Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31Linked to original sources

Zone electrophoresis separation of perfluorocarboxylic acids on a chip with conductivity detection.

Perfluorinated carboxylic acids (PFCAs), amphiphiles of anthropogenic origin, are spread worldwide throughout the environment. This work deals with their zone electrophoresis (ZE) separation on a chip with coupled columns and integrated conductivity detection. Analogies with the electrophoretic behavior of PFCAs and fatty acids were employed in a search for electrolyte conditions suitable for their separation. ZE separations in the water-ethanol electrolyte systems, based on differences in the ionic mobilities of the anions of PFCAs, provided favorable resolution and detection conditions of the homologues containing up to 10 carbon atoms in the alkyl chain. Concentration limits of detection of 0.3-6.5 micromol/L were attained for PFCAs (loaded by a 900 nL volume sample injection channel of the chip) under these separation conditions. The material of which the chip was made [poly(methylmethacrylate)] restricted its use in investigations of the separations of higher PFCA homologues as it was damaged by ethanolic and/or methanolic background electrolyte solutions required in experiments with these amphiphilic compounds.

Journal Article↗

Generation of bioreagents for protein chips.

Protein microarrays have the potential to dramatically increase the throughput of proteomic analysis. Protein expression profiling chips with distinct spots of immobilized protein capture agents will allow the simultaneous measurement of hundreds to thousands of proteins from one sample. In contrast to DNA chips, for which the capture probes are easily designed and synthesized, the development of content for protein biochips is a long and laborious process. Careful consideration must be given to the specificities desired, the format of the assay, and the requirements of the capture agents, as well as to process optimization to minimize development time and cost. Monoclonal antibodies have been the prime choice as protein capture agents for the majority of protein chips developed to date. New technologies for the production of protein capture agents are more amenable to automation than traditional monoclonal antibody production and therefore carry the promise for industrialization.

Affinity Labels↗

Self-assembling protein arrays on DNA chips by auto-labeling fusion proteins with a single DNA address.

The high-throughput deposition of recombinant proteins on chips, beads or biosensor devices would be greatly facilitated by the implementation of self-assembly concepts. DNA-directed immobilization via conjugation of proteins to an oligonucleotide would be preeminently suited for this purpose. Here, we present a unique method to attach a single DNA address to proteins in one step during the purification from the E. coli lysate by fusion to human O6-alkylguanine-DNA-alkyltransferase (SNAP-tag) and the Avitag. Use of the conjugates in converting a DNA chip into a protein chip by self assembly is demonstrated.

Base Sequence↗

Diagnosis of congenital disorders of glycosylation type-I using protein chip technology.

A method for the diagnosis of the congenital disorders of glycosylation type I (CDG-I) by SELDI-TOF-MS of serum transferrin immunocaptured on protein chip arrays is described. The underglycosylation of glycoproteins in CDG-I produces glycoforms of transferrin with masses lower than that of the normal fully glycosylated transferrin. Immobilisation of antitransferrin antibodies on reactive-surface protein chip arrays (RS100) selectively enriched transferrin by at least 100-fold and allowed the detection of patterns of transferrin glycoforms by SELDI-TOF-MS using approximately 0.3 microL of serum/plasma. Abnormal patterns of immunocaptured transferrin were detected in patients with known defects in glycosylation (CDG-Ia, CDG-Ib, CDG-Ic, CDG-If and CDG-Ih) and in patients in whom the basic defect has not yet been identified (CDG-Ix). The correction of the N-glycosylation defect in a patient with CDG-Ib after mannose therapy was readily detected. A patient who had an abnormal transferrin profile by IEF but a normal profile by SELDI-TOF-MS analysis was shown to have an amino acid polymorphism by sequencing transferrin by quadrupole-TOF MS. Complete agreement was obtained between analysis of immunocaptured transferrin by SELDI-TOF-MS and the IEF profile of transferrin, the clinical severity of the disease and the levels of aspartylglucosaminidase activity (a surrogate marker for the diagnosis of CDG-I). SELDI-TOF-MS of transferrin immunocaptured on protein chip arrays is a highly sensitive diagnostic method for CDG-I, which could be fully automated using microtitre plates and robotics.

