Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Contraception Continuation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

Maintaining family planning acceptance levels through development incentives in Northeastern Thailand.

The results of a two-year longitudinal study of the effect that development program incentives have upon family planning in Northeastern Thailand are presented. These incentives, implemented by the Population and Community Development Association, Thailand, included animal raising and agricultural, home industry, and environmental activities. An experimental design including baseline and follow-up surveys supplemented by a continuous monitoring system was utilized to test hypotheses on the family planning impacts of the incentives. Findings indicate that the incentives contributed significantly to the maintenance of high levels of family planning practice through the program period 1982-1984.

Contraception Behavior↗

A two-year experience with Norplant implants in Assiut, Egypt.

This report describes the two-year experience of 250 acceptors of NORPLANT implants and 100 TCu-380-Ag IUD acceptors in Assiut, Egypt. The two-year net continuation rate was 67.9 per 100 for implant users and 52.3 per 100 for IUD users. The most important cause for NORPLANT removal was the disruption of menstrual rhythm. However, by the end of the second year, three-quarters of NORPLANT users had monthly menstrual periods and about 60 percent described the amount of blood loss as average, 15 percent as decreased, 15 percent as increased and 10 percent as variable. About 88 percent of the NORPLANT acceptors rated their experience with the contraceptive as good or excellent.

Adult↗

Four-year experience in a randomized study of the Gyne T 380 Slimline and the Standard Gyne T 380 intrauterine copper devices.

Performance of the Slimline and Standard models of the Gyne T 380 were measured through four years in a comparative study initially involving 996 women, seventy percent of whom were randomized to the Slimline device. Cumulative pregnancy rates of Slimline users were 0.3 +/- 0.2 per 100 both at three and at four years, as compared with rates of 1.5 +/- 0.9 and 3.8 +/- 1.7 at the same intervals for users of the Standard model (P > .05). The four-year explusion rate of the Slimline, 8.6 +/- 1.3 per 100, was significantly higher than the comparable rate of the Standard model, 4.4 +/- 1.6 (P < .05). The two Gyne T* models did not differ in continuation rates. First time IUD users, however, had substantially lower continuation rates than did former users (P < .001), in consequence of their relative youth and desire to have additional children. Other performance measures did not differ importantly by device.

Adolescent↗

Tailoring family planning services to the special needs of adolescents.

Experimental service protocols tailored to the needs of teenage family planning patients were developed that emphasized indepth counseling, education geared to an adolescent's level of development, and the provision of reassurance and social support. These protocols were tested against usual service delivery practices in a study involving 1,261 patients under 18 years of age at six nonmetropolitan family planning clinics. A comparison with teenagers obtaining services at control sites found that six months after their first clinic visit, patients at the experimental sites were more likely to be using a method, were less likely to experience difficulty in dealing with problems, were more likely to continue using their method despite problems and had learned more during the educational session. Teenage patients at the experimental clinics were also less likely to have become pregnant within one year than those who went to control clinics. Attrition during the year following the first study visit was similar among both groups; patient satisfaction was very high, and equivalent at experimental and control sites. The data show that the extra time and effort required to meet the special needs of teenagers is justified by their improved contraceptive use, greater knowledge and lower pregnancy rates.

Adolescent↗

A randomized trial of three copper IUDs (MLCu250, MLCu375 and Nova-T).

A randomized prospective trial of three copper IUDs, Nova-T, MLCu375 and MLCu250, including 200 of each, is presented. Insertion was done at the hospital outpatient clinic on normally menstruating women and on women in puerperio. Follow-up was scheduled after 12, 24 and 36 months. Pregnancy rates were low for all 3 models. Pearl indices after 3 years were 0.5, 0.9 and 0.8 for Nova-T, MLCu375 and MLCu250 respectively (NS). Abnormal bleeding and/or pain was the most frequent termination cause. Minor differences in the termination rates because of abnormal bleeding and/or pain were found and are discussed. The continuation rates based on all medically relevant IUD removals were 74%, 73% and 81% after 3 years for Nova-T, MLCu375 and MLCu250 respectively. No important difference in clinical performance between the three copper IUDs could be demonstrated.

