Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AIR CONDITIONING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31Linked to original sources

Measurement of tracheobronchial dose from simultaneous exposure to environmental radon and thoron progeny.

According to the theory and idea of Hopke et al., a bronchial dosimeter consisting of multiple metal screens has been developed to measure the deposition fractions of radon and thoron progeny in the nasal (N) and tracheobronchial (T-B) regions of the human respiratory tract and to give the dose conversion factors in the T-B region in units of mGy WLM(-1) and mSv y(-1) per Bq m(-3). Different air treatments have been performed in a closed laboratory, which include the use of air conditioning and the application of positive and negative ions for the investigation of the change of the dose conversion factors. At the same time, the radon and thoron gas concentrations have also been measured in the laboratory by active sampling using newly designed activated charcoal canisters connected in series with the bronchial dosimeter for the calculation of the resulted annual effective dose under different air treatments. It is observed that the calculated dose conversion factors derived from the bronchial dosimeter have large discrepancies with those computed using existing lung models. It has also been found that the application of negative ions cannot reduce the annual effective dose in the T-B region; the application of positive ions can lead to a reduction, but not as much as the use of air conditioning. The mitigation of radon effects by air conditioning demonstrated using the bronchial dosimeter is more prominent than that shown by using lung models.

Air Pollutants, Radioactive↗

Use of an indoor air quality model (IAQM) to estimate indoor ozone levels.

Currently, outdoor ozone levels in many U.S. cities exceed the primary health-based national ambient air quality standard. While outdoor ozone levels are an important measure of the severity of those exceedances, people typically spend more than 80 percent of their time indoors, where ozone levels are lower. Indoor ozone levels range from 10 to 80 percent of outdoor levels, with many people receiving a substantial portion of their ozone exposure while indoors. This paper uses an indoor air quality model (IAQM) to estimate indoor ozone levels by microenvironment type (home, office, and vehicle) and configuration (windows open, windows closed, older construction, weatherized, and air conditioned). The formulation of IAQM is discussed, along with specification of model parameters for ozone. The multicompartment version of IAQM is described, with a single-compartment version used for the analyses. IAQM-calculated ozone indoor-outdoor ratios compare well with research-reported values. Results indicate that ozone peak-concentration indoor-outdoor ratios range as follows: home--0.65 (windows open), 0.36 (air conditioned), 0.23 (typical construction, windows closed), and 0.05 (energy-efficient construction, windows closed); office--0.82 (heating, ventilation and air conditioning systems supplying 100 percent outdoor air), 0.60 (typical HVAC), and 0.32 (energy-efficient HVAC); and vehicle--0.41 (85 mph), 0.33 (55 mph), and 0.21 (10 mph). Analysis results are presented to characterize IAQM's sensitivity to assumed model parameters.

Air Pollutants↗

The impact of global warming on health and mortality.

Initial concern about the possible effects of global warming on infections has declined with the realization that the spread of tropical diseases is likely to be limited and controllable. However, the direct effects of heat already cause substantial numbers of deaths among vulnerable people in the summer. Action to prevent these deaths from rising is the most obvious medical challenge presented by a global rise in temperature. Strategies to prevent such deaths are in place to some extent, and they differ between the United States and Europe. Air conditioning has reduced them in the United States, and older technologies such as fans, shade, and buildings designed to keep cool on hot days have generally done so in Europe. Since the energy requirements of air conditioning accelerate global warming, a combination of the older methods, backed up by use of air conditioning when necessary, can provide the ideal solution. Despite the availability of these technologies, occasional record high temperatures still cause sharp rises in heat-related deaths as the climate warms. The most important single piece of advice at the time a heat wave strikes is that people having dangerous heat stress need immediate cooling, eg, by a cool bath. Such action at home can be more effective than transporting the patient to hospital. Meanwhile, it must not be forgotten that cold weather in winter causes-many more deaths than heat in summer, even in most subtropical regions, and measures to control cold-related deaths need to continue.

Aged↗

The Stafford outbreak of Legionnaires' disease.

