Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Multicolor”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

Synthesis, photophysical and electrochemical properties, and biological labeling studies of cyclometalated iridium(III) bis(pyridylbenzaldehyde) complexes: novel luminescent cross-linkers for biomolecules.

We report the synthesis, characterization, photophysical, and electrochemical properties of a series of luminescent cyclometalated iridium(III) complexes containing two aldehyde functional groups [Ir(pba)(2)(N-N)](PF(6)) (Hpba=4-(2-pyridyl)benzaldehyde; N-N=2,2'-bipyridine, bpy (1), 1,10-phenanthroline, phen (2), 3,4,7,8-tetramethyl-1,10-phenanthroline, 3,4,7,8-Me(4)-phen (3), 4,7-diphenyl-1,10-phenanthroline, 4,7-Ph(2)-phen (4)). The X-ray crystal structure of complex 1 has been investigated. Upon photoexcitation, complexes 1-4 exhibit intense and long-lived emission in fluid solutions at 298 K and in low-temperature glass. The luminescence is assigned to a triplet intra-ligand ((3)IL) excited state associated with the pba(-) ligand, probably with mixing of some triplet metal-to-ligand charge-transfer ((3)MLCT) (dpi(Ir)-->pi*(pba(-))) character. Since each of these complexes possesses two aldehyde groups, which can react with the primary amine groups of biomolecules to form stable secondary amines after reductive amination, we have investigated the possibility of these complexes as novel luminescent cross-linkers for biological substrates. L-Alanine has been labeled with complexes 1-4 to give the luminescent bioconjugates 1-(Ala)(2)-4-(Ala)(2). These conjugates show strong photoluminescence with long emission lifetimes under ambient conditions. On the basis of the emission energy trend, the excited state of these luminescent bioconjugates is likely to bear a high parentage of (3)MLCT (dpi(Ir)-->pi*(N-N)) character. In addition, the glycoprotein avidin (Av) has also been conjugated with complexes 1-4 to give the bioconjugates 1-Av-4-Av. Upon photoexcitation, these bioconjugates also display intense and long-lived (3)MLCT (dpi(Ir)-->pi*(N-N)) emission in aqueous buffer at 298 K. Furthermore, a heterogeneous competitive assay for biotin has been developed using 2-Av and biotinylated microspheres. We have shown that complexes 1-4 represent a new class of multicolor luminescent cross-linkers for biomolecular species.

Avidin↗

Selection of lymphocyte gating protocol has an impact on the level of reliability of T-cell subsets in aging specimens.

BACKGROUND: In the past decade, human immunodeficiency virus (HIV) lymphocyte immunophenotyping has evolved significantly. New fluorochromes, new multicolor reagents, enhanced instruments, and the capacity to provide absolute cell counts using the single-platform technique have all contributed to the reliability of T-cell subset measurements. In this study, four gating protocols were evaluated to select the most robust method for T-cell subset enumeration. METHODS: Peripheral blood specimens from 21 HIV(+) and 20 HIV(-) individuals were monitored up to 96 h. Aliquots of specimens were stored at room temperature and analyzed at 6 (baseline), 48, 72, and 96 h. Aliquots were stained with CD45-fluorescein isothiocyanate (FITC)/CD3PC5/CD4RD1/CD8ECD. Data analysis was performed with all four gating protocols. RESULTS: Only with fresh blood did all protocols provide similar results. From samples that were 48 h old, the choice of gating strategy had a dramatic impact on immunophenotyping results. The largest deviations from baseline values occurred at 96 h and gating protocols that included dual light scatter gates provided the greatest shift of T-cell subset values over time. The gating protocols that were based exclusively on cell lineage-specific gates gave the most robust T-cell values up to 96 h. CONCLUSION: By selecting the appropriate gating protocol, the temporal integrity of specimens can be extended up to 4 days.

Acquired Immunodeficiency Syndrome↗

Cyanine dye labeling reagents for sulfhydryl groups.

