Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ROSANILINE DYES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

Effects of bilayer surface charge density on molecular adsorption and transport across liposome bilayers.

Second harmonic generation (SHG) was used to study both the adsorption of malachite green (MG), a positively charged organic dye, onto liposomes of different lipid compositions, and the transport kinetics of MG across the liposome bilayer in real time. We found that the dye adsorption increased linearly with the fraction of negatively charged lipids in the bilayer. Similarly, the transport rate constant for crossing the bilayer increased linearly with the fraction of charged lipid in the bilayer.

Adsorption↗

Influence of inorganic salts on the staining reaction of eosinophil leukocyte granules by anionic dyes.

The use of salts as competing agents in staining solutions allows to evaluate to what extent ionic interactions take place between microscopical substrates and cationic or anionic dyes. We have employed this method to study the staining reaction of horse eosinophil leucocyte granules by the anionic dyes nuclear fast red, naphthol yellow S, eosin Y, indigocarmin, acid fuchsin, alizarin red S, orange G, and Evans blue in the presence of NaCl (from 0.015 to 2 mol/l). Different values of "minimal electrolyte concentration" (the least amount of salt which reduces the staining intensity) were found for these dyes. Comparative observations using ammonium sulphate as competing salt showed that it is less effective than NaCl. Staining of eosinophil granules by anionic dyes could be not suppressed at 2 mol/l NaCl, which indicates that in addition to electrostatic forces, other non-ionic interactions are also responsible for some staining reaction of these acidophilic structures.

Ammonium Sulfate↗

Lymphatic mapping in early stage breast cancer: comparison between periareolar and subdermal injection.

The combination of preoperative lymphatic mapping with intra-operative probe detection is becoming the standard procedure for identifying tumour lymphatic spread at the time of initial treatment in breast cancer. There are a number of identification techniques for sentinel lymph nodes, but the concordance of the results of a sentinel lymph node biopsy with axillary lymph node dissection did not vary significantly among them. Periareolar (p.a.) injection of tracer is a new procedure specifically studied to overcome some limitations of other techniques; in two groups of patients with early breast cancer we compared the periareolar with the subdermal technique. One hundred and fifty biopsy proven breast cancer patients were consecutively enrolled in this study. This population was divided into two groups: (1) group A, including 100 cancers; lymphatic mapping was performed by s.d. injection of both blue dye and radiotracer; and (2) group B, including 50 cancers; lymphatic mapping was performed with a combination of blue dye injected p.a. and radiotracer injected s.d. For group A, with both techniques we identified one or more SLNs in 100/100 tumours; blue dye detected the SLNs in 99/100 cancers (99%), lymphoscintigraphy in 93/100 cancers (93%). The concordance rate was 92%. For group B, with both techniques we identified one or more SLNs in 49/50 cancers (98%); blue dye detected the SLNs in 48/50, lymphoscintigraphy in 46/50 cancers (92%). The concordance rate was 92%. In the present study p.a. and s.d. injection of blue dye give similar and comparable results. The periareolar technique is simpler and has several advantages over the subdermal technique.

Administration, Cutaneous↗

Carbon dye staining of sentinel lymph nodes facilitates microstaging of colon cancer patients.

BACKGROUND: Carbon dye, when peritumourally injected, permanently marks the drainage site of sentinel lymph nodes (SLN). The objective of the current study was to evaluate whether the use of carbon dye facilitated the detection of small nodal tumour infiltrates in colon cancer patients. METHODS: In a prospective trial, 19 patients underwent open, oncological resections of localized colon cancer and SLN procedure according to a standardized protocol. Isosulfan blue 1% and sterile filtered carbon dye (mixed 1:1) were injected into the subserosa circumferentially around the tumour. Lymph nodes staining blue were marked as SLN. Serial sections of each SLN were stained with hematoxylin and eosin (H&E) and with the pancytokeratin marker AE1/AE3. The intranodal presence and site of carbon particles were noted and compared with the location of possible tumour infiltrates. RESULTS: Identification of at least one SLN was successful in 18 patients (identification rate 95%). Four patients (22%) were pN+, 11 (61%) were pN0(i-). Three patients (17%) were upstaged from pN0(i-) to pN0(i+) as isolated tumour cells were detected in their SLN: in two (11%) of the three patients, carbon dye and isolated tumour cells were found in the same nodal compartment, hence facilitating the recognition of isolated tumour cells by the pathologist. CONCLUSION: The use of carbon dye in the SLN procedure for colon cancer may facilitate the detection of small nodal tumour infiltrates.

