Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

Analysis of unknown organic pollutants in sewage by solid-phase extraction combined with gas chromatography-mass spectrometry.

A rapid, simple, and reliable method of solid-phase extraction (SPE) combined with gas chromatography (GC)-mass spectrometry (MS) is developed for the analysis of a wide range of polarity of unknown organic pollutants in sewage. Wastewater samples are extracted by passing them through disposable C(18) cartridges, and the extracts are then analyzed by GC-MS. Different SPE parameters for ten organic compounds in the list of priority pollutants suggested by the China Environmental Protection Agency (EPA) are studied, and their breakthrough volumes are determined. Extraction recoveries for the tested compounds are greater than 60%, except the recovery of 1,2-dichloroethane is 48%. The relative standard deviations are less than 7.8% (n = 3). The developed approach is successfully applied for the identification of organic components in a sewage sample. Over 220 organic pollutants are identified, with 5 of these present in the list of priority pollutants suggested by the U.S. EPA and 4 from the list by the China EPA.

Environmental Pollutants↗

Solid-phase extraction and HPTLC determination of isoniazid and acetylisoniazid in serum. Comparison with HPLC.

A new solid-phase extraction (SPE) and quantitative determination of isoniazid (INH) and its acetyl metabolite (AcINH) in serum by high-performance thin-layer chromatography (HPTLC) is presented. Alkalized serum samples with nicotinamide as an internal standard are applied to an SPE cartridge containing a new SPE sorbent, [poly (divinylbenzene-co-N-vinylpyrrolidone )]. A simple procedure of conditioning, washing, and eluting steps is described. After evaporation of the eluates to dryness and reconstitution, one-dimensional HPTLC is performed on silica gel plates with ethyl acetate-methanol (70:30) as a mobile phase. Quantitation is done by densitometry. Convenient validation parameters are obtained (linearity, limits of detection and quantitation, precision, and accuracy) for INH and AcINH. The method is compared with a high-performance liquid chromatographic (HPLC) technique developed in the laboratory, and satisfactory correlation is found between data from the two techniques. The HPTLC method is sensitive and specific and is used to quantitate INH and AcINH in patient blood serum, and the results are compared with those obtained by HPLC.

Antitubercular Agents↗

Automated online and off-line solid-phase extraction methods for measuring isoflavones and lignans in urine.

Automated online and off-line solid-phase extraction (SPE) methods coupled to isotope dilution-high-performance liquid chromatography-tandem mass spectrometry for measuring four isoflavones (daidzein, genistein, equol, and O-desmethylangolensin) and two lignans (enterolactone and enterodiol) in urine are developed. The SPE recoveries for the online SPE method are excellent for most analytes (83-94%) and somewhat lower for enterolactone (61%). The recoveries for all analytes with the off-line SPE method are also very good (65-80%). The limit of detection is lower for the online method (0.1-0.7 ng/mL) than for the off-line method (0.4-3.3 ng/mL). Similarly, the reproducibility is generally better for the online method [coefficient of variation (CV) of 4-12%) than for the off-line method, except for enterolactone, which has a higher CV (18-19%) that is consistent with its lower online SPE recovery. Both methods are adequate for analyzing a large number of samples for epidemiological studies to assess the prevalence of human exposure to isoflavones and lignans.

Chromatography, High Pressure Liquid↗

Clinical evaluation of Toxi.Prep: a semiautomated solid-phase extraction system for screening of drugs in urine.

A prototype Toxi.Prep (TP) system that utilizes solid-phase extraction (SPE) has been developed as a method for broad-spectrum drug screening and identification of tetrahydrocannabinol (THC) metabolites in urine. TP can simultaneously extract up to seven specimens while automating the process of sample extraction, washing, and elution onto a chromatogram. TP was compared with the Toxi. Lab A (TL-A) system for extraction of basic drugs only. In a blind study, 33 distinct drugs and metabolites were detected in 55 urines over 13 runs. Of the drug occurrences, 68.8% (141 of 205) were detected on both TP and TL-A. Of the 13 runs, quinidine and quinine, nortriptyline metabolites, and diphenhydramine were noted more frequently on TP than TL-A, whereas nicotine and metabolites, morphine, and methadone metabolites were more frequently noted on TL-A. Twenty specimens were analyzed for THC metabolites. Of the cases positive for THC metabolites, 100% (16 of 16) were positive by both methods. Time and motion studies for all runs proved an overall labor reduction for extraction and spotting by approximately 40%.