Cyanine and merocyanine dyes are introduced as new fluorescent reagents for covalently labeling proteins and other biomolecules. These dyes, which contain iodoacetamide functional groups, have high extinction coefficients and moderate quantum yields. A major advantage of these polymethine dyes is the easy manipulation of their spectral properties during synthesis. Cyanines containing reactive functional groups can be made with absorption maxima ranging from less than 500 nm to greater than 750 nm. This property opens additional regions of the spectrum for experiments involving the simultaneous multicolor analysis of different fluorescent probes. The cyanines, which are relatively insensitive to solvent property changes, are complemented by the merocyanines, which are keen indicators of solvent polarity.

Carbocyanines↗

Cyanine dye labeling reagents containing isothiocyanate groups.

New isothiocyanate derivatives of cyanine dyes were synthesized as fluorescent covalent labeling reagents for proteins and other biomolecules. These dyes have maximum absorbance in the red and near infrared regions of the spectrum, have high extinction coefficients and have adequate quantum yields. Incorporating two alkyl sulfonate groups in the dye structures increases their water solubility, which is beneficial for labeling biological molecules in aqueous solution. Reactivities of proteins with these new cyanines are similar to their reactivities with fluorescein isothiocyanate. These new labeling reagents are complementary to the fluorescein and rhodamine reagents, expanding the possibilities of multicolor analyses. Sheep anti-mouse-IgG antibody was labeled with a pentamethine cyanine dye (CY5.8-ITC) and used with a fluoresceinated antibody as a second reagent for detecting human T-cell subsets by flow cytometry.

Antibodies↗

Flow cytometric detection of the mitochondrial BCL-2 protein in normal and neoplastic human lymphoid cells.

The bcl-2 proto-oncogene, rearranged and deregulated in B-cell lymphomas bearing the t(14;18) translocation, encodes an inner mitochondrial membrane protein that blocks apoptotic cell death. We have developed a sensitive immunofluorescence assay for the single- and multicolor flow cytometric analysis of bcl-2 protein in relation to other markers and cell cycle, based on a fixation-permeation step of cells with paraformaldehyde and Triton X100 and the use of a bcl-2 specific monoclonal antibody (MoAb). As an application of this method, we have examined the expression of bcl-2 in normal and neoplastic lymphoid cells. We have found that greater than 80% of normal T-and B-cells are bcl-2 positive; following in vitro mitogen activation, the bcl-2 reactivity decreased slightly in the former but markedly in latter cells. In both cases the bcl-2 expression was not restricted to a specific phase of the cell cycle, as evidenced by two-color analysis. On lymphoblastoid cell lines, the bcl-2 staining intensity was variable and not necessarily correlated to molecular rearrangements of the bcl-2 gene. Among fresh B-cell non-Hodgkin's lymphomas (B-NHL), most sporadic Burkitt's cases were bcl-2 negative. Of four centroblastic-centrocytic cases with rearrangements of the bcl-2 gene, only two presented elevated amounts of bcl-2 protein, indicating that the levels of bcl-2 are not diagnostic of the translocation.(ABSTRACT TRUNCATED AT 250 WORDS)

Antibodies, Monoclonal↗

Analysis of antifading reagents for fluorescence microscopy.

The utility of p-phenylenediamine, 1,4-di-azobicyclo-(2.2.2.)-octane, and the commercial products Citifluor, Slowfade, and Vectashield, antifading agents frequently used as mounting media for fluorescence in situ hybridization, was investigated. Fading curves for bound fluorochromes were recorded with digital microscopy, and relative fluorescence intensities of fluorochromes in solution were measured with an aperture defined measurement system. The three commonly used fluorochromes, fluorescein, tetramethyl rhodamine, and coumarin, were studied. Vectashield offered the best antifading properties for all three fluorochromes, although their relative fluorescence intensity was slightly less in Vectashield in comparison with other antifading agents. In Vectashield, fluorescein, tetramethyl rhodamine, and coumarin showed half-life times of 96, 330, and 106 s, respectively, whereas in 90% glycerol in PBS (pH 8.5), these half-life time values were 9, 7, and 25 s, respectively. Vectashield is particularly recommended as a mounting medium for quantitative digital imaging microscopy and for multicolor applications, where it is easy to have errors due to differences in fading rates of the fluorochromes.

