Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PYRROLIDONES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31Linked to original sources

Additional possible tools for identification of proteins on one- or two-dimensional electrophoresis.

Additional, essentially chemical, identification methods of proteins in polyacrylamide gel electrophoresis are described. Two cleavages of peptide bonds were used at the C-side of aspartic acid with a 0.2% pentafluoropropionic acid (PFPA) aqueous vapor at 90 degrees C for 4-16 h, and the N-side of serine/threonine with an S-ethyl trifluorothioacetate vapor at 50 degrees C for 6-24 h. The products were analyzed by mass spectrometry-peptide mass fingerprinting. A new type of C-terminal sequencing at multisites of protein was introduced. An aqueous vapor of 90% PFPA at 90 degrees C for 2-16 h provided cleavages at the C-side of aspartic acid and the N-side of serine/threonine and simultaneous successive truncation at the C-termini of the cleaved fragments. The product resulted in C-terminal sequences at multisites in proteins by mass spectrometric analysis. The following chemical deblocking methods were used. Anhydrous hydrazine vapor at -5 degrees C for 8 h deblocked the N-formyl group, and the vapor at 20 degrees C for 4 h deblocked pyrrolidone carboxylate. N-acetylserine/threonine was deblocked by aqueous vapor of 75% PFPA at 50 degrees C for 1 h, followed by reaction with p-sulfophenylisothiocyanate at pH 6.0. These methods were applied to a variety of protein spots on polyacrylamide gels. A new stepwise C-terminal sequencing of protein from polyacrylamide gels is also described.

Amino Acid Sequence↗

DNA capillary electrophoresis using poly(vinyl alcohol). II. Separation media.

We represent the first extensive study on DNA capillary electrophoresis using various poly(vinyl alcohol) (PVAL)-related polymers as separation media. As a separation medium, PVAL homopolymer has shown poor resolutions probably due to its very strong hydrogen-bonding characteristics, resulting in extensive self-aggregation. On the other hand, poly(vinyl alcohol-co-vinyl acetate) and poly(vinyl alcohol-co-1-vinyl-2-pyrrolidone) (PVAL-VP), both with a degree of polymerization of approximately 3.0x10(3), have been found to give excellent electropherograms with good resolutions for the analysis of double-stranded (ds)DNA. PVAL-VP, with hydrolytic stability in high and low pH regions, has also yielded fair electropherograms for single-stranded (ss)DNA under neutral and alkaline conditions, although further investigation is essential in order to increase the resolutions necessary for DNA sequencing analysis. The separations obtained under alkaline conditions have shown significantly shorter retention times, one-third of that for the current commercial separation media, due to the higher ionization of phosphate groups in the DNA chains.

DNA↗

Methadone-disulfiram interaction during methadone maintenance.

In an attempt to characterize a possible drug interaction between methadone and disulfiram, 500 mg/day insulfiram was administered orally for seven days to seven subjects on methadone maintenance. Plasma methadone concentrations and urinary excretion of methadone and its pyrrolidine and pyrrolidone metabolites were measured and subjective symptoms of opiate intoxication and abstinence were noted before, during, and after disulfiram administration. Mean trough plasma methadone concentrations and terminal half-lives were lowest and shortest during disulfiram treatment, although this finding was not statistically significant. The ratio of urinary methadone to its pyrrolidine metabolite decreased during disulfiram treatment in all subjects. There is no evidence to support our original hypothesis that disulfiram might inhibit methadone metabolism. In contrast, urinary excretion of the major pyrrolidine metabolite increased relative to excretion of methadone. This suggests enhanced N-demethylation during disulfiram treatment. Disulfiram had no effect on opiate intoxication or abstinence symptoms. Disulfiram may alter methadone disposition, but in this study it was shown that in doses used for management of alcoholism there was no significant interaction between disulfiram and methadone.

Adult↗

Immobilization of heparin oligosaccharides onto radiofrequency plasma modified pyrolytic carbon-coated graphite.

