Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “data independence acquisition”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

Accuracy of quantitative MR vessel wall imaging applying a semi-automated gradient detection algorithm--a validation study.

UNLABELLED: Magnetic resonance imaging (MRI) is uniquely suited to study the pathophysiology of arteriosclerosis. So far, magnetic resonance (MR) measurements of vessel dimensions have mainly been done by manual tracing of vessel wall contours. However, such data postprocessing is very time-consuming and has limited accuracy due to difficulties in precise tracing of the thin vessel wall. PURPOSE: To assess the accuracy and reproducibility of quantitative vascular MR imaging applying a data analysis method based on (1) vessel wall unwrapping, followed by (2) a gradient detection algorithm for MR data postprocessing. Vascular MR imaging studies were done both in vessel phantoms and in healthy volunteers (n=29) on a clinical 1.5 T MR scanner. A dark blood double-inversion turbo spin echo sequence with fat suppression was applied, with proton-density-weighted and breath-hold acquisition for aortic imaging and T2-weighted acquisition for carotid imaging. Intraobserver and interobserver variability were systematically evaluated by two independent observers. A repeat study within 10 days of the first MRI was performed in 10 of these subjects for assessment of interstudy reproducibility. RESULTS: The semiautomated edge detection software revealed a clear view of the inner and outer vessel wall boundaries both in the phantoms and in the volunteers studied. There was close agreement between MR-derived measurements and phantom dimensions (mean difference of 1.1+/-16.9 mm2, 8.0+/-19.9 mm2, 9.0+/-12.1 mm2 for vessel wall cross-sectional area, inner vessel area, and total vessel area, respectively). Quantification of vessel dimensions was feasible in all 29 healthy volunteers studied. Semiautomated quantification of cross-sectional vessel wall area (mean+/-SD, 253.6+/-208.4 mm2) revealed close correlation for repeated measurements by one or two observers (r=0.99 each). Both intraobserver and interobserver variability of vessel wall area MR measurements were low (mean difference 7.5+/-16.7 mm2 and 14.4+/-24.6 mm2 , respectively). In the repeat study of 10 volunteers, MRI with semiautomated postprocessing quantitation revealed a high correlation and agreement of vessel dimensions between the two scans (r=0.994, mean difference 2.6+/-25.1 mm2). CONCLUSION: Semiautomated analysis methods can provide approaches that benefit from the human understanding of the image and the computer's ability to measure precisely and rapidly. Thus, by combining the latest MRI methods and semiautomated image analysis methods, we are now able to reproducibly determine the geometric parameters of blood vessels.

Adult↗

Passage of classical swine fever virus in cultured swine kidney cells selects virus variants that bind to heparan sulfate due to a single amino acid change in envelope protein E(rns).

Infection of cells with Classical swine fever virus (CSFV) is mediated by the interaction of envelope glycoprotein E(rns) and E2 with the cell surface. In this report we studied the role of the cell surface glycoaminoglycans (GAGs), chondroitin sulfates A, B, and C (CS-A, -B, and -C), and heparan sulfate (HS) in the initial binding of CSFV strain Brescia to cells. Removal of HS from the surface of swine kidney cells (SK6) by heparinase I treatment almost completely abolished infection of these cells with virus that was extensively passaged in swine kidney cells before it was cloned (clone C1.1.1). Infection with C1.1.1 was inhibited completely by heparin (a GAG chemically related to HS but sulfated to a higher extent) and by dextran sulfate (an artificial highly sulfated polysaccharide), whereas HS and CS-A, -B, and -C were unable to inhibit infection. Bound C1.1.1 virus particles were released from the cell surface by treatment with heparin. Furthermore, C1.1.1 virus particles and CSFV E(rns) purified from insect cells bound to immobilized heparin, whereas purified CSFV E2 did not. These results indicate that initial binding of this virus clone is accomplished by the interaction of E(rns) with cell surface HS. In contrast, infection of SK6 cells with virus clones isolated from the blood of an infected pig and minimally passaged in SK6 cells was not affected by heparinase I treatment of cells and the addition of heparin to the medium. However, after one additional round of amplification in SK6 cells, infection with these virus clones was affected by heparinase I treatment and heparin. Sequence analysis of the E(rns) genes of these virus clones before and after amplification in SK6 cells showed that passage in SK6 cells resulted in a change of an Ser residue to an Arg residue in the C terminus of E(rns) (amino acid 476 in the polyprotein of CSFV). Replacement of the E(rns) gene of an infectious DNA copy of C1.1.1 with the E(rns) genes of these virus variants proved that acquisition of this Arg was sufficient to alter an HS-independent virus to a virus that uses HS as an E(rns) receptor.

