Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Cardiac Catheterization”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31Linked to original sources

Safety and efficacy of repeat transradial access for cardiac catheterization procedures.

To determine the safety and efficacy of repeat transradial cardiac catheterization, 1,362 consecutive transradial procedures were examined. Repeat transradial procedures were identified (group I, n = 73) and compared with index procedures (group II, n = 1,289). Baseline patient characteristics, procedure success rates (100% vs. 97.9%; P = NS), complication rates (0% vs. 0.08%; P = NS), and procedure times (23.9 +/- 27.3 min vs. 18.2 +/- 14.7 min; P = NS) were similar between groups. This study suggests that repeat transradial catheterization procedures can be performed safely and successfully in appropriately selected patients.

Aged↗

Abnormal vascular tone in infants and children with lung hypoplasia: Findings from cardiac catheterization and the response to chronic therapy.

OBJECTIVE: We describe four cases of chronic pulmonary hypertension in infants and children with chronic lung disease and pulmonary hypoplasia due to severe congenital diaphragmatic hernia (CDH) or congenital cystic adenomatoid malformation (CCAM). We report data from cardiac catheterization under various conditions: baseline respiratory support and room air, hyperoxic and inhaled nitric oxide challenge. We further report cardiac catheterization measures after chronic pulmonary vasodilator therapy with sildenafil alone or a combination of sildenafil and inhaled nitric oxide (three patients). DESIGN: Case series. SETTING: Tertiary academic center. PATIENTS: Infants and children ages 0-11 yrs with CDH (n = 3) or CCAM (n = 1) with evidence of chronic pulmonary hypertension by echocardiogram and cor pulmonale (n = 3). INTERVENTIONS: Catheterization and pulmonary vasodilator therapy. MEASUREMENTS AND MAIN RESULTS: Pulmonary vascular resistance, pulmonary arterial pressure, and changes in these measures were assessed. A 20% change in pulmonary vascular resistance was considered a clinically significant response. Ten catheterizations were performed in four patients. All patients had elevated pulmonary vascular resistance and pulmonary arterial pressures at initial catheterizations and significant vasodilation during inhaled nitric oxide. CONCLUSIONS: Chronic lung disease following pulmonary hypoplasia from CDH and CCAM is associated with abnormal pulmonary vascular tone in infants and children with evidence of chronic pulmonary hypertension. Chronic pulmonary vasodilator therapy may improve pulmonary vascular function and enhance lung growth in infants and children who are treated during their period of potential for rapid lung growth.

Cardiac Catheterization↗

[Effects of shuangshen ningxin capsule on mini-porcine myocardial ischemia model induced by thrombosis via cardiac catheterization intervention].

OBJECTIVE: To investigate the establishment of mini-porcine myocardial ischemia (MI) model induced by thrombosis via cardiac catheterization intervention, and observe the anti-MI action of Shuangshen Ningxin Capsule (SNC). METHODS: MI model of Chinese mini-porcine was established by injection of self-thrombus in left anterior descending coronary artery (LAD) with guiding catheter through carotid artery. The effect of SNC on MI was evaluated comprehensively by analyzing the parameters as coronary embolism, 30 dots surface mapping electrocardiogram and quantitative histology, etc. RESULTS: LAD in the model animals was basically embolized 6 days after modeling, showing increase of amplitude and dot of ST segment elevation. After being administered with SNC for 6 days, the self-thrombus blocked LAD was recanalized and the degree and extent of MI reduced. CONCLUSION: It is the first time to successfully establish MI model of Chinese mini-procine by thrombosis via cardiac catheterization intervention. SNC has anti-MI effect.

Animals↗

Cardiac catheterization in infants and children can be an outpatient procedure.

