Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “STEEL”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Products of steel slags an opportunity to save natural resources.

In Germany, and in the most industrial countries, the use of blast furnace and steel slags as an aggregate for civil engineering, for metallurgical use and as fertiliser has a very long tradition. Since the introduction of the basic oxygen steel making furnace (BOF) process and the electric arc furnace (EAF) process the German steel industry started extensive research on the development of fields of application for BOF and EAF slags. These investigations have been mainly performed by Forschungsgemeinschaft Eisenhüttenschlacken e. V. (FEhS), the Research Association for blast furnace and steel slags. Today steel slags are well characterised and long-term experienced materials mainly used as aggregates for road construction (e.g. asphaltic or unbound layers), as armour-stones for hydraulic engineering constructions (e.g. stabilisation of shores), and as fertiliser for agriculture purposes. These multifarious fields of application could only be achieved because the steelworks influence the quality of slags by a careful selection of raw materials and a suitable process route. Furthermore, subsequent procedures like a treatment of the liquid slag, an appropriate heat treatment and a suitable processing have been developed to ensure that the quality of steel slags is always adequate for the end use. Depending on the respective field of application, the suitability of steel slags has to be proven by determining the technical properties, as well as the environmental compatibility. For this reason test methods have been developed to evaluate the technical properties especially the volume stability and the environmental behaviour. To evaluate the volume stability a suitable test (steam test) has been developed and the results from laboratory tests were compared with the behaviour of steel slags under practical conditions, e.g. in a road. To determine the environmental behaviour leaching tests have been developed. In the meanwhile most of these test methods are drafted or already accepted as a CEN standard and are used for a continuous quality control. Usually the suitability of steel slags is stated by fulfilling the requirements of national and/or international standards and regulations. Based on these standards and regulations in Germany in 1998 about 97% of the produced steel slags have been used as aggregates for road construction (e.g. as surface layer, road base and sub base for high trafficked roads), ways, earthworks, and armourstones for hydraulic structures. Consistent to the successful long-term experience not only products of steel slags but also products of blast furnace slags have been eliminated from the European Waste Catalogue and the European Shipment of Waste Regulation of the European Community, as well as from the lists of OECD for transfrontier movements by the decision of the OECD-Council from 21 September, 1995.

Conservation of Natural Resources↗

Effects of embedded tungsten-bismuth-tin shot and steel shot on mallards (Anas platyrhynchos).

We assessed the potential for embedded steel and tungsten-bismuth-tin (TBT) shot to adversely affect health of mallards (Anas platyrhynchos). Ducks were implanted with three number four steel (n = 19) or TBT (n = 20) shot pellets in their pectoral muscles. None of seven hematology parameters measured differed in response to treatment (P > or = 0.17). At necropsy 1, 2, 4, and 8 wk posttreatment, we observed only localized tissue reactions to embedded steel or TBT shot. Reactions differed grossly: after wk 1, embedded steel shot were enveloped in 0.5 to 2 mm grayish capsules, whereas TBT shot were surrounded by thinner (< 0.5 mm), translucent capsules. Corrosion of steel shot was apparent. Microscopic lesions associated with steel shot were characterized by moderate to severe histiocytic and lymphocytic inflammation and considerable particle deposition, whereas histiocytic inflammation was mild and particle deposition minimal in TBT lesions. Overall scores of inflammation at steel shot implant sites were greater (P < or = 0.043) than at TBT sites during wk 1 and 8. Inflammation at steel implant sites was relatively consistent over the 8-wk period, but decreased (P = 0.0017) at TBT sites by wk 8. Weights of steel shot recovered from muscle tissue declined logarithmically (R2 = 0.978, P = 0.0014) over 8 wk, but TBT shot weights remained unchanged (P = 0.255). Embedded TBT shot, as compared to steel, resisted corrosion and induced comparatively mild inflammatory responses in mallard muscle tissue. However, inflammatory reactions to both embedded steel and TBT shot were localized and had no detectable systemic effects on mallard health under experimental conditions.

Animals↗

Attachment of Shiga toxigenic Escherichia coli to stainless steel.