Amino Acid Sequence↗

Water-vapor detection using asynchronous THz sampling.

The use of a fiber-coupled terahertz (THz) transmitter/receiver pair for spectroscopic detection of water vapor is investigated. Transmission signals of an alumina cylinder demonstrate that the measurement approach can be applied in a windowless ceramic combustor. First, a conventional commercial transmitter/receiver pair is used to make measurements for frequencies to 1.25 THz. Water-vapor absorption is clearly evident within the alumina transparency window and is readily modeled using existing databases. A variety of data-acquisition schemes is possible using THz instrumentation. To assess signal-collection techniques, a prototype THz transmitter/receiver pair is then used with the asynchronous optical-sampling (ASOPS) technique to obtain asynchronous THz-sampling signals to 1 THz without the need for an optomechanical delay line. Two mode-locked Ti:sapphire lasers operating at slightly different repetition rates are used for pumping the transmitter and receiver independently to permit a complete time-domain THz signal to be recorded. The resulting repetitive phase walkout is demonstrated by collecting power spectra of room air that exhibit water-vapor absorption.

Absorption↗

Metabolites of 5-fluorouracil in plasma and urine, as monitored by 19F nuclear magnetic resonance spectroscopy, for patients receiving chemotherapy with or without methotrexate pretreatment.

19F NMR spectroscopy at 470 MHz (11.7 Tesla) has been used to directly measure the levels of 5-fluorouracil (FU) and its fluorine-containing catabolites in plasma and urine of colon cancer patients after i.v. infusion (10 min) of 60-230 mumol (8-30 mg) FU/kg, either with or without pretreatment with methotrexate (5.1-12.5 mg/kg). With a 1.5-ml sample the minimum metabolite concentration that can be quantified is approximately 15 +/- 5 microM within 30 min and 3 +/- 1 microM within 12 h of data acquisition. The first and second catabolites of FU, dihydrofluorouracil and alpha-fluoro-beta-ureidopropanoic acid, exhibit steady-state behavior with dose-dependent plasma concentrations of 5-40 microM for approximately 10-90 min after infusion (12 patients, 16 treatments). The final catabolite alpha-fluoro-beta-alanine (FBAL) was detected in plasma after 5-15 min, and the rate at which its concentration increased was independent of FU dose, while the maximum concentration reached at about the time FU disappeared (FU less than 5 microM in 1-2 h) was dose-dependent. The area under the time curve for FU in plasma increased more than linearly with dose. Several patients showed elevated levels of free fluoride anion (F-) in plasma (63 samples: median, 5 microM; maximum, 33 microM). In urine all of the above catabolites and F- could be observed. In samples with pH greater than or equal to 7.3 (methotrexate patients, due to bicarbonate infusion) N-carboxy-FBAL was also found in significant amounts. Urinary excretion of FU and catabolites amounted to 2.6-30% of the dose within 2 h (14 patients, 18 treatments) and 60-66% within 24 h (three patients). The ratio FU/creatinine in 2-h urine increased more than linearly with FU dose. Urinary fluoride concentration reached a maximum during the first day after FU infusion and returned to normal background levels after 2-3 days (four patients). The pattern of FU catabolites observed in plasma or urine did not differ significantly between responders and nonresponders to therapy or between patients with FU monotherapy and patients with methotrexate pretreatment. Cytotoxic FU anabolites, i.e., nucleotides, were not detected in plasma or urine (i.e., are less than 3 microM). Their detection in tumor tissue will be required for an assessment of individual responsiveness to FU. Possible toxic metabolic products derivable from FBAL, e.g., 2-fluoroacetate or 2-fluorocitrate, were not detected (i.e., are less than 3 microM) in plasma or urine.(ABSTRACT TRUNCATED AT 400 WORDS)