Coumarins↗

Nucleic acid dyes for detection of apoptosis in live cells.

Apoptotic thymocytes were found to be much dimmer than normal thymocytes when stained with several nucleic acid dyes. These dyes provide a quick and simple assay for apoptosis which works for live cells and does not require a UV laser. The collection of dyes giving this staining pattern includes reagents suitable for use in either the FL1, FL2, or FL3 channel of a standard FACScan. Cells identified by these reagents were identical to apoptotic thymocytes defined by several widely used criteria: (i) rapid uptake of Hoechst 33342 but exclusion of propidium iodide, (ii) merocyanin 540 bright, and (iii) sub-G1 DNA content when permeabilized in a buffer that elutes fragmented DNA. In addition, L3T4/Thy-1 dim thymocytes were included in the dyc dim population. The standard Hoechst 33342 and merocyanin 540 assays were not able to separate the normal and apoptotic populations in HL-60 cells treated with camptothecin. However, the dyes SYTO-16 and LDS-751 both gave adequate differentiation of apoptotic from nonapoptotic cells in this model system. Some of these dyes also emit very little in other fluorescence channels of the flow cytometer and can be used in multicolor assays on cytometers equipped with only a single argon-ion laser.

Acridine Orange↗

Alterations of T-cell receptor variable region expression in human immunodeficiency virus disease.

Since only a small percentage of CD4+ lymphocytes is infected at any one time during the course of human immunodeficiency virus (HIV) disease, a question central to the pathogenesis of HIV is whether or not the depletion of CD4+ lymphocytes is a random or selective event. The majority of peripheral blood T lymphocytes use alpha and beta variable chains as components of their T-cell receptor (TCR) complex. Depletion of CD4+ T lymphocytes from the peripheral blood may be dependent on the V beta chain expressed by the CD4+ cell, based on the hypothesis that HIV may encode a superantigen. Peripheral blood from normal controls and HIV+ patients was studied for alterations in the expression of various V beta chains of the TCR. Three-color flow cytometry was used to determine the expression of V beta 2, V beta 3, V beta 8, V beta 13, and V beta 19 on all lymphocytes and on both CD4+ and CD8+ lymphocytes independently. Alteration of the V beta chains in HIV+ disease was analyzed as a function of absolute CD4 count and Centers for Disease Control (CDC) stage of the patient. These data suggest that the loss of T helper (CD4) lymphocytes during the course of HIV disease may be a selective event. These data are consistent with the hypothesis that selective depletion of CD4+, V beta 19+ lymphocytes may be due to the encoding of a superantigen by HIV. Furthermore, using multicolor flow cytometry and stratifying patients by absolute CD4 counts (or stage of disease) may reveal immunologic changes that might otherwise be overlooked.

Adult↗

Alterations in phenotype and cell-surface antigen expression levels of human monocytes: differential response to in vivo administration of rhM-CSF or rhGM-CSF.

We investigated, via multicolor flow cytometry, the in vivo effects of colony-stimulating factors (CSFs) on cell size, frequencies, and expression of surface antigens on peripheral blood monocytes from melanoma patients treated concurrently with CSFs and tumor-specific monoclonal antibody (mAb) R24. Recombinant human macrophage colony-stimulating factor (rhM-CSF) increased cell size, relative percentages of monocytes, percentages of CD14+, HLA-DQ+, CD11b+, and CD16+ monocytes, and cell-surface expressions of HLA-DR and CD11b; rhM-CSF also up-regulated cell-surface expression of CD14 on CD14brightCD16- monocytes. Recombinant human granulocyte-macrophage colony-stimulating factor (rhGM-CSF) increased cell size, percentages of CD14+, HLA-DQ+, and CD11b+ monocytes, and cell-surface expressions of HLA-DR, HLA-DQ, CD11b, and CD58. Relative percentages of monocytes and CD16+ cells and cell-surface expression of CD14 on CD14brightCD16- monocytes decreased. In addition, monocytes derived from patients treated with rhM-CSF showed functional activity when assayed in vitro for antibody-dependent cellular cytotoxicity (ADCC). During treatment and coincident with increased CD16 expression, monocytes derived from rhM-CSF patients had enhanced levels of cytotoxicity towards melanoma target cells compared to healthy controls and to patients treated with rhGM-CSF.

