Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLATES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

Microbicidal efficacy of ozonated water against Candida albicans adhering to acrylic denture plates.

BACKGROUND/AIMS: Ozone is known to act as a strong antimicrobial agent against bacteria, fungi, and viruses. We examined the effect of ozonated water on Candida albicans on acrylic denture plate. METHODS: The heat-cured acrylic resins were cultured with C. albicans. After treatment of flowing ozonated water, the number of attached C. albicans was counted. In some experiments, the test samples were treated with ozonated water in combination with ultrasonication. RESULTS: After exposure to flowing ozonated water (2 or 4 mg/l) for 1 min, viable C. albicans cells were nearly nonexistent. The combination of ozonated water and ultrasonication had a strong effect on the viability of C. albicans adhering to the acrylic resin plates. There were no significant differences in antimicrobial activity against C. albicans between plates immersed in ozonated water with ultrasonication and those treated with commercially available denture cleaners. In addition, electron microscopic analysis revealed that small amounts of C. albicans remained on the plate after exposure to flowing ozonated water or immersion in ozonated water with ultrasonication. CONCLUSION: Our results suggest that application of ozonated water may be useful in reducing the number of C. albicans on denture plates.

Acrylic Resins↗

In vitro new dialysis protocol to assay the antiseptic properties of a quaternary ammonium compound polymerized with denture acrylic resin.

AIMS: To develop an in vitro protocol in order to assess the antiseptic properties of a quaternary ammonium compound polymerized with acrylic denture resin base, using experimental resin discs and dialysis membranes. METHODS AND RESULTS: Experimental acrylic resin discs were polymerized with Poly 202063A, an ammonium compound (2-50%). Antiseptic properties were assayed against two reference strains (Escherichia coli, Staphylococcus aureus) and a laboratory strain (Candida albicans), using three different conditions (test A, B and C). In test A, according to classical protocols the resin discs were first soaked in large volumes of microbial inoculum (45 ml). An original dialysis protocol was then designed to recreate the small biofilm volume on the prosthetic surface. In test B, discs and bacterial inoculum (600 microl) were introduced in a dialysis bag and dialysed against a sterile buffer. A bactericidal effect was observed against E. coli and Staph. aureus (<0.1% viable cells in initial bacterial suspension). A dose-dependent fungistatic effect was observed against C. albicans. Finally, in test C discs and sterile buffer (600 microl) were introduced in a dialysis bag and dialysed against microbial inoculum. Reduced activity was found outside the dialysis bag, demonstrating that free ammonium was able to diffuse through the dialysis membrane, displaying antiseptic properties. CONCLUSIONS: The present protocol demonstrated that a quaternary ammonium compound remains efficient after heat polymerization with an acrylic denture base resin, both in immediate and distant microbial environments. SIGNIFICANCE AND IMPACT OF THE STUDY: Such removable prosthetic devices with intrinsic antiseptic properties would contribute to improve the long-term management of denture stomatitis.

Acrylic Resins↗

A comparison of microwave and dry-heat curing methods on the bond strength of silicone facial materials applied to acrylic resin.

PURPOSE: This study compared two curing methods (microwave irradiation and dry heat) on the tensile bond strength of silicone facial materials to cured acrylic resin. The facial materials studied were Mollomed, Silskin II, MDX4-4210, and A-2186. MATERIALS AND METHODS: The samples were processed with microwaves for 13 minutes at 90 W plus 2 minutes at 500 W and dry heat for 3 hours at 100 degrees C to cured acrylic resin. Facial materials 3-mm thick were processed between two half-dumbbells of acrylic resin. The bonding surfaces were treated with a primer. The samples were placed in tension until failure. RESULTS: The results showed that the bond strength was affected by the type of silicone material and not by the curing methods used. CONCLUSIONS: Mollomed had the highest bond strength of all materials tested. MDX4-4210 and A-2186 showed the lowest, and Silskin II had intermediate bond strength. Microwave irradiation has the potential of saving time, energy, and resources during the fabrication of facial prostheses, but further laboratory studies and clinical trials are indicated.

