Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32Linked to original sources

Assessment of the components of observed chronic pain behavior: the Checklist for Interpersonal Pain Behavior (CHIP).

This article describes the development of the Checklist for Interpersonal Pain Behavior (CHIP), an observation scale which assesses overt pain behavior. The study is an extension of an earlier study in which the dimensions and components of observed chronic pain behavior were examined. A broad definition of pain behavior is chosen (interpersonal pain behavior), namely the interaction between the pain patient and his/her direct environment. The list of pain behaviors, taken from the earlier study, has been transformed into a 78-item global rating scale to be used by nurses to quantify observed pain behavior in a clinical setting. Six studies examine the factor structure and the psychometric properties of this behavioral observation method. In the first study, 6 internally reliable factors are derived using factor analytic techniques from a sample of 152 chronic pain patients. They are labeled as: 'distorted mobility,' 'verbal complaints,' 'non-verbal complaints,' 'nervousness,' 'depression' and 'day sleeping.' Internal consistency of all factors, except 'day sleeping' was excellent. The following studies show that the CHIP is sufficiently reliable and valid. After a discussion on the advantages of this observation scale, the conclusion seems justified that the CHIP is a useful tool in pain assessment that can easily be used by nurses.

Adult↗

Detection of bacteriophage infection and prophage induction in bacterial cultures by means of electric DNA chips.

Infections of bacterial cultures by bacteriophages are common and serious problems in many biotechnological laboratories and factories. A method for specific, quantitative, and quick detection of phage contamination, based on the use of electric DNA chip is described here. Different phages of Escherichia coli and Bacillus subtilis were analyzed. Phage DNA was isolated from bacterial culture samples and detected by combination of bead-based sandwich hybridization with enzyme-labeled probes and detection of the enzymatic product using silicon chips. The assay resulted in specific signals from all four tested phages without significant background. Although high sensitivity was achieved in 4h assay time, a useful level of sensitivity (10(7)-10(8) phages) is achievable within 25 min. A multiplex DNA chip technique involving a mixture of probes allows for detection of various types of phages in one sample. These analyses confirmed the specificity of the assay.

Bacillus subtilis↗

The E3 ubiquitin ligase CHIP binds the androgen receptor in a phosphorylation-dependent manner.

In Eukarya, the 26S proteasome is primarily responsible for intracellular protein degradation. To be degraded, proteins must be ubiquitinated. The latter requires a multi-enzyme cascade consisting of an E1, an E2, and an E3 enzyme. While there is only a single E1 and a few E2s, there are many different E3s that target substrates by recognizing specific sequence motifs, known as degrons. Here, we have used the peptide array technology to identify binding motifs in the human androgen receptor (AR), which are recognized by the Carboxyl-terminus of Hsc70-Interacting Protein (CHIP), a U-box E3 and Hsp70/Hsp90 co-chaperone. We show that CHIP recognizes AR in a highly specific, phosphorylation- and sequence-dependent manner, and propose that this interaction could provide a mechanism that regulates the degradation of CHIP substrates.

Amino Acid Motifs↗

Development of a protein microarray using sequence-specific DNA binding domain on DNA chip surface.

A protein microarray based on DNA microarray platform was developed to identify protein-protein interactions in vitro. The conventional DNA chip surface by 156-bp PCR product was prepared for a substrate of protein microarray. High-affinity sequence-specific DNA binding domain, GAL4 DNA binding domain, was introduced to the protein microarray as fusion partner of a target model protein, enhanced green fluorescent protein. The target protein was oriented immobilized directly on the DNA chip surface. Finally, monoclonal antibody of the target protein was used to identify the immobilized protein on the surface. This study shows that the conventional DNA chip can be used to make a protein microarray directly, and this novel protein microarray can be applicable as a tool for identifying protein-protein interactions.

Base Sequence↗

Spotting and validation of a genome wide oligonucleotide chip with duplicate measurement of each gene.

The quality of DNA microarray based gene expression data relies on the reproducibility of several steps in a microarray experiment. We have developed a spotted genome wide microarray chip with oligonucleotides printed in duplicate in order to minimise undesirable biases, thereby optimising detection of true differential expression. The validation study design consisted of an assessment of the microarray chip performance using the MessageAmp and FairPlay labelling kits. Intraclass correlation coefficient (ICC) was used to demonstrate that MessageAmp was significantly more reproducible than FairPlay. Further examinations with MessageAmp revealed the applicability of the system. The linear range of the chips was three orders of magnitude, the precision was high, as 95% of measurements deviated less than 1.24-fold from the expected value, and the coefficient of variation for relative expression was 13.6%. Relative quantitation was more reproducible than absolute quantitation and substantial reduction of variance was attained with duplicate spotting. An analysis of variance (ANOVA) demonstrated no significant day-to-day variation.

