Electrodermal response audiometry with mentally defective children.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Middle-component AERs (8-90 msec) to tone-pips from 10 normal-hearing adults were subjected to three objective methods of response identification. Threshold was then determined for each subject according to four different rules. The criterion score, which considers conjointly latency and amplitude values across the middle-component peaks, was developed as a single-value measure for response-identification and subsequent threshold-determination procedures. One of the response-identification methods was applied to 10 hearing-impaired subjects; the results of the threshold-determination procedures were encouraging. Further directions toward improving objective response analysis are discussed.
OBJECTIVE: To evaluate the treatment efficacy of an electromechanical middle ear amplifier implant (AI) in patients with chronic moderate-to-severe sensorineural hearing loss (SNHL). The AI is a piezoelectric system with a sound processor and a rechargeable battery within a hermetically sealed titanium canister. Its titanium-sealed microphone is placed in the bony region of the ear canal. The incus-coupled transducer (actuator), which is also inside a titanium casing, is fastened to the adjacent bone. MATERIAL AND METHODS: This was a phase III study comprising 20 intention-to-treat patients. Telemetrical adjustments followed electromechanical amplifier implantations. We used a word recognition test as our primary efficacy measure (Freiburg Speech Recognition Test: DIN 45621). Secondary efficacy measures were the sentence comprehension test (Goettinger Satztest, 1996) for auditory orientation within noisy and quiet environments and a psychosocial adjustment test (Gothenburg Profile Test, 1998). The 6-month follow-up comprised a complete medical examination. Nineteen patients completed the study (per-protocol patients; 100% reference). RESULTS: Seventeen patients (89%) demonstrated improved binaural recognition of phonetically balanced monosyllables. Fourteen postoperative patients (74%) attained a perfect score (100%) on this test, compared to only 3 preoperative patients (16%). Thirteen patients (68%) reached the sentence recognition threshold at a 2:1 dB signal-to-noise ratio during noisy trials. Correct identification of the noise source direction in the horizontal plane occurred in 89% of the trials. The Gothenburg Profile Test scores showed that the subjective evaluation of hearing, orientation, social behavior and self-confidence increased from 48% to 88%. Three patients did not benefit from the implant. CONCLUSION: Treatment of SNHL with a totally implantable hearing system can be an efficient method for those patients unable to wear hearing aids. However, in order to avoid implantation in non-responders, there is a need for more specific audiological indication criteria.
The objective of this study was to investigate the clinical application of the ASSR (GSI Audera). It was completed in two parts: Study 1. Correlation between the ASSR-based threshold estimations and the conventional pure-tone thresholds in adults; and Study 2. Correlation between the average of the 2-4 kHz ASSR-based threshold estimations and c-ABR thresholds in children. The ASSRs were recorded in awake adults and sleeping infants with a range of hearing loss at CFs of 0.5 to 4 kHz and MFs between 46 and 95 Hz. The results show that in hearing-impaired adults (thresholds > 40 dBHL) good correlations can be observed between the behavioural thresholds and the ASSR-based threshold estimations. For the normal- to near-normal-hearing adults, a significant correspondence exists between the ASSR-based threshold estimations and FPTA. In children, strong correlations were found between the c-ABR and the 2-4 kHz ASSR-based threshold estimation average. These studies illustrate that the GSI Audera ASSR can accurately predict the behavioural audiogram in hearing-impaired subjects. In subjects with normal hearing the individual ASSR-based threshold estimations scatter too much. Instead the average of the ASSR-based threshold estimations corresponds well with the FPTA.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The brainstem response to brief tones contains a large vertex-positive component. If high-pass filter settings above 20 Hz are used, particularly with high rolloff slopes, the morphology of the response changes so that a vertex-negative wave becomes the most prominent component of the response. The amplitude of the response is unaffected by stimulus presentation rates of up to 35/sec. Tones with longer rise times have greater frequency specificity, but at rise times of greater than 5 msec, the brainstem response becomes very small. At high intensities, regardless of the rise time, the response to tones is not completely frequency specific, and notched noise masking should be used to obtain frequency-specific responses.
Explore the source record for details and available documents.
This study compared the reliability of a recently developed high-frequency audiometer (HFA) [Stevens et al., J. Acoust. Soc. Am. 81, 470-484 (1987)] with a less complicated system that uses supraaural earphones (Koss system). The new approach permits calibration on an individual basis, making it possible to express thresholds at high frequencies in dB SPL. Data obtained from 50 normal-hearing subjects, ranging in age from 10-60 years, were used to evaluate the effects on reliability of threshold variance, earpiece/earphone fitting variance, and the variance associated with the HFA calibration process. Without earpiece/earphone replacement, the reliability of thresholds for the two systems is similar. With replacement, the HFA showed poorer reliability than the Koss system above 11 kHz, largely due to errors in estimating the calibration function. HFA reliability is greater for subjects with valid calibration functions over the entire frequency range. When average correction factors are applied to the Koss data in an effort to convert threshold estimates to dB SPL, individual transfer functions are not represented accurately. Thus the benefit of being able to express thresholds at high frequencies in dB SPL must be weighed against the additional source of variability introduced by the HFA calibration process.
Auditory brain-stem responses (ABR) examination with simultaneous lobe-vertex (L-V) and membrane-vertex cm-v) recording was performed in 34 ears with cerebellopontine angle tumors. The detectability of wave I was better in M-V recording than in L-V recording, whereas L-V recording exhibited better detectability of wave V. ABR waveforms were classified into three groups, and the relations between the waveforms and the size of tumor or the degree of hearing loss were analyzed. Positive finding in ABR were obtained in 25 out of 34 ears in the present study. It was stressed that this dual recording in ABR was extremely useful in the diagnosis of cerebellopontine angle tumors.
The nature of the auditory brainstem potentials is studied, referring to the theory of the on-effect. The following stimuli are used: a click, a tone-burst of 3 kHz with a rise-decay time of 2 ms and a plateau of 1 ms, and finally different initial parts of the former tone-burst (the first 8, 4, 2, 1 cycles). Together with the electrical waveforms, the acoustic forms of the stimuli are described and the frequency spectra are measured. The auditory brainstem potential appears to be a pure onset response with a very short integration time. Only the initial part of the tone-burst (mainly the first oscillation) is responsible for eliciting the response. The consequences for the audiometric use of short tonal stimuli are discussed. Measurements of intensities or frequency spectra, technically or subjectively, of the whole tone-bursts are inappropriate, because the intensity and frequency content of the effective stimulus must be considered. The real frequency specificity then becomes much poorer and differs little from the click stimulation.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.