Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “atomic force microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Characterisation of heterogeneous arabinoxylans by direct imaging of individual molecules by atomic force microscopy.

Atomic force microscopy has been used to characterise populations of extracted water-soluble wheat endosperm arabinoxylans. The adsorbed molecules are extended structures with an estimated Kuhn statistical segment length of 128 nm, suggesting that they adopt an ordered helical structure. However, estimates of the molecular weight distribution, coupled with size exclusion data, suggest that, in solution, the polysaccharides behave as semi-flexible coils, with a Kuhn length of 16 nm. These data imply that adsorption of the arabinoxylan structures onto mica promotes formation of the helical structure. Adoption of this ordered structure is fortunate because it has permitted characterisation of branching observed in a small proportion (approximately 15%) of the population of otherwise linear molecules. The degree of branching has been found to increase with the contour length of the molecules. Degradation of the polysaccharides with xylanase has been used to confirm that both the backbone and branches are based on beta-(1-->4) linked D-xylopyranosyl residues.

Adsorption↗

Collision events between RNA polymerases in convergent transcription studied by atomic force microscopy.

Atomic force microscopy (AFM) has been used to image, at single molecule resolution, transcription events by Escherichia coli RNA polymerase (RNAP) on a linear DNA template with two convergently aligned lambda(pr) promoters. For the first time experimentally, the outcome of collision events during convergent transcription by two identical RNAP has been studied. Measurement of the positions of the RNAP on the DNA, allows distinction of open promoter complexes (OPCs) and elongating complexes (EC) and collided complexes (CC). This discontinuous time-course enables subsequent analysis of collision events where both RNAP remain bound on the DNA. After collision, the elongating RNAP has caused the other (usually stalled) RNAP to back-track along the template. The final positions of the two RNAP indicate that these are collisions between an EC and a stalled EC (SEC) or OPC (previously referred to as sitting-ducks). Interestingly, the distances between the two RNAP show that they are not always at closest approach after 'collision' has caused their arrest.

DNA↗

Localization of amiloride-sensitive sodium channels in A6 cells by atomic force microscopy.

Atomic force microscopy (AFM) was used for high-resolution imaging of the apical distribution of epithelial Na+ channels in A6 renal epithelial cells. A6 cells grown on coverslips were labeled with antibodies generated against an amiloride-sensitive epithelial Na+ channel complex purified from bovine renal medulla that had been conjugated to 8-nm colloidal gold particles before preparation for AFM. AFM revealed that there was a marked increase in the height of the microvilli in cells labeled with the anti-epithelial Na+ channel antibodies compared with unlabeled cells or cells labeled with rabbit nonimmune immunoglobulin G conjugated to colloidal gold particles. We interpret this apparent increase in microvillar height to be due to anti-epithelial Na+ channel antibody binding to the apical microvilli. These data demonstrate that epithelial Na+ channels are restricted to the apical microvilli in Na+-transporting renal epithelial cells. Furthermore, they demonstrate the applicability of using AFM for high-resolution imaging of the cell surface distribution of epithelial ion channels.

Amiloride↗

Analysis of the intrinsic bend in the M13 origin of replication by atomic force microscopy.

Atomic force microscopy (AFM) has been used to image a 471-bp bent DNA restriction fragment derived from the M13 origin of replication in plasmid LITMUS 28, and a 476-bp normal, unbent fragment from plasmid pUC19. The most probable angle of curvature of the 471-bp DNA fragment is 40-50 degrees, in reasonably good agreement with the bend angle determined by transient electric birefringence, 38 degrees +/- 7 degrees. The normal 476-bp DNA fragment exhibited a Gaussian distribution of bend angles centered at 0 degrees, indicating that this fragment does not contain an intrinsic bend. The persistence length, P, was estimated to be 60 +/- 8 and 62 +/- 8 nm for the 471- and 476-bp fragments, respectively, from the observed mean-square end-to-end distances in the AFM images. Since the P-values of the normal and bent fragments are close to each other, the overall flexibility of DNA fragments of this size is only marginally affected by the presence of a stable bend. The close agreement of AFM and transient electric birefringence results validates the suitability of both methods for characterizing DNA bending and flexibility.

Crystallography↗

Preliminary analysis of polyhydroxyalkanoate inclusions using atomic force microscopy.

