Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PROSTHESIS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31Linked to original sources

[Early results of proximal interphalangeal joint replacement with pyrolytic carbon prosthesis (Ascension) in idiopathic and post-traumatic arthritis].

Surgical treatment of painful idiopathic and post-traumatic arthritis with joint replacement of the proximal interphalangeal joint has become increasingly important. Due to shortcomings of former constrained and partially constrained prostheses with regard to abrasion and durability we have been using an unconstrained prosthesis since April 2002. This model is an almost abrasion free, biocompatible 2-component prosthesis. The surface is shaped like the condyles and the position is secured in a press-fit technique. During October 2004 we reviewed the results of 20 out of 29 patients with idiopathic or post-traumatic arthritis who had been treated with a pyrolytic carbon proximal interphalangeal joint prosthesis from April 2002 to April 2004 retrospectively. Clinical, subjective and radiological parameters were studied. On follow-up after 0.5 to 2.5 years the patients were satisfied with the pain relief. The range of motion varied. However, with an average ROM of 50 degree it was equivalent to the results in literature. Signs of periprosthetic cysts, osteophytes and loosening of the proximal as well as of the distal component could be seen in the radiograms of some patients. There was no correlation between these radiological observations and range of motion, pain or grip strength. In three cases the joint prosthesis had to be converted to an arthrodesis of the proximal interphalangeal joint. Bearing in mind the correct indications (intact collateral ligaments, stable bone stock and sufficient extensor and flexor tendons), pyrocarbon prosthesis are a treatment option for idiopathic and posttraumatic arthritis preserving motion and reducing pain. Radiological results seem to indicate an absence of osteointegration and tension forces at the prosthesis/bone interface. Further investigation will be necessary to improve surface and design to increase radiological results in long-term follow-up. Additional surveys are required to improve indications, surgical approach and intraoperative control of correct component positioning.

Adult↗

Micromotion of the Souter-Strathclyde total elbow prosthesis in patients with rheumatoid arthritis 21 elbows followed for 2 years.

21 elbows in 18 patients with rheumatoid arthritis were treated with a Souter-Strathclyde total elbow prosthesis. 18 elbows were included in a radiostereometry (RSA) study. The aim of this clinical RSA study was to assess the three-dimensional micromotion pattern of the Souter-Strathclyde prosthesis, and thereby gain insight in the aseptic loosening process of this prosthesis. Implants were defined as at risk of aseptic loosening when the translation rate during the second postoperative year was more than 0.4 mm along one or more coordinate axes and/or the rate of rotation was more than 1 degrees about one or more coordinate axes. Clinical examination revealed an increase in the range of motion and a marked reduction in pain. The RSA showed that 8 of 18 humeral components were at risk of aseptic loosening, although no signs of such loosening-defined as a complete radiolucent line of 2 mm or more-were found on the plain radiographs. In 7 humeral components, an anterior tilt about the transverse axis was seen that resulted in an anterior translation of the proximal tip and a posterior translation of the component's trochlea. Long-term studies of the Souter-Strathclyde prosthesis, have shown that this rotation is a specific pattern of failure in some implants. None of the ulnar components was at risk for aseptic loosening. Improvements in fixation of the Souter-Strathclyde total elbow arthroplasty should focus on the humeral component. At present, the lateral flange of the implant is enlarged to improve rotational stability about the transverse and longitudinal axes. The effect of this change in design on micromotion of the Souter-Strathclyde total elbow prosthesis will be studied in a randomized RSA study comparing the new design to the existing one.

Aged↗

The Phenix expandable prosthesis: early American experience.