Many cardiac catheterization procedures in infants and children can be performed on an outpatient basis. This has been the practice in a pediatric hospital for 18 years. Over the last 12 years 1,355 of 2,133 catheterization procedures were performed on an outpatient basis. Excluding newborns, 45 percent of infants under 1 year of age having catheterization procedures were studied as outpatients. After age 1 year, 83 percent of the patients were studied as outpatients. Many of the patients admitted to the hospital would have been suitable for outpatient study. There were no significant complications related to the outpatient program. The main advantage would seem to be a reduction in anxiety concerning the test for children and their parents.

Ambulatory Care↗

[The role of cardiac catheterization for diagnosis and treatment of pulmonary hypertension].

The role of the cardiac catheterization for diagnosis and treatment of pulmonary hypertension (PH) is very important. When mean pulmonary artery pressure increased more than 25 mmHg, then PH is defined. But this is measured accurately only by the catheterization. And we can discriminate the etiology of PH clearly by pulmonary capillary wedge pressure (Ppcw) or intra-cardiac shunt (L to R) by blood oxygen saturation step-up, and both parameters are obtained by this method. The etiology of PH is diagnosed as left sided heart failure, if Ppcw is increased more than 13 mmHg. PH is produced by congenital heart disease (ASD, VSD, PDA etc.), when the oxygen saturation step-up is recognized. And PH is induced by any pulmonary disease or pulmonary thrombo-embolism or collagen disease or liver cirrhosis or PPH, if Ppcw is normal and no oxygen step-up is recognized.

Blood Pressure↗

Cardiac catheterization laboratories: what are their prospects for growth?

The volume of cardiac catheterizations performed has grown rapidly in recent years; interest in offering this modality is great. But planning for this service has become complex; new technologies will change patterns of use, while economic constraints may make profitability more difficult to achieve. Hospital CEOs at those institutions that do not presently have cath labs should carefully consider the level of demand and the effects of changes in reimbursement before proceeding with plans to offer this service.

Cardiac Catheterization↗

[Unusual complications of cardiac catheterization via the radial artery].

Use of the radial artery for cardiac catheterization has significantly reduced the incidence and severity of complications at the access site. Nevertheless, occasionally unusual complications or atypical responses to treatment are observed. We describe two cases: a radial artery pseudoaneurysm that was unresponsive to compression treatment and a foreign-body inflammatory reaction at the radial artery access site. The characteristics, development and treatment of the 2 cases are described, and the pathogenic mechanisms are discussed.

Aneurysm, False↗

The effects of transfemoral cardiac catheterization on limb blood flow in children.

Blood flow was measured with a mercury-in-rubber strain-gauge plethysmograph in the utilized and intact extremity during and 24 hours after uncomplicated (with no clinical signs of vascular insufficiency) percutaneous right and left cardiac catheterization in 20 children. In this group, there was a significant decrease of the flow in the utilized extremity after entry into the artery, with the flow returning to normal within 24 hours after the procedure. Flow was markedly reduced in the utilized extremity of a child who developed thrombosis of the femoral artery after catheterization. Seven additional children were studied one to four years after retrograde catheterization. In this group the flows in utilized and intact extremities were equal at rest and with reactive hyperemia. It is concluded that uncomplicated transfemoral percutaneous cardiac catheterization in children does not impair the blood flow in the limbs.

Adolescent↗

Evaluation of poly-N-acetyl glucosamine as a hemostatic agent in patients undergoing cardiac catheterization: a double-blind, randomized study.

BACKGROUND: This is the first blinded, randomized, placebo-controlled clinical trial to evaluate the efficacy of poly-N-acetyl glucosamine (p-GLcNAc) in improving hemostasis in patients undergoing cardiac catheterization. METHODS: Patients were randomly assigned to have either a placebo-treated (n = 17) or a p-GlcNAc-treated (n = 16) 3 x 3-cm patch topically placed at the femoral insertion site at the completion of their catheterization procedure with a mechanical pressure clamp applied over it. The amount of pressure was measured. RESULTS: Although the placebo group had slightly higher clamp pressure applied to the femoral arterial puncture site at the end of the catheterization procedure (189 +/- 47 vs. 149 +/- 49 mm Hg, p = 0.042), the time to effective hemostasis (16 +/- 7 vs. 10 +/- 3 minutes, p = 0.01) was decreased in the p-GlcNAc group by 37%. CONCLUSION: The application of p-GlcNAc patches improved hemostasis at the arterial puncture site in patients undergoing cardiac catheterization.