Acrylic Resins↗

Metabolic routing towards polyhydroxyalkanoic acid synthesis in recombinant Escherichia coli (fadR): inhibition of fatty acid beta-oxidation by acrylic acid.

Heterologous expression of the phaC1 gene from Pseudomonas aeruginosa, which encodes one of the polyhydroxyalkanoic acid synthases, in Escherichia coli impaired in fatty acid beta-oxidation results in polyhydroxyalkanoic acid accumulation when cells were cultivated on fatty acids. We evaluated the application of the fatty acid beta-oxidation inhibitor acrylic acid as a tool to channel intermediates of beta-oxidation to polyhydroxyalkanoic acid synthesis. Various E. coli strains affected in fatty acid metabolism and the wild-type strain harboring plasmid pBHR71 were analyzed with respect to polyhydroxyalkanoic acid accumulation in the presence of acrylic acid. The E. coli fadR mutant RS3097 revealed the strongest polyhydroxyalkanoic acid accumulation. The optimum inhibitory concentration of acrylic acid was 0.24 mg ml-1 and caused efficient channeling of intermediates of beta-oxidation to polyhydroxyalkanoic acid synthesis. Under these conditions and grown on decanoate E. coli RS3097 harboring plasmid pBHR71 revealed a polyhydroxyalkanoic acid accumulation contributing to about 60% of cellular dry weight.

Acrylates↗

Sensitizing potential of 14 mono (meth) acrylates in the guinea pig.

The aim of this study was to investigate differences in the sensitizing potential of 14 mono(meth)acrylates, when tested by the guinea pig maximization test (GPMT) and Freund's complete adjuvant test (FCAT) with an identical, intradermal induction concentration. A new grading classification of the sensitization potential is proposed. Mono(meth)acrylates show a wide range of sensitizing potential. Compared with other (meth)acrylates, methyl methacrylate is a moderate sensitizer. Attention was paid to concomitant sensitization of additives. In 9 of 16 FCATs, concomitant sensitization occurred to the inhibitors hydroquinone and p-methoxyphenol.

Acrylates↗

Contact sensitivity to acrylate compounds in guinea pigs.

As reports of contact dermatitis in humans due to acrylate compounds have increased considerably in recent years, it was decided to investigate the ability of these chemicals to evoke contact sensitivity skin reactions in guinea pigs. 21 different acrylate and methacrylate compounds were scanned for their ability to induce contact sensitivity, using 5 different sensitization protocols. Contact reactions of varying intensities were produced to all the mono-, di- and triacrylates tested. However, it was not possible to sensitize guinea pigs to any methacrylates. It would appear that guinea pigs cannot be contact sensitized to acrylate chemicals that are substituted on carbon 2.

Acrylates↗

A liquid film-forming acrylate for peri-wound protection: a systematic review and meta-analysis (3M Cavilon no-sting barrier film).

To undertake a systematic review of all reliable evaluations of the clinical performance and cost-effectiveness of a film-forming liquid acrylate in the protection of the chronic ulcer peri-wound skin. Results from searches were scrutinised by two reviewers to identify possible randomised controlled trials and full reports of these were obtained. Details of eligible studies were extracted and summarised independently by two reviewers using a data extraction sheet. Meta-analysis was used to combine the results of trials where the interventions and outcome measures were sufficiently similar. A total of nine eligible studies were identified. The review reveals that a liquid-film forming acrylate (Cavilon no-sting barrier film, 3M, Minneapolis, MN, USA) is a safe and effective skin barrier to protect the peri-wound area of chronic ulcers. There is no difference between the protective properties of different barrier methods that are used to protect the peri-wound skin around chronic ulcers. Compared with no treatment or a placebo, this liquid film-forming acrylate has a significant impact on the integrity of the peri-wound skin. In addition, it has significant benefits in terms of pain control and patient comfort, and its use may reduce nursing time.