Shiga toxigenic Escherichia coli (STEC) are important foodborne pathogens causing gastrointestinal disease worldwide. Bacterial attachment to food surfaces, such as stainless steel may lead to cross contamination of foods and subsequent foodborne disease. A variety of STEC isolates, including E. coli O157:H7/H- strains, were grown in planktonic (broth) and sessile (agar) culture, following which initial attachment to stainless steel was determined using epifluorescence microscopy. Experiments were performed to determine whether the number of bacteria attached to stainless steel differed between STEC strains and between the two modes of growth. No relationship was found between STEC strains and the number of bacteria attached to stainless steel. Five STEC strains, including one non-toxigenic O157 isolate, attached in significantly greater (p<0.05) numbers to stainless steel following growth in planktonic culture compared to sessile culture. In contrast, two clinical strains of O157:H7 attached in significantly greater (p<0.05) numbers following growth in sessile culture compared to planktonic culture. Thirteen out of twenty E. coli strains showed no significant difference (p>0.05) in attachment when grown in planktonic or sessile culture. The change of interfacial free energy between the bacterial strains and stainless steel was calculated and the influence of free energy in attachment was determined. Although a significant variation (p<0.05) in free energy values was found between STEC strains, no correlation was found between free energy values and bacterial counts on stainless steel. In addition, no correlation was also found between bacterial hydrophobicity and surface charge values or production of surface structures (type I fimbriae or flagella) (previously determined) with the number of bacteria attached to stainless steel. The results of this study suggest that different growth conditions (planktonic and sessile) can influence the attachment of STEC to stainless steel. Factors other than bacterial physicochemical properties and these surface structures may also influence STEC attachment to stainless steel.

Bacterial Adhesion↗

Effectiveness of transfixation and length of instrumentation on titanium and stainless steel transpedicular spine implants.

This study compares the effectiveness of transfixation on the stiffness of two pedicle screw-rod constructs of different manufacture, implant design, and alloy, applied in one-and two-level instability. Four screws composed of either stainless steel or Titanium were assembled in pairs to two polymethylmethacrylate blocks to resemble one-and two-level corpectomy models and the construct underwent nondestructive torsional, extension, and flexion loading. In every loading test, each construct was tested using stainless steel or titanium rods of 4.9-mm diameter in two different lengths (short, 10 cm; long, 15 cm), not augmented or augmented with different transfixation devices or a pair of devices. The authors compared the stiffness of stainless steel and titanium constructs without cross-link with the stiffness of that reinforced with single or double Texas Scottish Rite Hospital (TSRH) cross-link, closed new-type cross-link (closed NTC), or open new-type cross-link (open NTC). The results showed that augmentation or no augmentation of short rods conferred significantly more stiffness than that of long rods of the same material in all three loading modes. The closed NTC provided the greatest increase of torsional, extension, and flexion stiffness, and single TSRH provided the least amount of stiffness. Torsional stiffness of short stainless steel rods augmented or not augmented was significantly greater than that of their titanium counterparts. Torsional stiffness of long titanium rods was always greater than that of their stainless steel counterparts. Extension stiffness of short nonaugmented titanium rods was superior to that of long titanium rods, whereas extension stiffness of nonaugmented short and long stainless steel rods was similar. Nonaugmented short titanium rods showed greater flexion stiffness than that of long titanium rods. Long stainless steel rods displayed significantly greater flexion stiffness than did their titanium counterparts. This nondestructive study showed that cross-links increase the torsional stiffness significantly but less so the flexion and extension stiffness of both titanium and stainless steel posterior transpedicular constructs. This increase was proportional to the cross-sectional diameter of the cross-link. Titanium constructs showed more torsional stiffness when used in two-level instability and steel showed more torsional stiffness in one-level instability, particularly when they are reinforced. Stainless steel constructs showed greater flexion stiffness when they were used in two-level and titanium showed greater flexion stiffness in one-level instability, particularly when they were reinforced with stiff cross-links. The effect of transfixation on extension forces was obvious when thick cross-links were used.

Alloys↗

Biomechanical assessment of titanium and stainless steel posterior spinal constructs: effects of absolute/relative loading and frequency on fatigue life and determination of failure modes.

