Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

A comparison of magnetic resonance imaging, sonography, and radiography of the hand in patients with early rheumatoid arthritis.

OBJECTIVE: As therapy for rheumatoid arthritis (RA) becomes more effective, more sensitive imaging methods are required to assess disease activity and joint damage. We compared magnetic resonance imaging (MRI), sonography, and radiography for assessment of disease activity for the detection of bony erosions. METHODS: Forty-six patients with newly diagnosed RA (onset within 2 years) received clinical and laboratory assessment followed by radiographs, sonography, and MRI of the right hand at baseline and at 6 months according to a standardized protocol. We determined the presence of edema, synovitis, effusions, tendon fluid, tendon thickening, and size in the same way by MRI and sonography. The intra- and interreader reliability of MRI and radiographs and predictors of MRI erosions at 6 month followup were also examined. RESULTS: At baseline, 39 (85%), 14 (30%), and 17 (37%) patients had erosions identified on MRI, sonography, and radiography, respectively. Over time, the percentage of patients with erosions increased to 91% for MRI, 41% for sonography, and 48% for radiography. The absolute number of erosions increased from 177 to 239 erosions for MRI, from 30 to 43 for sonography, and from 38 to 73 for radiographs. The intra- and interreader reliability for the assessment of erosions and synovitis on MRI was acceptable (intrareader ICC of 0.60 and 0.90; interreader ICC of 0.77 and 0.89, respectively). CONCLUSION: MRI appears to be the most sensitive modality for erosive disease compared with sonography and radiography. Sonography detected more joint and tendon sheath effusions than MRI in this study and therefore may have a role in the assessment of disease activity.

Adult↗

[To the ways of the most reasonable implementation of digital radiography into the practical public health of the Russian Federation].

The main idea of the authors' paper is to propose the most reasonable way of actively introducing the digital principle into the traditional roentgenological section of radiation diagnosis. For this, a luminophore digital radiography system has been chosen. The authors of the paper give a full-scale assessment and appropriate recommendations for its use. The paper essentially discusses the entire complex of matters that permit assessment whether its sound use is possible in regional and municipal health care systems. This is both a section devoted to a dose load, by making a comparative assessment of luminophore radiography and "the green system" and a study of different clinical diseases (456 cases). In their study, the authors have applied an original principle in the formation of an image obtained and some other approaches in order to make a comprehensive assessment of this method. In the authors' opinion, luminophore radiography has a variety of advantages. Firstly, this technique can be simultaneously applied to several nondigital apparatuses, including those available in the ward and it shows a rather diagnostic effectiveness and economic profitability, yields a qualitative image of varying density tissues upon single exposure, and has some other capacities of the CR system as a digital technique. All this things considered, the authors consider that luminophore radiography may be one of the main ways of introducing a digital technique into the conventional roentgenological section of radiation diagnosis at the level of regional and municipal heath care systems.

Delivery of Health Care, Integrated↗

Radiography student perceptions of clinical stressors.

CONTEXT: Technological change and the increasingly rapid pace of life in the United States and globally have contributed to increased levels of stress and burnout experienced by workers and their families. Although studies are available on the levels of workplace stress and burnout affecting radiographers, little to no research has been conducted to assess the stressors encountered by radiography students in the clinical environment. OBJECTIVE: This study was designed to pinpoint the primary sources of stress for radiography students and to determine the most effective measures to alleviate the stress that students experience in the clinical environment. It also sought to identify the clinical activities and practices that enhance learning. METHODS: A convenience sample of radiography students attending an Association of Collegiate Educators in Radiologic Technology meeting was surveyed. Students were asked to rank their greatest stressors in the clinical environment, the most desired qualities in a clinical instructor and clinical environment, and the clinical practices and activities that best enhance their learning. Descriptive statistics were used to report the results. RESULTS: Data were collected for 82 first-year and second-year students. Students identified 7 primary clinical stressors: fear of making a mistake/repeat, feeling unprepared/inexperienced, intimidation by staff and by instructors, difficult/critical patients, hurtful criticism, too much supervision and negative responses to questions/requests for help. Students indicated that more frequent feedback, availability of the clinical instructor and other staff, assurance that mistakes happen and the opportunity to make mistakes were clinical practices that eased stress. The majority of students cited hands-on learning and repetition as the clinical activities that most reinforced their learning. Summary Radiography students in this survey experience some of the same clinical stressors as radiographers and other allied health workers, although the source of stress may be different. Factors that promote an optimum clinical learning environment for students include instructor availability, opportunities to practice skills and make mistakes, frequent performance feedback and assurance that mistakes happen.