One of the major dilemmas in limb preservation in skeletally immature children involves the ability to maintain leg length equality. Many attempts have been made to design a prosthesis that could be expanded easily either nonoperatively or through a minor surgical procedure. Most of these designs have had mechanical difficulty or the lengthening procedure becomes a major surgical endeavor. The Phenix technology has been used in France for several years. The basic principle involves storage of energy in a spring which is maintained compressed by an original locking system. Once implanted, prosthetic lengthening is achieved via exposure to an external electromagnetic field that pilots the locking system and allows controlled release of the spring energy. Seven Phenix prostheses have been implanted in six patients. All patients had been treated for Stage II-B osteosarcoma. Six of the seven prostheses were implanted during revision procedures in salvage situations; one prosthesis was implanted during an index procedure. The surgical procedures were completed without complications. One patient sustained a fracture of the prosthesis in a fall and had an infection develop after implantation of the second prosthesis. Twenty-one expansions have been performed in six patients (mean lengthening at each procedure, 8 mm). There were no acute complications attributable to the lengthening procedure. Prosthetic expansions required an average of 20 to 30 seconds and were accompanied by very mild discomfort, if any. Most patients were given an oral analgesic either before or during the lengthening procedure. The Phenix prosthesis shows promise in handling the difficult problem of limb preservation in a growing child. Additional investigation is underway regarding limb lengthening and other dynamic applications.

Administration, Oral↗

Safety and effectiveness of a new saline filled testicular prosthesis.

PURPOSE: Testicular prostheses have been used for 50 years to replace missing or removed testes. In 1995 the manufacture of the silicone gel filled testis prosthesis in the United States was discontinued because of concern about the safety profiles of other implants. We assessed the safety and effectiveness of a new, saline filled implant for testicular replacement. MATERIALS AND METHODS: This open label, multicenter, prospective, case controlled clinical trial was done at 18 American tertiary referral centers. Adult and pediatric male patients missing 1 or 2 testes and without evidence of active malignancy or rheumatological disease were enrolled. All patients underwent formal rheumatological and urological evaluation prior to and after prosthesis placement. Main outcome measures were prosthesis safety assessed by adverse events and effectiveness assessed by changes in testis dimension. Secondary outcome measures were quality of life assessments with 3 validated instruments. All patients were followed a minimum of 1 year in this 5-year study. RESULTS: Postoperative adverse events observed in 19% of 149 patients included device related discomfort or pain in 3%, scrotal edema in 1.3%, infection in 1.3%, extrusion in 2.6%, deflation in 0.7% and pulmonary emboli in 0.7%. No patient reported rheumatological symptoms at 1 year. Testis dimensions were significantly increased in patients missing a testis at baseline (p <0.001). Subjective assessment of testicular appearance was significantly improved (p <0.001) and scores were stable or significantly improved in 2 of 3 quality of life instruments. CONCLUSIONS: At short-term followup a new, saline filled testis prosthesis appears safe and well tolerated. Importantly validated self-esteem measures also suggest improvement in quality of life after prosthesis placement.

Adolescent↗

Allograft-prosthesis composite for revision of catastrophic failure of total elbow arthroplasty.

BACKGROUND: Revision of a failed total elbow arthroplasty is a challenging procedure, often associated with bone deficiency. The purpose of this investigation was to review our experience with a composite allograft-implant reconstruction for patients with a failed total elbow arthroplasty. METHODS: Thirteen patients (thirteen elbows) in whom a total elbow arthroplasty had failed, primarily as a result of loosening of the humeral or ulnar component, were operated on with use of an allograft-prosthesis composite; the composite was placed on the humeral side in four of these patients and on the ulnar side in nine. The delay between the last total elbow arthroplasty and the allograft-prosthesis-composite procedure averaged eight years. RESULTS: At an average of forty-two months after the revision, the Mayo Elbow Performance Score was excellent for four elbows, good for three, fair for one, and poor for five. Nine of the thirteen patients had no or only slight pain in the elbow. The mean arc of flexion was 97 degrees, with an average of 28 degrees (range, 0 degrees to 60 degrees ) of extension to 125 degrees (range, 100 degrees to 140 degrees ) of flexion. There were seven complications affecting seven elbows, and five of the seven required a revision procedure. Deep infection developed in four elbows, and the allograft-prosthesis composite had to be removed from three. Two nonunions occurred at the allograft-humeral junction. CONCLUSIONS: An allograft-prosthesis composite can be a valuable option in selected patients with a failed total elbow arthroplasty with massive bone loss. The union and implant survival rates are high. Deep infection remains the main complication. Hence, we recommend the pursuit of other revision options, such as strut graft reconstruction, whenever possible before resorting to the use of an allograft-prosthesis composite in the surgical treatment of a failed total elbow arthroplasty with massive bone loss.