A large outbreak of Legionnaires' disease was associated with Stafford District General Hospital. A total of 68 confirmed cases was treated in hospital and 22 of these patients died. A further 35 patients, 14 of whom were treated at home, were suspected cases of Legionnaires' disease. All these patients had visited the hospital during April 1985. Epidemiological investigations demonstrated that there had been a high risk of acquiring the disease in the out patient department (OPD), but no risk in other parts of the hospital. The epidemic strain of Legionella pneumophila, serogroup 1, subgroup Pontiac 1a was isolated from the cooling water system of one of the air conditioning plants. This plant served several departments of the hospital including the OPD. The water in the cooling tower and a chiller unit which cooled the air entering the OPD were contaminated with legionellae. Bacteriological and engineering investigations showed how the chiller unit could have been contaminated and how an aerosol containing legionellae could have been generated in the U-trap below the chiller unit. These results, together with the epidemiological evidence, suggest that the chiller unit was most likely to have been the major source of the outbreak. Nearly one third of hospital staff had legionella antibodies. These staff were likely to have worked in areas of the hospital ventilated by the contaminated air conditioning plant, but not necessarily the OPD. There was evidence that a small proportion of these staff had a mild legionellosis and that these 'influenza-like' illnesses had been spread over a 5-month period. A possible explanation of this finding is that small amounts of aerosol from cooling tower sources could have entered the air-intake and been distributed throughout the areas of the hospital served by this ventilation system. Legionellae, subsequently found to be of the epidemic strain, had been found in the cooling tower pond in November 1984 and thus it is possible that staff were exposed to low doses of contaminated aerosol over several months. Control measures are described, but it was later apparent that the outbreak had ended before these interventions were introduced. The investigations revealed faults in the design of the ventilation system.

Adult↗

Humid air increases airway resistance in asthmatic subjects.

Eight persons with asthma were exposed to seven air conditions varying in temperature (37 degrees C to 49 degrees C [98.6 degrees F to 120.2 degrees F]) and water content (44 mg H2O per liter to 79 mg H2Oper liter) . Normocapnic hyperventilation for three minutes at 40% maximal voluntary ventilation was carried out for each condition. A constant-volume body plethysmograph measured the functional residual capacity and specific airway conductance (SGaw), followed by two forced expiratory manuevers. Measurements were taken before and 1, 5, 10, and 20 minutes after each challenge. Air conditions with 100% relative humidity caused a fall in the SGaw that was maximal in 1 minute. Air conditions at 100% relative humidity caused a greater fall in both the forced expiratory volume in 1 second (FEV1) (P<.05) and the SGaw (P<.005) than did conditions of the same temperature but less water content. At 44 degrees C and 100% relative humidity, the mean percent change in FEV1 and SGaw was -2% and -40%, respectively, at 1 minute after challenge. Of the conditions examined, the optimal temperature was 44 degrees C, and we speculate that the optimal water content is less than 44 mg H2O per liter. Inhaled water concentrations exceeding 44 mg H2O per liter should probably not be used in patients with asthma.

Adult↗

Laryngeal mucosa elasticity and viscosity in high and low relative air humidity.

In earlier work we showed that low relative humidity (RH) of inhaled air causes acoustic voice parameters such as jitter and shimmer to deteriorate. Other authors have shown negative effects on vocal efficiency. To explain these changes in the mechanical properties of the vocal folds, the effects of changes in RH of the air passing over microdissected mucosa of sheep larynges were studied. The dissected surface of the tissue specimen just touched Ringer solution and air of varying RH was blown over the specimen. The mucosa specimen was subjected to sinusoidal oscillations of length (strain) and the resulting force (stress) was measured. The gain and phase angle between the imposed strain and resulting stress were measured, and elasticity and viscosity were calculated. Two different air conditions were tested: air with high RH (100%) vs air with low RH (0%). Viscosity and stiffness increased significantly in both ambient conditions (P < 0.01). Dry dehydrating air resulted in a stiffer and more viscous cover than humid air (P < 0.001). These changes in mechanical characteristics may contribute to the effects on voice parameters described in earlier work.

