Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pulse”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

Comparison of continuous versus pulsed CO2 and Nd:YAG laser-induced pulmonary parenchymal lung injury in a rabbit model.

BACKGROUND AND OBJECTIVE: Laser techniques have recently been described for treatment of patients with emphysema and bullous lung disease. Laser exposure of the pulmonary parenchyma during these procedures is complicated by laser-induced lung injury with substantial associated morbidity. Animal investigations are needed to develop methods that reduce lung injury. We hypothesized that the depth of injury could be reduced by pulsing laser exposures, with the goal of limiting thermal effects to more superficial tissue levels. In this study, we compared acute and chronic histologic injury resulting from pulsed- versus continuous-mode CO2 and Nd:YAG laser pulmonary parenchymal exposures in rabbits. STUDY DESIGN/MATERIALS AND METHODS: A total of 40 New Zealand White (NZW) rabbits underwent thoracotomy followed by exposure with CO2 laser (n = 10 continuous vs. n = 10 pulsed at 250 Hz with duty cycle 0.15 ms) or ND:YAG laser (n = 10 continuous vs. n = 10 pulsed at 10 Hz with duty cycle 0.10 sec) to the visceral pleural surface using 1 minute of laser exposure (5 watts, defocused to 70 W/cm2 power density) to the exposed lung surface. Rabbits were sacrificed at 4 and 21 days post-injury, and lungs were examined histologically. RESULTS: CO2 and Nd:YAG laser treatment resulted in substantial pulmonary parenchymal injury. While CO2 laser-induced damage was distinct from Nd:YAG histologically, pulsed-mode laser exposures did not reduce lung injury for either laser. Acute edema occurred to depths of 1180 +/- 338 microns for continuous-mode CO2 laser exposures compared to 1,340 +/- 430 microns in pulsed mode (p = .77). For Nd:YAG laser exposure, acute edema depth was 750 +/- 748 microns continuous versus 1120 +/- 367 microns pulsed mode (p = .65). Chronic lung fibrosis depth was 450 +/- 164 microns for CO2 continuous mode compared to 575 +/- 170 microns in pulsed mode (p = .61). Lung fibrosis depth for Nd:YAG was 550 +/- 96 microns, continuous versus 484 +/- 180 microns pulsed mode (p = .76). CONCLUSION: The similarity in injury between pulsed- and continuous-mode exposures suggests that thermal relaxation times are long relative to the selected pulse frequencies in intact living rabbit lungs. Alternatively, brief high-energy pulsations may increase focal temperatures with a tendency to increase injury depth relative to the penetration of the laser light. Thus, pulsed laser modes in these settings appear to be ineffective in reducing laser-induced lung injury in clinical settings.

Animals↗

Optimal pulse durations for the treatment of leg telangiectasias with a neodymium YAG laser.

BACKGROUND: Leg veins can be effectively treated with lasers. However, the optimal pulse duration for small leg veins has not been established in human studies with a Nd:YAG laser. OBJECTIVES: The purpose of this study was to investigate a range of pulse durations to determine an optimal pulse duration for clearance of leg veins. STUDY DESIGN/MATERIALS AND METHODS: After mapping and photo documentation of the leg veins to be treated, a variable pulse duration Neodymium:Yttrium Aluminum Garnet (Nd:YAG) laser (3-100 milliseconds) was used in a single test site session. Pulse durations of 3, 20, 40, 60, 80, and 100 milliseconds were used. At the 3-week follow-up, the optimal pulse duration was defined as that pulse duration which resulted in the most complete clearance of vessels with the least side effects. Up to 20 vessels were then treated using the established "optimal" pulse duration. Final evaluation was at 16 weeks after the initial visit. Three blinded observers rated the percent of vessels completely cleared based on initial and final photographs. RESULTS: Eighteen patients completed the study. Fluence thresholds for immediate vessel changes varied depending on spot size and vessel diameter, with larger fluences required for smaller spot sizes and smaller vessels. Shorter pulse durations (< or =20 milliseconds) were associated with occasional spot sized purpura and spot sized post-inflammatory hyperpigmentation. Longer pulse durations (40-60 milliseconds) achieved superior vessel elimination with less post-inflammatory hyperpigmentation. With a single laser treatment, 71% of the treated vessels cleared. CONCLUSIONS: Compared to shorter pulses (<20 milliseconds), longer pulses may provide gentler heating of the vessel and a greater ratio of contraction to thrombosis.