Aged↗

Memory deficits subsequent to chronic consumption of alcohol in mice: an analysis based on spontaneous alternation behavior.

Male mice of the BALB/c strain were given a solution of 15% ethanol as their only source of fluid for periods varying from 5 weeks to 8 months. For behavioral testing, they were compared with control groups which had received either an isocaloric solution of sucrose or tap water. Memory was tested by using spontaneous alternation behavior in a T maze. Each test consisted of two forced trials (acquisition) followed by a free trial (test) given at different acquisition--test intervals (from 30 s to 24 h). Results from two independent experiments showed that after 25 weeks of ethanol administration there was an accelerated rate of decay of spontaneous alternation as a function of the acquisition--test interval. Such a phenomenon persisted after ethanol was omitted from the diet. A third experiment showed that when tested on two successive sessions separated by a 5 h interval, experimental subjects exhibited a decreased ability to perform normally on the second test. Our data are interpreted as showing that long-term ethanol administration results in accelerated forgetting and increased vulnerability to proactive interference and, as such, they are compared to the memory dysfunctions observed in amnesic patients.

Alcohol Drinking↗

A rate-controlled indentor for in vivo analysis of residual limb tissues.

A tissue tester was designed to enable rate-controlled indentation of the bulk soft tissues of lower extremity residual limbs. The tissue tester employs a digital linear actuator that implements rate-controlled indentation, and a load cell that measures the reaction force resulting from tissue indentation. Viscoelastic phenomena such as preconditioning, hysteresis and force relaxation can be assessed, and the effect of varying indentation rates on soft tissue stiffness can be investigated. The device accommodates indentor excursions up to 30 mm, indentation at rates of 0 to 10 mm/s, reaction forces up to 44 N, and multiple loading/unloading cycles. The tissue tester is controlled via a notebook personal computer with a PCMCIA data acquisition card. The tissue testing trials are automated and the entire test system is portable and amenable for use in a clinical or research environment. System output consists of force-displacement curves from cyclic loading, and force-time curves following ramped-step indentation. The mean indentor positioning error was 0.071 (+/-0.75)% of the desired displacement. This error varied as a function of indentation and was approximately independent of the indentation rate. Indentation rates were accurate to within 0.94(+/-0.68)% of the desired value and also varied with indentation. Indentation of a viscoelastic foam yielded force-displacement curves that were consistent with that obtained from an Instron universal testing machine.

Amputation Stumps↗

Replication, integration, and packaging of plasmid DNA following cotransfection with baculovirus viral DNA.

Infection-dependent replication assays have been used to identify numerous putative origins of baculovirus replication. However, plasmid DNA, when cotransfected into insect cells with Autographa californica multinucleocapsid nucleopolyhedrovirus (AcMNPV) DNA, replicates independently of any viral sequence in cis (11). Cotransfection of transfer plasmids and baculovirus DNA is a common procedure used in generating recombinant viruses and in measuring the level of gene expression in transient-expression assays. We have examined the fate of a series of vector plasmids in cotransfection experiments. The data reveal that these plasmids replicate following cotransfection and the replication of plasmid DNA is not due to acquisition of viral putative origin sequences. The conformation of plasmid DNA replicating in the cotransfected cells was analyzed and found to exist as high-molecular-weight concatemers. Ten to 25% of the replicated plasmid DNA was integrated into multiple locations on the viral genome and was present in progeny virions following serial passage. Sequence analysis of plasmid-viral DNA junction sites revealed no homologous or conserved sequences in the proximity of the integration sites, suggesting that nonhomologous recombination was involved during the integration process. These data suggest that while a rolling-circle mechanism could be used for baculovirus DNA replication, recombination may also be involved in this process. Plasmid integration may generate large deletions of the viral genome, suggesting that the process of DNA replication in baculovirus may be prone to generation of defective genomes.