Animals↗

Computerized infrared thermographic imaging and pulpal blood flow: Part 1. A protocol for thermal imaging of human teeth.

AIM: To observe the thermographic appearance of teeth and to develop a suitable protocol for imaging teeth in human subjects using modern thermographic imaging (TI) equipment in a thermologically controlled environment. METHODOLOGY: The emissivity of enamel was investigated using an extracted incisor tooth. A total of 12 unrestored maxillary lateral incisors in six healthy patients were then imaged under rubber dam after a 20-min equilibration period and the thermographic data analysed using a dedicated software package. Recordings were made from standardized gingival and incisal sites on each tooth and the temperature gradient established for each tooth. Subsequently, a sequence of images of both maxillary central incisors in one patient was stored every 30 s during a 20-min equilibration period with and without an air-conditioning unit in operation. RESULTS: For the lateral incisors there was a consistent temperature gradient (mean 1.28 degrees C) from gingival area to incisal area and there were no statistically significant differences between right and left sides for the gingival site (t = 0.34, NS) or the incisal site (t = 0.62, NS). The air-conditioning unit had a rapid and profound cooling effect. With the air-conditioning disabled there was a mean tooth surface temperature increase of 1.1 degrees C from 0 to 5 min of the equilibration period and 0.3 degree C from 15 to 20 min. CONCLUSIONS: There was no significant difference in gingival or incisal temperatures between pairs of contralateral maxillary lateral incisors and a consistent temperature gradient existed from gingival to incisal areas of healthy maxillary lateral incisor teeth. The protocol described is suitable for TI of vital teeth. However, TI measured tooth surface temperature only which was extremely sensitive to air currents. A 15-min acclimatization period under rubber dam was adequate to allow stable tooth surface temperature measurement.

Adolescent↗

Microvascular anatomy of the nose.

The microvasculature of the nose consists of: 1) A dense subepithelial network of capillaries, with fenestrations between the endothelial cells. This network provides nutrients to the epithelium and glands, and allows passage of water into the lumen for evaporation and air-conditioning. 2) A system of capacitance vessels or sinuses, which when they distend, block the nasal lumen, and when they empty, open the nasal passages. Changes in their volume will affect the filtering and air-conditioning functions of the nose. 3) Arteriovenous anastomoses which allow rapid passage of blood through the mucosa. They are probably important in air-conditioning, and in the countercurrent mechanisms that tend to keep the brain cool in a hot dry climate. The anatomical interrelationships between these different systems is not well understood, nor is their differential control in terms of actions of mediators and nerves. In neurogenic inflammation sensory nerves are excited and release local mediators such as substance P via axon reflexes. These sensory neuropeptides will cause vasodilatation, vascular congestion and extravasation of liquid from the postcapillary venules, with resultant oedema and exudate. They may also cause secretion from the submucosal glands.

Arteriovenous Anastomosis↗

Effect of NAPL entrapment conditions on air sparging remediation efficiency.

The effect of soil heterogeneity and the entrapment condition of NAPL source on the mass removal efficiency of air sparging coupled with soil vapour extraction (AS/SVE) was investigated using an intermediate scale two-dimensional laboratory soil tank. Four different NAPL entrapments were created by varying the height of the water table in heterogeneous soil models. Different mass removal efficiencies were achieved for different NAPL entrapment conditions, which were governed by soil heterogeneity and water table height before and during AS/SVE operation. Remobilization and redistribution of toluene and water improved the mass removal. Overall results suggested that it was difficult to achieve the complete remediation of NAPL source due to complex entrapment in heterogeneous soil system. In order to assess the potential contamination in the post-remediation stage, gas and dissolved concentrations of toluene were measured after the AS/SVE operation. The results showed that gas concentration close to remaining NAPL source zone increased rapidly and reached to steady state values, which were much smaller than the vapour pressure, whereas the aqueous phase concentrations increased continuously toward the solubility limit.

Air↗

[Sick building syndrome: three case reports].