Acetylglucosamine↗

Endogenous biosynthesis of prostacyclin during cardiac catheterization and angiography in man.

The potent platelet inhibitory and vasodilator properties of prostacyclin suggest that levels of this substance may be of relevance to drug action and pathologic processes in the coronary vascular bed. Attempts to estimate the coronary secretion rate of prostacyclin have relied on measurements of metabolites obtained via cardiac catheter, usually as an adjunct to coronary angiography. To test the hypothesis that such procedures might themselves perturb endogenous biosynthesis of prostacyclin we used mass spectrometry to measure plasma levels of 6-keto-prostaglandin (PG) F1 alpha across the coronary vascular bed, as well as to assess the excretion of a major urinary metabolite, 2,3-dinor-6-keto-PGF1 alpha (PGI-M), in patients undergoing cardiac catheterization. PGI-M excretion increased variably from a median 100 to 205 pg/mg creatinine (p less than .01) during catheterization with angiography and remained elevated 2 to 4 hr after initiation of the procedure. However, cardiac catheterization without angiography also stimulated metabolite excretion, perhaps reflecting catheter-induced vascular trauma. The direct effect of radiocontrast media on vascular release of prostacyclin was indicated by increased PGI-M excretion in healthy volunteers administered intravenous radiocontrast and by studies of the canine coronary artery and jugular vein in vitro. Measurement of plasma 6-keto-PGF1 alpha after left heart catheterization showed that levels in aortic (21 +/- 8 pg/ml) and coronary sinus (14 +/- 2 pg/ml) blood were increased compared with peripheral venous levels (less than or equal to 4 + 1 pg/ml) determined before this procedure.(ABSTRACT TRUNCATED AT 250 WORDS)

6-Ketoprostaglandin F1 alpha↗

SCAI statement on ad hoc versus the separate performance of diagnostic cardiac catheterization and coronary intervention.

Coronary intervention may be combined with diagnostic cardiac catheterization or performed separately. In the early years of angioplasty, performing these procedures separately was standard practice. Gradually, ad hoc intervention (performing diagnostic angiography and coronary intervention within the same session) has become more common, largely because of its convenience for patients and efficiency for physicians. However, the safety and potential cost savings of this approach remain uncertain. Criteria for the appropriate use of ad hoc intervention have not been established. Ad hoc intervention is reasonable for many, but not appropriate for all patients and should not be considered standard therapy. This document updates an earlier review of this topic and provides suggestions for the use of ad hoc intervention as a routine strategy.

Angioplasty, Balloon, Coronary↗

Is noninvasive risk stratification sufficient, or should all patients undergo cardiac catheterization and angiography after a myocardial infarction?

