Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “surface modification”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Solid dosage form preparations from oily medicines and their drug release. Effect Of degree of surface-modification of silica gel on the drug release from phytonadione-loaded silica gels.

A surface-modified silica gel was produced to improve the surface affinity to an oily medicine, phytonadione (VK1). The effect of the degree of surface modification of the silica gel on the drug release behavior from the silica porous matrix was investigated. The silica gels were surface-modified using the silan coupling agent, 3-methacryloxypropyltrimethoxysilane (C7), octadecyltriethoxysilane (C18), or 3,3,3-trifluoropropyltrimethoxysilane (F3). A mixture of VK1 solution and surface-modified silica gel was evaporated under reduced pressure at room temperature, then the resulting powder was dried in vacuo. The degree of surface modification was evaluated based upon elementary analysis. The dissolution profiles of the samples were investigated in Japanese Pharmacopoeia XII, 1st fluid buffer (pH 1.2, 37+/-0.5 degrees C) containing 1.5% sodium lauryl sulfate. The FT-IR spectra of VK1-loaded surface-modified silica gels suggested that the amount of hydrogen-bonded VK1 with the silanol group on the gel surface decreased with increasing hydrophobicity of the silica gel. Since the modified group was rotating on the silica gel surface, and inhibited the adsorption of VK1 to the surface, the attractive molecular interaction between VK1 and the silica gel surface might decrease with increasing length of the modified functional group. However, the characteristics of the affinity of VK1 to the functional groups significantly differed among the groups. The VK1 release from the modified silica gels was initially rapid, slowed markedly after 1 h, and continued for more than 24 h. The amount of VK1 released from the modified surface silica gels by C7, C18 or F3 increased with increasing density of the surface modification group. The mean drug release moment (MDT) decreased with an increase in surface-modified group density.

Adsorption↗

On the surface modification of microchannels for microcapillary electrophoresis chips.

This paper presents systematic investigation of the microchannel surface properties in microCE chips. Three popular materials for microCE chips, polydimethylsiloxane (PDMS), quartz, and glass, are used. The zeta potentials of these microchannels are calculated by measuring the EOF velocity to evaluate the surface properties after surface modification. The hydrophobic PDMS is usually plasma-treated for microCE applications. In this study, a new method using a high-throughput atmospheric plasma generator is adopted to treat the PDMS surface under atmospheric conditions. In this approach, the cost and time for surface treatment can be significantly reduced compared with the conventional vacuum plasma generator method. Experimental results indicate that new functional groups could be formed on the PDMS surface after treatment, resulting in a change in the surface property. The time-dependent surface property of the plasma-treated PDMS is then measured in terms of the zeta potential. Results show that the surface property will reach a stable condition after 1 h of plasma treatment. For glass CE chips, two new methods for changing the microchannel surface properties are developed. Instead of using complicated and time-consuming chemical silanization procedures for CE channel surface modification, two simple and reliable methods utilizing organic-based spin-on-glass and water-soluble acrylic resin are reported. The proposed method provides a fast batch process for controlling the surface properties of glass-based CE channels. The proposed methods are evaluated using PhiX-174 DNA maker separation. The experimental data show that the surface property is modified and separation efficiency greatly improved. In addition, the long-term stability of both coatings is verified in this study. The methods proposed in this study show potential as an excellent solution for glass-based microCE chip surface modification.

Bacteriophage phi X 174↗

Surface modification of intravenous catheters to reduce local tissue reactions.

Surface modification of polymer materials used in intravascular catheters reduces the in vitro adhesion of plasma proteins involved in blood coagulation. Intravenous Teflon cannulae, native and surface-modified with ethyl hydroxyethyl cellulose, were compared using clinical examination and laser Doppler flowmeter (LDF) measurements of local cutaneous blood flow. Nine volunteers were simultaneously subjected to both types of cannulae for a period with a maximum of 4 d. Native Teflon catheters showed a larger incidence of catheter-associated tissue reactions, first demonstrated by early increases in laser Doppler recordings of skin blood flow. These results indicate that surface modification of polymer intravascular catheters attenuates tissue response against the foreign material and that altered LDF measurement precedes the clinical recognition of thrombophlebitis.

Adult↗

Surface modification of titanium with hydrothermal treatment at high pressure.