Heparin oligosaccharides with different anticoagulant activities were prepared and immobilized onto pyrolytic carbon coated graphite (PC) heart valve materials commonly used in mechanical heart valve prostheses. Prior to immobilization, PC surfaces were modified by radiofrequency plasma polymerized N-vinyl-2-pyrrolidone (PPNVP) thin films (approximately 100 nm) and derivatized to provide surface hydroxyl groups. Cleaved, low affinity heparin (C-heparin) with factor Xa inhibition activity of 107 to 130 IU/mg, was prepared by partial deaminative cleavage of commercial crude heparin, and high-affinity heparin (HA-heparin) with factor Xa inhibition activity of 550 to 1000 IU/mg was prepared by fractionation of C-heparin using agarose-ATIII affinity chromatography. C-heparin and HA-heparin were immobilized to surface modified PC by reductive amination. Anticoagulant activity of the heparin immobilized surfaces was determined by chromogenic assay for the inhibition of factor Xa. Highest surface anticoagulant activity was measured on C-heparin immobilized surfaces (64.0 +/- 7.3 mIU/cm2) compared with HA-heparin immobilized surfaces (27.2 +/- 12.2 mIU/cm2), suggesting higher binding of C-heparin than HA-heparin on the modified PC surfaces. Immobilized surfaces were evaluated under dynamic flow conditions, by subjecting samples to shear stress of up to 206 dyn/cm2 in the presence of 5% albumin solution or human plasma. Anticoagulant activity of the immobilized heparin was retained, although reduced, and the modified surfaces showed evidence for protein resistance.

Anticoagulants↗

Relationship between solubility and hemolytic effects of toxic dusts.

Two varieties of native and chemically treated slate dust were tested in vitro for their hemolytic effects and the extent of silicic acid dissolution in various physiological fluids. The extent of hemolysis was found to be proportional to the degree of dissolution of dust constituents. Membrane lysis by the dust appeared to be prevented by coating it with polyvinyl pyrrolidone, serum proteins and pulmonary lavage lipids. The significance of the findings is discussed.

Animals↗

Binding of silicic acid by proteins and its relation to toxicity of silicate dusts.

A possible mechanism of biological effects of silicate dusts is the interaction between silicic acid and tissue constituents, and this has been studied in vitro. On incubating silicic acid with lung homogenate, appreciable amounts of silicon were recovered in the trichloroacetic acid precipitate in both organic solvent extract and residual protein. Polyvinyl pyrrolidone inhibited this interaction as well as reducing the dissolution of silicic acid from asbestos dust. The capacity of serum albumin to bind silicic acid was also observed. Chemical interaction between macromolecules and silicic acid could be one of the factors responsible for the biological effects of silicon-containing dusts.

Animals↗

Interrelationship between hemolysis and lipid peroxidation of human erythrocytes induced by silicic acid and silicate dusts.

Silicic acid and silicate dusts (slate dust and chrysotile asbestos) cause hemolysis of erythrocytes in vitro. The peroxidation of polyunsaturated fatty acids (PUFA) of erythrocyte membrane lipids is also enhanced by incubating the erythrocytes with silicic acid and silicate dusts in in vitro. Hemolysis of erythrocytes elicited by silicic acid and silicate dusts is inhibited significantly by polyvinyl-pyrrolidone and dipalmitoyl lecithin (DPL). These agents, however, have no effect on silicic acid and silicate dust induced peroxidation of erythrocyte membrane lipids. On the other hand, peroxidation of erythrocyte membrane lipids, induced by silicic acid and silicate dusts, is inhibited almost completely by adding superoxide dismutase and catalase to the incubation system, whilst the hemolysis of erythrocytes induced by silicic acid and silicate dusts is unaffected by these agents. Similarly the lysis of erythrocytes, induced by silicic acid and silicate dusts, proceeds at a much faster rate than silicic acid and silicate dust induced lipid peroxidation. These results indicate that silicic acid and silicate dust induced hemolysis and lipid peroxidation represent two independent processes.

Asbestos↗

Cell adhesion to polymeric materials: implications with respect to biocompatibility.

The adhesion of radio-labeled chick embryo muscle cells to the surfaces of radiation grafted hydrogels and other polymeric materials was measured in vitro. The degree of adhesion was determined by measuring the percentage of cells which remained adherent to the surfaces after 180 min of contact time (plating efficiency). Plating efficiency was found to vary between 2 and 94% depending on the nature of the surface. Preadsorption of albumin, gamma-globulin or fibrinogen markedly affected subsequent adhesion of cells. Radiation grafted poly(2-hydroxyethyl methacrylate) and poly(N-vinyl-2-pyrrolidone) hydrogels on silicone rubber demonstrated exceptionally low adhesiveness in this assay. The potential for using this cell adhesion assay as a general screening test for biomaterials is discussed.