Clinical Trials as Topic↗

Acceptance, efficacy, and side effects of Norplant implants in four counties in north China.

This report attempts to present a comprehensive analysis of the acceptability, side effects, and efficacy of Norplant as used in rural areas, based on a field experiment conducted in four counties in Hebei and Shandong Provinces, China. The initial acceptance of Norplant was relatively high but waned after the first year in three of the four counties. Compared with clinical trials, the current study shows a lower prevalence but similar patterns of side effects. The pregnancy rate during the first two years of use is similar to that found in large-scale clinical trials conducted in China, but discontinuation due to other reasons is lower. A three-level logistic regression analysis shows significant variation in the probability of discontinuation due to side effects across counties. It also indicates an increase in the conditional probability of discontinuation with the duration of use. Whereas introducing Norplant and achieving a very low failure rate and high continuation rate in rural areas is feasible under diverse socioeconomic conditions, the results vary significantly across different areas. Particular attention should be paid to the local factors that may affect results.

Adult↗

Two-year rates for Nova T and Copper T in a comparative study.

A random assignment comparative study between Nova T and Copper T 200 after two years of use revealed that the Nova T resulted in a significantly lower pregnancy rate than the Copper T. The study was performed simultaneously in Denmark, Sweden and Finland. The pregnancy rate in Nova T users was lower than in Copper T users in every country and in every age and parity group. There was no clinic effect in the pregnancy rate of Nova T users. The other termination rates of these two devices were not significantly different. The first segment continuation rates at two years of postmenstrual insertions were 64.7 for Nova T and 65.5 for Copper T 200. It seems that Nova T is an improved copper-releasing IUD.

Actuarial Analysis↗

An evaluation of the TCu 380Ag and the Multiload Cu375.

The TCu 380Ag (Outokumpu Oy, Pori, Finland) and the Multiload Cu375 (Multilan, Organon, Oss, The Netherlands) were evaluated in 1477 women in a multicenter clinical trial. The intrauterine devices showed similar, low-event rates. Cumulative life-table pregnancy rates were less than 1.0, and continuation rates were approximately 90 per 100 women at 1 year after insertion. The risk of subsequent hospitalization or pelvic infection was low.

Adult↗

A comparison of the delta copper T and the copper T 200 in Bologna, Italy.

An analysis is presented of a comparative study of the Delta T and Copper T 200 IUDs. A total of 195 postabortion insertions was performed between March 1981 and August 1982. All insertions were performed with an inserter. Primary bleeding/pain complaints after insertion were largely related to intermenstrual problems, with spotting the most frequently reported. Nine women had their devices removed for PID. One pregnancy occurred at ten months in the Delta T group. Both groups had one expulsion/displacement. Eight devices in each group were removed for bleeding/pain. Two women in the TCu group had their devices removed for personal reasons. The 6-months continuation rates for the two groups were 85.5 for the Delta T group and 82.2 for the TCu group. The 6-months follow-up rate for the Delta T group was 39.4 and 38.8 for the TCu group.

Abortion, Induced↗

Clinical experience with the GYNE-T 380 postpartum intrauterine device.

OBJECTIVE: The insertion of conventional intrauterine devices (IUDs) during the 1st 10 days after delivery is associated with a high rate of expulsions. DESIGN: The GYNE-T 380 (Ortho Pharmaceutical [Canada] Ltd., Toronto, Ontario, Canada) IUD was modified by the addition of a loose loop of knotted biodegradable no. 2 catgut to the top of the IUD (GYNE-T 380 postpartum IUD). After delivery, a special inserter was used to imbed the knotted portion of the loop into the myometrium of the uterine fundus. PATIENTS, PARTICIPANTS: This modified IUD was evaluated in a phase II trial involving 190 women at four clinical sites. MAIN OUTCOME MEASURES: There were no pregnancies during the 1st year of the study. The continuation rate was 74 per 100 women and a life table expulsion rate of 9.6 and 13.3 per 100 women was observed at 6 and 12 months, respectively. RESULTS: Complications associated with the insertion and the use of this IUD were minimal. Large scale trials evaluating this IUD are in progress.

