Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Sound”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31Linked to original sources

Relation of sound intensity and accuracy of localization.

Tests were carried out on 17 subjects to determine the accuracy of monaural sound localization when the head is not free to turn toward the sound source. Maximum accuracy of localization for a constant-volume sound source coincided with the position for maximum perceived intensity of the sound in the front quadrant. There was a tendency for sounds to be perceived more often as coming from a position directly toward the ear. That is, for sounds in the front quadrant, errors of localization tended to be predominantly clockwise (i.e., biased toward a line directly facing the ear). Errors for sounds occurring in the rear quadrant tended to be anticlockwise. The pinna's differential effect on sound intensity between front and rear quadrants would assist in identifying the direction of movement of objects, for example an insect, passing the ear.

Adolescent↗

Prevalence of different temporomandibular joint sounds, with emphasis on disc-displacement, in patients with temporomandibular disorders and controls.

Temporomandibular joint (TMJ) sounds are very common among patients with temporomandibular disorders (TMD), but also in non-patient populations. A variety of different causes to TMJ-sounds have been suggested e.g. arthrotic changes in the TMJs, anatomical variations, muscular incoordination and disc displacement. In the present investigation, the prevalence and type of different joint sounds were registered in 125 consecutive patients with suspected TMD and in 125 matched controls. Some kind of joint sound was recorded in 56% of the TMD patients and in 36% of the controls. The awareness of joint sounds was higher among TMD patients as compared to controls (88% and 60% respectively). The most common sound recorded in both groups was reciprocal clickings indicative of a disc displacement, while not one single case fulfilling the criteria for clicking due to a muscular incoordination was found. In the TMD group women with disc displacement reported sleeping on the stomach significantly more often than women without disc displacement did. An increased general joint laxity was found in 39% of the TMD patients with disc displacement, while this was found in only 9% of the patients with disc displacement in the control group. To conclude, disc displacement is probably the most common cause to TMJ sounds, while the existence of TMJ sounds due to a muscular incoordination can be questioned. Furthermore, sleeping on the stomach might be associated with disc displacement, while general joint laxity is probably not a causative factor, but a seeking care factor in patients with disc displacement.

Adolescent↗

[Measurement of sound pressure level at outlet of external auditory canal and eardrum].

OBJECTIVE: To evaluate the sound pressure level at outlet of external auditory canal and eardrum, and to observe the range of maximum frequency of sound effect of outlet ear canal, so as to provide exact data for designing personal noise rating instrument and studying the effect of environmental noise on human body, and to provide basis for calibration of noise sound pressure level. METHOD: Sound pressure level at eardrum and outlet of external auditory canal in 30 young people (60 ears) were measured by Audio Scan RM500 at 50 dB SPL narrow band noise with different frequencies (0.25 - 8.00 kHz). RESULTS: At the same frequency, sound pressure levels at eardrum were less than (0.6 +/- 2.6) dB SPL, at outlet of outlet ear canal less than (0.2 +/- 1.8) dB SPL, there were no significant differences between both sound pressure levels (P > 0.05). There were significant differences in sound pressure levels between both places at 1.50 - 8.00 kHz (P < 0.01). The maximum difference was (10.5 +/- 3.4) dB SPL at 2.00 kHz, and the minimum was (0.5 +/- 6.2) dB SPL at 0.50 kHz. CONCLUSION: The effects of increased sound pressure should be considered in the evaluation of environmental noise and the design for individual noise rating meter when the noise frequency was >or= 1.50 kHz.

Adult↗

[Analysis of the sound-insulation effects of control rooms in workshops with noise].