Attitude of Health Personnel↗

Esophageal motor function evaluated by scintigraphy, video-radiography and manometry in diabetic patients.

Prolonged esophageal scintigraphic transit time is frequent in diabetic patients and is related to autonomic neuropathy. In this study, esophageal scintigraphic transit time was correlated to esophageal motor function as evaluated by video-radiography and manometry in 13 diabetic patients. An abnormal scintigraphic transit time (greater than 15 s) occurred in 6 patients. All patients with abnormal transit time showed abnormal results at video-radiography (n = 4) and/or manometry (n = 5), which were observed in only 2 of 7 patients with normal transit time (both with abnormal video-radiography and manometry). A prolonged scintigraphic transit appears reliable as an indicator of disturbed esophageal smooth muscle function since it is well correlated with abnormalities shown by a combination of video-radiography and manometry.

Adult↗

Large-image intensifier photofluorography and conventional radiography in pulmonary emphysema. Correlation with computed tomography.

Large-screen image intensifier (II) photofluorography was compared with full-size screen-film chest radiography in the diagnosis of pulmonary emphysema in 84 patients. Photospot films and conventional radiographs were interpreted independently by three radiologists. Computed tomography (CT) was used as an independent reference technique, and diagnostic performance of chest radiography in various CT patterns of emphysema was evaluated. The difference in diagnostic sensitivity for emphysema in favor of conventional chest radiography over photofluorography (0.65 versus 0.56) was statistically significant (p less than 0.05). Specificity of the imaging modalities was equal: 0.78 in full-size films and 0.77 in photospot films. All CT patterns of emphysema had great false negative response rates in chest radiography, which is an inaccurate technique for the diagnosis of emphysema. CT is required for reliable radiologic evaluation of emphysema.

Emphysema↗

[Digital radiography--methods and clinical application].

The term "Digital Radiography" covers all x-ray techniques which produce a projected image with the help of digital imaging techniques, which are very similar to a conventional x-ray film image. The advantage of "Digital Radiography" is the possibility of digital image processing, like the subtraction technique, the selective material filtering technique and the quantitative image plotting technique. With the equipments now in use, the digital projected image is produced by the line or on an even level. One example of the in-line projected image is the so-called "topogram", produced via computed tomography equipment. With the help of an x-ray video chain, it is possible to produce digital images on an even level. This technique is used, for example, for "digital video subtraction angiography" (DVSA). Today, digital radiography is clinically used only in the "DVSA" and the "topogram" systems. A survey of the clinical use and the improved future possibilities of digital radiography is given, and the special features of the method are discussed.

Analog-Digital Conversion↗

Comparison of radiography, magnetic resonance imaging, and surgical findings in dogs with elbow dysplasia.