Adult↗

A newly modified 595-nm pulsed dye laser with compression handpiece for the treatment of photodamaged skin.

BACKGROUND AND OBJECTIVES: The pulsed dye laser set the standard of care for the treatment of vascular lesions, and recent modifications have enabled improved efficacy with fewer side effects. An investigational high energy, variable pulse duration pulsed dye laser has been modified to treat both vascular and pigmented lesions associated with photoaging. Each laser pulse is comprised of a sequence of eight uniform micropulses, which evenly distribute the pulse energy, effectively increasing the purpura threshold at any given fluence. Pigmented lesions are treated with a compression handpiece (CHP) that removes competing vascular target from the field, and helps to prevent purpura. This pilot study was undertaken to determine the optimum laser settings, and to investigate the ability of this device to improve vascular and pigmented lesions associated with photoaging. STUDY DESIGN/MATERIALS AND METHODS: Twenty-four patients with photoaged skin and phototype I-III were enrolled in the study. Thirteen received treatment for vascular and pigmented lesions, and 11 subjects were treated for pigmented lesions alone. Subjects received one to three treatments at 3-4 weeks intervals, and underwent 3- and 12-week follow-up evaluation. The degree of improvement was assessed by subject evaluation as well as comparison of standardized digital photographs by three independent dermatologists. Background erythema was treated with a 12-mm spot size, at a fluence of 7 J/cm(2), and a pulse width of 10 ms. The cryogen cooling was set at 30 mseconds with a 30 ms delay. Individual telangiectasias were treated with a 5- or 7-mm spot size at fluences of 9-14 J/cm(2) and pulse widths of 6-20 mseconds. Pigmented lesions were treated using a 5- or 7-mm spot size, with energy of 9-15 J/cm(2) and a pulse width of 1.5-10 ms without cooling. The CHP had a 7-mm spot size, and fluences of 9-16 J/cm(2), and pulse widths of 1.5 or 3 ms were used in the treatment of pigmented lesions. RESULTS: The treatment was well tolerated without the use of topical anesthetic. All subjects noted improvement in the both vascular and pigmented lesions, and were satisfied with their outcomes. Objectively, there was moderate improvement in background erythema, telangiectasia, and pigmented lesions. Three subjects who were treated with sun tans developed transient hypopigmentation and two subjects developed a transient textural change following pulse stacking for the treatment of pigmented lesions with the conventional handpiece. Purpura was noted in all patients treated for pigment with the conventional handpiece at pulsewidths less than 6 mseconds, as compared to only one that was treated with the CHP. Three patients treated in rapid succession for vascular, and then pigmented lesions with the CHP exhibited purpura, which was prevented in future treatments with 1-2 minutes of topical ice cooling between passes. CONCLUSIONS: This novel 595-nm pulsed dye laser, with a modified pulse sequence and CHP, now has the versatility to safely treat both pigment and vascular changes associated with photoaging.

Adult↗

Neurotransmitter release and its facilitation in crayfish. VIII. Modulation of release by hyperpolarizing pulses.

Quantal postsynaptic currents were recorded by a macro-patch-clamp electrode from synaptic spots on the opener muscle of the walking leg of large crayfish at 0 degrees to 4 degrees C. Through the same electrode, current pulses were applied which de- or hyperpolarized the nerve terminal. The depolarizing test pulse of fixed amplitude and duration elicited EPSCs with an average quantum content m1. If the test pulse was preceded or followed immediately by a modulatory hyperpolarizing pulse, the quantum content m1p of the EPSC was reduced by factors m1/m1p up to 10. This modulation of release increased with amplitude and duration of hyperpolarization, reaching a saturation level for durations greater than 3 ms. If an interval was interposed between modulatory hyperpolarization and test pulse, the reduction of release decayed with increasing interval with a time constant of about 2 ms. The release m2 due to a second test pulse following the first one with 10 ms interval was facilitated, m2/m1 greater than 1. If release by the first test pulse was modulated by associated hyperpolarizing pre- or post-pulses, facilitation of the second test EPSC was not reduced in comparison to facilitation without modulation. The time course of phasic release (distribution of delays of quanta after test pulse) was not appreciably affected by hyperpolarizing pre-pulses, but such post-pulses shortened the delay of the maximum of release. The effects of modulatory pre- and post-pulses could be described by an extension of the model given in H. Parnas et al. (1986). Release 'sites', S, are assumed to have two inactive states, T1 and T.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Does the effect of herbicide pulse exposure on aquatic plants depend on Kow or mode of action?