SBS--sick building syndrome--is a set multi-organ symptoms related to long-term staying in "sick buildings". These are modern, energy saving, air tight buildings with reduced ventilation. As a result of such construction, harmful, air-borne substances issued by interior decoration materials, air-conditioning systems and working people are cumulated. The study presents three cases of allergic patients whose original allergic illnesses got aggravated as an effect of: 1) staying in a freshly redecorated room, 2) staying in a fully air-conditioned room, 3) long-term exposition to bacteria and fungi allergens developing in old, used up filters of a car air-condition system.

Adult↗

Measurements of carbonyls in a 13-story building.

BACKGROUND, AIM AND SCOPE: Formaldehyde and acetaldehyde are emitted by many mobile and stationary sources and secondary aldehydes are intermediates in the photo-oxidation of organic compounds in the atmosphere. These aldehydes are emitted indoors by many materials such as furniture, carpets, heating and cooling systems, an by smoking. Carbonyls, mainly formaldehyde and acetaldehyde, have been studied because of their adverse health effects. In addition, formaldehyde is a suspected carcinogen. Therefore, the concentrations of formaldehyde and acetaldehyde were determined to assess the inhalation exposure doses to carbonyls for people who work in a 13-story building and in order to evaluate the cancer hazard. METHODS: Carbonyl compounds in indoor and outdoor air were measured at a 13-story building located in Mexico City. The mezzanine, fifth and tenth floors, and the third level-parking garage were selected for sampling. Samples were collected in two sampling periods, the first from April 20 to 29, 1998 and the second from December 1 to 20, 1998. Carbonyls were sampled by means of DNHP-coated cartridges at a flow rate of 1 l min(-1) from 9:00 to 19:00 hours, during 2-hour time intervals and analyzed by HPLC with hours, during 2-hour time intervals and analyzed by HPLC with UV/VIS detection. RESULTS: Mean carbonyl concentrations were highest in the 3rd level-parking garage, with the formaldehyde concentration being the highest ranging from 108 to 418 microg m(-3). In working areas, the highest carbonyl arithmetic mean concentrations (AM) were observed on the 5th floor. Acetone and formaldehyde concentrations were highest in April ranging from 161 to 348 microg m(-3) (AM = 226) and from 157 to 270 microg m(-3) (AM = 221), respectively. Propionaldehyde and butyraldehyde were present in smaller concentrations ranging from 2 to 25 and 1 to 28 microg m(-3), respectively, considering all the samples. Mean indoor/outdoor ratios of carbonyls ranged from 1.8 to 9.6. A reduction of inhalation exposure doses of 41% and 45% was observed in the fifth floor air after the air conditioning systems had been repaired. Formaldehyde and acetaldehyde concentrations were higher in smoking environments. CONCLUSION: Indoor carbonyl concentrations were significantly greater than outdoor concentrations. Tobacco smoke seems to be the main indoor source of formaldehyde. After the air conditioning system was maintained and repaired (as was recommended), an important reduction in the emission of formaldehyde and acetaldehyde was achieved on all floors, except for the 3rd level parking garage, thereby reducing the inhalation exposure doses. RECOMMENDATION: The results obtained in this research demonstrated that maintenance of air conditioning systems must be carried out regularly in order to avoid possible adverse effects on health. Additionally, it is mandatory that isolated smoking areas, with air extraction systems, be installed in every public building.

Acetaldehyde↗

Measurement of volatile organic compounds inside automobiles.