Adult↗

CarboMedics mechanical prosthesis: performance at eight years.

BACKGROUND AND AIM OF THE STUDY: The bileaflet St. Jude Medical mechanical prosthesis has been implanted for over 20 years. The purpose of this study was to evaluate the clinical performance of the bileaflet CarboMedics (CM) prosthesis, which was introduced in 1986. METHODS: The CM prosthesis was implanted in 1,258 patients (709 males, 549 females; mean age 60.9 +/- 12.3 years) between 1989 and 1997. The prosthesis distribution was aortic valve replacement (AVR) 613; mitral valve replacement (MVR) 447; and multiple replacement (MR) 231. Coronary artery bypass (CAB) was performed in 334 (26.6%) patients; previous procedures had been performed in 346 (27.5%). The age distribution was <60 years (n = 527), 61-70 years (n = 424) and >70 years (n = 307). Risk factors assessed were age or age groups, gender, CAB, previous surgery, rhythm, valve position, status and NYHA functional class. The total follow up was 4,765.0 patient-years (pt-yr), and was 98.4% complete. RESULTS: The early mortality rate was 5.6% (AVR 4.8%, MVR 3.7%, MR 11.5%). The late mortality rate was 3.7%/pt-yr (n = 174), and valve-related mortality 1.1%/pt-yr (n = 50). The total thromboembolism (TE) rate was 4.1%/pt-yr (n = 195) (p = NS by valve position); the major TE rate was 1.9%/pt-yr and fatal TE rate 0.31%/pt-yr (n = 15). The valve thrombosis rate was 0.31%/pt-yr (n = 15; 11 MVR, four MR). The fatal thrombosis rate was 0.06%/pt-yr (n = 3; two MVR, one MR). The hemorrhage rate was 2.7%/pt-yr (n = 128) and fatal hemorrhage rate 0.4%/pt-yr (n = 20). The reoperation rate was 1.0%/pt-yr (n = 46), fatal 0.1%/pt-yr (n = 5). The actuarial freedom from overall TE at eight years was 77.3 +/- 2.8%; major TE 88.5 +/- 1.6%, and hemorrhage 76.4 +/- 3.2% (all p = NS by valve position). There were no independent predictors of overall TE and TE exclusion of early events. The only predictor for TE major was status (emergency > urgent > elective). The actuarial freedom from valve-related mortality at eight years was 91.4 +/- 1.8% (p = NS by position) (actual freedom 93.0 +/- 1.3%). The actuarial freedom from valve-related reoperation was 91.1 +/- 2.4% (p <0.05; AVR > MVR and MR, MVR > MR) (actual freedom 92.2 +/- 2.7%). Overall survival rate at eight years was 68.2 +/- 2.3% (p <0.05; AVR > MVR and MR, MVR > MR). CONCLUSION: The clinical performance of the CarboMedics mechanical prosthesis is satisfactory when implanted in the mitral, aortic and multiple positions.

Aged↗

Mechanical reliability and safety of, and patient satisfaction with the Ambicor inflatable penile prosthesis: results of a 2 center study.