Equipment Design↗

A randomized trial of the Gyne T 380 and Gyne T 380 Slimline Intrauterine Copper devices.

To facilitate manufacture and insertion of the Gyne T 380 IUD, design changes were instituted. Copper collars were seated flush at the ends of the horizontal crossbar of the device. A randomized study of the Gyne T 380 Slimline, the new design, was undertaken in comparison with the standard Gyne T 380. A total of 996 women were enrolled, with 698 Slimline insertions and 298 of the standard Gyne T. No statistically significant difference in ease of insertion or in performance was detected between the models. At one year, the pregnancy rate of each model was below 0.5 per 100 and the continuation rate was 79-80 per 100. Pelvic inflammatory disease or endometritis was found in one percent of subjects in the first year. This is the seventh multicenter randomized study of a collared T IUD with 380 mm2 of copper surface. In all seven, the one-year gross pregnancy rate has been 1.2 per 100 or lower.

Adult↗

Acceptability of Norplant-2 rods as a method of family planning.

The Norplant-2 rod system consists of two silastic rods in which levonogestrel has been incorporated with the polymer. The continuation rate at the end of five year was 62%. No accidental pregnancies occurred throughout the five years of use. The post-removal conception rate in women desiring pregnancy was 70.8% at the end of two years. The majority of acceptors were happy with the rods and 86.8% expressed the desire to have another set of implants inserted following removal of the first set. The study shows the Norplant-2 rod system to be a well accepted method of family planning.

Adult↗

Fundamental elements of the quality of care: a simple framework.

This article argues for attention to a neglected dimension of family planning services--their quality. A framework for assessing quality from the client's perspective is offered, consisting of six parts (choice of methods, information given to clients, technical competence, interpersonal relations, follow-up and continuity mechanisms, and the appropriate constellation of services). The literature is reviewed regarding evidence that improvements in these various dimensions of care result in gains at the individual level; an even scarcer body of literature is reviewed for evidence of gains at the level of program efficiency and impact. A concluding section discusses how to make practical use of the framework and distinguishes three vantage points from which to view quality: the structure of the program, the service-giving process itself, and the outcome of care, particularly with respect to individual knowledge, behavior, and satisfaction with services.

Contraception↗

Use effectiveness of the Creighton model ovulation method of natural family planning.

OBJECTIVE: To determine the use effectiveness of the Creighton model ovulation method in avoiding and achieving pregnancy. DESIGN: Prospective, descriptive. SETTING: A natural family planning clinic at a university nursing center. PARTICIPANTS: Records and charts from 242 couples who were taught the Creighton model. The sample represented 1,793 months of use of the model. MAIN OUTCOME MEASURE: Creighton model demographic forms and logbook. RESULTS: At 12 months of use, the Creighton model was 98.8% method effective and 98.0% use effective in avoiding pregnancy. It was 24.4% use effective in achieving pregnancy. The continuation rate for the sample at 12 months of use was 78.0%. CONCLUSION: The Creighton model is an effective method of family planning when used to avoid or achieve pregnancy. However, its effectiveness depends on its being taught by qualified teachers. The effectiveness rate of the Creighton model is based on the assumption that if couples knowingly use the female partner's days of fertility for genital intercourse, they are using the method to achieve pregnancy.

Adult↗

Twelve-month comparative multicenter study of the TCu 380A and ML 250 intrauterine devices in Bangkok, Thailand.