The objective of the current study was to evaluate the types and concentrations of volatile organic compounds (VOCs) in the passenger cabin of selected sedan automobiles under static (parked, unventilated) and specified conditions of operation (i.e., driving the vehicle using air conditioning alone, vent mode alone, or driver's window half open). Data were collected on five different passenger sedan vehicles from three major automobile manufacturers. Airborne concentrations were assessed using 90-min time-weighted average (TWA) samples under U.S. Environmental Protection Agency (USEPA) Method IP-1B to assess individual VOC compounds and total VOCs (TVOCs) calibrated to toluene. Static vehicle testing demonstrated TVOC levels of approximately 400-800 microg/m(3) at warm interior vehicle temperatures (approximately 80 degrees F), whereas TVOCs at least fivefold higher were observed under extreme heat conditions (e.g., up to 145 degrees F). The profile of most prevalent individual VOC compounds varied considerably according to vehicle brand, age, and interior temperature tested, with predominant compounds including styrene, toluene, and 8- to 12-carbon VOCs. TVOC levels under varied operating conditions (and ventilation) were generally four- to eightfold lower (at approximately 50-160 microg/m(3)) than the static vehicle measurements under warm conditions, with the lowest measured levels generally observed in the trials with the driver's window half open. These data indicate that while relatively high concentrations of certain VOCs can be measured inside static vehicles under extreme heat conditions, normal modes of operation rapidly reduce the inside-vehicle VOC concentrations even when the air conditioning is set on recirculation mode.

Air Pollution, Indoor↗

Heat-related illness and death, Wisconsin, 1995.

This article examines heat-related illnesses and deaths that occurred in Wisconsin during the summer of 1995, which was among the warmest seasons on record. Death certificates that listed heat exposure as a contributing or underlying cause of 154 deaths and ambulance run reports for 454 heat-related emergency calls were analyzed. The time and place of these events and patient information were used to evaluate risk factors such as age, medical condition, physical activity, and environmental temperature. Three-fourths of the deaths and nearly half of the heat-related illnesses occurred during or shortly after two days of intense heat. Major risk factors for these heat-related illnesses and deaths included age, underlying chronic illness, physical exertion, and lack of air-conditioning. To reduce the number of illnesses and deaths that occur during future heat waves, all residents should be advised to install air-conditioning systems in their homes or apartments and encouraged to use them when indoor temperatures are uncomfortably warm. Summer weather forecasts should include heat index information. During periods of extreme heat, public health advisories should be issued encouraging residents to seek shelter in air-conditioned areas and to avoid strenuous outdoor activities and prolonged sun exposure. Region-specific criteria and procedures for issuing public health advisories should be developed jointly by the National Weather Service and the US Centers for Disease Control and Prevention.

Adolescent↗

Dynamic evaluation of airflow rates for a variable air volume system serving an open-plan office.

In a typical air-conditioned office, the thermal comfort and indoor air quality are sustained by delivering the amount of supply air with the correct proportion of outdoor air to the breathing zone. However, in a real office, it is not easy to measure these airflow rates supplied to space, especially when the space is served by a variable air volume (VAV) system. The most accurate method depends on what is being measured, the details of the building and types of ventilation system. The constant concentration tracer gas method as a means to determine ventilation system performance, however, this method becomes more complicated when the air, including the tracer gas is allowed to recirculate. An accurate measurement requires significant resource support in terms of instrumentation set up and also professional interpretation. This method deters regular monitoring of the performance of an airside systems by building managers, and hence the indoor environmental quality, in terms of thermal comfort and indoor air quality, may never be satisfactory. This paper proposes a space zone model for the calculation of all the airflow parameters based on tracer gas measurements, including flow rates of outdoor air, VAV supply, return space, return and exfiltration. Sulphur hexafluoride (SF6) and carbon dioxide (CO2) are used as tracer gases. After using both SF6 and CO2, the corresponding results provide a reference to justify the acceptability of using CO2 as the tracer gas. The validity of using CO2 has the significance that metabolic carbon dioxide can be used as a means to evaluate real time airflow rates. This approach provides a practical protocol for building managers to evaluate the performance of airside systems.

Air Conditioning↗

The effect of domestic factors on respiratory symptoms and FEV1.