The goal of this study was to examine the effects of absolute/relative loads and frequency on the fatigue life of titanium and stainless steel posterior spinal constructs, and to determine the failure fracture modes. The stainless steel constructs had higher stiffness and yield strength than the titanium constructs, but the ultimate static strength was almost equal for both types of constructs. Titanium constructs, however, exhibited higher variability than the stainless steel constructs. In fatigue tests, the stainless steel constructs were significantly affected by the external load and were frequency independent. It appears from fatigue curves that 500 N can be approximated as the endurance limit for the stainless steel constructs. Titanium constructs were load-frequency dependent, and their endurance limit was somewhere between the 500 and 750 N load levels. There were no differences in performance between the stainless steel and titanium constructs at 16 Hz. At 4 Hz, titanium constructs performed as well or better than stainless steel constructs. Also, the titanium constructs resulted in better performance than the stainless steel constructs in the elastic region, and with smaller differences in the plastic region. Most of the failure modes for stainless steel constructs were in screw bending at 16 Hz with a smaller percentage of rod fractures at high loads, with a higher percentage of rod fractures observed for the stainless steel constructs at 4 Hz. Most of the failure modes for titanium constructs occurred in screw bending or fracture.

Biomechanical Phenomena↗

Evaluation of a safety resheathable winged steel needle for prevention of percutaneous injuries associated with intravascular-access procedures among healthcare workers.

OBJECTIVE: To compare the percutaneous injury rate associated with a standard versus a safety resheathable winged steel (butterfly) needle. DESIGN: Before-after trial of winged steel needle injuries during a 33-month period (19-month baseline, 3-month training, and 11-month study intervention), followed by a 31-month poststudy period. SETTING: A 1,190-bed acute care referral hospital with inpatient and outpatient services in New York City. PARTICIPANTS: All healthcare workers performing intravascular-access procedures with winged steel needles. INTERVENTION: Safety resheathable winged steel needle. RESULTS: The injury rate associated with winged steel needles declined from 13.41 to 6.41 per 100,000 (relative risk [RR], 0.48; 95% confidence interval [CI95], 0.31 to 0.73) following implementation of the safety device. Injuries occurring during or after disposal were reduced most substantially (RR, 0.15; CI95, 0.06 to 0.43). Safety winged steel needle injuries occurred most often before activation of the safety mechanism was appropriate (39%); 32% were due to the user choosing not to activate the device, 21% occurred during activation, and 4% were due to improper activation. Preference for the safety winged steel needle over the standard device was 63%. The safety feature was activated in 83% of the samples examined during audits of disposal containers. Following completion of the study, the safety winged steel needle injury rate (7.29 per 100,000) did not differ significantly from the winged steel needle injury rate during the study period. CONCLUSION: Implementation of a safety resheathable winged steel needle substantially reduced injuries among healthcare workers performing vascular-access procedures. The residual risk of injury associated with this device can be reduced further with increased compliance with proper activation procedures.

Blood-Borne Pathogens↗

In vivo evaluation of a high-strength, high-ductility stainless steel for use in surgical implants.

A high-strength, high-ductility, austenitic stainless steel has been evaluated for use in surgical implants by performing in vivo tests in rats, rabbits, dogs, and rhesus monkeys. This stainless steel, a TRIP (Transformation Induced Plasticity) steel containing about 4% Mo, was compared with two alloys in current clinical use: Type 316L stainless steel and cast Vitallium. Compared with the other two alloys, cast Vitallium generally had higher resistance to corrosion and superior biocompatibility in all animals. The tests in rats and dogs indicated that the corrosion resistances of the TRIP steel and the Type 316L stainless steel were similar and that the tissue reactions caused by these alloys were also similar. However, in rhesus monkeys, the TRIP steel was shown to be susceptible to stress-corrosion cracking and much more susceptible to crevice corrosion than Type 316L stainless steel. Limited tests in rabbits supported the observation that the TRIP steel is susceptible to stress-corrosion cracking. These inconsistencies in the in vivo tests underline the need for a reevaluation of the popular test techniques and of the animals commonly chosen for assessing the suitability of candidate implant materials. The "worst case" results from the rhesus monkey tests were entirely consistent with previous results obtained from in vitro studies. However, further work must be performed before the behavior of metals in humans, rhesus monkeys, or any other animal, can be predicted with confidence from an in vitro test program.

Animals↗

Cytotoxicity study of plasma-sprayed hydroxyapatite coating on high nitrogen austenitic stainless steels.