Aged↗

[lymphatic Mapping and Sentinel Lymph Node Biopsy in patients with Breast Cancer ].

UNLABELLED: Axillary lymphadenectomy is the standard of care in breast cancer patients. Lymphatic mapping has arisen as an alternative offering less morbidity. OBJECTIVE: To determine the success rate of subareolar blue dye injection (SM) in sentinel node (SN) biopsy and its value in axillary staging. METHODS: 62 stages I and II breast cancer patients without palpable axillary nodes received subareolar injection of blue dye; an intraoperative study of the SN was carried out. Axillary lymphadenectomy was carried out in all patients. Sensitivity, specificity, positive predictive value, and negative predictive value were measured. RESULTS: In 58/62 patients (93.5%), SN was identified; 19/58(32%) patients had nodal metastases, 18 were identified in intraoperative study, and only one false negative; 12/18 patients showed metastasis in other axillary nodes (66%), in 6 (27%) the only metastasis site was SN. Sensitivity/specificity of the SN was 92.8 and 88.6%, respectively. Positive predictive value is 72.2% and negative predictive value is 97.5% CONCLUSION: SAI of blue dye allows identification of SN in 93.5%; with high sensitivity. SN negative predictive value is 97.5% in this study.

Axilla↗

Particle beam liquid chromatography-mass spectrometry of triphenylmethane dyes: application to confirmation of malachite green in incurred catfish tissue.

Eight triphenylmethane dyes (malachite green, leucomalachite green, gentian violet, leucogentian violet, brilliant green, pentamethyl gentian violet, N',N'-tetramethyl gentian violet and N',N"-tetramethyl gentian violet) have been characterized by particle beam liquid chromatography-mass spectrometry. The electron ionization spectra obtained of these dyes by this technique exhibit similar fragmentation, with the formation of phenyl and substituted phenyl radicals, and loss of alkyl groups from the amines. It was observed that the six cationic dyes are reduced in the mass spectrometer source to form the corresponding leuco compounds. This technique was evaluated for the confirmation of malachite green and leucomalachite green in incurred catfish (Ictalurus punctatus) muscle tissue.

Animals↗

The role of sentinel lymph node biopsy with blue dye alone in breast cancer patients with excisional biopsy.

PURPOSE: Sentinel lymph node biopsy (SLNB) appears to offer an excellent alternative method to routine axillary lymph node dissection for staging patients with breast cancer. The aim of this study is to evaluate the effect of excisional biopsy on identification and false negative rate of sentinel lymph node biopsy with blue dye alone in breast cancer patients with clinically negative axilla. MATERIAL AND METHODS: From March 1998 to March 2003, 266 consecutive sentinel lymph node biopsies (SLNB) were performed using isosulfan blue dye alone. Patients were divided into two groups. One hundred and four patients (39.1%) had previously undergone an excisional biopsy (Group I); in 162 patients (60.9%), pre-operative diagnosis was obtained by either fine-needle aspiration biopsy (FNAB) or core biopsy (Group II). Following sentinel lymph node biopsy, all patients had axillary lymph node dissection (ALND). Data concerning patients, sentinel lymph nodes and the status of the axilla were collected and compared using Fisher's exact test. A p value of less than 0.05 was considered statistically significant. RESULTS: The sentinel lymph node was successfully identified by blue dye in 94.3% (251/266) of patients. Mean lymph nodes removed from the axilla was 19 (range 11-36) and the mean number of sentinel nodes was 2 (range 1-5). The identification and false negative rate were unrelated to size, type or location of the tumour, or a previous surgical biopsy. CONCLUSIONS: SLNB with blue dye for evaluation of the axilla is a rapid and accurate technique that provides increased efficacy in the detection of lymphatic metastasis when careful pathologic evaluation with serial sections is performed. The risk-benefit analysis of lymphatic mapping with blue dye provides improvement in staging, with reduced morbidity and hospital stay, and the elimination of general anaesthesia. The technique may also be used safely and accurately in breast cancer patients with excisional biopsy.