PURPOSE: We reviewed the experience with the 2-piece Ambicor penile prosthesis (American Medical Systems, Minnetonka, Minnesota) at 2 medical centers to investigate its mechanical reliability and complication rates as well as patient and partner satisfaction with the device. MATERIALS AND METHODS: From 1995 through 1999, 131 men underwent implantation of an Ambicor penile prosthesis at 2 medical centers. We performed a 3-part study consisting of a retrospective clinical record review, mailed patient and partner questionnaire, and mailed modified patient and partner Erectile Dysfunction Inventory of Treatment Satisfaction questionnaire. Mean followup was 43.4 months (range 12 to 73). RESULTS: All 131 men had a history consistent with an organic etiology of erectile dysfunction, including vascular disease in 62%, radical retropubic prostatectomy in 17%, Peyronie's disease in 15%, neophallus construction in 4% and radical pelvic surgery in 2%. Mean patient age was 56.8 years (range 22 to 76) at implantation. Overall there were complications in 10 cases (7.6%), including infection, hematoma and mechanical failure in 6 (4.6%), 1 (0.7%) and 3 (2.3%), respectively. A total of 112 men (85%) and 91 partners completed the questionnaire. All patient respondents still had an Ambicor prosthesis implanted and 96.4% had erection suitable for coitus. Overall patient and partner satisfaction was 96.4% and 91.2%, respectively. Of the respondents 92.9% of patients and 90.1% of partners would recommend the device to others. Of the 85 men (65%) and 46 partners who completed the modified Erectile Dysfunction Inventory of Treatment Satisfaction survey 90.6% and 82.6%, respectively, were satisfied or very satisfied overall with the penile prosthesis. CONCLUSIONS: The Ambicor penile prosthesis is associated with a low complication rate and reliable mechanical function. High satisfaction was reported by patients and partners.

Adult↗

[A revision prosthesis for the hip joint].

Following loosening of total hip prostheses increasing bone resorption occurs around the prosthesis, which can lead to extensive bony defects. In this paper a revision prosthesis for the femur is presented, which is fixed in the distal marrow cavity without cement, bridging the damaged prosthesis bed and stabilizing the femur. Vigorous bony regeneration begins in the resorption defects, which makes good the loss of bone substance. The revision prosthesis described for the cup is also implanted without cement. It allows additional fixation with screws and also onlay grafting, so that even when the acetabulum is badly damaged it is possible to change the prosthesis to obtain a good functional result and also allow recovery of the bone.

Acetabulum↗

[Dynamic obstruction of the left ventricular outflow tract by prosthesis dysfunction].

We report on a case of dynamic left ventricular (LV) outflow tract obstruction combined with a prosthetic valve dysfunction 13 years following mitral valve replacement with a Hancock bioprosthesis in a 46-year-old patient. Previously, repeated echocardiographic controls had been performed at regular intervals and the prosthesis had been found to be oversized and seated in abnormal position, with projection of the struts into the LV outflow tract. Moreover, a mild chronic LV outflow tract obstruction had been diagnosed upon intermittent findings of relatively high velocity in the outflow tract. Clinically, however, the patient had been stable and the function of the prosthesis had been good. With the onset of the mitral regurgitation due to prosthesis failure, a dynamic obstruction to LV outflow occurred, with severe narrowing of the LV outflow tract by a strut of the bioprosthesis during systole. Subsequently, a low cardiac output syndrome developed. The patient was referred for a mitral valve reoperation. The valve was replaced with a Sorin Bileaflet Carbon prosthesis. On the setting of a mild chronic LV outflow obstruction due to the oversized prosthesis and its abnormal position, hypercontractile cardiac function as a result of mitral regurgitation may have caused the dynamic and symptomatic LV outflow tract obstruction.

Bioprosthesis↗

[The inflatable penile prosthesis. Experiences apropos of 58 implants].

Prosthetic surgery for impotence has been transformed by the development of inflatable prostheses in the place of older semirigid models. Despite the popularity of this new technique, it raises certain questions concerning the functional results and complications of this surgery, which have only occasionally been studied concomitantly in the literature. The sexuality of patients has generally been evaluated on the basis of answers to a questionnaire sent to the patients. This study reports our experience, compared to the data in the literature, based on 58 insertions of inflatable prosthesis between October 1987 and October 1991. After rigorous patient selection and a mean follow-up of 30 months, the surgeon evaluated the objective results (mechanical functioning of the prosthesis, complications) and subjective results (sexuality) in 51 patients. 69.4% of patients presented an anomaly of prosthesis function, 10.3% developed an infection of the prosthesis, 34.5% required removal of the prosthesis, 59% declared that they were satisfied sexually and sexual activity was restored in 55%. This study therefore appears to contradict the optimistic data reported in the literature.