Amino Acid Sequence↗

Quantitation of midazolam in human plasma by automated chip-based infusion nanoelectrospray tandem mass spectrometry.

An automated chip-based infusion nanoelectrospray ionization (nanoESI) platform was used to demonstrate reproducible quantitation of drug molecules from biological matrices. Three sample preparation strategies were explored including protein precipitation of plasma with acetonitrile, de-salting of the plasma, and a combination of protein precipitation with subsequent de-salting of the dried and reconstituted extract. The best results were obtained when fortified human plasma samples containing midazolam were precipitated with acetonitrile containing alprazolam as the internal standard (IS). The supernatant was concentrated to dryness, reconstituted in aqueous acid, and de-salted by automated reversed-phase solid-phase extraction (SPE) prior to infusion nanoESI-MS/MS. Analyses employed a triple quadrupole mass spectrometer operated in selected reaction monitoring (SRM) mode. Each sample was infused for approximately 10 s and the resulting ion current profiles were integrated. Area ratios were used for regression analysis of standard samples (1.5-500 ng/mL). Quality control samples (3, 250, and 400 ng/mL) in five replicates from three different analysis days demonstrated intra-assay precision (< or =16%), inter-assay precision (< or =5%), and overall accuracy (+/-9% deviation). Infusion reproducibility of the assay was established by analyzing extracts after storage for 24 h at ambient temperature. Control plasma samples from six different sources probed the potential utility of this technique for the analysis of clinical samples. At the lower limit of quantitation (LLQ), variability and mean overall accuracy were < or =13% CV and +/-3% deviation, respectively, while at the upper limit of quantitation (ULQ) variability and mean overall accuracy were < or =9% CV and +/-9% deviation, respectively. Inter-chip variability was established by determining standard sample extracts across five different chips (< or =12% CV). Throughput for the assay was 55 s per sample, although this time may be shortened to 40 s per sample with recent improvements in the automated nanoESI system. No contamination or carryover was observed using this promising automated nanoESI-MS/MS platform.

Automation↗

The combination of liquid chromatography/tandem mass spectrometry and chip-based infusion for improved screening and characterization of drug metabolites.

An approach has been developed for drug metabolism studies of non-radiolabeled compounds using on-line liquid chromatography/tandem mass spectrometry (LC/MS/MS) combined with chip-based infusion following fraction collection. The potential of this approach, which improves the data quality compared with only LC/MS analysis, has been investigated for the analysis of in vitro metabolites of tolcapone and talinolol, two compounds with well-characterized metabolism. The information-dependent LC/MS/MS analysis enables the characterization of the major metabolites while the chip-based infusion is used to obtain good product ion spectra for lower level metabolites, to generate complementary MS information on potential metabolites detected in the LC/MS trace, or to screen for unexpected metabolites. Fractions from the chromatographic analysis are collected in 20 second steps, into a 96-well plate. The fractions of interest can be re-analyzed with chip-based infusion on a variety of mass spectrometers including triple quadrupole linear ion trap (QqLIT or Q TRAP) and QqTOF systems. Acquiring data for several minutes using multi-channel acquisition (MCA), or signal averaging while infusing the fractions at approximately 200 nL/min, permits about a 50 times gain in sensitivity (signal-to-noise) in MS/MS mode. A 5-10 microL sample fraction can be infused for more than 30 min allowing the time to perform various MS experiments such as MS(n), precursor ion or neutral loss scans and accurate mass measurement, all in either positive or negative mode. Through fraction collection and infusion, a significant gain in data quality is obtained along with a time-saving benefit, because the original sample needs neither to be re-analyzed by re-injection nor to be pre-concentrated. Therefore, a novel hydroxylated talinolol metabolite could be characterized with only one injection.

Animals↗

Characterization of the surfaces generated by liposome binding to the modified dextran matrix of a surface plasmon resonance sensor chip.