Animals↗

The bias flow nitrogen washout technique for measuring the functional residual capacity in infants. ERS/ATS Task Force on Standards for Infant Respiratory Function Testing.

The functional residual capacity (FRC) is the most commonly measured static lung volume in infants. It is important for interpreting volume-dependent pulmonary mechanics, e.g. airway resistance, and defining normal lung growth. The bias flow nitrogen washout technique is widely used for measuring FRC because the dead space and circuit resistance are low, making it suitable for small or sick infants. Moreover, data acquisition and calculation are easily programmed for a personal computer. The aim of this paper is to provide recommendations pertaining to equipment requirements, study procedures and reporting of data for functional residual capacity measurements. While measuring the functional residual capacity is regarded as physiologically and clinically important, the accuracy of the measurement is undoubtedly equally important. Hence, the paper also emphasizes factors influencing the accuracy of functional residual capacity measurements independent of equipment requirements. These recommendations represent the "State of the Art" in 2000.

Clinical Protocols↗

Right-left asymmetries in the whisking behavior of rats anticipate head movements.

Rats use rhythmic movements of their vibrissae (whiskers) to tactually explore their environment. This "whisking" behavior has generally been reported to be strictly synchronous and symmetric about the snout, and it is thought to be controlled by a brainstem central pattern generator. Because the vibrissae can move independently of the head, however, maintaining a stable perception of the world would seem to require that rats adjust the bilateral symmetry of whisker movements in response to head movements. The present study used high-speed videography to reveal dramatic bilateral asymmetries and asynchronies in free-air whisking during head rotations. Kinematic analysis suggested that these asymmetric movements did not serve to maintain any fixed temporal relationship between right and left arrays, but rather to redirect the whiskers to a different region of space. More specifically, spatial asymmetry was found to be strongly correlated with rotational head velocity, ensuring a "look-ahead" distance of almost exactly one whisk. In contrast, bilateral asynchrony and velocity asymmetry were only weakly dependent on head velocity. Bilateral phase difference was found to be independent of the whisking frequency, suggesting the presence of two distinct left and right central pattern generators, connected as coupled oscillators. We suggest that the spatial asymmetries are analogous to the saccade that occurs during the initial portion of a combined head-eye gaze shift, and we begin to develop the rat vibrissal system as a new model for studying vestibular and proprioceptive contributions to the acquisition of sensory data.

Animals↗

MIMOSA: a functional model of the management of medical images.

The concept of picture archiving and communication system (PACS) appeared in 1982. Twelve years later most PACS prototypes still do not satisfy the medical community requirements: too much emphasis has been put on technical solutions and little effort devoted to the management of images itself. A common approach to this problem is needed more than ever to allow cost-effective systems to be developed. Modelling is a way to reach this objective, and the MIMOSA topic within the AIM/EurlPACS project aims at defining such a model of medical image management. This paper presents the MIMOSA approach with the three underlying constraints, i.e. genericity, implementation independence and performance. The MIMOSA group is building three interrelated models: a data model, a functional model and a dynamic model. However, in this report we focus only on the functional model, and explain how it was abstracted from various clinical scenarios in the first phase of the project. The availability level concept is introduced as a customizable and implementation independent solution to the problem of managing the delay of access to the information. The so-called contextual diagram and the acquisition of a new examination which are two representative parts of the model are detailed. The validation aspects and the relationships to projects working on the management of patient records are addressed as a conclusion.