The highest concentrations of herbicides measured in flowing surface waters are often only present for short periods of time. These herbicide pulses can reach concentrations that would affect aquatic plants if present over a long time. The aim of this study was to assess the effect of a 3-h herbicide pulse relative to the effects of long-term (4 and 7 days) exposure of six herbicides with different sites of action and different K(ow) on the growth of the floating macrophyte Lemna minor. The herbicides were the two photosynthetic inhibitors: diquat and terbuthylazine, the inhibitors of acetolactate syntase (ALS), imazamox and metsulfuron-methyl and the microtubule assembly inhibitors propyzamide and pendimethalin. The log K(ow) ranged from -4.6 to 5.2. For imazamox, metsulfuron-methyl, propyzamide and pendimethalin a 3-h pulse induced the effect on area-specific growth as did a 4-day exposure at an approximate 10-fold higher concentration. For diquat and terbuthylazine a concentration closer to a factor of 100 or more was needed for a 3-h pulse to induce an effect similar to that of a 4-day exposure. For diquat, the low pulse-effect was most likely due to a slow uptake of the hydrophilic ion (log K(ow) = -4.6), as no effect was observed on chlorophyll fluorescence within 8 h after exposure. The chlorophyll fluorescence parameters are expected to respond quickly to a PSI inhibitor as diquat. For terbuthylazine, fluorescence measurements showed an effect on photosynthesis within 1h of exposure, and reached a minimum after 3 h. Recovery was fast, and initial fluorescence was restored within 24 h. Hence, the small pulse effect on area-specific growth was due to rapid recovery of photosynthesis. In contrast to terbuthylazine, the stop in area-specific growth observed for the ALS-and microtubule assembly inhibitors, took up to 4 days to recover from. Such a long recovery time after a pulse of only 3 h indicate that at realistic pulse exposures of up to a day or two, pulse-effects will approach the effects obtained in long-term studies. When investigating the effects of pulse exposures on aquatic plants, we should therefore focus more on non-photosynthetic inhibitors, which might not appear in pulses in as large concentrations as the PSII inhibitors investigated up till now, but whose effect, even in a shorter pulse, can be more damaging.

Aniline Compounds↗

The role of GABAergic inhibition in shaping the response size and duration selectivity of bat inferior collicular neurons to sound pulses in rapid sequences.

Natural sounds, such as vocal communication sounds of many animal species typically occur as sequential sound pulses. Therefore, the response size of auditory neurons to a sound pulse would be inevitably affected when the sound pulse is preceded and succeeded by another sound pulse (i.e., forward and backward masking). The present study presents data to show that increasing strength of GABAergic inhibition relative to excitation contributes to decreasing response size and sharpening of duration selectivity of bat inferior collicular (IC) neurons to sound pulses in rapid sequences. The response size in number of impulses and duration selectivity of IC neurons were studied with a pulse train containing 9 sound pulses. A family of duration tuning curves was plotted for IC neurons using the number of impulses discharged to each presented sound pulse against pulse duration. Our data show that the response size of IC neurons progressively decreased and duration selectivity increased when determined with sequentially presented sound pulses. This variation in the response size and duration selectivity of IC neurons with sequentially presented sound pulses was abolished or reduced during bicuculline and GABA application. Bicuculline application increased the response size and broadened the duration tuning curve of IC neurons while GABA application produced opposite results. Possible mechanisms underlying increasing strength of GABAergic inhibition with sequentially presented sound pulses are presented. Biological significance of these findings in relation to acoustic signal processing is also discussed.

Acoustic Stimulation↗

The effects of intense submicrosecond electrical pulses on cells.

