Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compression Algorithms”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32Linked to original sources

Error-resilient video communications over CDMA networks with a bandwidth constraint.

We present an adaptive video transmission scheme for use in a code-division multiple-access network, which incorporates efficient bandwidth allocation among source coding, channel coding, and spreading under a fixed total bandwidth constraint. We derive the statistics of the received signal, as well as a theoretical bound on the packet drop rate at the receiver. Based on these results, a bandwidth allocation algorithm is proposed at the packet level, which incorporates the effects of both the changing channel conditions and the dynamics of the source content. Detailed simulations are done to evaluate the performance of the system, and the sensitivity of the system to estimation error is presented.

Algorithms↗

Branching competitive learning network: a novel self-creating model.

This paper presents a new self-creating model of a neural network in which a branching mechanism is incorporated with competitive learning. Unlike other self-creating models, the proposed scheme, called branching competitive learning (BCL), adopts a special node-splitting criterion, which is based mainly on the geometrical measurements of the movement of the synaptic vectors in the weight space. Compared with other self-creating and nonself-creating competitive learning models, the BCL network is more efficient to capture the spatial distribution of the input data and, therefore, tends to give better clustering or quantization results. We demonstrate the ability of the BCL model to appropriately estimate the cluster number in a data distribution, show its adaptability to nonstationary data inputs and, moreover, present a scheme leading to a multiresolution data clustering. Extensive experiments on vector quantization of image compression are given to illustrate the effectiveness of the BCL algorithm.

Artificial Intelligence↗

Reliability of surface electromyographic measurements from subjects with spinal cord injury during voluntary motor tasks.

In this study, the reliability of surface electromyographic data (root-mean-square) for volitional motor tasks drawn from a standardized protocol was assessed. For each motor task, 5 s epochs of data were analyzed with a new method to generate a measure called the voluntary response index (VRI). The VRI consists of two components, magnitude and similarity index (SI), that were separately analyzed for repeatability. We examined three repetitions of each of 10 volitional motor tasks in 69 subjects with spinal cord injury (American Spinal Injury Association [ASIA] Impairment Scale [AIS], classifications C and D: 34 AIS-C and 35 AIS-D) for short-term (within-day) reliability. In 6 of the 69 subjects (3 each, AIS-C and AIS-D), the entire study was repeated after 1 week and results were assessed for intermediate-term (1 week apart) reliability. The reliability of the method for voluntary motor tasks was assessed by intraclass correlation coefficient (ICC), analysis of variance, coefficient of variance, and Pearson's correlation. Good reliability was found for magnitude (ICC = 0.71-0.99, Pearson's r = 0.77-0.99) and for SI (ICC = 0.65-0.96, Pearson's r = 0.72-0.93) for three repeated tests (within-day). Significant difference was found for studies completed 1 week apart for magnitude (p = 0.02) but not for SI (p = 0.57). In addition, SI showed less variation than magnitude (p < 0.001). No significant difference of magnitude and SI between tasks was observed.

Algorithms↗

Knowledge and skill after brief ACLS training.

OBJECTIVES: To determine the knowledge level and skill base in nurse anesthetists before and after brief ACLS training, and again three months later. METHOD: Thirty nurse anesthetists were tested for knowledge and skill before ACLS training comprising 1-hr lecture and handout, and 1-hr simulation training. Concepts included ABCD, primary and secondary survey, management, medications, and algorithms for common problems. Skill practice comprised airway management, chest compression and practice with equipment. After the training, the nurse anesthetists were immediately tested and again three months later. RESULTS: Age of participants averaged 39.33 + or - 3.14 years and working experience 10.04 +/- 3.23 years. The knowledge and skill scores pre- vs post-training vs three-months-later was 50.32 +/- 15.24 vs 75.40 +/- 10.29 (p < 0.001) vs 60.48 +/- 11.80 (p < 0.001) and 65.00 + 16.07 vs 79.67 +/- 10.80 (p < 0.001) vs 75.67 +/- 14.53 (p < 0.001), respectively. The pre-training vs three-months-post-training skill scores was not statistically different (p = 0.255). CONCLUSION: After the briefACLS training knowledge and skills were significantly improved, but knowledge was not retained at the post-training test levels until the 3-month check, albeit skills had persisted. More frequent ACLS education is necessary.

Adult↗

Digital imaging and picture archiving and communication systems.