Adsorption↗

Biocompatibility of polymeric delivery systems for macromolecules.

We previously reported the use of polymeric delivery systems capable of sustained release of substances with molecular weights up to 2 X 10(6). The current study examined the tissue compatibilities of these slow-release agents and of other polymeric materials. To observe in vivo host responses to specific implants, tests were conducted in the rabbit cornea. The cornea as an implant site has several advantages compared to other organs including its clarity, avascularity, sensitivity, and convenient access to view. Corneas were examined using stereomicroscopy and histology. Two polymers suitable for sustained macromolecular release, poly(hydroxyethyl methacrylate), and alcohol-washed ethylene-vinyl acetate copolymer, were noninflammatory. Other polymers considered for sustained macromolecular release, such as polyacrylamide and poly(vinyl pyrrolidone), produced significant inflammation.

Animals↗

Ex vivo shunt testing of hydrogel-silicone rubber composite materials.

Hydrogel polymers consisting of HEMA (2-hydroxyethyl methacrylate) alone or co-polymerized with NVP N-(vinyl pyrrolidone) were incorporated into silicone rubber tubing to produce hydrophilic composite materials. Polymerization methods of the interpenetrating network (IPN) and radiation-induced type were used to impregnate the silicone rubber substrates. These methods produced materials with varied wettability (contact angle with water ranged from 57 degrees to 95 degrees) but similar texture. The surface morphology as observed in the scanning electron microscope was the same for all the materials. Four types of composite materials and two sizes of silicone rubber control tubing in a total of 19 dogs were used as ex vivo femoral artery-to-vein (A-V) shunts and were sampled at 5, 15, 30, 45, and 60 min. Data obtained by using scanning electron microscopy (SEM) were used to determine the type and amount of adhering blood cells at the time intervals described. Large platelet aggregates and/or a variable initial response were found to be predictors of shunt failure (occlusion). Most samples showed only varied levels of platelet adhesion, but other cell types were seen in some samples. The adhesion was found to peak in all cases by 30 min and to reach lower levels by 60 min, suggesting that an initial phase of reaction was complete. The course of platelet adhesion for a 60-min period is presented.

Animals↗

Evaluation of in vivo adsorption of blood elements onto hydrogel-coated silicone rubber by scanning electron microscopy and fourier transform infrared spectroscopy.

Three hydrogel formulations consisting of 2-hydroxyethyl methacrylate (HEMA) copolymerized with N-vinyl pyrrolidone (NVP) were incorporated into silicone rubber by irradiation-induced polymerization. These coatings were chosen to represent different degrees of hydrophilicity, and they changed the hydrophobic character of the silicone rubber surface to that of hydrophilic. These composite materials and the silicone rubber comparison material were used as femoral artery-to-vein (A-V) shunts and were removed at 15 min, an approximate time representative of an initial buildup stage of blood elements on test surfaces. Data obtained by scanning electron microscopy (SEM) were used to determine the type and amount of adhering blood cells and fibrin at the time interval described. One-half of each specimen was used for Fourier Transform Infrared (FT-IR) analysis to provide a direct comparison of the relative amounts of protein present on the silicone rubber and the three hydrogel composite samples. The combined SEM and FT-IR analyses were performed on A-V samples from three dogs. Differences in the response of blood to the surfaces were found by the combined SEM and FT-IR analyses. The more hydrophilic a hydrogel grafted surface, the less fibrin and cellular elements were seen deposited on it. This is not interpreted as an indication of less reactivity, but is more likely due to thrombus buildup and a degree of subsequent embolization (a tearing of sections of the platelet matting away from a surface, revealing an area that again can be covered.

Acrylates↗

A hydrophilic plasma polymerized film composite with potential application as an interface for biomaterials.

A hydrophilic polymer composite film (approx. 420 nm thick), with potential application as an interface for biomaterials has been prepared on nonorganic substrates, which include glass, silicon, and aluminum foil, using a glow discharge plasma polymerization technique. A thin film (110 nm thick) polymerized from hexane provided an adherent protective coating for the substrate material, and covalent bonding sites for the outer layer polymerized from N-vinyl-2-pyrrolidone. This outer layer provided the hydrophilic surface or interface. The two layers were copolymerized for a short period during transition between monomers to provide an intimate covalently bonded diffuse interphase. Preliminary in vitro and in vivo biocompatibility studies indicate that the hydrophilic film is non-cytotoxic, and does not increase the inflammatory response when compared with negative controls.