The dextran matrix of a surface plasmon resonance (SPR) sensor chip modified with hydrophobic residues (BIAcore sensor chip L1) provides an ideal substrate for liposome adsorption. Liposomes of different lipid compositions are captured on the sensor chips by inserting these residues into the liposome membrane, thereby generating stable lipid surfaces. To gain a more detailed understanding of these surfaces, and to prove whether the liposomes stay on the matrix as single particles or form a continuous lipid layer by liposome fusion, we have investigated these materials, using atomic force microscopy (AFM) and fluorescence microscopy. Force measurements with AFM probes functionalized with bovine serum albumin (BSA) were employed to recognize liposome adsorption. Analysis of the maximal adhesive force and adhesion energy reveals a stronger interaction between BSA and the dextran matrix compared to the lipid-covered surfaces. Images generated using BSA-coated AFM tips indicated a complete and homogeneous coverage of the surface by phospholipid. Single liposomes could not be detected even at lower lipid concentrations, indicating that the liposomes fuse and form a lipid bilayer on the dextran matrix. Experiments with fluorescently labeled liposomes concurred with the AFM studies. Surfaces incubated with liposomes loaded with TRITC-labeled dextran showed no fluorescence, indicating a complete release of the encapsulated dye. In contrast, surfaces incubated with liposomes containing a fluorescently labeled lipid showed fluorescence.

Animals↗

Application of different surface plasmon resonance biosensor chips to monitor the interaction of the CaM-binding site of nitric oxide synthase I and calmodulin.

Surface plasmon resonance biosensors depend on modified gold surfaces to allow immobilization of proteins or peptides for interaction analysis. We investigated sensor chip surfaces that differ in the geometry of the immobilization matrix: two contain a three-dimensional coupling matrix and two have a surface with immobilization sites on a two-dimensional plane. Properties of sensor chips were compared by studying the interaction of calmodulin with a peptide representing the calmodulin-binding site of nitric oxide synthase I. Apparent K(D) values were determined by three different procedures in order to apply tests for self-consistency. At low surface densities (5-8 fmol/mm(2)) on three of the four tested surfaces, estimated K(D) values were within one order of magnitude and similar to the value found in solution (K(D) = 1-3 nM). When immobilization densities were increased by one to two orders of magnitude, apparent association rate constants were less distorted on a flat carboxymethylated surface than on dextran-coated sensor chips.

Amino Acid Sequence↗

Multiparametric sensor chips for chemosensitivity testing of sensitive and resistant tumor cells.

Many different assays have been developed for testing the chemosensitivity of tumor cells in vitro, usually based on a single biochemical or cellular parameter. A multiparametric test system has been developed that accommodates on a single chip numerous sensors for metabolic parameters, deltapH and deltapO2, as well as for morphological changes. The cells grow directly on the chips and can be continuously monitored online up to several days. The effects of various chemotherapeutic drugs on the metabolic profile of several tumor cell lines have been investigated. In colon carcinoma-derived LS174T cells, cytochalasin B markedly increased oxygen consumption while decreasing the rate of extracellular acidification. These effects, which reflect the biochemical action of cytochalasin B, were reversible on drug removal. In contrast, chloroacetaldehyde markedly reduced respiration, which recovered when the drug was removed. Primary breast cancer cells also responded to chloroacetaldehyde with a marked reduction in deltapO2, followed by a reduced rate of acidification. Comparing the metabolism of doxorubicin-sensitive and -resistant mouse sarcoma S180 cells, the rates of acidification and respiration were inhibited by doxorubicin only in the sensitive cells, whereas in the resistant cells oxygen consumption even increased. These examples demonstrate that this chip-based test system provides rapid and important information for assessing chemosensitivity of tumor cells.

Acetaldehyde↗

Phase II study of CHIP chemotherapy in advanced adenocarcinomas of the upper gastrointestinal tract.

Iproplatin (CHIP) is a second generation cisplatin analogue which has completed its Phase I trials. We studied the efficacy and toxicity of CHIP in 36 previously untreated patients with advanced upper gastrointestinal tract adenocarcinomas (GE junction, cardia, antrum and body of the stomach). The starting dose was 275 mg/m2; course were repeated on an every four week schedule. Thirty-five patients were evaluable for response. Three partial remissions (8.5%) [95% confidence limits 2.5-15%] were seen. Toxicity was tolerable and included mild myelosuppression and mild nausea and vomiting. Although well tolerated, in patients with gastric and GE junction adenocarcinomas, CHIP chemotherapy was not more and probably slightly less, effective than the parent analogue cisplatin.