A simple electrical model for living cells predicts an increasing probability for electric field interactions with intracellular substructures of both prokaryotic and eukaryotic cells when the electric pulse duration is reduced into the sub-microsecond range. The validity of this hypothesis was verified experimentally by applying electrical pulses (durations 100 micros-60 ns, electric field intensities 3-150 kV/cm) to Jurkat cells suspended in physiologic buffer containing propidium iodide. Effects on Jurkat cells were assessed by means of temporally resolved fluorescence and light microscopy. For the longest applied pulses, immediate uptake of propidium iodide occurred consistent with electroporation as the cause of increased surface membrane permeability. For nanosecond pulses, more delayed propidium iodide uptake occurred with significantly later uptake of propidium iodide occurring after 60 ns pulses compared to 300 ns pulses. Cellular swelling occurred rapidly following 300 ns pulses, but was minimal following 60 ns pulses. These data indicate that submicrosecond pulses achieve temporally distinct effects on living cells compared to microsecond pulses. The longer pulses result in rapid permeability changes in the surface membrane that are relatively homogeneous across the cell population, consistent with electroporation, while shorter pulses cause surface membrane permeability changes that are temporally delayed and heterogeneous in their magnitude.

Cell Membrane↗

The pulse oximetry gap in carbon monoxide intoxication.

STUDY OBJECTIVE: Pulse oximetry has been reported to be falsely elevated in the presence of carbon monoxide (CO). However, the degree to which pulse oximetry overestimates measured oxyhemoglobin saturation (O2Hb) has not been investigated in patients with CO exposure. This study quantifies the effect of CO on pulse oximetry and O2Hb in a series of patients with elevated carboxyhemoglobin (COHb) levels. METHODS: A prospective case series of 25 pulse oximetry measurements, with concurrent arterial blood gas sampling, were obtained on 16 adults with CO exposure. RESULTS: COHb levels (mean, 16.1%; SD, 11.6%; range, 2.2% to 44%) did not significantly correlate with pulse oximetry saturation (mean, 97.7%; SD, 1.5%; range 96% to 100%) (r = .45; P = .1 [NS]). Compared with COHb, a pulse oximetry gap (mean, 17.5%; SD, 1.5%; range, 2.3% to 42%), defined as pulse oximetry saturation minus O2Hb, yielded a linear regression model: pulse oximetry gap = 1.82 + 0.94 x COHb (SEM = 0.07; F = 204; R2 = .90; P < .0001). CONCLUSION: Oxygen saturation as measured by pulse oximetry failed to decrease to less than 96% despite COHb levels as high as 44%. Regression between the pulse oximetry gap and COHb suggests that pulse oximetry overestimates O2Hb by the amount of COHb present. Pulse oximetry is unreliable in estimating O2Hb saturation in CO-exposed patients and should be interpreted with caution when used to estimate oxygen saturation in smokers.

Adult↗

Advanced pulse oximeter signal processing technology compared to simple averaging. II. Effect on frequency of alarms in the postanesthesia care unit.

STUDY OBJECTIVE: To determine the effect of a new pulse oximeter (Nellcor Symphony N-3000, Pleasanton, CA) with signal processing technique (Oxismart) on the incidence of false alarms in the postanesthesia care unit (PACU). DESIGN: Prospective study. SETTING: Nonuniversity hospital. PATIENTS: 603 consecutive ASA physical status I, II, and III patients recovering from general or regional anesthesia in the PACU. INTERVENTIONS: We compared the number of alarms produced by a recently developed "third"-generation pulse oximeter (Nellcor Symphony N-3000) with Oxismart signal processing technique and a conventional pulse oximeter (Criticare 504, Waukesha, WI). Patients were randomly assigned to either a Nellcor pulse oximeter or a Criticare with the signal averaging time set at either 12 or 21 seconds. For each patient the number of false (artifact) alarms was counted. MEASUREMENTS AND MAIN RESULTS: The Nellcor generated one false alarm in 199 patients and 36 (in 31 patients) "loss of pulse" alarms. The conventional pulse oximeter with the averaging time set at 12 seconds generated a total of 32 false alarms in 17 of 197 patients [compared with the Nellcor, relative risk (RR) 0.06, confidence interval (CI) 0.01 to 0.25] and a total of 172 "loss of pulse" alarms in 79 patients (RR 0.39, CI 0.28 to 0.55). The conventional pulse oximeter with the averaging time set at 21 seconds generated 12 false alarms in 11 of 207 patients (compared with the Nellcor, RR 0.09, CI 0.02 to 0.48) and a total of 204 "loss of pulse" alarms in 81 patients (RR 0.40, CI 0.28 to 0.56). The lower incidence of false alarms of the conventional pulse oximeter with the longest averaging time compared with the shorter averaging time did not reach statistical significance (false alarms RR 0.62, CI 0.3 to 1.27; "loss of pulse" alarms RR 0.98, CI 0.77 to 1.3). CONCLUSIONS: To date, this is the first report of a pulse oximeter that produced almost no false alarms in the PACU.