Adult↗

Custom-made segmental femoral replacement prosthesis in revision total hip arthroplasty.

Patients who present with failed total hip arthroplasty and significant proximal femoral bone loss pose a challenging reconstructive problem. When the integrity of the host proximal femur can be salvaged with cortical strut grafts, conventional long-stem femoral components can be used. If there is massive proximal femoral bone loss, hip salvage can be accomplished with a proximal femoral replacement prosthesis or an allograft-prosthesis composite. Although our early results with a proximal femoral replacement prosthesis were good, long-term results reveal a high rate of dislocation and acetabular component loosening, with an overall survivorship of 73% at 11 years. We have, therefore, limited the use of a proximal femoral replacement prosthesis to the elderly and inactive patient. We are encouraged by the preliminary results of total hip arthroplasty with a second-generation, modular, porous-coated, proximal femoral replacement prosthesis. Longer follow-up is required to determine whether these design modifications improve the results of this type of reconstructive procedure in revision total hip arthroplasty.

Adult↗

Intermediate term assessment of the reliability, function and patient satisfaction with the AMS700 Ultrex penile prosthesis.

PURPOSE: The AMS700 Ultrex penile prosthesis is an example of the design changes that penile prostheses have undergone to improve mechanical reliability. Few studies have reviewed an overall experience with the AMS700 Ultrex prosthesis. We review patient outcomes, surgical complications, and Ultrex cylinder intermediate term mechanical reliability and function. MATERIALS AND METHODS: Between March 1990 and November 1994, 145 patients 32 to 79 years old (mean age 58) underwent insertion of an AMS700 Ultrex penile prosthesis. At a followup of 6 to 62 months (mean 42) patients were evaluated with a retrospective clinical record review, and patient and partner questionnaires. RESULTS: From the clinical record review of 145 patients our malfunction, reoperation, infection, erosion, major complication and minor complication rates were 8, 13, 2, 3, 13 and 7%, respectively. Patient responses to our questionnaire showed that 85% were satisfied overall, 85% had durable and reliable implant function, 86% had a sustained level of satisfaction with the implant and 83% remained satisfied after a revision for malfunction. Overall, partner satisfaction with the implant was 76%, and 42% reported maintenance of a good or improved nonsexual relationship after prosthesis implantation. CONCLUSIONS: Our data demonstrate the intermediate term mechanical reliability and function of the AMS700 Ultrex penile prosthesis, and high patient and partner satisfaction with this implant.

Adult↗

Finite element analysis study of the effect of superstructure material on stress distribution in an implant-supported fixed prosthesis.

This study used three-dimensional finite element analysis to investigate the effect of three different occlusal surface materials (resin, resin composite, and porcelain) and four different framework materials (gold, silver-palladium, cobalt-chromium, titanium alloys) on the stress distribution in a six-implant-supported mandibular fixed prosthesis and surrounding bone. A total of 172 N vertical load was distributed over the entire occlusal surface of the finite element model. Generated stress values were calculated in the occlusal surface material, framework, prosthesis retaining screws, implants, and surrounding cortical and spongy bones. The results obtained demonstrated that using a prosthesis superstructure material with a lower elastic modulus (1) did not lead to substantial differences in stress patterns nor in values at the cortical and spongy bones surrounding the implants; and (2) concentrated stresses in the retaining screws for the prosthesis and thus increased the potential risk of prosthesis failure. For the single loading condition investigated, the optimal combination of materials was found to be cobalt-chromium for the framework and porcelain for the occlusal surface.

Acrylic Resins↗

Multi-institutional assessment of the Provox 2 voice prosthesis.

