Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Thermometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31Linked to original sources

[External and intracavitary thermometry and the temperature sensitivity of the bladder in children].

The authors have determined specification indices of the intracavitary temperature of the urinary bladder in children of different age, which are compared with data of "reflected" temperature from the urinary bladder onto the abdominal wall which allows objective determination and control in dynamics of the course of the inflammatory process in the urinary bladder. The thermocontrast "cold" and "hyperthermic" cystotonometry are new methods of investigation allowing to objectively determine the state of the cold and warm receptors of the urinary bladder, to detect latent neurogenic disturbances of the urinary bladder and to prognose the effectiveness of treatment of hypermotor disturbances of functions of the urinary bladder.

Adolescent↗

Reliability of infra-red tympanic thermometry (ITT).

BACKGROUND: The ability to take a patient's temperature quickly, easily, and accurately is desirable in a variety of situations. However, in order to have confidence in the values obtained, it is important to quantify the reliability of the measurement. PURPOSE: The purpose of this study, therefore, was to determine the reliability of temperature measurements obtained by infra-red tympanic membrane thermometers. METHOD: This study examined intra-tester, inter-tester and inter-instrument reliability using two commercially available tympanic membrane thermometers. Forty-four college students (mean age 20.2 +/- 3.6 yr) had their tympanic membrane temperature taken by two investigators, each using two different instruments (ThermoScan Pro-1 and FirstTemp Genius). RESULTS: The results indicated a statistically significant difference between testers for each instrument. Similarly, there was a significant statistical difference between instruments within each tester. Correlations were moderately high (r = 0.66-0.88) between testers for each instrument, whereas correlations within instruments varied considerably between testers (r = 0.35-0.78). The intra-tester reliability was good for both testers using both instruments with all coefficients of variation (CV) less than 2%. Statistically significant differences were found between testers for each instrument and between instruments for each tester. A 2 x 2 ANOVA revealed a significant main effect for Tester and a significant Tester x Instrument interaction. CONCLUSION: We conclude that individual investigators are able to obtain reliable temperature measures when using either the FirstTemp Genius or ThermoScan Pro-1 instruments under resting laboratory conditions. However, inter-tester and inter-instrument reliability should be considered when collecting or comparing data.

Adolescent↗

Monitoring healing of acute Charcot's arthropathy with infrared dermal thermometry.

The purpose of this study was to describe the use of skin temperature assessment in diabetics with acute Charcot's arthropathy to monitor resolution of inflammation longitudinally throughout the course of treatment and to predict development of neuropathic ulcers. Thirty-nine diabetic subjects presenting with acute Charcot's arthropathy received thermometric monitoring throughout their treatment course. Subjects were treated with a standard protocol involving total contact casting, removable cast walkers, and progression to therapeutic shoes. There was a steady decrease in temperatures during the casting regimen. After temperature gradients normalized, subjects were progressed to custom therapeutic shoe gear and insoles and were followed for a mean 22.6 +/- 7.1 months. Following quiescence, 8% returned during the follow-up period with a new-onset neuropathic ulceration. Temperature gradients during taken the visit prior to ulceration were significantly higher in this group than for the rest of the population. Elevated temperatures were strongly correlated with the location of arthropathy. Temperatures decreased in a predictable manner as acute arthropathy resolved. Additionally, increased temperature gradients may be predictive of future ulceration.

Acute Disease↗

Comparison of intra-luminal versus intra-tumoural temperature measurements in patients with locally advanced prostate cancer treated with the coaxial TEM system: report of a feasibility study.