Atomic force microscopy analysis of polyhydroxyalkanoate (PHA) inclusions isolated from sonicated Ralstonia eutropha cells revealed that they exhibit two types of surface structure and shape; rough and ovoid, or smooth and spherical. Smooth inclusions possessed linear surface structures that were in parallel arrays with 7-nm spacing. Occasionally, cracks or fissures could be seen on the surface of the rough inclusions, which allowed a measurement of approximately 4 nm for the thickness of the boundary layer. When the rough inclusions were imaged at higher resolution, globular structures, 35 nm in diameter, having a central pore could be seen. These globular structures were connected by a network of 4-nm-wide linear structures. When the inclusions were treated with sodium lauryl sulfate, the boundary layer of the inclusion deteriorated in a manner that would be consistent with a lipid envelope. When the boundary layer was largely gone, 35-nm globular disks could be imaged laying on the surface of the filter beside the inclusions. These data have facilitated the development of a preliminary model for PHA inclusion structure that is more advanced than previous models.

Cupriavidus necator↗

Structural perturbations in DNA caused by bis-intercalation of ditercalinium visualised by atomic force microscopy.

Atomic force microscopy (AFM) has been used to examine perturbations in the tertiary structure of DNA induced by the binding of ditercalinium, a DNA bis-intercalator with strong anti-tumour properties. We report AFM images of plasmid DNA of both circular and linearised forms showing a difference in the formation of supercoils and plectonemic coils caused at least in part by alterations in the superhelical stress upon bis-intercalation. A further investigation of the effects of drug binding performed with 292 bp mixed-sequence DNA fragments, and using increment in contour length as a reliable measure of intercalation, revealed saturation occurring at a point where sufficient drug was present to interact with every other available binding site. Moment analysis based on the distribution of angles between segments along single DNA molecules showed that at this level of bis-intercalation, the apparent persistence length of the molecules was 91.7 +/- 5.7 nm, approximately twice as long as that of naked DNA. We conclude that images of single molecules generated using AFM provide a valuable supplement to solution-based techniques for evaluation of physical properties of biological macromolecules.

Carbazoles↗

Morphology and transverse stiffness of Drosophila myofibrils measured by atomic force microscopy.

Atomic force microscopy was used to investigate the surface morphology and transverse stiffness of myofibrils from Drosophila indirect flight muscle exposed to different physiologic solutions. I- and A-bands were clearly observed, and thick filaments were resolved along the periphery of the myofibril. Interfilament spacings correlated well with estimates from previous x-ray diffraction studies. Transverse stiffness was measured by using a blunt tip to indent a small section of the myofibrillar surface in the region of myofilament overlap. At 10 nm indention, the effective transverse stiffness (K( perpendicular)) of myofibrils in rigor solution (ATP-free, pCa 4.5) was 10.3 +/- 5.0 pN nm(-1) (mean +/- SEM, n = 8); in activating solution (pCa 4.5), 5.9 +/- 3.1 pN nm(-1); and in relaxing solution (pCa 8), 4.4 +/- 2.0 pN nm(-1). The apparent transverse Young's modulus (E( perpendicular)) was 94 +/- 41 kPa in the rigor state and 40 +/- 17 kPa in the relaxed state. The value of E( perpendicular) for calcium-activated myofibrils (55 +/- 29 kPa) was approximately a tenth that of Young's modulus in the longitudinal direction, a difference that at least partly reflects the transverse flexibility of the myosin molecule.

Animals↗

Size and shape of mineralites in young bovine bone measured by atomic force microscopy.

Atomic force microscopy (AFM) was used to obtain three-dimensional images of isolated mineralites extracted from young postnatal bovine bone. The mean mineralite size is 9 nm x 6 nm x 2.0 nm, significantly shorter and thicker than the mineralites of mature bovine bone measured by the same technique. Mineralites of the young postnatal bone can be accommodated within the hole zone regions of a quasi-hexagonally packed collagen fibril in the fashion described by Hodge [9] in which laterally adjacent hole zone regions form continuous "channels" across the diameter of a fibril for a distance of at least 10 nm. Deposition of mineralites of the size noted above in this void volume of the fibrils would result in little or no distortion of the collagen molecules or supramolecular structure of the collagen fibril. The new AFM data supporting this claim is consistent with findings obtained by electron microscopy and low-angle x-ray and neutron diffraction that mineralites formed within collagen fibrils during initial stages of calcification occur within the hole zone region. However, the deposition of additional mineralites in the intermolecular spaces between collagen molecules in the overlap region of the fibrils would significantly distort the fibrils since the space available between adjacent molecules is considerably less than even the smallest dimension of the mineralites.