Biopsy, Needle↗

Vital dye is enough for inguinal sentinel lymph node biopsy in melanoma patients.

PURPOSE: The importance of gamma probe detection (GPD) combined with vital dye for sentinel node (SN) biopsy is well accepted. We evaluated the efficacy of patent blue dye (PBD) in identifying inguinal SN. METHODS: Ninety-four cutaneous melanoma patients with inferior extremity lesions were submitted to SNB according to a established protocol. Patients were randomized in two groups: Blue group, where SN was identified by PPD and Probe group, where SN was identified by GPD. The median age was 44.2 years and median Breslow thickness was 2.1 mm. Preoperative lymphoscintigraphy, lymphatic mapping with PBD and intra-operative GPD was performed on all patients. Histological examination of SN consisted of hematoxylin-eosin and immunohistochemical staining. If micrometastases were present complete lymphadenectomy was performed. The SN was considered as identified by PBD if it was blue and identified by GPD if it demonstrated at least ten times greater radioactivity than background. RESULTS: It was explored 94 inguinal lymphatic basins, 145 SN were excised (70 guided primarily by blue dye and 75 guided primarily by probe). All SN identified by preoperative lymphoscintigraphy were excised. In the Blue group PPD identified all SN and all of them were hot. In the Probe group all SN were identified by probe and were blue. The coincidence of PPD and GPD was 100%. CONCLUSION: Patent blue dye is enough to identify superficial inguinal SN in cutaneous melanoma.

Adolescent↗

Sentinel lymph node mapping of breast cancer: a case-control study of methylene blue tracer compared to isosulfan blue.

Isosulfan blue has been traditionally used as a tracer to map the lymphatic system during identification of the sentinel lymph node. However, allergic reactions may be life threatening. We compared the efficacy of methylene blue dye as a tracer for sentinel lymph node biopsy to isosulfan blue dye. In an analysis of 164 cases, there was no clinical or statistically significant difference in the success rate of sentinel node biopsy (P = 0.22), the number of blue sentinel nodes harvested (P = 0.46), the concordance with radioactive sentinel nodes (P = 0.92), or the incidence of metastases (P = 0.87) when methylene blue tracer was compared to isosulfan blue. No adverse reaction to either blue dye was observed. In conclusion, intraparenchymal injection of methylene blue dye is a reliable tracer for the lymphatic system and nodal identification during sentinel node mapping for breast cancer. It is safe, inexpensive, and readily available.

Adult↗

Coomassie brilliant blue R-250 as a highly sensitive pre-stain for immediate visualization of human serum proteins on polyacrylamide gel disc electrophoresis and raising monospecific antibodies.

We hereby describe electrophoretic analysis of normal human serum pre-stained with Coomassie Brilliant Blue R-250 (CBB). The proposed method was optimized by studying as many as 450 disc electrophoretic separations and 30 variables. The method when compared with the post-electrophoretic staining by Amido Black (AB) revealed that the pre-stained discs were intensely well defined and resolved within 2 hours with a transparent gel. Gels stained with AB, despite a prolonged destaining, showed a residual dye retention making identification of the faint components difficult. Protein eluted from the CBB pre-stained gels retained its purity and immunoreactivity and conjugates of the two prototype proteins namely the albumin and the transferrin produced high-titre monospecific antisera in immunized rabbits.

Amido Black↗

Complementarity of blue dye and isotope in sentinel node localization for breast cancer: univariate and multivariate analysis of 966 procedures.