Antibodies, Monoclonal↗

Effect of anti-CD20 monoclonal antibody, Rituxan, on cynomolgus monkey and human B cells in a whole blood matrix.

BACKGROUND: Cynomolgus monkeys are widely used animal models in biomedical research. The differences between cynomolgus monkey and human B cells are not completely understood. However, these differences are of crucial importance for interpretation of data from studies on new therapeutic agents aimed at B-cell depletion, such as anti-CD20 monoclonal antibodies. METHODS: Multicolor fluorescence-activated cell sorting analysis of peripheral blood B cells was performed on samples treated ex vivo with the anti-CD20 therapeutic monoclonal antibody, Rituxan, in a whole blood matrix. RESULTS: In contrast to humans, cynomolgus monkeys had two distinct B-cell subsets, CD20highCD40lowCD21- and CD20lowCD40highCD21+. These B-cell subsets had a 2.5-fold difference in the EC50 for Rituxan binding and differed significantly in their in vitro susceptibility to Rituxan depletion. Human B cells were similar to the CD20lowCD40highCD21+ cynomolgus monkey B cells with regard to their EC50 for Rituxan and response to Rituxan in a whole blood matrix assay. CD21 was upregulated, whereas CD40 was downregulated at incubation with Rituxan in the CD20lowCD40highCD21+ monkey and human B cells in a concentration-dependent manner. CONCLUSIONS: These findings have direct implications for in vivo studies of therapeutic agents that target B cells in cynomolgus monkeys and for extrapolation of the results to humans. In addition, our data are consistent with the model in which CD20, CD21, and CD40 exist in a supramolecular complex that is affected by anti-CD20 monoclonal antibodies.

Animals↗

Analysis of violet-excited fluorochromes by flow cytometry using a violet laser diode.

BACKGROUND: Low power violet laser diodes (VLDs) have been evaluated as potential replacements for water-cooled argon-ion and krypton-ion ultraviolet and violet lasers for DNA content analysis using the Hoechst dyes and 4,6-diamidino-2-phenylindole (Shapiro HMN, Perlmutter NG: Cytometry 44:133-136, 2001). In this study, we used a VLD to excite a variety of violet-excited fluorescent molecules important in biomedical analysis, including the fluorochromes Cascade Blue and Pacific Blue, the expressible fluorescent protein cyan fluorescent protein (CFP), and the fluorogenic alkaline phosphatase (AP) substrate 2-(5'-chloro-2'-phosphoryloxyphenyl)-6-chloro-4-(3H)-quinazoline (ELF-97; for endogenous AP detection and cell surface labeling with AP-conjugated antibodies). METHODS: Comparisons were made between VLD excitation and a krypton-ion laser emitting at 407 nm (both at higher power levels and with the beam attenuated at levels approximating the VLD) on the same FACSVantage SE stream-in-air flow cytometer. We evaluated a Power Technology 408-nm VLD (30 mW) equipped with circularization optics (18 mW maximum output, set to 15 mW) and a Coherent I-302C krypton-ion laser emitting at power levels ranging from 15 to 75 mW. RESULTS: Cascade Blue, Pacific Blue, and CFP showed comparable signal-to-noise ratios and levels of sensitivity with VLD excitation versus the krypton-ion laser at high and VLD-matched power outputs. Multicolor fluorescent protein analysis with 488-nm excitation of green fluorescent protein and DsRed and VLD excitation of CFP was therefore feasible and was demonstrated. Similar levels of excitation efficiency between krypton-ion and VLD sources also were observed for ELF-97 detection. CONCLUSIONS: These evaluations confirmed that VLDs may be cost- and maintenance-effective replacements for water-cooled gas lasers for applications requiring violet excitation in addition to DNA binding dyes.