OBJECTIVE: To study the main factors affecting sound-insulation effects of control rooms in workshops with noise, so as to improve the protection. METHODS: The sound-insulation effects of 467 control rooms were determined, and different building materials, structures of door and window, airtight states etc. were analyzed. RESULTS: The affecting factors contributed to the sound-insulation effects (Eta(2)) were in the order: airtight states (0.168), building materials (0.080), structures of window and door (0.030, 0.029), sound pressure levels and frequency spectrum's characteristics (0.008, 0.006). Under airtight state, the sound-insulation effects of different building materials of the rooms were as follows: double bricks [(19.6 +/- 3.5) dB(A)]; single brick [(15.4 +/- 3.4) dB(A)]; plank [(13.1 +/- 1.6) dB(A)] or aluminum alloy plate with glass [(13.4 +/- 2.5) dB(A)] (P < 0.01). Of 4 group rooms, with the same structure of doors but double or single bricks of windows. 3 groups with dormant window had higher sound-insulation effects [(15.9 +/- 2.8), (18.7 +/- 3.6), (19.3 +/- 2.5) dB(A)] than those with casement window [(14.1 +/- 2.4), (14.9 +/- 2.3), (16.5 +/- 2.4) dB(A)] (P < 0.01 or P < 0.05); 2 groups with dehydrated window [(18.7 +/- 3.3), (22.6 +/- 3.8) dB(A)] higher than those with dormant window [(15.9 +/- 2.8), (19.9 +/- 3.0) dB(A)] (P < 0.05). Of 6 group rooms, with the same structure of windows but double or single bricks of doors, only in 1 group with double-layer door had higher sound-insulation effect [(18.7 +/- 3.6) dB(A)] than that with single-layer door [(15.9 +/- 2.8) dB(A)] (P < 0.01). CONCLUSION: The control room should be designed rationally, kept airtight, according to the sound pressure levels and the condition of the workshop.

Environment Design↗

[Heart sound recognition algorithm based on mathematical morphology].

In this paper, a new method was put forward for automatic recognition of the first heart sounds (S1) and the second heart sounds (S2). After the original heart sound signal was preprocessed, the heart sound envelope was extracted by using the mathematical morphology. Then on the heart sound envelope, S1 and S2 were recognized. Eighty heart sound samples collected were used for testing the algorithm. The accuracy of recognition was 86%, and was 100% for the normal heart sound. The result showed that the algorithm proposed in this paper had high performance, which could be used as a basis for further analysis of heart sound.

Algorithms↗

Evaluation of temporomandibular joint sounds. Diagnostic analysis and clinical implications.

This literature review and survey highlights the controversies surrounding the significance of joint sounds in general, the problems and pitfalls of joint sound analysis and interpretation, and the degree of importance given peripheral and temporomandibular joint sounds by physicians and dentists. The instrumentation and devices currently proposed for use in the detection and interpretation of joint sounds may not meet the standards of validity, reliability, sensitivity, and specificity, and as pointed out by one investigator, "The only objectivity currently associated with these instruments is their ability to record sounds of undetermined origin." In addition, no solid evidence is available that these particular sounds, when detected, are both repeatable over time and distinctly characteristic for particular disorders or significant pathologic changes. Some degree of caution should be used, therefore, when interpreting joint sounds in the absence of significant signs and symptoms of temporomandibular disorders. The clinical significance of these same sounds may become more or less apparent relative to the information obtained in a comprehensive temporomandibular disorder evaluation and examination including both subjective and objective pain assessments, mandibular range of motion measurements, and the interpretation of radiologic findings.

Humans↗

[The alterations of occlusal sounds, jaw opening movement and electromyography depend on occlusal interference].