Gene Expression Profiling↗

Micro pulsed radio-frequency electroporation chips.

Electroporation (EP) is one of the most important physical methods in biotechnology, which employs electrical pulses to transiently permeabilize cell membranes. In this study, a new micro pulsed radio-frequency electroporation cell (microPREP) chip was fabricated using a lift-off technique and SU-8 photolithography. The biological tests were carried out using three different plant protoplasts (cabbage, spinach and oil rape) on the micro EP chip and a pulsed RF electric field was applied to the microchip. The variations of fluorescent intensity and cell viability as functions of the electric pulse amplitude and duration time during the electroporation process were studied in detail at the single-cell level. Using such chip design and test method, one can easily optimize the efficiency and cell viability. Also, a large amount of statistical data can be quickly obtained. Finally, results of this parametric study were presented in the "phase diagram", from which the critical electric field for inducing single-cell electroporation under different conditions can be clearly determined.

Brassica↗

Application of on-chip cell cultures for the detection of allergic response.

In this report, the development of a microfluidic cell chip for monitoring allergic response is described. A rat basophilic leukemia cell line (RBL-2H3), a tumor analog of rat mucosal mast cells, has been used as a model to observe its allergic response upon antigen stimulus. The cells were cultivated on a poly(dimethylsiloxane) (PDMS) chip, the surface of which was modified by several methods. The PDMS chip, which comprised a cell cultivation chamber and microfluidic channels, was fabricated by conventional molding methods. In order to detect the allergic response, a fluorescent dye, quinacrine, was introduced inside the cell compartment that included histamine. The cells were stimulated with dinitrophenylated bovine serum albumin (DNP-BSA) after incubation with anti-DNP IgE. When exocytosis events occurred, the microfluidic system detected the fluorescent signal of quinacrine, which was released from RBL-2H3 cells by using a photomultiplier tube (PMT) fitted onto a microscope.

Animals↗

Oligonucleotide ligation assay-based DNA chip for multiplex detection of single nucleotide polymorphism.

An oligonucleotide ligation assay-based DNA chip has been developed to detect single nucleotide polymorphism. Synthesized nonamers, complementary to the flanking sequences of the mutation sites in target DNA, were immobilized onto glass slides through disulfide bonds on their 5' terminus. Allele-specific pentamers annealed adjacent to the nonamers on the complementary target DNA, containing 5'-phosphate groups and biotin labeled 3'-ends, were mixed with the target DNA in tube. Ligation reactions between nonamers and pentamers were carried out on chips in the presence of T4 DNA ligase. Ligation products were directly visualized on chips through enzyme-linked assay. The effect of G:T mismatch at different positions of pentamers on the ligation were evaluated. The results showed that any mismatch between pentamer and the target DNA could lead to the decrease of ligation, which can be detected easily. The established approach was further used for multiplex detection of mutations in rpoB gene of rifampin-resistant Mycobacterium tuberculosis clinical isolates.

DNA↗

The fabrication of protein chip based on surface plasmon resonance for detection of pathogens.

Protein chip based on surface plasmon resonance (SPR) was developed for detection of pathogens existing in contaminated environment, such as Escherichia coli O157:H7, Salmonella typhimurium, Legionella pneumophila, and Yersinia enterocolitica. Protein G was immobilized to endow the orientation of antibody molecules on the SPR surface. The pathogen binding of the protein chip was investigated by SPR spectroscopy. Consequently, it was found that the four kinds of pathogen could be selectively detected by using SPR-based protein chip.

Bacteria↗

Oligonucleotide chip for the diagnosis of HNF-1 alpha mutations.