OBJECTIVE: To describe the magnetic resonance imaging (MRI) appearance of medial coronoid process and humeral condyle lesions in dysplastic cubital joints and to compare survey radiography and MRI for evaluation of fragmented medial coronoid process (FMCP) and lesions of the medial aspect of the humeral condyle (MAHC). ANIMALS: 18 dogs with elbow dysplasia. PROCEDURE: Radiography of 22 cubital joints was performed. The 22 joints then underwent MRI. The scans were evaluated with regard to the shape and signal of the coronoid process; articular cartilage change, subchondral bone disruption of the MAHC. Surgical findings were used as the standard to calculate accuracy, sensitivity, specificity, and positive- and negative-predictive values for specific diagnosis of FMCP (free fragment) and lesions of the MAHC. RESULTS: At surgery, 31.8% of the joints had FMCP (free), 36.4% had nondisplaced unmineralized coronoid process, and 27.2% had nondisplaced mineralized coronoid process. Eleven joints had lesions of the MAHC, and wear lesions were observed in 41% of the joints. On radiography, FMCP (free) was visualized in 9% of the joints and lesions of the MAHC were observed in 23%. MRI had the highest accuracy (95.5%), sensitivity (100%), and negative-predictive value (100%) for detection of FMCP (free), and had accuracy (91%), sensitivity (87.5%), specificity (92.5%), and positive (87.5%)- and negative (92.5%)-predictive values for detection of nondisplaced unmineralized coronoid process. CONCLUSIONS AND CLINICAL RELEVANCE: Compared with radiography, MRI was useful for detection of nondisplaced unmineralized coronoid process; images consistently correlated with surgical findings. The technique is accurate and especially useful when radiographic findings are inconclusive.

Animals↗

[Diagnosis of pneumonia in long-term ventilated patients. Value of digital luminescence radiography in comparison with clinical and microbiological monitoring].

PURPOSE: Pulmonary infection is one of the most feared complications in patients receiving long-term ventilation. We evaluated prospectively the diagnostic value of daily bedside chest radiography performed as digital luminescence radiography (DLR) in comparison to clinical findings and quantitative microbial culture. MATERIAL AND METHODS: Prospective evaluation of daily bedside chest radiography (DLR) and clinical parameters such as blood count, body temperature, and microbiological monitoring (quantitative culturing, microscopy) of 20 patients receiving long-term ventilation was undertaken. Altogether 325 chest radiographs were evaluated. RESULTS: 96% of the routine radiographs showed abnormal findings. Nosocomial pneumonia was suspected in 31% of all 330 days of observation by means of clinical and microbiological findings. DLR showed correct findings in 80% of this days (right-positive interpretation); a false-positive interpretation was resulted in 16 radiographs. Most common finding in nosocomial pneumonia was an alveolar pattern with air bronchogram. Fever and leucocytosis often precede radiological evidence of pneumonia. CONCLUSION: Daily bedside chest radiography performed as DLR shows abnormal finding in a high percentage. Bedside chest radiograph is in accordance to clinical and microbiological finding of nosocomial pneumonia in 80%.

Adult↗

Comparison of computerized digital and film-screen radiography: response to variation in imaging kVp.

A controlled prospective study, in an animal model chosen to simulate portable neonatal radiography, was performed to compare the response of the Philips Computed Radiography (CR) system and conventional 200 speed film-screen (FS) to variation in imaging kVp. Acceptable images were obtained on the CR system over a very wide kVp range. In contrast the FS system produced acceptable images over a narrow kVp range. This ability suggests that the CR system should eliminate the need for repeat examinations in cases where a suboptimal kVp setting would have resulted in an unacceptable FS image. CR technology should therefore be ideally suited to portable radiography especially in situations where selection of correct exposure factors is difficult as in the neonatal nursery.

Animals↗

The integral dose in panoramic intraoral x-ray tube radiography.

A Monte Carlo computer program was developed to estimate the integral dose to the head and thyroid for panoramic intraoral x-ray tube radiography. The advantage of this computer simulation is that it is able to avoid many of the difficulties associated with low-energy and low-dose x-ray dosimetry. The calculations were made for maxillary and mandibular projections separately, using 10 kv. increments between 40 and 60 kv. The results obtained were presented in terms of the integral dose per milliampere second. Typical integral doses for a routine examination of the head are 2.1 mJ. and 8.5 microJ for the thyroid during mandibular radiography and 1.7 microJ for the thyroid during radiography of the maxilla using 55 kv. and 0.5 mAs.

Computers↗

Thyroid dose distribution in dental radiography.