From the foregoing discussion, it becomes apparent that although noninvasive risk stratification is a reasonable approach to assessment of patients following an uncomplicated myocardial infarction, the performance of early cardiac catheterization and angiography on nearly all such patients is not unreasonable and may in fact be the most practical approach. The basis for this rationalization may be summarized as follows: 1. Many subgroups will need early catheterization anyway a. Myocardial infarction complicated by recurrent ischemia, heart failure, or complex ventricular arrhythmias b. Patients receiving thrombolytic treatment c. "Young" patients (less than 50 years old?) d. "Older" patients (over ages 65 to 70?) in otherwise good medical condition e. Patients unable to exercise f. Patients with abnormal or inconclusive noninvasive test results (approximately 70 percent of patients) 2. Cardiac catheterization and angiography as a single test provides the two most powerful prognostic variables following myocardial infarction, namely, the extent of coronary artery disease and residual left ventricular function. This knowledge is reassuring to both physician and patient and allows for planning of optimal long-term management. 3. Certain limitations exist in noninvasive risk assessment strategies. 4. This approach need not be significantly more costly, if all tests are used wisely. The major risk inherent in the definition of the extent of coronary artery disease in all survivors of acute myocardial infarction might be the performance of unnecessary revascularization procedures (percutaneous transluminal coronary angioplasty or coronary bypass surgery). The burden rests with the individual clinician to (1) collect all useful and necessary data; (2) assess reliability and accuracy of various tests available at one's own institution; (3) avoid performing unnecessary and repetitive tests; (4) interpret the data in the proper context; and (5) counsel patients appropriately, correctly, and judiciously about their prognosis and therapeutic options. In this manner, all patients who might benefit appropriately from revascularization can be discovered early and offered this therapeutic option. Other patients can also be managed more appropriately; for example, those who are truly at very low risk (normal left ventricular function and either normal coronary arteries or "mild" coronary artery disease). However, it is most important to avoid unnecessary revascularization procedures. Although this discussion has focused on noninvasive and invasive testing following myocardial infarction, it is necessary to emphasize that comprehensive management of coronary artery disease and its complications should not be neglected in these patients; for example, control or amelioration of risk factors for coronary artery disease is mandatory in all these patients, and in their families as well.

Aged↗

Cardiac catheterization in infants through a venous cutdown sheath.

When percutaneous vascular access for cardiac catheterization of small infants fails, necessitating a cutdown approach, we cannulate the isolated vein (usually the great saphenous vein) with a guidewire, dilator, and sheath with subsequent introduction of the catheter through the indwelling sheath. We have used this technique in sixty-one infants without complications and recommend this modified sheath approach because of the following advantages: ease of introduction of the introducer set and catheter, the ability to change catheters quickly, elimination of distal vascular spasm, reduction of vascular trauma induced by catheter manipulation, prevention of backflow bleeding at the catheter entry site, and possible reduction of catheterization time.

Cardiac Catheterization↗

Prognostic value of ventricular arrhythmias associated with treadmill exercise testing in patients studied with cardiac catheterization for suspected ischemic heart disease.

The prognostic information provided by ventricular arrhythmias associated with treadmill exercise testing was evaluated in 1,293 consecutive nonsurgically treated patients undergoing an exercise test within 6 weeks of cardiac catheterization. The 236 patients with simple ventricular arrhythmias (at least one premature ventricular complex, but without paired complexes or ventricular tachycardia) had a higher prevalence of significant coronary artery disease (57 versus 44%), three vessel disease (31 versus 17%) and abnormal left ventricular function (43 versus 24%) than did patients without ventricular arrhythmias. Patients with paired complexes or ventricular tachycardia had an even higher prevalence of significant coronary artery disease (75%), three vessel disease (39%) and abnormal left ventricular function (54%). In the 620 patients with significant coronary artery disease, patients with paired complexes or ventricular tachycardia had a lower 3 year survival rate (75%) than did patients with simple ventricular arrhythmias (83%) and patients with no ventricular arrhythmias (90%). Ventricular arrhythmias were found to add independent prognostic information to the noninvasive evaluation, including history, physical examination, chest roentgenogram, electrocardiogram and other exercise test variables (p = 0.03). Ventricular arrhythmias made no independent contribution once the cardiac catheterization data were known. In patients without significant coronary artery disease, no relation between ventricular arrhythmias and survival was found.

Arrhythmias, Cardiac↗

Early mobilization after diagnostic cardiac catheterization with the use of a hemostatic bandage containing thrombin.

The aim of the present study was to assess the efficacy and safety of a thrombin-containing bandage for local hemostasis after femoral sheath removal in patients undergoing diagnostic cardiac catheterization. Forty-one patients undergoing diagnostic coronary angiography using a 6-F femoral sheath were included. The sheath was removed immediately after the procedure using the bandage according to a prespecified protocol. Mean compression time was 7.3+/-1.7 min and mean time from sheath removal to mobilization was 132+/-34 min. None of the patients suffered recurrent bleeding or any in-hospital and 7-day vascular complications. We conclude that in patients undergoing femoral-access diagnostic cardiac catheterization, the use of a hemostatic bandage containing thrombin was associated with short time to hemostasis with the ability for early patient mobilization without vascular complications.