Before crown prosthetese are set on the prepared teeth, occlusal adjustments are normally necessary. Previous studies suggested that the tolerance of occlusal interference is less than 30 microns and that the occlusal sensibility of tooth must be smaller than 30 microns. The purpose of this study was to investigate the possibility of measuring small amounts of occlusal interference by using the occlusal examinations of occlusal sounds, jaw movement and muscle activity. Fifteen subjects participated in this study. They had healthy oral tissue and TMJ. The occlusal interferences were made from platinum foil (25 microns/layer). For 200 microns thickness, 100 microns thickness and 50 microns thickness, multiple-thickness (8, 4 and 2 layers) platinum foils were used. For 25 microns thickness, simple platinum foil was used. And for 15 microns thickness, rolled platinum foil was used. Each occlusal interference was applied on 3 or 6 of the subject in order from the thickest to the thinnest one. For the measuring of occlusal sounds, accelerometers were attached to the skin of each orbital point. For the measuring of jaw movement, a mandibular kinegiograph K-5R (Mio.tronics Co.) was used. Surface electrodes were used for the measurement of muscle activities of masseteres and anterior tempolar muscles. The measurements were performed regularly after the subjects were instructed to start tooth tapping at the speed of three times a second. The results were as follows. 1. When any occlusal interference was put on 3 or 6, both the peak to peak value of occlusal sounds were reduced and the duration of the sounds were increased compared to cases with normal dentition. The duration of the jaw tooth tapping movement and the peak to peak value of muscle activity for tooth tapping didn't show any tendency of change when occlusal interferences were used. However, the duration of muscle activity preceding the onset occlusal sound indicated increasing. 2. When the amount of occlusal interference was reduced, the peak to peak value of occlusal sounds was increased and the duration shortened. The increased or decreased time of the jaw tooth tapping movement depended on the amount of occlusal interference. 3. These findings suggest that the peak to peak value and the duration of occlusal sounds, the duration of the jaw tooth tapping movement, and the duration of muscle activity preceding the onset occlusal sound are useful data for objective assessments of occlusal contacts.

Auscultation↗

[An acoustical analysis of TMJ sounds and its clinical importance].

The aim of this report was to establish a method for objective examination of TMJ sounds which is required for preventive care of the TMJ dysfunction, and to confirm its clinical importance by means of analysis of mandibular border movement and EMG. The subjects for the acoustical analysis of TMJ sounds consisted of 13 temporomandibular joints as the clicking group, 4 as the crepitus group, and 11 as the control group. The subjects for the analysis of the mandibular movement and EMG consisted of 8 adults with clicking as the clicking group and 11 without TMJ sounds as the control. The results obtained were as follows: 1. Clear and stable TMJ sounds waves could be recorded from the external auditory meatuses. 2. Clicking sounds waves showed a sharper rising and shorter duration than crepitus sounds waves. Comparing the three groups on the basis of the data of power spectrum analysis of frequencies using FFT, the spectrum of frequencies of the crepitus group was the highest and broadest, and that of control group was the lowest. 3. The deviation of the trace of mandibular border movement in the clicking group tended to be larger than in the control group. 4. In the clicking group, the frequency of occurrence of the silent period of EMG bursts during tooth tapping was lower and the duration of the silent period was shorter than in the control group. Duration, interval and cycle of EMG bursts during gum chewing in the clicking group was longer than in the control group. 5. From the above, it was suggested that the ones with TMJ sounds had the TMJ dysfunction latently, therefore it was considered valuable to use an analysis of TMJ sounds in the examination for the preventive care of the TMJ dysfunction.

Humans↗

[New classification and analysis of lung sounds].

Recently, classification and nomenclature of lung sounds has been changed from assessment based on subjective interpretation to assessment based on objective, measureable criteria related to mechanisms of sound generation. The adventitious sounds was classified to four kinds of principal terms, continuous adventitious sounds (wheezes, rhonchi) and discontinuous adventitious sounds (coarse crackles, fine crackle) at the 1985 International Symposium on Lung Auscultation. Lung sounds in the surgical patients were digitized for the analysis of both the time domain and the frequency domain which had been recorded by tape recorder. Rhonchi, fine crackle and tracheal stenotic sounds were characterized by the analysis of the frequency domain. Lung sound analysis is promising because it is safe, non invasive and may be used for clinical studies in the surgical patients.

Humans↗

Xinyinqin: a computer-based heart sound simulator.