Stainless steel has been frequently used for temporary implants but its use as permanent implants is restricted due to its low pitting corrosion resistance. Nitrogen additions to these steels improve both mechanical properties and corrosion resistance, particularly the pitting and crevice corrosion resistance. Many reports concerning allergic reactions caused by nickel led to the development of nickel free stainless steel; it has excellent mechanical properties and very high corrosion resistance. On the other hand, stainless steels are biologically tolerated and no chemical bonds are formed between the steel and the bone tissue. Hydroxyapatite coatings deposited on stainless steels improve osseointegration, due their capacity to form chemical bonds (bioactive fixation) with the bone tissue. In this work hydroxyapatite coatings were plasma-sprayed on three austenitic stainless steels: ASTM-F138, ASTM-F1586 and the nickel-free Böhler-P558. The coatings were analyzed by SEM and XDR. The cytotoxicity of the coatings/steels was studied using the neutral red uptake method by quantitative evaluation of cell viability. The three uncoated stainless steels and the hydroxyapatite coated Böhler-P558 did not have any toxic effect on the cell culture. The hydroxyapatite coated ASTM-F138 and ASTM-F1586 stainless steels presented cytotoxicity indexes (IC50%) lower than 50% and high nickel contents in the extracts.

Animals↗

Complications of intravenous therapy with steel needles and Teflon catheters. A comparative study.

Complications of intravenous therapy with steel needles and small-bore Teflon catheters were compared in a randomized study of 954 cannula insertions. Cannulas were inserted and cared for by an intravenous team following a standard protocol. There were no cases of cannula-related septicemia and only one case of local infection, a cellulitis in the group in which Teflon catheters were used. There was a low incidence of positive semiquantitative cannula cultures in both treatment groups (steel needles 1.5 percent, Teflon catheters 1.4 percent). The risk of phlebitis was significantly greater with Teflon catheters (18.8 percent with Teflon catheters, 8.8 percent with steel needles, adjusted odds ratio 1.87). Steel needles were significantly associated with infiltration (17.9 percent with Teflon catheters, 40.1 percent with steel needles, adjusted odds ratio 0.39). The over-all rate of complications was significantly greater for the group in which steel needles were used (53.8 versus 64.0 percent, adjusted odds ratio 0.72), principally due to the increased risk of infiltration with steel needles. Analysis of the per day risk of infiltration and phlebitis revealed that these relationships were present for each day the cannulas remained in place. We conclude (1) that steel needles and small-bore Teflon catheters can both be used with low risk of infection and (2) that Teflon catheters more frequently cause phlebitis, whereas steel needles infiltrate more readily.

Adolescent↗

Galvanic couples of 316L steel with Ti and ion plated Ti and TiN coatings in Ringer's solutions.

Steel 316L was coated with titanium or titanium nitride by ion plating. The tightness of the coatings was examined electro-chemically. The galvanic effects for the galvanic couples steel-titanium, steel-titanium-coated steel and steel-titanium nitride-coated steel were studied. It was found that both titanium and titanium nitride coatings were non-porous in Ringer's solution; titanium served as an anode in the couple steel-titanium; it was oxidized according to the logarithmic law. For the other two couples, the coatings were the cathodes. The rate of dissolution of steel in these couples, was however, smaller than expected, owing to a strong polarization of the coatings. The potential of the couple was similar to that of steel.

Corrosion↗

Cytokine production and protein adsorption in a stainless steel filter used for leukocyte reduction.

A new metallic filter made from a stainless steel fiber has been under development. To evaluate biocompatibility of this filter, the authors compared cytokine production with that of stainless steel fibers and polyester fibers by using a mononuclear cell culture. Furthermore, adsorbed proteins on each fiber were identified by using sodium-dodecyl sulfate (SDS)-polyacrlyamide gel electrophoresis (PAGE). The levels of tumor necrosis factor (TNF)-alpha in the cultured supernatant without fibers as the control, with polyester fibers, and with stainless steel fibers were 28.1 +/- 8.1, 39.3 +/- 2.6, and 29.1 +/- 6.7 pg/ml, respectively. The levels of interleukin (IL)-1 beta were 7.6 +/- 3.2, 8.9 +/- 1.5, and 8.9 +/- 2.1 pg/ml, respectively. The IL-4 levels were less than 0.25 pg/ml, and the interferon-tau levels were less than 7.8 pg/ml in all three conditions. The amount of adsorbed proteins was 3.39 +/- 0.27 microgram/cm2 for the polyester fibers and 2.72 +/- 0.23 microgram/ cm2 for the stainless steel fibers. The protein bands adsorbed to the polyester fibers by SDS-PAGE analysis were observed at approximately 180, 120, 90, 76, 67, 59, 56, and 28 kd molecular weight. In contrast, the protein bands adsorbed to the stainless steel fibers were observed at 90, 76, 67, 62, 56, 28, and 12 kd molecular weight. Thus, the proteins adsorbed to the stainless steel fibers differed from those on the polyester fibers. By western blot analysis, the amounts of albumin, IgG tau chain, and fibronectin adsorbed on the stainless steel fibers were smaller than those on the polyester fibers. The results of this study suggest that the stainless steel fibers do not stimulate monocytes, Th1, and Th2 cells. In addition, lesser adsorption of IgG tau chain and fibronectin may indicate that the stainless steel is a superior material for anti thrombogenicity compared to polyester.