Acrylates↗

Flexural properties of glass fibre reinforced acrylic resin polymers.

BACKGROUND: In recent years, glass fibres have been used to strengthen denture base resins. A major difficulty in using reinforcing fibres with multiphase acrylic resins, such as powder liquid resins, is inadequate impregnation of the fibres with the resin. METHODS: This investigation examined the reinforcing effect of glass fibres on the fracture resistance and flexural strength of acrylic denture base resins. Eighty identical specimens were formed in specially designed moulds in accordance with the manufacturer's recommendations. The four experimental groups were prepared and these consisted of conventional acrylic resin and the same resin reinforced with glass fibres. Ten specimens were fabricated in a standardized fashion for each experimental group. Flexural strength was tested using a 3-point universal testing machine. RESULTS: In this study, statistically significant differences were found in the flexural strength of the specimens (P < 0.05). The injection-moulded, fibre-reinforced group had significantly lower flexural strength than the injection-moulded group (P < 0.001), strength than the microwave-moulded, fibre-reinforced group (P < 0.001), and the microwave-moulded, fibre-reinforced group had lower flexural strength than the microwave-moulded group. The fracture resistance was significantly higher in the injection-moulded, fibre-reinforced group than in the injection-moulded group (P < 0.05), and the fracture resistance was significantly higher in the microwave-moulded, fibre-reinforced group than in the microwave-moulded group. CONCLUSION: Within the limitations of this study, the flexural strength of heat-polymerized PMMA denture resin was improved after reinforcement with glass fibres. It may be possible to apply these results to distal extension partial and complete denture bases.

Acrylic Resins↗

Nitrile hydratase and amidase from Rhodococcus rhodochrous hydrolyze acrylic fibers and granular polyacrylonitriles.

Rhodococcus rhodochrous NCIMB 11216 produced nitrile hydratase (320 nkat mg of protein(-1)) and amidase activity (38.4 nkat mg of protein(-1)) when grown on a medium containing propionitrile. These enzymes were able to hydrolyze nitrile groups of both granular polyacrylonitriles (PAN) and acrylic fibers. Nitrile groups of PAN40 (molecular mass, 40 kDa) and PAN190 (molecular mass, 190 kDa) were converted into the corresponding carbonic acids to 1.8 and 1.0%, respectively. In contrast, surfacial nitrile groups of acrylic fibers were only converted to the corresponding amides. X-ray photoelectron spectroscopy analysis showed that 16% of the surfacial nitrile groups were hydrolyzed by the R. rhodochrous enzymes. Due to the enzymatic modification, the acrylic fibers became more hydrophilic and thus, adsorption of dyes was enhanced. This was indicated by a 15% increase in the staining level (K/S value) for C. I. Basic Blue 9.

Acrylic Resins↗

Use of the modified acrylic external fixator in 54 dogs and 28 cats.

This paper describes the use of acrylic resin instead of a Kirschner clamp for treating bone fractures. The technique is cheaper than using Kirschner external skeletal fixator and allows greater flexibility for pin placement. It is also less prone to self mutilation by dogs than the entirely acrylic external fixator. The modified acrylic fixator gave results similar to those obtained with the Kirschner external fixator, when used in 54 dogs and 28 cats.

Acrylic Resins↗

A new acrylic tissue adhesive for conjunctival surgery: experimental study.

