, fluorescent probes, imaging devices, and in vivo applications in animal models. It also describes a quantitative fluorescence detection method with a reconstruction algorithm for determining the location of fluorophores in tissue and addresses future applications of in vivo fluorescence imaging.

Algorithms↗

Optic nerve diffusion measurement from diffusion-weighted imaging in optic neuritis.

BACKGROUND AND PURPOSE: Increases in apparent diffusion coefficient (ADC) from diffusion-weighted (DW) imaging are thought to be due to axonal disruption, and changes have been well documented in multiple sclerosis lesions. DW imaging of the optic nerves, however, presents many challenges. The goal of this study was to measure ADC in patients with optic neuritis by using zonal oblique multisection echoplanar imaging. METHODS: The optic nerves of eighteen patients who had experienced an attack of optic neuritis 1 year previously and 11 control subjects were imaged with the diffusion sequence (usable data were available from 16 patients and 10 control subjects). The orbital optic nerves were segmented by a blinded observer by using a computer-assisted threshold-based contouring technique, and the mean ADC was determined. RESULTS: The mean ADC from diseased optic nerves was 1324 x 10(-6) mm2/s, compared with 990 x 10(-6) mm2/s from healthy contralateral optic nerves (P = .005 versus diseased optic nerves) and 928 x 10(-6) mm2/s from control optic nerves (P = .006 versus diseased optic nerves and P = .40 versus healthy contralateral optic nerves). The diseased optic nerve ADC correlated with both visual (e.g., r(S) = 0.73; P = .001 for logMAR visual acuity) and electrophysiological parameters (e.g., r(S) = -0.57, P = .021 for visual evoked potential central field amplitude [VEP]). CONCLUSION: It has been possible to apply DW imaging in a patient population, and, in the chronic phase following optic neuritis, the correlation of mean ADC with the clinical and electrophysiological parameters suggests that the ADC is giving a surrogate measure of axonal disruption in the chronic, postinflammatory optic nerve lesion.

Adult↗

High-sensitivity CCD-based X-ray detector.

The detector is designed for imaging measurements requiring relatively high sensitivity and high spatial resolution. The detector can discriminate single X-ray photons, yet has the wide dynamic range ( approximately 10000:1) associated with integrating detectors. A GdO2S2 phosphor screen converts the incoming X-ray image into an optical image. The optical image is coupled (without demagnification) to the CCD image sensor using a fiber optic faceplate. The CCD (Philips Semiconductors) has an area of 4.9 x 8.6 cm with 4000 x 7000 12 microm pixels. A single 12 keV X-ray photon produces a signal of 100 e-. With 2 x 2 pixel binning, the total noise per 24 microm pixel in a 100 s image is approximately 30 e- the detective quantum efficiency is >0.6 at 1 X-ray photon per pixel, and the full image can be read out in <4 s. The spatial resolution is 50 microm. The CCD readout system is fully computer-controlled, allowing flexible operation in time-resolved experiments. The detector has been characterized using visible-light images, X-ray images and time-resolved muscle diffraction measurements.

Actin Cytoskeleton↗