Adsorption↗

Nickel release from stainless steels.

In 1994, a study of nickel release and allergic contact dermatitis from nickel-plated metals and stainless steels was published in this journal. It was shown that low-sulfur stainless steel grades like AISI 304, 316L or 430 (S < or = 0.007%) release less than 0.03 microgram/cm2/week of nickel in acid artificial sweat and elicit no reactions in patients already sensitized to nickel. In contrast, nickel-plated samples release around 100 micrograms/cm2/week of Ni and high-sulfur stainless steel (AISI 303-S approximately 0.3%) releases about 1.5 micrograms/cm2/week in this acid artificial sweat. Applied on patients sensitized to nickel, these metals elicit positive reactions in 96% and 14%, respectively, of the patients. The main conclusion was that low-sulfur stainless steels like AISI 304, 316L or 430, even when containing Ni, should not elicit nickel contact dermatitis, while metals having a mean corrosion resistance like a high-sulfur stainless steel (AISI 303) or nickel-plated steel should be avoided. The determining characteristic was in fact the corrosion resistance in chloride media, which, for stainless steels, is connected, among other factors, to the sulfur content. Thus, a question remained concerning the grades with an intermediate sulfur content, around 0.03%, which were not studied. They are the object of the study presented in this paper. 3 tests were performed: leaching experiments, dimethylglyoxime and HNO3 spot tests, and clinical patch tests; however, only stainless steels were tested: a low-sulfur AISI 304 and AISI 303 as references and 3 grades with a sulfur content around 0.03%: AISI 304L, AISI 304L added with Ca, AISI 304L+Cu. Leaching experiments showed that the 4 non-resulfurised grades released less than 0.5 microgram/cm2/week in acid sweat while the reulfurized AISI 303 released around or more than 0.5 microgram/cm2/week. This is explained by the poorer corrosion resistance of the resulfurized grade. Yet all these grades had the same reaction to the DMG test (negative result), which shows again its lack of sensitivity. In contrast, the HNO3 spot test distinguished AISI 303 from the non-resulfurized grades. Clinical patch tests again showed that some patients (4%) were intolerant to AISI 303, while none were intolerant to the other grades. Thus, this study confirms that non-resulfurized stainless steels (S < or = 0.03%) like Ni-containing 304 and 304L should not elicit Ni contact dermatitis, while the resulfurized grades (S > 0.1%) should be avoided.

Adolescent↗

Occupational asthma due to manual metal-arc welding of special stainless steels.

Occupational asthma (OA) can be induced by fumes of manual metal-arc welding on stainless steel. In recent years, the use of special stainless steels (SSS) with high chromium content has increased. This study presents two cases of OA caused by manual metal-arc welding on SSS. In both cases, the diagnosis of OA was based on respiratory symptoms, occupational exposure and positive findings in the specific challenge tests. In the first case, a 46-yr-old welder had experienced severe dyspnoea while welding SSS (SMO steel), but not in other situations. Challenge tests with both mild steel and stainless steel using a common electrode were negative. Welding SSS with a special electrode caused a delayed 37% drop in forced expiratory volume in one second (FEV1). In the second case, a 34-yr-old male had started to experience dyspnoea during the past few years, while welding especially SSS (Duplex steel). The workplace peak expiratory flow monitoring was suggestive of OA. Challenge tests with both mild steel and stainless steel using a common electrode did not cause bronchial obstruction. Welding SSS with a special electrode caused a delayed 31% drop in FEV1. In conclusion, exposure to manual metal-arc welding fumes of special stainless steel should be considered as a new cause of occupational asthma.