A study was performed on regional hyperthermia for patients with locally advanced prostate carcinoma. The primary objective was to analyse the thermometry data with an emphasis on the possibility of replacing invasive thermometry by tumour-related intra-luminal thermometry. Fourteen patients were treated with a combination of conformal external beam radiotherapy (70 Gy) and hyperthermia. Hyperthermia was delivered using the Coaxial TEM system, one treatment per week, to a total of five treatments. Thermometry was performed in bladder, urethra, rectum and esophagus. Invasive thermometry in the prostate was carried out during one or two treatments for each patient by placing transperineally a central and a peripheral catheter. Heterogeneous temperature distributions were measured in the prostate. The mean average invasive temperature range was 1.1 degrees C. Due to the temperature heterogeneity and a limited number of thermometry sensors (mean 7, range 2-13), large variability between treatments and patients existed regarding achieved temperatures and dose. The mean invasive T90 was 40.2 +/- 0.6 degrees C and T50 was 40.8 +/- 0.6 degrees C. The mean Cum min T90>40.5 degrees C per treatment was 22 (range 0-50). Importantly, intra-luminal temperatures did not reliably predict invasively measured temperatures. Invasive thermometry, therefore, remains compulsory to calculate a thermal dose for an individual patient. Changes in temperature during treatment, measured by the urethral sensors, corresponded well with changes in temperature measured by the individual invasive sensors. Similar comparison of rectal temperature changes with intra-prostatic temperature changes was not as predictive. The similarity in temperature changes between the urethral and interstial sites, suggests that urethral temperatures are sufficient for treatment optimization. The SAR profile did not correspond with the temperature profile indicating heterogeneous perfusion. Although regional hyperthermia in combination with external beam radiotherapy for locally advanced prostate carcinoma is clinically feasible, the question on the importance of invasive thermometry remains.

Aged↗

[Infrared temperature measurement in the ear canal with the DIATEK 9000 Instatemp and the DIATEK 9000 Thermoguide. Comparison with methods of temperature measurement in other body parts].

UNLABELLED: Temperature of the tympanic membrane is recommended as a "gold standard" of core-temperature recording. However, use of temperature probes in the auditory canal may lead to damage of tympanic membrane. Temperature measurement in the auditory canal with infrared thermometry does not pose this risk. Furthermore it is easy to perform and not very time-consuming. For this reason infrared thermometry of the auditory canal is becoming increasingly popular in clinical practice. We evaluated two infrared thermometers-the Diatek 9000 Thermoguide and the Diatek 9000 Instatemp-regarding factors influencing agreement with conventional tympanic temperature measurement and other core-temperature recording sites. In addition, we systematically evaluated user dependent factors that influence the agreement with the tympanic temperature. MATERIALS AND METHODS: In 20 volunteers we evaluated the influence of three factors: duration of the devices in the auditory canal before taking temperature (0 or 5 s), interval between two following recordings (30, 60, 90, 120, 180 s) and positioning of the grip relative to the auditory-canal axis (0, 60, 180 and 270 degrees). Agreement with tympanic contact probes (Mon-a-therm tympanic) in the contralateral ear was investigated in 100 postoperative patients. Comparative readings with rectal (YSI series 400) and esophageal (Mon-a-therm esophageal stethoscope with temperature sensor) probes were done in 100 patients in the ICU. The method of Bland and Altman was taken for comparison. RESULTS: Shortening of the interval between two consecutive readings led to increasing differences between the two measurements with the second reading decreasing. A similar effect was seen when positioning the infrared thermometers in the auditory canal before taking temperatures: after 5 s the recorded temperatures were significantly lower than temperature recordings taken immediately. Rotation of the devices out of the telephone handle position led to increasing lack of agreement between infrared thermometry and contact probes. Mean differences between infrared thermometry (Instatemp and Thermoguide, CAL-Mode) and tympanic probes were -0.41 +/- 0.67 degree C (2 SD) and -0.43 +/- 0.70 degree C, respectively. Mean differences between the Thermoquide (Rectal-Mode) and rectal probe were -0.19 +/- 0.72 degree C, and between the Thermoguide (Core Mode) and esophageal probe -0.13 +/- 0.74 degree C. DISCUSSION: Although easy to use, infrared thermometry requires careful handling. To obtain optimal recordings, the time between two consecutive readings should not be less than two min. Recordings should be taken immediately after positioning the devices in the auditory canal. Best results are obtained in the 60 degrees position with the grip of the devices following the ramus mandibulae (telephone handle position). The lower readings of infrared thermometry compared with tympanic contact probes indicate that the readings obtained represent the temperature of the auditory canal rather than of the tympanic membrane itself. To compensate for underestimation of core temperature by infrared thermometry, the results obtained are corrected and transferred into core-equivalent temperatures. This data correction reduces mean differences between infrared recordings and traditional core-temperature monitoring, but leaves limits of agreement between the two methods uninfluenced.