Computer Systems↗

Phosphoproteomics by mass spectrometry and classical protein chemistry approaches.

The general fields of biological sciences have seen phenomenal transformations in the past two decades at the level of data acquisition, understanding biological processes, and technological developments. Those advances have been made partly because of the advent of molecular biology techniques (which led to genomics) coupled to the advances made in mass spectrometry (MS) to provide the current capabilities and developments in proteomics. However, our current knowledge that approximately 30,000 human genes may code for up to 1 million or more proteins disengage the interface between the genome sequence database algorithms and MS to generate a major interest in independent de novo MS/MS sequence determination. Significant progress has been made in this area through procedures to covalently modify peptide N- and C-terminal amino-acids by sulfonation and guanidination to permit rapid de novo sequence determination by MS/MS analysis. A number of strategies that have been developed to perform qualitative and quantitative proteomics range from 2D-gel electrophoresis, affinity tag reagents, and stable-isotope labeling. Those procedures, combined with MS/MS peptide sequence analysis at the subpicomole level, permit the rapid and effective identification and quantification of a large number of proteins within a given biological sample. The identification of proteins per se, however, is not always sufficient to interpret biological function because many of the naturally occurring proteins are post-translationally modified. One such modification is protein phosphorylation, which regulates a large array of cellular biochemical pathways of the biological system. Traditionally, the study of phosphoprotein structure-function relationships involved classical protein chemistry approaches that required protein purification, peptide mapping, and the identification of the phosphorylated peptide regions and sites by N-terminal sequence analysis. Recent advances made in mass spectrometry have clearly revolutionized the studies of phosphoprotein biochemistry, and include the development of specific strategies to preferentially enrich phosphoproteins by covalent-modifications that incorporate affinity tags that use the physicochemical properties of phosphoaminoacids. The phosphoserine/phosphothreonine-containing proteins/peptides are derivatized under base-catalyzed conditions by thiol agents; mono- and di-thiol reagents both have been used in such studies. The thiol agent may have: (i) an affinity tag for protein enrichment; (ii) stable-isotopic variants for relative quantitation; or (iii) a combination of the moieties in (i) and (ii). These strategies and techniques, together with others, are reviewed, including their practical application to the study of phosphoprotein biochemistry and structure-function. The consensus of how classical protein chemistry and current MS technology overlap into special case of proteomics, namely "phosphoproteomics," will be discussed.

Amino Acid Sequence↗

Assessment of spatial learning abilities of mice in a new circular maze.

In the present study, we tested the spatial learning behavior of four different mouse strains (129/Sv, BALB/c, C57BL and Swiss) in a newly developed circular maze. The maze was based on the circular Barnes maze, which was initially developed for rats. Since mice do not readily enter holes in floor, additional reinforcers (positive and negative) or pretraining procedures have been used to train the animals. Because these methods are not always desirable, we examined whether mice are more willing to enter escape holes (12), which were located in the rim of the apparatus. C57BL mice appeared to improve their performance on three different measures of spatial learning: latency to find escape hole, distance to escape hole and errors (visit to other holes). The other strains also improved their performance although this was only seen for one parameter (i.e. 129/Sv and BALB/c on latency, and Swiss on distance). When the animals were trained to find another location, it was found that only the performance of the C57BL mice was transiently impaired. The C57BL mice were also very efficient in improving their performance in a repeated acquisition paradigm (six trials per day on four successive days). Applying a probe trial procedure, a clear preference for the goal location was found. These findings indicate that these mice used a spatial search strategy. Although this circular maze can be used as an additional tool to assess spatial learning in (genetically modified) mice, it is noted that strain differences in spatial learning seem to be independent of task. Further, our data with different strains indicate that different measures of behavior should be evaluated to assess the spatial learning performance of mice.