BACKGROUND: The hypothesis that sentinel lymph node (SLN) mapping in breast cancer patients is optimized by combining blue dye and isotope is reasonable and intuitive. Despite this, few studies examine in detail the factors contributing to the success of these techniques, either individually or in combination. METHODS: During a time period of 21/2 years, 1000 consecutive patients at Memorial Sloan-Kettering Cancer Center had SLN mapping performed by using both blue dye and isotope, with preoperative lymphoscintigraphy (LSG). Among the 966 patients with invasive cancer, 12 variables were examined for their correlation with the success of SLN localization by blue dye, by isotope, and by the combined method, using univariate and multivariate models. RESULTS: By univariate analysis, blue dye success was more frequent in association with: a positive LSG (P = .02), age < or = 60 (P < .0005), a previous surgical biopsy (P = .03), and an outer quadrant tumor (P < .0005). Isotope success was more frequent with a positive LSG (P < .0005), age < or = 60 (P = .004), and intradermal isotope injection (P < .0005). Combined (dye and/or isotope) success was more frequent when there was a positive LSG (P < .0005), age < or = 60 (P = .006) and intradermal isotope injection (P < .0005). In multivariate analysis, blue dye success remained uniquely associated with outer quadrant tumor location (P < .0005), and isotope success was uniquely associated with intradermal isotope injection (P = .012). Combined success was more frequent with a positive LSG (P < .0005), age < or = 60 (P = .033), and intradermal isotope injection (P = .003). CONCLUSIONS: The five variables associated with successful SLN localization by blue dye or by isotope overlap but are not identical. Only three of these, intradermal isotope injection, a positive LSG, and age < 60, predicted success by the dye-isotope combination in the multivariate model. Dye and isotope complement each other, and SLN biopsy for breast cancer should use both.

Breast Neoplasms↗

Isolation of a component from commercial coomassie brilliant blue R-250 that stains rubrophilin and other proteins red on polyacrylamide gels.

Commercially available Coomassie Brilliant Blue R-250 (C.I. 42660) is a popular and useful dye that stains most proteins blue on polyacrylamide gels. Some proteins from brain (rubrophilin), collagens, histones and parotid gland proteins are distinctly red when stained with Coomassie Blue. Commonly used Coomassie Brilliant Blue R-250 preparations may contain more than 30 distinct colored and fluorescent components that can be separated on silica gel chromatographic columns. A specific component has been isolated on silica gel columns that stains rubrophilin and other proline-rich proteins a reddish color. Fast atom bombardment mass spectrometry of the isolated rubrophilin staining principle indicates a molecular weight of 634 as compared to 826 for the major dye in the original Coomassie Brilliant Blue R-250. Infrared spectrometry is consistent with a difference between the rubrophilin staining principle and Coomassie Brilliant Blue R-250 of a toluene sulfonic acid residue.

Acrylic Resins↗

Intradermal radioisotope is superior to peritumoral blue dye or radioisotope in identifying breast cancer sentinel nodes.

BACKGROUND: Sentinel lymph node (SLN) mapping and biopsy have emerged as the technique of choice for axillary staging of breast cancer. Several methods have been developed to identify SLNs, including peritumoral or intradermal injection of isosulfan blue dye or technetium sulfur colloid (TSC). We hypothesize that intradermal TSC is the optimal mapping technique and can be used alone to identify SLNs. STUDY DESIGN: From March 1997 through January 2001, 180 women with T1 and T2 invasive breast cancer and clinically negative axilla underwent SLN mapping and biopsy. Peritumoral TSC was injected in 74 patients, 62 of whom also received peritumoral blue dye. Intradermal TSC (above tumor) was performed in 94 patients, 76 of whom also received peritumoral blue dye. Technetium-rich nodes were identified intraoperatively using a hand-held gamma probe and blue nodes were identified visually. Hematoxylin- and eosin-stained SLN sections were examined by light microscopy for breast cancer metastases. RESULTS: Overall, the SLN mapping procedures were successful in 91% of patients. Peritumoral and intradermal TSC were successful in identifying SLNs in 78% and 97% of patients, respectively. Peritumorally injected isosulfan blue was successful in identifying 83% of SLNs. Intradermal TSC was found to be superior to peritumoral TSC and peritumoral blue dye in identifying SLNs (p = 0.00094, chi-squared, and p = 0.020, ANOVA). CONCLUSIONS: SLN mapping by intradermal TSC has a significantly higher success rate than peritumoral TSC or blue dye. There was minimal benefit in identifying additional SLNs with addition of peritumoral blue dye to intradermal TSC. So, SLN mapping and biopsy using intradermal-injected TSC can be used alone to effectively stage the axilla for breast cancer.