Anesthesia Recovery Period↗

Sub-microsecond, intense pulsed electric field applications to cells show specificity of effects.

Application of sub-microsecond duration (60-300 ns), intense (15-60 kV/cm) pulsed electric fields (sm/i-PEF) to six types of human cells was examined for its effects on individual cell surface membrane permeability and membrane potential. With short (60 ns) pulses, increasing percentages of Jurkat cells showed propidium iodide (PI) uptake at progressively shorter post-pulse times as the pulse train increased from 1 to 10 sequential pulses, while human blood polymorphonuclear leukocytes (PMN) were unresponsive to these short pulses regardless of train size. With 300 ns pulses, a similar pattern (increasing percentages of cells taking up PI, and progressively shorter times of onset after pulse applications as pulse train size increased) was seen with both Jurkat cells and PMN, but the patterns for both effects were different. Jurkat cell size did not appear to influence the responsiveness of this cell type. Comparisons of sm/i-PEF-induced PI uptake by human monocyte-derived macrophages vs. aged human mononuclear cells, human trunk skin (HTS) cells vs. fresh human mononuclear cells and human macrophages vs. HTS cells showed similar overall effects, but with differences between the patterns for each cell type compared (except the macrophages vs. HTS cells comparison). Application of sm/i-PEFs also caused different patterns of membrane potential loss in Jurkat cells vs. PMN. Jurkat cells developed significant decreases in t heir membrane potential only following the highest intensity pulse applications examined, i.e., 300 ns, 60 kV/cm x5, while PMN showed this effect over the entire range of pulse intensities (300 ns, 15-60 kV/cm, x5) applied. These data indicate that sm/i-PEF applications can have "specificity" (i.e., achieve different levels of effect in different cell types), that cell size does not appear to be the major factor determining sm/i-PEF effects in either Jurkat cells or PMN, that heterogeneous sm/i-PEF effects on cells tend to become homogeneous with increasing pulse train size, and that specificity of sm/i-PEF applications effects can occur at either end of the sm/i-PEF intensity spectrum examined.

Age Factors↗

Pulsed flow modulation for high-speed GC using a pressure-tunable column ensemble.

A computer-driven pressure controller is used to deliver pressure pulses to the junction point of two series-coupled columns using different stationary-phase chemistries. The column ensemble consists of a trifluoropropylmethyl polysiloxane column followed by a dimethyl polysiloxane column. Each pressure pulse causes a differential change in the carrier gas velocities in the two columns, which lasts for the duration of the pulse. A pressure pulse is used to selectively increase the separation of a component pair that is separated by the first column but coelutes from the series-coupled ensemble. If both components are on the same column when the pulse is applied, a small change in the ensemble separation occurs. If one component of the pair is on the first column and the other component is on the second column, a pressure pulse can result in a much larger change in the ensemble separation for the component pair. A model with a spreadsheet algorithm is used to predict the effects of a pressure pulse on the trajectories of component bands on the column ensemble. The effect of the initiation time of a pressure pulse is investigated for a two-component mixture that coelutes from the column ensemble. For the case where the entire pressure pulse occurs when one of the components is on the first column and the other component is on the second column, the peak separation from the ensemble increases nearly linearly with the product of the pressure pulse amplitude and the pulse duration. Peak shape artifacts are observed if the pressure pulse occurs when a solute band is migrating across the column junction point.

Journal Article↗

Generation of bcr-abl specific cytotoxic T-lymphocytes by using dendritic cells pulsed with bcr-abl (b3a2) peptide: its applicability for donor leukocyte transfusions in marrow grafted CML patients.