Surface modification of titanium was investigated by means of hydrothermal treatment with a maximum pressure of 6.3 MPa (280 degrees C temperature) in CaO solution or water to improve bioactivity and biocompatibility. As a result, calcium titanate was formed on the titanium surface. Moreover, titanium oxide and titanium hydroxide layers on the surface increased as temperature and pressure increased. The surface-modified titanium was also immersed in a simulated body fluid (SBF) to estimate its bioactivity. Needle-like apatite precipitation was observed on all hydrothermal-treated titanium surfaces after immersion in SBF for four weeks. In particular, the apatite precipitation of titanium treated with 6.3 MPa in CaO solution was clearer and larger in amount than those of all other hydrothermal-treated specimens. Further, the amount of precipitate corresponded to the thickness of the surface-modified layer and the amount of calcium in the surface layer. The results suggested that surface modification of titanium with high-pressure hydrothermal treatment seemed to improve bioactivity and biocompatibility.

Biocompatible Materials↗

Surface modification in microchip electrophoresis.

Different approaches and techniques for surface modification of microfluidic devices applied for microchip electrophoresis are reviewed. The main focus is on the improved electrophoretic separation by reducing analyte-wall interactions and manipulation of electroosmosis. Approaches and methods for permanent and dynamic surface modification of microfluidic devices, manufactured from glass, quartz and also different polymeric substrates, are described.

Acrylic Resins↗

A novel urethane containing copolymer as a surface modification additive for blood contact materials.

Surface modification to develop a biomolecules-presenting surface is of interest, both from a scientific and an industrial point of view. In this research, a penta-block-coupling polymer of warfarin-PEO-MDI-PEO-warfarin was specially designed as the surface modifying additive (SMA). The warfarin-modified polyurethane surfaces were then prepared by dip-coating method. Attenuated total reflection fourier transform infra-red (ATR-FTIR) spectra revealed that the urethane segments in the SMA could penetrate into the hard block of segmented polyurethane (SPU) via intermolecular hydrogen bonds. The X-ray photoelectron spectroscopy (XPS) results indicated that the intermolecular hydrogen bonds were strong enough to form stable warfarin-PEO composite surfaces in an aqueous environment. Fibrinogen and albumin adsorption onto unmodified and SMA-modified SPU was investigated by the (125)I-labeled method. The surface for attracting and reversibly binding albumin, which was proved to suppress the platelet adhesion and prolong the clotting time, has been developed by the simple coating of the novel SMA in SPU.

Journal Article↗

Surface modifications of alginate/poly(L-lysine) microcapsular membranes with poly(ethylene glycol) and poly(vinyl alcohol).

Three different surface modifications were conducted on the membranes of double-layer alginate/poly(L-lysine) microcapsules with tosyl chloride-activated poly(ethylene glycol), cyanuric chloride-activated poly(ethylene glycol) and tosyl chloride-activated poly(vinyl alcohol), separately. All these surface modifications strengthen the microcapsular membranes. Of the three surface-modified microcapsules, those treated with cyanuric poly(ethylene glycol) and tosylated poly(vinyl alcohol) have mechanical strength higher than that treated with tosylated poly(ethylene glycol). The permeabilities of the proteins were only slightly affected by the surface modifications. When IW32 erythroleukaemia cells were entrapped inside these microcapsules, cells proliferated to a density of (1.0-1.5) x 10(7) cells cm-3 after 7 d culturing compared with 2 x 10(6) cells cm-3 attained by free cell culturing. The intracapsular concentration of erythropoietin which was secreted by the IW32 cells accumulated to concentrations of 5-7 U cm-3. In addition, 3T3 cells were found to have a very low tendency to attach to the microcapsular membranes of all three surface-modified preparations.

3T3 Cells↗

Surface modification of nano-apatite by grafting organic polymer.

Since surface properties of hydroxyapatite (HA) play an important role in its performance, surface modification of HA has gained much attention from researchers. Silane coupling agents have been the focus of the research. In this study, an effective surface modification method was developed using hexamethylene diisocyanate as a coupling agent. Polyethylene glycol (Mw = 1500) was successfully coupled to the surface of nano-size apatite particles (nano-apatite). Various methods were used to characterize the surface-modified nano-apatite. Infra-red spectra confirmed the existence of a layer of polymer with both urethane and ether linkage on the surface of nano-apatite. The amount of grafted polymer as determined by total organic carbon analysis (TOC) and thermal gravimetric analysis (TGA) was about 20% in weight. Solid 1H MAS NMR spectra indicated that the amount of hydroxyl groups of nano-apatite was decreased by 7.7% after surface grafting reaction. It is concluded that the surface hydroxyl groups of nano-apatite have the reactivity towards isocyanate groups.