Adult↗

Solid-phase extraction cleanup and liquid chromatography with ultraviolet detection of ephedrine alkaloids in herbal products.

A solid-phase extraction (SPE) cleanup and a liquid chromatographic (LC) method with UV detection is presented for analysis of up to 7 ephedrine alkaloids in herbal products. Alkaloids from herbal products are extracted with acidified buffer, isolated on a propylsulfonic acid SPE column, eluted with a high-ionic-strength buffer, and separated by LC with detection at 255 nm. LC separation is performed by isocratic elution on a YMC phenyl column with 0.1 M sodium acetate-acetic acid (pH = 4.8) containing triethyl-amine and 2% acetonitrile. Ephedrine alkaloids are completely separated in 15 min. Average recovery of 5 common alkaloids from 3 spiked matrixes is 90%, with an average relative standard deviation (RSD) of 4.4% for alkaloid spikes between 0.5 and 16 mg/g. Average quantitation of ephedrine and pseudoephedrine from 6 herbal products is 97% of declared label claims, and average quantitation of synephrine from an herbal dietary product is 85% of label claim (RSD, 3.2%). Recoveries of synephrine, norephedrine, ephedrine, pseudoephedrine, N-methylephedrine, and N-methylpseudoephedrine spiked in 4 herbal products averaged 95%. Results of ruggedness testing and of a second laboratory validation of the procedure are also presented.

Acetic Acid↗

Electrochromatographic solid-phase extraction for determination of cimetidine in serum by micellar electrokinetic capillary chromatography.

A highly effective electrochromatographic solid-phase extraction and preconcentration method is reported for the determination of cimetidine in serum in the concentration range 0.233-11.4 micrograms/ml. Preconcentrated samples were determined by micellar electrokinetic capillary chromatography while ranitidine was used as an internal standard. Sample preparation included retention of the analyte on a C18 solid-phase cartridge, followed by elution assisted by an applied voltage of 150 V. From 0.5-ml serum samples, 20-50-microliters aliquots were collected for electrophoretic analysis. Within the studied concentration range, the method was linear and provided adequate precision.

Chromatography↗

Solid-phase extraction and HPLC-UV confirmation of drugs of abuse in urine.

A series of six liquid chromatographic methods were developed to confirm the presence of six classes of drugs of abuse in urine. The chromatographic separations were performed with a reversed-phase C8 column, except in the case of morphine, which was separated on a normal phase column. Isocratic and gradient elutions, ion pair technique, and UV detection were employed. Sample pretreatment involved the extensive application of solid-phase extractions and liquid-liquid extractions on solid supports. The specificity and sensitivity enabled the confirmation of morphine, benzoylecgonine, THC-COOH, amphetamine, and methamphetamine, six barbiturates, and nine benzodiazepines screened positive by EMIT in urine.

Amphetamine↗

Exploration of coordination polymer as sorbent for flow injection solid-phase extraction on-line coupled with high-performance liquid chromatography for determination of polycyclic aromatic hydrocarbons in environmental materials.

The copper(II) isonicotinate (Cu(4-C5H4N-COO)2(H2O)4) coordination polymer was prepared, characterized and explored as sorbent for flow injection solid-phase extraction on-line coupled with high-performance liquid chromatography (HPLC) for determination of trace polycyclic aromatic hydrocarbons (PAHs) in environmental matrices. Naphthalene, phenanthrene, anthracene, fluoranthene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene and benzo(ghi)perylene with various shape, size and hydrophobicity were used as model analytes. The porosity of the coordination polymer allows these guest PAHs molecules to diffuse into the buck structure, and the shape and size of the pores lead to shape- and size-selectivity over the guests. The precolumn packed with the coordination polymer was shown to be promising for solid-phase extraction of PAHs in environmental samples with subsequent HPLC separation and UV detection. With extraction of 50 ml of sample solution, the enhancement factors for the PAHs studied ranged from 200 to 2337, depending on the shape, size and hydrophobic property of the PAHs. The detection limits (S/N = 3) of 2-14 ng l(-1) and the sample throughput of 3 samples h(-1) were obtained. The developed method was applied to the determination of trace PAHs in a certified reference material (coal fly ash) and local water samples.