Breast Neoplasms↗

Preoperative lymph-node staining with liposomes containing patent blue violet. A clinical case report.

A case study is reported using patent blue violet entrapped in liposomes to localize lymph nodes before surgery. Liposomes containing 44 mg patent blue violet were injected into foot lymphatics of a patient due to undergo retroperitoneal staging-lymphonodectomy. Lymph nodes were readily visualized and removed, and urine and serum was collected for assay of the dye. The maximum concentration of patent blue violet in serum was 2.7 micrograms mL-1, 1.5 h after the termination of the injection, almost no dye was detectable by the time of the operation 24 h later. In the first urine sample (2 h after the termination of the injection) the concentration of patent blue violet was 1.3 micrograms mL-1, and subsequently diminished, with the last urine sample to contain detectable dye being collected 20 h later. A total of 0.8 mg dye (2% of the injected amount) was excreted in the urine suggesting 10% of the circulating amount of dye was renally excreted. Endolymphatic injection of patent blue violet simplifies the often difficult process of finding the lymph nodes and additionally reduces side-effects. All surgery cases demanding a radical lymphonodectomy may profit, including testicular or bladder cancers and many gynaecological tumours.

Adult↗

Acridine orange-methyl green fluorescent staining of nucleoli.

The staining of nucleoli with the fluorescent dye acridine orange following by counter-staining with methyl green differentially stained nucleoli in both plant and animal cells. The nucleoli fluoresced as bright structures highlighted against the quenched fluorescence of the chromatin. This technique provides a simple and highly reproducible method for differential staining of nucleoli.

Acridine Orange↗

Comparison of Coomassie Brilliant Blue protein dye-binding assays for determination of urinary protein concentration.

We investigated the influence of assay protocol upon results of Coomassie Brilliant Blue protein dye-binding assays for urinary protein. Sensitivity and working range for, and linearity of response (including dilution dependence) of, three standard assays and four micro assays to bovine albumin, gamma-globulin, and urine are compared. The Read and Northcote standard assay (Anal Biochem 1981; 116:53-64) appears to be the method of choice.

Humans↗

Improved sentinel lymph node localization in patients with primary melanoma with the use of radiolabeled colloid.

BACKGROUND: The purpose of this study was to determine whether the sentinel lymph node (SLN) localization technique, which uses blue dye and 99mTc-labeled sulfur colloid, provides advantages over blue dye alone in the management of patients with stages I and II cutaneous melanoma. METHODS: The records of 626 consecutive patients with melanoma who underwent lymphatic mapping and SLN biopsy between 1991 and 1997 at the M.D. Anderson Cancer Center were reviewed. Lymphatic mapping was performed with isosulfan blue dye alone (n = 252) or in combination with 99mTc-labeled sulfur colloid accompanied by a hand-held gamma probe (n = 374). SLNs were defined as those that stained blue or demonstrated increased focal radiotracer uptake. RESULTS: SLN identification rates improved from 87% (dye alone) to 99% (dye and colloid) (P < .0001) with the combined technique in all anatomic sites examined. The mean number of SLNs harvested from each basin was significantly greater in the patients mapped with dye and colloid (1.74 vs 1.31; P < .0001). Occult metastatic disease was identified in 17.5% of all patients and did not significantly differ between groups. In 92% of patients who had at least one positive SLN and were mapped with both agents, lymphatic metastases were identified in the SLN that contained the greatest radiotracer uptake. CONCLUSIONS: SLN identification is enhanced by the addition of radiolabeled sulfur colloid and intraoperative use of the hand-held gamma probe and may identify SLNs missed by the blue dye alone. These data support the combined use of radiolabeled sulfur colloid and blue dye in lymphatic mapping procedures to improve the nodal staging of stages I and II melanoma.

Adolescent↗