Adult↗

Influence of steel factor on hemoglobin synthesis in sickle cell disease.

A new hematopoietic growth factor (Steel factor) has been identified which stimulates erythroid proliferation both in vitro and in vivo. We evaluated the influence of recombinant Steel factor on hemoglobin synthesis in peripheral blood (PB) BFU-E-derived cells from normal donors by radioimmunoassay (RIA) and compared it with stimulation with GM-CSF and interleukin-3 (IL-3). Only Steel factor stimulated a significant increase in BFU-E-derived colony size and a significant increase in fetal hemoglobin (HbF) in BFU-E-derived erythroblasts from 0.49% +/- 0.27% to 6.33% +/- 1.11% in serum-deprived media and from 1.88% +/- 0.24% to 11.17% +/- 0.91% in serum. To determine whether this influence on hemoglobinization also occurred in sickle cell disease, we studied 13 patients with sickle cell disease. In serum-deprived conditions, there was a significant increase in the number and size of BFU-E-derived colonies with Steel factor that was dose-dependent. In addition, the proportion of HbF in progenitor-derived cells increased by 66% from 4.1% +/- 0.6% to 6.8% +/- 1.2% with Steel factor. In serum-containing conditions studied in 12 patients, the increase in percentage of HbF was even greater, from 10.7% +/- 0.9% in control cultures to 22.5% +/- 2.6% with Steel factor. These increases in percentage of HbF were significant and dose-dependent. An increase in percentage of HbF was observed in erythroblasts harvested on day 11, 14, and 18 of culture. A decrease in mean picograms of total Hb per cell after coculture with Steel factor was noted, suggesting that growth kinetics influenced complete hemoglobinization. In serum-deprived conditions, picograms of HbF per cell was not affected by Steel factor, and in serum-containing conditions that augment in vitro HbF production it was enhanced. Thus, Steel factor stimulated a significant increase in percentage of HbF in erythroid cells from normal donors and patients with SCA in vitro.

Anemia, Sickle Cell↗

Steel factor affects SCL expression during normal erythroid differentiation.

Steel factor is one of the growth factors that controls the proliferation and differentiation of hematopoietic cells and SCL, also known as Tcl-5 or Tal-1, is a transcription factor involved in erythropoiesis. In this report, we studied the role of SCL in the proliferation of human peripheral blood burst-forming unit-erythroid (BFU-E) and the effects of Steel factor on SCL expression in proliferating erythroid cells. BFU-E-derived colonies increase progressively in size, as determined by cell number, from day 7 to day 14 of culture, with the greatest increase in colony size (10-fold expansion) occurring between day 7 and day 10. SCL protein levels in BFU-E-derived cells were highest in day 7 cells and decreased progressively from day 7 to day 14 of culture, suggesting an association of SCL with erythroid proliferation. In contrast, SCL mRNA levels did not decrease significantly between day 7 and day 14 cells, suggesting that posttranscriptional mechanisms are largely responsible for the decrease in SCL protein observed. The role of SCL in Steel factor-induced erythroid proliferation was then examined. In BFU-E-derived colonies cultured with Steel factor, colony size was significantly increased compared to control. In day 7 and day 10 erythroid precursors cultured with Steel factor, SCL protein was increased significantly compared to control. The increase in SCL protein levels in early erythroid precursors stimulated with Steel factor suggests one mechanism through which Steel factor may enhance normal erythroid proliferation. SCL mRNA levels assessed by Northern blot in day 7 cells did not increase significantly in response to Steel factor stimulation, suggesting that posttranscriptional mechanisms may also be important in the increase in SCL protein observed in response to Steel.

Base Sequence↗

Impact of a nickel-reduced stainless steel implant on striated muscle microcirculation: a comparative in vivo study.