PURPOSE: To evaluate the clinical efficacy and the clinical and histopathologic tolerance of a new acrylic tissue adhesive (ADAL-2) versus 8/0 polyglactin sutures (Vicryl) for its use in conjunctival surgery. METHOD: Experimental study performed on New Zealand albino rabbits. The animals were divided into two groups. Surgery consisted of a conjunctival peritomy of 8 mm in the superior limbus followed by extensive subconjunctival dissection and creation of a flap by two radial cuts. The conjunctiva was then attached to the limbus again by the proposed acrylic tissue adhesive (ADAL-2) or 8/0 polyglactin suture depending on the group. Clinical efficacy of the closure of the conjunctival wound, either with adhesives or sutures, and the clinical and histopathologic tolerance were also evaluated 1, 7, 28 and 42 days after surgery. RESULTS: Both conjunctival surgical closure methods were found to be equal in efficacy concerning their ability to fix the conjunctiva to the limbus. There were no significant clinical and histopathologic tolerance differences between the new tissue adhesive investigated (ADAL-2) and 8/0 polyglactin sutures (Vicryl). Histopathology showed no presence of the adhesive 28 days postoperatively. CONCLUSIONS: ADAL-2 tissue adhesive is an efficient conjunctival closure method, very well tolerated by the ocular surface. Its sealing efficiency and its tolerance are similar to 8/0 polyglactin sutures. This new acrylic adhesive has a potential as an alternative for surgical conjunctival sealing in ophthalmic surgery.

Acrylates↗

Distortion behavior of heat-activated acrylic denture-base resin in conventional and long, low-temperature processing methods.

There have been many reports on fatal distortion of heat-activated acrylic denture-base resin which is still widely used in the field of removable prosthodontics. However, these reports have failed to report quantitatively on polymerization and thermal shrinkage factors. In the present study, we attempted to verify that the shrinkage of heat-activated acrylic denture-base resin was caused mainly by thermal contraction after processing. Furthermore, we examined the degree of distortion resulting from long, low-temperature processing, and compared the results with that of the conventional method. The strain gauge and thermo-couple were embedded in a specimen at the time of resin packing. The measurement started from the beginning of processing and continued until the specimen was bench-cooled and immediately before and after it was de-flasked, as well as during seven-day immersion in water at 37 degrees C. The resin expanded when processed by the conventional method. Meanwhile, mild shrinkage, possibly polymerization shrinkage, was observed when the resin was processed by the low-temperature method. This suggested that polymerization shrinkage was compensated for by thermal expansion during processing by the conventional method. Moreover, the shrinkage strains in the period from the completion of processing to immediately after de-flasking, in both the conventional and low-temperature methods, were identical to the theoretical value of thermal shrinkage which we obtained by multiplying the linear coefficients of thermal expansion by temperature differences. The shrinkage strain in the specimen processed by the low-temperature method, measured from the end of processing to immediately after de-flasking, averaged 64% of that in the specimen processed by the conventional method. The results revealed quantitatively that the shrinkage of heat-activated acrylic denture-base resin was mainly thermal shrinkage, and demonstrated the advantage of the low-temperature method in reducing thermal shrinkage.

Acrylic Resins↗

Tripropylene glycol diacrylate but not ethyl acrylate induces skin tumors in a twenty-week short-term tumorigenesis study in Tg.AC (v-Ha-ras) mice.

The toxicity of the esters of acrylic acid are poorly understood even though significant human exposure occurs. To conduct rapid comparative short-term bioassays, we used the Tg.AC (v-Ha-ras) transgenic mouse model to determine the toxicity and potential carcinogenicity of tripropylene glycol diacrylate (TPGDA) alone and in a reference formulated ultraviolet radiation curable lacquer (Lacquer A), which is used in the ultraviolet radiation curable surface coatings. For comparison, ethyl acrylate (EA) was used as a reference acrylate. Insertion of the zeta-globin promoted v-Ha-ras transgene into the FVB mouse genome (Tg.AC) introduced a defined genetic lesion, which is critical but insufficient by itself to induce benign or malignant tumors in the skin unless activated. Activation and expression of the transgenic ras oncoprotein in this mouse line induces a dose-related increase in papillomas (skin reporter phenotype) within weeks. Based on dose-related increases in skin hyperplasia following dermal exposure to EA, TPGDA, or Lacquer A (applied equimolar for TPGDA concentration), the dosing regimen was selected. Starting at 12 wk of age, the agents were administered topically (200 microliters of acetone vehicle) 3 times/wk for 20 wk to the shaved dorsal skin of female Tg.AC mice (n = 10/group). TPGDA and reference Lacquer A (equimolar for TPGDA) at 5 or 10 mumoles/mouse but not EA (60, 300, or 600 mumoles/mouse) or TPGDA or Lacquer A at 1 mumole/mouse induced a dose-related increase in papillomas between 6 and 12 wk of treatment that reached a maximum number of papillomas per mouse between 19 and 20 wk of treatment. These results indicate that TPGDA is significantly more potent than EA for inducing the skin reporter phenotype and may be predicted to be carcinogenic in long-term cancer bioassays at the site of contact.