Animals↗

Morphology and current-voltage characteristics of nanostructured pentacene thin films probed by atomic force microscopy.

Atomic force microscopy was used to study the growth modes (on SiO2, MoS2, and Au substrates) and the current-voltage (I-V) characteristics of organic semiconductor pentacene. Pentacene films grow on SiO2 substrate in a layer-by-layer manner with full coverage at an average thickness of 20 A and have the highest degree of molecular ordering with large dendritic grains among the pentacene films deposited on the three different substrates. Films grown on MoS2 substrate reveal two different growth modes, snowflake-like growth and granular growth, both of which seem to compete with each other. On the other hand, films deposited on Au substrate show granular structure for thinner coverages (no crystal structure) and dendritic growth for higher coverages (crystal structure). I-V measurements were performed with a platinum tip on a pentacene film deposited on a Au substrate. The I-V curves on pentacene film reveal symmetric tunneling type character. The field dependence of the current indicates that the main transport mechanism at high field intensities is hopping (Poole-Frenkel effect). From these measurements, we have estimated a field lowering coefficient of 9.77 x 10(-6) V-1/2 m1/2 and an ideality factor of 18 for pentacene.

Crystallization↗

Spatial distribution of radiation-induced double-strand breaks in plasmid DNA as resolved by atomic force microscopy.

Atomic force microscopy (AFM) has been used to directly visualize, size and compare the DNA fragments resulting from exposure to low- and high-LET radiation. Double-stranded pUC-19 plasmid ("naked") DNA samples were irradiated by electron-beam or reactor neutron fluxes with doses ranging from 0.9 to 10 kGy. AFM scanning in the tapping mode was used to image and measure the DNA fragment lengths (ranging from a few bp up to 2864 bp long). Double-strand break (DSB) distributions resulting from high-LET neutron and lower-LET electron irradiation revealed a distinct difference between the effects of these two types of radiation: Low-LET radiation-induced DSBs are distributed more uniformly along the DNA, whereas a much larger proportion of neutron-induced DSBs are distributed locally and densely. Furthermore, comparisons with predictions of a random DSB model of radiation damage show that neutron-induced DSBs deviate more from the model than do electron-induced DSBs. In summary, our high-resolution AFM measurements of radiation-induced DNA fragment-length distributions reveal an increased number of very short fragments and hence clustering of DSBs induced by the high-LET neutron radiation compared with low-LET electron radiation and a random DSB model prediction.

DNA↗

Measuring elasticity of biological materials by atomic force microscopy.

Atomic force microscopy (AFM) has proved its value not only for resolving the topographical structure of biological samples, but also for probing inherent properties of biological structures, like local interaction forces, mechanical properties or dynamics in a natural (physiological) environment. This minireview focuses on the acquisition of elasticity data of biomaterials by AFM. A possible theoretical model is presented, followed by a practical 'how to do it with AFM', and, finally, a brief overview of publications in this field is given.

Animals↗

Individual cartilage aggrecan macromolecules and their constituent glycosaminoglycans visualized via atomic force microscopy.

Atomic force microscopy was used in ambient conditions to directly image dense and sparse monolayers of bovine fetal epiphyseal and mature nasal cartilage aggrecan macromolecules adsorbed on mica substrates. Distinct resolution of the non-glycosylated N-terminal region from the glycosaminoglycan (GAG) brush of individual aggrecan monomers was achieved, as well as nanometer-scale resolution of individual GAG chain conformation and spacing. Fetal aggrecan core protein trace length (398+/-57 nm) and end-to-end length (257+/-87 nm) were both larger than that of mature aggrecan (352+/-88 and 226+/-81 nm, respectively). Similarly, fetal aggrecan GAG chain trace length (41+/-7 nm) and end-to-end (32+/-8 nm) length were both larger than that of mature aggrecan GAG (32+/-5 and 26+/-7 nm, respectively). GAG-GAG spacing along the core protein was significantly smaller in fetal compared to mature aggrecan (3.2+/-0.8 and 4.4+/-1.2nm, respectively). Together, these differences between the two aggrecan types were likely responsible for the greater persistence length of the fetal aggrecan (110 nm) compared to mature aggrecan (82 nm) calculated using the worm-like chain model. Measured dimensions and polymer statistical analyses were used in conjunction with the results of Western analyses, chromatographic, and carbohydrate electrophoresis measurements to better understand the dependence of aggrecan structure and properties on its constituent GAG chains.