Animals↗

Biocompatibility studies on plasma polymerized interface materials encompassing both hydrophobic and hydrophilic surfaces.

The biocompatibility of radiofrequency plasma polymerized films (less than 100 nm thick) deposited on biomedical polymer supports has been characterized by in vitro and in vivo methods. The polymer interface materials covered a wide range of elemental composition and surface properties, and were prepared from N-vinyl-2-pyrrolidone, gamma-butyrolactone, n-hexane, and hexamethyldisilazane (PPHMDSZ). The biocompatibility studies showed that the interface materials were noncytotoxic to mouse and human fibroblasts, as shown by morphologic evaluation, and by determination of extracellular LDH; and they did not stimulate interleukin-1-like production from human monocytes, as indicated by a thymocyte proliferation assay. The human fibroblast proliferation assay showed that three of the polymers supported cell growth at levels comparable to, or greater than, polymer controls, while the hydrophobic PPHMDSZ inhibited both cell attachment and proliferation. The response to subcutaneous implantation for all test materials was indicative of biocompatibility, with rapid resolution of the acute phase response and normal wound healing. The wide range of composition and surface properties for the plasma polymerized films evaluated in this study suggest that this general class of materials is likely to exhibit excellent biocompatibility.

Animals↗

Bacterial adhesion to poly(HEMA)-based hydrogels.

The effects of water content and comonomer chemistry upon the adhesion of Pseudomonas aeruginosa to poly(hydroxyethyl methacrylate)-based hydrogels were studied. Hydrogels which varied in swollen water content from 33-69 wt% were polymerized onto glass microscope slides pretreated with a vinyl silane. The hydrogel water content was varied by adding methacrylic acid (1-5 wt%) or N-vinyl pyrrolidone (NVP, 10-25 wt%) or combinations of the two comonomers. The resulting hydrogel surfaces, which were 0.1 mm thick, transparent, and adherent to the glass slide, formed the test surfaces of laminar flow cells (Re = 1.3, wall shear rate = 1.6/s). The bacteria were grown for 8 h in tryptic soy broth (TSB), washed by filtration, and collected on 0.45-microns filters, resuspended in phosphate buffered saline (PBS) at pH = 7.2, and recirculated through the flow cell and across the test surface at 0.85 mL/min for 2 h. Results show that P. aeruginosa adhered less to hydrogels with higher water contents. In the presence of TSB and possible poly(NVP) contamination, the concentration of adherent bacteria was reduced to low and uniform levels independent of the hydrogel chemistry.

Bacterial Adhesion↗

Immobilization of high-affinity heparin oligosaccharides to radiofrequency plasma-modified polyethylene.

Oligosaccharides of heparin with high affinity for antithrombin III (ATIII) have been immobilized onto surface-modified NHLBI Primary Reference low density polyethylene (PE). PE was modified by radiofrequency plasma polymerized (< 150 nm thick) films derived from N-vinyl-2-pyrrolidone (PPNVP) or allyl alcohol (PPAA), and coupled by chemical derivatization to either 3-aminopropyltriethoxysilane or amino-terminated poly(ethylene oxide). High affinity heparin oligosaccharides (HA-heparin, anti-factor Xa activity of 592 +/- 120 IU/mg) prepared by partial deaminative cleavage of commercial crude heparin and fractionated by agarose-ATIII affinity chromatography, were immobilized to surface-modified PE by reductive amination. The anticoagulant activity, as determined by a chromogenic assay for the inhibition of factor Xa, was estimated to be 30-70 mIU/cm2, with binding estimated to be 56-119 ng/cm2. The highest activity was obtained for the HA-heparin immobilized to PE modified by PPNVP with a PEO spacer. Visual confirmation of ATIII binding to immobilized HA-heparin was demonstrated by a gold-labeled double antibody method with imaging by SEM.

1-Propanol↗

Analysis of a vinyl pyrrolidone/poly(propylene fumarate) resorbable bone cement.