Chromatography, High Pressure Liquid↗

Solid phase extraction and spectrophotometric determination of Au(III) with 5-(2-hydroxy-5-nitrophenylazo)thiorhodanine.

A new chromogenic reagent, 5-(2-hydroxy-5-nitrophenylazo)thiorhodanine (HNATR) was synthesized. A highly sensitive, selective and rapid method for the determination microg l(-1) level of Au(III) based on the rapid reaction of Au(III) with HNATR and the solid phase extraction of the colored complex with a reversed phase polymer-based C(18) cartridge have been developed. The HNATR reacted with Au(III) to form a red complex of a molar ratio 1:2 (Au(III) to HNATR) in the presence of 0.05 - 0.5 mol l(-1) of phosphoric acid solution and emulsifier-OP medium. This complex was enriched by the solid phase extraction with a polymer-based C(18) cartridge. The enrichment factor of 100 was achieved. The molar absorptivity of the complex is 1.37 x 10(5) l mol(-1) cm(-1) at 520 nm in the measured solution. The system obeys Beer's law in the range of 0.01 - 3 microg ml(-1). The relative standard deviation for eleven replicates sample of 0.5 microg l(-1) level is 2.18%. The detection limit, based on the three times of standard deviation is 0.02 microg l(-1) in the original sample. This method was applied to the determination of gold in water and ore with good results.

Journal Article↗

Determination of aryloxyphenoxypropionic acid herbicides in water using different solid-phase extraction procedures and liquid chromatography-diode array detection.

For isolation and trace enrichment of aryloxyphenoxypropionic acid (ArPP) herbicides from drinking, spring, and ground water a sensitive, robust method is presented. A 1-2 1 volume of aqueous samples was passed through a disposable solid-phase extraction cartridge, packed with 500 mg of Carbograph-1 at a flow-rate of 100 ml/min. After washing, ArPPs are selectively eluted with 8 ml of dichloromethane-methanol (80:20, v/v) with 50 mmol/1 formic acid and evaporated to dryness. The mixture was reconstituted with 250 microliters of water-acetonitrile (75:25; v/v) acidified with 0.1% trifluoroacetic acid and 100 microliters was injected into the high-performance liquid chromatography system. The ArPPs were separated via a binary gradient of water and a mixture of methanol-acetonitrile. Detection and confirmation were performed by diode array detection. Recovery of the six acid herbicides ranged between 90% and 98%. The limits of detection of ArPPs were 7-20 ng/l for drinking water and 16-36 ng/l for spring water. In terms of recovery and selectivity the effectiveness of Carbograph-1 cartridges was compared with that of LiChrolut-EN cartridges and polystyrene-divinylbenzene Empore disks. Relevant parameters such as pH and flow-rate for solid-phase extraction with divinylbenzene resins were optimized.

Chromatography, High Pressure Liquid↗

Solid phase extraction and spectrophotometric determination of silver with 2-(2-quinolylazo)-5-diethylaminophenol as chromogenic reagent.

A new chromogenic reagent, 2-(2-quinolylazo)-5-diethylaminophenol (QADEAP), was synthesized. A sensitive, selective and rapid method has been developed for the determination of microg/L level silver ion based on the rapid reaction of silver(l) with QADEAP and the solid phase extraction of the colored chelate with C18 cartridge. The QADEAP reacts with Ag(l) to form a violet chelate of a molar ratio 1:2 (silver to QADEAP) in pH 3.5-8.0. This chelate was prconcentrated by solid phase extraction with C18 cartridge. An enrichment factor of 100 was achieved. The molar absorptivity of the chelate is 1.30 x 10(5) L mol(-1) cm(-1) at 590 nm in measured solution. Beer's law is obeyed in the range of 0.01-0.6 microg/ml. The relative standard deviation for eleven replicate samples of 0.01 microg/ml is 1.15%. The detection limit is 0.02 microg/L in the original samples. This method was applied to the determination of microg/L level silver ion in water with good results.