Dendritic cells (DC), the most potent 'professional' antigen-presenting cells, hold promise for improving the immunotherapy of cancer. In this study, we investigated the ability of normal donor DC pulsed ex vivo with 12 mer bcr-abl (b3a2) peptide to generate b3a2-specific autologous or HLA-identical sibling donor's cytotoxic T-lymphocytes (CTL). DC that were grown from normal peripheral blood adherent cells or purified DC precursors in the presence of GM-CSF and IL-4, were pulsed with b3a2-peptide then were induced to become mature and functional cells by the addition of TNF-alpha. These peptide-pulsed mature DC elicited a potent b3a2-specific CTL response in vitro. The b3a2-peptide pulsed DC-primed peripheral blood lymphocytes (PBL) displayed significantly higher cytotoxic activity compared with peptide non-pulsed DC-primed PBL against target cells, which are b3a2 positive marrow cells derived from HLA-identical sibling chronic myelogenous leukemia (CML) patient, or peptide-pulsed autologous macrophages (P < 0.001). In addition, the b3a2 peptide-pulsed DC-primed and non-pulsed DC-primed PBL showed no cytotoxic response against peptide non-pulsed autologous macrophages. These findings revealed that normal donor PBL pre-immunized with b3a2-peptide pulsed autologous DC could increase the graft-versus-leukemia effect without exaggerating graft-versus-host-disease. Both CD8+ and CD4+ T lymphocytes were shown to be involved in the effector cell populations. The b3a2 peptide-pulsed DC-primed T cells were significantly superior in their production of GM-CSF and TNF-alpha compared with peptide non-pulsed DC-primed T cells. These intriguing preclinical results imply the feasibility of developing b3a2 peptide-DC based protocol for in vitro sensitization of normal donor leukocytes before donor leukocyte transfusions for patients with CML, who relapsed after HLA-matched sibling bone marrow transplantation.

Blood Donors↗

Laser therapy of spider leg veins: clinical evaluation of a new long pulsed alexandrite laser.

BACKGROUND: The response of spider leg veins to laser or intense pulsed light therapy has generally been characterized by varying degrees of success and frequently inconsistent clinical response rates. OBJECTIVE: The purpose of this study was to examine the effectiveness of the 755 nm long pulsed infrared alexandrite (LPA) laser for the treatment of leg telangiectasias. METHODS: This study was constructed in four phases. Phase I examined 28 patients with variable sized telangiectasias using 5 treatment parameters (15 J/cm2 x 1 pulse, 20 J/cm2 x 1 pulse, 20 J/cm2 x 2 pulses, 20 J/cm2 x 3 pulses, or 30 J/cm2 x 1 pulse). Each patient received 3 treatments at 4 week intervals with the LPA. Patient diaries were obtained to examine the effects of the treatments. Subjective grading was performed at each follow-up visit by the investigators. Blinded objective grading was performed at the conclusion of the study by trained observers. Phase II examined the effects of these treatment parameters on varying vessel diameters. Vessels were grouped into small (<0.4 mm), intermediate (0.4-1.0 mm), and large (1.0-3.0 mm) subsets. Phase III examined the effects of a combination of LPA treatment followed by 23.4% hypertonic saline sclerotherapy. Subjective and blinded objective grading was used to determine improvement after a single treatment with the LPA at 20 J/cm2, single pulsed with a pulse duration of 5 or 10 msec followed by treatment with 23.4% hypertonic saline injected 3, 7, 14, or 28 days after laser therapy. Phase IV involved biopsies after LPA treatment alone at time intervals of immediately posttreatment and 5 and 21 days posttreatment. RESULTS: These evaluations revealed that the optimal treatment parameters for LPA therapy alone appeared to be 20 J/cm2, double pulsed at a repetition rate of one Hz. After 3 treatments at 4 week intervals, subjective grading indicated a 63% reduction in leg telangiectasias. Medium diameter vessels responded best with small vessel diameters responding poorly, if at all. The addition of 23.4% hypertonic saline sclerotherapy performed 3 to 7 days after laser therapy (LPA at 20 J/cm2, single pulsed with a pulse duration of 5 msec) produced 87% reduction in leg telangiectasias. Biopsies after LPA treatment revealed vessel wall endothelial cell necrosis at 5 days with fibrosis occurring at 3 weeks. The optimal clinical "window" for sclerotherapy seems to coincide with the period of endothelial cell necrosis. CONCLUSION: LPA therapy is most effective for leg telangiectasias 0.4-3.0 mm in diameter. This LPA technique is significantly improved with the addition of sclerotherapy.