"Xinyinqin" is the Chinese phoneticized name of the Heart Sound Simulator (HSS). The "qin" in "Xinyinqin" is the Chinese name of a category of musical instruments, which means that the operation of HSS is very convenient--like playing an electric piano with the keys. HSS is connected to the GAME I/O of an Apple microcomputer. The generation of sound is controlled by a program. Xinyinqin is used as a teaching aid of Diagnostics. It has been applied in teaching for three years. In this demonstration we will introduce the following functions of HSS: 1) The main program has two modules. The first one is the heart auscultation training module. HSS can output a heart sound selected by the student. Another program module is used to test the student's learning condition. The computer can randomly simulate a certain heart sound and ask the student to name it. The computer gives the student's answer an assessment: "correct" or "incorrect." When the answer is incorrect, the computer will output that heart sound again for the student to listen to; this process is repeated until she correctly identifies it. 2) The program is convenient to use and easy to control. By pressing the S key, it is able to output a slow heart rate until the student can clearly identify the rhythm. The heart rate, like the actual rate of a patient, can then be restored by hitting any key. By pressing the SPACE BAR, the heart sound output can be stopped to allow the teacher to explain something to the student. The teacher can resume playing the heart sound again by hitting any key; she can also change the content of the training by hitting RETURN key. In the future, we plan to simulate more heart sounds and incorporate relevant graphs.

Computer Simulation↗

[Automated analysis of all-night records of tracheal sound to detect sleep disordered breathing].

In sleep-disordered breathing, tracheal sounds disappear during apnea and vary cyclicly during hypopnea. We tried to detect these changes in tracheal sounds automatically with a personal computer, and we evaluated the diagnostic accuracy of this system for detecting sleep-disordered breathing. Polysomnography and tracheal sound recording were done in 33 subjects with possible sleep apnea/hypopnea syndrome. Eighteen had positive results defined as an apnea/hypopnea index greater than 15. Tracheal sounds were digitized and a personal computer was used to calculate short time power spectra (44-600 Hz) every 0.2 seconds by the fast Fourier transform. The moving averages (18 seconds) of the logarithms of the power spectra were calculated every 2 seconds. Transient falls in the moving averages of more than 12 dB were detected. Those that were lower than 5 dB above the level of background noise were classified as tracheal sound apneas. The number of falls of more than 12 dB and the number of tracheal sound apneas correlated strongly with the number of apneas plus hypopneas (r = 0.95) and with the number of apneas (r = 0.97), respectively. The sensitivity and specificity of tracheal sound analysis for the sleep apnea/hypopnea syndrome (as defined above) were 89% and 60%, respectively, when the criteria was more than 15 falls of more than 12 dB per hour. We conclude that tracheal sound analysis by this method is useful as a screening test for the sleep apnea/hypopnea syndrome.

Adult↗

Impaired recognition of meaningful sounds in Alzheimer's disease.

We studied recognition of meaningful nonverbal sounds using a sound-picture matching test in 18 patients with senile dementia of the Alzheimer type (SDAT) and 19 age-matched controls. A significant impairment of sound recognition was found in the SDAT group, consistent with auditory sound agnosia. Although sound recognition performance correlated significantly with auditory verbal comprehension scores, a sound recognition defect was also identifiable in the subgroup of patients with SDAT who had normal verbal comprehension. Qualitative analysis of sound recognition errors revealed that nonaphasic patients with SDAT made predominantly acoustic errors, whereas semantic errors were found almost exclusively in aphasic patients. These findings suggest that the auditory sound agnosia of patients with SDAT may be subdivided into perceptual-discriminative and semantic-associative types.

Aged↗

Long lasting attenuation by prior sounds in auditory cortex of awake primates.

How the brain responds to sequences of sounds is a question of great relevance to a variety of auditory perceptual phenomena. We investigated how long the responses of neurons in the primary auditory cortex of awake monkeys are influenced by the previous sound. We found that responses to the second sound of a two-sound sequence were generally attenuated compared to the response that sound evoked when it was presented first. The attenuation remained evident at the population level even out to inter-stimulus intervals (ISIs) of 5 s, although it was of modest size for ISIs >2 s. Behavioral context (performance versus non-performance of a visual fixation task during sound presentation) did not influence the results. The long time course of the first sound's influence suggests that, under natural conditions, neural responses in auditory cortex are rarely governed solely by the current sound.