Body Temperature↗

Accuracy of a noninvasive temporal artery thermometer for use in infants.

OBJECTIVES: To assess the accuracy of a new noninvasive temporal artery (TA) thermometer in infants; to compare the accuracy of the TA thermometer with that of a tympanic thermometer, using rectal thermometry as the criterion standard; and to compare the tolerability of the TA thermometer with that of the tympanic and rectal thermometers. DESIGN: Prospective evaluation of the accuracy of TA and tympanic thermometry, using rectal thermometry as the criterion standard. SETTING: Emergency department of an urban pediatric hospital. SUBJECTS: Convenience sample of 304 infants younger than 1 year presenting for care. MAIN OUTCOME MEASURES: Temperatures were measured using TA, tympanic, and rectal thermometers for all infants. Agreement between TA or tympanic and rectal temperatures was assessed. The sensitivity and specificity of TA or tympanic thermometers for detecting rectal fever were determined. Discomfort scores, using a standardized scale, were assessed by trained observers after each temperature measurement was made. RESULTS: Linear regression analysis of the relation between TA and rectal temperatures yielded a model with a slope of 0.79 (vs a slope of 0.68 for tympanic vs rectal temperature; P =.02) and an r of 0.83 (vs r = 0.75 for tympanic vs rectal temperature; P<.001). Among 109 patients with a rectal temperature of 38 degrees C or higher, the TA thermometer had a sensitivity of 0.66 compared with the tympanic thermometer's sensitivity of 0.49 (P<.001). Discomfort scores with TA thermometry were significantly lower than with rectal thermometry (P =.007). CONCLUSIONS: The TA thermometer has limited sensitivity for detecting cases of rectal fever in infants. However, the TA thermometer is more accurate than the tympanic thermometer in infants, and it is better tolerated by infants than rectal thermometry.

Body Temperature↗

Clinical results of radiofrequency hyperthermia for malignant liver tumors.

PURPOSE: To evaluate thermometry and the clinical results of radiofrequency (RF) hyperthermia for advanced malignant liver tumors. METHODS AND MATERIALS: One hundred seventy-three patients with malignant liver tumors treated between 1983 and 1995 underwent hyperthermia. The 173 tumors consisted of 114 hepatocellular carcinomas (HCCs) and 59 non-HCCs (47 metastatic liver tumors and 12 cholangiocarcinomas). Eight-megahertz RF capacitive heating equipment was used for the hyperthermia. Two opposing 25-cm electrodes were generally used for heating the liver tumors. Our standard protocol was to administer hyperthermia 40-50 min twice a week for a total of eight sessions. The liver tumor temperature was measured by microthermocouples when possible. Transcatheter arterial embolization, radiotherapy, immunotherapy, and chemotherapy were combined with hyperthermia treatment in accordance with each patient's liver function. RESULTS: One hundred forty (81%) of the 173 patients who underwent more than four sessions of hyperthermia were evaluated in this study. Thermometry was performed in 77 (55%) of these 140 patients. The maximum tumor temperature, average tumor temperature, and minimum tumor temperature in the HCC were (mean +/- standard error) 41.2 +/- 0.2 degrees C, 40.3 +/- 1.3 degrees C, and 40.1 +/- 0.2 degrees C, respectively. The same thermometry results for non-HCC were 42.3 +/- 0.2 degrees C, 41.2 +/- 0.2 degrees C, and 40.9 +/- 0.2 degrees C, respectively. The maximum and minimum temperatures (41.8 +/- 0.2 degrees C and 40.3 +/- 0.4 degrees C) in the patients with a complete or partial response (CR or PR) were higher than those in the patients with no response or progressive disease (NR or PD) (41.3 +/- 0.5 degrees C and 39.8 +/- 0.4 degrees C), but the difference was not significant. Of the 73 cases with HCC who were evaluated by computed tomography (CT), CR was achieved in 7 (10%), PR in 15 (21%), NR in 37 (51%), and PD in 14 (19%). Of the 45 cases involving liver metastases evaluated by CT, CR was achieved in 3 (7%), PR in 17 (38%), NR in 12 (27%), and PD in 13 (29%). The 1-year cumulative survival rate for HCC patients was 30.0%, and the 5-year survival rate was 17.5%. The 1-year survival of non-HCC patients was 32.5%, and the longest survival was 30 months. The sequelae of hyperthermia included focal fat necrosis in 20 patients (12%), gastric ulceration in 4 (2%), and liver necrosis in 1 (1%). The sequelae of thermometry were severe peritoneal pain in seven patients (11%), intraperitoneal hematoma in one (1%), and pneumothorax in one (1%). CONCLUSION: Even though the thermometry results for liver tumors were not satisfactory, the treatment results are promising. Further clinical trials of RF capacitive hyperthermia for the treatment of advanced liver tumors should be encouraged.