Adult↗

Histologic effect of a variable pulsed Er:YAG laser.

BACKGROUND: Carbon dioxide (CO2) lasers used for laser resurfacing produce significant thermal damage. Short-pulsed Er:YAG lasers provide significant control over depth of ablation with minimal thermal damage. Newer combined short-pulsed/long-pulsed Er:YAG lasers offer the potential for both precise control over depth of ablation and degree of chosen thermal damage. OBJECTIVE: To determine the correlation between the histologic effects of an ablative short-pulsed Er:YAG laser and/or a thermally damaging longer-pulsed Er:YAG laser and the findings chosen on the touch panel of such a machine. METHODS: In situ lasing of abdominoplasty specimens was undertaken. Various depths of ablation and/or thermal effect were chosen on the machine. The tissue was laser irradiated, histologically analyzed, and ablation/thermal depths of damage were analyzed by a blinded dermatopathologist. RESULTS: Postlaser histologic depths of ablation after short-pulsed Er:YAG laser resurfacing correlated well with those chosen on the machine. However, when a longer, thermally damaging Er:YAG laser pulse was chosen, chosen ablative and/or thermal depths of damage showed histologic correlation only for the first pass. With repeated passes, using the variable pulse width, the histologic depth of ablation and residual thermal damage do not match the settings on the machine. CONCLUSION: A dual-mode Er:YAG laser provides the histologic control over depth of ablation seen with all short-pulsed Er:YAG lasers. In addition, the histologic thermal effect desired from CO2 lasers could be observed when such a system is used with longer Er:YAG laser pulses. Good correlation between chosen laser parameters and histologic findings are seen with all chosen levels of short-pulsed Er:YAG laser parameters. Good correlation is seen between the chosen laser parameters and histologic findings after a first pass of either a longer pulsed thermal damaging Er:YAG laser alone or in combination with a shorter pulsed ablative Er:YAG laser. However, subsequent laser passes in these modes showed poor correlation between the chosen laser parameters and histologic effect. Such findings have important implications when such a laser is used clinically.

Dermatologic Surgical Procedures↗

Postoperative monitoring of pediatric toe-to-hand transfers with differential pulse oximetry.

Twenty-three toe-to-hand transfers performed in 21 children were monitored after surgery using differential pulse oximetry for 4 to 12 days. Pulse rate recorded by the pulse oximetry monitored the patency of the arterial anastomosis, whereas oxygen saturation (SaO(2)) corresponded to the patency of the venous anastomosis; these were both compared with the systemic pulse rate and oxygen saturation recorded by a second control pulse oximeter probe attached to a contralateral finger or toe. All 23 toe transfers were ultimately successful, but 2 required re-exploration for anastomotic problems detected by the pulse oximeter. Based on this experience, the following criteria have been developed for the nursing and junior medical staff: if the arterial pulse of the toe transfer is lost completely or if the pulse rate differs significantly from the systemic pulse rate, measured by the second control pulse oximeter, thrombosis of the arterial anastomosis should be suspected. If the oxygen saturation of the toe transfer decreases below the oxygen saturation measured by the control pulse oximeter and this differential is sustained over a period of time, thrombosis of the venous anastomosis should be suspected. Differential pulse oximetry appears to be superior to temperature monitoring and percutaneous and laser Doppler monitoring and provides the most simple and continuous technique of noninvasive postoperative monitoring of toe-to-hand transfers in children requiring reconstruction of traumatic or congenital deformities.

Adolescent↗

Clinical use of new-generation pulse oximeters in the neonatal intensive care unit.