The anatomic position and proven radiosensitivity of the thyroid gland make it an organ of concern in dental radiography. A calibrated thermoluminescent dosimetry system was used to investigate the absorbed dose (microGy) to the thyroid gland resultant from a minimum irradiated volume, intraoral full-mouth radiography technique with the use of rectangular collimation with a lead-backed image receptor, and conventional panoramic radiography performed with front and rear lead aprons. Use of the minimum irradiated volume technique resulted in a significantly decreased absorbed dose over the entire thyroid region ranging from 100% to 350% (p less than 0.05). Because this intraoral technique results in radiographs with greater image quality and also exposes the thyroid gland to less radiation than the panoramic, this technique may be an alternative to the panoramic procedure.

Equipment Design↗

Dose reduction in dental radiography.

All exposures to ionizing radiation for medical and dental purposes carry risks to both the patient and staff. It is now accepted practice that all exposures should be kept as low as reasonably practicable to minimize these risks. The various methods currently available for dose limitation in intraoral and panoramic radiography and their effects on image quality are considered. In intraoral radiography the use of fast (E-speed) film and rectangular collimation offer dose reductions of approximately 50 per cent and 60 per cent respectively. Constant potential X-ray units, longer focus-to-skin distances and rare-earth filtration will permit further dose reductions. In panoramic radiography the radiation dose to the patients can be reduced by up to one-eighth by combining the use of constant potential X-ray units, rare-earth intensifying screens and rare-earth filtration.

Humans↗

Determination of the resolution of a digital system for panoramic radiography based on CCD technology.

OBJECTIVES: To determine Line Spread Functions (LSFs) and Modulation Transfer Functions (MTFs) for a digital system for panoramic radiography: the Dimax I (Planmeca Oy, Helsinki, Finland) based on Charge-Coupled Device (CCD) technology. STUDY DESIGN: A test object was specially designed having a gold foil positioned vertically. Images of the gold foil created edge functions that were used to determine LSFs and MTFs. The design of the test object made it possible to move the gold foil forward and backward relative to the central plane of the image layer by means of a micrometer screw. The experiment was carried out for different object depths in 5 different regions: the anterior, the canine, the premolar, the molar, and the TMJ regions. LSFs and MTFs were calculated using specially designed software. RESULTS: The results are presented graphically. LSFs and MTFs for the central plane were essentially the same for all regions. The MTFs for different object depths in the 5 investigated regions exhibited typical characteristics of MTFs for panoramic radiography with the exception for the functions for the molar region. CONCLUSIONS: The present findings indicate that the resolution of the Dimax I CCD system is comparable to that of film-based panoramic radiography.

Bicuspid↗

A critical appraisal of "out-of-hours" radiography in a major teaching hospital.

The use of plain radiography performed outside normal working hours was studied at the Manchester Royal Infirmary to determine the costs of the service and where possible financial savings could be made. The annual cost of "out-of-hours" radiography was estimated to be in order of 250,000 pounds. During a selected 2-week period, 84% and 76% of all examinations performed on Accident and Emergency patients and inpatients, respectively, were found to be normal. Previous reports suggest that the number of radiographs requested in the Accident and Emergency department can be reduced without detriment to patients by the implementation of appropriate clinical guidelines. We consider that if similar guidelines were developed and applied to the use of out-of-hours radiography, substantial savings could be made. We estimate that in our hospital these savings could amount to 18% of the current expenditure on this service.

Appointments and Schedules↗

Comparison between panoramic and periapical radiography in the diagnosis of periodontal bone loss.

Panoramic and periapical radiography was performed on 100 patients. Five observers each registered the scores for marginal bone level, presence of bone defects and furcation involvement in the radiographs of 20 patients and the results were compared. The overall concordance in scoring the marginal bone level was high when panoramic and periapical radiography was compared. In the upper arch, 66% of the sites showed concordant scores, 31% deviated by one and 3% by two score-points. In the lower arch, 74% of sites had concordant scores, 25% deviated by one and 1% by two score-points. The panoramic radiographs more often indicated a more severe bone loss than the periapical radiographs. The concordance was related to the degree of bone loss. In sites with no bone loss the concordance was high whereas it was lower in those with severe bone loss. The concordance of the two radiographic methods for the mandibular canine, premolars and first molar was equally as high as the intra-observer overall agreement, but lowest for the mandibular central incisors and the maxillary molars. Bone defects were more easily identified by periapical radiography.