OBJECTIVES: To verify the initial results of a new anterograde replacement method of the second-generation indwelling Provox voice prosthesis, Provox 2 (Atos Medical AB, Hörby, Sweden), and to determine its device life. DESIGN: Nonrandomized, multi-institutional, controlled clinical trial. SETTING: Four academic hospitals and/or comprehensive cancer centers in The Netherlands. PATIENTS: Two hundred thirty-nine consecutive patients who had undergone laryngectomy and were visiting the outpatient clinic for replacement of their voice prosthesis. INTERVENTION: Anterograde replacement of the Provox 2 voice prosthesis. MAIN OUTCOME MEASURES: Evaluation of ease of use by the medical professional and appreciation by the patients, by means of structured questionnaires; comparison of device life between the original Provox and the new Provox 2 voice prosthesis in a subset of patients. RESULTS: Voice prostheses replaced were Provox (n = 188), Groningen (Medin, Groningen, The Netherlands) (n = 47), and Nijdam (Medin) (n = 4). Anterograde replacement of Provox 2 was always possible. The new anterograde method was preferred by the medical professionals in 97.1% of cases and by 93.7% of the patients, who reported significantly reduced discomfort (P<.001). There was no significant difference in device life between Provox and Provox 2 (median, 125.5 and 104 days, respectively). In 57.5% of patients, the Provox 2 device life was shorter and in 42.5% it was longer (sign test, P = .09). CONCLUSIONS: The results of the initial study concerning ease of use for the medical professionals and decreased discomfort for the patients of the new anterograde replacement procedure of the Provox 2 prosthesis were confirmed. The device life of Provox and that of Provox 2 were comparable, despite the alterations needed to optimize the Provox 2 prosthesis for the anterograde procedure.

Adult↗

Artificial larynx prosthesis: comparative clinical evaluation.

The work pioneered by Drs. Singer and Blom established the clinical feasibility of controlled tracheoesophageal fistula for generation of fluent esophageal speech. There have been numerous practical difficulties that have been encountered with the use of voice prosthesis. Problems encountered are: extrusion, speech initiation delay, leakage around the prosthesis, stoma obstruction, and low volume output. A second generation laryngeal prosthesis is introduced for comparison. Its design incorporates features that will significantly improve the clinical problems encountered; extrusion is minimized; and the new prosthesis allows for one size to fit all patients. A clinical trial was established to directly compare the artificial speech generated by the currently existing laryngeal prosthesis. Each laryngectomy patient was fitted with three different devices and the resulting speech was evaluated. Video recordings of patients are presented to illustrate the type of speech produced by each device. Comparisons of intelligibility, fluency, volume, and patient preference are made. Results indicate that a significant variation in the speech obtained is critically dependent on the choice of prosthesis.

Consumer Behavior↗

Immediate breast reconstruction by prosthesis: a safe technique for extensive intraductal and microinvasive carcinomas.

BACKGROUND: Immediate breast reconstruction (IBR) by prosthesis is frequently proposed after mastectomy. However, due to the morbidity of this operation, especially the early implant removal rate, its indications remain controversial. METHODS: We have performed 141 IBR by prosthesis (saline or gel-filled implant, tissue expander) in a homogeneous population of patients with extensive intraductal or microinvasive carcinoma, diagnosed after an initial local excision. This prospective study was designed to assess the feasibility and morbidity of IBR for an "ideal" population, allowing wide cutaneous preservation, without preoperative or postoperative treatment. RESULTS: The early prosthesis removal rate (< 2 months) was 0.7%, with only 2.1% of early surgical revisions and 3% of lymphoceles. Cutaneous complications (5%) were significantly correlated with the type of incision. Cosmetic results at 1 year were good or very good in 66% of cases, similar to the percentage observed after delayed reconstruction by prosthesis. CONCLUSIONS: In this selected population, IBR by prosthesis did not induce any additional morbidity compared with mastectomy without reconstruction. IBR by prosthesis can be systematically proposed in cases of extensive intraductal or microinvasive carcinoma.