The impairment of skeletal muscle microcirculation by a biomaterial may have profound consequences. With moderately good physical and corrosion characteristics, implant-quality stainless steel is particularly popular in orthopedic surgery. However, due to the presence of a considerable amount of nickel in the alloy, concern has been voiced in respect to local tissue responses. More recently a stainless steel alloy with a significant reduction of nickel has become commercially available. We, therefore, studied in vivo nutritive perfusion and leukocytic response of striated muscle to this nickel-reduced alloy, and compared these results with those of the materials conventional stainless steel and titanium. Using the hamster dorsal skinfold chamber preparation and intravital microscopy, we could demonstrate that reduction of the nickel quantity in a stainless steel implant has a positive effect on local microvascular parameters. Although the implantation of a conventional stainless steel sample led to a distinct and persistent activation of leukocytes combined with disruption of the microvascular endothelial integrity, marked leukocyte extravasation, and considerable venular dilation, animals with a nickel-reduced stainless steel implant showed only a moderate increase of these parameters, with a clear tendency of recuperation. Titanium implants merely caused a transient increase of leukocyte-endothelial cell interaction within the first 120 min, and no significant change in macromolecular leakage, leukocyte extravasation, or venular diameter. Pending biomechanical and corrosion testing, nickel-reduced stainless steel may be a viable alternative to conventional implant-quality stainless steel for biomedical applications. Concerning tolerance by the local vascular system, titanium currently remains unsurpassed.

Animals↗

Properties of super stainless steels for orthodontic applications.

Orthodontic stainless-steel appliances are considered to be corrosion resistant, but localized corrosion can occur in the oral cavity. This study was undertaken to evaluate the properties of super stainless steels in orthodontic applications. Accordingly, the metallurgical properties, mechanical properties, corrosion resistance, amount of the released nickel, cytotoxicity, and characteristics of the passive film were investigated. Corrosion resistances of the specimens were high and in the following order: super austenitic stainless steel (SR-50A) > super ferritic stainless steel (SFSS) = super duplex stainless steel (SR-6DX) > 316L SS > super martensitic stainless steel (SR-3Mo) in artificial saliva, 37 degrees C. At 500 mV (SCE), current densities of SR-50A, SFSS, SR-6DX, 316L SS, and SR-3Mo were 5.96 microA/cm(2), 20.3 microA/cm(2), 31.9 microA/cm(2), 805 microA/cm(2), and 5.36 mA/cm(2), respectively. Open circuit potentials of SR-50A, 316L SS, SR-6DX, SR-3Mo, and SFSS were - 0.2, - 0.22, - 0.24, - 0.43, and - 0.46 V (SCE), respectively. SR-50A, SFSS, and SR-6DX released below 3 ng/ml nickel for 8 weeks, and increased a little with immersion time, and 316L SS released about 3.5 ng/ml nickel, but SR-3Mo released a large amount of nickel, which increased with immersion time. The study demonstrated that SR-50A, SR-6DX, and SFSS have high corrosion resistance and mild or no cytotoxicity, due to the passive film enhanced by synergistic effect of Mo + N or by high addition effect of Cr + W. All super stainless steels showed very low cytotoxicity regardless of their nickel contents, although SR-3Mo was found to be relatively cytotoxic. From these studies, these steels are considered suitable for orthodontic applications.

Biocompatible Materials↗

Inhibiting sulfate-reducing bacteria in biofilms on steel with antimicrobial peptides generated in situ.

In batch and continuous fermentations, the reduction in corrosion of SAE 1018 mild steel and 304 stainless steel caused by inhibition of the reference sulfate-reducing bacterium (SRB) Desulfovibrio vulgaris by a protective, antimicrobial-producing Bacillus brevis biofilm was investigated. The presence of D. vulgaris produced a thick black precipitate on mild steel and a higher corrosion rate in batch cultures than that seen in a mono-culture of non-antimicrobial-producing Pseudomonas fragi K upon the addition of SRB to the aerobic P. fragi K biofilm. In continuous reactors, the polarization resistance RP decreased for stainless stell and increased for mild steel upon the addition of SRB to a P. fragi K biofilm. Addition of either 200 micrograms/ml ampicillin, chloramphenicol, or ammonium molybdate to batch and continuous reactors after SRB had colonized the metal was ineffective in killing SRB, as inferred from the lack of change in both Rp and the impedance spectra. However, when ampicillin was added prior to SRB colonization, the growth of SRB was completely inhibited on stainless steel in continuous reactors. Prior addition of ampicillin was only able to delay the growth of SRB on mild steel in continuous reactors. External addition of the purified peptide antimicrobial agent gramicidin S prior to the addition of SRB also inhibited the growth of SRB on stainless steel in continuous reactors, and the SRB were also inhibited on stainless steel in both batch and continuous reactors by producing gramicidin S in situ in a protective biofilm when the gramicidin-S-overproducing strain Bacillus brevis 18 was used.

Anti-Bacterial Agents↗