Bone Resorption↗

Comparison of direct digital and conventional radiography for the detection of proximal surface caries in the mixed dentition.

PURPOSE: The aim of this study was to compare the performance of direct digital radiography and traditional dental radiography for the detection of proximal surface dental caries in the mixed dentition. METHODS: 15 quadrants of extracted teeth, arranged from the primary canine to permanent first molar, were imaged using direct digital (Schick Technologies, Long Island City, NY, USA) and conventional films (D-speed and E-speed Plus; Eastman Kodak Co., Rochester, NY, USA). Five pediatric dentists viewed the images and scored the 270 proximal surfaces for presence of caries on a 5 point scale and extent of caries on a 4 point scale. The teeth were sectioned and viewed microscopically to determine the gold standard. Receiver operating characteristic (ROC) analysis and analysis of variance (ANOVA) were used to evaluate the viewer's performance for detecting proximal caries using the 3 different image receptor types. RESULTS: Experienced examiners were significantly more accurate in diagnosis of proximal surface caries using either D-speed or E-speed Plus films than they were using the direct digital receptor. The mean areas under the ROC curve (Az) for the viewers were 0.7595 for D-speed film, 0.7557 for E-speed Plus film, and 0.5928 for the direct digital receptor. The results also indicated that selected viewers' accuracy increased when viewing the direct digital images a second time. CONCLUSION: CCD based direct digital radiography was not as accurate as conventional film images for the purpose of diagnosing proximal surface caries in the mixed dentition. However, the results imply that with increased experience, direct digital images may be as accurate as conventional film based images for diagnosis.

Analysis of Variance↗

Optimisation of conditions of visualisation of dental crowns in dental radiography.

Digital X-ray imaging systems are an alternative to conventional intraoral radiograms. In the paper there are discussed the possibilities of application of different digital radiography tools as well as density measurements in optimization of diagnostics of pathological lesions of teeth crowns. There were analyzed 1,491 digital intraoral radiograms obtained in 985 patients in the Digora Soredex digital radiography system. On all taken X-ray pictures there were evaluated the crowns of teeth in cases of primary and secondary caries, dental fillings, internal resorption, traumatic lesions of incisors as well as the relationships between deep carietic lesions and pulp horns as well as root furcation. An attempt was made to assess the possibilities of differentiation of cervical caries and cervical burn-out. In the paper there were presented the optimal options of digital radiography software in diagnostics of the discussed pathological lesions.

Crowns↗

[Radiological assessment of pulmonary function by computed radiography with imaging plates].

The usefulness of computed radiography with imaging plates (CR) for radiological assessment of pulmonary function was studied. Visibility of intrathoracic structures on CR images was compared with that on screen-film images. Intrathoracic structures included right intermediate arterial trunk, midzonal vessels, peripheral zonal vessels, the trachea at the level of the aortic arch, and lateral margin of the spine on posteroanterior radiographs. On lateral radiographs, the pulmonary apex, upper border of the aortic arch, anterior border of the heart, anterior margin of the ascending aorta, and trachea were included. Forty-six posteroanterior and 40 lateral radiographs taken by CR and screen-film radiography were reviewed. CR was often superior in identifying intrathoracic structures. Marked superiority of CR to screen-film radiography in visualizing intrathoracic structures was found in 48% of peripheral zonal vessels, 63% of tracheas on posteroanterior images, 46% of lateral margins of the spine, and 60% of pulmonary apexes. The superiority of CR is due to the wide dynamic range of imaging plates and image-processing procedures. CR will make it easier to identify multiple intrathoracic structures for radiographic measurements. In a second experiment chest radiographs were taken in both deep inspiration and expiration phase with one-shot dual-energy subtraction technique using the CR system in five patients with chronic pulmonary emphysema showing abnormal pulmonary function and 5 patients without any airway obstruction diseases. Original CR plain chest images and bone-subtracted chest images were displayed on a CRT (TDF-500AS, Toshiba Medical, Tokyo) and X-ray densitometry was attempted utilizing digital values.(ABSTRACT TRUNCATED AT 250 WORDS)

Humans↗