Aggrecans↗

Solid-state DNA sizing by atomic force microscopy.

Atomic force microscopy (AFM) allows rapid, accurate, and reproducible visualization of DNA adsorbed onto solid supports. The images reflect the lengths of the DNA molecules in the sample. Here we propose a solid-state DNA sizing (SSDS) method based on AFM as an analytical method for high-throughput applications such as finger-printing, restriction mapping, +/- screening, and genotyping. For this process, the sample is first deposited onto a solid support by adsorption from solution. It is then dried and imaged under ambient conditions by AFM. The resulting images are subjected to automated determination of the lengths of the DNA molecules on the surface. The result is a histogram of sizes that is similar to densitometric scans of DNA samples separated on gels. A direct comparison of SSDS with agarose gel electrophoresis for +/- screening shows that it produces equivalent results. Advantages of SSDS include reduced sample size (i.e., lower reagent costs), rapid analysis of single samples, and potential for full automation using available technology. The high sensitivity of the method also allows the number of polymerase chain reaction cycles to be reduced to 15 or less. Because the high signal-to-noise ratio of the AFM allows for direct visualization of DNA-binding proteins, different DNA conformations, restriction enzymes, and other DNA modifications, there is potential for dramatically improving the information content in this type of analysis.

Adsorption↗

The EcoRI-DNA complex as a model for investigating protein-DNA interactions by atomic force microscopy.

Atomic force microscopy (AFM) is a technique widely used to image protein-DNA complexes, and its application has now been extended to the measurements of protein-DNA binding constants and specificities. However, the spreading of the protein-DNA complexes on a flat substrate, generally mica, is required prior to AFM imaging. The influence of the surface on protein-DNA interactions is therefore an issue which needs to be addressed. For that purpose, the extensively studied EcoRI-DNA complex was investigated with the aim of providing quantitative information about the surface influence. The equilibrium binding constant of the complex was determined by AFM at both low and high ionic strengths and compared to electrophoretic mobility shift assay measurements (EMSA). In addition, the effect of the DNA length on dissociation of the protein from its specific site was analyzed. It turned out that the AFM measurements are similar to those obtained by EMSA at high ionic strengths. We then advance the idea that this effect is due to the high counterion concentration near the highly negatively charged mica surface. In addition, a dissociation of the complexes once they are adsorbed onto the surface was observed, which is weakly dependent on the ionic strength contrary to what occurs in solution. Finally, a two-step mechanism, which describes the adsorption of the EcoRI-DNA complexes on the surface, is proposed. This model could also be extended to other protein-DNA complexes.

DNA Primers↗

Nanoscale compression of polymer microspheres by atomic force microscopy.

Atomic force microscopy (AFM) was employed to probe the mechanical properties of surface-charged polystyrene microspheres with 1-12 mol% of vinylbenzyl(trimethyl)ammonium chloride (VBTA) units. On the basis of Hertz's theory of contact mechanics, compressive moduli between 1 and 2 GPa were measured by the analysis of force-displacement curves captured on the particles via the force-volume technique. The deformation of the top of the polystyrene particles by the AFM tip was used to calculate the surface modulus. The compressive moduli are slightly less than the moduli of polystyrene bulk materials. The modulus of the polystyrene microspheres increases with an increase of the VBTA content.

Compressive Strength↗

Probing soft polymeric coatings of a capillary by atomic force microscopy.