Analysis of Variance↗

Use of vector processing to search the Cambridge Structural Database.

The Cambridge Structural Database (CSD) is a vast numerical resource of crystallographic data. The January 1989 release contains over 70,000 entries, and the data acquisition rate currently increases about 15% per annum. To be able to provide adequate response times for interactive data retrieval, using the new (1988) CSD file format, a vectorized search procedure has been developed as a modification of the CSD program QUEST. This procedure employs the pipelined vector facilities of the CONVEX C120 system to perform bitscreen logic, resulting in response times for arbitrary queries in the order of seconds, almost independent of the size of the database.

Computer Systems↗

The quality of evidence in health informatics: how did the quality of healthcare IT evaluation publications develop from 1982 to 2005?

OBJECTIVE: To obtain an overview of study designs and study methods used in research evaluating IT in health care, to present a list of quality criteria by which all kinds of reported evaluation studies on IT systems in health care can be assessed, and to assess the quality of reported evaluation studies on IT in health care and its development over time (1982-2005). METHODS: A generic 10-item list of quality indicators was developed based on existing literature on quality of medical and medical informatics publications. It is applicable to all kind of IT evaluation papers and not restricted to randomized controlled trials. One hundred and twenty explanatory papers evaluating the effects of an IT system in health care published between 1982 and 2005 were randomly selected from PubMed, the study designs and study methods were extracted, and the quality indicators were used to assess the quality of each paper by two independent raters. RESULTS: The inter-rater variability of scoring the 10 quality indicators as assessed by a pre-test with nine papers was good (K=0.87). There was a trend towards more multi-centre studies and authors coming more frequently from various departments. About 70% of the studies used a design other than a randomized controlled trial (RCT). Forty percent of the studies combined at least two different data acquisition methods. The quality of IT evaluation papers, as defined by the quality indicators, was only slightly improving in time (Spearman correlation coefficient [rs]=0.19). The quality of RCTs publications was significantly higher than the quality of non-RCT studies (p<0.001). CONCLUSION: The continuous and dominant number of non-RCT studies reflects the various approaches applicable to evaluate IT systems in health care. Despite the increasing discussion on evidence-based health informatics, the quality of published evaluation studies on IT interventions in health care is still insufficient in some aspects. Journal editors and referees should take care that reports of evaluation on IT systems contain all aspects needed for a sufficient understanding and reproducibility of a paper. Publication guidelines should be developed to support more complete and better publications of IT evaluation papers.

Europe↗

Phi-analysis at the experimental limits: mechanism of beta-hairpin formation.

The 37-residue Formin-binding protein, FBP28, is a canonical three-stranded beta-sheet WW domain. Because of its small size, it is so insensitive to chemical denaturation that it is barely possible to determine accurately a denaturation curve, as the transition spans 0-7 M guanidinium hydrochloride (GdmCl). It is also only marginally stable, with a free energy of denaturation of just 2.3 kcal/mol at 10 degrees Celsius so only small changes in energy upon mutation can be tolerated. But these properties and relaxation times for folding of 25 micros-400 micros conspire to allow the rapid acquisition of accurate and reproducible kinetic data for Phi-analysis using classical temperature-jump methods. The transition state for folding is highly polarized with some regions having Phi-values of 0 and others 1, as readily seen in chevron plots, with Phi-values of 0 having the refolding arms overlaying and those of 1 the unfolding arms superimposable. Good agreement is seen with transition state structures identified from independent molecular dynamics (MD) simulations at 60, 75, and 100 degrees Celsius, which allows us to explore further the details of the folding and unfolding pathway of FBP28. The first beta-turn is near native-like in the transition state for folding (experimental) and unfolding (MD and experiment). The simulations show that there are transient contacts between the aromatic side-chains of the beta-strands in the denatured state and that these interactions provide the driving force for folding of the first beta-hairpin of this three-stranded sheet. Only after the backbone hydrogen bonds are formed between beta1 and beta2 does a hydrogen bond form to stabilize the intervening turn, or the first beta-turn.