The long-term effectiveness of the copper-bearing intrauterine device (IUD) has been documented. This paper reports 12-month results from a multiyear comparative study of the Copper T (TCu) 380A and Multiload (ML) 250 IUD in Bangkok, Thailand, among 1396 women. Continuation of the assigned IUD was relatively high after 12 months of use, with continuation rates of 90.17 and 87.54 per 100 women, respectively. Whereas the accidental pregnancy rate was higher for the ML 250 IUD than for the TCu 380A IUD (1.0 and 0.2 per 100 women, respectively), this difference was not considered statistically significant (p < 0.69). The rate of IUD expulsion was significantly higher among women using the ML 250 IUD than for women using the TCu 380A IUD (4.61 and 2.40 per 100 women, respectively, p = 0.05).

Adult↗

Clinical and endocrinologic study of continuous levonorgestrel administration from subcutaneous solid polydimethylsiloxane rods.

Three solid polydimethylsiloxane (Silastic) rods containing levonorgestrel were inserted into the subcutaneous tissue of the volar aspect of the forearm of 8 women. Serum samples were drawn three times a week for 2 months and weekly thereafter for 2 years in 3 of the subjects. The other subjects had serum drawn during the twelfth and last treatment months. Levonorgestrel, estradiol and progesterone were measured in all samples. The subject kept a bleeding record. In comparison to an earlier clinical trial in which 6 hollow capsules of Silastic filled with levonorgestrel were used, the 3 solid levonorgestrel-containing rods provided higher serum levels of levonorgestrel, fewer serum estradiol peaks, only a single episode of ovulation and better bleeding performance.

Adult↗

Correlation of endocrine profiles with bleeding patterns during use of Nestorone contraceptive implants.

The relationship between ovarian hormones and bleeding patterns during continuous progestin contraception was studied in 29 women who used Nestorone (NES) releasing implants. Oestradiol and progesterone were measured in blood samples taken twice a week for 6 consecutive weeks, during months 6, 12, 18 and 24 of implant use. Retrospectively, the association between hormonal concentrations and bleeding patterns was evaluated. Twenty-four short (</= 24 days), 36 normal (25-35 days), 27 long (36-90 days) and nine episodes of amenorrhoea, as well as 28 periods of prolonged bleeding, were identified. Short cycles, periods of prolonged bleeding and amenorrhoea were characterized by low oestradiol concentrations. Bleeding after a normal or long cycle regularly occurred after a rise and fall of oestradiol or oestradiol and progesterone. The duration of bleeding was directly and significantly associated with the highest concentration of oestradiol in the previous 15 days in anovulatory cycles. Luteal activity was associated with shorter duration of bleeding. Periods of prolonged bleeding were usually initiated with a drop in oestradiol and over half ended with an increase in oestradiol. It was concluded that changes in endogenous hormone have a significant influence over the bleeding pattern during use of NES implants.

Adolescent↗

Immediate post-abortal insertion of the frameless GyneFix IUD: initial experience in China.

The promising results obtained with the frameless GyneFix IUD for interval insertion led to the belief that the technology could be useful for immediate post-abortal application to reduce the number of induced and repeat abortions. IUDs have many advantages and the method is acceptable and safe. However, side effects and expulsion of conventional IUDs remain a problem. In an attempt to minimise these problems, the frameless GyneFix IUD was developed. Clinical studies conducted over the past 14 years have shown that the principles on which the device is based are valid. An increasing bulk of clinical evidence shows that the design characteristics of the device (fixed, frameless and flexible) are responsible for the low expulsion, high effectiveness, and high tolerance and continuation rates.1 Experience with the frameless IUD in China since 1989 confirms the international experience with the device. The present communication is a second report from China with the GyneFix IUD. In the present study the GyneFix IUD is inserted immediately following termination of pregnancy of less than 10 weeks amenorrhea. It is concluded that immediate post-abortal insertion of the frameless IUD is easy and safe, and appears to be as reliable and as effective as when it is inserted at interval. The GyneFix IUD could, therefore, constitute an important new option in the prevention of abortion.

Abortion, Induced↗