A resorbable bone cement was formulated from N-vinyl-2-pyrrolidinone (VP), the unsaturated polyester poly(propylene fumarate) (PPF), and the inorganic filler tribasic calcium phosphate (hydroxy apatite). Cure, initiated by benzoyl peroxide and accelerated by N,N-dimethyl-p-toluidine, resulted in the formation of VP crosslinks between polyester chains. During cure the cement hardened from a viscous moldable putty to a rigid structure with a shore D hardness of 50-60. The purpose of this study was to determine the fractions of PPF and VP incorporated into the crosslinked structure. Dissolution of the cured cement in water followed by extraction of the residue in tetrahydrofuran indicated that over 90% of the PPF was crosslinked over the range of PPF/VP ratios explored, but that the fraction of VP used in formation of crosslinks depended linearly on the PPF/VP ratio. Kinetic analysis of these data suggests that k'pp/kpf (the reactivity ratio) was approximately 2.0 where k'pp is the rate constant for the addition of VP radical to VP monomer leading to formation of poly(vinyl pyrrolidone), and kpf is for the addition of VP radical to PPF unsaturation.

Biocompatible Materials↗

Novel associated hydrogels for nucleus pulposus replacement.

Hydrogels of poly(vinyl alcohol) (PVA) and poly(vinyl pyrrolidone) (PVP) blends may provide a material suitable for replacement of the nucleus pulposus of the intervertebral disc. This research examined the stability of these hydrogels under simulated physiological conditions. Polymer dissolution and stability were characterized over 120 days immersion, chemical surface analysis over 56 days immersion, and tensile mechanical behavior over 56 days immersion. Rubber elasticity theory was used by combining mechanical results with swelling data to calculate network characteristics such as the molecular weight between physical crosslinks and density of crosslinks. Properties were examined as a function of PVA/PVP composition as well as PVA molecular weight and PVP molecular weight. Results indicated that PVA/PVP blends prepared with moderate amounts of PVP (0.5-5%) resulted in a polymer network stabilized through interchain hydrogen bonding between hydroxyl groups on PVA chains and carbonyl groups on PVP chains. Most notably, a significant decrease in percentage of polymer mass loss was seen for blends prepared with 143K molecular weight PVA. Surface chemical analysis revealed that PVP unincorporated in the network structure suffered significant dissolution out of the polymer network and into solution. The molecular weight of PVA and PVP were shown to have a significant influence on the blends' network properties. Gels prepared with lower molecular weight PVA resulted in a more stable blend containing a higher density of crosslinks. However, blends prepared with a higher molecular weight PVA showed superior polymer network stability in dissolution studies. The blend that had the best combination of network stability under physiological conditions and a relatively tight, stable, and crosslinked network was prepared with 99% PVA (143K) and 1% PVP (40K). This material is proposed as an implant material for replacement of the degenerated nucleus pulposus.

Biocompatible Materials↗

Biodegradable porous polyurethane scaffolds for tissue repair and regeneration.

Critical-size bone defects usually require the insertion of autogenous bone graft to heal. Harvesting of bone is traumatic and results in high morbidity at the donor site. A potential alternative to bone graft may be a bone substitute with adequate biocompatibility and biological properties produced from ceramics or bioresorbable/biodegradable polymers. In the present study, new elastomeric biodegradable polyurethanes with an enhanced affinity toward cells and tissues were synthesized using aliphatic diisocyanate, poly(epsilon-caprolactone) diol, and biologically active 1,4:3,6-dianhydro-D-sorbitol (isosorbide diol) as chain extender. The polymers were processed into 3D porous scaffolds by applying a combined salt leaching-phase inverse process. The critical parameters controlling pore size and geometry were the solvents and nonsolvents used for scaffold preparation and the sizes of the solid porogen crystals. Scaffolds prepared from the polymer solution in solvents such as dimethylsulfoxide or methyl-2-pyrrolidone did not have a homogenous pore structure. Many pores were interconnected, but numerous pores were closed. Irrespective of the high pore-to-volume ratio (75%), the scaffolds showed poor water permeability. The best solvent for the preparation of scaffolds from the polyurethane used in the study was dimethylformamide (DMF). The type of nonsolvent admixed to the polymer solution in DMF strongly affected the scaffolds' pore structure. The elastomeric polyurethane scaffold prepared from the optimal solvent-nonsolvent mixture had regular interconnected pores, high water permeability, and a pore-to-volume ratio of 90%. The osteoconductive properties of the 3D porous polyurethane scaffolds can be additionally promoted by loading them with calcium phosphate salts such as hydroxyapatite or tricalcium phosphate, thus making them promising candidates for bone graft substitutes.

Absorbable Implants↗