Amino Acid Sequence↗

Adjusting bone mass for differences in projected bone area and other confounding variables: an allometric perspective.

The traditional method of assessing bone mineral density (BMD; given by bone mineral content [BMC] divided by projected bone area [Ap], BMD = BMC/Ap) has come under strong criticism by various authors. Their criticism being that the projected bone "area" (Ap) will systematically underestimate the skeletal bone "volume" of taller subjects. To reduce the confounding effects of bone size, an alternative ratio has been proposed called bone mineral apparent density [BMAD = BMC/(Ap)3/2]. However, bone size is not the only confounding variable associated with BMC. Others include age, sex, body size, and maturation. To assess the dimensional relationship between BMC and projected bone area, independent of other confounding variables, we proposed and fitted a proportional allometric model to the BMC data of the L2-L4 vertebrae from a previously published study. The projected bone area exponents were greater than unity for both boys (1.43) and girls (1.02), but only the boy's fitted exponent was not different from that predicted by geometric similarity (1.5). Based on these exponents, it is not clear whether bone mass acquisition increases in proportion to the projected bone area (Ap) or an estimate of projected bone volume (Ap)3/2. However, by adopting the proposed methods, the analysis will automatically adjust BMC for differences in projected bone size and other confounding variables for the particular population being studied. Hence, the necessity to speculate as to the theoretical value of the exponent of Ap, although interesting, becomes redundant.

Adolescent↗

Determination of the attenuation map in emission tomography.

Reliable attenuation correction methods for quantitative emission CT (ECT) require accurate delineation of the body contour and often necessitate knowledge of internal anatomic structure. Two broad classes of methods have been used to calculate the attenuation map: transmission-less and transmission-based attenuation correction techniques. Whereas calculated attenuation correction belonging to the first class of methods is appropriate for brain studies, more adequate methods must be performed in clinical applications, where the attenuation coefficient distribution is not known a priori, and for areas of inhomogeneous attenuation such as the chest. Measured attenuation correction overcomes this problem and uses different approaches to determine this map, including transmission scanning, segmented magnetic resonance images, or appropriately scaled CT scans acquired either independently on separate or simultaneously on multimodality imaging systems. Combination of data acquired from different imagers suffers from the usual problems of working with multimodality images--namely, accurate co-registration from the different modalities and assignment of attenuation coefficients. A current trend in ECT is to use transmission scanning to reconstruct the attenuation map. Combined ECT/CT imaging is an interesting approach; however, it considerably complicates both the scanner design and the data acquisition and processing protocols. Moreover, the cost of such systems may be prohibitive for small nuclear medicine departments. A dramatic simplification could be made if the attenuation map could be obtained directly from the emission projections, without the use of a transmission scan. This is being investigated either using a statistical model of emission data or applying the consistency conditions that allow one to identify the operator of the problem and, thus, to reconstruct the attenuation map. This article presents the physical and methodologic basis of attenuation correction and summarizes recent developments in algorithms used to compute the attenuation map in ECT. Other potential applications are also discussed.

Algorithms↗

SYDESCO: a laser-video scanner for 3D scoliosis evaluations.

SYDESCO is a new 3D vision system developed for trunk surface topography. This structured light surface scanner uses the principle of triangulation-based range sensing to infer 3D shape. The complete trunk acquisition is fast (2 seconds). The accuracy of the metric data is ensured by a subpixel image detection and a calibration process, which rectifies image deformations. A preliminary study presents results on 50 children in a gymnastics school. These children, aged between eight to sixteen years, are particularly exposed to spinal deformities. An asymmetry index is calculated from the 3D data to detect the pathologic cases. These results have been compared to an independent medical diagnosis. The system results have been confirmed for 72,1% of the patients.

Child↗