Carbon↗

Surface modification of silica nanoparticles to reduce aggregation and nonspecific binding.

In this article, a systematic study of the design and development of surface-modification schemes for silica nanoparticles is presented. The nanoparticle surface design involves an optimum balance of the use of inert and active surface functional groups to achieve minimal nanoparticle aggregation and reduce nanoparticle nonspecific binding. Silica nanoparticles were prepared in a water-in-oil microemulsion and subsequently surface modified via cohydrolysis with tetraethyl orthosilicate (TEOS) and various organosilane reagents. Nanoparticles with different functional groups, including carboxylate, amine, amine/phosphonate, poly(ethylene glycol), octadecyl, and carboxylate/octadecyl groups, were produced. Aggregation studies using SEM, dynamic light scattering, and zeta potential analysis indicate that severe aggregation among amine-modified silica nanoparticles can be reduced by adding inert functional groups, such as methyl phosphonate, to the surface. To determine the effect of various surface-modification schemes on nanoparticle nonspecific binding, the interaction between functionalized silica nanoparticles and a DNA chip was also studied using confocal imaging/fluorescence microscopy. Dye-doped silica nanoparticles functionalized with octadecyl and carboxylate groups showed minimal nonspecific binding. Using these surface-modification schemes, fluorescent dye-doped silica nanoparticles can be more readily conjugated with biomolecules and used as highly fluorescent, sensitive, and reproducible labels in bioanalytical applications.

Coated Materials, Biocompatible↗

[Effect of acid-base two steps surface modification on the adsorption of Cr(VI) onto activated carbon].

Effect of HNO3-NaOH two steps surface modification on the adsorption of Cr(VI) from aqueous solution onto activated carbon was evaluated. Activated carbon was oxidized in HNO3 aqueous solution at first (AC1), then treated in the mixture of NaOH and NaCl solution (AC2). Batch equilibrium and continuous adsorption experiments were conducted to determine the adsorption characteristics. Boehm titration method, element analysis were used to characterize the surface properties. N2/77 K adsorption isotherm method was used to characterize the pore structure. The results reveal that adsorption capacity and adsorption rate increase significantly, which in the following order: AC2>AC1>AC0. Surface modification caused BET surface area decreased and the total number of surface oxygen acid groups increased. First oxidation modification in HNO3 solution produced positive acid groups on the surface of activated carbon. Subsequent 2nd modification replaced H+ of carbon surface groups by Na+, the acidity of AC2 was decreased. The main cause of higher Cr(VI) adsorption capacity and rate for AC2 was the more oxygen surface acid groups, and suitable solution pH provide by surface groups.

Adsorption↗

Improved biocompatibility of intraocular lenses by heparin surface modification: a 12-month implantation study in monkeys.

To evaluate the long-term biocompatibility and potential side effects of heparin surface modification of a poly(methyl methacrylate) intraocular lens (IOL), a heparin surface modified IOL was implanted in the left posterior chamber of 24 cynomolgus monkeys and a reference IOL (without surface modification) was implanted in the right eye in 12 of these animals. Twelve eyes were not operated on. Eleven eyes in seven monkeys were lens extracted as a control of the surgical method. Slitlamp examinations and intraocular pressure recordings were made one day, one and two weeks, and 1, 2, 2 1/2, 3 1/2, 6, 8, 10, and 12 months after the operation. Eleven monkeys were sacrificed after 3 1/2 months and the remaining animals after 12 months for morphological examination of the eyes. Slitlamp and morphological examinations showed that cell deposits, pigmentation, and posterior synechias were significantly less in eyes with heparin surface modified IOLs than in eyes with reference IOLs throughout the 12-month observation period. The intraocular pressure was equally reduced in eyes with heparin surface modified IOLs and reference IOLs for about one month, after which it returned to normal. No side effects following the implantation of heparin surface modified IOLs were observed. We concluded that heparin surface modification of IOLs is efficient for long-term reduction of cell deposits and posterior synechias after implantation in monkey eyes and may also be effective in lowering the degree of side effects to IOL implantation in humans.