Bile Duct Neoplasms↗

Comparison of tympanic and rectal temperature in febrile patients.

OBJECTIVE: To compare tympanic membrane temperature and rectal temperature in febrile pediatric patients. METHODS: Sixty febrile children were enrolled as continuous enrollment at initial triage. Two readings of ear temperature were taken in each child with Thermoscan infrared thermometer. Rectal temperature was recorded by a digital electronic thermometer. Comparison of both the techniques was done and co-relation co-efficients calculated. Parental preference for both techniques was assessed. RESULTS: It was observed that mean ear temperature was 38.9+/-0.90 C and that for rectal temperature was 38.8+/-0.80 degrees C. The correlation coefficient between the two was 0.994 (p < 0.01). Coefficients for both sites were comparable over a wide age range. The difference between readings taken from two ears was not significant. Temperature ranges over which readings were recorded were quite wide for both techniques. Parental preference for tympanic thermometry over rectal thermometry was noticed. Tympanic thermometry utilizes pyro-electric sensors, to detect infra-red rays emitted from the surface of tympanic membrane. Ear temperatures correlates well with rectal temperatures which have long been considered as "core" temperatures. Parents prefer the technique of ear thermometry which is quick (2 sec), safe and non-invasive and patient resistance for this is also less. CONCLUSION: A non-invasive, non-mucous device which is accurate over a wide range of temperature could be very useful.

Child↗

A proposed standard data file format for hyperthermia treatments.

One of the most critical areas of research essential to improve the clinical use of hyperthermia in cancer therapy is the determination and evaluation of temperature during therapy. In order to improve the dissemination of newly developed thermometry measurement and analysis programs and facilitate the transport of hyperthermia data files between computers for both intra- and inter- institutional use, we propose a standard file format, the Hyperthermia Data Standard (HDS), which can be used for all hyperthermia data. This data file consists of segments of which nine have been defined. The first is an initial /VERSION segment which identifies the file standard. This is followed by eight major segments: 2) a /IDENT segment which contains file and patient identification information; 3) a /TEXT segment containing additional miscellaneous documentation; 4) a /TUMOR segment which provides tumor and treatment site information; 5) a /HSETUP segment which contains treatment setup information; 6) a /FORMAT segment which defines the data segment structure; 7) a /DATA segment containing the actual thermometry data; 8) a /FOLLOWUP segment for documenting patient response; and 9) an /ANALYSIS segment containing summary information. All segments begin and end with a specified delimiter and, except for the first two (/VERSION and /IDENT), may be repeated more than once. For ease in debugging and verifying adherence to the standard, all information in the file is encoded in printable ASCII characters. All segments consist solely of records containing KEYWORDS and KEYWORD VALUES which identify specified information. Certain KEYWORDS are standard, i.e., having specified names and information formats as defined in this document. The /DATA segment consists of ASCII encoded chronological treatment thermometry and other data whose format and structure is identified in the /FORMAT segment. The /ANALYSIS segment provides the flexibility to store the results of any analysis program along with the actual data file for ease of data management. This thermometry data file standard is designed to provide both flexibility and extendability for all possible forms of hyperthermia treatment data. Furthermore, it is designed to provide a simple format which may be easily read by higher level languages. This document is intended for commercial manufacturers and others who are writing programs to document clinical hyperthermia treatments with the intention that they either use this format for their data storage or provide a means to convert their data into this format.(ABSTRACT TRUNCATED AT 400 WORDS)

Body Temperature↗

Accuracy of noninvasive core temperature measurement in acutely ill adults: the state of the science.