Aminophenols↗

Molecularly imprinted solid-phase extraction of diazepam and its metabolites from hair samples.

An anti-diazepam, molecularly imprinted polymer (MIP) has been synthesized and used to extract diazepam and other benzodiazepines from hair samples via a molecularly imprinted solid-phase extraction (MISPE) protocol. Optimum retention of diazepam on the MIP columns was achieved using an apolar solvent, and the binding capacity of the polymer toward diazepam was found to be 110 ng of diazepam/mg of polymer. The recovery of a 50 ng diazepam standard spiked into blank hair was 93%, with good precision (RSD = 1.5%). The LOD and LOQ of diazepam in spiked hair samples were 0.09 and 0.14 ng/mg, respectively. The MISPE method was demonstrated to be applicable to the analysis of diazepam metabolites and other benzodiazepine drugs, in addition to diazepam itself. The application of the extraction method to postmortem hair samples yielded results that were in good agreement with the corresponding ELISA data (from blood samples) and data arising from the analysis of the same blood samples using a validated in-house SPE-LC-MS-MS method.

Benzodiazepines↗

Sensitivity enhancement for nitrophenols using cationic surfactant-modified activated carbon for solid-phase extraction surface-assisted laser desorption/ionization mass spectrometry.

Previous work has demonstrated that a combination of solid-phase extraction with surface-assisted laser desorption/ionization (SPE-SALDI) mass spectrometry can be applied to the determination of trace nitrophenols in water. An improved method to lower the detection limit of this hyphenated technique is described in this present study. Activated carbon powder is used as both the SPE adsorbent and the SALDI solid in the analysis by SPE-SALDI. The surface of the activated carbon is modified by passing an aqueous solution of a cationic surfactant through the SPE cartridge. The results demonstrate that the sensitivity for nitrophenols in the analysis by SPE-SALDI can be improved by using cationic surfactants to modify the surface of the activated carbon. The detection limit for nitrophenols is about 25 ppt based on a signal-to-noise ratio of 3 by sampling from 100 mL of solution.

Adsorption↗

Study of the solid-phase extraction of diclofenac sodium, indomethacin and phenylbutazone for their analysis in human urine by liquid chromatography.

A selective semi-automated solid-phase extraction (SPE) of the non-steroidal anti-inflammatory drugs diclofenac sodium, indomethacin and phenylbutazone from urine prior to high-performance liquid chromatography was investigated. The drugs were recovered from urine buffered at pH 5.0 using C18 Bond-Elut cartridges as solid sorbent material and mixtures of methanol-aqueous buffer or acetonitrile-aqueous buffer as washing and elution solvents. The extracts were chromatographed on a reversed-phase ODS column using 10 mM acetate buffer (pH 4.0)-acetonitrile (58:42, v/v) as the mobile phase, and the effluent from the column was monitored at 210 nm with ultraviolet detection. Absolute recoveries of the anti-inflammatory drugs within the range 0.02-1.0 microg/ml were about 85% for diclofenac and indomethacin, and 50% for phenylbutazone without any interference from endogenous compounds of the urine. The within-day and between-day repeatabilities were in all cases less than 5% and 10%, respectively. Limits of detection were 0.007 microg/ml for diclofenac sodium and indomethacin and 0.035 microg/ml for phenylbutazone, whereas limits of quantitation were 0.02 microg/ml for diclofenac and indomethacin and 0.1 microg/ml for phenylbutazone.

Anti-Inflammatory Agents, Non-Steroidal↗

Determination of a HIV protease inhibitor (DMP 450) in animal and human plasma by solid-phase extraction and high-performance liquid chromatography.