Animals↗

Surface modification using a commercial triple quadrupole mass spectrometer.

We report instrumental modifications to a commercial mass spectrometer that allow surface modification experiments to be performed using low-energy (electronvolt range) mass-selected ion beams. The design of the detector housing allows placement of the surface on the ion optical axis and some distance beyond the off-axis detector. Manipulation of the potentials applied to the final lens, detector housing, conversion dynode, and electron multiplier allow the ions to pass through the detector housing and impinge upon the surface without loss of the normal mode of detector operation. Ex situ analysis of the modified surface is performed using a home-built multisector mass spectrometer. The ability to modify organic thin films is demonstrated by a number of soft landing and surface modification experiments including (i) soft landing of (CH3)2SiNCS+ ions formed from trimethylsilyl isothiocyanate upon a fluorinated self-assembled monolayer (F-SAM) surface, (ii) soft landing and dissociative soft landing of the pseudomolecular cation of triphenylpyrylium tetrafluoroborate, viz. the triphenylpyrylium cation, upon an F-SAM surface, (iii) dissociative soft landing of 35ClCH2(CH3)2SiOSi(CH3)2+ formed from 1,3-bis(chloromethyl)disiloxane upon an F-SAM surface, (iv) surface passivation by reaction of the trimethylsilyl cation, Si(CH3)3+, with a hydroxyl-terminated self-assembled monolayer (OH-SAM), and (v) transhalogenation by reaction of CCl3+ (m/z 119) with an F-SAM surface.

Journal Article↗

Surface modification of poly(lactide-co-glycolide) nanospheres by biodegradable poly(lactide)-poly(ethylene glycol) copolymers.

The modification of surface properties of biodegradable poly(lactide-co- glycolide) (PLGA) and model polystyrene nanospheres by poly(lactide)-poly(ethylene glycol) (PLA:PEG) copolymers has been assessed using a range of in vitro characterization methods followed by in vivo studies of the nanospheres biodistribution after intravenous injection into rats. Coating polymers with PLA:PEG ratio of 2:5 and 3:4 (PEG chains of 5000 and 2000 Da. respectively) were studied. The results reveal the formation of a PLA:PEG coating layer on the particle surface resulting in an increase in the surface hydrophilicity and decrease in the surface charge of the nanospheres. The effects of addition of electrolyte and changes in pH on stability of the nanosphere dispersions confirm that uncoated particles are electrostatically stabilized, while in the presence of the copolymers, steric repulsions are responsible for the stability. The PLA:PEG coating also prevented albumin adsorption onto the colloid surface. The evidence that this effect was observed for the PLA:PEG 3:4 coated nanospheres may indicate that a poly(ethylene glycol) chain of 2000 Da can provide an effective repulsive barrier to albumin adsorption. The in vivo results reveal that coating of PLGA nanospheres with PLA:PEG copolymers can alter the biodistribution in comparison to uncoated PLGA nanospheres. Coating of the model polystyrene nanospheres with PLA:PEG copolymers resulted in an initial high circulation level, but after 3 hours the organ deposition data showed values similar to uncoated polystyrene spheres. The difference in the biological behaviour of coated PLGA and polystyrene nanospheres may suggest a different stability of the adsorbed layers on these two systems.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

The threshold effects of Nd and Ho: YAG laser-induced surface modification on demineralization of dentin surfaces.

Laser irradiation alters the structure of dentin and produces surface layers that give the appearance of being more enamel-like. The laser-modified surface may be more resistant to demineralization; hence, many investigators are proposing continued development of the laser as a possible preventive treatment for caries. The purpose of this study was to explore the morphological changes that occur in dentin when treated at threshold illuminance with two clinically interesting laser wavelengths, and to evaluate the effectiveness of the laser-treated surface at resisting demineralization in an acid-gel solution. The Nd: YAG laser (wavelength 1060 nm) produced significant recrystallization and grain growth of the apatite, without the formation of second phases such as beta-tricalcium phosphate. This recrystallized surface layer showed resistance to demineralization; however, the layer did not provide protection of the underlying dentin from demineralization because of cracks and macroscopic voids that allowed for penetration of the demineralizing gel. The Ho: YAG laser-treated surface (wavelength 2100 nm) did not show significant evidence of recrystallization and grain growth, and only a trace amount of an acid-resistant layer was observed with demineralization. It is speculated that the Ho:YAG laser is coupling with absorbed water, and that the heat transfer from the water to the mineral phase is inefficient. For the purposes of creating a demineralization-resistant layer, threshold illuminance with both Nd: YAG and Ho: YAG was ineffective.