Accurate temperature measurement is critical to the assessment and management of temperature fluctuation in the acutely ill adult. Unfortunately, an accurate, noninvasive method to measure core temperature has yet to be established, and current instruments produce a wide range of temperatures for any given patient. This article provides an integrative review of studies comparing selected invasive and noninvasive temperature measurement methods in acutely ill, hospitalized adult patients. Medline and CINAHL databases were searched to locate published studies on temperature measurement in the adult hospitalized patient. A partial list of primary search terms included core temperature measurement, oral temperature measurement, temporal artery thermometry, and tympanic thermometers. Studies that were data based and included comparison of a tympanic, temporal artery, and/or oral noninvasive temperature measurement to a pulmonary artery or esophageal invasive core measurement in an adult population were included in the analysis. The search method produced 223 publications and abstracts for initial review; 23 (10%) met the inclusion criteria. The only study evaluating the use of temporal artery thermometry in the adult population found the instrument to be unreliable. Results also indicate that high-quality evidence supporting the accuracy of tympanic thermometry, the preferred instrument for noninvasive core temperature measurement in many acute care settings, is lacking, and in fact, the most recent high-quality studies evaluating the accuracy of this instrument fail to show support for its use. Evidence does, however, support the use of oral thermometry as an accurate means of temperature assessment in the adult, acutely ill population.

Acute Disease↗

Comparison of Body Temperatures of Goats, Horses, and Sheep Measured With a Tympanic Infrared Thermometer, an Implantable Microchip Transponder, and a Rectal Thermometer.

Body temperature of goats, horses, and sheep was measured, using 3 methods. Tympanic temperature was measured with a tympanic infrared thermometer, subcutaneous temperature was measured with an implantable microchip transponder, and rectal temperature was measured with a digital thermometer. For goats, rectal and subcutaneous temperatures were significantly higher than tympanic temperatures, but rectal and subcutaneous temperatures did not differ significantly. For horses and sheep, rectal temperatures were significantly higher than tympanic and subcutaneous temperatures, and tympanic temperatures were significantly higher than subcutaneous temperatures. Tympanic infrared thermometry correlated well with traditional rectal thermometry in goats and sheep and should be considered as a viable alternative in those species. Additionally, implantable microchip transponders in goats could be used, because those temperatures also correlated well with temperatures derived by rectal thermometry. Due to the poor correlation with rectal thermometry and reaction of some animals to insertion of the tympanic probe, neither of the alternative methods appear to be useful in horses at this time. Tympanic infrared thermometers and implantable microchip transponders were convenient to use and allowed temperature measurements to be obtained more rapidly than when rectal thermometers were used.

Journal Article↗

[Can ear temperature measurement be used in a hospital?].

BACKGROUND: There are two principle means of infrared thermometry: tympanic thermometry and ear canal thermometry. The purpose of this study was to examine the reliability of these ear thermometers compared with the digital rectal thermometer. MATERIAL AND METHODS: We used two different infrared ear thermometers in this study; one type measured the tympanic temperature, the other the temperature in the ear canal. The rectal temperature was defined as the gold standard. The temperatures measured with the ear thermometers were compared to rectal temperature on 213 patients older than 18 years at Haukeland University Hospital. RESULTS: The tympanic and ear canal measurements showed an average of 0.5 and 0.2 degrees Celsius respectively lower than the rectal temperature. The difference between the two types of ear thermometers was 0.4 degrees (p < 0.001, 95% CI 0.18 to 0.42). By using the tympanic thermometer, the sensitivity of detecting fever was 14% and the negative predictive value was 89%. Ear canal thermometry had 55% sensitivity for finding fever and a negative predictive value of 95%. INTERPRETATION: There are many advantages by using ear thermometers, but the accuracy and ability to detect fever is not good enough for it to be recommended in a clinical practice. We recommend using rectal thermometers.

Adolescent↗