Continuous monitoring by pulse oximetry is a common practice for preterm and critically ill newborns. A new generation of motion-tolerant pulse oximeters have been designed for improved clinical performance with a substantial reduction in alarm frequency. However, little is known about the differences among these new-generation pulse oximeters in the neonatal intensive care unit (NICU). The purpose of this study is to assess the clinical performance of two new-generation pulse oximeters in the NICU. Two new-generation pulse oximeters were used simultaneously to monitor 36 patients in the NICU. The two devices studied were the Philips FAST and the Masimo SET. Patients were randomly assigned for their digit selection and data were collected only when waveforms were of good quality and/or the pulse oximeter's pulse rate (PR) correlated with the electrocardiogram heart rate (HR). The data for oxygen saturation measurements, number of true and false alarms, and number of dropouts as well as the duration of dropouts for each pulse oximeter were recorded by the primary investigator at 5-minute intervals for a period of 2 hours on each patient. Dropouts are instances when the pulse oximeter alarm sounds due to its inability to identify the arterial pulse and provide an oxygen saturation reading. The mean gestational age for the study group was 32 weeks (rang, 24 to 42 weeks). Repeated-measures analysis of variance indicated no difference between the two devices across all time measurements (p=0.357). In addition, paired t-tests for true alarms and false alarms were not significant, with p-values of 0.151 and 0.869, respectively. There was a difference in the number of data dropouts (p<0.001): the Philips device had a nearly six-fold increase in the number of dropouts (Philips 247 versus Masimo 38). The duration of dropouts was also significant; the Philips device had three times longer duration of dropouts. Physiologic monitoring in the critical care setting requires accurate data measurements. The two new-generation pulse oximeters, the Philips FAST and Masimo SET, are equally sensitive in their ability to identify true and false alarms. Masimo pulse oximeter with its signal extraction technology, however, provides more consistent and accurate reporting of SpO2 values as demonstrated by its markedly decreased incidence of data dropouts. The Masimo unit appears to be more resistant to the effects of motion artifact.

Humans↗

A cell number-counting factor regulates group size in Dictyostelium by differentially modulating cAMP-induced cAMP and cGMP pulse sizes.

A secreted counting factor (CF), regulates the size of Dictyostelium discoideum fruiting bodies in part by regulating cell-cell adhesion. Aggregation and the expression of adhesion molecules are mediated by relayed pulses of cAMP. Cells also respond to cAMP with a short cGMP pulse. We find that CF slowly down-regulates the cAMP-induced cGMP pulse by inhibiting guanylyl cyclase activity. A 1-min exposure of cells to purified CF increases the cAMP-induced cAMP pulse. CF does not affect the cAMP receptor or its interaction with its associated G proteins or the translocation of the cytosolic regulator of adenylyl cyclase to the membrane in response to cAMP. Pulsing streaming wild-type cells with a high concentration of cAMP results in the formation of small groups, whereas reducing cAMP pulse size with exogenous cAMP phosphodiesterase during stream formation causes cells to form large groups. Altering the extracellular cAMP pulse size does not phenocopy the effects of CF on the cAMP-induced cGMP pulse size or cell-cell adhesion, indicating that CF does not regulate cGMP pulses and adhesion via CF's effects on cAMP pulses. The results suggest that regulating cell-cell adhesion, the cGMP pulse size, or the cAMP pulse size can control group size and that CF regulates all three of these independently.

3',5'-Cyclic-AMP Phosphodiesterases↗

Overview of the market and consumption of pulses in Europe.

The human consumption of grain legumes and pulses in Europe and the EU is lower than in other regions of the world. However, there is a lot of variation between countries and an overall slight increase has been observed in recent years. The major trends in the EU pulse market are illustrated here with a specific focus on Spain, France and the UK, which account for about 60 % of the EU pulse consumption. The ways in which pulses are consumed are very different in the various EU countries, due to different regional food habits and traditions, and to differences in the supplies of grain legumes and the markets. Canned products dominate pulse sales compared with dry pulses sold in packets. Dry beans are the most consumed of the pulses in the EU, but the preference between species varies according to country. The factors limiting the consumption of pulses in the EU are mainly: an inadequate level of innovation for developing products adapted to modern life, a small home supply of pulses and competition from cheaper low-quality imports. Recently, however, consumers are favouring healthy and balanced vegetable diets. Pulses have significant nutritional and health advantages for consumers and their cultivation has a positive impact on agriculture and the environment. Therefore the trend in the consumption of pulses could change, especially if publicity about the benefits of pulses is improved and if the food industry and professional organizations take up the challenge to incorporate grain legumes in novel, convenient and healthy food products.

Culture↗