This study was conducted to determine whether indoor air pollution factors affected respiratory function and symptoms in 1357 non-smoking Caucasian children. Interviews were conducted to determine: exposure to pets and to gases, vapours and dusts from hobbies; the use of gas stoves; fireplaces, air conditioners and humidifiers; type of heating systems; and the number of residents, and the number of smokers in the home. The forced expiratory volume in one second (FEV1) was obtained from maximum expiratory flow volume curves, and symptoms from the application of a standardized questionnaire. Indoor pets and the use of fireplaces and humidifiers had no consistent relationships with FEV1 when considered individually or in combination with the other factors. Hobbies, the use of gas stoves, the absence of air conditioning, the use of hot water heating, crowded homes, and the presence of smokers in the home all had negative relationships with FEV1. The largest effect on lung function was observed in children from homes with hot water heating systems, whereas the smallest effect was observed in children with smokers in the home. Children who lived in homes with hot water heating systems with no air conditioning had mean FEV1 of up to 0.4 litres lower than did their counterparts who lived in homes with forced air heating and air conditioning. Pets, heating systems, cooking fuel, crowding and passive smoking showed no consistent effects on the reporting of any of the symptoms. Girls who were exposed to the emissions from indoor hobbies reported more phlegm, wheeze and dyspnoea.

Adolescent↗

Analysis of atmospheric conditions during air pollution episodes in Ankara, Turkey.

This paper presents a detailed analysis of the meteorological conditions that are associated with strong air pollution episodes in Ankara, Turkey. Based on climatological and air quality data [SO2 and TSP (total suspended particulates)] obtained for the winter months during 1989-1994, the analysis showed that the presence of weak atmospheric pressure gradients and warm air advection were the most important factors leading to high SO2 and TSP concentrations. In addition, the onset of the high air pollution episodes was generally associated with a trend toward negative vorticity at the 850-hPa level.

Air Movements↗

Comparison of health problems related to work and environmental measurements in two office buildings with different ventilation systems.

A cross sectional survey investigating "building sickness" was carried out in two buildings with similar populations of office workers but differing ventilation systems, one being fully air conditioned with humidification and the other naturally ventilated. The prevalence of symptoms related to work was assessed by a questionnaire administered by a doctor. A stratified, randomly selected sample of workers was seen (84% response). Building sickness includes several distinct syndromes related to work, most of which were significantly more common in the air conditioned building than the naturally ventilated building--namely, rhinitis (28% v 5%), nasal blockage and dry throat (35% v 9%), lethargy (36% v 13%), and headache (31% v 15%). The prevalence of work related asthma and humidifier fever was low and did not differ significantly between the two buildings. An environmental assessment of the offices was performed to attempt to identify possible factors responsible for the differences in the prevalence of disease. Globe temperature, dry bulb temperature, relative humidity, moisture content, air velocity, positive and negative ions, and carbon monoxide, ozone, and formaldehyde concentrations were all measured. None of these factors differed between the buildings, suggesting that building sickness is caused by other factors.

Air Conditioning↗

R-134a emissions from vehicles.

We report the first study of R-134a (also known as HFC-134a and CF3CFH2) refrigerant leakage from air conditioning (AC) systems of modern vehicles. Twenty-eight light duty vehicles from five manufacturers (Ford, Toyota, Daimler Chrysler, General Motors, and Honda) were tested according to the USEPA (Federal) extended diurnal test procedure using the Sealed Housing for Evaporative Determination (SHED) apparatus. All tests were conducted using stationary vehicles with the motor and air conditioning system turned off. R-134a was measured using gas chromatography (GC) with a flame ionization detector (FID). All vehicles exhibited measurable R-134a leakage over the 2-day diurnal test. Leak rates of R-134a ranged from 0.01 to 0.36 g/day with an average of 0.07+/-0.07 g/day. When combined with leakage associated with vehicle operation, servicing, and disposal we estimate that the lifetime average R-134a emission rate from an AC equipped vehicle is 0.41+/-0.27 g/day (the majority of emissions are associated with vehicle servicing and disposal). Assuming that the average vehicle travels 10 000 miles per year we estimate that the global warming impact of R-134a leakage from an AC equipped vehicle is approximately 4-5% of that of the CO2 emitted by the vehicle. The results are discussed with respect to the contribution of vehicle emissions to global climate change.

Aerosol Propellants↗