Absorption↗

Effects of surface modification of materials on human neutrophil activation.

The properties of a polymer surface affect the cellular functions and morphology of cells in contact with the polymer. In this paper, we will demonstrate the effects of surface modification of materials on various neutrophil markers of activation. The sulfonation of a polystyrene surface caused increases in its negative charge and hydrophilicity. The sulfonation did not affect the number of adhered neutrophils, but the shape of the neutrophils adhered on the material was different; a round shape on highly sulfonated polystyrene and a spread shape on weakly sulfonated or non-sulfonated polystyrene. Expression of the adhesion molecule, CD11b, on neutrophils was also affected by the properties of the polymer surface. CD11b was expressed in neutrophils adhered on polystyrene and the expression decreased with increasing sulfonation of the surface. The expression of CD11b on the neutrophils on highly sulfonated polystyrene was the same as that on non-adhered neutrophils. In contrast, the expression of CD11a was not affected by the properties of the material surface. The F-actin content of activated neutrophils and the production of active oxygen groups detected by means of luminol-dependent chemiluminescence were also dependent on the sulfo-group content of the material surface. Finally, the translocation of protein kinase C (PKC) was determined in neutrophils adhered to these materials. Compared to non-adhered cells, the ratio of membrane bound to cytosolic PKC increased in adhered cells, but the increase was suppressed by sulfonation of the material surface. These data suggest that activation of neutrophils on polystyrene is suppressed by surface modification with increasing negative charge and/or hydrophilicity.

Actins↗

A surface modification strategy on silicon nitride for developing biosensors.

A surface modification strategy for the use of giant magnetoresistive materials in the detection of protein-protein interactions is developed. This modification strategy is based on silanization of semiconductive materials. A native silicon nitride surface was treated with concentrated hydrofluoric acid to improve surface homogeneity. Nano-strip was used to oxidize silicon nitride to form a hydrophilic layer. Aminopropyltriethoxysilane was subsequently used to functionalize the treated surfaces to form amine groups, which were further activated with glutaraldehyde to introduce a layer of aldehyde groups. The effectiveness of this modification strategy was validated by chemiluminescence immunoassays of purified 6x His-HrpW of Pseudomonas syringae pv. tomato DC3000 and human transferrin. Signals with intensities related to concentrations of these two immobilized model proteins were observed. The modified surface was also validated by a more complex system: intercellular proteins secreted by DC3000. HrpW in these protein mixtures was successfully recognized by anti-HrpW antibodies when mixed proteins were immobilized onto activated surfaces. This surface modification strategy provides a platform onto which proteins can be directly immobilized for biosensor and protein array applications.

Biosensing Techniques↗

Surface modification for improved blood compatibility.

Several surface modification techniques are currently being used to improve the biocompatibility of blood-contacting devices. These include the immobilization of bioactive materials to prevent thrombus generation and platelet activation, the incorporation of hydrophilic grafts onto practical hydrophobic surfaces (polyurethanes) to reduce protein adsorption, and the concept of microdomain-phase separated surfaces to regulate cellular and protein adhesion.

Animals↗

Surface modification of low-density polyethylene by inductively coupled argon plasma.

The surface chemistry and nanotopography of low-density polyethylene (LDPE) were modified by downstream, inductively coupled, radio frequency (rf) Ar plasma without inducing surface damage. The extent of surface modification was controlled by the applied ion energy fluence, determined from the plasma ion density measured with a Langmuir probe. The treated LDPE surfaces were characterized by atomic force microscope (AFM) imaging, contact angle measurements, and X-ray photoelectron spectroscopy (XPS). Analysis of AFM surface images confirmed that topography changes occurred at the nanoscale and that surface damage was insignificant. Contact angle measurements demonstrated an enhancement of the surface hydrophilicity with the increase of the plasma power. XPS results showed surface chemistry changes involving the development of different carbon-oxygen functionalities that increased the surface hydrophilicity. Physical and chemical surface modification was achieved under conditions conducive to high-density inductively coupled rf plasma.

Algorithms↗