Alkaline Phosphatase↗

Intracellular phospho-protein staining techniques for flow cytometry: monitoring single cell signaling events.

BACKGROUND: Recent advances in intracellular staining techniques, cytometer technology, fluorescent reagents, and antibody production have expanded the number of intracellular antigens that can be analyzed by flow cytometry. Measurement of protein phosphorylation with phospho-specific antibodies has given insight into kinase signaling cascades. However, available techniques for phospho-epitope staining can differ greatly, making it necessary to understand the differences between the outcomes when such techniques are applied and to develop robust and reproducible methods of application. METHODS: Ten different cellular fixation and permeabilization techniques were tested for their ability to provide phospho-specific staining. Combinations of formaldehyde, methanol, ethanol, acetone, Triton X-100, and saponin were used as fixation and permeabilization reagents. Phospho-specific antibodies were labeled with Alexa Fluor dyes to provide multicolor analysis of different signaling events simultaneously within individual cells. RESULTS: Fixing cells with 1.5% formaldehyde followed by permeabilization in methanol gave optimal results for pERK, pp38, pJNK, pStat1, pStat5, and pStat6 staining. Alteration of formaldehyde fixation and methanol permeabilization times affected measurements of phosphorylation induction. Phospho-specific flow cytometric analyses correlated well with Western blotting, providing cross platform validation of the technique. CONCLUSIONS: Measuring phosphorylation events by flow cytometry provides a rapid and efficient way to measure kinase cascades in individual cells. Stability of phospho-epitopes in methanol allows long-term storage of samples prior to analysis. Multiple signaling cascades can be monitored simultaneously through the use of different fluorophore labels to determine specificity of ligands or inhibitors. Application of optimized techniques to heterogeneous cell types such as peripheral blood or murine splenocytes may allow signaling to be analyzed simultaneously in immune cell subsets.

Antibodies, Monoclonal↗

Flow cytometer electronics.

Flow cytometers, like all things electronic, have undergone rapid evolution since the introduction of the first commercial instruments 30 years ago. Cytometers then had so little automation and sophistication that the operator had to be expert in many different scientific disciplines to be able to coax any data at all out of the instrument. But trends in electronic components toward higher speed, smaller size, and lower power consumption have allowed the instruments to become faster, more sensitive, and actually quasi-intelligent. Automation of complex processes that once required considerable operator expertise, such as running a high-speed sort or correctly compensating a multicolor experiment, has expanded the number of flow cytometry applications and the number of flow cytometry users; there is no reason to expect that trend to stop. This review discusses the electronic components of a current "generic" flow cytometer from a functional point of view with the hope that a better understanding of what is going on "inside the box" will lead to a better understanding of how operator-selectable instrument settings can influence the quality of the data produced.

Computers↗

Slide-based cytometry and predictive medicine: the 8th Leipziger workshop and the 1st international workshop on slide-based cytometry.

Slide-based cytometry (SBC) and related techniques offer unique tools to perform complex diagnostic procedures at very early disease stages. Multicolor or polychromatic analysis of cells by SBC is of special importance, not only as a cytomics technology platform, but for patients with low blood volume such as neonates. The exact knowledge of the location of each cell on the slide allows the specimen to be restained and subsequently reanalyzed. These separate measurements can be fused to one data file (merging), increasing the information obtained per cell. Relocalization and optical evaluation of the cells, a typical feature of SBC, can be of integral importance for cytometric analysis. Predictive medicine is aimed at the detection of changes in the patient's state prior to the manifestation of deterioration or improvement. Such instances are concerned with multiorgan failure in sepsis or noninfectious posttraumatic shock in intensive care patients, or the pretherapeutic identification of high risk patients in cancer cytostatic therapy. Early anti-infectious or anti-shock therapy, as well as curative chemotherapy in combination with stem cell transplantation, may provide better survival chances for the patient as well as concomitant cost containment. Predictive medicine-guided, individualized, early reduction or cessation of therapy may lower or abrogate potential therapeutic side effects (individualized medicine). With the 8th Leipziger Workshop and the 1st International Workshop on Slide-Based Cytometry, cytomics technologies moved to more practical applications in the clinics and the clinical laboratory. This development will be continued in 2004, at the upcoming Leipziger Workshop and the International Workshop on Slide-Based Cytometry.