Mutations in HNF-1 alpha cause maturity-onset diabetes of the young (MODY) type 3, which is the most prevalent MODY subtype in most countries. In the present study, we investigated an oligonucleotide microchip for the detection of the known HNF-1 alpha mutations. We first optimized the coupling chemistries for covalent immobilization of allele-specific oligonucleotides on aldehyde (CHO)- and thiocyanate (NCS)-activated glass slides and compared their hybridization efficiencies. CHO-glass was found to provide a more favorable environment for hybridization than NCS-glass, whereas the binding capacity of NCS-glass for amine-activated oligonucleotide was much greater than with CHO-glass. We also investigated the effects of the length of the capture probes on the hybridized signals. To determine the presence of HNF-1 alpha mutations in a human sample, we prepared an oligonucleotide chip from selected mutation sites of exon2 from HNF-1 alpha. Cy3-labeled RNA target probes were obtained by in vitro transcription of promoter-tagged PCR products from a wild-type blood sample and subsequent fragmentation. Hybridization of the chip with the RNA target probes successfully identified all of the genotypes for the tested sites. This work demonstrates that oligonucleotide chip-based analysis is a good candidate for routine clinical testing for HNF-1 alpha mutations.

DNA Mutational Analysis↗

Electrochemical mutagen screening using microbial chip.

Electrochemical microbial chip for mutagen screening were microfabricated and characterized by scanning electrochemical microscopy (SECM). Salmonella typhimurium TA1535 with a plasmid pSK1002 carrying a umuC'-'lacZ fusion gene was used for the whole cell mutagen sensor. The TA1535/pSK1002 cells were exposed to mutagen solutions containing 2-(2-furyl)-3-(5-nitro-2-furyl)acrylamido (AF-2), mitomycin C (MMC) or 2-aminoanthracene (2-AA) and embedded in a microcavity (5nl) on a glass substrate using collagen gel. The beta-galactosidase expression on the microbial chip was electrochemically monitored using p-aminophenyl-beta-d-galactopyranoside (PAPG) as the enzymatic substrate. This system has several advantages compared with the conventional umu test: drastic reduction of the sample volume, less time-consuming for beta-galactosidase detection (free from substrate reaction time) and lower detection limit for the three mutagens (AF-2, MMC, 2-AA). Finally, a multi-sample assay was carried out using the microbial array chip with four microcavities.

Biological Assay↗

Clinical evaluation of micro-scale chip-based PCR system for rapid detection of hepatitis B virus.

The polymerase chain reaction (PCR) is widely used to amplify a small amount of DNA in samples for genetic analysis. Rapid and accurate amplification is prerequisite for broad applications including molecular diagnostics of diseases, food safety, and biological warfare tests. We have developed a rapid real-time micro-scale chip-based PCR system, which consists of six individual thermal cycling modules capable of independent control of PCR protocols. The PCR volume is 1 microl and it takes less than 20 min to complete 40 thermal cycles. To test utility of a chip-based PCR system as a molecular diagnostic device, we have conducted the first large-scale clinical evaluation study. Three independent clinical evaluation studies (n = 563) for screening the hepatitis B virus (HBV) infection, the most popular social epidemic disease in Asia, showed an excellent sensitivity, e.g. 94%, and specificity, e.g. 93%, demonstrating micro-scale chip-based PCR can be applied in molecular diagnostics.

DNA, Viral↗

SU-8 based continuous-flow RT-PCR bio-chips under high-precision temperature control.

Being beneficial from dramatic progress in bio-chemical and micro-electro-mechanical technologies, DNA manipulation devices can be miniaturized to expedite amplification processing for virus detection. Polymerase chain reaction (PCR) and reverse transcription polymerase chain reaction (RT-PCR) are two typical examples of them. In this report, a micro-RT-PCR (microRT-PCR) chip is designed to quantitatively detect tumor viruses. Test sample reservoirs, RT-PCR meanders, and capillary electrophoresis are integrated on a SU-8 based monolithic chip. A high-precision temperature control module is well developed by embedding signal amplification circuits and an Intel 8051 microprocessor. The integrated system exhibits high efficacy for heat transfer, exemption of fluid flow clogging and superior sensitivity to precisely control the required reaction temperatures in all heated zones of microRT-PCR unit. Intensive simulations and experiments are presented to verify the validity of the fabricated bio-chip.

Biosensing Techniques↗

Nanocrystalline silicon-based oligonucleotide chips.

A novel oligonucleotide array sensor has been developed with nanocrystalline Si (ncSi) substrates. The ncSi was prepared by electrochemical etching technique. Our study indicated that both the binding capacity and the hybridization efficiency are dependent upon the particle size of ncSi. In contrary, the chips developed with Si substrates exhibit the lower binding capacity and hybridization efficiency. The improved performances of the sensor chips are attributed to the large specific surface area of ncSi compared to the existing conventional techniques. The sensor chips with the ncSi substrate of 13 nm-sized particle can be regenerated and reused for at least 12 times. The oligonucleotide array sensor also shows high stability, which can bear relatively the stringent conditions (e.g. 80 degrees C, 75% of relative humidity and 3.6 klx of irradiation).