Acrylates↗

Visually significant opacification of hydrophilic acrylic intraocular lenses--a clinico-pathological analysis.

PURPOSE: To describe the clinic-pathological analysis of the visually significant opacification of the Cirrus International Hydroflex foldable hydrophilic acrylic intraocular lens (IOL) (model SC600-2, Medical Developmental Research Inc., Clearwater, Florida) and to highlight that this IOL is the same model as the Acryflex SC600-2 IOL, by the same manufacturer. METHODS: Retrospective review of five eyes of four patients with opacification of their Cirrus International Hydroflex foldable hydrophilic acrylic IOLs (model SC600-2) after uncomplicated phacoemulsification and IOL implantation. Two IOLs were explanted from two patients 14 to 24 months after initial implantation. Each explanted lens was divided into equal halves, one half for scanning electron microscopy (SEM) study and the other half for transmission electron microscopy (TEM) examination. SEM and TEM samples were also subjected to energy dispersive X-ray analysis (EDX). RESULTS: The IOL opacification was detected 14 to 24 months after uncomplicated phacoemulsification and IOL implantation. EDX analysis showed that the crystals contained calcium and phosphorus, presumably calcium phosphate. CONCLUSIONS: The Cirrus International Hydroflex foldable hydrophilic acrylic IOL (model SC600-2) is associated with opacification, that appeared worse centrally than peripherally. This is the same model as the Acryflex SC600-2 IOL, made by the same manufacturer. The opacification consists of calcium and phosphate.

Acrylic Resins↗

Exchange technique for opacified hydrophilic acrylic intraocular lenses.

PURPOSE: To report an exchange technique for opacified hydrophilic acrylic intraocular lenses (IOLs). METHODS: . Twenty patients with two different types of opacified hydrophilic acrylic IOLs underwent IOL exchange by a single surgeon. Circumferential enlargement of the pre-existing capsulorrhexis was a critical step of the procedure, and resulted in expression of the IOL with minimal traction to the capsule. Implantation of an in-the-sulcus IOL followed. Surgical technique, complications, and visual outcome are discussed. RESULTS: Time from the initial cataract operation varied from 15 to 61 months (mean 30.5), and in all cases marked fibrosis was encountered. Eighteen patients had uncomplicated IOL exchange. Posterior capsule rupture occurred in two cases. Vision improved in 16 cases, remained unchanged in 3 cases, and deteriorated in 1 case. CONCLUSIONS: IOL exchange of opacified hydrophilic acrylic IOLs is a particularly challenging procedure due to extensive fibrosis. Circumferential enlargement of the pre-existing capsulorrhexis significantly facilitates the mobilization of the IOL from its fibrous pocket, with the use of minimal forces. Thus, the risk of zonular dehiscence or posterior capsule rupture is minimized.

Acrylic Resins↗

Preparation and characterization of insulin-loaded acrylic hydrogels containing absorption enhancers.