Extraction of DMP 450 from plasma was performed with C2 solid-phase extraction columns, using 0.1 M ammonium acetate in 90% methanol to elute DMP 450. The extraction recovery over the range of 10 to 10 000 ng/ml averaged 81.0, 96.2, 77.4, 95.2 and 68.0% from rat, dog, monkey, chimpanzee (25-10 000 ng/ml) and human plasma, respectively. HPLC analysis was carried out with a C18 column and a mobile phase of acetonitrile, methanol and 30 mM potassium phosphate (pH 3), the composition dependent on the type of plasma being analyzed, and monitored at a wavelength of 229 nm. Intra-day and inter-day coefficients of variation were less than 9.9 and 12.9%, respectively. Absolute differences were less than 11.5%.

Acetonitriles↗

Evaluation of automated micro solid phase extraction tips (micro-SPE) for the validation of a LC-MS/MS bioanalytical method.

Automated micro-SPE tips were successfully utilized for the determination of posaconazole in rat plasma. The bioanalytical method using micro-SPE tips was successfully qualified for routine quantitation of posaconazole over the concentration range of 10.0-10,000 ng/mL in rat EDTA plasma. Inter-assay precision, based on percent relative deviation for n=18 replicate quality controls, was < or =5.7%. Inter-assay accuracy based on n=18 replicate quality controls was +/-7.7%. Complete solid phase extraction using micro-SPE tips was demonstrated on a Tomtec liquid handler where >95% recovery for posaconazole was obtained. The micro-SPE tips had sufficient capacity to extract at least 100 microL plasma fortified with 10 microg/mL of posaconazole and the analyte could be efficiently eluted with as little as 60 microL of methanol. Of particular note is the unique ability of these micro-SPE tips to perform exhaustive solid phase extraction more commonly performed when using liquid/liquid extraction.

Animals↗

Validation of an assay for the determination of cotinine and 3-hydroxycotinine in human saliva using automated solid-phase extraction and liquid chromatography with tandem mass spectrometric detection.

The validation of a high-performance liquid chromatographic method for the simultaneous determination of low level cotinine and 3-hydroxycotinine in human saliva is reported. Analytes and deuterated internal standards were extracted from saliva samples using automated solid-phase extraction, the columns containing a hyper cross-linked styrene-divinylbenzene copolymer sorbent, and analysed by reversed-phase liquid chromatography with tandem mass spectrometric detection (LC-MS-MS). Lower limits of quantitation of 0.05 and 0.10 ng/ml for cotinine and 3-hydroxycotinine, respectively, were achieved. Intra- and inter-batch precision and accuracy values fell within +/-17% for all quality control samples, with the exception of quality control samples prepared at 0.30 ng/ml for 3-hydroxycotinine (inter-day precision 21.1%). Results from the analysis of saliva samples using this assay were consistent with subjects' self-reported environmental tobacco smoke (ETS) exposures, enhancing the applicability of cotinine as a biomarker for the assessment of low level ETS exposure.

Chromatography, High Pressure Liquid↗

Ion-pair solid-phase extractive derivatization of 4-alkylphenols with pentafluoropyridine for gas chromatography-mass spectrometry.

The ion-pair solid-phase extraction (SPE) of 4-alkylphenols followed by derivatization with pentafluoropyridine is demonstrated. Under alkaline conditions, the 4-alkylphenols could be efficiently adsorbed on a C18 SPE cartridge conditioned with an ion-pair reagent, tetra-n-hexylammonium bromide. The ion pairs, ammonium phenolates, formed on the C18 solid phase, were eluted with a solvent containing the derivatizing reagent, pentafluoropyridine, and completely derivatized during the elution. After optimization of the adsorption and derivatization, we established a method for the determination of the 4-alkylphenols in water samples. The method showed good linearity between 20 and 1000 ng (200-10,000 ng for nonylphenol). By processing 20-ml samples, the method detection limits (MDL) were in the range of 5.2-8.9 ng/l for the 4-alkylphenols (76 ng/l for nonylphenol). To evaluate its applicability to a real aqueous matrix, several river water samples were analyzed.

Gas Chromatography-Mass Spectrometry↗