Nanoparticles↗

Micro hole-based cell chip with impedance spectroscopy.

Electric fields can be used for the characterisation and manipulation of single biological cells. One approach to avoid the effect of electrode polarisation is to position cells on micro holes and to apply the electrical fields via the micro holes. For a correct characterisation and optimal manipulation, the electrical properties of the micro hole/cell interface must be understood. In this article, the electrical characteristics of a micro hole-based cell chip were investigated. By FEM simulation, it was estimated that the impedance measurement with micro hole-based chip is most dependent on the cell adhesion/spread rather than the intra-cellular space (contribution of intra-cellular space to the total impedance: 0.07% at 1 kHz, 0.3% at 1 MHz). The effective frequency range in which the impedance related with cell state on the hole considerably influences total measured impedance was below several kiloHertz. From the experiments, it was shown that the impedance of cell cultured on the hole at the low frequency range is increased during the increase of cultivation period, but is sensitively decreased after applying only several nanolitres of culture medium including 5% dimethlysulfoxide. This micro hole-based chip has a potential for monitoring the cell growth and the membrane integrity of even single cell without any labelling.

Biosensing Techniques↗

Amplification of fluorescence with packed beads to enhance the sensitivity of miniaturized detection in microfluidic chip.

This paper reports the pre-concentration of C-reactive protein (CRP) antigen with packed beads in a microfluidic chamber to enhance the sensitivity of the miniaturized fluorescence detection system for portable point-of-care testing devices. Although integrated optical systems in microfluidic chips have been demonstrated by many groups to replace bulky optical systems, the problem of low sensitivity is a hurdle for on-site clinical applications. Hence we integrated the pre-concentration module with miniaturized detection in microfluidic chips (MDMC) to improve analytical sensitivity. Cheap silicon-based photodiodes with optical filter were packaged in PDMS microfluidic chips and beads were packed by a frit structure for pre-concentration. The beads were coated with CRP antibodies to capture antigens and the concentrated antigens were eluted by an acid buffer. The pre-concentration amplified the fluorescence intensity by about 20-fold and the fluorescence signal was linearly proportional to the concentration of antigens. Then the CRP antigen was analyzed by competitive immunoassay with an MDMC. The experimental result demonstrated that the analytical sensitivity was enhanced up to 1.4 nM owing to the higher signal-to-noise ratio. The amplification of fluorescence by pre-concentration of bead-based immunoassay is expected to be one of the methods for portable fluorescence detection system.

Animals↗

Existing and emerging detection technologies for DNA (Deoxyribonucleic Acid) finger printing, sequencing, bio- and analytical chips: a multidisciplinary development unifying molecular biology, chemical and electronics engineering.

The current status and research trends of detection techniques for DNA-based analysis such as DNA finger printing, sequencing, biochips and allied fields are examined. An overview of main detectors is presented vis-à-vis these DNA operations. The biochip method is explained, the role of micro- and nanoelectronic technologies in biochip realization is highlighted, various optical and electrical detection principles employed in biochips are indicated, and the operational mechanisms of these detection devices are described. Although a diversity of biochips for diagnostic and therapeutic applications has been demonstrated in research laboratories worldwide, only some of these chips have entered the clinical market, and more chips are awaiting commercialization. The necessity of tagging is eliminated in refractive-index change based devices, but the basic flaw of indirect nature of most detection methodologies can only be overcome by generic and/or reagentless DNA sensors such as the conductance-based approach and the DNA-single electron transistor (DNA-SET) structure. Devices of the electrical detection-based category are expected to pave the pathway for the next-generation DNA chips. The review provides a comprehensive coverage of the detection technologies for DNA finger printing, sequencing and related techniques, encompassing a variety of methods from the primitive art to the state-of-the-art scenario as well as promising methods for the future.

Chemical Engineering↗

Facile synthesis of metal-chelating peptides on chip for protein array.

A unique peptide sequence of HGGHHG screening from a combinatorial synthetic peptide library showed a good chelating ability to bind a transition metal on a chip better than hexa-His peptide. It was directly conjugated with a His-Tagged proteins onto a chip in a mild aqueous solution and can be used this chip as a high throughput technique for protein array in order to detect and purify the His-Tagged proteins.

Chelating Agents↗