The objectives of this study were to prepare insulin-loaded acrylic hydrogel formulations containing various absorption enhancers, to perform in vitro and in vivo characterization of these formulations, and to evaluate the factors which affecting insulin availability on rectal delivery of insulin using this hydrogel system. The acrylic block copolymer of methacrylic acid and methacrylate, Eudispert, was used to make the hydrogel formulations. As absorption enhancers, 2,6-di-O-methyl-beta-cyclodextrin (DM-beta-CyD), lauric acid (C12), or the sodium salt of C12 (C12Na), were incorporated into the hydrogels. In an in vitro release test, the release rate of insulin from the hydrogels decreased as the polymer concentration of the hydrogel increased. The addition of C12Na to the hydrogel further increased the insulin release rate, which was greater at higher concentrations of the enhancer. A portion of the C12Na was found to remain bound to the acrylic polymer in dissolution medium. Serum insulin levels were determined at various time points after the administration of insulin solution or insulin-loaded (50 units/kg body weight) Eudispert hydrogels containing 5% (w/w) of C12, C12Na, or DM-beta-CyD to in situ loops in various regions of the rat intestine. The most effective enhancement of insulin release was observed with formulations containing C12Na. The bioavailability of insulin from the hydrogels was lower than that from the insulin solutions. Hydrogel formulations containing 7% or 10% Eudispert remained in the rectum for 5 h after rectal administration. However, the 5% (w/w) C12Na solution stained with Evan's-blue had diffused out and the dye had reached the upper intestinal tract within 2 h. Finally, the rectal administration of insulin-loaded hydrogels, containing 4%, 7%, or 10% (w/w) Eudispert and 5% (w/w) of enhancer (C12, C12Na, or DM-beta-CyD) to normal rats was shown to decrease serum glucose concentrations. The greatest effect was found with insulin-loaded 7% (Eudispert) hydrogel containing C12Na which having cosiderable large insulin release rate and bioadhesive characteristics.

Acrylates↗

Acrylic partial dentures.

Acrylic removable partial dentures are routinely used in everyday clinical practice. However, there is concern that if they are not correctly designed that damage may result to the soft and hard tissues leading to tooth loss. This article reviews the potential damage that may occur from the use of acrylic dentures. Methods of improving the design features and construction of acrylic RPDs to minimize damage and improve longevity of the remaining teeth will be demonstrated.

Acrylic Resins↗

Assessment of flexural strength and color alteration of heat-polymerized acrylic resins after simulated use of denture cleansers.

The purpose of this study was to assess flexural strength and color alteration of acrylic resins immersed in denture cleansers for different periods of time. Rectangular specimens (65 x 10 x 3mm) made from three heat-polymerized acrylic resins (Lucitone 550, QC-20 and Triplex) were assigned to three denture cleansers groups (Bony Plus, Corega Tabs and Efferdent Plus) and a control group (immersion in water). Soaking trials of 15 min and 8 h simulated 30 days of use. Flexural strength testing was carried out with 105 specimens on a universal testing machine. Color alterations were visually assessed by examination of photographs taken from 21 specimens. Flexural strength means (in MPa) were analyzed statistically by analysis of variance and Tukey's test at 5% significance level. There were significant differences (p<0.01) among the resins Lucitone (89.439 +/- 7.962), Triplex (88.024 +/- 5.167) and QC-20 (83.379 +/- 7.153). No significant differences (p>0.05) were found either among the denture cleansers (Bony Plus = 87.693 +/- 6.943; Corega Tabs = 86.955 +/- 7.114; Efferdent Plus = 86.195 +/- 7.865 and control = 86.536 +/- 7.012) or between the soaking periods (15 min = 86.875 +/- 7.625 and 8 h = 87.432 +/- 7.355) throughout the soaking cycles simulating 30 days of use. No color alterations were identified by visual examination. The findings of this study showed that chemical denture cleansers used according to the manufacturers' specifications did not cause flexural strength alterations or color changes in heat-polymerized acrylic resins submitted to soaking cycles that simulated 30 days of use.

Acrylic Resins↗