Adenocarcinoma↗

Comparison of intestinal toxic effects of platinum complexes: cisplatin (CDDP), carboplatin (CBDCA), and iproplatin (CHIP).

The biochemical background of the intestinal side effects of cis-diammine-1,1-cyclobutane dicarboxylate platinum (II) (CBDCA) and cis-diisopropylamine-trans-dihydroxy-dichloro platinum (IV) (CHIP) was compared with those of cis-diamminedichloroplatinum (II) (CDDP). Biochemical investigations were carried out on mucosal cells isolated by a combined chemical-mechanical method from the total length of the small intestine. After treatment with single, equitoxic doses of Pt analogues, the activities of thymidine kinase (TK) EC 2.7.1.21, sucrase (SUC) EC 3.2.1.26, maltase (MAL) EC 3.2.1.20, and protein content showed dose-dependent decreases, whereas the activity of alkaline phosphatase (AP) EC 3.2.1.20 increased slightly. The nadir of enzyme activity changes occurred 24-48 h after treatment. For the regeneration of the mucosa more than 96 h was necessary. Of the platinum analogues studied, CHIP proved to be the most toxic to the small intestine. While the highest doses of CDDP and CBDCA (0.66 x LD50) caused significant but less than 50% decreases in TK, SUC, MAL, and protein content (PROT), the CHIP doses needed for 50% reduction were between 0.44-0.66 x LD50.

Alkaline Phosphatase↗

[Influence of raw material on storage behaviour of potato chips (author's transl)].

The influence of storage duration on the lipid and fatty acid content of potato tubers and on the concentration of volatile aroma substances in potato chips were studied. An increase in the unsaturated fatty acids of potato tubers was found during the first months of storage. The higher lipid content of early maturing varieties as compared with late maturing ones may be explained by decreased physiological maturity of these potatoes. Among the aroma substances the constituents hexanal, pentanal, and pentane are possible important indicators for the rancidity of potato chips. Relationships between differing storage conditions of chips and their reeping quality were indicated by volatile aroma substances, especially hexanal.

Chromatography, Gas↗

Difference of gene expression profiles between Barrett's esophagus and cardia intestinal metaplasia by gene chip.

The difference of gene expression profile changes in Barrett's esophagus (BE) and cardia intestinal metaplasia (CIM) epithelium was studied and the novel associated genes were screened in the early stage by cDNA microarray. The cDNA retro-transcribed from equal quantity mRNA from BE and CIM epithelial tissues were labeled with Cy3 and Cy5 fluorescence as probes. The mixed probe was hybridized with three pieces BiostarH-40s double dot human whole gene chip. The chips were scanned with a ScanArray 4000. The acquired images were analyzed using GenePix Pro 3.0 software. It was found a total of 141 genes were screened out that exhibited differentially expression more than 2 times in all three chips. It was identified that in gene expression profiles of BE, 74 genes were up-regulated and 67 down-regulated as compared with CIM. The comparison between the difference of gene expression profile changes in BE and CIM epithelia revealed that there existed the difference between BE and CIM at gene level. 141 genes with the expression more than two time were probably related to the occurrence and development of BE and the promotion or progress in adenocarcinoma.

Barrett Esophagus↗

Single nucleotide polymorphism analysis by chip-based hybridization and direct current electrical detection of gold-labeled DNA.

Single nucleotide polymorphism (SNP) analysis at the point of care requires a low cost detection technology that is capable of miniaturization, multiplexing, and high sensitivity. Direct current electrical detection (DCED) of DNA following nanoparticle labeling and silver enhancement is a promising candidate technology for point-of-care diagnostics. In this work we present, for the first time, SNP analysis in PCR products from patient samples using DCED, taking this platform technology a step closer to practical application. We developed a silane functionalized polymer for coating of biochip surfaces. This polymeric coating is stable under harsh conditions and has exceptionally high binding capacity. Allele-specific oligonucleotide probes were immobilized on chips coated with this polymer. Biotinylated PCR products of the human cholesteryl ester transfer protein gene from different patients were hybridized to the chips, labeled with gold nanoparticles, and autometallographically enhanced. The chips were scanned for DC electrical resistance by applying movable electrodes to the surface. Eighteen of nineteen patient samples were assigned the correct genotype. Our results demonstrate that SNP analysis of patient samples is feasible with DCED.