Atomic force microscopy (AFM) has been used to probe the surface of a capillary after coating with "soft" polymers, notably polyacrylamides. The aim was the investigation of the efficiency of coverage of the silica surface, so as to reduce or eliminate the electroosmotic flow (EOF), particularly noxious in the separation of macromolecules. The quality of such coating is strongly dependent on two variables: temperature and pH. In the first case, progressively higher temperatures produce open silica patches, where no polymer seems to be bound. The transition from coated to largely uncoated surfaces occurs at 50 degrees C. Also the pH of the polymerizing solution strongly affects the coating efficiency. Since in all coating procedures the monomer solution is not buffered, addition of accelerator (TEMED, N,N,N'N'-tetramethylethylendiamine) induces polymer growth at pH 10-11. These pH values generate hydrolysis of the siloxane bridge anchoring the bifunctional agent (Bind Silane, onto which the polymer chain should grow) to the wall. Thus, coating and de-coating occur simultaneously. Low temperatures during polymer growth (typically 10 degrees C) and buffered solutions (pH 7, titrated after TEMED addition) ensure a most efficient and thorough coating, with virtual elimination of EOF: well coated capillaries exhibit residual EOF values, at pH 10, of the order of 10(-7) cm2 V-1 s-1 vs. a standard value for uncoated capillaries of the order of 10(-4) cm2 V-1 s-1. The AFM data have been fully confirmed by direct measurement of EOF in coated and uncoated capillaries under an electric field.

Electrophoresis, Capillary↗

Large fluctuations in the disassembly rate of microtubules revealed by atomic force microscopy.

Atomic force microscopy (AFM) in situ has been used to observe the cold disassembly dynamics of microtubules at a previously unrealised spatial resolution. Microtubules either electrostatically or covalently bound to aminosilane surfaces disassembled at room temperature under buffer solutions with no free tubulin present. This process was followed by taking sequential tapping-mode AFM images and measuring the change in the microtubule end position as a function of time, with an spatial accuracy down to +/-20nm and a temporal accuracy of +/-1s. As well as giving average disassembly rates on the order of 1-10 tubulin monomers per second, large fluctuations in the disassembly rate were revealed, indicating that the process is far from smooth and linear under these experimental conditions. The surface bound rates measured here are comparable to the rates for GMPCPP-tubulin microtubules free in solution, suggesting that inhibition of tubulin curvature through steric hindrance controls the average, relatively low disassembly rate. The large fluctuations in this rate are thought to be due to multiple pathways in the kinetics of disassembly with differing rate constants and/or stalling due to defects in the microtubule lattice. Microtubules that were covalently bound to the surface left behind the protofilaments covalently cross-linked to the aminosilane via glutaraldehyde during the disassembly process. Further work is needed to quantitatively assess the effects of surface binding on protofibril disassembly rates, reveal any differences in disassembly rates between the plus and minus ends and to enable assembly as well as disassembly to be imaged in the microscope fluid cell in real-time.

Aluminum Silicates↗

Morphological analysis of glutaraldehyde-fixed vimentin intermediate filaments and assembly-intermediates by atomic force microscopy.

Atomic force microscopy (AFM) was used to study the morphology of vimentin intermediate filaments (IFs) and their assembly intermediates. At each time after initiation of IF assembly in vitro of recombinant mouse vimentin, the sample was fixed with 0.1% glutaraldehyde and then applied to AFM analysis. When mature vimentin IFs were imaged in air on mica, they appeared to have a width of approximately 28 nm, a height of approximately 4 nm and a length of several micrometers. Taking into account the probe tip's distortion effect, the exact width was evaluated to be approximately 25 nm, suggesting that the filaments flatten on the substrate rather than be cylindrical with a diameter of approximately 10 nm. Vimentin IFs in air clearly demonstrated approximately 21-nm repeating patterns along the filament axis. The three-dimensional profiles of vimentin IFs indicated that the characteristic patterns were presented by repeating segments with a convex surface. The repeating patterns close to 21 nm were also observed by AFM analysis in a physiological solution condition, suggesting that the segments along the filaments are an intrinsic substructure of vimentin IFs. In the course of IF assembly, assembly intermediates were analyzed in air. Many short filaments with a full-width and an apparent length of approximately 78 nm (evaluated length approximately 69 nm) were observed immediately after initiation of the assembly reaction. Interestingly, the short full-width filaments appeared to be composed of the four segments. Further incubation enabled the short full-width filaments to anneal longitudinally into longer filaments with a distinct elongation step of approximately 40 nm, which corresponds to the length of the two segments. To explain these observations, we propose a vimentin IF formation model in which vimentin dimers are supercoiling around the filament axis.

Animals↗