Acoustic Stimulation↗

Movement and sound generation by the toadfish swimbladder.

Although sound-producing (sonic) muscles attached to fish swimbladders are the fastest known vertebrate muscles, the functional requirement for such extreme speed has never been addressed. We measured movement of the swimbladder caused by sonic muscle stimulation in the oyster toadfish Opsanus tau and related it to major features of the sound waveform. The movement pattern is complex and produces sound inefficiently because the sides and bottom of the bladder move in opposite in and out directions, and both movement and sound decay rapidly. Sound amplitude is related to speed of swimbladder movement, and slow movements do not produce perceptible sound. Peak sound amplitude overlaps fundamental frequencies of the male's mating call because of muscle mechanics and not the natural frequency of the bladder. These findings suggest that rapid muscle speed evolved to generate sound from an inefficient highly damped system.

Action Potentials↗

Hardness and elasticity of bonded carious and sound primary tooth dentin.

OBJECTIVE: Although biomechanical properties of bonded dentin are important for resin restorations, no information for primary teeth has been reported. This study evaluated the hardness and elastic modulus of bonded carious and sound primary tooth dentin using two adhesive systems. METHODS: Twelve sound primary molars and 17 carious primary molars were bonded with Clearfil SE Bond (SE: Kuraray) or Single Bond (SB: 3M) and the resin-dentin interface was measured with a nano-indentator and observed with a SEM. Data was statistically analyzed using ANOVA subsequent application of Fisher's PLSD at p<0.01. RESULTS: Compared to the dentin beneath the interface, the hardness of the interface dentin was not significantly different (carious-SE, sound-SE and sound-SB groups) or was significantly higher (carious-SB group). Young's modulus of the interface dentin was not significantly different (carious-SE, carious-SB and sound-SB groups) or was significantly lower (sound-SE group) than that for the dentin beneath the interface. In the comparison of the measurement on the interface dentin, the hardness showed no significant differences among all the groups. The Young's modulus of the sound-SE group was significantly lower than that of the carious-SE and sounds-SB groups, but no significant difference was observed between the carious-SB and other groups. CONCLUSIONS: Physical properties of bonded primary tooth dentin might differ from that of permanent tooth dentin.

Analysis of Variance↗

The neuroanatomical substrate of sound duration discrimination.

We investigated the neuroanatomical substrate of sound duration discrimination, using the same experimental design as in a previous study on sound intensity discrimination [J. Neurosci. 18 (16) (1998) 6388]. Seven normal subjects were trained to detect deviant sounds presented with a slightly longer duration than a 300 ms long standard harmonic sound, using a Go/No Go paradigm. Individual psychometric curves were assessed using a three-step psychoacoustic procedure. Subjects were then scanned while passively listening to the standard sound, and while discriminating changes in sound duration at four different performance levels (d'=1.5, 2.5, 3.5 and 4.5). Analysis of regional cerebral blood flow (rCBF) data outlined activation, during the discrimination conditions, of a right hemispheric fronto-parietal network very similar to the one previously observed for intensity discrimination, as well as additional activation in the right prefrontal cortex (Brodmann Area (BA) 10), bilateral basal ganglia and cerebellar hemispheres. These findings suggest that discrimination of sound duration, as for discrimination of sound intensity, involves two cerebral networks: a supramodal right fronto-parietal cortical network responsible for allocation of sensory attentional resources, and a network of regions such as the basal ganglia, cerebellum, and right prefrontal cortex, more specifically involved in the temporal aspects of the discrimination task.

Acoustic Stimulation↗

Underwater sounds near a fuel receiving facility in western Hong Kong: relevance to dolphins.