Affinity Labels↗

Posterolateral fusion using laminectomy bone chips in the treatment of lumbar spondylolisthesis.

We retrospectively reviewed the outcome of posterolateral fusion (PLF) in 136 patients with lumbar spondylolisthesis (LS), who had undergone posterior decompression laminectomy with foraminotomy and PLF using laminectomy bone chips as bone graft, with reduction of the slipped vertebra with transpedicle screws, between 1993 and 2003. Diagnosis of LS was confirmed by plain lumbar radiography, with computed tomography (CT) scan or magnetic resonance imaging (MRI) studies performed to confirm an associated condition, such as ruptured disc and spinal stenosis. The outcome of spinal fusion was good with 129 (94.85%) patients attaining solid fusion, while failed fusion was noted in seven (5.15%) patients. None of our patients complained of excessive postoperative wound pain. Additionally, no complications, such as wound infection, were encountered. Proper decortication of the posterior paravertebral gutters with an osteotome and removal of all soft tissues from the laminectomy bone chips are significant factors contributing to the successful outcome of the laminectomy bone chips in PLF. The fusion rate obtained with this type of autogenous bone graft is comparable to that of the iliac bone crest autogenous graft; hence, it is a good substitute for the iliac crest bone autogenous graft in performing PLF in treating lumbar spondylolisthesis.

Adolescent↗

Low volume amplification and sequencing of mitochondrial DNA on a chemically structured chip.

Low volume (LV) amplification (1 microL) of nuclear DNA (nucDNA) on a chemically structured chip is an appropriate and highly sensitive method to simultaneously amplify amelogenin and 15 forensically relevant short tandem repeats (STR). In this study, a combined method using on-chip LV amplification of mitochondrial DNA (mtDNA) and subsequent on-chip LV cycle sequencing was established to obtain a method, which is sensitive and robust enough to allow reliable analysis of DNA amounts representing the single cell level. All the necessary steps of the procedure--except for the purification of the sequencing products--were accomplished within the same final 2-microL reaction volume.

DNA Fingerprinting↗

Quantitative PCR based expression analysis on a nanoliter scale using polymer nano-well chips.

The analysis of gene expression is an essential element of functional genomics. Expression analysis is mainly based on DNA microarrays due to highly parallel readout and high throughput. Quantitative PCR (qPCR) based expression profiling is the gold standard for the precise monitoring of selected genes, and therefore used for validation of microarray data. Doing qPCR-based expression analysis in an array-like format can combine the higher sensitivity and accuracy of the qPCR methodology with a high data density at relatively low costs. This paper describes the development of an open-well based miniaturized platform for liquid PCR-based assays on the nanoliter scale using cost-effective polypropylene micro reactors (microPCR Chip). We show the quantification ability and reliability of qPCR in 200 nl with the microPCR chip down to 5 starting target molecules using TaqMan chemistry. An RNA expression analysis of four genes in mouse brain, liver and kidney tissues showed similar results in 200 nl as compared to standard 10 microl assays. The high sensitivity and quantification capability of the microPCR chip platform developed herein makes it a promising technology for performing high-throughput qPCR-based analysis in the nanoliter volume range.

Animals↗

Detergent-soaked HRP-chips: a new method for precise and effective delivery of small quantities of the tracer to nervous tissue.

We dissolved horseradish peroxidase (HRP) in a 5% aqueous detergent solution (Nonidet P-40) and dried it to a solid mass which was then fragmented into small chips of convenient size. These were applied to the cut or crushed oculomotor nerves of Xenopus laevis tadpoles. This method combines the advantages of solid HRP (high concentration) and the presence of a detergent (enhanced uptake). Moreover, as compared to chips of HRP alone, addition of the detergent facilitated the manipulation of the chips.

Animals↗