Bandages↗

Nonsurgical closure of femoral pseudoaneurysms complicating cardiac catheterization and percutaneous transluminal coronary angioplasty.

OBJECTIVES: This study was performed to describe the initial experience and follow-up of ultrasound-guided compression of pseudoaneurysms in patients receiving systemic anticoagulant or antiplatelet therapy, or both, after recent cardiac catheterization or percutaneous transluminal coronary angioplasty. BACKGROUND: Femoral artery pseudoaneurysm formation after an interventional procedure is becoming more common as larger caliber catheters and prolonged anticoagulant and antiplatelet therapy are being used. Traditional treatment of this complication has been surgical repair. This study describes a new method of closing femoral pseudoaneurysms by using external compression guided by Doppler color flow imaging. METHODS: Fifteen patients, 3 undergoing cardiac catheterization and 12 undergoing coronary angioplasty, developed an expansile groin mass at the vascular access site diagnosed as a femoral artery pseudoaneurysm by Doppler ultrasound. Seven of the patients had undergone coronary stenting and were receiving postprocedural anticoagulant therapy. These patients underwent progressive graded mechanical (C-clamp) external compression guided by ultrasound. The mechanical compression was titrated to obliterate the vascular tracts to these aneurysms and maintain adequate flow in the femoral artery. RESULTS: After an average compression time of 30 min (range 10 to 120), these tracts remained closed. Follow-up ultrasound examination at 24 h or later confirmed continued closure in all. CONCLUSIONS: This study suggests that nonsurgical closure of femoral pseudoaneurysms is feasible. This technique may be valuable in managing vascular access-related complications after diagnostic and interventional procedures, even in patients requiring prolonged anticoagulant therapy.

Adult↗

Identification of patients with ventricular tachycardia after myocardial infarction: signal-averaged electrocardiogram, Holter monitoring, and cardiac catheterization.

Electrocardiographic signal averaging techniques have demonstrated a low-amplitude late potential and a long filtered QRS complex in patients with ventricular tachycardia (VT) after myocardial infarction. Complex ventricular ectopy and left ventricular aneurysms have also been associated with VT. The purposes of this study were (1) to determine whether the findings from the signal-averaged electrocardiogram (ECG) were independent of those from Holter monitoring and cardiac catheterization and (2) to determine the combination of findings from the signal-averaged ECG, cardiac catheterization, and Holter monitoring that best characterize patients with VT after myocardial infarction. We studied 174 patients after myocardial infarction, 98 of whom had recurrent sustained VT. By multivariate logistic regression only three parameters were found to be independently significant, listed in order of power: positive signal-averaged ECG (presence of a late potential or a long filtered QRS duration), peak premature ventricular contraction greater than 100/hr, and presence of a left ventricular aneurysm (p less than .001). The signal-averaged ECG provides independent information in identifying patients with VT after myocardial infarction.

Adolescent↗

A 5-y follow-up of the radiation exposure to in-room personnel during cardiac catheterization.

This study documents the radiation doses received by all in-room personnel of three cardiac catheterization laboratories where more than 15,000 cardiac procedures have been performed over a 5-y period. It is shown that all in-room personnel was exposed to a body dose equivalent well below any regulatory limits. However, some workers may have exceeded the occupational 150 mSv y-1 recommended limit for the lens of the eye. The physicians-in-training and the staff physicians are the two groups more likely to reach this limit. It is also demonstrated that a low correlation exists between the annual number of procedures and the annual head dose equivalent of a physician, but more variation is likely to originate from his/her working attitude and techniques. The mean dose equivalent at the collar level of the physicians is estimated to be 0.04 +/- 0.02 mSv per procedure.

Cardiac Catheterization↗