Western Hong Kong is home to two species of marine mammals: Indo-Pacific humpbacked dolphins (Sousa chinensis) and finless porpoises (Neophocaena phocaenoides). Both are threatened in many parts of their range in southeast Asia [for example, International Biological Research Institute Reports 9 (1997), 41; Asian Marine Biology 14 (1997) 111]. In 1998, when the new Hong Kong International Airport opened in western Hong Kong, small tankers (about 100 m long, cargo capacity about 6300 metric tons) began delivering fuel to the Aviation Fuel Receiving Facility (AFRF) just off Sha Chau Island, north of the airport. Calibrated sound recordings were taken over a 4-day period from a quiet, anchored boat at distances 80-2000 m from aviation fuel delivery activities at the AFRF. From the recordings, 143 sections were selected for analysis. Narrowband spectral densities on the sound pressures were computed, and one-third octave band levels were derived for center frequencies from 10 to 16,000 Hz. Broadband levels, viz. 10-20,000 Hz. were also computed. The results showed that the Sha Chau area is normally noisy underwater, with the lowest broadband levels measured corresponding to those expected during a storm at sea (sea state 6). This background noise is believed to come largely from heavy vessel traffic in the Urmston Road to the north and east of Sha Chau and from vessels in the Pearl River Estuary to the West. The sound levels from the AFRF tankers are comparable to the levels measured from similar- and smaller-sized supply vessels supporting offshore oil exploration. The strongest sounds recorded were from a tanker leaving the AFRF at distance 100 m from the hydrophone, for which the one-third octave band level at 100 Hz was 141 dB re 1 microPa (spectrum level 127 dB re 1 microPa2/Hz) and the 10-20,000 Hz broadband level was 146 dB. At distances of 100 m or more and frequencies above 300 Hz, the one-third octave band levels were less than 130 dB (spectrum level 111 dB re 1 microPa2/Hz) and decreased with increasing frequency and distance. At distances greater than about 500 m, AFRF-associated sounds were negligible, masked by the generally high noise level of the area and attenuated by poor transmission in the very shallow water (<10 m). Because it is believed that humpbacked dolphins and finless porpoises are not very sensitive to sounds below 300 Hz, the Airport Authority Hong Kong (AA) stipulated that dedicated terminal vessels not radiate underwater sounds at spectrum levels greater than 110 dB re 1 microPa2/Hz at frequencies above 300 Hz and distances greater than 300 m. The spectrum levels at 300 Hz and higher frequencies of sounds from the tankers arriving, departing, or off-loading at AFRF were less than 110 dB re 1 microPa2/Hz even at distances of 200 m or less. The AA stipulation was met. However, it is presently unknown whether the generally strong noise levels of western Hong Kong inhibit acoustically based feeding and communication, or result in increased stress or permanent shifts in hearing thresholds.

Animals↗

The functional value of sound and exploratory behaviour in detelencephalated pigeons.

Exploratory behaviour in response to a sound previously paired to a shock was analyzed before and after massive telencephalic lesions. Six pigeons were submitted to sound shock associations, habituation tests, telencephalic lesion and habituation retesting. Eighteen birds divided into three sham-lesioned groups received sound shock pairing (Control 1), pre-exposure to sound stimulation (Control 2) or pre-exposure to electric shocks (Control 3) before the behavioural tests. The pre-surgery tests consisted of 25 1 s pulses of sound A (1000 Hz, 83 dB) or B (500 Hz, 85 dB), every 30 s. Retests took place 10 days after surgery using the same sequence of procedures. The behaviour exhibited immediately after each sound stimulation was recorded manually and on video during the sessions. Analysis of variance showed an effect of group {F(3, 20)= 13.37, p < 0.0001) suggesting that pre-exposure to tone-shock association affected the exploration in response to the sound presented in another context. The Experimental and Control 1 birds showed no robust decrease in responses during the pre-surgery sessions. Post-surgery exploration data for detelencephalated birds showed a lower level of responding (p < 0.05). These data suggest a retardation in the typical reduction of responses to recurrent stimulation and support other evidences of the potentiating effect of sound shock association on responding. They are also indicative of telencephalic modulation of exploratory behaviour and strengthen the arguments for the subtelencephalic storage of associative information concerning the functional value of acoustic stimulation.

Acoustic Stimulation↗