Great progress has been made in digital imaging of the chest. Most studies are dealing with computed radiography. Chest radiography in the intensive care unit may, in most cases, be performed using computed radiography. However, subtle pulmonary interstitial disease can be demonstrated less confidently using computed radiography. Significantly better detection of calcified lung nodules can be obtained by using simplified single-exposure dual-energy technique that uses storage phosphor. The wide latitude of computed radiography permits images of high quality in areas other than chest radiography. Encouraging results are presented especially in the diagnostic evaluation of scoliosis and other musculoskeletal abnormalities. An important technical innovation in digital radiography is an improved method for single-exposure dual-energy digital imaging using prefiltration with gadolinium, a cassette consisting of four photostimulable phosphor plates, spatially dependent scatter and beam hardening corrections, and noise reduction algorithm. Other groups tested algorithms for enhancement of digital images that allowed significant data compression. The implementation of picture archiving and communication systems (PACS) is inevitable; the question concerning PACS implementation is not why, but when. A comparison of the cost-effectiveness of PACS with conventional film archiving and communication systems shows that PACS should provide indirect savings when regarding the hidden costs of conventional systems. Much more experience will be needed before there is general agreement on the best design for the radiologist's workstation. Teleradiology should contribute to radiologic consultation for remote locations, because it improves the efficacy of management of patients in such locations.

Child↗

Lossy compression in nuclear medicine images.

The goal of image compression is to reduce the amount of data needed to represent images. In medical applications, it is not desirable to lose any information and thus lossless compression methods are often used. However, medical imaging systems have intrinsic noise associated to it. The application of a lossy technique, which acts as a low pass filter, reduces the amount of data at a higher rate without any noticeable loss in the information contained in the images. We have compressed images of nuclear medicine using the discrete cosine transform algorithm. The decompressed images were considered reliable for visual inspection. Furthermore, a parameter was computed from these images and no discernible change was found from the results obtained using the original uncompressed images.

Algorithms↗

A digital filterbank hearing aid: predicting user preference and performance for two signal processing algorithms.

OBJECTIVE: In a series of experiments with a wearable binaural digital hearing aid, two hearing aid processing algorithms were compared. Both algorithms provided individual frequency shaping via a seven-band filterbank with compression limiting in the high-frequency channel. They differed in the processing of the low-frequency channel, using dynamic range compression for one (DynEar) and linear processing with compression limiting for the other (LinEar). In a pilot field test we found that LinEar/ DynEar preference based on use time could be predicted from auditory dynamic range data. For the subjects who preferred DynEar, the mean dynamic range was broader for low and mid frequencies and narrower for high frequencies, as compared with the LinEar preference subjects. These groupings were tested as predictors of user preference and performance in a main field test. DESIGN: The main study included 26 hearing aid users with symmetrical sensorineural losses. The algorithms were compared in a one-mo-long blind field test. A data logger function was included for objective recording of the total time each algorithm was used and how the volume controls were used. The preference was based on the time used for each algorithm and on subjective statements. Threshold signal-to-noise ratio (S/N-threshold) for speech was tested, and sound quality ratings were obtained through a questionnaire. We also tested the S/N-thresholds for the subjects' conventional (own) aids. RESULTS: The preference was correctly predicted by the dynamic range data on 12 out of 15 new cases. S/N-thresholds were lower for the preferred fittings compared with the nonpreferred fittings and with the subjects' own aids. In the questionnaire the preferred fittings were rated significantly higher in terms of overall impression and clearness. Because of the systematic way the DynEar-preference subjects adjusted the high-frequency DynEar gain, we speculate that upward spread of masking may have been a factor in preference and performance. Additionally, LinEar-preference subjects' preference and performance might have been influenced by excessive compression ratios with the DynEar processing in these cases. CONCLUSIONS: 1. Preference for DynEar versus LinEar depends on the auditory dynamic range. 2. S/N-thresholds for speech were better for the preferred fittings, which also were rated higher in terms of overall impression of sound quality and clearness.

Adult↗

Enhanced real-time ECG coder for packetized telecardiology applications.

A new real-time compression method for electrocardiogram (ECG) signals has been developed based on the wavelet transform approach. The method is specifically adaptable for packetized telecardiology applications. The signal is segmented into beats and a beat template is subtracted from them, producing a residual signal. Beat templates and residual signals are coded with a wavelet expansion. Compression is achieved by selecting a subset of wavelet coefficients. The number of selected coefficients depends on a threshold which has different definitions depending on the operational mode of the coder. Compression performance has been tested using a subset of ECG records from MIT-BIH Arrhythmia database. This method has been designed for real-time packetized telecardiology scenarios both in wired and wireless environments.