Cytodiagnosis↗

Construction and application of a full-coverage, high-resolution, human chromosome 8q genomic microarray for comparative genomic hybridization.

BACKGROUND: Array-based comparative genomic hybridization (aCGH) enables genome-wide quantitative delineation of genomic imbalances. A high-resolution contig array was developed specifically for chromosome 8q because this chromosome arm is frequently altered in many human cancers. METHODS: A minimal tiling path contig of 702 8q-specific bacterial artificial chromosome (BAC) clones was generated with a novel computational tool (BAC Contig Assembler). BAC clones were amplified by degenerative oligonucleotide primer (DOP) polymerase chain reaction and subsequently printed onto glass slides. For validation of the array DNA samples of gastroesophageal and prostate cancer cell lines, and chronic myeloid leukemia specimens were used, which were previously characterized by multicolor fluorescence in situ hybridization and conventional CGH. RESULTS: Single and double copy gains were confidently demonstrated with the 8q array. Single copy loss and high-level amplifications were accurately detected and confirmed by bicolor fluorescence in situ hybridization experiments. The 8q array was further tested with paraffin-embedded prostate cancer specimens. In these archival specimens, the copy number changes were confirmed. In fresh and archival samples, additional alterations were disclosed. In comparison with conventional CGH, the resolution of the detected changes was much improved, which was demonstrated by an amplicon of 0.7 Mb and a deletion of 0.6 Mb, both spanned by only six BAC clones. CONCLUSIONS: A comprehensive array is presented, which provides a high-resolution method for mapping copy number alterations on chromosome 8q.

Adenocarcinoma↗

Regenerative and predictive medicine of cardiovascular disease: the 9th Leipziger Workshop and the 2nd International Workshop on slide based cytometry.

Slide-based cytometry (SBC) and related techniques offer unique tools to perform complex immunophenotyping, thereby enabling diagnostic procedures at very early disease stages. Multicolor or polychromatic analysis of cells by SBC is of special importance, not only as a cytomics technology platform but also for patients with low blood volume such as neonates. The exact knowledge of the location of each cell on the slide allows restaining and subsequent reanalysis of the specimen. These separate measurements of the same specimen can be fused to one data file (merging), thus increasing the information obtained per cell. Relocalization and optical evaluation of the cells, a feature typical of SBC, can be of integral importance for cytometric analysis. Due to this feature, artifacts can be excluded and morphology of measured cells can be documented. Predictive medicine aims at the detection of changes in patient's state before the manifestation of the disease or its complications. Such instances concern multiorgan failure in sepsis or noninfectious posttraumatic shock in intensive care patients or the pretherapeutic identification of high-risk patients undergoing cancer cytostatic therapy. Early anti-infectious or antishock therapy and curative chemotherapy in combination with stem cell transplantation may provide better chances of patients' survival at concomitant cost containment. Predictive medicine that guides early individualized decrease or cessation of therapy may lower or abrogate potential therapeutic side effects (individualized medicine). Regenerative medicine concerns patients who have diseased and injured organs and may be treated with transplanted organs. However, there is a severe shortage of donor organs that is worsening yearly given the aging population. Regenerative medicine and tissue engineering apply the principles of cell transplantation, material science, and bioengineering to construct biological substitutes that will restore and maintain normal function in diseased and injured tissues. Neovascularization is promoted by bone marrow-derived endothelial progenitor cells that lead to the formation of entirely new vessels into ischemic tissue. With this knowledge, many therapeutical borders can be skipped. Diseases formerly uncontrolled can be corrected with stem cells to provide causal healing with regeneration processes. The 9th Leipziger Workshop combined with the 2nd International Workshop on SBC aimed to offer new methods in image cytometry and SBC for solutions in clinical research. It moved toward practical applications in clinics and the clinical laboratory. This development will be continued in 2005 at the upcoming Leipziger Workshop and the 3rd International Workshop on SBC.