Breast Implants↗

Peritoneal regeneration after implant of a composite prosthesis in the abdominal wall.

Prosthetic materials currently used to repair abdominal wall defects occasionally must be placed in direct contact with the visceral peritoneum. The prosthesis-peritoneum interface is the site of several possible problems, including the formation of adhesions and erosion of the intestinal loops, which may lead to the formation of fistulas. This investigation was designed to compare the behavior of two prosthetic biomaterials in composite form at the level of the peritoneum. Defects (7 x 5 cm) were created in the abdominal wall of 18 white New Zealand rabbits weighing approximately 2500 g. The defects (involving aponeurotic and muscular planes and the parietal peritoneum) were repaired with polypropylene (PL) + ePTFE (Preclude dura substitute) or Parietex composite (PC) prostheses. The prostheses were secured to the edges of the defect by continuous PL sutures interrupted at the corners of the implant. Three study groups were established according to the type of implant: group I (n = 6) (controls)--PL; group II (n = 6)--PL + ePTFE; and group III (n = 6)--PC. The animals were sacrificed 14 days after implant, and the prostheses were examined by light microscopy and scanning electron microscopy (SEM). The formation of adhesions at the prosthesis-visceral peritoneum interface were quantified according to a protocol previously described by us. The biomechanical resistance of the implant was evaluated using strips comprising prosthetic material and anchorage tissue. The Mann-Whitney U-test was used to compare data corresponding to each group. There was no postimplant mortality. No infection or rejection of the prosthesis was observed in any of the animals. Firm adhesions were detected in the PL implants, whereas in the PL + ePTFE and PC implants the adhesions were loose. The mean prosthetic surface areas covered by adhesions were 7.67, 0.10 and 0.19 cm2 for groups I, II, and III, respectively, showing a significant difference between values corresponding to groups I and II and to groups I and III (p < 0.05). Comparison of values recorded for groups II and III yielded no significant difference (p > 0.05). In groups II and III, the neoperitoneum was homogeneous and composed of organized and vascularized connective tissue covered by a mesoendothelium that was interrupted by accumulations of fibroblasts and white blood cells. In contrast, a disorganized neoperitoneum of rough texture was observed in the group I specimens. At times, areas of hemorrhage and necrosis corresponding to the sites of adhesion formation could be observed. Resistance to traction of composite implants (mean +/- SD: 15.72 +/- 1.32 and 15.89 +/- 2.73) was similar to that of the PL implants (15.03 +/- 2.92) (Mann-Whitney U-test, p < 0.05). It may be concluded that (1) composite prostheses show optimum behavior in terms of adhesion formation at the prosthesis-visceral peritoneum interface; (2) the neoperitoneum formed after the implant of a composite prosthesis almost physically and functionally replaces the normal peritoneum; (3) a significantly greater degree of peritoneal regeneration is achieved after implant of a PC prosthesis; and (4) there was no significant difference regarding biomechanical resistance between PL prostheses and PL + ePTFE and Parietex composites.

Abdominal Muscles↗

Women's satisfaction with partners' penile implant. Inflatable vs noninflatable prosthesis.

We evaluated 49 women whose sexual partners were organically impotent and subsequently received either an inflatable or noninflatable penile prosthesis. The women comprised three groups, based on the type of prostheses their partners had received: inflatable (n = 34), noninflatable (n = 11), and a double implant group (n = 4). The comparisons made were (1) dimensions of sexual satisfaction, (2) emotional stability, (3) satisfaction with the prosthesis, and (4) relationship changes. Two special questionnaires and the Derogatis Sexual Functioning Inventory were utilized in this evaluation. Women in the inflatable prosthesis group were found to be significantly more satisfied with the quality of their sexual relations and with their partner's prosthesis than were the women in the noninflatable prosthesis group. There apparently is a general advantage to women whose partners have received an inflatable prosthesis compared with the noninflatable alternatives.

Adult↗