Algorithms↗

Compression of surface EMG signals with algebraic code excited linear prediction.

Despite the interest in long timescale recordings of surface electromyographic (EMG) signals, only a few studies have focused on EMG compression. In this paper we investigate a lossy coding technique for surface EMG signals that is based on the algebraic code excited linear prediction (ACELP) paradigm, widely used for speech signal coding. The algorithm was adapted to the EMG characteristics and tested on both simulated and experimental signals. The coding parameters selected led to a compression ratio of 87.3%. For simulated signals, the mean square error in signal reconstruction and the percentage error in average rectified value after compression were 11.2% and 4.90%, respectively. For experimental signals, they were 6.74% and 3.11%. The mean power spectral frequency and third-order power spectral moment were estimated with relative errors smaller than 1.23% and 8.50% for simulated signals, and 3.74% and 5.95% for experimental signals. It was concluded that the proposed coding scheme could be effectively used for high rate and low distortion compression of surface EMG signals. Moreover, the method is characterized by moderate complexity (approximately 20 million instructions/s) and an algorithmic delay smaller than 160 samples (approximately 160ms).

Adult↗

A single mediaprocessor-based programmable ultrasound system.

We have developed a programmable ultrasound imaging system using a single commercially available mediaprocessor. We have efficiently mapped all of the necessary B-mode processing algorithms on the underlying processor architecture, including envelope detection, dynamic range compression, lateral and axial filtering, persistence processing, and scan conversion. Our system can handle varying specifications ranging from 128 vectors and 512 samples per vector to more than 256 vectors and 1024 samples per vector. For an image size of 330 vectors and 512 samples per vector, it can process 30 frames per second using a 300-MHz MAP-CA mediaprocessor from Hitachi/Equator Technologies. This programmable ultrasound machine will not only offer significant advantages in terms of low cost, portability, scalability, and reduced development time, but also provide a flexible platform for developing and deploying new clinical applications to aid the clinicians and improve the quality of healthcare to patients.

Algorithms↗

Compressibility of floating pellets with verapamil hydrochloride coated with dispersion Kollicoat SR 30 D.

The purpose of this study was to work out a method of compression of floating pellets with verapamil hydrochloride (VH) in a dose of 40 mg. It was assumed that this form should reside in the stomach floating for several hours and gradually release the drug in a controlled way. Compression of pellets into tablets, being a modern technological process, is much more perfect than enclosing them in a hard gelatin capsule. Kollicoat SR 30 D was selected for coating. In experiments three plasticizers were examined-propylene glycol, triethyl citrate and dibuthyl sebecate (all at concentration of 10%). It was found that VH release from pellets coated by the films of the same thickness (70 microm), however, containing plasticizers is considerably different. Pellets were prepared by wet granulation of powder mixture, spheronization of the granulated mass and coating of the cores with a sustained release film. Two kinds of cellulose, microcrystalline and powdered, and sodium hydrocarbonate were the main components of pellet core. Proper pellet coating film thickness, ensuring obtaining desirable VH release profile and flotation effect, was defined. X compositions of tablets with pellets were examined in order to obtain formulation, from which VH release would mostly approximate pellets before compressing. The best formulation was evaluated taking into account the effect of compression force an tablet hardness and friability, and pellet agglomeration and flotation. Tablet cross-section photographs were taken confirming necessary coating film thickness preventing their deformation caused by compressing into tablets.

Algorithms↗

Blind MPEG-2 video watermarking robust against geometric attacks: a set of approaches in DCT domain.

A set of robust MPEG-2 video watermarking techniques is proposed, focusing on commonly used typical geometric processing for bit-rate reduction, cropping, removal of any rows, arbitrary-ratio downscaling, and frame dropping. Both the embedding and the extraction of watermarks are done in the compressed domain, so the computational cost is low. Moreover, the watermark extraction is blind, i.e., no original unwatermarked MPEG-2 video is needed for watermark extraction. The presented technique is applicable not only to MPEG-2 video, but also to other DCT-based coding videos. Selected experimental results validate our techniques.