Cardiovascular Diseases↗

Ultra high-speed sorting.

BACKGROUND: Cell sorting has a history dating back approximately 40 years. The main limitation has been that, although flow cytometry is a science, cell sorting has been an art during most of this time. Recent advances in assisting technologies have helped to decrease the amount of expertise necessary to perform sorting. METHODS: Droplet-based sorting is based on a controlled disturbance of a jet stream dependent on surface tension. Sorting yield and purity are highly dependent on stable jet break-off position. System pressures and orifice diameters dictate the number of droplets per second, which is the sort rate limiting step because modern electronics can more than handle the higher cell signal processing rates. RESULTS: Cell sorting still requires considerable expertise. Complex multicolor sorting also requires new and more sophisticated sort decisions, especially when cell subpopulations are rare and need to be extracted from background. High-speed sorting continues to pose major problems in terms of biosafety due to the aerosols generated. CONCLUSIONS: Cell sorting has become more stable and predictable and requires less expertise to operate. However, the problems of aerosol containment continue to make droplet-based cell sorting problematical. Fluid physics and cell viability restraints pose practical limits for high-speed sorting that have almost been reached. Over the next 5 years there may be advances in fluidic switching sorting in lab-on-a-chip microfluidic systems that could not only solve the aerosol and viability problems but also make ultra high-speed sorting possible and practical through massively parallel and exponential staging microfluidic architectures.

Aerosols↗

Systems biology and clinical cytomics: The 10th Leipziger Workshop and the 3rd International Workshop on Slide-Based Cytometry, Leipzig, Germany, April 2005.

Despite very significant technical and software improvements in flow cytometry (FCM) since the 1980's, the demand for a cytometric technology combining both quantitative cell analysis and morphological documentation in Cytomics became evident. Improvements in microtechnology and computing permit nowadays similar quantitative and stoichiometric single cell-based high-throughput analyses by microscopic instruments, like Slide-Based Cytometry (SBC). SBC and related techniques offer unique tools to perform complex immunophenotyping, thereby enabling diagnostic procedures during early disease stages. Multicolor or polychromatic analysis of cells by SBC is of special importance not only as a cytomics technology platform but also because of low quantities of required reagents and biological material. The exact knowledge of the location of each cell on the slide permits repetitive restaining and reanalysis of specimens. Various separate measurements of the same specimen can be ultimately fused to one database increasing the information obtained per cell. Relocation and optical evaluation of cells as typical SBC feature, can be of integral importance for cytometric analysis, since artifacts can be excluded and morphology of measured cells can be documented. Progress in cell analytic: In the SBC, new horizons can be opened by the new techniques of structural and functional analysis with the high resolution from intracellular and membrane (confocal microscopy, nanoscopy, total internal fluorescence microscopy (TIRFM), and tissue level (tissomics), to organ and organism level (in vivo cytometry, optical whole body imaging). Predictive medicine aims at the detection of changes in patient's state prior to the manifestation of the disease or the complication. Such instances concern immune consequences of surgeries or noninfectious posttraumatic shock in intensive care patients or the pretherapeutic identification of high risk patients in cancer cytostatic therapy. Preventive anti-infectious or anti-shock therapy as well as curative chemotherapy in combination with stem cell transplantation may provide better survival chances for patient at concomitant cost containment. Predictive medicine-guided optimization of therapy could lead to individualized medicine that gives significant therapeutic effect and may lower or abrogate potential therapeutic side effects. The 10th Leipziger Workshop combined with the 3rd International Workshop on SBC aimed to offer new methods in Image- and Slide-Based Cytometry for solutions in clinical research. It moved towards practical applications in the clinics and the clinical laboratory. This development will be continued in 2006 at the upcoming Leipziger Workshop and the International Workshop on Slide-Based Cytometry.

Cytophotometry↗