Algorithms↗

Shear properties of the temporomandibular joint disc in relation to compressive and shear strain.

Shear stress can result in fatigue, damage, and irreversible deformation of the temporomandibular joint disc. Insight into the dynamic shear properties of the disc may give insight into the mechanism inducing tissue failure due to shear. We tested the hypothesis that the dynamic shear properties of the disc depend on the amount of shear and compressive strain. Twenty-four porcine discs were used for dynamic shear tests. The specimens were clamped between the plates of a loading apparatus under compressive strains of 5%, 10%, and 15%. Dynamic shear was applied to the specimen by a sinusoidal strain of, respectively, 0.5%, 1.0%, and 1.5%. Both the dynamic elasticity and viscosity were proportional to compressive strain and inversely proportional to shear strain. These shear characteristics suggest a significant role of compressive and shear strain on the internal friction of the disc.

Algorithms↗

ECG data compression using adaptive Fourier coefficients estimation.

In this article, a new ECG data compression technique is proposed. The method relies on modelling quasi-periodic ECG signals as a dynamic Fourier series. Fourier coefficients are continuously estimated using the adaptive least-mean-square algorithm. Results from simulated normal and pathological ECGs are presented and discussed. A comparison with other compression techniques is also discussed.

Electrocardiography, Ambulatory↗

Modeling of a roller-compaction process using neural networks and genetic algorithms.

In this study, roller-compaction of acetaminophene was studied to model the effect of binder type (hydroxypropyl methyl cellulose (HPMC), polyethylene glycol (PEG), Carbopol), binder concentration (5, 10 and 20%), number of roller-compaction passes (one or two), and extragranular microcrystalline cellulose addition on the properties of compressed tablets. Forty-two batches resulted from the experimental design. The artificial neural network methodology (ANN) along with genetic algorithms were used for data analysis and optimization. ANN and genetic models provided R2 values between 0.3593 and 0.9991 for measured responses. When a set of validation experiments was analyzed, genetic algorithm predictions of tablet characteristics were much better than the ANN. Optimization based on genetic algorithm showed that using HPMC at 20%, with two roller-compaction passes would produce mechanically acceptable acetaminophene tablets. PEG and carbopol would also produce acceptable tablets perhaps more suitable for sustained release applications. Using PEG as a binder had the additional advantage of not requiring an external lubricant during tablet manufacturing.

Acetaminophen↗

JPEG compression for PACS.

In the medical field, especially in diagnostic radiology, there still remains controversy over how and whether or not to compress X-ray images for storage and transmission. The joint Photographic Expert Group (JPEG) standard which has recently been agreed upon is the very attractive technique to archive and to transport images in medical fields. This technique is based on 'lossy' compression of images, which can handle not only X-ray images but also full-colored images, and is suitable for introduction into picture archiving and communicating systems (PACS). The images can be handled after compression as quite small clusters of data. For example, a single 2000 x 2000 x 12 bits chest X-ray image which is an 8 Mbyte image compressed at a 10:1 ratio could retain virtually all the visible quality of the original version, and would take 100 s to transmit at 64 kbits/s using the Integrated Services Digital Network (ISDN, 800 kbytes compressed file, 8 kbytes/s transmission theoretically). An important factor in the design of this technique is that this format relies on no specific hardware or software if using JFIF (JPEG File interchange Format). Soon this algorithm will be able to run on any workstation or on any PC in the world. Highly compressed images may be unsuitable for diagnostic purposes. However, they may be sufficient for reference images which will be needed in clinical fields.

Algorithms↗

[Guidelines for advanced cardiopulmonary resuscitation of adult patients. European Resuscitation Council].

In this paper 16 experts from ten different countries present an abridged version of the 1998 European Resuscitation Council guidelines for advanced adult life support. There are few changes from the 1992 version, and they are mainly made for educational reasons. There is thus no convincing new scientific evidence that warrants changes in the guidelines. While there previously were three separate algorithms for ventricular fibrillation/ventricular tachycardia, asystole and electromechanical dissociation, there is now only one algorithm. The ventilation volume has been reduced to 400-600 ml, and the chest compression frequency has been increased to 100 min-1. For other rhythms than ventricular fibrillation/ventricular tachycardia, ventilation and chest compressions should now be performed for three minute periods, not one minute as used to be the rule. One minute is still the correct period for ventricular fibrillation/ventricular tachycardia.

Adult↗